Sunteți pe pagina 1din 6

Portable X-ray NDT Equipment

Overview
Frequency conversion air insulation portable X-ray detection machine can be widely
used in shipbuilding, machinery manufacturing, aviation, rail, pressure vessels, boilers,
oil, chemical, defense industry and other departments for non-destructive testing.
Particularly applicable to construction site operation and high-altitude operations.
In this series of ndt machine, X-ray generator adopt the SF6 gas
insulated and anode grounded technology, forced cooling fan;
controller uses an advanced computer control systems, SCR voltage
regulator modules, main and auxiliary thyristor inverter control and
regulation, steady flow advanced electronic circuits, interference
lines. Overall performance has been significantly improved.

Structures:
1.X-ray Generator
2.Controller
3.Connecting Cable
4.Power Cable

Key Featurers:

1.Controller
(1)The special design of high frequency technology
can avoid the interference by power spikes.Even
though the voltage changes,it can still work.
(2)All the signal wires in the
controller are imported from South Korea to improve
the quality.
(3)Take the isolation technology of the low voltag
e and the high voltage to ensure the controller working steady.
(4)Posses the reliable "timedelayed" function, suitable to operate in the open field.
(5)High degree of automation with the function of trouble shooting an
d indication.
(6)Controller adopts design of hardware with a wide operative
range,having the advantage of long service and low failure rate.
(7)Strictly comply with 1:1 working/resting regulation,eliminating
the disoperation.

2.Generator
(1)Safe and reliable generator adopts design of SF6
gaseous insulator,grounded-anode,and air fan
cooling.
(2)High purity and high density aluminium radiator
is specially designed for our instrument.High
temperature installation technology is adopted to
improve 30% heat radiation.

(3)The HV coils made by imported enamel wire are applied in the X-ray
generator,so as to make the quality of the complete equipment
improved a great deal.

3.Connecting Cable
The length is 25m,much longer than the limited
length by the international standard.It can
guarantee the safety of the operator.

Parameters

Classify

Glass tube
directional

Beam
angle

40

XXQ-1005

40-100

1.0

1.0*1.0

Max.
penetr
ation
A3
steel
(mm)
8

XXQ-1605

60-160

1.5

1.5*1.5

20

210*210*620

15

XXQ-2005

80-200

2.0

1.5*1.5

29

290*290*680

23

XXQ-2505

130-250

2.5

2.0*2.0

39

320*320*730

35

XXQ-3005

150-300

3.0

2.5*2.5

49

340*340*850

43

Model

Tube
voltage
(KV)

Capaci
ty
(KW)

Focus
size
(mm)

X-ray generator
Size
(mm)

Weight
(kg)

180*180*540

10

Glass tube
panoramic
with flat
target

Glass tube
panoramic
with cone
target

360*25

360*40

Ceramic
tube
directional

40

XXQ-3505

200-350

3.5

2.5*2.5

59

340*340*820

42

XXH-1005

40-100

1.0

1.0*1.5

160*160*520

11

XXH-1605

60-160

1.5

1.0*2.0

18

210*210*620

15

XXH-2005

80-200

2.0

1.0*2.0

26

270*270*665

20

XXH-2505

130-250

2.5

1.0*2.4

36

330*330*750

32

XXH-3005

150-300

3.0

1.0*2.5

46

330*330*765

41

XXH-3505

200-350

3.5

1.0*2.5

56

340*340*820

42

XXHA-1605

60-160

1.5

1.0*3.5

15

210*210*620

15

XXHA-2005

80-200

2.0

1.0*3.5

24

290*290*685

23

XXHA-2505

130-250

2.5

1.0*5.0

34

330*330*750

35

XXHA-3005

150-300

3.0

1.0*6.0

40

340*340*850

41

XXHA-3505

200-350

3.5

1.0*6.0

50

340*340*850

42

XXG-1605

60-160

1.5

1.5*1.5

20

230*200*570

14

XXG-2005

80-200

2.0

1.5*1.5

29

290*290*620

26

XXG-2505

130-250

2.5

2.0*2.0

39

330*330*710

32

XXG-3005

150-300

3.0

2.5*2.5

49

340*340*850

37

XXG-3505

200-350

3.5

2.5*2.5

59

330*330*670

38

Tube Current

5mA

Power Supply

AC220V 10% 50HZ

Controller
Size (mm)
Controller
Weight (kg)
Insulating
Material
Working
Temperature
Relative
Humidity
Standard
Condition
Safe Pressure

367320164
13kg
SF6 gas
-25~ +40
85%
1. Focus : 600mm
2. Time of exposure :5min
3. Film :Kodak brand film, double-sided lead film
4. Film Developing : temperature 2, developing 5min ,Density 2.0

0.35-0.50 MPa(Prohibition of use when it is lower than 0.35 MPa)

Working principle description


1 The controller using Silicon controlled rectifier bridge single-phase electric
appliances, the rectified voltage is smoothed by the LC filter circuit into a DC voltage.
The voltage of the thyristor chopper circuit into a variable
frequency pulse in one direction, to give high-voltage pulse
transformer as the X-ray generator power supply.
Milliamps (mA) units can change unidirectional pulse frequency with
the increase or decrease of x ray tube heating voltage, to ensure the
stability of X-ray tube current.
Kilovolt (kV) control unit can continuously control the tube voltage
level to meet the requirements of different materials radiography.
Anti-jamming loop Enhanced the control system ability to against high
-voltage shock from the X-ray generator ,

X-ray generator adopts prevents shock type. X-ray tube anode

grounded, and has over-temperature protection device. Once the


temperature is excessively high, the controller can automatically cut
off the pressure, to prevent X-ray tube damage due to overheating.

The power supply voltage fluctuations can be automatically

adjusted by the controller itself, in order to get a stable X-ray.


Exposure time and the state machine are controlled by asingle-chip
micro-computer, pre-exposure time of up to 5 minutes.

Configuration
Spare Parts

Quantity

X-ray generator
Controller
Connecting cables
Power cable
Ground bat
Fuse
Accessory kit

1
1
1*25m
1*10m
1*5m
5
1

X-ray
generator

Controller

Instruction
manual

Earthing wire 5m

Connecting cable
(10 cores) 25m

Fuse

5PC

Power cable
(2cores) 10m

Accessories
bag

S-ar putea să vă placă și