Documente Academic
Documente Profesional
Documente Cultură
Medical Power
- Engineered by XP Power
XP Power is a leading international provider of power
solutions to the healthcare equipment market. With over 25%
of revenue coming from healthcare customers, XP has been
providing solutions for well over a decade.
Quality
Medical devices that are used to treat and diagnose
conditions also pose a risk to the patient especially when they
are powered from mains electricity. Such devices have very
stringent safety regulations and they are designed in such a
way so as to mitigate the risk. Medical device manufacturers
are required to abide by strict quality standards to ensure that
each product is manufactured as it was intended to be. As the
power supply typically provides the main safety isolation
barrier between hazardous mains voltages and low voltage
DC, it is essential that steps are taken to ensure any risk is ‘as
low as reasonably practical’ (ALARP).
Manufacturing
Our main manufacturing location is at a facility located in
Kunshan, close to Shanghai, China. The factory provides
around 70,000 sq feet of manufacturing space and is a key
reason why XP can provide low risk power solutions to the
healthcare equipment industry. The facility which is certified to
ISO9001, ISO14001 and ISO13485 delivers manufacturing
capabilities that are truly class leading.
Products
Our customers are constantly trying to differentiate their
products from those of their competitors through enhanced
performance and functionality. In turn, this dynamic creates
demand for power
Above: The recently expanded Kunshan
converters that can satisfy a
manufacturing facility.
very wide range of technical
requirements. Consequently,
Left: High standards and controls
the XP Power research and
maintained throughout the production
development function has
process.
developed, and continues to
improve, the broadest
product portfolio of medically
approved power supplies in
the industry. In addition to
this, the majority of XP
Power products are capable
of being modified specifically
to the customer’s exact
requirements. 02
ORing Set &
Digital Control
have accelerated the rate of ‘green’ product introductions in the last two External power supplies meet Energy Efficiency Level V
years and have created our own 'green power' logo to highlight these requirements as defined below:
particular products to our customers. This logo will be used for the
appropriate products on datasheets and other marketing material. No load power limits
Rated power No load consumption
Here we highlight what we mean by ‘green power’. This definition includes
0 W to <50 W ( 51 W) 0.3 W
the no load power limits and average efficiency limits of our 'green power'
products for both our external power supply range and component power 50 W to 250 W (> 51 W) 0.5 W
supplies.
Active mode power limits, O/P < 6 V
More and more customers are asking us about efficiency and energy Rated power *Average efficiency
consumption. In summary we are focused on developing products that
0 W to 1 W 0.497 x rated power+0.067
are smaller, produce less waste, consume less physical material and avoid
hazardous substances. >1 W to 49 W ( 51 W) [0.0750 x Ln(Rated power)]+0.561
>49 W (>51 W) 0.86
Our goal is to become the leader in our industry on environmental and
sustainability issues. Active mode power limits, O/P ≥ 6 V
Rated power *Average efficiency
Board level Environmental Committee focused on minimizing our
environmental impact 0 W to 1 W 0.48 x rated power+0.14
>1 W to 49 W ( 51 W) [0.0626 x Ln(Rated power)]+0.622
A network of environmental representatives drive local initiative
>49 W (>51 W) 0.87
and awareness
Figures in ( ) are ErP limits. In addition, power supplies with an input power of 100 W
Environmental concerns and legislation drive demand for energy and above must have minimum power factor of 0.9 at 115 VAC 60 Hz.
efficient products
Component power supplies meet the following criteria:
Applicant member of the Electronic Industry Citizenship Coalition
(EICC), full membership expected by April 2011 No load power limits
ISO14001 certified environmental management system Rated power No load consumption
0 W to <250 W 0.5 W
≥250 W No limit
03
*Average efficiency is measured at 25, 50, 75 & 100% load.
