Sunteți pe pagina 1din 16

K076en 1999-04

WT500-series Digital Transmitters


Digital Transmitters
for W,T,U
Optimized for Various Sensors

Quality Data

On-line Configurable

Easy to Use & Install
K076en 1999-04
Measurements
- WS/WD 4 Hz sampling, 0.25-5 s average
- T/U 1 Hz sampling, 1 min average
I/O
- on-board RS485 (2 - and 4 wire)
- optional RS232, isolated RS485, modem
Input operating power 12.. 50 VDC, 0.1 W nominal
Temperature range
- operating / storage - 40...+ 60 C / -50..+70 C
Length / Clamp 800 mm / 60 mm (max.) (WT521)
Material
- cross arm grey anodized aluminum
- junction box grey painted aluminum
Weight 0.4, 0.7 and 1.6 kg
MTBF (Gf) 47.41 / M hours
EMC EN 50081-1, EN 50082-1
Technical Data
K076en 1999-04
Why Wind Transmitter is needed
Analog line
up to 100m
Digital line up
to 10 km
K076en 1999-04
WT501
96.6
64
46.4
-
I
N
L
1
3
C
/
A
G
N
D
-
I
N
2
3
L
2
2
2
4
2
5
O
U
T
+
I
N
C
/
A
G
N
D
E
2
0
H
2
1
1
9
2
7
2
6
2
8
A
1
A
2
M
O
D
M
O
D
A
4
A
3
A
5
M
O
D
M
O
D
M
O
D
-
I
N
O
U
T
+
I
N
L
1
8
E
1
6
H
1
7
2
9
3
1
3
0
G
N
D
F
1
5
1
4
I
N
3
2
3
4
3
3
G
L
D
I
R
G
1
D
I
R
D
I
R
G
0
G
2
G
4
G
3
D
I
R
D
I
R
D
I
R
I
N
F
1
0
+
I
N
O
U
T
H
1
2
E
1
1
3
5
3
7
3
6
I
/
O
S
G
N
D
9
S
D
+
8
3
8
3
9
G
5
O
U
T
G
N
D
D
I
R
D
+
2 C
H
E
A
T
H
E
A
T
-
I
N
I
/
O
+
I
N
D
A
T
A
6
S
D
-
7 5
D
A
T
A
4
0
4
1
4
2
H
E
A
T
R
E
T
-
R
E
T
P
W
R
4 3 2
H
E
A
T
4
3
4
4
I
N
4
5
I
N
O
U
T
F
+
F G
N
D
1 C
+
I
N
B
A
T
H
E
A
T
H
E
A
T
+
I
N
1
P
W
R
4
6
G
N
D
B
A
T
Power
Supply
On board
RS-interface
WMS-
Wind Sensor
HMP45
T/U probe
pt100-
probe
Communication
Module I/O
WAV-
Wind Vane
WAA-
Anemometer
Battery
Back up
K076en 1999-04
WT511
127.1
38
66
110
81.5
19.1
120.4
57.6
72.6
K076en 1999-04
WT521
887
145
148
K076en 1999-04
Installation
60
102
K076en 1999-04
Jumpers
Modem line supply:
X4/1-2
X5/1-2
X16 open
Heating options:
Series (40 VDC)
X6/2-3
Parallel (20 VDC)
X6/1-2 & X6/3-4
K076en 1999-04
WAA/WAV151 sensor heating options
WT 501 WT 501
Series Parallel
+40V +20V
Jumpers X6/2-3 Jumpers X6/1-2&3-4
K076en 1999-04
WT501 Powering options
Local powering Powering via modem line
WHP151
20VDC
MODEM
LINE
115/230VDC
24VDC
Jumpers:
X4/1-2
X5/1-2
X16 open
MODEM
LINE +
48VDC
SUPPLY
VOLTAGE
24VDC
WIND50 WIND50
WT501 WT501
Jumpers:
X16/1-2
X4 open
X5 open
K076en 1999-04
Automatic message mode
Main system
Output messages sent
automatically by the
transmitter at specified
intervals
Only one transmitter in the communication line
K076en 1999-04
Polling Mode
ID A
1. The main system sends a
polling command with an ID
Main system
Polling is necessary if several transmitters
share the same communication line
All transmitters need to have unique IDs
ID B
ID C
2. Only a
transmitter with
correct ID
responds with a
data message
K076en 1999-04
Configuration
OR
T
x
D
R
x
D
G
N
D
K076en 1999-04
Set up the terminal program
... use 100 ms time delay between each line
Type RESET <Enter>
... if not included in the file
... or reset the transmitter
Send the *.CFG file to the transmitter
(could be named *.txt file as well)
Type OPEN <Enter>
Set up the terminal program
Type RESET <Enter>
... or reset the transmitter
Type commands to the transmitter
Type OPEN <Enter>
Two Methods of Configuration
On-line Configuration File Transfer Configuration
K076en 1999-04
Command Set
Command Parameter Range Description
SETSPD AVERAGE 0.25 .. 5.00 Wind speed [s] integration time
SETDIR AVERAGE
OFFSET
0.25 .. 5.00
-180 .. 180
Wind direction [] integration time
Wind direction static correction []
SETCOM 0
or
SETCOM 1
BAUDRATE
DATABITS
STOPBITS
PARITY
WIRES
CCITT
MULTIDROP
ORIGINATE
300, .., 9600
7, 8
1, 2
NONE, EVEN, ODD
2, 4
V.21, V.22, V.23
0, 1
0, 1
Data transfer rate
Number of databits (per frame)
Number of stopbits (per frame)
Parity
Half duplex (2) or full duplex (4)
Refers to modem speed
Multibus access
Modem originate/answer
SETDEV ID String of five octets Device identification
SETMEA WA151
SETMEA WMS301
SETMEA WMS302
SETMEA HMP45
SETMEA PT100
ACTIVE
SPEED
0 / 1
LOW, NORMAL, HIGH
Measurement active/inactive
WA151 powering & sampling
SETMES 1
or
SETMES 2
or
SETMES 3
or
SETMES 4
TYPE
COM
INTERVAL
TRIG
COMOUT
STRING
CHECK
POLY
INIT
REFIN
REFOUT
XOROUT
NONE, OUT, IN,
XDR_TU, MWV,
MWVQUERY,
MWVPOLL, WAT11
WAT11QUERY,
WAT11POLL,
DD50_TU, THRU
0, 1
0.0 .. 600.0
0 .. 4
0.. 1
string upto 80 chars
NONE, XOR, SUM,
CRC16
0000 .. ffff
0000 .. ffff
0, 1
0, 1
0000 .. ffff
Pre defined messages
Communication port number
Sending interval [s]
Message to be send; 0 = none
Output port for THRU-message
Message string format definition
Checksum type
CRC polynomial (hex)
Checksum register initial value
Reflection of incoming bits
Reflection of outgoing bits
XOR value for outgoing chksum
SETHEA ACTIVE
POLARITY
TOS
THYS
0, 1
0, 1
-55 .. 125
-55 .. 125
Heating OFF or ON
Heat control polarity (1 as default)
Heating OFF (polarity = 1)
switching point (10 C as default)
Heating ON (polarity = 1) switching
point (5 C as default)
K076en 1999-04
Block Diagram
O
p
t
i
o
n
a
l

