Documente Academic
Documente Profesional
Documente Cultură
2013.9.5 9:12 AM
` 1
www.lsis.com
For your safety, please read user's manual thoroughly before operating.
Contact the nearest authorized service facility for examination, repair, or adjustment.
Please contact qualified service technician when you need maintenance.
Do not disassemble or repair by yourself!
Safety Instructions
Any maintenance and inspection shall be performed by the personnel having expertise concerned.
HEAD OFFICE
Korea Gyeonggi-do Anyang-si dongan-gu
LS-ro 127 (Hogye-dong)
Tel. (82-2)2034-4887, 4873, 4918, 4148
Fax. (82-2)2034-4648
www.lsis.biz
Global Network
LSIS (Middle East) FZE
Dubai, U.A.E.
Address: LOB 19 JAFZA VIEW TOWER Room 205, Jebel Ali Freezone P.O. Box 114216, Dubai, United Arab Emirates
Tel: 971-4-886 5360 Fax: 971-4-886-5361 e-mail: dhleef@lsis.biz
CHEONG-JU PLANT
Cheong-Ju Plant #1, Song Jung Dong, Hung Duk Ku,
Cheong Ju, 361-720, Korea
2013. 09
LSIS Electric Products (E) 2004. 02/(37) 2013. 09. Printed in Korea STAFF
Page 4
Page 6
2 and 4 pole series up to 100AF
Sensitivity up to 300mA
Overcurrent protection type available
Page 8
Page 12
Metasol series
3 and 4 pole series up to 800AF Mini-contactors available
AC/DC common use coil from 150AF
Thermal (Bimetallic) and electronic type overload relays are available
CE marked and UL approved
Page 20
Page 21
Page 22
Page 24
Susol/Metasol series
2, 3 and 4 pole series up to 1600AF
Rated ambient temperature at 40 calibrated for 50 available
CE marked according to IEC standard and UL approved MCCBs are also available.
Page 32
Metasol series
2, 3 and 4 pole series up to 1200AF
CE marked according to IEC standard
Page 36
Susol/Metasol series
65, 85 and 150kA breaking capacity
High functional digital trip relays
CE marked and Marine classification
Page 42
Page 46
Page 50
Susol series
MCB
Type
BKN
BKN-c
BKN-b
Protection
Rated current
Characteristic
B, C, D curve
B, C, D curve
Poles
Breaking capacity
1pole
1pole
2~4pole
2~4pole
1A~63A
1A~63A
1A~63A
6kA at
6kA at
10kA at
10kA at
230/400VAC
400VAC
240/415VAC
415VAC
1A~63A
Standard
IEC 60898/60947-2
IEC 60898/60947-2
Approval
Type of trip
Electrical endurance
6000 operations
8000 operations
Mount
Width
Terminal
Auxiliary switch, AX
1 changeover contact
6A at 240VAC, 3A at 415VAC(AX)
6A at 230VAC, 3A at 415VAC(AL)
2A at 48VDC, 1A at 125VDC
Lug terminal
Cable capacity 2.5mm2
9mm wide
*Only for BKN
Optional
Dimension
See drawing 1
See drawing 2
Characteristic curve
See curve 1
See curve 1
(33)
(14)
45
60
68
17.8
43.8
60
68
17.8
82
65
45
37
63
82
37
45
(19)
MCB
BKH
BKP
BF-a
BF-c
BFN
Overload and short circuit Overload and short circuit Overload and short circuit Overload and short circuit
63, 80, 100A, 125A
C, D curve
B, C, D curve
1p+N
1P, 2P, 3P
1P, 2P, 3P
1pole
2~4pole
1pole
2~3pole
63A~125A
63A~125A
3A~32A
10kA at
5kA at
5A~50A
10kA at
10kA at
4.5kA at
240VAC
240VAC
10kA at
10kA at
230/400VAC
400VAC
230VAC
2.5kA at
2.5kA at
230VAC
400VAC
415VAC
415VAC
10A~100A 10A~100A
IEC 60947-2
IEC 60898
CCC, CQC CB
CCC, CQC CB
IEC 60947-2
5A~50A
IEC 60947-2
SEMKO
Thermal magnetic release Thermal magnetic release Thermal magnetic release Thermal magnetic release
6000 operations
20000 operations
10000 operations
10000 operations
See drawing 3
See drawing 4
See drawing 5
See drawing 6
See curve 1
See curve 1
See curve 2
(22)
82
60
37
45
71
(17)
(22)
40.65
5
45
60
68
8.9
17.8
RCBO
Type
RKP
Protection
Rated current, In
RKS
RKS-b
32KGRc
32KGRd
32GRhc
32GRhd
30, 100mA(non-adjustable)
0.5In
1P+N
230VAC
0.3 sec.
