Up to 32 digital and/or analogue external channels Non-volatile storage of channel calibration data Real Time clock with battery backup Up to 250 readings per channel with time stamp Variable logging modes include: Configurable linear times User configurable table times Reference channel incremental mode Automatic triggering of data logging including: Configurable delay time Value greater than a reference channel value Automatic stopping of data logging including: Configurable delay time Value greater than a reference channel value Automatic data collection Automatic test start and stop conditions On board large graphics display and keypad Menu driven command selection On screen live displays of graph and data tabulation Password protected configuration and calibration Built in transducer excitation supply RS232 serial interface for computer control Compatible with Windows based Clisp Studio software MPX3000 Data Logger MPX3000 with 4 channel digital junction box The VJ Tech MPX3000 is a state of the art data logger ideally suited to Soil Mechanics Laboratories and is simple to use and exible in operation. It can make a considerable improvement in laboratory productivity and cost effectiveness by automating test data collection, thus freeing the laboratory technician to perform other duties whilst the test is being conducted. The MPX3000 data logger is supplied as a fully congurable system, which can be upgraded by adding channel modules. Up to 32 internal analogue channels, in blocks of 8 channels can be housed within the logger itself and a further 32 channels can be added externally by daisy chaining junction boxes each with 4 analogue or digital channels. MPX3000 Data Logger
VJT3000 MPX3000 Data Logger (basic unit without input channels) VJT3000-8A 8 Channel Internal Analogue Module VJT3000-4D-MIT 4 Channel External Digital Dial Gauge Module Analogue Channel Input LSCT, Pressure or Load Cell Digital Channel Input Digital Dial Gauge Input (Load, Strain or Volume) Transducer Excitation Supply 10V DC Computer Interface RS232 Local Control via Keypad 20 keys Graphic Display 240x128 pixels Clock Battery backed real time clock Data Storage Up to 12000 readings for a single channel test Power Supply 110-240VAC, 50/60Hz, 1ph Dimensions (L x W x H) 380 x 450 x 150mm Weight (kg) 8kg Ordering Information VJT3000 specications Accessories Data Loggers and Interfaces Building Better Technology for the Civil Engineering Industry VJ Tech Limited Unit 1 io Trade Centre Deacon Way Reading RG30 6AZ Tel +44 118 945 3737 Fax +44 118 945 5209 Email info@vjtech.co.uk Web vjtech.co.uk Features On-board battery backed memory for data storage and calibration Real Time clock with battery backup Up to 250 readings per channel with time stamp Variable logging modes include:
Configurable linear times
User configurable table times
Reference channel incremental mode
Automatic triggering of data logging including:
Configurable delay time
Value greater than a reference channel value
Automatic stopping of data logging including:
Configurable delay time
Value greater than a reference channel value
Automatic data collection Viewable logged data Password protected configuration and calibration Transducer excitation supply of +/- 5V DC RS232 serial interface for computer control Optional Windows based CLISP Studio software MiniScanner2 Data Logger The VJ Tech MiniScanner2 is a simple to use four channel standalone data logging system specically designed for use in soil testing laboratories. Data collection for tests such as Triaxial, Oedometer and Shearbox can be fully automated. Conguring the system is made easy by using a 4x4 membrane keypad with associated LCD display. MiniScanner2 Data Logger The VJ Tech 4-Channel Digital Indicator PC Interface provides an interface for up to 4 Digital Dial Gauges to a USB port (via a USB to RS232 Interface) on a PC running Clisp Studio. Also available are a 4-Channel Analogue PC Interface, a single channel Digital or Analogue PC Interface and a dual Analogue/ Digital PC Interface. This has the same specication as the VJT1000A MiniScanner2 except that it is designed as a dedicated CBR/Marshall Data Logger. Therefore, the unit has the added feature of maximum hold but only requires 2 channels. Analogue and Digital PC Interfaces
Analogue Channel Input LSCT, Pressure or Load Cell Transducer Excitation Supply 10V DC Computer Interface RS232 Local Control via Keypad Yes Graphic Display Yes Power Supply 110-240VAC, 50/60Hz, 1ph Dimensions (L x W x H) 280 x 350 x 150mm Weight (kg) 6kg VJT1000A MiniScanner2 4 Channel Data Logger VJT1300A MiniScanner 2 Channel Data Logger for CBR/Marshall VJT1000A Specications Ordering Information
VJT1010-4D 4-Channel Digital Indicator PC Interface (includes USB to RS232 Converter, Power Supply and RS232 cable) VJT1010-4A 4-Channel Analogue transducer PC Interface (includes USB to RS232 Converter, Power Supply and RS232 cable) VJT1010-1D Single Channel Digital Indicator PC Interface (includes USB to RS232 Converter, Power Supply and RS232 cable) VJT1010-1A Single Channel Analogue transducer PC Interface (includes USB to RS232 Converter, Power Supply and RS232 cable) VJT1010-1AD 2 Channel (1 x Analogue, 1 x Digital) PC Interface (includes USB to RS232 Converter, Power Supply and RS232 cable) Analogue and Digital PC Interface Ordering Information 4-Channel Digital Indicator PC Interface