Documente Academic
Documente Profesional
Documente Cultură
Note: Before using this information and the product it supports, read the general information in Getting help and
technical assistance, on page 489, Notices on page 493, the Warranty Information document, and the Safety Information and
Environmental Notices and User Guide documents on the IBM Documentation CD.
Twenty-seventh Edition (October 2012)
Copyright IBM Corporation 2012.
US Government Users Restricted Rights Use, duplication or disclosure restricted by GSA ADP Schedule Contract
with IBM Corp.
Contents
Chapter 1. Introduction . . . . . . . . 1
Before you begin . . . . . . . . . . . . . 2
Accessibility features for the BladeCenter
management module . . . . . . . . . . . 2
Chapter 2. Using the command-line
interface . . . . . . . . . . . . . . 5
Command-line interface guidelines . . . . . . . 5
Selecting the command target. . . . . . . . . 6
Commands and user authority . . . . . . . . 8
Cabling the management module . . . . . . . 12
Networked connection. . . . . . . . . . 13
Direct connection . . . . . . . . . . . 13
Serial connection . . . . . . . . . . . 14
Starting the command-line interface . . . . . . 14
IPv6 addressing for initial connection. . . . . 15
Telnet connection . . . . . . . . . . . 16
Serial connection . . . . . . . . . . . 17
Secure Shell (SSH) connection . . . . . . . 18
BladeCenter unit configuration . . . . . . . . 20
Configuring the management module . . . . . 21
Starting an SOL session . . . . . . . . . . 22
Ending an SOL session . . . . . . . . . . 23
Chapter 3. Command reference . . . . 25
Alphabetic command list . . . . . . . . . . 25
Command list by function . . . . . . . . . 27
Command syntax . . . . . . . . . . . . 29
accseccfg command. . . . . . . . . . . 30
advfailover command . . . . . . . . . . 40
airfilter command (BladeCenter S only) . . . . 42
alarm command (BladeCenter T and HT only). . 43
alertcfg command . . . . . . . . . . . 51
alertentries command . . . . . . . . . . 53
autoftp command . . . . . . . . . . . 60
baydata command . . . . . . . . . . . 63
bofm command . . . . . . . . . . . . 66
boot command . . . . . . . . . . . . 72
bootmode command . . . . . . . . . . 74
bootseq command . . . . . . . . . . . 75
buildidcfg command . . . . . . . . . . 80
chconfig command . . . . . . . . . . . 87
chlog command . . . . . . . . . . . . 93
chmanual command . . . . . . . . . . 95
cin command. . . . . . . . . . . . . 97
cinstatus command . . . . . . . . . . 102
clear command . . . . . . . . . . . . 103
clearlog command. . . . . . . . . . . 105
clock command. . . . . . . . . . . . 106
config command . . . . . . . . . . . 111
console command . . . . . . . . . . . 115
dhcpinfo command . . . . . . . . . . 117
displaylog command . . . . . . . . . . 119
displaysd command . . . . . . . . . . 124
dns command . . . . . . . . . . . . 126
env (environment) command . . . . . . . 131
ethoverusb command. . . . . . . . . . 137
eventinfo command . . . . . . . . . . 138
events command . . . . . . . . . . . 140
exit command . . . . . . . . . . . . 143
feature command . . . . . . . . . . . 144
files command . . . . . . . . . . . . 147
fuelg command. . . . . . . . . . . . 149
groups command . . . . . . . . . . . 159
health command . . . . . . . . . . . 163
help command . . . . . . . . . . . . 166
history command . . . . . . . . . . . 168
identify (location LED) command . . . . . 169
ifconfig command . . . . . . . . . . . 171
info (configuration information) command . . 203
iocomp command . . . . . . . . . . . 206
kvm (keyboard, video, mouse) command . . . 208
ldapcfg command . . . . . . . . . . . 210
led command . . . . . . . . . . . . 220
list (system physical configuration) command 225
mcad command . . . . . . . . . . . 227
modactlog command . . . . . . . . . . 228
monalerts command . . . . . . . . . . 229
mt (media tray) command . . . . . . . . 239