Product Overview
Model Name Description No. of Outputs Available Output Voltages (VDC) Output Power (W) Page
04
25 to 150 Watts Open-frame
Single Output
ECSSeries
GREEN•POWER 12.0 VDC 5.00 A ECS60US12
15.0 VDC 4.00 A ECS60US15
24.0 VDC 2.50 A ECS60US24
48.0 VDC 1.25 A ECS60US48
25-100 Watts
12.0 VDC 5.40 A ECS65US12
Medical Safety Approvals 15.0 VDC 4.30 A ECS65US15
18.5 VDC 3.40 A ECS65US18
Ultra compact from 2” x 3” x 0.95” 24.0 VDC 2.70 A ECS65US24
28.0 VDC 2.30 A ECS65US28
<0.5 W No Load Input Power
48.0 VDC 1.40 A ECS65US48
Class I & Class II Installations 12.0 VDC 8.30 A ECS100US12
15.0 VDC 6.70 A ECS100US15
-20 °C to +70 °C Operation
24.0 VDC 4.20 A ECS100US24
3 Year Warranty 28.0 VDC 3.60 A ECS100US28
48.0 VDC 2.10 A ECS100US48
ECPSeries
150 Watts
Medical Safety Approvals
Ultra Compact 2” x 4” x 1.26” Package
Convection-cooled & Forced-cooled Ratings
<0.5 W No Load Input Power
Built-in Fan Supply
3 Year Warranty
GREEN•POWER
05
ECS - Specifications ECS&ECP
Input Series
Input Voltage • 80 to 264 VAC (120 - 370 VDC), derate linearly from 90 VAC to 80% load at 80 VAC
Input Frequency • 47 - 400 Hz
25-150 Watts Open-frame
Input Current • 0.75 A typical at 115 VAC full load, 0.45 A typical at 230 VAC full load The ECS/ECP series has been
Earth Leakage Current • 260 µA at 264 VAC/60 Hz max, 80/160 µA typical 115/230 VAC designed to minimize the no load
No Load Input Power • 25-60 W: <0.3 W, 65-100 W: <0.5 W power consumption (<0.5 W) and
maximize efficiency in order to
Output facilitate equipment design to the
Output Voltage • 5 - 48 VDC (See table) latest environmental legislation.
Output Power • 25 - 80 W convection-cooled, 100 W forced-cooled With its ultra compact footprint of
Minimum Load • No minimum load required 2" x 3" (ECS25, 45 & 60) and
Start Up Delay • 1 s typical 2" x 4" (ECS100 & ECP150) this
product is ideal for applications
General where space is a premium.
Efficiency • 87% typical
Isolation • 4000 VAC Input to Output, 1500 VAC Input to Ground, 500 VDC Output to Ground
Switching Frequency • 65 KHz typical
MTBF • Up to 1072 kHrs to MIL-HDBK-217F at 25 °C, GB
40 & 65 W Multiple Output
Environmental ECP Series Available see page 12
Operating Temperature • -20 °C to +70 °C derate linearly from +50 °C at 2.5%/°C to 50% load at +70 °C.
Cooling • ECS25/45/60/65: convection, ECS100: 80 W convection, 100 W forced-cooled (10 CFM)
Storage Temperature • -40 °C to +85 °C
ECP - Specifications
Input
Input Voltage • 90 to 264 VAC
Input Frequency • 47 - 63 Hz
Output
Output Voltage • 12 - 48 VDC (See table)
Output Power • 100 W convection-cooled, 150 W forced-cooled
Minimum Load • No minimum load required
Start Up Delay • 2 s max
General
Efficiency • 91% typical
Isolation • 4000 VAC Input to Output, 1500 VAC Input to Ground, 500 VDC Output to Ground
Switching Frequency • 60 kHz ±10 kHz
MTBF • >200 kHrs to MIL-HDBK-217F at 25 ºC, GB
Environmental
Operating Temperature • -20 °C to +70 °C, derate from 100% load at 50 °C to 50% load at 70 °C
Cooling • Convection-cooled (100 W), forced-cooled (150 W with 15 CFM)
Storage Temperature • -40 °C to +85 °C
06
140 to 350 Watts Open-frame
Single Output
ECM/CLCSeries
140-175 Watts
EMHSeries
250-350 Watts
Medical Safety Approvals Medical Safety Approvals (BF)
Top Fan Cover Option 250 W / 350 W in 3” x 5” Package
12 V Fan Output 80 V - 275 VAC Operation
5V Standby Option Analog & PMBus Signal Options (EMH350)
Remote On/Off & Power Good Signal Options 5 V Standby (EMH350)
3 Year Warranty 3 Year Warranty
Output Voltage Output Current Model Number Output Voltage Output Current Model Number
PMBus
The power management bus (PMBus)
is an open standard power management
protocol with a fully defined command language that facilities
communications with power converters and other devices in a
power system.
07
ECM & CLC - Specifications ECM/CLC
Input Series
Input Voltage • 85 to 264 VAC
Input Frequency • 47 - 63 Hz
140-175 Watts Open-frame
Input Current • 2.5 A /3.0 A at 115 VAC (140/175), 1.3 A /1.5 A at 230 VAC (140/175) The ECM140/CLC175-M series
Earth Leakage Current • 265 µA max at 264 VAC/60 Hz comes in a compact industry standard
footprint of 3" x 5". Both models
Output achieve excellent efficiency by using a
Output Voltage • 12 - 48 VDC (See table) resonant topology design. The
Output Power • ECM140: 120 W convection, 148 W forced-cooled, CLC175-M: 175 W forced-cooled ECM140 has a convection-cooled
Minimum Load • No minimum load required rating of 120 W and a forced-cooled
Start Up Delay • 1.5 s typical rating of 148 W. The CLC175-M
provides 175 W with forced cooling.