IEC 61009
SEMKO CB, CE
15, 30mA(non-adjustable)
0.5In
2 pole
110/220VAC
0.03 sec.
KS
-
15, 30mA(non-adjustable)
0.5In
2 pole
110/220VAC
0.03 sec.
KS
-
Electronic
Thermal-magnetic
4.5kA
Electronic
Thermal-magnetic
10kA
Electronic
Bimetallic
1.5kA
Electronic
Bimetallic
1.5kA
Conditional short
circuit capacity
Electrical endurance
Mount
Width
Terminal
Type of operation
Dimension
Characteristic curve
20000 operations
On 35mm DIN rail
35.6mm
Lug type (cable up to 10mm2)
See drawing 1
See page 5(Curve 1)
4000 operations
On 35mm DIN rail
18mm
Lug type (cable up to 10mm2)
See drawing 2 See drawing 3
See page 5(Curve 1)
6000 operations
On 35mm DIN rail / Screw
35mm
Screw clamp type (cable up to 5.5mm2)
See drawing 4
Curve 3
6000 operations
On 35mm DIN rail / Screw
33mm
Screw clamp type(cable up to 5.5mm2)
See drawing 5
Curve 4
(22)
2.5kA
2.5kA
18
16
36
62
70
80
18
18
60
82
37
45
17.5
55
13.6
(17)
23
(22)
35.6
Drawing 6: Type BS
18.5
7.9
5.8
36
18
36
56
59
70
33
20
11
16
18
18
16
36
56
59
70
17.5
11.6
17.5
18
22
45
2.4
5.8
42
33
20
11
11.6
2.4
18.5
7.9
11
21
35
59.2
59.2
42
62.3
79.5
18
5.8
2
68
82
8.9
60
68
70
28.2
38.8
18
45
(13)
45
61
74
36
Isolator
RCCB
BS32c
BS32d
RKN
Type
RKN-b
15, 30mA(non-adjustable)
0.5In
2 pole
110/220VAC
0.03 sec.
KS C 8321
KS
Electronic
Bimetallic
1.5kA
2.5kA
Electro-magnetic
N.A
-
6kA
6000 operations
DIN rail / Screw
33mm
Screw clamp type (cable up to 5.5mm2)
See drawing 6
-
6000 operations
On 35mm DIN rail
18mm
Lug type (cable up to 35mm2)
A/AC
See drawing 7
See drawing 8
-
10kA
Rated current, In
Number of poles
Rated voltage
Standard
Electrical
endurance
Mount
Width
Terminal
Dimension
BKD
40, 50, 63, 80, 100, 125A
1p, 2p, 3p, 4p
240/415VAC
IEC 60947-3
20000 operations
10000 operations
On 35mm DIN rail
17.8mm per pole
Lug type(cable up to 50)
See drawing 9
49.8
45
90
35.6
21
22
23
(10)
45
60
82
45
37
17.8
60
70
Product description
The BKS surge protective device is applied to the alternating current 50/60Hz power system and provides the protection from
the surge overvoltage of an electric system.
