Sunteți pe pagina 1din 82

WEBSITE

E-MAIL

http://biz.LGservice.com
http://www.LGEservice.com/techsup.html

Room Air Conditioner


SERVICE MANUAL
CAUTION
-BEFORE SERVICING THE UNIT, READ THE SAFETY
PRECAUTIONS IN THIS MANUAL.
-ONLY FOR AUTHORIZED SERVICE PERSONNEL.

MODEL : LS-Q076ABL/BBG/BEL/ABG
LS-Q096ABL/BBG/BEL/AEL
LS-Q096ACG/ADG/ADL/BDL
LS-Q096AHG/ABG/ABM/AEM
LS-Q096BAG/BDG
LS-Q096ACL/AAG
LS-Q082BAG/BAM
LS-Q082AAL/ACG/ACL/ACM
LS-H096QNA0
LS-Q096BEG
LS-C082QMA0/QNA0
LS-C096QLA0/QNA0
LS-C096QGL0
LS-H096QGL1

Contents
Details of LG Model Name(2002) .......................................................................................... 3
Details of LG Model Name(2003) .......................................................................................... 4
Functions ................................................................................................................................ 5
Product References .............................................................................................................. 8
Dimensions ........................................................................................................................... 10
Refrigeration Cycle Diagram ............................................................................................... 13
Wiring Diagram..................................................................................................................... 14
Operation Details ................................................................................................................. 15
Display Function .................................................................................................................. 22
Self-diagnosis Function....................................................................................................... 22
Installation ............................................................................................................................ 23
Operation .............................................................................................................................. 34
Disassembly of the parts (Indoor Unit) .............................................................................. 36
2-way, 3-way Valve................................................................................................................ 39
Cycle Troubleshooting Guide.............................................................................................. 46
Electronic Parts Troubleshooting Guide............................................................................ 47
Electronic Control Device.................................................................................................... 54
Schematic Diagram .............................................................................................................. 59
Exploded View and Replacement Parts List...................................................................... 64

-2-

Details of LG Model Name(2002)


1
Code

Type

Code of Model

Meaning

1,2

Type of Airconditioner

A~Z

LS: LG Split Type Airconditioner

Chassis

A~Z

4,5

Capacity(Btu/h)

1~9

Name of toll of Unit


Ex. LS-R S R Chassis
Cooling/Heating Capacity
Ex. "09" 9,000Btu/h

Electric Range

1~9

Serial No.

0~9
A~Z

Cooling/Heating

A~Z

LG/OEM Brand

A~Z

Electric Standard
1 115V/60Hz
2 220V/60Hz
3 208~230V/60Hz
5 200~220V/50Hz

6 220~240V/50Hz
7 110V, 50/60Hz
8 380~415V/50Hz
9 380~415V/60Hz

Basic
Plasma Filter
Auto Swing + Plasma Filter
Telephone + LED Display
Telephone + LCD Display
Auto Swing + Plasma Filter + Telephone + LCD
Low Ambient + Ambient/change
Plasma Filter + Low Ambient + Ambient/change
Internet
Auto Swing + Plasma Filter + Oxygen Generator
Auto Swing + Soft Start
Auto Swing + Star Rating
Auto Swing + Star Rating + Plasma Filter
Auto Swing + Soft Start + Star Rating
Auto Swing + Soft Start + Star Rating 4 + Plasma
Auto Swing + Telephone + LCD
Auto Swing + Telephone + LCD + Soft Start
UNIT

R22

HFC

R22+AC INV.

INDOOR

OUTDOOR

C/O

H/P

C/O

H/P

BASIC

BASIC

BASIC

GOLD FIN

PLASMA

GOLD FIN

PLASMA

BASIC

GOLD FIN

GOLD FIN

L: LG Brand
G: 2nd LG Brand

-3-

H/P E/H+C/O E/H+H/P C/O

A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S

M: 1st OEM Brand


N: 2nd OEM Brand

0
1
2
3
4
5
6
7
8
9
Z
Y
X
W
V
U
T
HFC+AC HFC+DC
INV.
INV.
H/P H/P

Details of LG Model Name(2003)~


1
Code

Type

Code of Model

10

Meaning

Producing Center,
Refrigerant

A~Z

L: Chang-won R22
A: Chang-won R410A
C: Chang-won R407C
T: China
K: Turkey R22
E: Turkey R410A
H: Thailand

N: India
Z: Brazil
D: Indonesia
M: Mexico
V: Vietnam
S: Out Sourcing

Product Type

A~Z

S: Split Type Air Conditioner

Cooling/Heating/Inverter

A~Z

C: Cooling only
H: Heat pump
X: C/O + E/Heater
Z: H/P + E/Heater

4, 5

Capacity

0~9

Cooling/Heating Capacity
Ex. "09" 9,000 Btu/h

Electric Range

1~9
A~Z

1: 115V/60Hz,
2: 220V/60Hz
3: 208-230V/60Hz
5: 200-220V/50Hz
6: 220-240V/50Hz
7: 110V, 50/60Hz
8: 380-415V/50Hz
9: 380-415V/60Hz

Chassis

A~Z

Name of Chassis of Unit


Ex. LSP SP Chassis

Look

A~Z

Look,
Color (Artcool Model)

Function

A~Z

10

Serial No.

1~9

V: AC Inverter C/O
N: AC Inverter H/P
Q: DC Inverter C/O
W: DC Inverter H/P

A: 220V, 50Hz, 3Phase


B: 208~230V, 60Hz, 3Phase
C: 575V, 50Hz, 3Phase
D: 440~460, 60Hz, 3Phase
E: 265V, 60Hz
F: 200V, 50/60Hz

Basic
Basic+4Way
Plasma Filter
Plasma Filter+4 Way
Tele+LCD
Tele+LCD+Nano plasma+4Way
Nano Plasma F+(A/changeove)+A/clean+Low A
Nano Plasma F+(A/changeove)+A/clean+4way+Low A
Tele+LED+4way
Internet
Plasma F+4Way+Oxy generator
Nano Plasma F+(A/changeove)+A/clean
Nano Plasma F+(A/changeove)+A/clean+4way
Nano Plasma F+(A/changeove)+A/clean+PTC
Nano Plasma F+(A/changeove)+Autoclean+4way+PTC
Nano Plasma F+(A/changeove)+A/clean+4way+Low A+PTC
Negative ION+A/Clean
(Nano)Plasma+Negative ION+A/Clean
4way+(Nano)Plasma F+Negative ION+Healthy dehumidification+A/Clean
Nano Plasma F+4Way+(A/changeove)+A/clean+
LG Model Development Serial No.
* ARTCOOL COLOR
R
Mirror
W
White
B
Blue
D
Wood
M
Metal
C
Cherry

-4-

A
B
C
D
E
F
G
H
I
J
K
L
M
N
P
Q
R
S
T
U

Functions
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature sensor. (THERMISTOR)
Room temperature control
Maintains the room temperature in accordance with the Setting Temp.
Starting Current Control
Indoor fan is delayed for 5 sec at the starting.
Time Delay Safety Control
Restarting is inhibited for approx. 3 minutes.
Indoor Fan Speed Control
High, Med, Low, CHAOS, JET COOL
Operation indication Lamps (LED)
--- Lights up in operation
--- Lights up in Sleep Mode
--- Lights up in Timer Mode
--- Lights up in Defrost Mode (for Heating Model)
OUTDOOR--- Lights up in compressor operation (for Cooling Model)
PLASMA

--- The function illustrates its dynamic mode


by using a multiple lighting system.
(

--- Linghts up in Telephone Control operation.


PLASMA

Soft Dry Operation Mode

The function will be operated while in any


operation mode with selecting the function.
The function is to be stopped while it is
operating with selecting the function.

Intermittent operation of fan at low speed.


Sleep Mode Auto Control
The fan is switched to low(Cooling), med(Heating) speed.
The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.

Defrost(Deice) control (Heating)


Both the indoor and outdoor fan stops during defrosting.

Natural Air Control by CHAOS Logic


The fan is switched to intermittent or irregular operation
The fan speed is automatically switched from high to low speed.
Airflow Direction Control
The louver can be set at the desired position or swing
up and down automatically.
-5-

Hot-start Control (Heating)


The indoor fan stops until the
evaporator pipe temperature will be reached
at 28C.

Remote Control
Operation ON/OFF

Operation Mode Selection


Cooling Operation Mode.(
(Cooling
(Heating
model only) model only)

Healthy Dehumidification Operation Mode.(

Auto Operation Mode.(

) Heating Operation Mode.(

Fan Speed Selection


(Low)

(Med)

(High)

(CHAOS)

Room, Temperature Display


: (High:39C

Low:11C)

Temperature Setting
TEMPERATURE

LOW

HIGH

Cooling

Down to 18C
Up to 30C

Heating

JET COOL

PLASMA(Optional)
PLASMA

Setting the Time or Timer

Timer Selection
ON

OFF

: OFF, ON, OFF

ON

Timer Setting
SET

Timer Cancel
CANCEL

: Cancel Sleep Mode, Timer ON or Timer OFF

Sleep Operation
: 1, 2, 3, 4, 5, 6, 7, Off Timer
Airflow Direction Control

Fan Operation Mode


: Fan Operates without cooling or heating.
Horizontal Airflow Direction Control Button(Optional)

Reset
-6-

Down to 16C
Up to 30C

Remote Control
Operation ON/OFF

Operation Mode Selection


Cooling Operation Mode.(
(Cooling
(Heating
model only) model only)

Healthy Dehumidification Operation Mode.(

Auto Operation Mode.(


) Heating Operation Mode.(

)
)

Fan Speed Selection


(Low)

(Med)

(High)

Room, Temperature Checking

: (High:39C

Low:11C)

Temperature Setting
TEMPERATURE

LOW

HIGH

Cooling

Down to 18C
Up to 30C

Heating

JET COOL

PLASMA(Optional)

Setting the Time or Timer

Timer Selection
ON

OFF

: OFF, ON, OFF

ON

Timer Setting
SET

Timer Cancel
CANCEL

: Cancel Sleep Mode, Timer ON or Timer OFF

Sleep Operation

: 1, 2, 3, 4, 5, 6, 7, Off Timer
Airflow Direction Control

Air Circulation

: Fan Operates without cooling or heating.


Horizontal Airflow Direction Control Button(Optional)

2nd F
Reset

-7-

Down to 16C
Up to 30C

Product References
Model Name
Item

Unit

Cooling Capacity

Btu/h

Heating Capacity
Moisture Removal

l/h

Power Source
Air Circulation

, V, Hz
Indoor
Outdoor

Noise Level

Indoor
Outdoor

Input

Cooling
Heating

Running

Cooling

Current

Heating

E.E.R.

Cooling

C.O.P

Heating
Indoor

Motor Output
Dimensions
(W x H x D)

m3/min

Outdoor

dB (A)3

W
A
Btu/hW

Indoor
Outdoor

mm

Indoor
Net. Weight

Outdoor

Refrigerant

kg
g

Airflow Direction Control (Up & Down)

LS-Q076BBG
LS-Q076BEL
LS-Q076ABL
LS-Q076ABG

LS-Q096BAG, LS-Q096ACG
LS-Q096ACL, LS-Q096AAL
LS-Q096ADG, LS-Q096ADL
LS-Q096BDG, LS-Q096BDL
LS-Q096AAG

LS-Q096BBG, LS-Q096BEL
LS-Q096AHG, LS-Q096ABL LS-Q082BAG/BAM
LS-Q096ABG, LS-Q096AEL LS-Q082AAL/ACG
LS-Q096ABM, LS-Q096AEM LS-Q082ACL/ACM
LS-Q096BEG

7,000

9,000

9,000

8,000

8,500

7,300

9,300

8,750

1.0

1.0

1.0

1.0

1.0

1, 220V, 60Hz

1, 220-240V, 50Hz

1, 220-240V, 50Hz 1, 220-240V, 50Hz 1, 220-240V, 50Hz

LS-H096QNA0

5.9

20

20

25

20

25

34

36

36

36

36

48

48

48

48

48

660

900

900

650

950

640

870

860

3.0

4.0

3.9

3.0

4.2

2.9

3.8

3.8

10.6

10

10

10

8.9

3.3

3.13

2.8

5.7

5.7

7.6

8.4

14

14.5

14.5

18.7

13.6

824 x 260 x 155 824 x 260 x 155 824 x 260 x 155 824 x 260 x 155 824 x 260 x 155
525 x 564 x 265 525 x 564 x 265 770 x 540 x 245 525 x 564 x 265 770 x 540 x 245
7

23

23

33

23

23

610(R22)

530(R22)

640(R22)

630(R22)

680(R22)

L.C.D Wireless L.C.D Wireless L.C.D Wireless L.C.D Wireless L.C.D Wireless

Remocon Type
Liquid

1/4" (6.35)

1/4" (6.35)

1/4" (6.35)

1/4" (6.35)

1/4" (6.35)

3/8" (9.52)

3/8" (9.52)

3/8" (9.52)

3/8" (9.52)

3/8" (9.52)

Sleeping Operation

Drain Hose

Connecting Cable

0.75mm2

0.75mm2

0.75mm2

0.75mm2

0.75mm2

Power Cord

0.75mm2

0.75mm2

0.75mm2

0.75mm2

0.75mm2

Service Valve

Gas

inch(mm)

NOTE: Please refer to Label Quality on the product since this specification may be changed for improving
performance

-8-

Model Name
Item

LS-C096QLA0
QNA0/QGL0

LS-C082QMA0/QNA0

LS-H096QGL1

Unit
9,000

8,000

9,000

9,300

l/h

1.0

1.0

1.0

, V, Hz

1, 220-240V, 50Hz

1, 220V, 60Hz

1, 220-240V, 50Hz

20

20

25

36

36

36

48

48

48

900

650

950

860

4.0

3.0

4.2

3.8

10

10

9.5

2.8

5.7

7.6

8.4

14.5

18.7

13.6

824 x 260 x 155

824 x 260 x 155

824 x 260 x 155

525 x 564 x 265

525 x 564 x 265

770 x 540 x 245

23

23

23

530(R22)

630(R22)

680(R22)

L.C.D Wireless

L.C.D Wireless

L.C.D Wireless

1/4" (6.35)

1/4" (6.35)

1/4" (6.35)

3/8" (9.52)

3/8" (9.52)

3/8" (9.52)

Sleeping Operation

Drain Hose

Connecting Cable

0.75mm2

0.75mm2

0.75mm2

Power Cord

0.75mm2

0.75mm2

0.75mm2

Cooling Capacity

Btu/h

Heating Capacity
Moisture Removal
Power Source
Air Circulation

Indoor
Outdoor

Noise Level

Indoor
Outdoor

Input

Cooling
Heating

Running

Cooling

Current

Heating

E.E.R.

Cooling

C.O.P

Heating
Indoor

Motor Output
Dimensions
(W x H x D)

m3/min

Outdoor

dB (A)3

W
A
Btu/hW

Indoor
Outdoor

mm

Indoor
Net. Weight

Outdoor

Refrigerant

kg
g

Airflow Direction Control (Up & Down)


Remocon Type
Liquid
Service Valve

Gas

inch(mm)

NOTE: Please refer to Label Quality on the product since this specification may be changed for improving
performance

-9-

Dimensions
(1) Indoor Unit

D
W

Installation plate

MODEL
DIM

All Models

Unit

mm

824

mm

260

mm

155

-10-

(2) Outdoor Unit


L2

L1

L3

Liquid side
(2-way valve)

L4

L5

Gas side
(3-way valve)

MODEL
7k Heat Pump, 8k Cooling, 9k Cooling
DIM

unit

mm

564

mm

525

mm

265

L1

mm

294

L2

mm

66

L3

mm

374

L4

mm

17

L5

mm

270

-11-

(3) Outdoor Unit

L2

L1

L3

L5

Gas side
(3-way valve)

L4

Liquid side
(2-way valve)

DIM

MODEL
unit

9k Heat Pump

mm

770

mm

540

mm

245

L1

mm

285

L2

mm

65

L3

mm

518

L4

mm

10

L5

mm

100

-12-

Refrigeration Cycle Diagram


(1) Cooling Only Models
INDOOR UNIT

OUTDOOR UNIT
LIQUID SIDE
CAPILLARY TUBE

HEAT
EXCHANGE
(CONDENSER)

HEAT
EXCHANGE
(EVAPORATOR)

GAS SIDE

COMPRESSOR

(2) Cooling & Heating Models


INDOOR UNIT

OUTDOOR UNIT
CHECK VALVE
(Heating Model only)

LIQUID SIDE
VALVE

CAPILLARY TUBE
HEAT
EXCHANGE
(EVAPORATOR)

HEAT
EXCHANGE
(CONDENSER)

GAS SIDE
VALVE

REVERSING
VALVE
(Heating Model Only)

ACCUMU
LATOR
COMPRESSOR

-13-

COOLING
HEATING

Wiring Diagram
(1) Indoor Unit

S/W2

FUSE
250V T2A

GN/YL

BK
BK

RD AIR
BK CLEAN
(PLASMA)
BK
BK
S/W1

BK
BK

BK
BK

H.V.
ASM.

MOTOR
BR

CN-TH

CN-AC/DC

STEP
MOTOR

STEP
MOTOR

BK

YL

SH-CAPA

S/W2

CN-DISP

CN-MOTOR
CN-TAB1

RD AIR
H.V.
ASM BK CLEAN
(PLASMA)

FUSE
250V T2A

RY-COMP
T/BLOCK

BK
BK

SAFETY S/W1

BK
BK

SAFETY S/W2

CN-DISP
DISPLAY PWB ASM.

INDOOR WIRING DIAGRAM

DISPLAY PWB ASM.

TO OUTDOOR UNIT

P/No : 3854A20238H

BR
BL
GN/YL

BR
BL
GN/YL

BR
BL
GN/YL
BK
RD

RY-FAN

TO OUTDOOR UNIT

CN-AC/DC

CN-ACDC2

RY-COMP

TRIAC

OR
STEP
MOTOR

THERMISTOR

CN-U/D

BK
BK

T-BLOCK

DC PWB ASM

CN-L/R

BK
BK

POWER

POWER

BK
BK

T/BOARD
CN-TAB

CN-DISP

RY-4WAY

CN-MOTOR

YL

STEP
MOTOR

1(L) 2(N)

FUSE
250V T2A

GN/YL

RY-COMP

BK

SH-CAPA

RD AIR
BK CLEAN
(PLASMA)
BK
BK
S/W1

H.V.
ASM.