General
Efficiency • 88% typical
Isolation • 4000 VAC Input to Output, 1500 VAC Input to Ground, 500 VAC Output to Ground
Switching Frequency • 70 KHz
MTBF • 220 kHrs / 390 kHrs (ECM140/CLC175) typical to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • 0 °C to +70 °C, derate linearly from 100% power at +50 °C to 50% power at +70 °C
Cooling • ECM140: 120 W convection-cooled, 148 W forced-cooled >10CFM
EMHSeries
CLC175: Forced-cooled >10CFM
Storage Temperature • -40 °C to +85 °C 250-350 Watts Open-frame
Safety & EMC The EMH series is an ultra compact
high power density power supply
Emissions • EN55011/22, level B conducted, EN55011/22, level A radiated
delivering 250 W and 350 W in an
Safety Approvals • EN60601-1, UL60601-1, CSA22.2 No. 601-1 per cUL, EN60950, UL60950
industry standard footprint of
3" x 5". Both models come with
medical BF approvals making them
ideal for patient contact
applications. The EMH350 has a
Output
Output Voltage • 12 - 48 VDC (See table)
Output Power • EMH250: 250 W, EMH350: 350 W
Minimum Load • No minimum load required
Start Up Delay • 1 s typical
General
Efficiency • 87% typical
Isolation • 4000 VAC Input to Output, 1500 VAC Input to Ground, 1500 VAC Output to Ground
Switching Frequency • PFC: 62-560 kHz, Main: 71 kHz, Standby: 50-130 kHz
MTBF • 236 kHrs typical to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • 0 °C to +70 °C, derate linearly from 100% power at +50 °C to 50% power at +70 °C
Cooling • Forced-cooled 12 CFM
Storage Temperature • -40 °C to +85 °C
08
250 Watts Convection-cooled
Single Output
GREEN•POWER GREEN•POWER
CCMSeries CCBSeries
Medical Safety Approvals Medical Safety Approvals (BF)
95% Efficiency Convection-cooled Very High Efficiency Convection-cooled
300 W Peak for 500 ms 300 W peak for 500 ms
Class B Radiated & Conducted Emissions Class B Radiated and conducted emissions
Wide Input Range, 80 - 275 VAC Wide Input Range, 80 - 275 VAC
Compact 4” x 6” U-Channel Compact 4” x 6” Open-frame
Output Voltage Output Current Model Number Output Voltage Output Current Model Number
09
CCM - Specifications CCMSeries
Input 250 Watts U-Channel
Input Voltage • 80 to 275 VAC The CCM250 AC-DC medical grade
Input Frequency • 47 - 63 Hz power supply features industry leading
Input Current • 2.4 A at 115 VAC, 1.2 A at 230 VAC efficiency of 95% and an absolute
minimum efficiency of 90% at 90 VAC
Earth Leakage Current • 250 µA max at 264 VAC/60 Hz
input and full power. The ultra high
Output efficiency is achieved using a half
Output Voltage • 12 - 48 VDC (See table) bridge resonant ZCS topology
Output Power • 250 W continuous, 300 W peak resulting in the highest power
Minimum Load • No minimum load required convection-cooled supply packaged in
a 6" x 4" x 1.5" footprint. This high
Start Up Delay • 1 s typical
efficiency can provide up to 70%
General waste energy savings when compared
Efficiency • Up to 95% to conventional products, making the
Isolation • 4000 VAC Input to Output, 1500 VAC Input to Ground, 500 VAC Output to Ground CCM250 a must have product for
energy efficiency equipment.
Switching Frequency • PFC: 30 to 500 kHz, Boost: 25.6 kHz, Main: 51.2 kHz
MTBF • 365 kHrs typical to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • -20 °C to +70 °C, derate linearly from 100% power at +50 °C to 50% power at +70 °C
CCBSeries
Cooling • Convection-cooled
Storage Temperature • -40 °C to +85 °C
CCB - Specifications
medical BF safety approvals making
this product ideal for applications that
require direct patient contact.