Moreover, it is the protection element (MOV) replacement type and is the product with convenience and economic efficiency.
If the protective device is normal, the display becomes green.
The display becomes red after operation (abnormal or after an accident).
Product rating
SPD according to IEC
Number of positions
BKS-A
BKS-B
Class
Class
[Pole]
BKS-C
BKS-D
BKS-E
Class
Class
Class
1, 2, 3, 4
Nominal voltage, Un
AC
[V]
AC
[V]
320
320
320
420
460
[kV]
1.2
1.2
1.5
2.0
2.5
10
20
30
35
10
20
40
60
70
8/20
Response time, tA
[ns]
< 25ns
[]
-40 ~ +80
Operating frequency
[Hz]
50 / 60 Hz
Mounting on
Din-rail 35mm
[mm2]
Degree of protection
IP20
Modes of protection
L-G, N-G
Common bar
External dimension
1P
2P
3P
4P
* A separate fuse can be installed depending on the side conditions. (The fuse should be purchased separately is not supplied by LS.)
Product description
The SP series surge protective device is applied to the alternating current 50/60Hz, 220V/380V power system and provides the
protection from the surge overvoltage of an electric system.
Moreover, the protection module, disconnectable device (fuse), and fastened power and ground wires are organized into the allin-one steel cabinet with convenient installation and stability.
If the protective device is normal, the display becomes green.
The display becomes red after operation (abnormal or after an accident).
Product rating
- Single phase 2W+G (SPL)
SPL-110S
SPD according to IEC
Number of positions
Nominal voltage, Un
Max. continuous operating voltage, Uc
Voltage protection level, Up
Nominal discharge current, .In 8/20
Maximum discharge current, Imax 8/20
Response time, tA
Operating temperature range
Operating frequency
Mounting on
Degree of protection
Modes of protection
Operation status indication
[Pole]
AC
[V]
AC
[V]
[kV]
[kA, per mode]
[kA, per mode]
SPL-220S
SPL-220S
Class
2W+G
110/220
320
1.5
10
20
[ns]
[]
[Hz]
Class /
2W+G
220
320
1.5
20
40
40
80
< 5ns
-40 ~ +70
50 / 60 Hz
Screw
IP20
L-N, L-G, N-G
Normal operation : Green, Abnormal/After an accident : Red
Product rating
-Three phase 3W+G (SPT) AC 380V
SPT-380S
SPD according to IEC
Number of positions
[Pole]
Nominal voltage, Un
AC
[V]
Max. continuous operating voltage, Uc
AC
[V]
Voltage protection level, Up
[kV]
Lightning impulse current, .Iimp 10/350 [kA, per mode]
Nominal discharge current, .In 8/20 [kA, per mode]
Maximum discharge current, Imax 8/20 [kA, per mode]
Response time, tA
[ns]
Operating temperature range
[]
Operating frequency
[Hz]
Mounting on
Degree of protection
Modes of protection
Operation status indication
10
Class /
Class
3W+G
3P3W 380
320
2.0
20
40
40
80
20
60
120
< 5ns
-40 ~ +70
50 / 60 Hz
Screw
IP20
L-G
Normal operation : Green, Abnormal/After an accident : Red
40
80
160
Product rating
-Three phase 3W+G (SPT) AC 440V
SPT-440S
SPD according to IEC
Number of positions
[Pole]
Nominal voltage, Un
AC
[V]
Max. continuous operating voltage, Uc
AC
[V]
Voltage protection level, Up
[kV]
Lightning impulse current, .Iimp 10/350 [kA, per mode]
Nominal discharge current, .In 8/20 [kA, per mode]
