Integration document for

2N Helios IP intercoms

This document describes how can 2N Helios IP intercoms be integrated into 3
rd
party systems.
Describes current status, January 2014, firmware 2.6.0. Availability of interfaces depends on
intercom model, accessories and license.
SIP 2.0
standardized SIP messages according to RFC 3261

HTTP commands for lock control (part of Enhanced Integration license)
All switches in Helios IP can be controlled by HTTP commands. This feature has to be allowed in
configuration menu. HTTP command for switch control is:
http://helios_ip_address/enu/lockstate.xml.p?lockXstate=Y
X is the switch number (1-4) and Y is 0 for switch off, 1 for switch on and 2 for change over.

Optionally you can use the parameter answer for a configurable answer to this request:
http://helios_ip_address/enu/lockstate.xml.p?lockXstate=Y&answer=text, where text is the answer.

- Optionally also other functions of HIP can be controlled with HTTP commands, see manual for
Automation feature for details.

- Helios IP can control external IP devices by HTTP commands. Those commands are not given and
their form can be customized.

General HTTP commands (part of Enhanced Integration license)
Helios IP can react on predefined HTTP commands in plain URL format, such as call a number, force
end call etc. All these functions are done in Automation programming interface. See dedicated
Automation manual available on www.2n.cz or http://wiki.2n.cz
HTTP API interface
This separate interface allows a remote system to be online or offline informed about events which
occur with Helios IP, such as audio loop test result, key being pressed, card being swiped etc. It uses
HTTP XML messages. For detailed description see HTTP API manual available on www.2n.cz or
http://wiki.2n.cz
RTSP server (part of Enhanced Video license)
Video streaming from Helios IP. This feature has to be activated in configuration menu.
When enabled, one client from predefined address, or four anonymous RTSP clients can connect.
All clients get same content in the same format which is defined in Helios IP configuration.

SMTP client (part of Enhanced Integration license)
Email sending in case of unanswered call, every call (SMTP settings), or any other predefined event
(Automation settings)

Electrical outputs (number depends on installed hardware)


Force Safety Uni Vario Verso
1 (on board)
Passive and
active
Passive and
active
Passive and
active
Passive or
active
Passive and
active
2 Additional
Switch
Passive and
active
Passive and
active
- Passive Passive
3 Card Reader
module
Passive - - Passive -
4 Card Reader
module
Active - - Passive -


Passive output: 30V/1A, AC/DC (NO/NC relay output)
Active output Helios IP Force, Safety on board, Card reader or Additional switch: 9 up to 13 V
DC depending on power supply (PoE: 9 V; adaptor: power supply voltage minus 1 V), max 700 mA
Active output Helios IP Uni: 8 up to 12 V DC depending on power supply (PoE: 9 V; adaptor:
power supply voltage minus 2 V), max 500 mA
Active output Helios IP Vario: 10 up to 14 V DC depending on power supply (PoE: approx. 14 V;
adaptor: same voltage as power supply), max 700 mA
Active output Helios IP Verso: 8 up to 12 V DC depending on power supply (PoE: 10 V; adaptor:
power supply voltage minus 2 V), max 400 mA

Note: With Helios IP Force, either Additional Switch or Card reader can be used, not both at the same
time

RFID card reader 125kHz
Accepted cards:
EM4100 / EM4102 cards
26-bit and 37-bit HID Proximity cards
Working frequency: 125kHz

RFID card reader 13.56MHz
Accepted cards:
ISO14443A
Mifare Classic 1k & 4k, DESFire EV1, Mini, Plus S&X, SmartMX, Ultralight, Ultralight C, SLE44R35,
my-d move (SLE66Rxx), PayPass, Legic Advant
ISO1443B
Calypso, CEPAS, Moneo, SRI512, SRT512, SRI4K,SRIX4K, PicoPass, HID iCLASS,
Working frequency: 13.56MHz



Wiegand Helios IP Vario and Force (only with RFID card reader)
- Input / Output (as programmed). 26/32/37 bits with adjustable facility code.
Wiegand Helios IP Verso
- Both Input and Output. 26/32/37 bits with adjustable facility code.

Logical inputs Helios IP Vario and Force (only with RFID card reader)
Active mode requires external voltage
U
IN
-ON = min +2.5 V
U
IN
-OFF = max +1.5 V
U
IN
max = +48 V
I
IN
(U
IN
+48 V) = max 1 mA
Passive mode requires external contact only
U
OUT
= approx. 8.3 V
I
LOOP
= approx. 0.5 mA

Logical inputs Helios IP Verso
IN1 terminals for input in passive / active mode (-30V to +30V DC)
OFF = open OR UIN > 1.5V
ON = closed contact OR UIN < 1.5V

ONVIF (part of Enhanced Integration license)
- Protocol enabling use of Helios IP as one of industrial surveillance cameras.
- This feature has to be enabled in configuration menu and properly set.
- ONVIF version 2.2 Profile S

RS-485 not available
Maximum output voltage: 4.7 V
Minimum output voltage (into load): 1.5 V
Receiver input range: 6 V
Receiver sensitivity: 300 mV
Terminating resistance: 120 ohm (optional)