BR

1(L) 2(N)

1(L) 2(N)

T-BLOCK

STEP
MOTOR

MOTOR

AC PWB ASM

THERMISTOR

GN/YL
BR(BK/Plained)
BL(WH/Ribbed)

T/BOARD
CN-TAB

CN-CONT CN-12V CN-HVB

SH-CAPA

GN/YL

STEP
MOTOR

3. LS-Q082BAG, LS-Q096ACL, LS-Q082AAL


LS-Q082ACG, LS-Q082ACL, LS-Q082ACM
LS-C082QMA0, LS-C082QNA0

DC PWB ASM.
CN-L/R CN-U/D CN-TH

YL

TRIAC

CN-CONT CN-12V CN-HVB

CN-MOTOR
BR

AC PWB ASM.
OR

CN-ACDC1

BK

THERMISTOR

BR(BK/Plained)
BL(WH/Ribbed)

MOTOR

BL(WH/Ribbed)

BR(BK/Plained)

GN/YL

CN-ACDC2

TRIAC

2. LS-Q096AAG, LS-Q096AAL, LS-Q096ACG


LS-Q096ADL, LS-Q096ADG, LS-Q096BAG
LS-Q096BAG, LS-Q096BDG, LS-Q096BDL
LS-Q082BAM, LS-C096QGL0, LS-C096QLA0,
LS-C096QNA0, LS-H096QGL1

DC PWB ASM.
CN-ACDC1

AC PWB ASM.
OR

CN-L/R CN-U/D CN-TH

POWER

1. LS-Q076ABL, LS-Q076BBG, LS-Q076BEL


LS-Q096ABL, LS-Q096ABG, LS-Q066AHG
LS-Q096AEL, LS-Q096BBG, LS-Q096ABM
LS-Q096AEM, LS-H096QNA0, LS-Q096BEG

TO OUTDOOR UNIT

INDOOR WIRING DIAGRAM

P/No : 3854A20238J

SW(FORCE)
DISPLAY PWB ASM

INDOOR WIRING DIAGRAM

3854A20142B

(2) Outdoor Unit


1. LS-Q076ABL, LS-Q076ABG,
LS-Q076BBG
LS-Q076BEL

2. LS-Q096AAG, LS-Q096AAL,
LS-Q096ACG, LS-Q096ADL,
LS-Q096ADG, LS-Q096ACL
LS-Q096BAG, LS-Q096BDG,
LS-Q096BDL LS-Q082BAG,
LS-Q096ABM, LS-Q082AAL
LS-Q082BAM, LS-Q082ACG,
LS-Q082ACL, LS-Q082ACM
LS-C082QMA0, LS-C082QNA0
LS-C096QCL0, LS-C096QLA0
LS-C096QNA0, LS-H096QGL1

BL

BL
CAPACITOR
H

RD
R

COMP

BL

BK

RD

COMP

FAN
MOTOR

GN/YL

BL

CAPACITOR

BL
BL

BL

C S R

BL

PTC

COMP

CAPACITOR
RD

OLP

RD
R

3. LS-Q096ABL, LS-Q096AEL,
LS-Q096ABG, LS-Q096AHG,
LS-Q096BBG, LS-Q096BEL
LS-Q096ABM, LS-Q096AEM,
LS-Q096BEG

RD BL YL

GN/YL

GN/YL

BR

BR RD BL

BR

BK(RD)

BR

BK

OLP

FAN
MOTOR

FAN
MOTOR

BR(YL)

YL

RD

REVERSING
VALVE

REVERSING
VALVE

OLP

YL

BL
YL

1
BR

BR

BL GN/YL BK

1(L) 2(N)

BR

RD

PILLAR
TERMINAL

1(L) 2(N)

1(L) 2(N)

PILLAR
TERMINAL

BR

BR

BL GN/YL BK

BLACK

BR

RD

GRAY

BL GN/YL BK(RD)

YL

BL GN/YL

BL GN/YL

BK

TERMINAL
BLOCK

RD

BL GN/YL

BLACK

TO INDOOR UNIT

TO INDOOR UNIT

TO INDOOR UNIT

OUTDOOR WIRING DIAGRAM


3854AR2262E

OUTDOOR WIRING DIAGRAM

OUTDOOR WIRING DIAGRAM

3854A30077D

3854AR2262F

-14-

4. LS-H096QNA0, LS-H096QNA0

Operation Details
1. MAIN UNIT FUNCTION
DISPLAY
1) C/O Model
Operation Indicator
ON while in appliance operation, OFF while in appliance pause.
Flashing while in disconnection or short in Thermistor. (3 sec off / 0.5 sec on)
Sleep Timer Indicator
ON while in sleep timer mode, OFF when sleep timer cancel or appliance operation pause.
Timer Indicator
ON while in timer mode (on/off), OFF when timer mode is completed or canceled.
Comp. Running Incidator
While in appliance operation, ON while in outdoor unit compressor running, OFF while in compressor off.
2) H/P Model
Operation Indicator
ON while in appliance operation, OFF while in appliance pause.
Flashing while in disconnection or short in Thermistor. (3 sec off / 0.5 sec on)
Sleep Timer Indicator
ON while in sleep timer mode, OFF when sleep timer cancel or appliance operation pause.
Timer Indicator
ON while in timer mode (on/off), OFF when timer mode is completed or canceled.
Defrost Indicator
OFF except when hot start during heating mode operation or while in defrost control.

Cooling Mode Operation


When the intake air temperature reaches 0.5C below the setting temp, the compressor and the outdoor fan
stop.
When it reaches 0.5C above the setting temp, they start to operate again.
Compressor ON Temp
Setting Temp+0.5C
Compressor OFF Temp
Setting Temp-0.5C
While in compressor running, operating with the airflow speed set by the remote control. While in compressor
not running, operating with the low airflow speed regardless of the setting.

Healthy Dehumidification Mode


When the dehumidification operation input by the remote control is received, the intake air temperature is
detected and the setting temp is automatically set according to the intake air temperature.
26C Intake Air Temp
25C
24C Intake Intake Air Temp<26C
Intake Air Temp-1C
18C Intake Intake Air Temp<24C
Intake Air Temp-0.5C
Intake Air Temp<18C
18C

-15-

While in compressor off, the indoor fan repeats low airflow speed and pause.
While the intake air temp is between compressor on temp. and compressor off temp., 10-min dehumidification operation and 4-min compressor off repeat.
Compressor ON Temp.
Setting Temp+0.5C
Compressor OFF Temp. Setting Temp-0.5C
In 10-min dehumidification operation, the indoor fan operates with the low airflow speed.

Heating Mode Operation


When the intake air temp reaches +3above the setting temp, the compressor is turned off. When below
the setting temp, the compressor is turned on.
Compressor ON Temp.
Setting Temp.
Compressor OFF Temp. Setting Temp.+3C
While in compressor on, the indoor fan is off when the indoor pipe temp. is below 20C, when above 28C , it
operates with the low or setting airflow speed. When the indoor pipe temp is between 20C and 28C, it operates with Super-Low(while in sleep mode, with the medium airflow speed).
While in compressor off, the indoor fan is off when the indoor pipe temp is below 33C, when above 35C , it
operates with the low airflow speed.
If overloaded while in heating mode operation, in order to prevent the compressor from OLP operation, the
outdoor fan is turned on/off according to the indoor pipe temp.
While in defrost control, both of the indoor and outdoor fans are turned off.

Defrost Control
While in heating mode operation in order to protect the evaporator pipe of the outdoor unit from freezing,
reversed to cooling cycle to defrost the evaporator pipe of the outdoor unit.
After 40 min heating mode operation, at 4 min interval, whether to carry out defrost control or not and the time
of defrost control are determined according to the following conditions.
1) While in heating mode operation, the maximum of the indoor pipe temperature is measured and it is compared with the present indoor pipe temperature to get the difference of the indoor pipe temperatures (=the
maximum temperature of indoor pipe ? the present temperature of indoor pipe), according to which, whether
to carry out defrost control or not is determined.
2) According to the need of defrost control shown above and the elapsed time of heating mode operation at that
moment, the defrost control time is determined.
3) When the determined time of defrost control is below 7 min, heating mode operation continues without carrying out defrost control. According to the procedure stated above, the determination is made again. When the
defrost control time is 7 min or longer, defrost control is then carried out.
While in defrost control, the minimum temp of the indoor pipe is measured and it is compared with the present
temp of the indoor pipe to get the difference of the indoor pipe temperatures (=the present temperature of the
indoor pipe ? the minimum temperature of the indoor pipe). When the difference is 5C or higher, defrost control is completed and heating mode operation is carried out.
While in defrost control, if the defrost time determined before the start of defrost control is completed, defrost
control stops and heating mode operation is carried out regardless of the above condition.
When the indoor pipe temp is 42C or above, defrost control is not carried out even if the condition is one of
the defrost conditions above.
While in defrost control, the compressor is on and the indoor fan, the outdoor fan, and the 4 way valve are off.

-16-

Fuzzy Operation (C/O Model)


According to the temperature set by Fuzzy rule, when the intake air temp is 0.5C or more below the setting
temp, the compressor is turned off. When 0.5C or more above the setting temp, the compressor is turned on.
Compressor ON Temp
Setting Temp + 0.5C
Compressor OFF Temp
Setting Temp + 0.5C
At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temp at that time.
26C Intake Air Temp
25C
24C Intake Air Temp < 26C
Intake Air Temp + 1C
22C Intake Air Temp < 24C
Intake Air Temp + 0.5C
18C Intake Air Temp < 22C
Intake Air Temp
Intake Air Temp<18C
18C
When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature
automatically according to the Fuzzy rule.
While in Fuzzy operation, the airflow speed of the indoor fan is automatically selected according to the
temperature.

Fuzzy Operation (H/P Model)


When any of operation mode is not selected like the moment of the power on or when 3 hrs has passed since
the operation off, the operation mode is selected.
When determining the operation mode, the compressor, the outdoor fan, and the 4 way valve are off and only
the indoor fan is operated for 15 seconds. Then an operation mode is selected according to the intake air
temp at that moment as follows.
24C Inatake Air Temp
Fuzzy Operation for Cooling
21C Inatake Air Temp<24C
Fuzzy Operation for Dehumidification
Inatake Air Temp<21C
Fuzzy Operation for Heating
If any of the operation modes among cooling / dehumidification / heating mode operations is carried out for 10
sec or longer before Fuzzy operation, the mode before Fuzzy operation is operated.
1) Fuzzy Operation for Cooling
According to the setting temperature selected by Fuzzy rule, when the intake air temp is 0.5C or more below
the setting temp, the compressor is turned off. When 0.5C or more above the setting temp, the compressor
is turned on.
Compressor ON Temp
Setting Temp +0.5C
Compressor OFF Temp
Setting Temp + 0.5C
At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temp at that time.
26C Intake Air Temp
25C
24C Intake Air Temp<26C
Intake Air Temp + 1C
22C Intake Air Temp<24C
Intake Air Temp + 0.5C
18C Intake Air Temp<22C
Intake Air Temp
Intake Air Temp<18C
18C
When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature
automatically according to the Fuzzy rule.
While in Fuzzy operation, the airflow speed of the indoor fan is automatically selected according to the temperature.
-17-

2) Fuzzy Operation for Dehumidification


According to the setting temperature selected by Fuzzy rule, when the intake air temp is 0.5C or more below
the setting temp, the compressor is turned off. When 0.5C or more above the setting temp, the compressor
is turned on.
Compressor ON Temp
Setting Temp + 0.5C
Compressor OFF Temp
Setting Temp+0.5C
At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temp at that time.
26C Intake Air Temp
25C
24C Intake Air Temp<26C
Intake Air Temp+1C
22C Intake Air Temp<24C
Intake Air Temp+0.5C
18C Intake Air Temp<22C
Intake Air Temp
Intake Air Temp<18C
18C
When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature
automatically according to the Fuzzy rule.
While in Fuzzy operation, the airflow speed of the indoor fan repeats the low airflow speed or pause as in
dehumidification operation.
3) Fuzzy Operation for Heating
According to the setting temperature selected by Fuzzy rule, when the intake air temp is 3C or more above
the setting temp, the compressor is turned off. When below the setting temp, the compressor is turned on.
Compressor ON Temp
Setting Temp
Compressor OFF Temp
Setting Temp + 3C
At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temp at that time.
20CIntake Air Temp
Intake Air Temp + 0.5C
Intake Air Temp<20C
20C
When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature
automatically according to the Fuzzy rule.
While in Fuzzy operation, the airflow speed of the indoor fan is set to the high or the medium according to the
intake air temperature and the setting temperature.

Airflow Speed Selection


The airflow speed of the indoor fan is set to high, medium, low, or chaos (auto) by the input of the airflow
speed selection key on the remote control.

On-Timer Operation
When the set time is reached after the time is input by the remote control, the appliance starts to operate.
The timer LED is on when the on-timer is input. It is off when the time set by the timer is reached.
If the appliance is operating at the time set by the timer, the operation continues.

-18-

Off-Timer Operation
When the set time is reached after the time is input by the remote control, the appliance stops operating.
The timer LED is on when the off-timer is input. It is off when the time set by the timer is reached.
If the appliance is on pause at the time set by the timer, the pause continues.

Off-Timer On-Timer Operation


When the set time is reached after the on/off time is input by the remote control, the on/off-timer operation is
carried out according to the set time.

Sleep Timer Operation


When the sleep time is reached after <1,2,3,4,5,6,7,0(cancel) hr> is input by the remote control while in appliance operation, the operation of the appliance stops.
While the appliance is on pause, the sleep timer mode cannot be input.
While in cooling mode operation, 30 min later since the start of the sleep timer, the setting temperature
increases by 1C. After another 30 min elapse, it increases by 1C again.
When the sleep timer mode is input while in cooling cycle mode, the airflow speed of the indoor fan is set to the
low.
When the sleep timer mode is input while in heating cycle mode, the airflow speed of the indoor fan is set to
the medium.

Chaos Swing Mode


By the Chaos Swing key input, the upper/lower vane automatically operates with the Chaos Swing or they are
fixed to the desired direction.
While in Chaos Swing mode, the angles of cooling and heating cycle operations are different.

< Cooling Mode >

< Heating Mode >

CLOSED

CLOSED

OPEN

OPEN

Chaos Natural Wind Mode


When the Chaos Natural Wind mode is selected and then operated, the high, medium, or low speed of the airflow mode is operated for 2~15 sec. randomly by the Chaos Simulation.

-19-

Jet Cool Mode Operation (C/O Model)


If the Jet Cool key is input at any operation mode while in appliance operation, the Jet Cool mode operates.
In the Jet Cool mode, the indoor fan is operated at super-high speed for 30 min at cooling mode operation.
In the Jet Cool mode operation, the room temperature is controlled to the setting temperature, 18C
When the sleep timer mode is input while in the Jet Cool mode operation, the Jet Cool mode has the priority.
When the Jet Cool key is input, the upper/lower vanes are reset to those of the initial cooling mode and then
operated in order that the air outflow could reach further.

Jet Cool Mode Operation (H/P Model)


While in heating mode or Fuzzy operation, the Jet Cool key cannot be input. When it is input while in the other
mode operation (cooling, dehumidification, ventilation), the Jet Cool mode is operated.
In the Jet Cool mode, the indoor fan is operated at super-high speed for 30 min at cooling mode operation.
In the Jet Cool mode operation, the room temperature is controlled to the setting temperature, 18C.
When the sleep timer mode is input while in the Jet Cool mode operation, the Jet Cool mode has the priority.
When the Jet Cool key is input, the upper/lower vanes are reset to those of the initial cooling mode and then
operated in order that the air outflow could reach further.

Forced Operation
Operation procedures when the remote control can't be used.
The operation will be started if the power button is pressed.
If you want to stop operation, re-press the button.
Cooling Model
Operating mode
Indoor FAN Speed
Setting Temperature

Cooling
High
22C

Heat pump Model


Room Temp. 24C 21C Room Temp. < 24C Room Temp. < 21C
Cooling
High
22C

Healthy Dehumidification
High
23C

Heating
High
24C

While in forced operation, the key input by the remote control has no effect and the buzzer sounds 10 times to
indicate the forced operation.

Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature and resets in 181 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller sets.
If you want to use this operation, open the front panel upward and Press the power button let it be pressed for
about 3 seconds.
If you want to stop the operation, re-press the button.

Auto restart
In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate
procedures automatically to the previous operating conditions.

Air Cleaner Operation


When an air cleaner function is selected during Air Conditioner operation
- Plasma air cleaner function will be operated while in any operation mode with selecting the function.
- The function is to be stopped while it is operating with selecting the function.
When an air cleaner function is selected during operation off
- The function will be only operated.
When inlet grille of air conditioner is opened during plasma operation, High Voltage Generator(H.V.B) is to be
stopped. When inlet grille of air conditioner is closed during plasma operation, High Voltage Generator(H.V.B)
will be operated again.
-20-

Remote Control Operation Mode


When the remote control is selected by the slide switch on the main unit, the appliance operates according to
the input by the remote control.

Protection of the evaporator pipe from frosting


If the indoor pipe temp is below 0C in 7 min. after the compressor operates without any pause while in cooling cycle operation mode, the compressor and the outdoor fan are turned off in order to protect the indoor
evaporator pipe from frosting.
When the indoor pipe temp is 7C or higher after 3 min. pause of the compressor, the compressor and the
outdoor fan is turned on according to the condition of the room temperature.

Buzzer Sounding Operation


When the appliance-operation key is input by the remote control, the short "beep-beep-" sounds.
When the appliance-pause key is input by the remote control, the long "beep" sounds.
When a key is input by the remote control while the slide switch on the main unit of the appliance is on the
forced operation position, the error sound "beep-beep-beep-beep-beep-" is made 10 times to indicate that the
remote control signal cannot be received.

-21-

Display Function
1. Heating Model

2. Cooling Model
Operation Indicator

Operation Indicator
Cooling, Soft Dry, Fan, Heating

Cooling, Soft Dry, Fan

Sleep Timer Indicator

Sleep Timer Indicator

Sleep Mode

Sleep Mode

Timer Indicator

Timer Indicator
Timer Mode

Timer Mode
Compressor Indicator

Defrost Indicator

OUTDOOR

Hot-start, Defrost
PLASMA Indicator

PLASMA Indicator

PLASMA

PLASMA Mode

PLASMA

PLASMA Mode

Self-diagnosis Function
Error
Code

Error Display LED


(Indoor body operation LED)

Error contents
Indoor room temperature
thermistor open/short
Indoor pipe temperature
thermistor open/short.

(once)
3sec

3sec

3sec

-22-

SVC check point

Indoor Thermistor
assembly check

Installation
1. Installation of indoor, Outdoor unit
1) Selection of the best location

Select a place so that the warm air and noise from the
air conditioner do not disturb neighbors.

1. Indoor unit

More than 10 cm

Do not have any heat or steam near the unit.