nat command . . . . . . . . . . . . 241
ntp (network time protocol) command . . . . 245
ping command . . . . . . . . . . . . 248
pmpolicy command . . . . . . . . . . 251
portcfg command . . . . . . . . . . . 253
ports command. . . . . . . . . . . . 255
power command . . . . . . . . . . . 272
rdoc command . . . . . . . . . . . . 278
read command . . . . . . . . . . . . 280
remacccfg command . . . . . . . . . . 283
remotechassis command. . . . . . . . . 285
reset command . . . . . . . . . . . . 288
scale command. . . . . . . . . . . . 293
sddump command . . . . . . . . . . 301
sdemail command. . . . . . . . . . . 303
security command. . . . . . . . . . . 305
service command . . . . . . . . . . . 306
shutdown command . . . . . . . . . . 308
slp command . . . . . . . . . . . . 309
smtp command. . . . . . . . . . . . 311
snmp command . . . . . . . . . . . 314
sol (serial over LAN) command . . . . . . 330
sshcfg command . . . . . . . . . . . 337
sslcfg command . . . . . . . . . . . 339
syslog command . . . . . . . . . . . 349
tcpcmdmode command . . . . . . . . . 353
telnetcfg (Telnet configuration) command . . . 356
temps command . . . . . . . . . . . 357
trespass command. . . . . . . . . . . 358
uicfg command. . . . . . . . . . . . 361
update (update firmware) command . . . . 365
uplink (management module failover) command 375
Copyright IBM Corp. 2012 iii
users command . . . . . . . . . . . 379
vlan command . . . . . . . . . . . . 402
volts command. . . . . . . . . . . . 412
write command . . . . . . . . . . . 413
zonecfg command . . . . . . . . . . . 415
Chapter 4. Error messages . . . . . 419
Common errors . . . . . . . . . . . . 421
accseccfg command errors . . . . . . . . . 423
advfailover command errors . . . . . . . . 424
alarm command errors . . . . . . . . . . 425
alertcfg command errors. . . . . . . . . . 426
alertentries command errors . . . . . . . . 426
autoftp command errors. . . . . . . . . . 427
baydata command errors . . . . . . . . . 427
bofm command errors . . . . . . . . . . 428
boot command errors. . . . . . . . . . . 429
bootmode command errors . . . . . . . . . 429
bootseq command errors . . . . . . . . . 430
buildidcfg command errors. . . . . . . . . 430
chconfig command errors . . . . . . . . . 431
chlog command errors . . . . . . . . . . 432
chmanual command errors . . . . . . . . . 433
cin command errors . . . . . . . . . . . 433
clear command errors . . . . . . . . . . 435
clearlog command errors . . . . . . . . . 435
clock command errors . . . . . . . . . . 435
config command errors . . . . . . . . . . 436
console command errors. . . . . . . . . . 437
dhcpinfo command errors . . . . . . . . . 438
displaylog command errors. . . . . . . . . 438
displaysd command errors . . . . . . . . . 439
dns command errors . . . . . . . . . . . 440
env command errors . . . . . . . . . . . 440
ethoverusb command errors . . . . . . . . 440
eventinfo command errors . . . . . . . . . 441
events command errors . . . . . . . . . . 441
exit command errors . . . . . . . . . . . 442
feature command errors . . . . . . . . . . 442
files command errors . . . . . . . . . . . 444
fuelg command errors . . . . . . . . . . 445
groups command errors . . . . . . . . . . 448
health command errors . . . . . . . . . . 448
help command errors. . . . . . . . . . . 449
history command errors . . . . . . . . . . 449
identify command errors . . . . . . . . . 449
ifconfig command errors . . . . . . . . . 450
info command errors . . . . . . . . . . . 454
iocomp command errors. . . . . . . . . . 455
kvm command errors. . . . . . . . . . . 455
ldapcfg command errors. . . . . . . . . . 455
led command errors . . . . . . . . . . . 456
list command errors . . . . . . . . . . . 457
mcad command errors . . . . . . . . . . 457
modactlog command errors . . . . . . . . 457
monalerts command errors . . . . . . . . . 457
monalertsleg command errors . . . . . . . . 458
