ATTENTION:

Before installing, configuring, operating, or maintaining this product, read this document and the documents listed in the Additional Resources section for installing, configuring, or operating equipment. Users should familiarize
themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards.
Installation, adjustments, putting into service, use, assembly, disassembly, and maintenance shall be carried out by suitably trained personnel in accordance with applicable code of practice.
If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls, publication SGI-1.1, available from
your local Rockwell Automation sales office or online at http:/www.rockwellautomation.com/literature/ describes some important differences between solid state equipment and hard-wired electromechanical devices.
ATTENTION: Do not install, configure, operate, or maintain this product until you have read the product documentation and the documents in the Additional Resources section for installing, configuring, operating or maintaining equipment.
To get the product documentation go to http://www.rockwellautomation.com/literature/ or contact your local sales office or Rockwell Automation representative.
ATTENTION: Ne pas installer, configurer, exploiter ou maintenir ce produit tant que vous navez pas lu sa documentation et les documents de la rubrique Documents connexes pour linstallation, la configuration, lexploitation et la
maintenance de lquipement. Pour obtenir de la documentation, rendez-vous sur le site http://www.rockwellautomation.com/literature/ ou contactez votre agence commerciale Rockwell Automation locale ou son reprsentant.
ACHTUNG: Fr die Installation, Konfiguration, den Betrieb und die Wartung dieses Produkt lesen Sie sich bitte zunchst die Produktdokumentation sowie die Dokumente im Abschnitt Weitere Informationen durch. Die entsprechende
Produktdokumentation finden Sie unter http://www.rockwellautomation.com/literature/ oder kontaktieren Sie Ihr lokales Vertriebsbro bzw. einen Rockwell Automation-Mitarbeiter.
ATENCIN: No instale, configure, opere ni mantenga este producto hasta que haya ledo la documentacin del producto y los documentos en la seccin Recursos adicionales para la instalacin, configuracin, operacin o mantenimiento de
equipo. Para conseguir la documentacin, dirjase a http://www.rockwellautomation.com/literature/ o pngase en contacto con su oficina regional de ventas o representante de Rockwell Automation.
ATENO: No instale, configure, opere ou mantenha este produto at que voc leia a documentao do produto e os documentos na seo Recursos adicionais para a instalao, configurao, operao ou manuteno do equipamento. Para
conseguir a documentao, visite http://www.rockwellautomation.com/literature/ ou entre em contato con seu escritrio de vendas regional ou representante da Rockwell Automation.
ATTENZIONE: Non installare, configurare, attivare o riparare questo prodotto senza avere prima letto la relativa documentazione nonch i documenti indicati nella sezione Ulteriori Risore riguardanti linstallazione, la configurazione,
lattivazione o la riparazione dellapparecchiatura. Per la documentazione sul prodotto visitare il sito http://www.rockwellautomation.com/literature/ o contattare lufficio vendite o il rappresentate Rockwell Automation di zona.
:
Web http://www.rockwellautomation.com/literature/

: , , , .
http://www.rockwellautomation.com/literature/ .
:
http://www.rockwellautomation.com/literature/

http://www.rockwellautomation.com/literature/
: , ,
, , . ,
http://www.rockwellautomation.com/literature/ Rockwell Automation.
UWAGA: Nie instaluj i nie uruchamiaj tego urzdzenia dopki nie zapoznasz si z instrukcj uytkownika produktu. Aby uzyska dokumentacj produktu przejd do strony internetowej http://www.rockwellautomation.com/literature/ lub
skontaktuj si z lokalnym biurem sprzeday lub przedstawicielstwem firmy Rockwell Automation.
UPOZOREN: Neprovdjte instalaci, konfiguraci, provoz ani drbu, pokud jste dosud nepeetli dokumentaci k produktu a dokumenty obsaen v sekci Doplujc informace pro instalaci, konfiguraci, provoz a drbu. Tuto dokumentaci
mete zskat na http://www.rockwellautomation.com/literature/ nebo od obchodnho zstupce spolenosti Rockwell Automation.