Select a place where there are no obstacles in front of
the unit.
Make sure that condensation drainage can be conveniently routed away.
Do not install near a doorway.
Ensure that the space around the left and right of the
unit is more than "A". The unit should be installed as
high on the wall as possible, allowing a minimum of
"B" from ceiling.
Use a stud finder to locate studs to prevent unnecessary damage to the wall.

More than 10 cm

More than 70 cm

2) Piping length and elevation

More than "B"

7k~14k

More than "A"


18k~28k

30k~38k

Max. Additional
Standard Max.
Length Elevation Length Refrigerant
A (m)
(g/m)
(m)
B (m)

Pipe Size

Capacity
(Btu/h)

GAS

LIQUID

3/8"(9.52)

1/4"(6.35)

4 or 7.5

15

1/2"(12.7)

1/4"(6.35)

4 or 7.5

15

20

1/2"(12.7)

1/4"(6.35)

4 or 7.5

15

30

20

5/8"(15.88)

1/4"(6.35)

4 or 7.5

15

30

20

5/8"(15.88)

3/8"(9.52)

4 or 7.5

15

30

30

5/8"(15.88)

3/8"(9.52)

7.5

15

30

30

3/4"(19.05)

3/8"(9.52)

7.5

15

30

50

Indoor unit

Outdoor unit

More than 2.3m

More than "B"


Indoor unit

Install the indoor unit on the wall where the height


from the floors more than 2.3 meters.
Grade
7K~28K
30K~38K

Clearance(cm)
A
10
30

CAUTION

20

B
5
12

Outdoor unit

Outdoor unit

Oil trap

2. Outdoor unit
If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation
from the condenser is not restricted.
Ensure that the space around the back and sides is
more than 10cm. The front of the unit should have
more than 70cm of space.
Do not place animals and plants in the path of the
warm air.
Take the air conditioner weight into account and select
a place where noise and vibration are minimum.

Indoor unit

If case more than 5m


CAUTION

Capacity is based on standard length and maximum


allowance length is on the basis of reliability.
Oil trap should be installed every 5~7 meters.
-23-

3) How to fix installation plate

4) Drill a hole in the wall

The wall you select should be strong and solid enough


to prevent vibration

Drill the piping hole with a 70mm hole core drill. Drill
the piping hole at either the right or the left with the
hole slightly slanted to the outdoor side.

1. Mount the installation plate on the wall with four


type A screws. If mounting the unit on a concrete
wall, use anchor bolts.
Mount the installation plate horizontally by aligning
the centerline using a level.

WALL
Outdoor

5-7mm

Installation Plate

Type "A" screw

2. Measure the wall and mark the centerline. It is


also important to use caution concerning the
location of the installation plate-routing of the
wiring to power outlets is through the walls typically. Drilling the hole through the wall for piping
connections must be done safely.

C
B

Installation plate
A

70mm

Left rear piping

70mm

Right rear piping

Distance (mm)

CHASSIS
(Grade)

A
90
45
75
0
105

SJ
SL, SK
SQ
SR
ST

B
20
40
12
40
0

C
80
80
80
20
210

D
20
20
12
40
0

Installation plate
C

Right rear piping

Left rear piping

CHASSIS
(Grade)
SM
SN

70mm

Distance (mm)
A
180
180

B
115
115

C
195

D
115
115

E
50
-

-24-

(3/16"~5/16")

Indoor

2. Flaring Work and Connection of Piping


1) Flaring work

4. Flaring work
Firmly hold copper pipe in a die in the dimension
shown in the table above.

1. Cut the pipes and the cable.


Use the piping kit accessory or pipes purchased locally.
Measure the distance between the indoor and the
outdoor unit.
Cut the pipes a little longer than the measured
distance.
Cut the cable 1.5m longer than the pipe length.

Copper
pipe

Bar

Bar
Yoke
Cone

Copper pipe
Clamp handle

Red arrow mark

Carry out flaring work using flaring tool as shown


below.

Slanted Uneven Rough

90

Handle

"A"

Main cause for refrigerant leakage is due to defect in


the flaring work. Carry out correct flaring work using the
following procedure.

Outside diameter
mm
inch
6.35
1/4
9.52
3/8
12.7
1/2
15.88
5/8
19.05
3/4

2. Burr removal
Completely remove all burrs from the cut cross section of pipe/tube.
Put the end of the copper tube/pipe in a downward
direction as you remove burrs in order to avoid dropping burrs into the tubing.

mm
0~0.5
0~0.5
0~0.5
0~1.0
1.0~1.3

5. Check
Compare the flared work with figure below.
If flare is noted to be defective, cut off the flared section and re-flare it.

Pipe
Reamer

Smooth all round


Inside is shiny without scratches

Point down

= Improper flaring =

3. Putting nut on
Remove flare nuts attached to indoor and outdoor
unit, then put them on pipe/tube having completed
burr removal.
(not possible to put them on after flaring work)

Even length
all round

Flare nut

Copper tube

-25-

Inclined Surface Cracked Uneven


damaged
thickness

2) Connection of piping Indoor

3. Tape the tubing, drain hose, and the connecting


cable. Be sure that the drain hose is located at the
lowest side of the bundle. Locating at the upper
side can cause drain pan to overflow inside the
unit.

Preparing the indoor unit's piping and drain hose for


installation through the wall.
Remove the plastic tubing retainer(see illustration
below) and pull the tubing and drain hose away from
chassis.
Replace the plastic tubing holder in the original position.

Loop
Connecting
cable

Gas side
piping

Drain hose

Liquid side
piping

Tubing holder

CAUTION
When install, make sure
that the remaining parts
must be removed clearly
so as not to damage the
piping and drain hose,
especially power cord
and connecting cable.

NOTE: If the drain hose is routed inside the room,


insulate the hose with an insulation material* so that
dripping from "sweating"(condensation) will not damage
furniture or floors.
*Foamed polyethylene or equivalent is recommended.
4. Indoor unit installation
Hook the indoor unit onto the upper portion of the
installation plate.(Engage the two hooks of the rear
top of the indoor unit with the upper edge of the installation plate.) Ensure that the hooks are properly seated on the installation plate by moving it left and right.

For right rear piping


1. Route the indoor tubing and the drain hose in the
direction of rear right.

Connecting
cable

Drain hose

Press the lower left and right sides of the unit against
the installation plate until the hooks engage into their
slots(clicking sound).
4. Connecting the pipings to the indoor unit and drain
hose to drain pipe.
Align the center of the pipes and sufficiently tighten
the flare nut by hand.

Drain hose

2. Insert the connecting cable into the indoor unit


from the outdoor unit through the piping hole.
Do not connect the cable to the indoor unit.
Make a small loop with the cable for easy
connection later.

Indoor unit tubing

-26-

Flare nut

Pipes

Wrap the area which accommodates the rear piping


housing section with vinyl tape.

Tighten the flare nut with a wrench.

Open-end wrench (fixed)


Flare nut

Vinyl tape
(wide)

Connection pipe

Wrench

Indoor
unit pipe

Connection
pipe
Wrap with vinyl tape

Connecting cable

Indoor unit tubing

Outside diameter
mm
inch
6.35
1/4
9.52
3/8
12.7
1/2
15.88
5/8
19.05
3/4

Torque
kg.m
1.8
4.2
5.5
6.6
6.6

Pipe
Vinyl tape(narrow)

Bundle the piping and drain hose together by wrapping them with vinyl tape for enough to cover where
they fit into the rear piping housing section.

When extending the drain hose at the indoor unit,


install the drain pipe.

Wrap with vinyl tape


Pipe

Drain pipe
Vinyl tape(wide)
Drain hose
Indoor unit drain hose
Adhesive

For left rear piping

Vinyl tape(narrow)

1. Route the indoor tubing and the drain hose to the


required piping hole position.

5. Wrap the insulation material around the connecting


portion.
Overlap the connection pipe insulation material and
the indoor unit pipe insulation material. Bind them
together with vinyl tape so that there is no gap.
Plastic bands Insulation material

2. Insert the piping, drain hose, and the connecting


cable into the piping hole.

Connecting cable
Drain pipe

-27-

3. Insert the connecting cable into the indoor unit.


Don't connect the cable to the indoor unit.
Make a small loop with the cable for easy connection
later.

Outside diameter
mm
inch
6.35
1/4
9.52
3/8
12.7
1/2
15.88
5/8
19.05
3/4

4. Tape the drain hose and the connecting cable.


Connecting cable

Torque
kg.m
1.8
4.2
5.5
6.6
6.6

When extending the drain hose at the indoor unit,


install the drain pipe.

Drain hose

Indoor unit drain hose

5. Indoor unit installation


Hang the indoor unit from the hooks at the top of the
installation plate.
Insert the spacer etc. between the indoor unit and the
installation plate and separate the bottom of the
indoor unit from the wall.

Adhesive

Vinyl tape (narrow)

7. Wrap the insulation material around the connecting portion.


Overlap the connection pipe heat insulation and the
indoor unit pipe heat insulation material. Bind them
together with vinyl tape so that there is no gap.

Indoor unit
Spacer

Plastic bands Insulation material

Installation plate
8cm

6. Connecting the pipings to the indoor unit and the


drain hose to drain pipe.
Align the center of the pipes and sufficiently tighten
the flare nut by hand.

Wrap the area which accommodates the rear piping


housing section with vinyl tape.
Indoor
unit piping

Connection
pipe
Indoor unit tubing

Flare nut

Vinyl tape
(wide)

Pipes

Wrap with vinyl tape

Tighten the flare nut with a wrench.


Pipe
Open-end wrench (fixed)
Vinyl tape(narrow)
Connecting cable

Flare nut
Wrench

Connection pipe

Indoor unit tubing

-28-

3) Connection of the pipes-Outdoor

Bundle the piping and drain hose together by wrapping them with cloth tape over the range within which
they fit into the rear piping housing section.

1. Align the center of the pipings and sufficiently


tighten the flare nut by hand.

Pipe
Drain hose
Vinyl tape(narrow)

Wrap with
vinyl tape(wide)

8. Reroute the pipings and the drain hose across the


back of the chassis.

2. Finally, tighten the flare nut with torque wrench


until the wrench clicks.
When tightening the flare nut with torque wrench,
ensure the direction for tightening follows the arrow on
the wrench.
Outside diameter
mm
inch
6.35
1/4
9.52
3/8
12.7
1/2
15.88
5/8
19.05
3/4

Piping for
passage through
piping hole

9. Set the pipings and the drain hose to the back of


the chassis with the tubing holder.
Hook the edge of tubing holder to tap on chassis and
push the bottom of tubing holder to be engaged at the
bottom of chassis.

Torque
kg.m
1.8
4.2
5.5
6.6
6.6

Outdoor unit
Gas side piping
(Bigger diameter)

Liquid side
piping
(Smaller
diameter)

Tubing holder

Torque wrench

10. Indoor unit installation


Remove the spacer.
Ensure that the hooks are properly seated on the
installation plate by moving it left and right.

LS-Q096ABL

Outdoor unit

Gas side piping


(Bigger Dia.)

Connecting
cable
Liquid side piping
(Smaller Dia.)

Drain hose

Torque wrench

Press the lower left and right sides of the unit against
the installation plate until the hooks engage into their
slots(clicking sound).
LS-Q096AAL

-29-

3. Connecting The Cable Between Indoor Unit and Outdoor Unit


1) Connect the cable to the Indoor unit.
Connect the cable to the indoor unit by connecting the wires to the terminals on the control board in
dividually according to the outdoor unit connection. (Ensure that the color of the wires of the outdoor unit and
the terminal No. are the same as those of the indoor unit.)
The earth wire should be longer than the common wires.

CAUTION
When installing, refer to the circuit diagram on the
Control Box of Indoor Unit.
When installing, refer to the wiring diagram on the
Control Cover Inside Outdoor Unit.

The power cord connected to the "A" unit should be


complied with the following specifications
(Type "B" approved by HAR or SAA).

CAUTION
(mm2)

The above circuit diagram is subject to change without notice.


Be sure to connect wires according to the wiring diagram.
Connect the wires firmly, so that not to be pulled out
easily.
Connect the wires according to color codes by referring the wiring diagram.

NORMAL
CROSS
5k~9K
-SECTIONAL
0.75
AREA
Unit(A)

Indoor

Grade
12k~14k

18k

24k~28k 30k, 32k 36k, 38k

1.0

1.5

2.5

Indoor

Indoor

Indoor

2.5

5.5

Outdoor Outdoor

Cable Type(B) H05VV-F H05VV-F H05VV-F H05VV-F H05RN-F H05RN-F

The power connecting cable connected to the indoor


and outdoor unit should be complied with the following
specifications
(Type "B" approved by HAR or SAA).

CAUTION
If a power plug is not to be used, provide a circuit breaker
between power source and the unit as shown below.
Main power source
(mm2)

Air
Conditioner

NORMAL
Grade
CROSS
5k~9k 12k~14k 18k
-SECTIONAL
0.75
1.0
1.5
AREA

Circuit Breaker
Use a circuit
breaker or time
delay fuse.

24k~28k
2.5

Cable Type(B) H07RN-F H07RN-F H07RN-F H07RN-F

(mm2)
Grade
NORMAL CROSS
30k, 32k 36k, 38k
-SECTIONAL AREA
0.75
0.75
Cable Type(B) H07RN-F H07RN-F

-30-

NORMAL
CROSS-SECTIONAL
AREA 0.75mm2

2) Connect the cable to the outdoor unit

Outdoor unit
Terminal block
(Pillar terminal)

1. Remove the control cover from the unit by loosening the screw.
Connect the wires to the terminals on the control
board individually.

Connecting
cable
Holder for
connecting
cable

Over
5mm

2. Secure the cable onto the control board with the


cord clamp.

Cover control

3. Refix the control cover to the original position


with the screw.

LS-Q096AAL

4. Use a recognized circuit breaker "A"


between the power source and the unit.
A disconnecting device to adequately disconnect
all supply lines must be fitted.
Circuit
Breaker
(A)

Outdoor unit
Terminal block
(Pillar terminal)

Grade
7k~14k

18k

15

20

24k~28k 30k, 32k 36k, 38k


30

30

Over 5mm

Holder for
power supply
cord
Cover control

40

Connecting cable

LS-Q096ABL

CAUTION
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have an individual power circuit specifically for the air conditioner. As for the method of
wiring, be guided by the circuit diagram posted on the inside of control cover.
2) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from
vibrations to which the unit is subjected during the course of transportation. Check them and make
sure that they are all tightly fastened. (If they are loose, it could cause burn-out of the wires.)
3) Specification of power source.
4) Confirm that electrical capacity is sufficient.
5) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked on
the name plate.
6) Confirm that the cable thickness is as specified in the power source specification.
(Particularly note the relation between cable length and thickness. (Refer to page 30))
7) Always install an earth leakage circuit breaker in a wet or moist area.
8) The following would be caused by voltage drop.
Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the normal
function of the overload.
9) The means for disconnection from a power supply shall be incorporated in the fixed wiring and have an
air gap contact separation of at least 3mm in each active(phase) conductors.

-31-

4. Checking the Drainage and Forming the Pipings


1) Checking the drainage

2) Form the piping

1. To remove the front panel from the indoor unit.


Set the air direction louvers up-and-down to the position(horizontally) by hand.
Remove the securing screws that retain the front panel. Pull the lower left and right sides of the grille
toward you and lift it off.

1. Form the piping by wrapping the connecting portion of the indoor unit with insulation material and
secure it with two kinds of vinyl tapes.
If you want to connect an additional drain hose, the
end of the drain outlet should be routed above the
ground. Secure the drain hose appropriately.
2. In cases where the outdoor unit is installed below
the indoor unit perform the following.
Tape the piping, drain hose and connecting cable from
down to up.
Secure the tapped piping along the exterior wall using
saddle or equivalent.

Pull the right and


the left side.

Seal small openings


around pipings with a
gum type sealer.

2. To check the drainage.


Pour a glass of water on the evaporator.
Ensure the water flows through the drain hose of the
indoor unit without any leakage and goes out the drain
exit.

Taping
Drain
hose

Pipings

Taping
Drain hose

Connecting
cable

Pipings
Connecting
cable

LS-Q096AAL

LS-Q096ABL

Trap is required to prevent water


from entering into electrical parts.

3. In cases where the Outdoor unit is installed above


the Indoor unit perform the following.
Tape the piping and connecting cable from down to up.
Secure the taped piping along the exterior wall. Form
a trap to prevent water entering the room.
Fix the piping onto the wall by saddle or equivalent.

3. Drain piping
The drain hose should point downward for easy drain
flow.

Seal a small opening


around the pipings
with gum type sealer.

Downward slope

Trap

Do not make drain piping.


Accumulated
drain water
Air

Do not raise

Water
leakage

Water
leakage

Waving

Tip of drain hose


dipped in water
Water
leakage

Less than
50mm gap

Trap

Ditch

-32-

5. Test Running
1. Check that all tubing and wiring have been properly
connected.
2. Check that the gas and liquid side service valves are
fully open.

Intake temperature
Discharge air

1. Prepare remote control


1. Remove the battery cover
by pulling it according to the
arrow direction.
2. Insert new batteries making
sure that the (+) and () of
battery are installed correctly.
3. Reattach the cover by
pushing it back into position.

Discharge
temperature

4. For reference; the gas side pressure of optimum condition is as below.(Cooling)

NOTE:
Use 2 AAA(1.5volt) batteries. Do not use rechargeable batteries.
Remove the batteries from the remote control if the
system is not going to be used for a long time.

Refrigerant

Outside ambient
TEMP.

The pressure of the gas side


service valve.

R-22

35C (95F)

4~5kg/cm2G(56.8~71.0 P.S.I.G.)

NOTE: If the actual pressure is higher than shown, the


system is most likely over-charged, and charge
should be removed. If the actual pressure are
lower than shown, the system is most likely
undercharged, and charge should be added.
The air conditioner is now ready for use.

2. Settlement of outdoor unit


Anchor the outdoor unit with a bolt and nut(10mm)
tightly and horizontally on a concrete or rigid mount.
When installing on the wall, roof or rooftop, anchor the
mounting base securely with a nail or wire assuming
the influence of wind and earthquake.
In the case when the vibration of the unit is conveyed
to the hose, secure the unit with an anti-vibration
bushing.

PUMP DOWN
This is performed when the unit is to be relocated
or the refrigerant circuit is serviced.
Pump Down means collecting all refrigerant in the
outdoor unit without loss in refrigerant gas.
CAUTION:
Be sure to perform Pump Down procedure with the
unit cooling mode.