Input
Input Voltage • 80 to 275 VAC
Input Frequency • 47 - 63 Hz
Input Current • 2.4 A at 115 VAC, 1.2 A at 230 VAC
Leakage Current • Earth: 250 µA max at 264 VAC/60 Hz, Patient: 100 µA max
Output
Output Voltage • 12 - 48 VDC (See table)
Output Power • 250 W continuous, 300 W peak
Minimum Load • No minimum load required
Start Up Delay • 1 s typical
General
Efficiency • Up to 95%
Isolation • 4000 VAC Input to Output, 1500 VAC Input to Ground, 1500 VAC Output to Ground
Switching Frequency • PFC: 30 to 500 kHz, Boost: 25.6 kHz, Main: 51.2 kHz
MTBF • 365 kHrs typical to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • -10 °C to +70 °C, derate linearly from 100% power at +50 °C to 50% power at +70 °C
Cooling • Convection-cooled
Storage Temperature • -40 °C to +85 °C
10
40 to 175 Watts Multiple Output
ECMSeries
+5 V 6A +12 V 2.0 A -12 V 0.5 A ECM40UT31
+5 V 6A +24 V 2.0 A -12 V 0.5 A ECM40UT32
+5 V 6A +15 V 1.5 A -15 V 0.5 A ECM40UT33
+3.3V 6A +5 V 1.5 A +12 V 0.5 A ECM40UT34
40-100 Watts +5 V 6A +3.3V 1.5 A +12 V 0.5 A ECM40UT35
Medical Safety Approvals +5 V 8A +12 V 3.0 A ECM60UD21
+5 V 8A +15 V 2.5 A ECM60UD22
High Power Density +5 V 8A +12 V 3.0 A -12 V 0.5 A ECM60UT31
+5 V 8A +24 V 1.5 A -12 V 0.5 A ECM60UT32
Class I and II Construction
+5 V 8A +15 V 2.5 A -15 V 0.5 A ECM60UT33
ECM40/60 Size: 2” x 4” +3.3V 8A +5 V 1.5 A +12 V 0.5 A ECM60UT34
+5 V 8A +3.3V 1.5 A +12 V 0.5 A ECM60UT35
ECM100 Size: 2.5” x 4.5” +5 V 12 A +12 V 3.0 A ECM100UD21
3 Year Warranty +5 V 12 A +15 V 3.0 A ECM100UD22
+5 V 10 A +12 V 3.0 A -12 V 0.8 A ECM100UT31
+5 V 10 A +24 V 2.0 A -12 V 0.8 A ECM100UT32
+5 V 10 A +15 V 3.0 A -15 V 0.8 A ECM100UT33
+3.3V 10 A +5 V 5.0 A +12 V 0.8 A ECM100UT34
+5 V 10 A +3.3V 5.0 A +12 V 0.8 A ECM100UT35
+5 V 10 A +12 V 3.0 A -5 V 0.8 A ECM100UT36
+5 V 10 A +15 V 3.0 A -5 V 0.8 A ECM100UT37
+5 V 10 A +3.3V 5.0 A +12 V 0.8 A -12 V 0.5 A ECM100UQ41
+3.3V 10 A +5 V 5.0 A +12 V 0.8 A -12 V 0.5 A ECM100UQ42
+5 V 10 A +24 V 2.0 A +12 V 0.8 A -12 V 0.5 A ECM100UQ43
+5 V 10 A +24 V 2.0 A +15 V 0.8 A -15 V 0.5 A ECM100UQ44
+5 V 10 A +12 V 3.0 A -12 V 0.8 A -5 V 0.5 A ECM100UQ45
+5 V 10 A +15 V 3.0 A -15 V 0.8 A -5 V 0.5 A ECM100UQ46
+5 V 15 A +12 V 8.3 A RCL175PD22
+5 V 15 A +12 V 6.3 A F12 V 2.0 A RCL175PT31(1)
RCLSeries
175 Watts
+5 V
+5 V
+5 V
15 A
15 A
15 A
+15 V
+3.3V
12 V
4.6 A
15 A
5.5 A
F15 V
F15 V
F5 V
2.0 A
2.0 A
2.0 A
F15 V
F12 V
2.0 A
2.0 A
RCL175PT32(1)
RCL175PQ43(1)
RCL175PQ44(1)
+5 V 15 A 15 V 4.0 A F5 V 2.0 A F15 V 2.0 A RCL175PQ45(1)
+5 V 15 A 24 V 3.2 A F12 V 2.0 A F12 V 2.0 A RCL175PQ46(1)
Medical Safety Approvals
+5 V 15 A 24 V 3.0 A F15 V 2.0 A F15 V 2.0 A RCL175PQ47(1)
200 W Peak Rating
(1) Outputs 3 & 4 are floating, they can be connected externally for positive or
negative output.
Up to 110 W Convection Cooling
Class I & Class II Installations
Connector & Mechanical Options
3 Year Warranty
11
ECM - Specifications ECMSeries
Input 40-100 Watts Open-frame
Input Voltage • 90 to 264 VAC The multiple output ECM series provides
Input Frequency • 47 - 63 Hz, 440Hz a compact medically approved solution
Input Current • ECM40: 0.4 A at 230 VAC, ECM60: 0.6 A at 230 VAC, ECM100: 0.9 A at 230 VAC. with up to 4 outputs. The 40 W & 60 W
models are packaged in a 2” x 4”
Earth Leakage Current • <210 µA max at 230 VAC
footprint, with the 100 W being in a
Output 4.5” x 2.5” package.