WAARSCHUWING: Installeer, configureer of onderhoud dit product niet vooraleer u de productdocumentatie en de documenten in de aanvullende informatiesectie voor installatie, werking en onderhoud gelezen hebt. Voor de
productinformatie, ga naar http://www.rockwellautomation.com/literature/ of contacteer uw lokaal Rockwell Automation-kantoor.
Product Information
1407-CGCM Combination Generator Control Module
Original Instructions
The Combination Generator Control Module (CGCM unit) is a microprocessor-based control and protection device. The CGCM unit is designed to integrate with a Logix family programmable controller to provide generator control, protection and
synchronization functions. Programmability of system parameters, regulation settings, and protective functions enable the CGCM unit to be used in a wide range of applications.
Important User Information
This document uses these symbols to make you aware of safety considerations.
IMPORTANT This document contains important information related to agency certifications for the Combination Generator Control Module. The product is marked with all agency approvals and certifications.
This document is not intended for installing, configuring, or operating this product. Do not install this product until you have first read this document and the appropriate documents under Additional Resources. For declarations of
conformity, certificates, and other certification details, visit the Product Certifications page at http://www.ab.com.
IMPORTANT Any illustrations, charts, sample programs, and layout examples shown in this publication are intended solely for the purposes of example. Since there are many variables and requirements associated with any particular installation,
Rockwell Automation does not assume responsibility or liability for actual use based upon the examples shown in this publication.
ATTENTION: In case of malfunction or damage, no attempts at repair should be made. The module should be returned to the manufacturer for repair. Do not dismantle the module.
WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss.
ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence.
2 1407-CGCM Combination Generator Control Module
Rockwell Automation Publication 1407-PC001A-EN-P - April 2013
Certifications
The Combination Generator Control Module has these certifications.
North American Hazardous Location Approval
Environment and Enclosure Information
Temperature Specifications
Wiring Specifications
Protective Earth/Chassis Ground Wiring
The terminal labeled CH GND, located on TB4, is the chassis ground. Ground studs are additionally provided on the lower part of the mounting flanges and are internally connected to the CH GND terminal. Chassis ground should be connected to
earth ground with minimum 2.6 mm
2
(10 AWG) copper wire attached to either stud located on the lower part of either side of the unit and with 1.6 mm
2
(14 AWG) to the CH GND terminal.
Region
(1)

(2)

(3)
(1) This equipment is intended to be mounted inside a suitable ATEX certified enclosure providing a minimum of IP54 protection.
(2) This equipment is intended for use in a Pollution Degree 2 industrial environment or better.
(3) The device is to be powered by a 24V Nominal Battery or 24V DC Power Supply with ATEX certification.
Certification / Compliance Standard
USA and Canada Class I, Zone 2,
AEx nC IIC T3, Ex nL IIC T3 Gc X
UL 60079-15 3rd Edition / CSA 60079-15:12
UL 60079-0 5th Edition / CSA 60079-0:11
Class I, Division 2, Groups A, B, C, or D
UL File E220640
ANSI/ISA 12.12.01-2012 / CSA C22.2 No. 213-M1987
Europe
II 3G Ex nL IIC Gc (DEMKO 13 ATEX 1202591U)
EN 60079-0:2009
EN 60079-15:2005
The following information applies when operating this equipment in hazardous locations. Informations sur lutilisation de cet quipement en environnements dangereux.
Products marked "CL I, DIV 2, GP A, B, C, D" are suitable for use in Class I Division 2 Groups A, B, C, D, Hazardous Locations
and nonhazardous locations only. Each product is supplied with markings on the rating nameplate indicating the
hazardous location temperature code. When combining products within a system, the most adverse temperature code
(lowest "T" number) may be used to help determine the overall temperature code of the system. Combinations of
equipment in your system are subject to investigation by the local Authority Having Jurisdiction at the time of
installation.