Bolt

Pump Down Procedure


1. Connect a low-pressure gauge manifold hose to
the charge port on the gas side service valve.
2. Open the gas side service valve halfway and purge
the air from the manifold hose using the refrigerant
gas.
3. Close the liquid side service valve(all the way in).
4. Turn on the unit's operating switch and start the
cooling operation.
5. When the low-pressure gauge reading becomes 1
to 0.5kg/cm2 G(14.2 to 7.1 P.S.I.G.), fully close the
gas side valve stem and then quickly turn off the
unit. At that time, Pump Down has been completed
and all refrigerant gas will have been collected in
the outdoor unit.

Tubing connection

3. Evaluation of the performance


Operate unit for 15~20 minutes, then check the system
refrigerant charge:
1. Measure the pressure of the gas side service valve.
2. Measure the temperature of the intake and discharge
of air.
3. Ensure the difference between the intake temperature and the discharge is more than 8C(46F) (Cooling) or (Heating).
-33-

Operation
Name and Function-Remote Control
The remote control transmits the signals to the system.

START/STOP BUTTON
Operation starts when this button is pressed and stops
when the button is pressed again.

OPERATION MODE SELECTION BUTTON


Used to select the operation mode.

ROOM TEMPERATURE SETTING BUTTONS


Used to select the room temperature.

Remote Control

Signal transmitter

5
5

3
ON

JET COOL
Used to start or stop the speed
cooling. (Speed cooling operates
super high fan speed in cooling mode.)
CHAOS SWING BUTTON
Used to stop or start louver movement and set the
desired up/down airflow direction.

OFF

10

11
SET

INDOOR FAN SPEED SELECTOR


Used to select fan speed in four steps
low, medium, high and CHAOS.

ON/OFF TIMER BUTTONS


Used to set the time of starting and stopping operation.

TIME SETTING BUTTONS


Used to adjust the time.

CANCEL

12
PLASMA

13

15

14

Flip-up door
(opened)

10
11

Operation Mode

TIMER SET/CANCEL BUTTONS


Used to set the timer when the desired time is obtained
and to cancel the Timer operation.
SLEEP MODE AUTO BUTTON
Used to set Sleep Mode Auto operation.
AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or heating.

Cooling Operation

12

ROOM TEMPERATURE CHECKING BUTTON


Used to check the room temperature.

Auto Operation

13

PLASMA(OPTION)
Used to start or stop the plasma-purification function.

14

RESET BUTTON
Used prior to resetting time or after replacing batteries.

Healthy Dehumidification Operation


Heating Operation

Cooling Model(

), Heat Pump Model(

15

-34-

HORIZONTAL AIRFLOW DIRECTION CONTROL BUTTON (NOT ON ALL MODELS)


Used to set the desired horizontal airflow direction.

Name and Function-Remote Control


The remote control transmits the signals to the system.

START/STOP BUTTON
Operation starts when this button is pressed and stops
when the button is pressed again.

OPERATION MODE SELECTION BUTTON


Used to select the operation mode.

ROOM TEMPERATURE SETTING BUTTONS


Used to select the room temperature.

INDOOR FAN SPEED SELECTOR


Used to select fan speed in four steps low, medium, high
and CHAOS.

JET COOL
Used to start or stop the speed cooling. (Speed cooling
operates super high fan speed in cooling mode.)

CHAOS SWING BUTTON


Used to stop or start louver movement and set the desired
up/down airflow direction.

ON/OFF TIMER BUTTONS


Used to set the time of starting and stopping operation.

TIME SETTING BUTTONS


Used to adjust the time.

TIMER SET/CANCEL BUTTON


Used to set the timer when the desired time is obtained
and to cancel the Timer operation.

10

SLEEP MODE AUTO BUTTON


Used to set Sleep Mode Auto operation.

11

AIR CIRCULATION BUTTON


Used to circulate the room air without cooling or heating.

12

ROOM TEMPERATURE CHECKING BUTTON


Used to check the room temperature.

13

PLASMA(OPTIONAL)
Used to start or stop the plasma-purification function.

14

HORIZONTAL AIRFLOW DIRECTION CONTROL


BUTTON (NOT ON ALL MODELS)
Used to set the desired horizontal airflow direction.

15

RESET BUTTON
Used prior to resetting time or after replacing batteries.

16

2nd F Button
Used prior to using modes printed in blue at the bottom of
buttons.

Remote Control
Signal transmitter

6
3
4
2
7
11
8
13

10
CANCEL

9
ON

OFF

SET

12
14

15

16

Flip-up door
(opened)

Operation Mode
Cooling Operation
Auto Operation

Healthy Dehumidification Operation


Heating Operation

Cooling Model(

), Heat Pump Model(

-35-

Disassembly of the parts (Indoor unit)


Warning :
Disconnect the unit from power supply before making
any checks.
Be sure the power switch is set to OFF.

To remove the Grille from the Chassis.


Set the up-and-down air discharge louver to open
position (horizontally) by finger pressure.
Remove the securing screws.
To remove the Grille, pull the lower left and right
side of the grille toward you (slightly tilted) and lift it
straight upward.

Display
P.C.B
Conductor
1. Before removing the control box, be sure to
take out the wire screwed at the other end.

Sensor
Conductor
Motor
Conductor

Earth
Conductor

Earth
Conductor

-36-

Step Motor
Conductor

2. To remove the Control Box.


Remove securing screws.
Pull the control box out from the chassis carefully.
Caution label

3. To remove the Discharge Grille.


Unhook the discharge grille and pull the discharge grille out from the chassis carefully.

4. To remove the Evaporator.


Remove 3 screws securing the evaporator(at the
left 2EA in the Eva Holder, at the right 1EA).

Caution label
When repair, do not damage the Caution
label.

-37-

Unhook the tab on the right inside of the chassis


at the same time, slightly pull the evaporator
toward you until the tab is clear of the slot.

5. To remove the Motor Cover


Remove 2 securing screw.
Pull the motor cover out from the chassis
carefully.

Motor cover

6. To remove the Cross-Flow Fan


Loosen the screw securing the cross-flow fan to
the fan motor (do not remove).
Lift up the right side of the cross-flow fan and the
fan motor, separate the fan motor from the
cross-flow fan.

Remove the left end of the cross-flow fan from


the self-aligning bearing.

-38-

2-way, 3-way Valve


2-way Valve (Liquid Side)

Hexagonal wrench (4mm)


Flare nut

3-way Valve (Gas Side)

Valve cap
Open position
Flare nut
Closed position

Open position
Closed position
To
piping
connection

To
piping
connection

To outdoor unit

Works
Shipping

1.

Air purging
(Installation)

Operation

Pin

Service Service
port cap port

To outdoor unit

Shaft position

Shaft position

Service port

Closed
(with valve cap)

Closed
(with valve cap)

Closed
(with cap)

Open
(counter-clockwise)

Closed
(clockwise)

Open
(push-pin or with
vacumm pump)

Open
(with valve cap)

Open
(with valve cap)

Closed
(with cap)

Closed
(clockwise)

Open
(counter-clockwise)

Open
(connected manifold
gauge)

2.

Pumping down
(Transfering)
Evacuation
(Servicing)

Open

Open

3.

Open
(with charging
cylinder)

Gas charging
(Servicing)

Open

Open

4.

Open
(with charging
cylinder)

5.

Pressure check
(Servicing)

Open

Open

Open
(with charging cylinder)

6.

Gas releasing
(Servicing)

Open

Open

Open
(with charging cylinder)

-39-

1. Air purging
Required tools : hexagonal wrench, adjustable
wrench, torque wrenches, wrench to
hold the joints, and gas leak detector.

The air in the indoor unit and in the piping must be


purged. If air remains in the refrigeration pipes, it will
affect the compressor, reduce to cooling capacity, and
could lead to a malfunction.

The additional gas for air purging has been charged


in the outdoor unit.
However, if the flare connections have not be done
correctly and there gas leaks, a gas cylinder and the
charge set will be needed.
Indoor unit

Liquid side
Open

Outdoor unit

2-way
valve

Gas side
Clsed
3-way
valve

Service port nut:


Be sure, using a torque wrench to tighten the service port nut (after using the service port), so that it prevents the
gas leakage from the refrigeration cycle.
*
CAUTION : Do not leak the gas in the air during Air purging.

Procedure
(6) Set the 3-way valve to the back seat.

(1) Recheck the piping connections.

(7) Mount the valve stem nuts to the 2-way and 3way valves.

(2) Open the valve stem of the 2-way valve counterclockwise approximately 90, wait 10 seconds, and then set it to closed position.
Be sure to use a hexagonal wrench to operate
the valve stem.

(8) Check for gas leakage.


At this time, especially check for gas leakage
from the 2-way and 3-way valves stem nuts,
and from the service port nut.

(3) Check for gas leakage.


Check the flare connections for gas leakage.

Caution

(4) Purge the air from the system.


Set the 2-way valve to the open position and
remove the cap from the 3-way valves service
port.
Using the hexagonal wrench to press the valve
core pin, discharge for three seconds and then
wait for one minute. Repeat this three times.

If gas leakage are discovered in step (3) above,


take the following mesures :
If the gas leaks stop when the piping connections
are tightened further, continue working from step (4).
If the gas leaks do not stop when the connections
are retightened, repair the location of the leak, discharge all of the gas through the service port, and
then recharge with the specified amount of gas
from a gas cylinder.

(5) Use torque wrench to tighten the service port


nut to a torque of 1.8kg.cm.
-40-

2. Pumping down

Liquid side

Indoor unit

2-Way
valve

Open

Outdoor unit

Gas side

Closed
3-Way
valve

Lo
CLOSE

CLOSE

Purge the air

Procedure
(6) Operate the air conditioner at the cooling
cycle and stop it when the gauge indicates
1kg/cm2g.

(1) Confirm that both the 2-way and 3-way valves


are set to the open position.
Remove the valve stem caps and confirm that
the valve stems are in the raised position.
Be sure to use a hexagonal wrench to operate
the valve stems.

(7) Immediately set the 3-way valve to the closed


position.
Do this quickly so that the gauge ends up indicating 3 to 5kg/cm2g.

(2) Operate the unit for 10 to 15 minutes.

(8) Disconnect the charge set, and mount the 2way and 3-way valves stem nuts and the service port nut.
Use torque wrench to tighten the service port
nut to a torque of 1.8 kg.m.
Be sure to check for gas leakage.

(3) Stop operation and wait for 3 minutes, then


connect the charge set to the service port of
the 3-way valve.
Connect the charge hose with the push pin to
the service port.
(4) Air purging of the charge hose.
Open the low-pressure valve on the charge set
slightly to air purge from the charge hose.
(5) Set the 2-way valve to the closed position.

-41-

1) Re-air purging
(Re-installation)

Liquid side

Indoor unit

2-Way
valve

Closed

Outdoor unit

Gas side

Closed
3-Way
valve

Gas cylinder

Lo
R22

OPEN

CLOSE

Procedure
(6) Disconnect the charge set and the gas cylinder, and set the 2-way and 3-way valves to the
open position.
Be sure to use a hexagonal wrench to operate
the valve stems.

(1) Confirm that both the 2-way valve and the 3way valve are set to the closed position.
(2) Connect the charge set and a gas cylinder to
the service port of the 3-way valve.
Leave the valve on the gas cylinder closed.

(7) Mount the valve stem nuts and the service


port nut.
Use torque wrench to tighten the service port
nut to a torque of 1.8 kg.m.
Be sure to check for gas leakage.

(3) Air purging.


Open the valves on the gas cylinder and the
charge set. Purge the air by loosening the flare
nut on the 2-way valve approximately 45 for 3
seconds then closing it for 1 minute; repeat 3
times.
After purging the air, use a torque wrench to
tighten the flare nut on the 2-way valve.

(4) Check for gas leakage.


Check the flare connections for gas leakage.
(5) Discharge the refrigerant.
Close the valve on the gas cylinder and discharge the refrigerant until the gauge indicates
3 to 5 kg/cm2g.

-42-

CAUTION:
Do not leak the gas in the air during Air Purging.

2) Balance refrigerant of the 2-way, 3-way valves


(Gas leakage)

Liquid side

Indoor unit

Outdoor unit
2-Way
valve

Open

3-Way
valve

Open

Gas side

Lo
OPEN

CLOSE

Procedure

(3) Open the valve (Lo side) on the charge set


and discharge the refrigerant until the gauge
indicates 0 kg/cm2G.
If there is no air in the refrigerant cycle (the
pressure when the air conditioner is not running is higher than 1 kg/cm2G), discharge the
refrigerant until the gauge indicates 0.5 to 1
kg/cm2G. if this is the case, it will not be necessary to apply a evacuatin.
Discharge the refrigerant gradually; if it is discharged too suddenly, the refrigeration oil will
also be discharged.

(1) Confirm that both the 2-way and 3-way valves


are set to the back seat.
(2) Connect the charge set to the 3-way valves
port.
Leave the valve on the charge set closed.
Connect the charge hose with the push pin to
the service port.

-43-

3. Evacuation
(All amount of refrigerant leaked)

Liquid side

Indoor unit

Outdoor unit
2-Way
valve

Open

Gas side

3-Way
valve

Open

Vacuum pump
Lo
OPEN

CLOSE

Procedure

(4) Disconnect the charge hose from the vacuum


pump.
Vacuum pump oil.
If the vacuum pump oil becomes dir ty or
depleted, replenish as needed.

(1) Connect the vacuum pump to the charge sets


center hose
(2) Evacuation for approximately one hour.
Confirm that the gauge needle has moved
toward -76 cmHg (vacuum of 4 mmHg or less).
(3) Close the valve (Lo side) on the charge set,
turn off the vacuum pump, and confirm that
the gauge needle does not move (approximately 5 minutes after turning off the vacuum
pump).

-44-

4. Gas Charging
(After Evacuation)
Liquid side

Indoor unit

2-Way
valve

Open

Outdoor unit

Gas side

Open
3-Way
valve

Check valve

Charging
cylinder
Lo
(1)

OPEN

CLOSE

Procedure
\

(1) Connect the charge hose to the charging


cylinder.
Connect the charge hose which you dis-connected from the vacuum pump to the valve at
the bottom of the cylinder.
If you are using a gas cylinder, also use a scale
and revers the cylinder so that the system can
be charged with liquid.

This is different from previous procedures.


Because you are charging with liquid refrigerant
from the gas side, absolutely do not attempt to
charge with larger amounts of liquid refrigerant
while operating the air conditioner.
(4) Immediately disconnect the charge hose from
the 3-way valves service port.
Stopping partway will allow the gas to be discharged.
If the system has been charged with liquid
refrigerant while operating the air conditioner
turn off the air conditioner before disconnecting
the hose.

(2) Purge the air from the charge hose.


Open the valve at the bottom of the cylinder
and press the check valve on the charge set to
purge the air. (Be careful of the liquid refrigerant). The procedure is the same if using a gas
cylinder.
(3) Open the valve (Lo side on the charge set and
charge the system with liquid refrigerant.
If the system can not be charged with the specified amount of refrigerant, it can be charged
with a little at a time (approximately 150g each
time) while operating the air conditioner in the
cooling cycle; however, one time is not sufficient, wait approximately 1 minute and then
repeat the procedure (pumping down-pin).

(5) Mount the valve stem nuts and the service


port nut.
Use torque wrench to tighten the service port
nut to a torque of 1.8 kg.m.
Be sure to check for gas leakage.

-45-

Cycle Troubleshooting Guide


Trouble analysis
1. Check temperature difference between intake and discharge air and operating current.

Temp. Difference

Operating Current

Temp. difference
Current

: approx. 0C
: less than 80% of
rated current

All amount of refrigerant leaked


out. Check refrigeration cycle.

Temp. difference
Current

: approx. 8C
: less than 80% of
rated current

Refrigerant leakege
Clog of refrigeration cycle
Defective compressor

Temp. difference
Current

: less than 8C
: over the reated
current

Excessive amount of refrigerant

Temp. difference

: over 8C

Normal

Notice :
Temperature difference between intake and discharge air depends on room air humidity. When the room air
humidity is relativery higher, temperature difference is smaller. When the room air humidity is relatively lower temperature difference is larger.
2. Check temperature and pressure of refrigeration cycle.
Suction pressure
(Compared with
the normal value)

Temperature
(Compared with
the normal valve)

Cause of Trouble

High

Defective compressor
Defective 4-way reverse valve

Current is low.

Excessive amount of
refrigerant

High pressure does not quickly


rise at the beginning of
operation.

Insufficient amount of
refrigerant (Leakage)
Clogging

Current is low.

Higher
Normal

Lower

Higher

Description

Current is low.

Notice :
1. The suction pressure is usually 4.5~6.0 kg/cm2G(Cooling) at normal condition.
2. The temperature can be measured by attaching the thermometer to the low pressure tubing and wrap it with
putty.

-46-

Electronic Parts Troubleshooting Guide


1. Product does not operate at all.
(* Refer to Electronic Control Device drawing and Schematic diagram.)
Turn off Main Power
(After 10 seconds)
Turn on Main Power

Does "beeping" sound is made from the Indoor Unit?


YES

NO

Primarily, the operating condition of Micom is OK.

Check the voltage of power(About AC 220V, 60Hz)


(About AC 220/240V, 50Hz)
Main power's voltage
Voltage applied to the unit
Connecting method of Indoor/Outdoor connecting
cable
Check PWB Assembly
- Fuse
- Pattern damage
- Varistor(ZNR01J)

Check each load(Indoor/Outdoor Fan Motor, Compressor, Stepping Motor) and contacting
condition of related connector

Check the connection housing for contacting


Connector related to CN-TAB1, RY-COMP NO.3
Connector related to CN-MOTOR
Connector contacting of Outdoor Fan/Compressor
Display PWB Assembly Check

Main PCB Board Operation Check


Content

Items
SMPS Transformer
(Indoor unit)
- Input Voltage
- Output Voltage(ZD02D)

Remedy

- About AC220V/240V10% - Check the power voltage


- About DC12V

Replace Trans

IC04D(7805) Output
(Indoor/Outdoor unit)

DC +5V

Replace IC04D

IC01A(KIA7036, Reset IC)


X01(8MHz)

Voltage of Micom No. 2,


(DC +4.5V over) and Soldering condition.

Replace faulty parts

-47-

2. The product is not operate with the remote control.

Turn on Main Power

While the compressor has been stopped, the compressor does not
operate owing to the delaying function for 3 minutes after stopped.

When the compressor stopped Indoor Fan is driven by a low speed.


At this point the wind speed is not controlled by the remote controller.
(When operated in the Sleeping Mode, the wind speed is set to the
low speed by force.)

Caused by other parts except the remote control

Cause by the remote control

When the mark(


battery.

) is displayed in LCD screen, replace

Check the contact of CN-DISP1 connector.

Check the connecting circuit between the remote controller


MICOM (No. ) - R17(2) - IR LED - TR - R16(2.2K).