Maximum discharge current, Imax 8/20 [kA, per mode]
Response time, tA
[ns]
Operating temperature range
Operating frequency
Mounting on
Degree of protection
Modes of protection
Operation status indication
Class /
Class
3W+G
3P3W 440
320
2.0
20
40
40
80
20
60
120
40
80
160
< 5ns
-40 ~ +70
50 / 60 Hz
Screw
IP20
L-G
Normal operation : Green, Abnormal/After an accident : Red
[]
[Hz]
Product rating
-Three phase 4W+G (SPY)
SPY-220S
SPD according to IEC
Number of positions
[Pole]
Nominal voltage, Un
AC
[V]
Max. continuous operating voltage, Uc
AC
[V]
Voltage protection level, Up
[kV]
Lightning impulse current, .Iimp 10/350 [kA, per mode]
Nominal discharge current, .In 8/20 [kA, per mode]
Maximum discharge current, Imax 8/20 [kA, per mode]
Response time, tA
[ns]
Operating temperature range
[]
Operating frequency
[Hz]
Mounting on
Degree of protection
Modes of protection
Operation status indication
Class /
Class
4W+G
3P4W 380/220
320
2.0
20
40
40
80
20
60
120
40, 50, 60
80, 100, 120
160, 200, 240
< 5ns
-40 ~ +70
50 / 60 Hz
Screw
IP20
L-G
Normal operation : Green, Abnormal/After an accident : Red
11
MC type
Magnetic Contactors
18AF
Frame size
Type
screws clamp terminals
Number of poles
Rated operational voltage, Ue
Rated insulation voltage, Ui
Rated frequency
Rated impulse withstand voltage, Uimp
Maximum operating rate in operating cycles per hour(AC3)
Durability
Mechanical
Electrical
Current
AC-1, Thermal current
A
and
AC-3
200/240V
kW
power
A
380/440V
kW
A
500/550V
kW
A
690V
kW
A
1000V
kW
A
Rated Short-time
1s
A
withstand current
10s
A
(IEC 60947)
30s
A
1min
A
3min
A
10min
A
15min
A
UL rating
Continuous current
A
(50/60Hz)
Single
110~120V
HP
phase
220~240V
HP
200~208V
HP
Three
220~240V
HP
phase
440~480V
HP
550~600V
HP
NEMA size
Size
AC
Weight
kg
H control
and
Size(WHD) mm
weight
DC
Weight
kg
D
W
control Size(WHD) mm
Auxiliary(standard)
Auxiliary
Side mount
Front mount
MC-6a
25
2.2
9
3
7
3
6
3
4
210
105
70
61
40
30
25
25
0.5
1.5
2
3
5
7.5
00
MC-9a
MC-12a
3pole
690V
690V
50/60Hz
6kV
1800 operations per hour
15 mil. operations
2.5 mil. operations
25
25
2.5
3.5
11
13
4
5.5
9
12
4
7.5
7
12
4
7.5
5
9
250
280
110
120
70
80
61
61
45
47
30
30
26
28
25
25
0.5
0.75
1.5
2
2
3
3
5
5
7.5
7.5
10
00
0
0.33
4573.580.4
0.4
4573.596.6
1NO or 1NC
UA-1
UA-2, UA-4
22AF
MC-18a
MC-9b
32
4.5
18
7.5
18
7.5
13
7.5
9
300
130
85
70
50
40
40
32
1
3
5
7.5
10
15
1
25
2.5
11
4
9
4
7
4
6
250
110
70
61
45
30
26
25
0.5
1.5
2
3
5
7.5
00
MC-12b
MC-18b
3pole
690V
690V
50/60Hz
6kV
1800 operations per hour
15 mil. operations
2.5 mil. operations
25
40
3.5
4.5
13
18
5.5
7.5
12
18
7.5
7.5
12
13
7.5
7.5
9
9
280
300
120
154
80
100
61
84
50
60
30
40
28
40
25
40
0.75
1
2
3
3
5
5
7.5
7.5
10
10
15
00
1
0.34
4573.587.4
0.41
4573.5103.6
1NO1NC
UA-1
UA-2, UA-4
MT type
Thermal Overload Relays
Type
Screws clamp terminals
Rated operational voltage, Ue
Rated insulation voltage, Ui
Rated impulse withstand voltage, Uimp
Trip class
Setting range
Size
Weight
kg
and
H
weight
Size(WHD) mm
D
W
* The safety cover of magnetic contactor and thermal overload relay is optional.