Les produits marqus "CL I, DIV 2, GP A, B, C, D" ne conviennent qu' une utilisation en environnements de Classe I Division
2 Groupes A, B, C, D dangereux et non dangereux. Chaque produit est livr avec des marquages sur sa plaque
d'identification qui indiquent le code de temprature pour les environnements dangereux. Lorsque plusieurs produits
sont combins dans un systme, le code de temprature le plus dfavorable (code de temprature le plus faible) peut tre
utilis pour dterminer le code de temprature global du systme. Les combinaisons d'quipements dans le systme sont
sujettes inspection par les autorits locales qualifies au moment de l'installation.
WARNING:
Explosion Hazard -
Do not disconnect equipment unless power has been removed or the area is known to be
nonhazardous.
Do not disconnect connections to this equipment unless power has been removed or the area is known
to be nonhazardous. Secure any external connections that mate to this equipment by using screws,
sliding latches, threaded connectors, or other means provided with this product.
Substitution of components may impair suitability for Class I, Division 2.
If this product contains batteries, they must only be changed in an area known to be nonhazardous.
AVERTISSEMENT:
Risque dExplosion
Couper le courant ou s'assurer que l'environnement est class non dangereux avant de dbrancher
l'quipement.
Couper le courant ou s'assurer que l'environnement est class non dangereux avant de dbrancher les
connecteurs. Fixer tous les connecteurs externes relis cet quipement l'aide de vis, loquets
coulissants, connecteurs filets ou autres moyens fournis avec ce produit.
La substitution de composants peut rendre cet quipement inadapt une utilisation en environnement
de Classe I, Division 2.
S'assurer que l'environnement est class non dangereux avant de changer les piles.
ATTENTION: This equipment is intended for use in a Pollution Degree 2 Industrial Environment, in over-voltage Category II applications (as defined by IEC publication 60664-1). Because the units contain a heat sink, they must be
mounted vertically. Any other mounting angle reduces the heat dissipation capabilities of the units, possibly leading to premature failure of critical components. The unit may be mounted anywhere that the ambient temperature
does not exceed the rated environmental conditions or clearance requirements. These are the clearance requirements for the CGCM unit:
63.5 mm (2.5 in.) of clearance is required on both sides of the unit when mounted
101.6 mm (4 in.) of clearance is required above and below the unit when mounted
This device is supplied as open-type equipment and is intended to be mounted inside a suitable enclosure providing a minimum of IP54 protection.
In addition to this publication, refer to these other publications:
Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1, for additional installation requirements.
NEMA Standards 250 and IEC 60529, as applicable, for explanations of the degrees of protection provided by different types of enclosure.
Attribute 1407-CGCM
Temperature, operating -2070 C (-4158 F)
Temperature, storage -4085 C (-40185 F)
Table 1 Power Wiring
Circuit
Input Voltage
(1)
(1) See label on product for power or current requirements.
Wire Type
Wire Size
(3)
(3) Single wire size.
Terminal Screw Torque
Control Power - 1832V DC
(The device is to be powered by a 24V Nominal Battery
or 24V DC Power Supply with ATEX certification.)
Cu 105 C (221 F)
(2)
stranded or solid
(2) Minimumrequired insulation temperature rating. For ambient temperatures below-10 C and above 60 C use field wiring suitable for both the minimumand maximumambient temperature.
1.61.0 mm
2
(1418 AWG) N/A
(4)
(4) Spring clip terminals.
Generator Reference 57208V AC -
Bus Reference 57208V AC -
PMG Power 79300 VAC -
2.62.1 mm
2
(1012 AWG)
1 Nm (9 lbin)
Current Sense 05 A AC -
1407-CGCM Combination Generator Control Module 3
Rockwell Automation Publication 1407-PC001A-EN-P - April 2013
Class I, Zone 2 Installations
This section provides information for Class I, Zone 2 installations.
Cable Length Determination
Capacitance and inductance of the field wiring from the intrinsically safe equipment (the 1407-CGCM unit) to the associated apparatus (for example, current transformer or load share compatible devices) shall be calculated and must be included
in the system calculations shown in Table 2. Cable capacitance, Ccable, plus intrinsically safe equipment capacitance, Ci, must be less than the marked capacitance, Ca (or Co), shown on any associated apparatus used. The same applies for
inductance (Lcable, Li and La or Lo, respectively). Where the cable capacitance and inductance per foot are not known, the following values shall be used: Ccable = 60pF/ft., Lcable = 0.2 uH/ft.
