This document provides a preliminary electrical load list for the HVAC & R (heating, ventilation, air conditioning, and refrigeration) system accommodation on the Golar Hilli FLNG conversion project by Keppel Shipyard Ltd. It includes the electrical power requirements in kW for 22 different system equipment and components, such as air handling units, chillers, pumps, fans, air conditioners, and refrigeration systems. The power supply voltage, phase, and frequency are specified for each item, along with notes on power redundancy and operation details for some equipment.
This document provides a preliminary electrical load list for the HVAC & R (heating, ventilation, air conditioning, and refrigeration) system accommodation on the Golar Hilli FLNG conversion project by Keppel Shipyard Ltd. It includes the electrical power requirements in kW for 22 different system equipment and components, such as air handling units, chillers, pumps, fans, air conditioners, and refrigeration systems. The power supply voltage, phase, and frequency are specified for each item, along with notes on power redundancy and operation details for some equipment.
This document provides a preliminary electrical load list for the HVAC & R (heating, ventilation, air conditioning, and refrigeration) system accommodation on the Golar Hilli FLNG conversion project by Keppel Shipyard Ltd. It includes the electrical power requirements in kW for 22 different system equipment and components, such as air handling units, chillers, pumps, fans, air conditioners, and refrigeration systems. The power supply voltage, phase, and frequency are specified for each item, along with notes on power redundancy and operation details for some equipment.
System : HVAC & R System - Accommodation Subject : Electrical Load List - Preliminary Date : 9 th September 2014 Qty. Unit Electrical Power ( kW ) Power Supply Remark 2 set 70.00 440 V / 3 Ph / 60 Hz 2 x 100 % 2 set 2.50 440 V / 3 Ph / 60 Hz 2 x 100 % 2 set 11.00 440 V / 3 Ph / 60 Hz 2 x 100 %, 2 Unit may operate together. 2 x 5.5 kW 2 set 280.00 440 V / 3 Ph / 60 Hz 2 x 100 % 2 set 18.50 440 V / 3 Ph / 60 Hz 2 x 100 % 2 set 7.00 440 V / 3 Ph / 60 Hz 2 x 100 % 2 set 7.00 440 V / 3 Ph / 60 Hz 2 x 100 % 1 set 0.18 230 V / 1 Ph / 60 Hz 1 x 100 % 1 set 0.37 440 V / 3 Ph / 60 Hz 2 x 100 % 1 set 0.30 230 V / 1 Ph / 60 Hz 1 x 100 % 2 set 0.37 440 V / 3 Ph / 60 Hz 2 x 100 % 1 set 0.55 440 V / 3 Ph / 60 Hz 2 x 100 % Sr. No 1 2 3 4 5 System's Equipment / Component Descriprion Air Gandling Unit - Accommodation Air Gandling Unit - Galley Air Gandling Unit - ECR Chiller Unit Chilled Water Pump Air Conditioning Unit - LER ( Port ) 6 8.5 7 Air Conditioning Unit - LER ( Stbd. ) 8.3 Exhaust Air Fan - Smoking Room 4 th Poop Deck Exhaust Air Fan - Battery Room 5 th Poop Deck 3 th Poop Deck 8 Ventilation Fan 8.1 Exhaust Air Fan - Toilet 6 th Poop Deck 8.2 8.4 Exhaust Air Fan - Hospital Exhaust Air Fan - Laundry 7 th Poop Deck Client : Keppel Shipyard Ltd Project : Golar Hilli FLNG Conversion System : HVAC & R System - Accommodation Subject : Electrical Load List - Preliminary Date : 9 th September 2014 Qty. Unit Electrical Power ( kW ) Power Supply Remark Sr. No System's Equipment / Component Descriprion 1 set 0.30 230 V / 1 Ph / 60 Hz 1 x 100 % 2 set 1.50 440 V / 3 Ph / 60 Hz 2 x 50 % 1 set 0.75 440 V / 3 Ph / 60 Hz 1 x 100 % 1 set 0.37 440 V / 3 Ph / 60 Hz 1 x 100 % 1 set 0.55 440 V / 3 Ph / 60 Hz 1 x 100 % 2 set 5.50 440 V / 3 Ph / 60 Hz 2 x 100 % 1 lot 1.50 230 V / 1 Ph / 60 Hz 1 lot 65.00 230 V / 1 Ph / 60 Hz 2 sets 20.00 440 V / 3 Ph / 60 Hz 2 x 100 % 2 sets 12.00 440 V / 3 Ph / 60 Hz 2 x 100 % 1 set 12.50 440 V / 3 Ph / 60 Hz 1 x 100 % - Back Up Unit 1 set 12.50 440 V / 3 Ph / 60 Hz 1 x 100 % - Back Up Unit 8.8 13 14 Air Conditioning Unit - CCR Air Conditioning Unit - TR ( Mess Room ) Fresh Air Fan - Galley 8.7 Exhaust Air Fan - Galley 2 nd Poop Deck 8.6 Exhaust Air Fan - Smoking Room 1 st Poop Deck 8.9 Exhaust Air Fan - Laundry 10 Re-Heater Unit - Cabin 8.10 Exhaust Air Fan - Laundry 8.11 Exhaust Air Fan - Sanitary Spaces ( Port +Stbd ) 9 Dampers 11 Refrigeration System - Low Temperature Application 12 Refrigeration System - High Temperature Application