12
MT-12/
690V
690V
6kV
10A, 20
0.1~18A
MT-32/
690V
690V
6kV
10A, 20
0.1~40A
0.1
0.17
4573.263.7
457590
MC-22b
40
5.5
22
11
22
15
20
15
18
400
186
130
90
60
50
45
40
2
3
7.5
10
15
20
40AF
MC-32a
65AF
MC-40a
MC-50a
100AF
MC-65a
MC-75a
3pole
690V
1000V
50/60Hz
8kV
1800 operations per hour
12 mil. operations
2 mil. operations
50
60
7.5
11
32
40
15
18.5
32
40
18.5
22
28
32
18.5
22
20
23
22
22
17
17
600
700
260
300
160
190
100
120
70
80
55
65
50
60
50
60
2
3
5
7.5
7.5
15
10
15
20
30
25
30
1P
2
0.4
458390
0.6
45 83117.1
2NO2NC
UA-1
UA-2, UA-4
3pole
690V
1000V
50/60Hz
8kV
1200 operations per hour
12 mil. operations
2 mil. operations
70
100
15
18.5
55
65
22
30
50
65
30
33
43
60
30
33
28
35
30
33
23
26
1000
1050
550
700
330
380
250
270
150
200
90
120
87
100
70
100
3
5
10
15
20
25
25
30
40
50
50
60
0.9
55106119
1.2
55106146.4
2NO2NC
UA-1
UA-2, UA-4
MC-85a
3pole
690V
1000V
50/60Hz
8kV
1200 operations per hour
12 mil. operations
2 mil. operations
135
25
85
45
85
45
75
45
45
45
33
1200
800
450
350
270
170
150
135
7.5
15
30
40
60
75
3
1.6
70140135.8
2.6
70140172.3
2NO2NC
UA-1
UA-2, UA-4
MT-32/
690V
690V
6kV
10A, 20
0.1~40A
MT-63/
690V
690V
6kV
10A, 20
4~65A
MT-95/
690V
690V
6kV
10A, 20
7~100A
0.17
0.31/0.33
0.48/0.5
457590
5581100
7097110
110
22
75
37
75
37
64
37
42
37
28
1100
750
400
300
220
140
114
110
5
15
25
30
50
60
MC-100a
160
30
105
55
105
55
85
55
65
45
33
1320
900
500
400
270
180
160
160
10
20
30
40
75
75
13
MC type
Magnetic Contactors
150AF
Frame size
Type
screws clamp terminals
Number of poles
Rated operational voltage, Ue
Rated insulation voltage, Ui
Rated frequency
Rated impulse withstand voltage, Uimp
Maximum operating rate in operating cycles per hour(AC3)
Durability
Mechanical
Electrical
Current
AC-1, Thermal current
A
and
AC-3
200/240V
kW
power
A
380/440V
kW
A
500/550V
kW
A
690V
kW
A
1000V
kW
A
Rated Short-time
1s
A
withstand current
10s
A
(IEC 60947)
30s
A
1min
A
3min
A
10min
A
15min
A
UL rating
Continuous current
A
(50/60Hz)
Single
110~120V
HP
phase
220~240V
HP
200~208V
HP
Three
220~240V
HP
phase
440~480V
HP
550~600V
HP
NEMA size
Size
AC
Weight
kg
H control
and
Size(WHD) mm
weight
DC
Weight
kg
D
control Size(WHD) mm
W
Auxiliary(standard)
Auxiliary
Side mount
Front mount
MC-130a
225AF
MC-150a
MC-185a
MC-225a
3pole
690V
1000V
50/60Hz
8kV
1200 operations per hour
5 mil. operations
1 mil. operations
160
210
37
45
130
150
60
75
130
150
60
70
90
100
55
55
60
60
75
90
53
65
1350
1800
950
1200
700
800
550
600