Check Display PWB Assembly


- Voltage between CN DISP1
-

: DC +5V

Check point
Check the connecting circuit between CN-DISP1
R01L(5.1K) - C01L(680pF) - MICOM PIN 43
Check Receiver Assembly

-48-

3. Compressor/Outdoor Fan are unable to drive.


Turn on Main Power

Operate "Cooling Mode( )" by setting the desired temperature of the


remote controller is less than one of the indoor temperature by 1C at least.

When in Air Circulation Mode, Compressor/Outdoor Fan is stopped.

Check the sensor for indoor temperature is attached as close as to be


effected by the temperature of Heat Exchanger(EVA).

When the sensor circuit for indoor temperature and connector are in bad
connection or are not engaged, Compressor/Outdoor Fan is stopped.
Check the related circuit of RY-FAN.
Check the indoor temperature sensor is disconnected or not(About 10k / at 25C).

Check Relay(RY - COMP) for driving compressor.


When the power(About AC220V/240V) is applied to the connecting wire
terminal support transferred to compressor, PWB Assembly is normal.
Check the circuit related to the relay.
Check point
Between Micom(No.
62) and GND
Between IC01M(No. 14)
and GND

COMP ON

COMP OFF

DC5V

DC0V

Below DC 1V
(app)

About DC12V

Turn off Main Power

Check the electrical wiring diagram of outdoor side.


Check the abnormal condition for the component of Compressor/Outdoor Fan Motor.
Check the "open" or "short" of conmecting wires between indoor and
outdoor.

-49-

4. When indoor Fan does not operate.


Turn off Main power

Check the connection of CN-MOTOR

Check the Fan Motor

Check the Fuse(AC250V/T2A)

Check the related circuit of indoor Fan Motor.


The pin NO 58 of Micom, and the part for driving TRIAC(the input and
output signal of IC01M, PIN NO 7, 10)
Check the pattern
Check the TRIAC
- TRIAC Open: Indoor Fan Motor never operate
- TRIAC short: Indoor Fan Motor always operates in case of ON or OFF.

Turn ON Main Power

Check the TRIAC high speed operation by remote control.


(The Indoor Fan Motor is connected)
The voltage of PIN NO 1(orange) and 3(yellow) of CN-MOTOR.

About AC 180V over

About AC 50V over

TRIAC is not damaged

TRIAC Check

-50-

5. When Vertical Louver does not operate.


Confirm that the Vertical Louver is normally geared with the shaft of
Stepping Motor.
If the regular torque is detected when rotating the Vertical Louver with
Normal
hands

Check the connecting condition of CN-U/D Connector


Check the soldering condition(on PWB) of CN-U/D Connector

Check the operating circuit of the Vertical Louver


Confirm that there is DC +12V between pin (RED) of CN-U/D and
GND.
Confirm that there is a soldering short at following terminals.
- Between 60 , 61 , 62 and 63 of MICOM
- Between , ,
and
of IC01M
- Between , ,
and
of IC01M

If there are no problems after above checks


Confirm the assembly conditions that are catching and interfering parts
in the rotation radial of the Vertical Louver

-51-

6. When Heating does not operate


Turn ON Main Power

Operate Heating Mode( ) by setting the desired temperature of the


remote control is higher than one of the indoor temperature by 2C at
least.

In heating Mode, the indoor fan operates in case the pipe temperature
is higher than 28C.

Check the connector of intake and pipe sensor(thermistors)


Check the related circuit of RY-4WAY
Check the indoor room temperature is disconnected or not (about
10K/at 25C).
Check the indoor pipe temperature is disconnected or not (about
5K/at 25C).

Check the DC voltage on the PWB ASSEMBLY


The details of check are as followings
Comp Relay.

Outdoor fan Relay

Check point

Comp ON

Comp OFF

Check point

Fan ON

Fan OFF

Between Micom
(NO.59) and GND

DC 5V

DC 0V

Between Micom
(NO.53) and GND

DC 5V

DC 0V

Between IC01M
Below DC 1V
(NO.11) and GND

Between IC02M
Below DC 1V About DC 12V
(NO.12) and GND

About DC
12V

4 way Relay
Check point

4 way ON

4 way OFF

Between Micom
(NO.51) and GND

DC 5V

DC 0V

Between IC02M
Below DC 1V About DC 12V
(NO.11) and GND

-52-

Turn off Main Power

Check the electrical wiring diagram of outdoor side.


Check the abnormal condition for the component of Compressor/Outdoor Fan Motor, 4 way.
Check the "open" or "short" of connecting wires between indoor and
outdoor.

-53-

Electronic Control Device


(1) MAIN P.W.B ASSEMBLY (AC PART)
TOP VIEW
BOTTOM VIEW

(1) MAIN P.W.B ASM (AC)


COOLING MODEL

HEAT PUMP MODEL

-54-

(2) MAIN P.W.B ASSEMBLY (DC PART)


TOP VIEW
BOTTOM VIEW

TOP VIEW

BOTTOM VIEW

-55-

TOP VIEW

BOTTOM VIEW

6871A20164
6871A20216
6871A20217
6871A20218
6871A20219
6871A20220

-56-

(3) DISPLAY ASSEMBLY


6871A20194
TOP VIEW

BOTTOM VIEW

6871A30009
TOP VIEW

BOTTOM VIEW

6871A20227
TOP VIEW

BOTTOM VIEW

-57-

6871A20390
TOP VIEW

BOTTOM VIEW

6871A20391
TOP VIEW
C01A

88SEG

BOTTOM VIEW
C01A

-58-

TELEPHONE-CONTROL MODEL ONLY

Schematic Diagram

-59-

Cooling Model
LED TYPE

-60-

Cooling Model
HVB TYPE(PLASMA)

-61-

RECEIVER

Vout

GND

Vcc

DISPLAY

R02G 220

R03G 220

R04G 220

Sleep

Timer

Defrost

LED2

LED3

LED4

C01A
104

R01G 220

Operation

LED1

S/W(FORCE)

HVB

STEPPING MOTOR
(UP/DOWN)

-621

RD

OR

YL

PK

BL

Option

2
1

1
12V

HVB OUT

receiver

AC PART

CN-12V

CN-CONT

CN-HVB

5V
C02L
220uF SD
10V

12V

HVB OUT

COMP

INDOOR FAN

CN-U/D

DC PART

5V

5V

20K 2012

R11H~R14H

5V

7
8

Vcc
WP
SCL

3 A1

+ C09D
220
10V SD

R11H

R12H

R13H

R14H

CAT24WC01J

EEPROM

SDA

2 A2

4 A0

1 G

IC01G
KID65004AF

IC01M
KID65004AF

C08D
103
25V

OJ1H

20K
R01P
2012

20K
R02F

OJ3H

5V

5V

IC04D
S78DL05L 1W
O
I
7805

OJ2H

20K
R02P
2012

5V

OJ4H

C04C
103

C07D
103
25V

12V

12
13
14
15
16

7
8
9
10
11

2
3
4
5
6

2
4

4
5

5
1

1
CN-L/R

1
2

3 4 5 6 7

16 15 14 13 12 11 10 9

BL PK YL OR RD

FAN
A
V
d
d
1
A
V
s
s

B
Z

AVref

AVdd

RESET

X2

X1

Vss1

INT0

INT1

ZD02D
BZX55C11

R02D
20K
1/6W

DC LOW
VOLTAGE GND

C06D
330
25V SD

L1
ZBF503D

33

36
35
34

38
37

42
41
40
39

44
43

47
46
45

48

C03C
103

5V

5V

5V

DC HIGH
VOLTAGE GND

C03D
681

C03T
102

R01T
1K

SMPS

C02D
104
50V

R21H

R26H

R25H

R24H

R23H

R22H

FAN

OSC01B
CSTS0800MG03-T2
CRTL8.00MSOT

4WAY

R01B
1M

RY-4WAY

INT

D07D
UG2D
C04D
470/35V/SD

12V

INT

+ C02C
220uF
10V/SD

IC02D
TLP421(V4 BL)

L2
10nH

OR6H OR5H OR4H OR3H OR2H OR1H


F2
F1
Hi Med
Low O/L

C05D
472M

4
1
2

R03D
39
1/6W

5V

CN-ACDC

CN-ACDC2

5V

17 18 1920 21 22 23 24 25 26 27 28 29 30 31 32

Vdd0

Vss0

NEC
UPD780023AGC-C

12V

IC02M
KID65004AF

64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49

STEPPING MOTOR
(LEFT/RIGHT)

4WAY

Option

12V

12V

12V

IC01D
TNY266P

SD01D
STO2D-200

12V

R05H
10K

DC HIGH
VOLTAGE GND

S 2

BP 1

EN 4

D 5

RY-FAN

C01A
0.01
50V

C01D
4.7uF
450V/SD

INT

C02T
102

DC LOW
VOLTAGE GND

IC03D
TLP421(V4 BL)

NTC SCK-102

INDOOR FAN

INDOOR FAN

5V

IC01A
KIA7036P
S7136

5V

INT

5V

receiver

5V

BZ01E
PKM13EPY-4002

Q01T
C104S

Q04T
A104S

3.6V

R02H
12.1K
1%

R06D
56K

R07D
12K

R02A,20K

R04H
6.2K
1%

R02L,1K

R01L 5.1K

R02E,20

C01L
680pF/50V

R01E
1K

Q02T
A104S

RY-COMP

COMP

5V

R21H~R26H
12.1K, 1%

Q01C
KTC3198-Y
2SC5343

5V

Q03T
C104S

5V

R04D
27k
1/6W

5V

D05D
1N4007

D01T
1N4148

5V

D08D
LL4148

R05D
300K
1/4W
3216

4
3

R06D
300K
1/4W

D01C
IN4007

3
2

2
1

D01A
IN4007

CN-TH

CN-TEL

DC HIGH
VOLTAGE GND

C01T
104

ROOM-TH

D01D
IN4007

D01B
IN4007

PIPE-TH

R04J
560
1/4W

C02J
METAL FILM
47nM/275V/435D

INDOOR FAN

12V

NF01J
15mH/1A

CN-TELE

CN-PHONE

D01T

Q03T

R01T

C06H

5V

C02T

TX

0.001uF
50V

R02J
100,1/2W

R03J
680
1/2W

1K

RY-HOOK

0.1uF/50V

C01J
METAL FILM
100nM/275V/436D

IC01J
TLP762JF

A104S

5V

1K

C104S

5V

A104S

Q01T

Q04T

0.001uF
50V

C01T

C104S

Q02T

10K

R15H

BSP351L

R12H

C02H

RX

5V

RST

270

R01A

50V

10uF

RY-FAN
G5N-1A(G5NB-1A)

RY-COMP

12V

C03J
METAL FILM
100nF/275V/436D

5V

13

11

3
2
1

5V

100K

R16H

C3198Y

R07H

2K

51K

OP1

C04H

RB3

RB2

RB1

RB0

VSS

MCLR

MICOM

VP

GS

VSS

NC

NC

X2

X1

VREF

RI

5V

10

11

12

13

14

15

100K

R01X

16

17

1M

R01B

5V

OSC01B

0.01uF
50V

C01X

CST-4.00MGW

RX

TX

SH-CAPACITOR

DE

Q0

Q1

Q2

Q3

DSO

0.1uF
50V

C02X

10 Q3

11 Q2

12 Q1

13 Q0

14

15

16

17

18

15

12

RY-COMP
G4A-1A-E-LG

RY-COMP

12V

CN-TAB1

TERMINAL BOARD

OE

D0

D1

D2

D3

DV

EST

RB4

RB5

RB6

RB7

VDD

OSC2

OSC1

RA0

RA1

PIC16C54CR

T0CLK

RA3

IC-DTMF
HT9170B

RA2

1uF
16V

1
2

(ST9170)
VN
18
VDD

DSO

DE

10K

OP2

10K

INDOOR
FAN
MOTOR

CST-3.58M

OSC02B

DE

BD

5V

R17H

R08H

100K

RST

5V

R01M
Q01M

4.7K

1N4004

D01M

27

R06H

KIA7036P

IC01A

C09H
1uF
63V

PC01H
TLP621BL

CN-MOTOR

3.6V

R01J
120, 1/2W

100

R03A

4.7K

27

R05H

2222A

KTC2016

Q02M

4.7K

R04H

Q03M

TRANS

R02A

5.1V, 1/2W

C01A +

1K

7.5K

R03H

T1

R02H
6.2K
1/4W

ZD02H~ZD03H

0.1uF
50V

ZD02H

22uF
50V

C03H

ZD03H C11H

R13H

1.5KE56A

ZD01H

ZNR02J
TVR10561

C08H
0.15uF
63V

750

R14H

1N4004

D01H~D04H

RY-4WAY
G5N-1A(G5NB-1A)

ZNR01J
TVR10561

FUSE
250V/T2A

0.1uF/50V

T2
TR01J
TRAICS
SM1L43
T1

LM358

OP-AMP

1K

6.2K/1W

R01H

1uF DC250V

C01H
ZD05H

HR93F,5V
G6A-234P,5V

ZD04H

ZNR01

R09H

0.01uF
100V

C05H

100uF/25V

C01D

1N4148

5V

BD

2.7 1/2W

R18H

2.7 1/2W

R19H

3.9V, 1/2W

ZD04H~ZD05H

TELE (OPTION)

1(L)

2(N)

AC220~240V
50/60Hz

COMPRESSOR

4-WAY

OUTDOOR
FAN MOTOR

Heat Pump Model


LED TYPE

GND

Vcc

RECEIVER

Vout

A B C

DISPLAY

SW(FORCE)

LED1
OPERATION

LED2
SLEEP

R15H

LED3
TIMER

C01A
104

HVB

R11H~R17H
220 1/8W

R11H

R12H

R13H

R14H

R16H

LED4
OUTDOOR

R17H

STEPPING MOTOR
(UP/DOWN)

-63-

RD

OR

YL

PK

BL

6
5
4

2
1

1
12V

HVB OUT

Force

receiver

AC PART

CN-12V

Option

CN-CONT

CN-HVB

CN-DISP2

CN-DISP1

CN-U/D

DC PART

Q11G
KRA107S

Q12G
KRA107S

Q13G
KRA107S

5V

20K 2012

R11H~R14H

5V

C02L
220uF SD
10V

5V

12V

HVB OUT

COMP

INDOOR FAN

Vcc
WP
SCL

+ C09D
220
10V SD

R11H

R12H

R13H

R14H

CAT24WC01J

EEPROM

SDA

3 A1
4 A0

1 G
2 A2

5V

IC01G
KID65004AF

IC01M
KID65004AF

C08D
103
25V

OJ1H

20K
R01P
2012

OJ3H

5V

IC04D
S78DL05L 1W
O
I
7805

OJ2H

20K
R02P
2012

5V

Force

5V

OJ4H

20K
R02F

103

C04C

C07D
103
25V

12V

12
13
14
15
16

7
8
9
10
11

2
3
4
5
6

2
4

4
5

5
1

1
CN-L/R

1
2

3 4 5 6 7

16 15 14 13 12 11 10 9

BL PK YL OR RD

FAN
A
V
d
d
1
A
V
s
s

B
Z

AVref

AVdd

RESET

X2

X1

Vss1

INT0

INT1

ZD02D
BZX55C11

R02D
20K
1/6W

DC LOW
VOLTAGE GND

C06D
330
25V SD

L1
ZBF503D

33

36
35
34

38
37

42
41
40
39

44
43

47
46
45

48

C03C
103

5V

5V

5V

DC HIGH
VOLTAGE GND

C03D
681

C03T
102

R01T
1K

SMPS

C02D
104
50V

R21H

R26H

R25H

R24H

R23H

R22H

FAN

OSC01B
CSTS0800MG03-T2
CRTL8.00MSOT

4WAY

R01B
1M

RY-4WAY

INT

D07D
UG2D
C04D
470/35V/SD

12V

INT

+ C02C
220uF
10V/SD

IC02D
TLP421(V4 BL)

L2
10nH

OR6H OR5H OR4H OR3H OR2H OR1H


Hi Med
Low O/L
F2
F1

C05D
472M

1
2

R03D
39
1/6W

5V

CN-ACDC

CN-ACDC2

5V

17 18 1920 21 22 23 24 25 26 27 28 29 30 31 32

Vdd0

Vss0

NEC
UPD780023AGC-C

12V

IC02M
KID65004AF

64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49

STEPPING MOTOR
(LEFT/RIGHT)

4WAY

Option

12V

12V

12V

IC01D
TNY266P

SD01D
STO2D-200

12V

R05H
10K

DC HIGH
VOLTAGE GND

S 2

BP 1

EN 4

D 5

RY-FAN

C01A
0.01
50V

C01D
4.7uF
450V/SD

INT

C02T
102

DC LOW
VOLTAGE GND

IC03D
TLP421(V4 BL)

NTC SCK-102

INDOOR FAN

INDOOR FAN

5V

IC01A
KIA7036P
S7136

5V

INT

5V

receiver

5V

BZ01E
PKM13EPY-4002

Q01T
C104S

Q04T
A104S

3.6V

R02H
12.1K
1%

R06D
56K

R07D
12K

R02A,20K

R04H
6.2K
1%

R02L,1K

R01L 5.1K

R02E,20

C01L
680pF/50V

R01E
1K

Q02T
A104S

RY-COMP

COMP

5V

R21H~R26H
12.1K, 1%

Q01C
KTC3198-Y
2SC5343

5V

Q03T
C104S

5V

R04D
27k
1/6W

5V

D05D
1N4007

D01T
1N4148

5V

D08D
LL4148

R05D
300K
1/4W
3216

R06D
300K
1/4W

D01C
IN4007

2
1

D01A
IN4007

CN-TH

CN-TEL

DC HIGH
VOLTAGE GND

C01T
104

ROOM-TH

D01D
IN4007

D01B
IN4007

PIPE-TH

R04J
560
1/4W

C02J
METAL FILM
47nM/275V/435D

INDOOR FAN

12V

NF01J
15mH/1A

CN-TELE

CN-PHONE

D01T

Q03T

C02T

TX

0.001uF
50V

R02J
100,1/2W

R03J
680
1/2W

5V

0.1uF/50V

R01T
1K

RY-HOOK

C06H

C01J
METAL FILM
100nM/275V/436D

IC01J
TLP762JF

A104S

5V

1K

C104S

5V

A104S

Q01T

Q04T

0.001uF
50V

C01T

C104S

Q02T

10K

R15H

BSP351L

R12H

C02H

RX

5V

RST

270

R01A

10uF
50V

RY-FAN
G5N-1A(G5NB-1A)

