Sunteți pe pagina 1din 24

GSM BSS

GBSS15.0
Access Control Feature Parameter
Description
Issue 01
Date 2013-05-06
HUAWEI TECHNOLOGIES CO., LTD.


Copyright Huawei Technologies Co., Ltd. 2013. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or representations
of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.






Huawei Technologies Co., Ltd.
Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: support@huawei.com
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
i
Contents
1 About This Document..................................................................................................................1
1.1 Scope..............................................................................................................................................................................1
1.2 Intended Audience..........................................................................................................................................................1
1.3 Change History...............................................................................................................................................................1
2 Overview.........................................................................................................................................3
2.1 Introduction....................................................................................................................................................................3
2.2 Feature Support by NE...................................................................................................................................................3
3 Principles.........................................................................................................................................4
4 Strategy............................................................................................................................................5
5 Engineering Guidelines...............................................................................................................7
5.1 Deploying Access Control Class (ACC)........................................................................................................................7
5.1.1 Deployment Requirements..........................................................................................................................................7
5.1.2 Feature Activation.......................................................................................................................................................7
5.1.3 Activation Observation................................................................................................................................................9
5.1.4 Deactivation...............................................................................................................................................................10
6 Parameters.....................................................................................................................................12
7 Counters........................................................................................................................................19
8 Glossary.........................................................................................................................................20
9 Reference Documents.................................................................................................................21
GSM BSS
Access Control Feature Parameter Description Contents
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
ii
1 About This Document
1.1 Scope
This document describes the GBFD-511002 Access Control Class(ACC) feature, including its
concept, implementation, and technical principles.
1.2 Intended Audience
This document is intended for:
l Personnel who need to understand the ACC feature
l Personnel who work with Huawei GSM products
1.3 Change History
This section provides information about the changes in different document versions.
There are two types of changes, which are defined as follows:
l Feature change: refers to a change in the ACC feature of a specific product version.
l Editorial change: refers to a change in wording or the addition of information that was not
described in the earlier version.
Document Issues
The document issue is as follows:
l 01 (2013-05-06)
l Draft A (2013-02-27)
01 (2013-05-06)
This is the first commercial release of GBSS15.0.
Compared with Draft A (2013-02-27), Issue 01 (2013-05-06) has no change.
GSM BSS
Access Control Feature Parameter Description 1 About This Document
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
1
Draft A (2013-02-27)
This is a draft.
Compared with Issue 01 (2012-04-28) of GBSS14.0, Draft A (2013-02-27) of GBSS15.0
incorporates the changes described in the following table.
Change Type Change Description Parameter Change
Feature change Added descriptions about the
BSC6910 and eGBTS.
Added section "2.2 Feature
Support by NE."
None
Editorial change Added chapter "5
Engineering Guidelines."
None
GSM BSS
Access Control Feature Parameter Description 1 About This Document
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
2
2 Overview
2.1 Introduction
With the ACC feature, the BSC can control the number of MSs accessing the network at a certain
time by allowing only the MSs of a certain ACC class to access the network. This avoids the
base station subsystem (BSS) overload or mobile switching center (MSC) overload caused by
the simultaneous access of numerous MSs. In addition, the ACC feature uses a sliding window
mechanism to enable the MSs of all ACC classes to access the network. This way, radio services
are available for all MSs, especially in emergencies.
In emergencies such as during natural disasters, the traffic in the network increases sharply. The
traffic may increase to an extent that exceeds the network capacity. In such a case, subscribers
have difficulties in making calls, and the radio network may be down. To resolve this problem,
the ACC feature is introduced. This feature controls the number of MSs that access the network
in emergencies by allowing only the MSs of certain ACC classes to access the network, ensuring
that the radio network works properly.
2.2 Feature Support by NE
Table 2-1 Feature support by NE
Feature BSC6900 BSC6910 GBTS eGBTS
Access Control
Class(ACC)


NOTE
indicates that the NE supports this feature. indicates that the NE does not support this feature.
