Sunteți pe pagina 1din 7

G+2, CP07B, TEMPORARY SITE OFFICE

(STRUCTURAL ANALYSIS DESIGN REPORT)


I. Basic Data:
Reference Height , Z = 9.60 m.
Structure Width = 29.00 m.
Wall height = 8.60 m.
Roof Slope = 3.55 deg.
Ze, for external pressure = m.
Terrain category = III see Table 4.1
II. Basic Wind Velocity, v
b
:
Equation 4.1
Directional factor, c
dir
= 1.00 recommended value=1.0, Note 2, section 4.2
Seasonal factor, c
season
= 1.00 recommended value=1.0, Note 3, section 4.2
Fundamental wind velocity = 35.00 m/s
v
b
= 35.00 m/s
III. Mean Wind Velocity, v
m
(z) :
Equation 4.3
Orography factor, c
o
(z) = 1.00 recommended value=1.0
Roughness factor, c
r
(z)
Equation 4.4
Roughness length, z
0
= 0.300 m.
Z
0
for terrain category II, z
o,II
= 0.05 m. see Table 4.1
= 5.00 m.
= 9.60 m.
= 9.60 m.
Equation 4.5
therefore, k
r
= 0.21539
therefore, c
r
(z) = 0.74648
v
m
(z) = 26.127 m/s
IV. Wind Turbulence, l
v
(z) :
Equation 4.7
turbulence factor, k
1
= 1.00 recommended value = 1.0, Note 2, section 4.4
therefore, l
v
(z) = 0.28854
lv(z) = k
1
/(c
o
(z) x ln(z/z
o
))
WIND LOADING AS PER EN 1991-1-4:2005
v
b
= c
dir
x c
season
x v
b,o
v
m
(z) = c
r
(z) x c
o
(z) x v
b
c
r
(z) = k
r
x ln(z/zo)
k
r
= 0.19 x (z
o
/z
o,II
)
0.07
Area with regular cover of vegetation or buildings or with isolated
obstacles with separations of maximum 20 obstacle heights (such as
villages, suburban terrain, permanent forest).
Zmin
Z
use, Z
Page 1 of 7
G+2, CP07B, TEMPORARY SITE OFFICE
(STRUCTURAL ANALYSIS DESIGN REPORT)
V. Basic Velocity Pressure, q
b
:
air density,

air
= 1.25
kg/m
3
recommended value = 1.25, Note 2, section 4.5
therefore, q
b
= 765.63
Pa (N/m
2
)
VI. Peak Velocity Pressure, q
p
:
Equation 4.8, Note 1, section 4.5
where,
l
v
(z) = 0.28854

air
= 1.25
kg/m
3
v
m
(z) = 26.127 m/s
therefore,
q
p
(z) = 1288.34
Pa (N/m
2
)
q
p
(z) = 1.288
kPa (kN/m
2
)
VII. COMPUTATION OF WIND PRESSURE TO VERTICAL WALLS:
ALONG X : h/d = LONGITUDINAL DIRECTION
2h =
b =
e =
DESIGN WIND PRESSURE
Kpa
ALONG Z : : h/d = TRANSVERSE DIRECTION
2h =
b =
e =
Kpa
q
b
= 1/2 x
air
x v
b
2
q
p
(z) = [1 + 7l
v
(z)] x 1/2 x
air
x v
m
2
(z)
ZONE D ZONE E
0.700
0.90 -0.39
-0.300
ZONE D ZONE E
0.711 -0.322
CORR. COEFF.
-0.35
PRESSURE 0.92 -0.41
0.85 0.85
DESIGN PRESSURE 0.77 -0.33
12.6
15.75
12.6
PRESSURE
DESIGN PRESSURE 0.78
0.123
Cpe, 10
Cpe, 10
CORR. COEFF. 0.85 0.85
0.331
e = smaller value of 2h or b:
12.3
15.75
12.3
e = smaller value of 2h or b:
Page 2 of 7
G+2, CP07B, TEMPORARY SITE OFFICE
(STRUCTURAL ANALYSIS DESIGN REPORT)
VIII. LOAD COMPUTATION
ALONG X :
2F 26.1 m
2
- Projected Area
FF 121.8 m
2
- Projected Area
Total = 147.9 m
2
- Total projected Area
1.0 - sum of windward and leeward
207 - Number of Columns
2F - F= 0.14 KN - load per column
1F - F= 0.64 KN - load per column
ALONG Z :
2F 109.13 m
2
- Projected Area
FF 327.4 m
2
- Projected Area
Total = 436.53 m
2
- Total projected Area
1.0 - sum of windward and leeward
207 - Number of Columns
2F - F= 0.60 KN - load per column
1F - F= 1.79 KN - load per column
Cpnet
# COL =
Ap =
Cpnet
Ap =
# COL =
Page 3 of 7
WIND PRESSURE ON SURFACES
INTERNAL PRESSURE COEFFICIENTS h/d
5
A. VERTICAL WALLS 1
<0.25
We = qp(ze) x cpe
h 7.3
d 30
h/d 0.243
A B C D E
-1.2 0.8 0.5 0.7 0.5
A B C D E
-1.2 -0.8 -0.5 0.8 -0.7
-1.2 -0.8 -0.5 0.8 -0.5
-1.2 -0.8 -0.5 0.7 -0.5
ZONE
h/d C
pe,10
C
pe,1
C
pe,10
C
pe,1
C
pe,10
C
pe,1
C
pe,10
C
pe,1
5 -1.200 -1.400 -0.800 -1.100 -0.500 -0.500 0.800 1.000
0
1 -1.200 -1.400 -0.800 -1.100 -0.500 -0.500 0.800 1.000
0.331 0.711 1.000
0.25 -1.200 -1.400 -0.800 -1.100 -0.500 -0.500 0.700 1.000
A B C D
C
pe,10
C
pe,1
-0.700 -0.700
-0.450 -0.450
-0.500 -0.500
-0.322 -0.322
-0.300 -0.300
E

S-ar putea să vă placă și