Output Voltage • 5 - 24 VDC (See table)
Output Power • 40 W - 100 W
Minimum Load
Start Up Delay
•
•
Required, consult full datasheet
1.5 s RCLSeries
General
Efficiency • 80 - 85% depending on model 175 Watts
Isolation • 4000 VAC Input to Output, 1500 VAC Input to Ground, 500 VAC Output to Ground Approved for class I or class II
Switching Frequency • 70 KHz typical applications, the RCL series provides a
MTBF • 600 kHrs typical to MIL-HDBK-217F at 25 °C, GB multiple output medically approved
Environmental solution with 175 W of output power.
Available with either dual, triple or
Operating Temperature • 0 °C to +70 °C, derate linearly from 100% power at +50 °C to 50% power at +70 °C quad outputs and with fully floating
Cooling • ECM40/60: convection, ECM100: 65-80 W convection, 100 W forced-cooled (5 CFM). outputs the RCL provides a flexible
Storage Temperature • -40 °C to +85 °C solution for any application requiring
Safety & EMC more than one output voltage. The
product also comes with three different
Emissions • EN55011/22, level B conducted, EN55011/22, level A radiated
mechanical options.
Safety Approvals • EN60601-1, UL60601-1, CSA22.2 No. 601-1 per cUL, EN60950, UL60950
RCL - Specifications
Input
Input Voltage • 90 to 264 VAC
Input Frequency • 47 - 63 Hz
Input Current • 2.1 A max at 115 VAC, 0.9 A max at 230 VAC
Earth Leakage Current • 120 µA max at 264 VAC/60 Hz
Output
Output Voltage • 5 - 24 VDC (See table)
Output Power • 175 W continuous, 200 W peak
Minimum Load • Required, consult datasheet GREEN•POWER
ECPSeries
Start Up Delay • 2s
General
Efficiency • 80 - 90% depending on model
Isolation • 4000 VAC Input to Output, 1500 VAC Input to Ground, 500 VAC Output to Ground 40-65 Watts Multiple Outputs
(U-channel) & 1500 VAC Output to Ground (Open-frame)
Switching Frequency • PFC: 75 kHz, PWM: 60 kHz Medical Safety Approvals
MTBF • 385 kHrs typical to MIL-HDBK-217F at 25 °C, GB Low Profile Design
Environmental Ultra Compact Size from 2 x 3.5 x 0.9”
Operating Temperature • -10 °C to +70 °C, derate linearly from 100% power at +50 °C to 50% power at +70 °C
Cooling • Up to 110 W convection, 175 W forced-cooled (12 CFM) Dual and Triple Output
Storage Temperature • -40 °C to +85 °C <0.3 W No Load Input Power
Safety & EMC 3 Year Warranty
Emissions • EN55011/22, level B conducted, EN55011/22, level A radiated
Safety Approvals • EN60601-1, UL60601-1, CSA22.2 No. 601-1 per cUL, EN60950, UL60950
12
400-1500 Watts Enclosed
FCMSeries
400 Watts
Medical Safety Approvals
MHPSeries
400 W Continuous, 600 W Peak
80 V - 275 VAC Operation
650-1200 Watts Integral Low Noise Fan
Medical Safety Approvals 5 V Standby, AC OK and Remote On/Off
End Fan, Top Fan & U Channel Options 3 Year Warranty
AC OK, Remote On/Off and Active Current Share
Load Dependant Variable Speed Fan
Rugged construction
3 Year Warranty
13
MHP - Specifications MHPSeries
Input 650-1200 Watts Enclosed
Input Voltage • 85 to 264 VAC The MHP650 and MHP1000 power
Input Frequency • 47 - 63 Hz supplies provide up to 650 and 1200
Input Current • 115 VAC: 6.5 A/15.1 A (MHP650/1000), 230 VAC: 3.2 A/10.9 A (MHP650/1000) W in two compact packages. The
MHP650 comes with three different
Earth Leakage Current • 250 µA max at 264 VAC/60 Hz
mechanical options (U-channel, end
Output fan and top fan) and the MHP1000
Output Voltage • 12 - 48 VDC (See table) comes with in an end fan mechanical
Output Power • MHP650: 650 W, MHP1000: 1000 - 1200 W (See table) package. Both products employ load
Minimum Load • No minimum load required dependant variable speed fans to
reduce audible noise.
Start Up Delay • 500 ms
General
Voltage Adjust • ±10%
FCMSeries
Efficiency • 85% typical
Isolation • 4000 VAC Input to Output, 1500 VAC Input to Ground, 500 VDC Output to Ground
Switching Frequency • PFC: 70 kHz, Main: 200 kHz
MTBF • 260 kHrs typical to MIL-HDBK-217F at 25 °C, GB
400 Watts Enclosed
Environmental The FCM400 power supply provides
Operating Temperature • -20 °C to +70 °C, derate linearly from 100% power at +50 °C to 50% power at +70 °C
up to 400 W continuous and 600 peak
Cooling • Internal fan cooling or 5.5 m/s with U-Channel
output power for up to 0.5 seconds.