GSM BSS
Access Control Feature Parameter Description 2 Overview
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
3
3 Principles
When registered in a GSM network, an MS is assigned a common ACC class, ranging from
Class 0 to Class 9, Class 10 to emergency call, or a special ACC class, ranging from Class 11
to Class 15. The BSC indicates in the system messages the access classes of the MSs that are
allowed to access the network. The ACC feature uses a window sliding mechanism to allow
only the MSs of a certain ACC class to access the network at a certain time. The size and speed
of the sliding window is specified in the ACCCTRLPY(GSM BSC6900,GSM BSC6910)
parameter.
There are 16 ACC classes. Class 0 to Class 9 are common classes and are specified for common
voice and data services; Class 10 to emergency; Class 11 to Class 15 are special classes and are
specified for services such as emergency call. Currently, the BSC controls only the access of
MSs of Class 0 to Class 9. The ACC feature is implemented by the MS, BSS, and MSC/VLR
as a joint effort. The principles are as follows:
1. The access class of MSs of special classes is set to a high priority.
2. When an MSC/VLR is excessively overloaded and the access side of the MSC/VLR is
congested, the BSC under the MSC/VLR controls the access of the MSs in certain cells.
Only the MSs having high access priorities and certain MSs of common classes use the
random access channel (RACH) to access the radio network.
3. The BSC broadcasts the class in which MSs are allowed to access a network.
4. The MS matches its class information stored in the SIM card and that in the broadcast
information. If allowed, the MS uses the RACH to access the radio network. Otherwise,
the access of the MS is barred.
GSM BSS
Access Control Feature Parameter Description 3 Principles
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
4
4 Strategy
When ACCCTRLEN(GSM BSC6900,GSM BSC6910) is set to YES(Yes), the ACC feature is
enabled in a cell. After the feature is enabled, the BSC determines the MSs allowed to access
the network by sending system information (SI) that carries the ACC classes according to the
policy specified by ACCCTRLPY(GSM BSC6900,GSM BSC6910). If the current ACC policy
is changed or the MS uses another policy, the BSC sends SI that carries the ACC classes again.
The value range of ACCINDEX(GSM BSC6900,GSM BSC6910) is 0 to 31. Each control policy
is configured with ACCWPOS(GSM BSC6900,GSM BSC6910), ACCWSIZE(GSM
BSC6900,GSM BSC6910), and ACCWSP(GSM BSC6900,GSM BSC6910). ACCWSP(GSM
BSC6900,GSM BSC6910) specifies the sliding speed of the ACC sliding window, ACCWPOS
(GSM BSC6900,GSM BSC6910) specifies the starting point of the ACC sliding window, and
Access Control Window Size specifies the ACC sliding window size in an access control policy.
MSs of the ACC access classes that are specified in the sliding window are not allowed to access
the network. For example, if ACCINDEX(GSM BSC6900,GSM BSC6910) is set to 1,
ACCWPOS(GSM BSC6900,GSM BSC6910) to 0, ACCWSIZE(GSM BSC6900,GSM
BSC6910) to 2, and ACCWSP(GSM BSC6900,GSM BSC6910) to 120s, the MSs of Class 0
and Class 1 are forbidden to access the network during the first period (first 120s); the MSs of
Class 2 and Class 3 are forbidden to access the network during the second period (second 120s),
and the MSs of other classes . Figure 4-1 shows the time assignment principle.
GSM BSS
Access Control Feature Parameter Description 4 Strategy
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
5
Figure 4-1 Assignment of ACC classes by time
The description of Figure 4-1 is as follows:
The sliding window mechanism allows the BSC to send ACC classes based on ACCWSP(GSM
BSC6900,GSM BSC6910) and ACCWSIZE(GSM BSC6900,GSM BSC6910). In this manner,
MSs of different ACC classes can access the radio network and radio services are available for
all MSs even in emergencies.
GSM BSS
Access Control Feature Parameter Description 4 Strategy
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
6
5 Engineering Guidelines
5.1 Deploying Access Control Class (ACC)
5.1.1 Deployment Requirements
Table 5-1 Deployment requirements
Aspect Requirement
Related features None
BSC None
BTS None
GSM networking None
MS MSs and their subscriber identity module (SIM) cards meet
the ACC-related requirements specified by GSM protocols.
MSC None
License The license controlling this feature has been activated. For
details on how to activate the license, see License
Management Feature Parameter Description. For details
about license items, see License Control Item Description.
