36

Merlin Gerin
circuit breaker NS400 1000 V
Compact circuit breaker NS400 1000 V
number of poles 3
CT (A) (current transformer) 150 250 400
electrical characteristics
rated operational voltage (V) Ue AC 50/60 Hz 1150 1150 1150
ultimate breaking capacity (kA rms) Icu AC - 1000 V 10 10 10
service breaking capacity Ics (% Icu) 100% 100% 100%
electrical characteristics as per IEC 947-2 and EN 60947-2
rated current (A) In 40C 150 250 400
rated insulation voltage (V) Ui 1250 1250 1250
rated impulse withstand voltage (kV) Uimp 8 8 8
rated operational voltage (V) Ue AC 50/60 Hz 1000 1000 1000
ultimate breaking capacity (kA rms) Icu AC - 1000 V 10 10 10
service breaking capacity Ics (% Icu) 100% 100% 100%
suitable for isolation c c c
utilisation category A A A
pollution degree III III III
protection
protection against overcurrents electronic trip unit
STR23SP c c c
instantaneous 9 In 9 In 9 In
earth fault protection
installation and connections
fixed/front connection c c c
fixed/rear connection consult us
plug-in (on base) consult us
withdrawable (on chassis) consult us
indication and measurement auxiliaries
auxiliary switches c c c
voltage presence indicator
current transformer module
ammeter module
insulation monitoring module
control auxiliaries
auxiliary releases c c c
motor mechanism c c c
rotary handles (direct extended) c c c
manual/automatic source changeover systems consult us
installation and connection accessories
bare cable connectors consult us
terminal extensions and spreaders consult us
terminal shields standard
escutcheon c c c
dimensions and weights
dimensions L x H x D (mm) (1) 3 poles, fixed, FC 140 x 480 x 110
weight (kg) 3 poles, fixed, FC 13
0
5
3
1
8
2
NS400 1000 V
Compact: functions and characteristics
protection of low-voltage distribution networks
1000 V circuit breakers
(1) with terminal shields.
Merlin Gerin
37
circuit breaker C1251N 1000 V
(1): For withdrawable version do not use a
current setting higher than:
- 1160 A at 40C,
- 1080 A at 50C,
- 1000 A at 60C.
(2): Defined for a power factor cos = 0.3.
Compact circuit breaker C1251N 1000 V
number of poles 3
CT (A) (current transformer) 400 800 1250
electrical characteristics as per IEC 947-2 and EN 60947-2
rated current (A) In 40C 400 800 1250 (1)
50C 400 800 1150 (1)
60C 400 800 1050 (1)
rated insulation voltage (V) Ui 1000 1000 1000
rated impulse withstand voltage (kV) Uimp 8 8 8
rated operational voltage (V) Ue AC 50/60 Hz 1000 1000 1000
ultimate breaking capacity (kA rms) (2) Icu AC - 1000 V 20 20 20
service breaking capacity Ics (% Icu) 50% 50% 50%
short-time withstand current Icw kA rms 15 15 15
t (s) 1 1 1
suitable for isolation c c c
utilisation category B B B
pollution degree III III III
protection
protection against overcurrents interchangeable
electronic trip unit c c c
STR25DE c c c
STR35GE/SE/ME (3) c c c
STR55UE (3) c c c
earth fault protection c c c
installation and connections
fixed/front connection c c c
fixed/rear connection c c c
plug-in (on base)
withdrawable (on chassis) c c c
indication and measurement auxiliaries
auxiliary switches c c c
electronic trip unit related functions c c c
voltage presence indicator
current transformer module
ammeter module
insulation monitoring module
control auxiliaries
auxiliary releases c c c
motor mechanism c c c
rotary handles (direct extended) c c c
manual/automatic source changeover systems c c c
installation and connection accessories
bare cable connectors c c c
terminal extensions and spreaders c c c
terminal shields and phase barriers c c c
escutcheon c c c
dimensions and weights
dimensions L x H x D (mm) 3 poles, fixed, FC 210 x 374 x 172
weight (kg) 3 poles, fixed, FC 13
(3)
instantaneous CT400/800 CT1250
fixed: STR35 15 x In 12 x In
adjustable: STR55
2 to: 15 x In 12 x In
0
5
1
3
5
3
C1251N 1000 V