Sunteți pe pagina 1din 2

Profibus DP Slave

8 digital inputs, 4 digital outputs

24 V DC supply
______________________
x1

OUT

78

78

456

US

A
B

4(+)

UL

3()

Digital output
___________

456

IN

x1
901

23

23

901

Digital input
__________
3()
4( )

BF
A

A
DIA

2( )
3()

1(+)

Digital input
____________
3()
4( )

__
___
1(+)
__
___
__
2( )
___
___ ___PROFIBUS DP output
___ _________________
__PROFIBUS DP input
________________

These items are PROFIBUS DP slaves.


Up to 8 digital inputs (see also item nos. 755-881/755-888) can be used to
connect standard 3-conductor PNP sensors. As an alternative, up to 4 digital
inputs can be used to connect standard 4-conductor PNP sensors.
Furthermore, the module has 4 digital outputs allowing the connection of DC
actuators. The inputs and outputs are connected via M12 circular connectors.
The current supply of the sensors as well as the outputs are short-circuit-proof.
A sensor short circuit is indicated by a collective LED. An actuator short circuit
is indicated by LEDs for each channel. The status of the inputs is also indicated
by LEDs for each channel.

The fieldbus is connected via M12 circular connectors. The status of the
fieldbus is indicated by a LED.
The supply voltage is supplied to the module by a M23 circular connector.
Various LEDs indicate the channel status.
The power supply of the fieldbus, of the module electronics, and of the sensors
are electrically isolated from each other. The power supply of the actuators is
separate.

Note: GSD files required

Description

Item no.

Pack.
unit

System Data

PROFIBUS DP Slave 8DI 24V + 4DO 24V


DC 2A with address switch
PROFIBUS DP Slave 8DI 24V + 4DO 24V
DC 2A (without illustration)

755-105

Total length

755-102

1
Topology
No. of couplers connected to Master
Addressing

Baud rate
Communication

Accessories

Item no.

Addressing device
Bus cable, power supply cable
Sensor/actuator cable
other accessories
GSD files

Page 412
Page 413
see section 7, pages 439 ... 446
Page 416
Download: www.wago.com

User hierarchy
Cycle time
Transmission medium
Terminating resistor

depends on baud rate and use of


repeater ;
example: 400 m for 500 kbaud;
100 m for 12 Mbaud
Line structure
32 without repeater
Address switch (755-105);
Addressing device (item no. 755-201);
Configuration software
9.6 kbaud ... 12 Mbaud
Master-slave procedure with cyclical
polling
Master-slave level
depends on number of devices and baud
rate
certified Cu cable
yes

Standards and Approvals


Standard
Certification
Conformity marking

Subject to design changes


10.09.2008

EN 50170
PNO
1

WAGO Kontakttechnik GmbH & Co. KG

Postfach 2880 D-32385 Minden Tel.: +49(0)571/887-0


E-Mail: info@wago.com
Hansastr. 27 D-32423 Minden Fax: +49(0)571/887-169 www.wago.com

Basic wiring diagram of an input


Digital
input
3
2

Digital
output

4
5

Digital input

24 VDC supply
4
5

M 12

1
6
2
3

+24 V

_______
Function

___
Pin

_______
Function

___
Pin

_______
Function

1
2
3
4
5

+24 V
Signal B
0V
Signal A
Earth

1
2
3
4
5

n.c.
n.c.
0V
Signal
Earth

1
2
3
4

Earth
+ 24 V (actuators)
0 V (actuators)
+24 V (module supply +
sensors)
0 V (module supply +
sensors)
n.c.

4
1

0V
Signal
Earth

3
2

___
Pin

_______
Function

1
2
3
4
5

+5 V*
Line A
GND*
Line B
Earth

4
1

Pin 3

0V
1A

Pin 4

DIA
Logic

Pin 5

Earth

Digital output

5
3

+24 V

Basic wiring diagram of an output

PROFIBUS DP
Output
Input
5

Pin 1

M 23

___
Pin

Supply

M 12 B-coded

Actuator supply indication (US)


Outputs
Nominal output current
Max. current comsumption per
Number of channels
Type of channel
Status indication for each channel

0V
2
Logic

Fn Status

Signal

Earth

Technical Data

ID
Power supply - electronics
Nominal voltage
Voltage range
Current consumption
Reverse voltage protection
Operating indicator (UL)
Power supply - sensors
Nominal voltage (Vs)
Voltage range
Total current of all sensors
Short circuit protection
Sensor short circuit indication (DIA)
Inputs
Nominal input voltage
Input
Number of digital channels
Status indication for each channel
Power supply - actuators
Nominal voltage
Voltage range
Electrical insulation
Reverse voltage protection

Pin 3

2A

* Internal signals

Bus system
Address range

0V

Supply

Pin 4

Pin 5

+ 24 V

Earth

Technical Data
1...126 dec, default 99 (755-105)
1...126 dec, default 126 (755-102)
B755 hex
DC 24 V
DC 19 V ... 28.8 V
max. 60 mA
yes
LED green
DC 24 V
DC 19 V ... 28.8 V
max. 800 mA
yes
LED red

General specifications
Degree of protection
Ambient operating temperature
Weight
Dimensions (mm) W x H x L

Diagnostic indication
LED 1, 3, 5, 7 A/B
LED 2, 4, 6, 8 A
LED 2, 4, 6, 8
LED US
LED UL
LED BF
LED DIA

DC 24 V
high-side switching
8
LED yellow

Bit assignment
Byte 0
Byte 1

DC 24 V
DC 15 V ... 30 V
yes
yes (unregulated power supply unit
required, 10 A medium time-lag fuse)
LED green
2 A per channel (max. 2.4 A)
8A
4
PNP, positive switched; short circuit proof
LED yellow

Byte 7 (diagnostic message)

IEC IP 67 (NEMA Type 4-6 P)


0 C ... +60 C
645,8 g (755-105)
504 g (755-102)
60 x 197* x 51 (755-105)
60 x 170* x 51 (755-102)
* including flange sockets
Indicator yellow: channel active
Indicator yellow: channel active
Indicator red: actuator short circuit
Indicator green: actuator supply active
Indicator green: module supply active
Indicator red: bus error /no data
exchange
Indicator red: module diagnosis
(e.g. sensor short circuit)
Bit 0 ... 3 / Actuator 2, 4, 6, 8
(Bit 4 ... 7 / n.c.)
Bit 0 ... 7 / Sensor 1A, 3A, 5A, 7A, 1B,
3B, 5B, 7B
Bit 4 / Diagnosis: sensor overload,
Bit 5 / Diagnosis: actuator overload,
Bit 6 / Diagnosis: low voltage detection

S-ar putea să vă placă și