Others None

5.1.2 Feature Activation
Using the LMT
On the BSC LMT, perform the following steps:
GSM BSS
Access Control Feature Parameter Description 5 Engineering Guidelines
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
7
Step 1 Run the ADD BSCACCCTRLP command with Access Control Policy Index, Access Control
Window Size, Starting Point of the Access Control Window, and Sliding Speed of the Access
Control Window set as required.
NOTE
A maximum of 32 access control policies can be set. To set multiple access control policies, perform this
step for multiple times.
If an access control policy is enabled and the BSC has sent the system information (SI) to MSs,
the access of the MSs of classes 10 to 15 is not affected by the configuration of the access control
policy.
Step 2 Run the SET GCELLCCBASIC command with Access Control Allowed set to YES(Yes)
and Access Control Policy set to the value of Access Control Policy Index specified in step
1.
----End
MML Examples
//Activating Access Control Class (ACC)
ADD BSCACCCTRLP: ACCINDEX=0;
SET GCELLCCBASIC: IDTYPE=BYID, CELLID=0, ACCCTRLEN=YES,
ACCCTRLPY=0;
Using the CME
NOTE
When configuring the Access Control Class (ACC) feature on the CME, you must perform a single
configuration first, and then perform batch modifications if required.
You must perform a single configuration for a parameter before batch modifications of the parameter. You
are advised to perform batch modifications before logging out of the parameter setting interface.
Step 1 Configure a single object on the CME. (CME single configuration)
Set parameters on the CME configuration interface according to the operation sequence
described in Table 5-2. For the method of performing the CME single configuration, see the
CME Single Configuration Operation Guide.
Step 2 (Optional) Modify objects in batches on the CME. (CME batch modification center)
To modify objects, such as BSCs, BTSs, cells, and TRXs, in batches, click the icon on the
CME configuration interface to start the batch modification wizard. For the method of
performing batch modifications through the CME batch modification center, press F1 on the
wizard interface to obtain online help.
----End
GSM BSS
Access Control Feature Parameter Description 5 Engineering Guidelines
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
8
Table 5-2 Configuring parameters on the CME
SN Managed
Object (MO)
NE Paramet
er Name
Parameter
ID
Supports
CME
Batch
Modificati
on Center
1 BSCACCCTR
LP
NOTE
A maximum of
32 access
control
policies can be
set. To set
multiple access
control
policies,
configure this
MO for
multiple times.
If an access
control policy
is enabled and
the BSC has
sent the SI to
MSs, the
access of the
MSs of classes
10 to 15 is not
affected by the
configuration
of the access
control policy.
BSC6900/BSC6910 Access
Control
Policy
Index
ACCINDEX Yes
Access
Control
Window
Size
ACCWSIZE
Starting
Point of
the
Access
Control
Window
ACCWPOS
Sliding
Speed of
the
Access
Control
Window
ACCWSP
2 GCELLCCBA
SIC
BSC6900/BSC6910 Access
Control
Allowed
ACCCTRLE
N
Yes
Access
Control
Policy
ACCCTRLP
Y

5.1.3 Activation Observation
On the BSC LMT, perform the following steps:
Step 1 Run the LST GCELLCCBASIC command to query the values of Access Control Allowed
and Access Control Policy.
Expected result: The value of Access Control Allowed is Yes and Access Control Policy is
specified.
Step 2 Run the LST BSCACCCTRLP command to query the values of Access Control Window
Size, Starting Point of the Access Control Window, and Sliding Speed of the Access Control
Window.
GSM BSS
Access Control Feature Parameter Description 5 Engineering Guidelines
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
9
Expected result: The values of Access Control Window Size, Starting Point of the Access
Control Window, and Sliding Speed of the Access Control Window are the configured ones.
Step 3 Trace radio signaling link (RSL) messages on the Abis interface.
NOTE
The access-control-class field in the RACH Control Parameters information element (IE) is called the ACC
field. The ACC field contains two octets and is 16 bits in length. Each bit indicates a level of SIM users
and its value is 0 or 1. When a bit is 0, the SIM users of the corresponding level are allowed to access the
network. When a bit is 1, the SIM users of the corresponding level are forbidden to access the network.