mt command errors . . . . . . . . . . . 458
nat command errors . . . . . . . . . . . 458
ntp command errors . . . . . . . . . . . 459
ping command errors . . . . . . . . . . 459
pmpolicy command errors . . . . . . . . . 460
portcfg command errors . . . . . . . . . . 460
ports command errors . . . . . . . . . . 460
power command errors . . . . . . . . . . 462
rdoc command errors. . . . . . . . . . . 462
read command errors. . . . . . . . . . . 463
remacccfg command errors . . . . . . . . . 464
remotechassis command errors . . . . . . . 464
reset command errors . . . . . . . . . . 465
scale command errors . . . . . . . . . . 465
sddump command errors . . . . . . . . . 466
sdemail command errors . . . . . . . . . 467
security command errors . . . . . . . . . 467
service command errors . . . . . . . . . . 467
shutdown command errors . . . . . . . . . 468
slp command errors . . . . . . . . . . . 468
smtp command errors . . . . . . . . . . 468
snmp command errors . . . . . . . . . . 469
sol command errors . . . . . . . . . . . 470
sshcfg command errors . . . . . . . . . . 471
sslcfg command errors . . . . . . . . . . 472
syslog command errors . . . . . . . . . . 474
tcpcmdmode command errors . . . . . . . . 475
telnetcfg command errors . . . . . . . . . 475
temps command errors . . . . . . . . . . 476
thres command errors . . . . . . . . . . 476
trespass command errors . . . . . . . . . 476
uicfg command errors . . . . . . . . . . 477
update command errors . . . . . . . . . . 478
uplink command errors . . . . . . . . . . 480
users command errors . . . . . . . . . . 481
vlan command errors. . . . . . . . . . . 485
volts command errors . . . . . . . . . . 486
write command errors . . . . . . . . . . 486
zonecfg command errors . . . . . . . . . 487
Appendix. Getting help and technical
assistance. . . . . . . . . . . . . 489
Before you call . . . . . . . . . . . . . 489
Using the documentation . . . . . . . . . 490
Getting help and information from the World Wide
Web . . . . . . . . . . . . . . . . 490
How to send DSA data to IBM . . . . . . . 490
Creating a personalized support web page . . . 490
Software service and support . . . . . . . . 490
Hardware service and support . . . . . . . 491
IBM Taiwan product service . . . . . . . . 491
Notices . . . . . . . . . . . . . . 493
Trademarks . . . . . . . . . . . . . . 493
Important notes . . . . . . . . . . . . 494
Particulate contamination . . . . . . . . . 495
Documentation format . . . . . . . . . . 496
Telecommunication regulatory statement . . . . 496
Electronic emission notices . . . . . . . . . 496
Federal Communications Commission (FCC)
statement. . . . . . . . . . . . . . 496
Industry Canada Class A emission compliance
statement. . . . . . . . . . . . . . 497
iv IBM BladeCenter Advanced Management Module: Command-Line Interface Reference Guide
Avis de conformit la rglementation
d'Industrie Canada . . . . . . . . . . 497
Australia and New Zealand Class A statement 497
European Union EMC Directive conformance
statement. . . . . . . . . . . . . . 497
Germany Class A statement . . . . . . . 498
Japan VCCI Class A statement. . . . . . . 499
Korea Communications Commission (KCC)
statement. . . . . . . . . . . . . . 499
Russia Electromagnetic Interference (EMI) Class
A statement . . . . . . . . . . . . . 499
People's Republic of China Class A electronic
emission statement . . . . . . . . . . 499
Taiwan Class A compliance statement . . . . 499
Index . . . . . . . . . . . . . . . 501
Contents v
vi IBM BladeCenter Advanced Management Module: Command-Line Interface Reference Guide
Chapter 1. Introduction
This topic provides a short introduction to the BladeCenter advanced management
module command-line interface. Information about the command-line interface for
management modules other than the advanced management module is in a
separate document.
The IBM
BladeCenter
Windows
navigation keys.
