Fuel Type Cost/Unit Units /kBtu (site)

Electric 12 /kWh 3.52 FloorArea 2000 ft


2
Read Me
NaturalGas $1.60 $/therm 1.55 HeatLoss kBtu/h
Propane $2.50 $/gal 2.74 HeatSqFt 32 kBtu/h-ft
2

HeatingOil $3.00 $/gal 2.14 HeatReqd 64.0 kBtu/h


Wood $200.00 $/cord 1.00 HeatHours 900 Hours/year
Gasoline $3.00 $/gal = 2.46
kW kWh Fuel Units Electric Fuel Total
Electric Furnace COP 1 18.76 16,882 $2,025.79 $2,025.79
Air Heat Pump HSPF 5.5 Btu/W-hr 11.64 10,473 $1,256.73 $1,256.73
Ground Heat Pump COP 3.7 Watt/Watt 5.07 4,563 $547.51 $547.51
Natural Gas AFUEng 80 % 1 in. of water 0.30 268 576 $32.13 $1,152.00 $1,184.13
Propane AFUEpro 80 % 1 in. of water 0.30 268 632 $32.13 $1,973.68 $2,005.82
Oil AFUEoil 80 % 1 in. of water 0.30 268 411 $32.13 $1,542.86 $1,574.99
Wood Stove Efficiency 60 % 0.5 in. of water 0.15 134 2.9 $16.07 $960.00 $976.07
Region Low High Region Poor Quality Std. Quality Hi. Quality Super Eff.
House 600 800 House 30 20 15 10
School 200 400 School 30 22 15 10
Office 200 700 Office 22 18 14 11
House 800 1000 House 40 32 25 16
School 300 500 School 35 27 20 13
Office 700 900 Office 25 22 15 12
House 1000 1500 House 50 40 30 20
School 500 600 School 40 30 25 15
Office 900 1100 Office 30 24 18 13
Standby Loss Distrib. Loss AFUE/COP kWh/Fuel Use Annual Cost
ColdWtrTin 60 F Electric 10% 10% 1 3882 $504.61
HotWtrTout 120 F Nat Gas 10% 10% 65% 204 $326.01
GalperDay 60 Gal/day Propane 10% 10% 65% 223 $558.54
kBtuperDay 30.0 kBtu/Day Heating Oil 10% 10% 65% 146 $436.62
HeatPump WH 10% 10% 2 1941 $252.31 CoolMonths HeatMonths HeatPumpType
10% 10% 3.27 1187 $154.32 6 6 Air Source
HtUnitCOP 1.61
Cooling Electric Rate Cost/Unit Units HeatGain kBtu/h
ElectricSum 14 /kWh CoolSqFt 22 kBtu/h-ft
2

CoolReqd 44.0 kBtu/h


CoolHours 900 Hours/year
kW kWh Energy Cost
Air Source AC or HP
1
AvgEERAS 11 Btu/W-hr 4.00 3,600 $504.00 Head (ft.) gpm/ton kW
Ground Source HP
2
AvgEERGS 14 Btu/W-hr 3.14 2,829 $396.00 0 2.4 0.00
Chillers
3
kWperTon 0.7 kW/ton 3 in. of water 4.17 3,755 $525.67 50 2.4 0.15
Region Low High Region Poor Quality Std. Quality Hi. Quality Super Eff.
House 1100 1600 House 32 25 17 10
School 600 1000 School 65 53 36 31
Office 1200 1800 Office 35 28 20 15
House 800 1000 House 30 22 15 9
School 400 550 School 60 48 38 28
Office 700 1100 Office 30 25 17 14
House 200 300 House 28 20 14 8
School 200 300 School 50 42 30 26
Office 300 600 Office 28 22 16 12
Annual Total
ElectCO
2
kWh
1.35
Heating ,Cooling & GroundHeatPump Elect&HtRec GroundHeatPump Heat Water Heat Cool
Water Heating Cost Heating WaterHeat Cooling GroundHeatPump Elect&HtRec GroundHeatPump
$1,098 $548 $154 $396 6,160 1,603 3,819
Chilled Water
Annual Cooling Cost Optional Pumps for Chilled Water and/or Water-Cooled Systems
Included in EER
Included in EER
Supply Fan TSP
Annual Heating Cost
HeatHours Estimates
FYI - Unit Energy Cost Comparison to Gasoline
Fan TSP
Included in COP
Included in HSPF
Included in COP
South
Mid-USA
South
HeatSqFt Estimates (kBtu/h per 1000 ft
2
of Floor Area)
Mid-USA
North
South
Mid-USA
North
Pounds Carbon Dioxide Produced
ElectricWithHeatRecovery A.K.A Desuperheater
North
CoolSqFt Estimates (kBtu/h per 1000 ft
2
of Floor Area)
South
Mid-USA
North
CoolHours Estimates
& Water Heating CO
2
11,581
Additional Info Needed for Heat Recovery
Heating, Water Heating and Cooling Energy, Cost and Carbon Dioxide Estimator
Heating Cost Estimator
Water Heating Cost Estimator
Cooling Cost Estimator
Select Heating, Wtr Heat, Cooling Types
Annual Heating ,Cooling
1. The value of Average EER for Air-Source Air-Conditioners and Heat Pumps is used rather than the Seasonal Energy Efficiency Ratio. SEER is based on an indoor
temperature of 80F, an outdoor temperature or 82F, insufficient fan power requirement, and insufficient moisture removal capability in most climates. These
conditions substantially over-predict cooling efficiency. (See "Climatic Impacts on HSPF and SEER for Air-Source Heat Pumps", Fairey, et. al., ASHRAE Transactions,
Vol. 110, Part 2, 2004.)
2. The value of Average EER for Ground Source Heat Pumps is used rather than the Ground Loop Heat Pump (GLHP) Energy Efficiency Ratio. GLHP-EER is based
on an indoor temperature of 80.6F, a ground loop temperature of 77F, and insufficient fan power requirement. These conditions over-predict cooling efficiency
especially in southern climates or when ground loops are poorly installed or under-sized.
3. The capacity and electrical demand of chillers does not include the power use of auxillary equipment and the corresponding heat deduction for distribution of the
chilled water and air. This computation includes the power input of the supply fans, chilled water pumps and condenser pumps. It also includes a correction to account
for the heat introduced into the system by the supply air handler and chilled water pump. It does not include any penalties if return air fans or fan powered VAV
terminals. This can be estimated by adding the total static pressure (TSP) to the supply fan TSP.
Head (ft) t(sup)-t(ret)gpm kW
0 40 4.6 0.0
0 40 4.6 0.0
0 40 4.6 0.0
0 40 4.6 0.0
0 40 4.6 0.0
HeatPumpType
Head (ft.) gpm/ton kW
50 3 0.19
Not Applicable
Not Applicable
Condenser Water
Optional Pumps for Chilled Water and/or Water-Cooled Systems
Included in EER
Optional Hot Water Pumps
Electrical Generation Emissions - Pounds (CO2/kWh)
New England 1.07 Mid Atlantic 1.07
South Atlantic 1.34 E. South Central 1.47
E. North Central 1.63 W. North Central 1.75
W. South Central 1.5 Mountain 1.56
Pacific Contiguous 0.43 Pacific Noncontig. 1.42
http://www.eia.doe.gov/electricity/page/co2_report/co2report.html