Expected result: The SI contains the RACH Control Parameters IE, and the value of the bits in
the ACC field of the RACH Control Parameters IE is 1 from the starting point onwards within
the sliding window range.
Step 4 Use an MS to make a call within the period specified in step 1.
Expected result: If the level of the SIM card of the MS falls into the forbidden levels, the MS
cannot access the network. If the level of the SIM card falls into the allowed levels, the MS can
access the network properly.
----End
5.1.4 Deactivation
Using the LMT
On the BSC LMT, run the SET GCELLCCBASIC command to disable the ACC feature in a
cell. In this step, set Access Control Allowed to NO(No).
MML Examples
//Deactivating Access Control Class (ACC)
SET GCELLCCBASIC: IDTYPE=BYID, CELLID=0, ACCCTRLEN=NO;
Using the CME
Step 1 Configure a single object on the CME. (CME single configuration)
Set parameters on the CME configuration interface according to the operation sequence
described in Table 5-3. For the method of performing the CME single configuration, see the
CME Single Configuration Operation Guide.
Step 2 (Optional) Modify objects in batches on the CME. (CME batch modification center)
To modify objects, such as BSCs, BTSs, cells, and TRXs, in batches, click the icon on the
CME configuration interface to start the batch modification wizard. For the method of
performing batch modifications through the CME batch modification center, press F1 on the
wizard interface to obtain online help.
----End
GSM BSS
Access Control Feature Parameter Description 5 Engineering Guidelines
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
10
Table 5-3 Configuring the parameter on the CME
SN MO NE Parameter
Name
Parameter
ID
Supports
CME Batch
Modificati
on Center
1 GCELLCCB
ASIC
BSC6900/
BSC6910
Access
Control
Allowed
ACCCTRLE
N
Yes
GSM BSS
Access Control Feature Parameter Description 5 Engineering Guidelines
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
11
6 Parameters
Table 6-1 Parameter description
Parameter ID NE MML
Command
Feature ID Feature Name Description
ACCCTRLPY BSC6900 SET
GCELLCCBA
SIC
GBFD-511002 Access Control
Class (ACC)
Meaning:This
parameter
specifies the
index of the
access control
policy that is
used in a cell.
GUI Value
Range:0~31
Unit:None
Actual Value
Range:0~31
Default
Value:None
ACCCTRLPY BSC6910 SET
GCELLCCBA
SIC
GBFD-511002 Access Control
Class (ACC)
Meaning:This
parameter
specifies the
index of the
access control
policy that is
used in a cell.
GUI Value
Range:0~31
Unit:None
Actual Value
Range:0~31
Default
Value:None
GSM BSS
Access Control Feature Parameter Description 6 Parameters
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
12
Parameter ID NE MML
Command
Feature ID Feature Name Description
ACCCTRLEN BSC6900 SET
GCELLCCBA
SIC
GBFD-511002 Access Control
Class (ACC)
Meaning:This
parameter
specifies
whether the
access control
function is
enabled in a cell.
When the
function is
enabled, the
BSC determines
which MSs in
the cell to be
connected to the
network by
sending the
ACC classes
through system
messages
according to the
specified policy
in Access
Control Policy.
GUI Value
Range:NO(No),
YES(Yes)
Unit:None
Actual Value
Range:NO, YES
Default
Value:NO(No)
GSM BSS
Access Control Feature Parameter Description 6 Parameters
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
13
Parameter ID NE MML
Command
Feature ID Feature Name Description
ACCCTRLEN BSC6910 SET
GCELLCCBA
SIC
GBFD-511002 Access Control
Class (ACC)
Meaning:This
parameter
specifies
whether the
access control
function is
enabled in a cell.
When the
function is
enabled, the
BSC determines
which MSs in
the cell to be
connected to the
network by
sending the
ACC classes
through system
messages
according to the
specified policy
in Access
Control Policy.
GUI Value
Range:NO(No),
YES(Yes)
Unit:None
Actual Value
Range:NO, YES
Default
Value:NO(No)
GSM BSS
Access Control Feature Parameter Description 6 Parameters
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
14
Parameter ID NE MML
Command
Feature ID Feature Name Description
ACCINDEX BSC6900 ADD
BSCACCCTR
LP
MOD
BSCACCCTR
LP
RMV
BSCACCCTR
LP
GBFD-511002 Access Control
Class (ACC)
Meaning:This
parameter
specifies the
index of an
access control
(ACC) policy. It
is used to
identify an ACC
policy.