Related accessibility information
You can view the publications for IBM BladeCenter in Adobe
Portable Document
Format (PDF) using the Adobe Acrobat
,
and UNIX (see your operating-system documentation for information). The SSH
client of Red Hat Linux 8.0 Professional was used to test the command-line
interface.
v The SSH client of cygwin (see http://www.cygwin.com for information)
v Putty (see http://www.chiark.greenend.org.uk/~sgtatham/putty for
information)
The following table shows the types of encryption algorithms that are supported,
depending on the client software version that is being used.
Algorithm SSH version 2.0 clients
Public key exchange Diffie-Hellman-group 1-sha-1
Host key type DSA - 2048-bit
Bulk cipher algorithms 3-des-cbc or blowfish-cbc
MAC algorithms Hmac-sha1
14 IBM BladeCenter Advanced Management Module: Command-Line Interface Reference Guide
The following topics describe how to connect your system to the management
module to perform initial configuration of the BladeCenter unit. The management
module has the following default settings:
Note: The advanced management module does not have a fixed static IPv6 IP
address by default. For initial access to the advanced management module in an
IPv6 environment, users can either use the IPv4 IP address or the IPv6 link-local
address. See IPv6 addressing for initial connection for information about
determining IPv6 addressing for initial connection.
v IPv4 IP address: 192.168.70.125 (primary and secondary management module)
v IPv4 Subnet: 255.255.255.0
v User ID: USERID (all capital letters)
v Password: PASSW0RD (note the number zero, not the letter O, in PASSW0RD)
For IPv4, the system that you are connecting to the management module must be
configured to operate on the same subnet as the BladeCenter management module.
If the IP address of the management module is outside of your local domain, you
must change the Internet protocol properties on the system that you are
connecting.
Note: For advanced management modules, the available password options depend
on the password options that are configured for the BladeCenter unit.
IPv6 addressing for initial connection
When using IPv6 addressing, the only way to initially connect to the advanced
management module is by using the IPv6 link-local address.
The link-local address is a unique IPv6 address for the advanced management
module that is automatically generated based on its MAC address. It is of the
form: FE80::3BA7:94FF:FE07:CBD0.
The link-local address for the advanced management module can be determined in
one of the following ways:
v Some advanced management modules will list the link-local address on a label
that is attached to the advanced management module.
v If you are able to log in to the management module command-line interface
(CLI) using IPv4 addressing, the link-local address can be viewed using the
ifconfig command (see ifconfig command on page 171 for information).
v If you are able to log in to the management module web interface using IPv4
addressing, the link-local address can be viewed in the Primary Management
Module, IPv6 section of the MM Control Network Interfaces page (see the
BladeCenter Advanced Management Module User's Guide for information).
If the advanced management module does not have a label listing the link-local
address and you are unable to access the advanced management module using
IPv4, complete the following steps to calculate link-local address:
1. Write down the MAC address of the advanced management module. It is on a
label on the management module, below the IP reset button. The label reads
MMxxxxxxxxxxxx, where xxxxxxxxxxxx is the MAC address. For example,
39-A7-94-07-CB-D0
2. Split the MAC address into two parts and insert FF-FE in the middle. For
example,
39-A7-94-FF-FE-07-CB-D0
Chapter 2. Using the command-line interface 15
3. Convert the two hexadecimal digits at the left end of the string to binary. For
example,
v 39-A7-94-FF-FE-07-CB-D0
v 00111001-A7-94-FF-FE-07-CB-D0
4. Invert the value for bit 7 of the binary string. For example,
v 00111001-A7-94-FF-FE-07-CB-D0
v 00111011-A7-94-FF-FE-07-CB-D0
5. Convert the binary digits at the left end of the string back to hexadecimal. For
example,
v 00111011-A7-94-FF-FE-07-CB-D0
v 3B-A7-94-FF-FE-07-CB-D0
6. Combine the hexadecimal digit pairs into 4-digit groups. For example,
v 3B-A7-94-FF-FE-07-CB-D0
v 3BA7-94FF-FE07-CBD0
7. Replace dash (-) separators with colon (:) separators. For example,
v 3BA7-94FF-FE07-CBD0
v 3BA7:94FF:FE07:CBD0
8. Add FE80:: to the left of the string. For example,
FE80::3BA7:94FF:FE07:CBD0
For a MAC address of 39-A7-94-07-CB-D0, the link-local address used for initial
IPv6 access is FE80::3BA7:94FF:FE07:CBD0.
