Sunteți pe pagina 1din 3

Internal use only

R 01088.01-01V1.0

Notification of Version Upgrade


R&D Institute

Wireless Product Line

Product Name

ZXMW PR10

Name of Old Version

V2.01.000bP001

Name of New Version

V2.01.000bP002

Time Requirement
Upgrade

of

Version

Instructor of Version Upgrade

Product
Customer
Service
Dept:
the
product CSD

Wireless Network Service Center

30 Minutes
Lichanguo

TEL:

0086-029-88459963

Remark
When use this version, please install the NetNumen U31 R18 V12.12.30 version or above.

Chapter 1 ZXMW-IDU Software Version NewlyAdded/Modified Functions


Relative to PR10-S400S500-V2.01.000bP001 Version
Number

Support or Not

Function Description

YorNorO

Remarks

NA

Chapter 2 ZXMW-IDU Software Version Corrected


Bugs
Relative to PR10-S400S500-V2.01.000bP001 Version
Number

Subject
QoS
when

Description

Workaround

Severity

failure
Frame

length

is

bigger than 256

Verify whether
The

problem

of

software code

To modify
code

the

normally with
length

VLAN

The

Configuration

software code

changed

QoS is running
variety of frame

bits
2

Remarks

after

problem

of

To modify
code

the

Verify whether
VLAN
configuration

< Confidential and Proprietary Information of ZTE CORPORATION>


1

Internal use only


Number

Subject

Description

Workaround

Severity

Remarks

changed after
equipment

equipment reboot

reboot

by cold & warm


way
Set a hop of PR10
equipment with

Anomalous
3

control

frame

detected

from

ETH

normal service

flow

service

flow. Then switch

Chip

To modify the
chip
configuration

configuration
problem

off the remote


end, to check
whether there is

port

flow control
frame detected on
the near end.
Connected PR10 EMS
port with S200 or

Problem of
4

PR10&S200 EMS
ports
interconnection

Auto-negotiation
problem

of

EMS

ports

To modify the
Autonegotiation
mechanism of
chip

others

Equipments

EMS ports in the


mode

of

forced

10M,

to

verify

whether

the

transmission

is

normal.
Poor welding
condition occurs
after prolonged
5

S400

5V

Power

down

use of 5V power
supply module.

Software
reconfigures
logic register

The radio port

Set a poor welding


condition

to

verify

cant be
detected.
The signal
release failure
6

S500 SPI write

is possible in

failure

some undefined

Set the signal


To
add
detection
recovery
mechanism

the
&

recovers

situation.
EMS access

Memory

failure by

distribution

layer 2 network

problem

management

manually, and
check whether it

special
7

release failure

automatically.
To
add
detection
recovery
mechanism

the
&

Whether EMS access

network

failure by layer 2

using

network management

network

occurs in network

management

with large number

being

of devices.

recommended

L2

to

upgrade

to

this

< Confidential and Proprietary Information of ZTE CORPORATION>


2

Internal use only


Number

Subject

Description

Workaround

Severity

Remarks
version

Chapter 3 ZXMW-IDU Software Version Left Bugs


Number

Subject

Description

The display of

The display of

Partner Flow

Partner Flow Control

Control in QoS
1

interface isnt
correct in some
undefined special
situation.

Chapter

Workaround

in QoS interface
isnt correct in
some undefined
special situation.

Notes

for

No

need

situation
any

Remarks

to

avoid.

doesnt
impact

functionality

This
make
to

of

the

device.

Software

Version

Compatibility
1.

In one hop, the software in both ends equipment must be the same. PR10 V2.00 and V2.01 hardware are supported by
this version. PR10 V2.00 and V2.01 hardware can be used in the same network.

2.

Support ODU version of A300 & C100

Approval Comments: Agree


Signature: Pu Suqin

< Confidential and Proprietary Information of ZTE CORPORATION>


3

S-ar putea să vă placă și