C
o
m
m
u
n
i
c
a
t
i
o
n
D
i
r
e
c
t
i
o
n

s
e
n
s
o
r
S
p
e
e
d

s
e
n
s
o
r
6

V
B
a
t
t
e
r
y
+
Heat
Heat
S
e
r
i
a
l

I
/
O
W
M
S
3
0
1
/
3
0
2
H
M
P
3
5
/
4
5
P
t
-
1
0
0
Isolated
power supply
section
OVP/EMC
Protection
OVP
+
RS-485
drive
500kHz isolated
power supply for
RS-485 port
Optional Communication
Module
Bus buffer +
level shift
OVP+
Sensor
excitation
unit
GRAY
input
Speed
input
OVP
+B
uffers
OVP
MUX
+
OVP
MUX
+
Hitachi
H8 3048F
CPU
Reset
127 kB
internal
Flash
Boot
loader
128 kB-
512 kB
SRAM
External
WD-
timer
16-bit
ADC
+
Programmable
front-end
Heat control
3V3
OK on/off
8 MHz
ISO +5V
ISO GND
RS-Port 1
Power Good/Fail -> NMI
+7/12 V to sensors
+ 5 V to ADC
+ 5 V to Comms module
3V3 to CPU
2.5 V ref.
-3V to ADC
Ext. DC level
Heat AC 20 -> 40 V DC/AC 0 -> 2 A
Raw 10 V
F1
+
Power
ON
Pulse/
f out
Heat
Heat
Power
OK
3V3 5V
+ 3 / 5 V
INT
8bit CPU bus
Serial SPI
100.00
100.00
0-12 V
2.50 V / 12 V
Pulse input
0-12 V Fast DAC
0-12 V Fast DAC
0 -> 12 V Fast 10bit ADC
0 -> 12 V Fast 10bit ADC
12 V / 2.5 V excitation out
Pulse input
3V3 3V3
SCL
SDA SDA
Heat ON
status
3V3 3V3
+7 / 12 V
+7 / 12 V
Green
Red
Reset
OVP+
Sensor
excitation
unit
Two dual
opto coupler
isolation
TxEN Enable
3V3
+ 5 V
- 3 V
2.5 V ref.
RS-Port 2
Isolation
9809-006