Telnet connection
This topic tells you how to establish a Telnet session with the management
module.
To log on to the management module by using Telnet, complete the following
steps:
1. From a command-line prompt on the network-management workstation, type
telnet ip_address (where ip_address is the management module IP address),
and press Enter. For the first connection to the management module, use the
default IP address of the management module; if a new IP address has been
assigned to the management module, use that one instead.
Note: The factory-defined static IPv4 IP address is 192.168.70.125, the default
IPv4 subnet address is 255.255.255.0, and the default host name is
MMxxxxxxxxxxxx, where xxxxxxxxxxxx is the burned-in MAC address. The
MAC address is on a label on the management module, below the IP reset
button. See IPv6 addressing for initial connection on page 15 for information
about determining IPv6 addressing for initial connection.
2. At the login prompt, type the management-module user ID. At the password
prompt, type the management-module password. The user ID and password
are case sensitive and are the same as those that are used for
management-module web access. The default management-module user name
is USERID, and the default password is PASSW0RD (note the number zero, not
the letter O, in PASSW0RD).
The CLI command prompt is displayed. You can now enter commands for the
management module.
16 IBM BladeCenter Advanced Management Module: Command-Line Interface Reference Guide
Serial connection
You can set up a serial connection with the management module.
After you connect a serial cable from the management module to the client system,
complete the following steps:
1. Open a terminal session on the client system, and make sure that the serial port
settings for the client system match the settings for the serial port on the
management module. The default management-module serial port settings are
as follows:
v Baud rate (BPS): 57600
v Data bits: 8
v Parity: no parity
v Stop bits: 1
v Flow control: none
2. If any of the serial port settings for the client system were changed, reset the
management module (see the Installation Guide for your management module
for instructions).
3. At the login prompt, type the management-module user ID. At the password
prompt, type the management-module password. The user ID and password
are case sensitive and are the same as those that are used for
management-module web access. The default management-module user name
is USERID, and the default password is PASSW0RD (note the number zero, not
the letter O, in PASSW0RD).
The CLI command prompt is displayed. You can now enter commands for the
management module.
Chapter 2. Using the command-line interface 17
Secure Shell (SSH) connection
This topic tell you how to establish a Secure Shell (SSH) connection with the
management module.
To log on to the management module using SSH, complete the following steps:
1. Make sure that the SSH service on the network-management workstation is
enabled. See your operating-system documentation for instructions.
2. Make sure that the SSH server on the BladeCenter management module is
enabled. See the BladeCenter Advanced Management Module User's Guide for
instructions.
3. Start an SSH session to the management module, using the SSH client of your
choice. For example, if you are using the cygwin client, from a command
prompt on the network-management workstation, type ssh ip_address (where
ip_address is the management module IP address), and press Enter. For the first
connection to the management module, use the default IP address of the
management module; if a new IP address has been assigned to the
management module, use that one instead.
Note: The factory-defined static IPv4 IP address is 192.168.70.125, the default
IPv4 subnet address is 255.255.255.0, and the default host name is
MMxxxxxxxxxxxx, where xxxxxxxxxxxx is the burned-in MAC address. The
MAC address is on a label on the management module, below the IP reset
button. See IPv6 addressing for initial connection on page 15 for information
about determining IPv6 addressing for initial connection.
4. Type the management-module user ID when you are prompted. At the
password prompt, type the management-module password. The user ID and
password are case sensitive and are the same as those that are used for
management-module web access. The default management-module user name
is USERID, and the default password is PASSW0RD (note the number zero, not
the letter O, in PASSW0RD).
The CLI command prompt is displayed. You can now enter commands for the
management module.
Using the Secure Shell server
This topic tells you how to use the management module Secure Shell server.
The following SSH clients are available. Although some SSH clients have been
tested, support or nonsupport of any particular SSH client is not implied.
v The SSH clients that are distributed with operating systems such as Linux, AIX
,
and UNIX