Field Wiring Terminals and Entity Parameters
Figure 1 - Class I, Division 2 Groups A, B, C, & D, Class I Zone 2 IIC Area
Installation
Associated apparatus must be installed in accordance with its manufacturer's control drawing and Article 504 of the National Electrical Code (ANSI/NFPA 70) for installation in the United States, or Section 18 of the Canadian Electrical Code for
installations in Canada and EN 60079-14 for European installations or in accordance with the local installation codes.
Table 2 Required Circuit Parameters for the Associated Apparatus
Nonincendive/Energy Limited (Intrinsically Safe) Equipment Associated Apparatus
Vmax (or Ui) Voc or Vt (or Uo)
Imax (or Ii) Isc or It (or Io)
Pmax (or Pi)
Po
(1)
(1) If Po of the associated apparatus is not known, it may be calculated by using the formula Po = (Voc * Isc) / 4 = (Uo * Io) / 4.
Ci + Ccable Ca (or Co)
Li + Lcable La (or Lo)
Table 3 Symbol Definitions
Symbol Definition
Vmax or Ui Maximum voltage that may be connected to the specified terminals of the I.S. device (1407-CGCM unit)
Imax or Ii Maximum current that may be connected to the specified terminals of the I.S. device (1407-CGCM unit)
Pmax or Pi Maximum power that may be connected to the specified terminals
Voc, Vt or Uo Maximum open-circuit voltage that may be present at the output terminals of the associated equipment
Isc, It or Io Maximum short-circuit current that may be present at the output terminals of the associated equipment
Po Maximum output power from the output terminals of the associated equipment
Ci Apparent capacitance at the specified terminals of the I.S. device
Ca or Co Maximum capacitance that may be connected to the output terminals of the associated equipment
Li Apparent inductance at the specified terminals of the I.S. device
La or Lo Maximum inductance that may be connected to the output terminals of the associated equipment
Ccable Cable capacitance
Lcable Cable inductance
ID (+) 1 A
ID (+) 5 A
ID (-)
Cross Current Compensation
Ui = 12V DC
Ii = 5 A
Pi = 60 W
Ci = 14.1 nF
Li = 1.5 uH
TB3
Load Sharing
LS(+)
LS(-)
TB7
Ui = 5V DC
Ii = 5 A
Pi = 25 W
Ci = 101 nF
Li = 0 H
Publication 1407-PC001A-EN-P - April 2013 PN-174206
Supersedes Publication Supersede Pub Number - Supercede Pub Date Copyright 2013 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
Allen-Bradley, Rockwell Software, Rockwell Automation, RSLogix 5000, and ControlLogix are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Otomasyon Ticaret A.., Kar Plaza Merkezi E Blok Kat:6 34752 erenky, stanbul, Tel: +90 (216) 5698400
Additional Resources
These documents contain additional information concerning related products from Rockwell Automation.
You can view or download publications at http://www.rockwellautomation.com/literature/. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.
Resource Description
Combination Generator Control Module User Manual, publication 1407-UM001. Provides information on using the Combination Generator Control Module.
Combination Generator Control Module Release Notes, publication 1407-RN001 Provides information on compatible RSLogix 5000 software revisions and ControlLogix controller firmware revisions.
Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls, publication SGI-1.1 Describes some important differences between solid-state equipment and hard-wired electromechanical devices.
ControlNet Coax Media Planning and Installation, publication CNET-IN002 Provides installation procedures for the ControlNet network.
Logix5000 Controllers Common Procedures, publication 1756-PM001 Provides information about RSLogix 5000 software.
Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Provides general guidelines for installing a Rockwell Automation industrial system.
Product Certifications website, http://www.rockwellautomation.com/products/certification Provides declarations of conformity, certificates, and other certification details.