1uF
63V

PC01H

IC01A

RY-COMP

12V

C03J
METAL FILM
100nF/275V/436D

3
2

13

11

2
1

100K

R16H

C3198Y

R07H

2K

51K

OP1

C04H

RB3

RB2

RB1

RB0

VSS

MCLR

MICOM

VSS

NC

NC

X2

X1

VREF

VP

GS

RI

5V

10

11

12

13

14

15

100K

R01X

16

17

1M

R01B

5V

OSC01B

0.01uF
50V

C01X

CST-4.00MGW

RX

TX

SH-CAPACITOR

DE

Q0

Q1

Q2

Q3

DSO

0.1uF
50V

C02X

10 Q3

11 Q2

12 Q1

13 Q0

14

15

16

17

18

15

12

RY-COMP
G4A-1A-E-LG

RY-COMP

12V

CN-TAB1

TERMINAL BOARD

OE

D0

D1

D2

D3

DV

EST

RB4

RB5

RB6

RB7

VDD

OSC2

OSC1

RA0

RA1

PIC16C54CR

T0CLK

RA3

IC-DTMF
HT9170B

RA2

1uF
16V

1
2

(ST9170)
VN
18
VDD

DSO

DE

10K

OP2

10K

INDOOR
FAN
MOTOR

CST-3.58M

OSC02B

DE

BD

5V

R17H

R08H

100K

RST

5V

R01M
Q01M

4.7K

1N4004

5V

KIA7036P

5V

D01M

27

R06H

TLP621BL

CN-MOTOR

3.6V

R01J
120, 1/2W

100

R03A

4.7K

T1

C09H

27

R05H

2222A

Q02M
KTC2016

4.7K

R04H

Q03M

TRANS

R02A

5.1V, 1/2W

C01A +

1K

7.5K

ZD02H~ZD03H

0.1uF
50V

ZD02H

R02H
6.2K
1/4W

R03H

C03H
22uF
50V

ZD03H C11H

R13H

1.5KE56A

ZD01H

ZNR02J
TVR10561

0.15uF
63V

C08H

750

R14H

1N4004

D01H~D04H

RY-4WAY
G5N-1A(G5NB-1A)

ZNR01J
TVR10561

FUSE
250V/T2A

0.1uF/50V

T2
TR01J
TRAICS
SM1L43
T1

LM358

OP-AMP

1K

6.2K/1W

R01H

1uF DC250V

C01H
ZD05H

HR93F,5V
G6A-234P,5V

ZD04H

ZNR01

R09H

0.01uF
100V

C05H

100uF/25V

C01D

1N4148

5V

BD

2.7 1/2W

R18H

2.7 1/2W

R19H

3.9V, 1/2W

ZD04H~ZD05H

TELE (OPTION)

1(L)

2(N)

AC220~240V
50/60Hz

COMPRESSOR

4-WAY

OUTDOOR
FAN MOTOR

Heat Pump Model


HVB TYPE

Exploded View and Replacement Parts List


1. Indoor Unit
135312

152313

135314

152302
733010

131410
359011

267110

342800
159830

135311

159901
268712

346810

35211B

249951

135516

354212

TYPE B

TYPE A

249951
263230

352150

268714-2
146811-1

268714-1

146811-2

264110

268714-1

264110
266090

W6640

266090

268714-2

263232

263230

-64-

W0CZZ

Parts List(Indoor)
LOCATION No.

DESCRIPTION

PART No.
LS-Q076ABL

LS-Q076BBG

LS-Q076BEL

REMARKS

131410

CHASSIS ASSEMBLY

3141A20006A

3141A20006B

3141A20006A

135311

GRILLE ASSEMBLY, DISCHARGE(INDOOR)

3531A10127A

3531A10127E

3531A10127E

135312

GRILLE ASSEMBLY, FRONT(INDOOR)

3531A20101B

3531A20103B

3531A20101E

135314

GRILLE ASSEMBLY, INLET SUB

3531A20100B

3531A20102D

3531A20100C

135516

COVER ASSEMBLY, MOTOR

3551A20050H

3551A20050H

3551A20050H

146811

MOTOR ASSEMBLY, STEP

4681A20055A

4681A20055A

4681A20055A

152302

FILTER(MECH), A/C

5230A10005A

5230A10005A

5230A10005A

152313

FILTER ASSEMBLY, DEODORIZER

5231AR2412T

5231A30001C

5231A30001C

159830

AIR CLEANER ASSEMBLY

5983A10009B

5983A10009D

159901

VANE, HORIZONTAL

5990A10005A

5990A10005A

5990A10005A

249951

CONTROL BOX ASSEMBLY, INDOOR

4995A20199R
(4995A20257J)

4995A20199T
4995A20257K)

4995A20199T
4995A20257K)

263230

THERMISTOR ASSEMBLY

6323A20004A

6323A20004A

6323A20004A

264110

POWER CORD ASSEMBLY

6411A20013D
(6411A20026D)

6411A20013D
(6411A20026D)

6411A20013D
(6411A20026D)

266090

H.V ASSEMBLY

6609A10003J

6609A10003J

267110

REMOTE CONTROLLER ASSEMBLY

6711A20010B
(6711A20067G)

6711A20010F

6711A20010F

268712

PWB(PCB) ASSEMBLY, DISPLAY

6871A20194A
(6871A20194F)

6871A20227D
(6871A20227G)

6871A20227D
(6871A20227G)

268714-1

PWB(PCB) ASSEMBLY, MAIN(AC)

6871A20163A
(6871A20272J)

6871A20163A
(6871A20272J)

6871A20163A
(6871A20272J)

268714-2

PWB(PCB) ASSEMBLY, MAIN(DC)

6871A20218Q
(6871A20310B)

6871A20225L
(6871A20310C)

6871A20225L
(6871A20310C)

342800

BEARING

4280A20004A

4280A20004A

4280A20004A

346810

MOTOR ASSEMBLY, INDOOR

4681A20062D

4681A20062D

4681A20062D

352150

HOSE ASSEMBLY, DRAIN

5251AR2575F

5251AR2575F

5251AR2575F

354211

EVAPORATOR ASSEMBLY, BENDING

5421A10025C

5421A10025C

5421A10025G

359011

FAN ASSEMBLY, CROSS FLOW

5901A20007B

5901A20007B

5901A20007B

35211B

TUBE ASSEMBLY, TUBING

5211AR7066P

5211AR7066P

5211AR7066P

733010

PLATE ASSEMBLY, INSTALL

3301A10003A

3301A10003A

3301A10003A

W0CZZ

CAPACITOR, DRAWING

3H01487A

3H01487A

3H01487A

W6640

PWB(PCB) ASSEMBLY, MAIN(AC)

6871A20283A

6871A20283A

6871A20283A

NOTE) * Please ensure GCSC since these parts may be changed depending upon the buyer's request.
(GCSC WEBSITE http://biz.LGservice.com)
1) TYPE A : ~2002
2) TYPE B : 2003~

-65-

Parts List(Indoor)
LOCATION
No.

DESCRIPTION

131410 CHASSIS ASSEMBLY

PART No.
LS-Q096ABL LS-Q096BBG LS-Q096BEL LS-Q096AEM LS-Q096BEG

REMARKS

3141A20006A

3141A20006B

3141A20006A

3141A20006A

3141A20006A

135311 GRILLE ASSEMBLY, DISCHARGE(INDOOR) 3531A10127A

3531A10127E

3531A10127E

3531A10232J

3531A10127R

135312 GRILLE ASSEMBLY, FRONT(INDOOR)

3531A20101B

3531A20103B

3531A20101E

3531A10167C

3531A10225E

135314 GRILLE ASSEMBLY, INLET SUB

3531A20100B

3531A20102D

3531A20100C

3531A20142A

3531A20102X

135516 COVER ASSEMBLY, MOTOR

3551A20050H

3551A20050H

3551A20050H

3551A20050H

3551A20050H

146811 MOTOR ASSEMBLY, STEP

4681A20055A

4681A20055A

4681A20055A

4681A20055A

4681A20055A

152302 FILTER(MECH), A/C

5230A10005A

5230A10005A

5230A10005A

5230A10005A

5230A10005A

152313 FILTER ASSEMBLY, DEODORIZER

5231AR2412T

5231A30001C

5231A30001C

5231A30001C

5983A10009B

5983A10009D

5983A10009B

159901 VANE, HORIZONTAL

5990A10005A

5990A10005A

5990A10005A

5990A10005A

5990A10005A

249951 CONTROL BOX ASSEMBLY, INDOOR

4995A20199H
(4995A20257B)

4995A20199J 4995A20199J
(4995A20257D) (4995A20257D)

4995A20257G

4995A20257S

263230 THERMISTOR ASSEMBLY

6323A20004A

6323A20004A

6323A20004A

6323A20004K

6323A20004K

264110 POWER CORD ASSEMBLY

6411A20013D
(6411A20026D)

6411A20013D 6411A20013D
(6411A20026D) (6411A20026D)

6411A20026E

6411A20026E

159830 AIR CLEANER ASSEMBLY

266090 H.V ASSEMBLY

6609A10003J

6609A10003J

6609A10003N

267110 REMOTE CONTROLLER ASSEMBLY

6711A20010B
(6711A20067G)

6711A20010F
(6711A20067J)

6711A20010F
(6711A20067J)

6711A20012M

6711A20083G

268712 PWB(PCB) ASSEMBLY, DISPLAY

6871A20194A
(6871A20194F)

6871A20227D 6871A20227D
(6871A20227G) (6871A20227G)

6871A20390C

6871A20227G

268714-1 PWB(PCB) ASSEMBLY, MAIN(AC)

6871A20163A
(6871A20272A)

6871A20163A 6871A20163A
(6871A20272A) (6871A20272A)

6871A20272A

6871A20272A

268714-2 PWB(PCB) ASSEMBLY, MAIN(DC)

6871A20218H
(6871A20310G)

6871A20225N
(6871A20310J)

6871A20225N
(6871A20310J)

6871A20310G

6871A20310J

342800 BEARING

4280A20004A

4280A20004A

4280A20004A

4280A20004A

4280A20004A

346810 MOTOR ASSEMBLY, INDOOR

4681A20062A

4681A20062A

4681A20062A

4681A20062A

4681A20062A

352150 HOSE ASSEMBLY, DRAIN

5251AR2575F

5251AR2575F

5251AR2575F

5251AR2575F

5211AR7066P

354212 EVAPORATOR ASSEMBLY, BENDING

5421A10025B

5421A10025B

5421A10025E

5421A10025E

5251AR2575F

359011 FAN ASSEMBLY, CROSS FLOW

5901A20007B

5901A20007B

5901A20007B

5901A20007B

5421A10025E

35211B TUBE ASSEMBLY, TUBING

5211AR7066P

5211AR7066P

5211AR7066P

5211AR7066P

5901A20007B

733010 PLATE ASSEMBLY, INSTALL

3301A10003A

3301A10003A

3301A10003A

3301A10003A

3301A10003A

3H01487A

3H01487A

3H01487A

3H01487A

3H01487A

6871A20283A

6871A20283A

6871A20283A

6871A20283A

6871A20283A

W0CZZ CAPACITOR, DRAWING


W6640 PWB(PCB) ASSEMBLY, MAIN(AC)

NOTE) * Please ensure GCSC since these parts may be changed depending upon the buyer's request.
(GCSC WEBSITE http://biz.LGservice.com)
1) TYPE A : ~2002
2) TYPE B : 2003~

-66-

Parts List(Indoor)
LOCATION
No.

DESCRIPTION

131410 CHASSIS ASSEMBLY

PART No.
LS-Q096AHG LS-Q096ACG LS-Q096BAG LS-Q096ACL LS-Q096AAG

REMARKS

3141A20006B

3141A20006B

3141A20006B

3141A20006B

3141A20006A

135311 GRILLE ASSEMBLY, DISCHARGE(INDOOR) 3531A10127H

3531A10127H

3531A10127H

3531A10127H

3531A10127P

135312 GRILLE ASSEMBLY, FRONT(INDOOR)

3531A20103H

3531A20103A

3531A20103J

3531A20101K

3531A20103U

135314 GRILLE ASSEMBLY, INLET SUB

3531A20102H

3531A20102A

3531A20102J

3531A20100H

3531A20102A

135516 COVER ASSEMBLY, MOTOR

3551A20050H

3551A20050E

3551A20050E

3551A20050E

3551A20050E

146811 MOTOR ASSEMBLY, STEP

4681A20055A

4681A20055A

4681A20055A

4681A20055A

4681A20055A

152302 FILTER(MECH), A/C

5230A10005A

5230A10005A

5230A10005A

5230A10005A

5230A10005A

152313 FILTER ASSEMBLY, DEODORIZER

5231A30001C

5231AR2412T

159830 AIR CLEANER ASSEMBLY

5983A10009B

159901 VANE, HORIZONTAL

5990A10005A

5990A10005A

5990A10005A

5990A10005A

5990A10005A

249951 CONTROL BOX ASSEMBLY, INDOOR

4995A20199H
(4995A20257B)

4995A20199A 4995A20199Z
(4995A20257A) (4995A20257C)

4995A20232A

4995A20257A

263230 THERMISTOR ASSEMBLY

6323A20004A

6323A20004A

6323A20004A

6323A20004A

6323A20004L

264110 POWER CORD ASSEMBLY

6411A20013D
(6411A20026D)

6411A20013D 6411A20013D
(6411A20026D) (6411A20026D)

6411A20013D

6411A20026D

6609A10003J

266090 H.V ASSEMBLY

6609A10003J

267110 REMOTE CONTROLLER ASSEMBLY

6711A20010B
(6711A20067G)

6711A20010A 6711A20010E
(6711A20067E) (6711A20067H)

6711A20010A

6711A20067E

268712 PWB(PCB) ASSEMBLY, DISPLAY

6871A20194A
(6871A20390C)

6871A20194A 6871A20227D
(6871A20390C) (6871A20227G)

6871A20390A

6871A20294F

268714-1 PWB(PCB) ASSEMBLY, MAIN(AC)

6871A20163A
(6871A20272A)

6871A20163B 6871A20163B
(6871A20272K) (6871A20272K)

6871A20163B

6871A20272B
(6871A20283B)

268714-2 PWB(PCB) ASSEMBLY, MAIN(DC)

6871A20218H
(6871A20310G)

6871A20218A 6871A20225P
(6871A20310E) (6871A20310H)

6871A20218A

6871A20310E

342800 BEARING

4280A20004A

4280A20004A

4280A20004A

4280A20004A

4280A20004A

346810 MOTOR ASSEMBLY, INDOOR

4681A20062A

4681A20062A

4681A20062A

4681A20062A

4681A20062A

352150 HOSE ASSEMBLY, DRAIN

5251AR2575F

5251AR2575F

5251AR2575F

5251AR2575F

5251AR2575F

354211 EVAPORATOR ASSEMBLY, BENDING

5421A10025B

5421A10025B

5421A10025B

5421A10025B

5421A10025A

359011 FAN ASSEMBLY, CROSS FLOW

5901A20007B

5901A20007B

5901A20007B

5901A20007B

5901A20007B

35211B TUBE ASSEMBLY, TUBING

5211AR7066P

5211AR7066P

5211AR7066P

5211AR7066P

5211AR7066P

733010 PLATE ASSEMBLY, INSTALL

3301A10003A

3301A10003A

3301A10003A

3301A10003A

3301A10003A

3H01487A

3H01487A

3H01487A

3H01487A

3H01487A

6850A90001C

6871A20283B

6871A20283B

6871A20283B

6871A20283B

W0CZZ CAPACITOR, DRAWING


263232 CABLE, FLAT
W6640 PWB(PCB) ASSEMBLY, MAIN(AC)

NOTE) * Please ensure GCSC since these parts may be changed depending upon the buyer's request.
(GCSC WEBSITE http://biz.LGservice.com)
1) TYPE A : ~2002
2) TYPE B : 2003~

-67-

Parts List(Indoor)
LOCATION
No.

DESCRIPTION

131410 CHASSIS ASSEMBLY

PART No.
LS-Q096ABG LS-Q076ABG LS-Q082BAG LS-Q082BDL LS-N096QNA0

REMARKS

3141A20006A

3141A20006A

3141A20006A

3141A20006A

3141A20006A

135311 GRILLE ASSEMBLY, DISCHARGE(INDOOR) 3531A10127A

3531A10127A

3531A10127E

3531A10127A

3531A10127P

135312 GRILLE ASSEMBLY, FRONT(INDOOR)

3531A20101B

3531A20101B

3531A20103J

3531A20101T

3531A10194K

135314 GRILLE ASSEMBLY, INLET SUB

3531A20100B

3531A20100B

3531A20102J

3531A20100R

3531A20153K

135516 COVER ASSEMBLY, MOTOR

3551A20050H

3551A20050H

3551A20050E

3551A20050E

3551A20050H

146811 MOTOR ASSEMBLY, STEP

4681A20055A

4681A20055A

4681A20055A

4681A20055A

4681A20055A

152302 FILTER(MECH), A/C

5230A10005A

5230A10005A

5230A10005A

5230A10005A

5230A10005C

152313 FILTER ASSEMBLY, DEODORIZER

5231AR2412T

5231AR2412T

5231A30001C

5231A30001C

5983A10009B

5983A10009B

159901 VANE, HORIZONTAL

5990A10005A

5990A10005A

5990A10005A

5990A10005A

5990A10005A

249951 CONTROL BOX ASSEMBLY, INDOOR

4995A20199H
(4995A20257B)

4995A20199R
(4995A20257J)

4995A20199W

4995A20199L

4995A20257T

263230 THERMISTOR ASSEMBLY

6323A20004A

6323A20004A

6323A20004A

6323A20004A

6323A20004K

264110 POWER CORD ASSEMBLY

6411A20013D
(6411A20026D)

6411A20013D
(6411A20026D)

6411A20013D

6411A20013D

6411A20026E

6609A10003J

6609A10003J

267110 REMOTE CONTROLLER ASSEMBLY

6711A20010B
(6711A20067G)

6711A20010B
(6711A20067G)

6711A20010E

6711A20010E

6711A20028B

268712 PWB(PCB) ASSEMBLY, DISPLAY

6871A20194A
(6871A20194F)

6871A20194A
(6871A20194F)

6871A20391C

6871A20391C

6871A20194F

268714-1 PWB(PCB) ASSEMBLY, MAIN(AC)

6871A20163A
(6871A20272A)

6871A20163A
(6871A20272J)

6871A20163B

6871A20163B

6871A20272R

268714-2 PWB(PCB) ASSEMBLY, MAIN(DC)

6871A20218H
(6871A20310G)

6871A20218Q
(6871A20310B)

6871A20235A

6871A20225P

6871A20310G

342800 BEARING

4280A20004A

4280A20004A

4280A20004A

4280A20004A

4280A20004A

346810 MOTOR ASSEMBLY, INDOOR

4681A20062A

4681A20062D

4681A20062E

4681A20062A

4681A20062A

352150 HOSE ASSEMBLY, DRAIN

5251AR2575F

5251AR2575F

5251AR2575F

5251AR2575F

5211AR7066P

354211 EVAPORATOR ASSEMBLY, FINAL

5421A10025B

5421A10025C

5421A10025A

5421A10025F

5251AR2575F

359011 FAN ASSEMBLY, CROSS FLOW

5901A20007B

5901A20007B

5901A20007B

5901A20007B

5421A10025B

35211B TUBE ASSEMBLY, TUBING

5211AR7066P

5211AR7066P

5211AR7066P

5211AR7066P

5901A20007B

733010 PLATE ASSEMBLY, INSTALL

3301A10003A

3301A10003A

3301A10003A

3301A10003A

3301A10003A

3H01487A

3H01487A

3H01487A

3H01487A

3H01487A

263232 CABLE, FALT

6850A90001C

6850A90001C

6850A90001C

6850A90001C

W6640 PWB(PCB) ASSEMBLY, MAIN(AC)

6871A20283A

6871A20283A

6871A20283A

159830 AIR CLEANER ASSEMBLY

266090 H.V ASSEMBLY

W0CZZ CAPACITOR, DRAWING

NOTE) * Please ensure GCSC since these parts may be changed depending upon the buyer's request.
(GCSC WEBSITE http://biz.LGservice.com)
1) TYPE A : ~2002
2) TYPE B : 2003~

-68-

Parts List(Indoor)
LOCATION
No.

