valve TAG Remarks Done Yes/no LV3002 by pass 6"PW400028 1 Yes FE3000 by pass 8"GH300018 2 Yes Drain header to closed drain 4"DF350001 3 Yes Oil outlet to closed drain 1"DF350288 4 Yes water outlet to 8'' oily water header 6'' PW400028 require flexible Yes LDG 3000 Yes LDT 3001 Yes LDT 3002 Yes LG 3003 Yes LT 3004 Yes LT 3005 Yes Link water/oil outlet 6"GH300038 5 Yes Sampling oil outlet 18"GH300040 6 Yes Drain header to closed drain 4"DF350002 7 Yes water outlet to 8'' oily water header 6'' PW400001 require flexible No LDG 3010 Yes LDT 3011 Yes LDT 3012 Yes LG1 3013 Yes LG2 3013 Yes LDT 3014 Yes LDT 3015 Yes 10'' GH300127 No 10'' GH300128 No 12'' GH300129 No 12'' GH300130 No DS301 outlet to closed drain C523A-P 8 Yes Outlet EC313A to closed drain 2"DF350211 9 No 1" EC313A body drain cold side 1" 10 No Outlet EC313B to closed drain 2"DF350213 11 Yes 1" EC313B body drain cold side 1" 12 Yes Outlet EC313C to closed drain 2"DF350215 13 Yes 1" EC313C body drain cold side 1" 14 Yes Outlet EC313D to closed drain 2"DF350217 15 Yes 1" EC313D body drain cold side 1" 16 Yes EC313 A/B/C/D by bass cold side 16"GH300096 17 Yes Link water/oil outlet 3"GH300071 18 Yes Drain header to closed drain 4"GH300075 19 Pressure balanced by LG drain Yes water sampling connection 4 ''PW 300073 Yes LDG2 3020 Yes LDT 3021 Yes LDT 3022 Yes LG1 3023 Yes LG2 3023 Yes LG3 3023 Yes LT 3024 No flushing line No LT 3025 No flushing line No GX310A suction strainer drain 2"DF350080 20 to be done even if pump not running Yes GX310A discharge drain 2"DF350077 21 to be done even if pump not running Yes GX310A suction vent 1"GH310074 22 to be done even if pump not running Yes GX310B suction strainer drain 2"DF350080 23 to be done even if pump not running No GX310B discharge drain 2" 24 to be done even if pump not running No GX310B suction vent 1"GH310075 25 to be done even if pump not running No PDV3201A by pass 2" by pass 26 Yes 1"Drain of DS320A inlet 1"DF350292 27 Yes 3" drain of outlet water 4"PW320028 28 Yes GX320 discharge to oily water package 4"PW400006 29 Yes try-cock Yes LDG3204A Yes LDT3202A Yes LDT 3201A Yes PDV3201B by pass 2" by pass 30 Yes 3" drain of outlet water 4"PW320016 31 Yes EC321 by pass 4"PW320028 32 Yes Oily water U/S EC321 to open Drain 2"DO360079 33 Yes Oily water to sand jet DS400 3"PW400058 34 Yes Oily water to sample box 2"PW400042 35 Yes 1"Drain of DS320B inlet 3/4" 36 Yes try-cock Yes LDG3204B Yes LDT3202B Yes LDT 3201B Yes DS401( Vendor PID) Drain D/S LV4007 3/4" 37 Yes GX400A discharge drain to closed drain 1"DF350244 38 Yes GX400B discharge drain to closed drain 1"DF350245 39 Yes GX400B PSV 4012B 1 1/2'' PW400054 Yes GX400A PSV 4012A 2 1/2'' PW400056 Yes CA310 water condensate pot 2'' PW400004 require flexible Impossible GX350A recirculation line 2"DF350222 40 Yes GX350B recirculation line 2"DF350223 41 Yes DEAD LEG WHILE DS 320B BY PASS GX320: pump stopped DS320B/1955(02) Mini flow GX320 2"PW320025 In Service Yes GX320 unavailable for long time GX320A suction line 6"PW320016 Drain by 3/4"drain valve Yes GX320A discharge line 4"PW320018 Drain by 3/4"drain valve Yes GX320B suction line 6"PW320017 Drain by 3/4"drain valve No GX320B discharge line 4"PW320019 Drain by 3/4"drain valve No Instruction: Flush 2 hours after the beginning of biocide treatment Location Pump Yes / No DS300 GX822B Yes DS301 GX822B Yes DS302 GX822B No PSV3130A (or B) CANCELLED No DA350 GX822B Yes Suction GX722/721A/B GX822B Yes \\vboxsrv\conversion_tmp\scratch_5\[246834379.xls.ms_office.xls]Dead legs Injection point of Biocide Treatment PSV3130: no more biocide required due to bonnet destruction of PSV. Not in Service PSV3130A/B DS300/ 1950 DS301/1951 EC313/1953 (01/02) Skimmed oil pipe DA350/1866 DS320A/1955(02) DS302/1953 (02/02) GX310/1954 DS320A/1955(01/02) DS320B/1955(02/02)