Storage Temperature • -40 °C to +85 °C Packaged in a compact 4" x 6" x 1.9"
Safety & EMC enclosure the FCM400 can easily be
integrated into a wide range of medical
Emissions • EN55011/22, level B conducted, EN55011/22, level A radiated
applications. An integral low noise fan
Safety Approvals • EN60601-1, UL60601-1, CSA22.2 No. 601-1 per cUL, EN60950, UL60950
allows for quiet operation and reduces
the audible noise level of the
power supply.
14
400-2500 Watts Configurable fleXPower
400-2500 Watts
The fleXPower series is a range of
modular power supplies which can be
configured into customer specific
solutions for quick delivery of samples,
prototypes and low volume
production. There are 11 power
platforms in the series ranging from
400 W to 2500 W and 44 modules
with outputs from 3.3 V to 60 V. As the
name suggests this is a very flexible
and rugged product making it ideal for
critical medical applications.
fleXPower
Medical Safety Approvals
Configurable for Fast Time to Market
Rugged Construction
Extra Power Available at High Line
Intelligent Fan Speed Controller
3 Year Warranty
15
External Power GREEN•POWER
AHMSeries
85-250 Watts
The AHM series of medical external
power supplies are fully approved to
international medical safety standards.
The series consists of 5 ranges which
are all convection-cooled and sets the
bar for medical grade externals in
terms of efficiency and environmental
approvals. Each model has Energy
Efficiency Level V, IPX1, smooth case
design, AC cord retainer clip and
come in a compact size.
AHMSeries
15.0 VDC 5.76 A AHM85PS15 (1)
85 Watts
19.0 VDC 4.47 A AHM85PS19 (1)
24.0 VDC 3.54 A AHM85PS24 (1)
85-250 Watts 12.0 VDC 8.33 A AHM100PS12 (1)
15.0 VDC 6.67 A AHM100PS15 (1)
Medical Safety Approvals 19.0 VDC 5.26 A AHM100PS19 (1)
100 Watts
24.0 VDC 4.16 A AHM100PS24 (1)
Energy Efficiency Level V, CEC2008 & EISA 2007 24.0 VDC 3.75 A (7 A peak) AHM100PS24P (1,2)
<0.5 W Standby Power 48.0 VDC 2.08 A AHM100PS48 (1)
12.0 VDC 12.50 A AHM150PS12
Class I (and Class II Models 85 W & 100 W) 15.0 VDC 10.00 A AHM150PS15
150 Watts 19.0 VDC 7.89 A AHM150PS19
IPX1 Smooth Case Design
24.0 VDC 6.25 A AHM150PS24
3 Year Warranty 48.0 VDC 3.13 A AHM150PS48
12.0 VDC 13.50 A AHM180PS12
15.0 VDC 12.00 A AHM180PS15
180 Watts
AHM - Specifications
19.0 VDC 9.47 A AHM180PS19
24.0 VDC 7.50 A AHM180PS24
48.0 VDC 3.75 A AHM180PS48
Input 12.0 VDC 17.50 A AHM250PS12
Input Voltage • 90 to 264 VAC
15.0 VDC 14.66 A AHM250PS15
Input Frequency • 47 - 63 Hz
Input Current • See full datasheet 250 Watts 19.0 VDC 12.63 A AHM250PS19
Earth Leakage Current • 200 µA max at 264 VAC/60 Hz 24.0 VDC 10.41 A AHM250PS24
No Load Input Power • <0.5 W 48.0 VDC 5.21 A AHM250PS48
Output
Output Voltage • 12 - 48 VDC (See table) (1) Add suffix ‘C2’ for Class II classified version.
Output Power • 85 - 250 Watts (2) Peak models are not standard product.
Start Up Delay • 100 - 300 ms typical Contact sales for details and availability
General
Efficiency • 92% typical
AFMSeries
Isolation • 4000 VAC Input to Output, 1500 VAC Input to Ground, 500 VAC
Output to Ground
MTBF • 153 kHrs typical to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • 0 °C to +60 °C, derate linearly from 100% power at +40 °C 45-65 Watts External
to 60% power at +60 °C
Cooling • Convection-cooled Medical Safety Approvals
Storage Temperature • -40 °C to +85 °C
Safety & EMC Energy Efficiency Level V
Emissions • EN55011/22 level B conducted, level B radiated
Safety Approvals • EN60601-1, UL60601-1, CSA22.2 No. 601-1 per cUL, CEC2008 & EISA2007 Compliant
EN60950, UL60950
GREEN•POWER
Optional Class II Versions
16
3-10 Watts DC-DC Converter JHMSeries
3-10 Watts DC-DC Converter
High Isolation The JHM series has been designed to
provide isolation between applied
parts and live parts of a medical
device. The series consists of 3
ranges, JHM03, JHM06 and JHM10.
