Documente Academic
Documente Profesional
Documente Cultură
INFORMATION SYSTEM
Lightning Data Logger
Live Application
With many years experience in design and considering the various on-site severe
environmental impacts, the T03-A2 Lightning data recorder has been developed
through 2 years of continuous improvements, which is dedicated to petrochemical,
railway and communication fields. Without maintenance management and external
power supply, it is easy to install and record data via wireless network transmission.
In the lightning protection and monitoring fields, the T03-A2 Lightning Peak Value
Recorder is a digital lightning current monitoring and recording device with practical
value. It may be used to record direct lightning current flowing through the arresting
device(lightning rod)installed on the building or inductive lightning current on the
userspower supply device in real-time. When lightning current occurs, the device can
record the time, times and intensity of the lightning current with no exception.
T03-A2 intelligent lightning peak value recorder has two inquiry modes, that is, live
querying information and sending or receiving information automatically via wireless.
The data of lightning current value recorded in the T03-A2 can be inquired by
engineer's operation on the key of equipment control panel and the data can be
displayed on the LCD. The data will be sent automatically to the receiving computer
for saving and printing via wireless network.
The recorder uses battery for power supply with built-in solar energy maintenance
module, which can be used for more than 5 years continuously without maintenance
under the condition of unmanned intervention. The whole device is encased in a plastic
box, reaching the anti-explosion grade of Increased Safety(explosion proof certified,
EEXD...), with that feature, it can be used to used for lightning arresting devices in the
fields such as high mountains, wild ridges, urban buildings, railway, petrochemical
electric power industries to record lightning current, and thus forming a network system
for lightning monitoring and recording.
T03-A2 Specifications
150
100
Recording channel
Recording signal
Data storage
Type 1: GPS
Recording threshold
1kA
Operating voltage
3.8V/DC10%
Type 2: ZigBee
Power consumption
Type 3 CDMA/GSM/GPRS
Power lifespan
>5 years
Operating mode
Continuous
70
Temperature range
-30C65C
Humidity range
095%
IP65
T03-A2-1
T03-A2-3
Protection grade
Altitude
Signal type
Data display
Dimensions
150mm110mm75mm