GUI Value
Range:0~31
Unit:None
Actual Value
Range:0~31
Default
Value:None
ACCINDEX BSC6910 ADD
BSCACCCTR
LP
MOD
BSCACCCTR
LP
RMV
BSCACCCTR
LP
GBFD-511002 Access Control
Class (ACC)
Meaning:This
parameter
specifies the
index of an
access control
(ACC) policy. It
is used to
identify an ACC
policy.
GUI Value
Range:0~31
Unit:None
Actual Value
Range:0~31
Default
Value:None
GSM BSS
Access Control Feature Parameter Description 6 Parameters
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
15
Parameter ID NE MML
Command
Feature ID Feature Name Description
ACCWPOS BSC6900 ADD
BSCACCCTR
LP
MOD
BSCACCCTR
LP
GBFD-511002 Access Control
Class (ACC)
Meaning:This
parameter is
used to specify
the starting point
of the ACC
sliding window
in an access
control policy.
GUI Value
Range:0~9
Unit:None
Actual Value
Range:0~9
Default Value:0
ACCWPOS BSC6910 ADD
BSCACCCTR
LP
MOD
BSCACCCTR
LP
GBFD-511002 Access Control
Class (ACC)
Meaning:This
parameter is
used to specify
the starting point
of the ACC
sliding window
in an access
control policy.
GUI Value
Range:0~9
Unit:None
Actual Value
Range:0~9
Default Value:0
GSM BSS
Access Control Feature Parameter Description 6 Parameters
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
16
Parameter ID NE MML
Command
Feature ID Feature Name Description
ACCWSIZE BSC6900 ADD
BSCACCCTR
LP
MOD
BSCACCCTR
LP
GBFD-511002 Access Control
Class (ACC)
Meaning:This
parameter is
used to specify
the ACC sliding
window size in
an access
control policy.
MSs of the ACC
access classes
that are
specified in the
sliding window
are not allowed
to access the
network.
GUI Value
Range:1~10
Unit:None
Actual Value
Range:1~10
Default Value:2
ACCWSIZE BSC6910 ADD
BSCACCCTR
LP
MOD
BSCACCCTR
LP
GBFD-511002 Access Control
Class (ACC)
Meaning:This
parameter is
used to specify
the ACC sliding
window size in
an access
control policy.
MSs of the ACC
access classes
that are
specified in the
sliding window
are not allowed
to access the
network.
GUI Value
Range:1~10
Unit:None
Actual Value
Range:1~10
Default Value:2
GSM BSS
Access Control Feature Parameter Description 6 Parameters
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
17
Parameter ID NE MML
Command
Feature ID Feature Name Description
ACCWSP BSC6900 ADD
BSCACCCTR
LP
MOD
BSCACCCTR
LP
GBFD-511002 Access Control
Class (ACC)
Meaning:This
parameter is
used to specify
the sliding speed
of the ACC
sliding window
in an access
control policy.
GUI Value
Range:15~7200
Unit:s
Actual Value
Range:15~7200
Default Value:
120
ACCWSP BSC6910 ADD
BSCACCCTR
LP
MOD
BSCACCCTR
LP
GBFD-511002 Access Control
Class (ACC)
Meaning:This
parameter is
used to specify
the sliding speed
of the ACC
sliding window
in an access
control policy.
GUI Value
Range:15~7200
Unit:s
Actual Value
Range:15~7200
Default Value:
120
GSM BSS
Access Control Feature Parameter Description 6 Parameters
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
18
7 Counters
There are no specific counters associated with this feature.
GSM BSS
Access Control Feature Parameter Description 7 Counters
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
19
8 Glossary
For the acronyms, abbreviations, terms, and definitions, see the Glossary.
GSM BSS
Access Control Feature Parameter Description 8 Glossary
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
20
9 Reference Documents
There are no specific reference documents associated with this feature.
GSM BSS
Access Control Feature Parameter Description 9 Reference Documents
Issue 01 (2013-05-06) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
21

S-ar putea să vă placă și