Each model has reinforced insulation
from primary to secondary, very low
input to output capacitance and
UL/IEC/EN60601-1 safety approvals.
5.0 VDC
12.0 VDC
Output Current
600 mA
250 mA
Model Number
JHM0312S05
JHM0312S12
3 Watts
15.0 VDC 200 mA JHM0312S15
Medical Safety Approvals (10-17 Vin)
±12.0 VDC ±125 mA JHM0312D12
3000 VAC Reinforced Insulation (JHM03/06) ±15.0 VDC ±100 mA JHM0312D15
5.0 VDC 600 mA JHM0324S05
4000 VAC Reinforced Insulation (JHM10) 12.0 VDC 250 mA JHM0324S12
3 Watts
15.0 VDC 200 mA JHM0324S15
2 µA Patient Leakage Current (20-30 Vin)
±12.0 VDC ±125 mA JHM0324D12
Very Low Input to Output Capacitance ±15.0 VDC ±100 mA JHM0324D15
5.0 VDC 1200 mA JHM0612S05
3 Year Warranty 12.0 VDC 500 mA JHM0612S12
6 Watts
15.0 VDC 400 mA JHM0612S15
(10-17 Vin)
±12.0 VDC ±250 mA JHM0612D12
JHM - Specifications ±15.0 VDC ±200 mA JHM0612D15
5.0 VDC 1200 mA JHM0624S05
Input 6 Watts
12.0 VDC 500 mA JHM0624S12
Input Voltage • See table 15.0 VDC 400 mA JHM0624S15
Input Current • 25 A max at 30 V (20-30 Vin)
Patient Leakage Current • 2 µA
±12.0 VDC ±250 mA JHM0624D12
±15.0 VDC ±200 mA JHM0624D15
Output
Output Voltage • 5 - 15 VDC (See table) 5.0 VDC 2000 mA JHM1005S05
Output Power • 3 - 10 Watts 12.0 VDC 833 mA JHM1005S12
Start Up Delay • 5 ms 10 Watts 15.0 VDC 666 mA JHM1005S15
General (4.5-9 Vin) ±5.0 VDC ±1000 mA JHM1005D05
Efficiency • 75% to 89% dependent on model
Isolation • 5000 VAC for 10 ms (IEC60664-1), 4000 VAC for 1 min ±12.0 VDC ±420 mA JHM1005D12
reinforced insulation - JHM10, 3000 VAC for 1 min ±15.0 VDC ±333 mA JHM1005D15
reinforced insulation - JHM03/06 5.0 VDC 2000 mA JHM1012S05
Switching Frequency • 180kHz to 1.6MHz variable
12.0 VDC 833 mA JHM1012S12
MTBF • >1 MHrs typical to MIL-HDBK-217F at 25 °C, GB
10 Watts 15.0 VDC 666 mA JHM1012S15
Environmental
Operating Temperature • -20 °C to +100 °C, derate linearly from 100% load at (9-18 Vin) ±5.0 VDC ±1000 mA JHM1012D05
+60 °C to no load at +100 °C ±12.0 VDC ±420 mA JHM1012D12
Cooling • Convection-cooled ±15.0 VDC ±333 mA JHM1012D15
Storage Temperature • -40 °C to +100 °C
5.0 VDC 2000 mA JHM1024S05
Safety & EMC
Emissions • EN55011/22 level A conducted & radiated with no external 12.0 VDC 833 mA JHM1024S12
components 10 Watts 15.0 VDC 666 mA JHM1024S15
Safety Approvals • EN60601-1, UL60601-1, CSA22.2 No. 601-1 per cUL, (18-36 Vin) ±5.0 VDC ±1000 mA JHM1024D05
EN60950, UL60950
±12.0 VDC ±420 mA JHM1024D12
±15.0 VDC ±333 mA JHM1024D15
17
Quick Reference
Safety Approvals IEC60601-1 3rd Edition
IEC60601-1:2005 (3rd Edition) Guidance Major Impact of 3rd Edition
• General requirements for design process
The latest version of 60601-1 is the 3rd edition which was first published in December 2005. The standard to include risk management process in
has been adapted in the major countries/regions of the world and published as the following versions: accordance with ISO14971.
EU: EN60601-1:2005 • Safety has been broadened from basic
USA: ANSI/AAMI ES 60601-1:2005 safety to include essential performance.