DESCRIPTION

131410 CHASSIS ASSEMBLY

PART No.
LS-Q096AEL

LS-Q096ADG LS-Q096ADL LS-Q096BDG LS-Q096ABM

REMARKS

3141A20006A

3141A20006B

3141A20006A

3141A20006B

3141A20006B

135311 GRILLE ASSEMBLY,DISCHARGE(INDOOR) 3531A10127A

3531A10127A

3531A10127A

3531A10127E

3531A10127P

135312 GRILLE ASSEMBLY,FRONT(INDOOR)

3531A20101B

3531A20103A

3531A20101A

3531A20103J

3531A10167F

135314 GRILLE ASSEMBLY,INLET SUB

3531A20100B

3531A20102A

3531A20100A

3531A20102J

3531A20142D

135516 COVER ASSEMBLY,MOTOR

3551A20050H

3551A20050E

3551A20050E

3551A20050E

3551A20050H

146811 MOTOR ASSEMBLY,STEP

4681A20055A

4681A20055A

4681A20055A

4681A20055A

4681A20055A

152302 FILTER(MECH),A/C

5230A10005A

5230A10005A

5230A10005A

5230A10005A

5230A10005A

152313 FILTER ASSEMBLY,DEODORIZER

5231A30001C

159830 AIR CLEANER ASSEMBLY

5983A10009B

159901 VANE,HORIZONTAL

5990A10005A

5990A10005A

5990A10005A

5990A10005A

5990A10005A

249951 CONTROL BOX ASSEMBLY,INDOOR

4995A20232C 4995A20199A 4995A20232B


(4995A20257G) (4995A20257A) (4995A20257A)

4995A20199L
(4995A20257C)

4995A20257B

263230 THERMISTOR ASSEMBLY

6323A20004A

6323A20004C

6323A20004C

6323A20004K

264110 POWER CORD ASSEMBLY

6411A20013T 6411A20013D 6411A20013T


(6411A20026E) (6411A20026D) (6411A20026D)

6411A20013D
(6411A20026D)

6411A20026D

266090 H.V ASSEMBLY

6323A20004A

6609A10003J

267110 REMOTE CONTROLLER ASSEMBLY

6711A20028B
(6711A20067S)

6711A20010A

6711A20028A

6711A20010E

6711A20010B

268712 PWB(PCB) ASSEMBLY,DISPLAY

6871A20194A 6871A20194A 6871A20194A 6871A20227D


(6871A20390C) (6871A20390C) (6871A20390C) (6871A20391G)

6871A20194F

268714-1 PWB(PCB) ASSEMBLY,MAIN(AC)

6871A20163A 6871A20163B 6871A20163B


(6871A20272A) (6871A20272K) (6871A20272K)

6871A20163B
(6871A20272K)

6871A20272A

268714-2 PWB(PCB) ASSEMBLY,MAIN(DC)

6871A20218H 6871A20218A 6871A20218A


(6871A20310G) (6871A20310E) (6871A20310E)

6871A20225P
(6871A20310H)

6871A20310G

342800 BEARING

4280A20004A

4280A20004A

4280A20004A

4280A20004A

4280A20004A

346810 MOTOR ASSEMBLY,INDOOR

4681A20062A

4681A20062A

4681A20062A

4681A20062A

4681A20062A

352150 HOSE ASSEMBLY,DRAIN

5251AR2575F

5251AR2575F

5251AR2575F

5251AR2575F

5251AR2575F

354211 EVAPORATOR ASSEMBLY,BENDING

5421A10025E

5421A10025F

5421A10025F

5421A10025F

5421A10025B

359011 FAN ASSEMBLY,CROSS FLOW

5901A20007B

5901A20007B

5901A20007B

5901A20007B

5901A20007B

35211B TUBE ASSEMBLY,TUBING

5211AR7066P

5211AR7066P

5211AR7066P

5211AR7066P

5211AR7066P

733010 PLATE ASSEMBLY,INSTALL

3301A10003A

3301A10003A

3301A10003A

3301A10003A

3301A10003A

3H01487A

3H01487A

3H01487A

3H01487A

3828A20243C

6850A90001C

3H01487A

6871A20283A

6871A20283B

6871A20283B

6871A20283B

6871A20283A

W0CZZ CAPACITOR,DRAWING
263232 CABLE,FLAT
W6640 PWB(PCB) ASSEMBLY, MAIN(AC)

NOTE) * Please ensure GCSC since these parts may be changed depending upon the buyer's request.
(GCSC WEBSITE http://biz.LGservice.com)
1) TYPE A : ~2002
2) TYPE B : 2003~

-69-

Parts List(Indoor)
LOCATION
No.

DESCRIPTION

131410 CHASSIS ASSEMBLY

PART No.
LS-Q082BAM LS-Q082AAL LS-Q082ACG

LS-Q082ACL LS-Q082ACM

REMARKS

3141A20006B

3141A20006B

3141A20006A

3141A20006A

3141A20006A

135311 GRILLE ASSEMBLY,DISCHARGE(INDOOR) 3531A10127R

3531A10127A

3531A10127A

3531A10127A

3531A10127A

135312 GRILLE ASSEMBLY,FRONT(INDOOR)

3531A10167G

3531A20101R

3531A20103G

3531A20101K

3531A10167H

135314 GRILLE ASSEMBLY,INLET SUB

3531A20142E

3531A20100P

3531A20102G

3531A20100H

3531A20142F

135516 COVER ASSEMBLY,MOTOR

3551A20050E

3551A20050E

3551A20050E

3551A20050E

3551A20050E

146811 MOTOR ASSEMBLY,STEP

4681A20055A

4681A20055A

4681A20055A

4681A20055A

4681A20055A

152302 FILTER(MECH),A/C

5230A10005A

5230A10005A

5230A10005A

5230A10005A

5230A10005A

152313 FILTER ASSEMBLY,DEODORIZER

5231A30001C

5231AR2412T

5231AR2412T

5231AR2412T

159830 AIR CLEANER ASSEMBLY

5983A10009C

159901 VANE,HORIZONTAL

5990A10005A

5990A10005A

5990A10005A

5990A10005A

5990A10005A

249951 CONTROL BOX ASSEMBLY,INDOOR

4995A20257N

4995A20232N

4995A20232R

4995A20232R

4995A20232R

263230 THERMISTOR ASSEMBLY

6323A20004L

6323A20004C

6323A20004C

6323A20004C

6323A20004C

264110 POWER CORD ASSEMBLY

6411A20015H

6411A20015B

3H03671F

3H03671F

3H03671F

267110 REMOTE CONTROLLER ASSEMBLY

6711A20069B

6711A20069A

6711A20067V

6711A20067V

6711A20067V

268712 PWB(PCB) ASSEMBLY,DISPLAY

6871A20391G

6871A20390A

6871A20390A

6871A20390A

6871A20390A

268714-1 PWB(PCB) ASSEMBLY,MAIN(AC)

6871A20272K

6871A20163B

6871A20163B

6871A20163B

6871A20163B

268714-2 PWB(PCB) ASSEMBLY,MAIN(DC)

6871A20310D

6871A20218V

6871A20218V

6871A20218V

6871A20218V

342800 BEARING

4280A20004A

4280A20004A

4280A20004A

4280A20004A

4280A20004A

346810 MOTOR ASSEMBLY,INDOOR

4681A20062E

4681A20062E

4681A20062E

4681A20062E

4681A20062E

352150 HOSE ASSEMBLY,DRAIN

5251AR2575F

5251AR2575F

5251AR2575F

5251AR2575F

5251AR2575F

354211 EVAPORATOR ASSEMBLY,FINAL

5421A10025A

5211AR7066P

5421A10025A

5421A10025A

5421A10025A

359011 FAN ASSEMBLY,CROSS FLOW

5901A20007B

5421A10025A

5901A20007B

5901A20007B

5901A20007B

35211B TUBE ASSEMBLY,TUBING

5211AR7066P

5901A20007B

5211AR7066P

5211AR7066P

5211AR7066P

733010 PLATE ASSEMBLY,INSTALL

3301A10003A

3301A10003A

3301A10003A

3301A10003A

3301A10003A

3H01487A

3H01487A

3H01487A

3H01487A

3H01487A

6871A20283B

W0CZZ CAPACITOR,DRAWING
W6640 PWB(PCB) ASSEMBLY, MAIN(AC)

NOTE) *Please ensure GCSC since these parts may be changed depending upon the buyer's request.
(GCSC WEBSITE http://biz.LGservice.com)

-70-

Parts List(Indoor)
LOCATION
No.

DESCRIPTION

PART No.
LS-C082QMA0

LS-C082QNA0

LS-C096QGL0

REMARKS

131410

CHASSIS ASSEMBLY

3141A20006A

3141A20006A

3141A20006A

135311

GRILLE ASSEMBLY,DISCHARGE(INDOOR)

3531A10232B

3531A10232B

3531A10232B

135312

GRILLE ASSEMBLY,FRONT(INDOOR)

3531A21013A

3531A21021A

3531A21013A

135314

GRILLE ASSEMBLY,INLET SUB

135516

COVER ASSEMBLY,MOTOR

3551A20099F

3551A20099F

3551A20099F

146811

MOTOR ASSEMBLY,STEP

4681A20055A

4681A20055A

4681A20055A

152302

FILTER(MECH),A/C

5230A10005A

5230A10005A

5230A10005A

152313

FILTER ASSEMBLY,DEODORIZER

5231A20032E

5231A20032E

5231A20032E

159830

AIR CLEANER ASSEMBLY

159901

VANE,HORIZONTAL

5990A10005A

5990A10005A

5990A10005A

249951

CONTROL BOX ASSEMBLY,INDOOR

4995A20232R

4995A20232R

4995A20232R

263230

THERMISTOR ASSEMBLY

6323A20004C

6323A20004C

6323A20004C

264110

POWER CORD ASSEMBLY

3H03671F

3H03671F

3H03671F

266090

H.V ASSEMBLY

267110

REMOTE CONTROLLER ASSEMBLY

6711A20067V

6711A20067V

6711A20067V

268712

PWB(PCB) ASSEMBLY,DISPLAY

6871A20390A

6871A20390A

6871A20390A

268714-1

PWB(PCB) ASSEMBLY,MAIN(AC)

6871A20163B

6871A20163B

6871A20163B

268714-2

PWB(PCB) ASSEMBLY,MAIN(DC)

6871A20218V

6871A20218V

6871A20218V

342800

BEARING

4280A20004A

4280A20004A

4280A20004A

346810

MOTOR ASSEMBLY,INDOOR

4681A20062E

4681A20062E

4681A20062E

35211B

TUBE ASSEMBLY,TUBING

5211A21046H

5211A21046H

5211A21046H

352150

HOSE ASSEMBLY,DRAIN

5251AR2575F

5251AR2575F

5251AR2575F

354211

EVAPORATOR ASSEMBLY,FINAL

5421A10038A

5421A10038A

5421A10038A

359011

FAN ASSEMBLY,CROSS FLOW

5901A20007E

5901A20007E

5901A20007E

733010

PLATE ASSEMBLY,INSTALL

3301A10003A

3301A10003A

3301A10003A

W0CZZ

CAPACITOR,DRAWING

3H01487A

3H01487A

3H01487A

263232

CABLE,FLAT

W6640

PWB(PCB) ASSEMBLY,SUB

6871A20283B

6871A20283B

6871A20283B

NOTE) *Please ensure GCSC since these parts may be changed depending upon the buyer's request.
(GCSC WEBSITE http://biz.LGservice.com)

-71-

Parts List(Indoor)
LOCATION
No.

DESCRIPTION

PART No.
LS-C096QLA0

LS-C096QNA0

LS-H096QGL1

REMARKS

131410

CHASSIS ASSEMBLY

3141A20006A

3141A20006C

3141A20006A

135311

GRILLE ASSEMBLY,DISCHARGE(INDOOR)

3531A10127P

3531A10127X

3531A10127R

135312

GRILLE ASSEMBLY,FRONT(INDOOR)

3531A21014E

3531A21021B

3531A20103B

135314

GRILLE ASSEMBLY,INLET SUB

3531A20102D

135516

COVER ASSEMBLY,MOTOR

3551A20050E

3551A20050E

3551A20050H

146811

MOTOR ASSEMBLY,STEP

4681A20055A

4681A20055A

4681A20055A

152302

FILTER(MECH),A/C

5230A10005A

5230A10005A

5230A10005A

152313

FILTER ASSEMBLY,DEODORIZER

5231A20032E

5231A20032E

5231A20032C

159830

AIR CLEANER ASSEMBLY

5983A10009V

159901

VANE,HORIZONTAL

5990A10005A

5990A10005A

5990A10005A

249951

CONTROL BOX ASSEMBLY,INDOOR

4995A20424B

4995A20424B

4995A20257U

263230

THERMISTOR ASSEMBLY

6323A20004L

6323A20004L

6323A20004K

264110

POWER CORD ASSEMBLY

6411A20043C

6411A20043C

6411A20026D

266090

H.V ASSEMBLY

6609A10003N

267110

REMOTE CONTROLLER ASSEMBLY

6711A20067E

6711A20067E

6711A20077L

268712

PWB(PCB) ASSEMBLY,DISPLAY

6871A20194F

6871A20194F

6871A20227G

268714-1

PWB(PCB) ASSEMBLY,MAIN(AC)

6871A20272K

6871A20272K

6871A20272A

268714-2

PWB(PCB) ASSEMBLY,MAIN(DC)

6871A20310E

6871A20310E

6871A20310M

342800

BEARING

4280A20004A

4280A20004A

4280A20004A

346810

MOTOR ASSEMBLY,INDOOR

4681A20062L

4681A20062L

4681A20062L

35211B

TUBE ASSEMBLY,TUBING

5211A21046H

5211A21046H

5211A21046H

352150

HOSE ASSEMBLY,DRAIN

5251AR2575F

5251AR2575F

5251AR2575F

354211

EVAPORATOR ASSEMBLY,FINAL

5421A10038A

5421A10038A

5421A10038G

359011

FAN ASSEMBLY,CROSS FLOW

5901A20007E

5901A20007E

5901A20007E

733010

PLATE ASSEMBLY,INSTALL

3301A10003A

3301A10003A

3301A10003A

W0CZZ

CAPACITOR,DRAWING

3H01487A

3H01487A

3H01487A

263232

CABLE,FLAT

W6640

PWB(PCB) ASSEMBLY,SUB

6871A20283B

6871A20283B

6871A20283A

NOTE) *Please ensure GCSC since these parts may be changed depending upon the buyer's request.
(GCSC WEBSITE http://biz.LGservice.com)

-72-

2. Outdoor unit
437210

552111

437212

552102
554031

435511

559010

546810

W0CZZ
649950

552116

567502
552202
554160
561410
550140

552203-1
552203-2

430410

-73-

Parts List(Outdoor)
LOCATION No.

DESCRIPTION

PART No.
LS-Q076ABL LS-Q076BBG LS-Q076BEL LS-Q076ABG

REMARKS

437210

GRILLE ASSEMBLY, FRONT(OUTDOOR)

3531AR2512R 3531AR2512R 3531AR2512R 3531AR2512R

546810

MOTOR ASSEMBLY, OUTDOOR

4681A20004F

4681A20004F

4681A20004F

4681A20004F

430410

BASE ASSEMBLY, WELD[OUTDOOR]

3041AR2415K

3041AR2415K

3041AR2415K

3041AR2415K

435511

COVER ASSEMBLY, CONTROL(OUTDOOR)

4994AR3492B

4994AR3492B

4994AR3492B

4994AR3492B

437212

PANEL ASSEMBLY, REAR(OUTDOOR)

3530AR0058C 3530AR0058C 3530AR0058C 3530AR0058C

550140

ISOLATOR, COMP

552102

4H00982E

4H00982E

4H00982E

4H00982E

TUBE, CAPILLARY BEND

5210A30151L

5210A30151L

5210A30151L

5210A30151L

552111

TUBE ASSEMBLY, CAPILLARY

5211A30082S

5211A30082S

5211A30082S

5211A30082S

552116

TUBE ASSEMBLY, REVERSING

5211A30095C

5211A30095C

5211A30095C

5211A30095C

552202

VALVE, REVERSING

5220AR3084A

5220AR3084A

5220AR3084A

5220AR3084A

552203-1

VALVE, SERVICE

2H02479F

2H02479F

2H02479F

2H02479F

552203-2

VALVE, SERVICE

2A00393M

2A00393M

2A00393M

2A00393M

5403AR2475L

5403AR2475L

554031

CONDENSER ASSEMBLY, BENT

5403AR2475L

5403AR2475L

554160

COMPRESSOR SET

2520UKYP2CA 2520UKYP2CA 2520UKYP2CA 2520UKYP2CA

559010

FAN ASSEMBLY, PROPELLER

5900AR1266A

5900AR1266A

5900AR1266A

5900AR1266A

561410

COIL ASSEMBLY, REVERSING VALVE

3A02028G

3A02028G

3A02028G

3A02028G

567502

O.L.P

6750U-L014A

6750U-L014A

6750U-L014A

6750U-L014A

649950

CONTROL BOX ASSEMBLY, OUTDOOR

4995A20031A

4995A20031A

4995A20031A

4995A20031A

W0CZZ

CAPACITOR, DRAWING

6120AR2194H 6120AR2194H 6120AR2194H 6120AR2194H

NOTE) *Please ensure GCSC since these parts may be changed depending upon the buyer's request.
(GCSC WEBSITE http://biz.LGservice.com)

-74-

Outdoor unit

437210

437212
554031

435301
435511

546810
552102-2
559010
649950
552201
552111
552102-1

552116

W0CZZ
552202
567502
561410
554160
447910
550140

552203-1

430410
552203-2

-75-

Parts List(Outdoor)
LOCATION
No.