350
450
200
300
175
280
160
210
10
15
20
25
40
40
40
50
75
100
75
75
4
3pole
690V
1000V
50/60Hz
8kV
1200 operations per hour
5 mil. operations
1 mil. operations
230
275
55
75
185
225
90
132
185
225
110
132
180
200
110
140
120
150
132
140
90
100
2000
2500
1500
1700
1000
1200
800
1000
520
700
350
500
320
400
230
275
15
15
30
40
60
60
60
75
125
150
125
150
2.4
95158130.3
5.4
138203185.1
2NO2NC
UA-1
UA-2, UA-4
2NO2NC
AU-100, AU-100E (Max.4NO4NC)
-
MT-150/
690V
690V
6kV
10A, 20
34~150A
MT-225/
690V
690V
6kV
10A, 20
65~240A
0.67
2.5
95109113
147141184
MT type
Thermal Overload Relays
Type
Screws clamp terminals
Rated operational voltage, Ue
Rated insulation voltage, Ui
Rated impulse withstand voltage, Uimp
Trip class
Setting range
Size
Weight
kg
and
H
weight
Size(WHD) mm
D
W
* The safety cover of magnetic contactor and thermal overload relay is optional.
14
400AF
MC-265a
300
80
265
147
265
147
225
160
185
147
105
3500
2400
1500
1100
800
600
500
300
75
100
200
200
5
MC-330a
3pole
690V
1000V
50/60Hz
8kV
1200 operations per hour
5 mil. operations
1 mil. operations
350
90
330
160
330
160
250
200
220
160
115
4000
3000
2500
1700
1000
620
553
350
100
100
200
200
800AF
MC-400a
MC-500a
580
147
500
265
500
265
400
300
380
280
220
6000
5050
4400
3400
2000
1400
1100
580
150
200
400
400
6
MC-630a
3pole
690V
1000V
50/60Hz
8kV
1200 operations per hour
2.5 mil. operations
0.5 mil. operations
660
190
630
330
630
330
500
400
420
355
262
7000
6400
4500
3500
2200
1550
1300
660
200
250
500
500
9.2
163243204.4
22.4
285312245.3
2NO2NC
AU-100, AU-100E (Max.4NO4NC)
-
2NO2NC
AU-100, AU-100E (Max.4NO4NC)
-
MT-400/
690V
690V
6kV
10A, 20
85~400A
MT-800/
690V
690V
6kV
10A, 20
200~800A
2.6
11.5
151171198
360530212
MC-800a
900
220
800
440
800
500
720
500
630
400
288
7500
7000
4900
3800
2500
1550
1300
900
200
300
600
600
7
15
MC type
Magnetic Contactors
18AF
Frame size
Type
MC-6a/4
MC-9a/4
MC-12a/4
MC-18a/4
Number of poles
4pole
690V
690V
Rated frequency
50/60Hz
6kV
Mechanical
15 mil. Operations
Electrical
Current
Thermal current
and
AC-1
200/240V
Power
380/400V
500/550V
690V
25
25
25
40
kW
15
25
25
25
40
kW
17
17
17
27
25
25
25
40
kW
21
21
21
35
25
25
25
40
kW
27
27
27
44
25
25
25
40
25
25
25
32
UL rating
Continuous current
(50/60Hz)
Single
110~120V
HP
0.5
0.5
0.75
Phase
220~240V
HP
1.5
1.5
200~208V
HP
Three
220~240V
HP
7.5
Phase
440~480V
HP
7.5
10
550~600V
HP
7.5
7.5
10
15
AC
Weight
Size
and
weight
W
Control
Size(WHD)
DC
Weight
Control