Canada: CSA-C22.2 No. 60601-1:08 • Collateral standards IEC60601-1-1 and
IEC60601-1-14 have been inserted into
Currently equipment can be approved to either the 2nd or 3rd editions of the standard, but in June 2012 in
clause 14 and clause 16 of 3rd edition.
the EU the 2nd edition will be withdrawn and all equipment, both new and old, will need to be approved to
3rd edition. In the USA the withdrawal date is June 2013. • Distinction now made between operator
and patient with introduction of MOOP
(Means of Operator Protection) and MOPP
Emission and Immunity Specifications (Means Of Patient Protection). Broadly
MOOP follows IEC60950 and MOPP
IEC55011/55022 Limits for conducted and radiated emissions follows 60601-1 2nd edition. In either
IEC61000-3-2 Limits for harmonic current emissions case 2 x MOP (Mean Of Protection) must
IEC61000-3-3 Limitation of voltage changes, voltage variations & flicker be present under normal conditions.
IEC61000-4-2 Electrostatic discharge immunity XP Power Plan for 3rd Edition Approval
IEC61000-4-3 Radiated immunity • All current medical grade power supplies
IEC61000-4-4 Electrical fast transient immunity approved to 2nd edition will be re-
IEC61000-4-5 Electrical surge immunity approved to 3rd edition by June 2012
(consult sales for detailed plan).
IEC61000-4-6 Conducted disturbance immunity
• All medical grade power supplies will
IEC61000-4-8 Immunity to power frequency magnetic field
comply with MOPP (Means Of Patient
IEC61000-4-11 Immunity to voltage dips, short interruptions and variations on supply line Protection).
• To address Risk Management XP has
Isolation & Separation - IEC60601-1:2005 implemented Risk Management as part of
the design process in accordance with
ISO14971 and factory QMS upgraded
MOOP MOPP to ISO13485.
Insulation
Air Creepage Test Air Creepage Test
Clearance Distance Voltage Clearance Distance Voltage
Basic
2.0 mm 3.2 mm 1500 VAC 2.5 mm 4.0 mm 1500 VAC
(1 x MOP)
Double or Reinforced
4.0 mm 6.4 mm 3000 VAC 5.0 mm 8.0 mm 4000 VAC
(2 x MOP)
Insulation test voltages based on 250 VAC working voltage. MOP = Means of protection
MOOP = Means of operation protection MOPP = Means of patient protection.
Leakage Currents
Earth leakage Current flowing in the earth conductor.
Enclosure leakage Current flowing to earth via the patient from the enclosure.
Patient leakage Current flowing to earth via the patient from an applied part.
Patient auxiliary Current flowing between two applied parts.
Enclosure 100 µA 500 µA* 100 µA 500 µA* 100 µA 500 µA*
18
the US is 300 µA. Figures quoted are for portable equipment. Council ®, meaning they are
ethically minded and the paper is
from responsible sources.
North American HQ
XP Power
990 Benecia Avenue, Sunnyvale, CA 94085
Phone : +1 (408) 732-7777
Fax : +1 (408) 732-2002
Email : nasales@xppower.com
European HQ German HQ
XP Power XP Power
Horseshoe Park, Pangbourne, Auf der Höhe 2, D-28357
Berkshire, RG8 7JW Bremen, Germany
Phone : +44 (0)118 984 5515 Phone : +49 (0)421 63 93 3 0
Fax : +44 (0)118 984 3423 Fax : +49 (0)421 63 93 3 10
Email : eusales@xppower.com Email : desales@xppower.com
Asian HQ
XP Power
401 Commonwealth Drive, Haw Par Technocentre,
Lobby B #02-02, Singapore 149598
Phone : +65 6411 6900
Fax : +65 6741 8730
Email : apsales@xppower.com
Web : www.xppowerchina.com / www.xppower.com
Distributors
Australia ...................+61 2 9809 5022 Amtex
Balkans ....................+386 1 583 7930 Elbacomp
Czech Rep. ............+420 235 366 129 Vums Powerprag
Czech Rep. ............+420 539 050 630 Koala Elektronik
Estonia.........................+372 6228866 Elgerta
Greece ...................+30 210 240 1961 ADEM Electronics
Hungary .....................+36 1 705 2345 JAMSoft
India ............+91 80 4095 9330/31/32 Digiprotech
Israel .........................+972 9 7498777 Appletec
Israel ...................+972 (0)73 7001212 Cidev
Japan.......................+81 48 864 7733 Bellnix
Korea .......................+82 31 422 8882 Hanpower
Latvia .........................+371 67501005 Caro
Lithuania ...................+370 5 2652683 Elgerta
Poland ......................+48 22 8627500 Gamma
Portugal ..................+34 93 263 33 54 Venco
Romania ..................+4 0348 730 920 Multichron T.L.
Russia ....................+7 (495)234 0636 Prosoft
Russia ....................+7 (812)325 5115 Gamma
South Africa .............+27 11 453 1910 Vepac
Spain ......................+34 93 263 33 54 Venco
Taiwan.......................+886 3 3559642 Fullerton Power
Turkey ....................+90 212 465 7199 EMPA