DESCRIPTION

PART No.
LS-Q096ACG LS-Q096BAG LS-Q096ACL LS-Q082BAG LS-Q096ABM LS-H096QNA0

REMARKS

430410

BASE ASSEMBLY, WELD[OUTDOOR]

3041AR2415K 3041AR2415K 3041AR2415K 3041AR2415E 3041A20008K 3041A20016A

435301

GRILLE, DISCHARGE

3530A20006B 3530A20006B 3530A20006B 3530A20006B 3530A20006B 3530A10059D

435511

COVER ASSEMBLY, CONTROL(OUTDOOR) 4994AR3492B 4994AR3492B 4994AR3492B 4994AR3492B 3551A30023E 3551A30023Q

437210

PANEL ASSEMBLY, FRONT(OUTDOOR)

3531AR2512R 3531AR2512R 3531AR2512R 3531AR2512R 3721A20027A 3721A20060B

437212

PANEL ASSEMBLY, REAR(OUTDOOR)

3530AR0058B 3530AR0058B 3530AR0058B 3530AR0058B 3721A20026B 3721A20059A

447910

BARRIER ASSEMBLY, OUTDOOR

546810

MOTOR ASSEMBLY, OUTDOOR

550140

ISOLATOR, COMP

552102-1 TUBE, CAPILLARY BEND


552102-2 TUBE,CAPILLARY BEND

4971A30002B

4681A20004F 4681A20004F 4681A20004F 4681A20068A 4681A20004J 4791A20011A

4H00982E

4H00982E

4H00982E

4H00982E

4H00982E

4681A20004F

5210A21341A
5424AR7208M

4H00982E

5210A20595F

5211A30275D 5211A30275D 5211A30275D 5211A30337A 5211A20117E 5211A20133Z

5424AR3582H 5424AR3582H 5424AR3582H 5424AR3582C


-

552111

TUBE ASSEMBLY, CAPILLARY

552116

TUBE ASSEMBLY, REVERSING

552201

VALVE, CHECK

552202

VALVE, REVERSING

552203-1 VALVE, SERVICE

2H02479F

2H02479F

2H02479F

2H02479F

2H02479H

2H02479N

552203-2 VALVE, SERVICE

2A00393U

2A00393U

2A00393U

2A00393U

2A00393U

2A00393Z

5211A20116C 5211A21027B
3H01552F

5220AR3084A 5220AR3084E

R
R
R

554031

CONDENSER ASSEMBLY, BENT

5403AR2870F 5403AR2870M 5403AR2870F 5403AR2870P 5403A20028H 5403A20059B

554160

COMPRESSOR SET

5416A20013L 5416A20013L 5416A20013L 5416A20013J 5416A20013C 5417A20012H

559010

FAN ASSEMBLY, PROPELLER

5900AR1266A 5900AR1266A 5900AR1266A 5900AR1266A 5901A10004A 5900AR1266A

561410

COIL ASSEMBLY, REVERSING VALVE

567502

O.L.P

6750A30001C 6750A30001C 6750A30001C 6750A30001C 6750A30001C 6750A30001C

649950

CONTROL BOX ASSEMBLY, OUTDOOR

4995AR2566B 4995AR2566B 4995AR2566B 4995AR2566E 4995A20083F 4995A10032J

W0CZZ CAPACITOR, DRAWING

2H01451P

2H01451P

2H01451P

2H01451P

3A02028Y

2H01451P

3A02028Y

2H01451P

NOTE) *Please ensure GCSC since these parts may be changed depending upon the buyer's request.
(GCSC WEBSITE http://biz.LGservice.com)

-76-

Parts List(Outdoor)
LOCATION
No.

DESCRIPTION

PART No.
LS-Q096ABL LS-Q096BBG LS-Q096BEL LS-Q096AHG LS-Q096ABG LS-Q096AEM

REMARKS

430410

BASE ASSEMBLY, OUTDOOR

3041A20008K 3041A20008K 3041A20008K 3041A20008K 3041A20008K 3041A20008K

435511

COVER ASSEMBLY, CONTROL(OUTDOOR) 3551A30023E 3551A30023E 3551A30023E 3551A30023E 3551A30023E 3551A30023E

437210

PANEL ASSEMBLY, FRONT(OUTDOOR)

3721A20027A 3721A20027A 3721A20027A 3721A20027A 3721A20027A 3721A20027A

437212

PANEL ASSEMBLY, REAR(OUTDOOR)

3721A20026B 3721A20026B 3721A20026B 3721A20026B 3721A20026B 3721A20026B

447910

BARRIER ASSEMBLY, OUTDOOR

4791A30002B 4791A30002B 4791A30002B 4791A30002B 4791A30002B 4791A30002B

546810

MOTOR ASSEMBLY, OUTDOOR

4681A20004J 4681A20004J 4681A20004J 4681A20004J 4681A20004J 4681A20004J

550140

ISOLATOR, COMP

552111

TUBE ASSEMBLY, CAPILLARY

5211A20117C 5211A20117C 5211A20117C 5211A20117C 5211A20117C 5211A20117E

552116

TUBE ASSEMBLY, REVERSING

5211A20116A 5211A20116A 5211A20116A 5211A20116A 5211A20116A 5211A20116C

552201

VALVE, CHECK

552202

VALVE, REVERSING

4H00982E

3H01552F

4H00982E

3H01552F

4H00982E

3H01552F

4H00982E

3H01552F

4H00982E

3H01552F

4H00982E

3H01552F

5220AR3084A 5220AR3084A 5220AR3084A 5220AR3084A 5220AR3084A 5220AR3084A

R
R

552203-1 VALVE, SERVICE

2H02479H

2H02479H

2H02479H

2H02479H

2H02479H

2H02479H

552203-2 VALVE, SERVICE

2A00393U

2A00393U

2A00393U

2A00393U

2A00393U

2A00393U

552102-1 TUBE,CAPILLARY BEND

5210A21341A

552102-2 TUBE,CAPILLARY BEND

5424AR7208M

554031

CONDENSER ASSEMBLY, BENT

5403A20028H 5403A20028H 5403A20028H 5403A20028B 5403A20028B 5403A20028H

554160

COMPRESSOR

5416A20013C 5416A20013C 5416A20013C 5416A20013C 5416A20013C 5416A20013C

559010

FAN ASSEMBLY, PROPELLER

5901A10004A 5901A10004A 5901A10004A 5901A10004A 5901A10004A 5901A10004A

561410

COIL ASSEMBLY, REVERSING VALVE

567502

O.L.P

649950

CONTROL BOX ASSEMBLY, OUTDOOR

W0CZZ CAPACITOR, DRAWING


435301

GRILLE, DISCHARGE

3A02028Y

3A02028Y

3A02028Y

3A02028Y

3A02028Y

3A02028Y

6750A30001C

4995A20083F 4995A20083F 4995A20083F 4995A20083F 4995A20083F 4995A20083F

2H01451P

2H01451P

2H01451P

2H01451P

2H01451P

2H01451P

3530A20006B 3530A20006B 3530A20006B 3530A20006B 3530A20006B 3530A20006B

NOTE) *Please ensure GCSC since these parts may be changed depending upon the buyer's request.
(GCSC WEBSITE http://biz.LGservice.com)

-77-

R
R

Parts List(Outdoor)
LOCATION
No.

PART No.

DESCRIPTION

LS-Q096AEL LS-Q096ADG LS-Q096ADL

LS-Q096BDG
LS-Q096AAG LS-Q096BEG
LS-Q096BDL

3041A20008K 3041AR2415K 3041AR2415K 3041AR2415K 3041AR2415K 3041A20008K

REMARKS

430410

BASE ASSEMBLY,OUTDOOR

435301

GRILLE,DISCHARGE

435301

GRILLE,DISCHARGE

3530A20006B 3530A20006B 3530A20006B 3530A20006B

435511

COVER ASSEMBLY,CONTROL(OUTDOOR)

3551A30023E 4994AR3492B 4994AR3492B 4994AR3492B 4994AR3492B 3551A30023E

437210

PANEL ASSEMBLY,FRONT(OUTDOOR)

3721A20027A 3531AR2512R 3531AR2512R 3531AR2512R 4994AR3492B 3721A20027A

437212

PANEL ASSEMBLY,REAR(OUTDOOR)

3721A20026B 3530AR0058B 3530AR0058B 3530AR0058B 3530AR0058B 3721A20026B

447910

BARRIER ASSEMBLY,OUTDOOR

546810

MOTOR ASSEMBLY,OUTDOOR

550140

ISOLATOR,COMP

3530A20006B

4681A20004J 4681A20004F 4681A20004F 4681A20004F 4681A20004F 4681A20004J

4H00982E

4H00982E

4791A30002B

4H00982E

4H00982E

4H00982E

4H00982E

552102-1 TUBE,CAPILLARY BEND

5210A21341A 5424AR3582H 5424AR3582H 5424AR3582H 5424AR3582H 5210A21341A

552102-1 TUBE,CAPILLARY BEND

5424AR7208M

5424AR7208M

552111

TUBE ASSEMBLY,CAPILLARY

5211A20117C 5211A30275D 5211A30275D 5211A30275D 5211A30275D 5211A20117E

552116

TUBE ASSEMBLY,REVERSING

5211A20116A

5211A20116C

552201

VALVE,CHECK

3H01552F

3H01552F

552202

VALVE,REVERSING

5220AR3084A

5220AR3084A

552203-1 VALVE,SERVICE

2H02479H

2H02479F

2H02479F

2H02479F

2H02479F

2H02479H

552203-2 VALVE,SERVICE

2A00393U

2A00393U

2A00393U

2A00393U

2A00393U

2A00393U

554031

CONDENSER ASSY,BENT

5403A20028H 5403AR2870M 5403AR2870M 5403AR2870M 5403AR2870M 5403A20028H

554160

COMPRESSOR

5416A20013C 5416A20013L 5416A20013L 5416A20013L 5416A20013L 5416A20013C

559010

FAN ASSEMBLY,PROPELLER

5901A10004A 5900AR1266A 5900AR1266A 5900AR1266A 5900AR1266A 5901A10004A

561410

COIL ASSEMBLY,REVERSING VALVE

567502

O.L.P

6750A30001C 6750A30001C 6750A30001C 6750A30001C 6750A30001C 6750A30001C

649950

CONTROL BOX ASSEMBLY,OUTDOOR

4995A20083F 4995AR2566F 4995AR2566F 4995AR2566F 4995AR2566F 4995A20083F

W0CZZ

CAPACITOR,DRAWING

3A02028Y

2H01451P

2H01451P

2H01451P

2H01451P

2H01451P

3A02028Y

2H01451P

NOTE) *Please ensure GCSC since these parts may be changed depending upon the buyer's request.
(GCSC WEBSITE http://biz.LGservice.com)

-78-

Parts List(Outdoor)
LOCATION
No.

DESCRIPTION

430410 BASE ASSY,WELD[OUTDOOR]

PART No.
LS-Q082BAM LS-Q082AAL LS-Q082ACG LS-Q082ACL LS-Q082ACM

REMARKS

3041AR2415E

3041AR2415E

3041AR2415E

3041AR2415E

3041AR2415E

435511 COVER ASSEMBLY,CONTROL(OUTDOOR) 4994AR3492B

4994AR3492B

4994AR3492B

4994AR3492B

4994AR3492B

437210 GRILLE ASSEMBLY,FRONT(OUTDOOR)

3531AR2512R

3531AR2512R

3531AR2512R

3531AR2512R

3531AR2512R

437212 PANEL ASSEMBLY,REAR(OUTDOOR)

3530AR0058B

3530AR0058B

3530AR0058B

3530AR0058B

3530AR0058B

546810 MOTOR ASSEMBLY,OUTDOOR

4681A20068A

4681A20068A

4681A20068A

4681A20068A

4681A20068A

4H00982E

4H00982E

4H00982E

4H00982E

4H00982E

552102-1 TUBE,CAPILLARY BEND

5424AR3582C

5424AR3582C

5424AR3582C

5424AR3582C

5424AR3582C

552102-2 TUBE,CAPILLARY BEND

552111 TUBE ASSY,CAPILLARY

5211A30337A

5211A30337A

5211A30337A

5211A30337A

5211A30337A

552203-1 VALVE,SERVICE

2H02479F

2H02479F

2H02479F

2H02479F

2H02479F

552203-2 VALVE,SERVICE

2A00393U

2A00393U

2A00393U

2A00393U

2A00393U

554031 CONDENSER ASSEMBLY,BENT

5403AR2870P

5403AR2870P

5403AR2870H

5403AR2870H

5403AR2870H

554160 COMPRESSOR

5416A20013J

5416A20013J

5416A20013J

5416A20013J

5416A20013J

559010 FAN ASSEMBLY,PROPELLER

5900AR1266A

5900AR1266A

5900AR1266A

5900AR1266A

5900AR1266A

567502 O.L.P

6750A30001D

6750A30001D

6750A30001D

6750A30001D

6750A30001D

649950 CONTROL BOX ASSEMBLY,OUTDOOR

4995AR2566E

4995AR2566E

4995AR2566E

4995AR2566E

4995AR2566E

W0CZZ CAPACITOR,DRAWING

6120AR2194G

6120AR2194G

6120AR2194G

6120AR2194G

6120AR2194G

550140 ISOLATOR,COMP

NOTE) *Please ensure GCSC since these parts may be changed depending upon the buyer's request.
(GCSC WEBSITE http://biz.LGservice.com)

-79-

Parts List(Outdoor)
LOCATION
No.

DESCRIPTION

PART No.

REMARKS

LS-C082QMA0

LS-C082QNAO

LS-C096QGL0

3041AR2415E

3041AR2415E

3041AR2415K

430410

BASE ASSY,WELD[OUTDOOR]

435301

GRILLE,DISCHARGE

435511

COVER ASSEMBLY,CONTROL(OUTDOOR)

4994AR3492B

4994AR3492B

4994AR3492B

437210

GRILLE ASSEMBLY,FRONT(OUTDOOR)

3531AR2512R

3531AR2512R

3531AR2512R

437212

PANEL ASSEMBLY,REAR(OUTDOOR)

3530AR0058B

3530AR0058B

3530AR0058B

546810

MOTOR ASSEMBLY,OUTDOOR

4681A20068K

4681A20068K

4681A20004F

550140

ISOLATOR,COMP

4H00982E

4H00982E

4H00982E

552102

TUBE,CAPILLARY BEND

5424AR3582C

5424AR3582C

5424AR3582H

552102-1 TUBE,CAPILLARY BEND

552102-2 TUBE,CAPILLARY BEND

552111

TUBE ASSY,CAPILLARY

5211A30337A

5211A30337A

5211A30275D

552116

TUBE ASSY,REVERSING

552201

VALVE,CHECK

552202

VALVE,REVERSING

552203-1 VALVE,SERVICE

2H02479F

2H02479F

2H02479F

552203-2 VALVE,SERVICE

2A00393U

2A00393U

2A00393U

554031

CONDENSER ASSEMBLY,BENT

5403AR2870H

5403AR2870H

5403AR2870M

554160

COMPRESSOR

5416A20013J

5416A20013J

5416A20013L

559010

FAN ASSEMBLY,PROPELLER

5900AR1266A

5900AR1266A

5900AR1266A

561410

COIL ASSY,REVERSING VALVE

567502

O.L.P

6750A30001D

6750A30001D

6750A30001C

649950

CONTROL BOX ASSEMBLY,OUTDOOR

4995AR2566N

4995AR2566N

4995AR2566F

W0CZZ

CAPACITOR,DRAWING

6120AR2194G

6120AR2194G

2H01451P

NOTE) *Please ensure GCSC since these parts may be changed depending upon the buyer's request.
(GCSC WEBSITE http://biz.LGservice.com)

-80-

Parts List(Outdoor)
LOCATION
No.

DESCRIPTION

PART No.

REMARKS

LS-C096QLA0

LS-C096QNA0

LS-H096QGL1

3041AR2415K

3041AR2415K

3041A20016A

3530A10059G

430410

BASE ASSY,WELD[OUTDOOR]

435301

GRILLE,DISCHARGE

435511

COVER ASSEMBLY,CONTROL(OUTDOOR)

4994AR3492B

4994AR3492B

3551A30023Q

437210

GRILLE ASSEMBLY,FRONT(OUTDOOR)

3531AR2512R

3531AR2512R

3720A10171A

437212

PANEL ASSEMBLY,REAR(OUTDOOR)

3530AR0058B

3530AR0058B

3720A10172A

546810

MOTOR ASSEMBLY,OUTDOOR

4681A20004F

4681A20004F

4681A20121A

550140

ISOLATOR,COMP

4H00982E

4H00982E

4H00982E

552102

TUBE,CAPILLARY BEND

5424AR3582H

5424AR3582H

5210A20595F

552102-1 TUBE,CAPILLARY BEND

552102-2 TUBE,CAPILLARY BEND

552111

TUBE ASSY,CAPILLARY

5211A30275D

5211A30275D

5211A20133Z

552116

TUBE ASSY,REVERSING

5211A21027B

552201

VALVE,CHECK

552202

VALVE,REVERSING

5220AR3084E

552203-1 VALVE,SERVICE

2H02479F

2H02479F

2H02479P

552203-2 VALVE,SERVICE

2A00393U

2A00393U

5220A20040A

554031

CONDENSER ASSEMBLY,BENT

5403AR2870M

5403AR2870M

5403A20059F

554160

COMPRESSOR

5416A20013L

5416A20013L

5416A20013L

559010

FAN ASSEMBLY,PROPELLER

5900AR1266A

5900AR1266A

5900AR1266A

561410

COIL ASSY,REVERSING VALVE

3A02028Y

567502

O.L.P

6750A30001C

6750A30001C

6750A30001C

649950

CONTROL BOX ASSEMBLY,OUTDOOR

4995AR2566F

4995AR2566F

4995A10032J

W0CZZ

CAPACITOR,DRAWING

2H01451P

2H01451P

2H01451P

NOTE) *Please ensure GCSC since these parts may be changed depending upon the buyer's request.
(GCSC WEBSITE http://biz.LGservice.com)

-81-

P/No.: 3828A20178A

April, 2004
Printed in Korea

S-ar putea să vă placă și