Size(WHD)
16
0.33
mm
4573.5 79
kg
0.5
mm
4573.5110.7
Auxiliary(standard)
Auxiliary
kg
Side Mount
UA-1
Front Mount
AU-2, AU-4
40AF
22AF
MC-22a/4
MC-32a/4
85AF
MC-40a/4
MC-50a/4
MC-65a/4
MC-75a/4
4pole
4pole
4pole
690V
690V
690V
690V
690V
1000V
50/60Hz
50/60Hz
50/60Hz
6kV
6kV
8kV
15 mil. Operations
15 mil. Operations
12 mil. Operations
1 mil. Operations
1 mil. Operations
MC-85a/4
1 mil. Operations
40
50
60
80
100
110
15
18
22
30
37
41
51
40
50
60
80
100
110
135
135
27
35
42
56
70
76
95
40
50
60
80
100
110
135
35
43
52
70
88
97
120
40
50
60
80
100
110
135
44
55
66
88
110
120
150
40
50
60
80
100
110
135
32
45
50
70
80
90
100
7.5
7.5
10
15
15
7.5
7.5
10
10
15
20
25
7.5
10
10
15
20
25
30
10
20
25
30
40
50
50
15
20
25
30
40
50
50
0.4
0.59
1.2
47.28086.8
5983.594.5
91123.5117.8
0.5
0.7
1.29
47.280113.2
5983.5121
91123.5117.8
AU-1
AU-1
AU-1
AU-2, AU-4
AU-2, AU-4
AU-2, AU-4
17
MC type
Magnetic Contactors
225AF
Frame size
Type
MC-100a/4
MC-130a/4
MC-150a/4
MC-185a/4
MC-225a/4
Number of poles
4pole
690V
1000V
Rated frequency
50/60Hz
8kV
Mechanical
5 mil. Operations
Electrical
Current
Thermal current
and
AC-1
200/240V
Power
380/400V
500/550V
690V
160
165
250
300
330
kW
57
60
76
87
100
150
155
200
230
260
kW
106
110
142
165
185
150
155
200
230
260
kW
132
137
180
205
230
150
155
200
230
260
kW
165
170
225
255
290
150
155
200
230
260
160
160
210
230
275
7.5
10
15
15
15
UL rating
Continuous current
(50/60Hz)
Single
110~120V
HP
Phase
220~240V
HP
15
20
25
30
40
200~208V
HP
30
40
40
60
60
Size
and
weight
W
Three
220~240V
HP
30
40
50
60
75
Phase
440~480V
HP
60
75
100
125
150
550~600V
HP
60
75
100
125
150
AC
Weight
Control
Size(WHD)
DC
Weight
Control
Size(WHD)
5.6
kg
175203185
mm
2a2b
Side Mount
AU-100 / AU-100E
Front Mount
18
mm
Auxiliary(standard)
Auxiliary
kg
400AF
MC-265a/4
MC-330a/4
800AF
MC-400a/4
MC-500a/4
MC-630a/4
4pole
4pole
690V
690V
1000V
1000V
50/60Hz
50/60Hz
8kV
8kV
MC-800a/4
360
420
500
630
750
900
115
135
160
245
255
310
300
350
420
630
660
800
215
250
300
450
470
570
300
350
420
630
660
800
265
315
375
560
590
710
300
350
420
630
660
800
335
390
470
710
740
900
300
350
420
630
660
800
300
350
450
580
660
900
75
100
125
150
200
200
100
125
150
200
250
300
200
250
300
400
500
600 *
200
250
300
400
500
600 **
9.9
26.3
206243205
346310 244
2a2b
2a2b
AU-100
AU-100
19
Mini contactors
6 to 16A
Mini contactors
Frame size
Fast-on type
6A
9A
12A
16A
GMC-6M
GMC-9M
GMC-12M
GMC-16M
AC coil
DC coil
GMD-6M
GMD-9M
GMD-12M
GMD-16M
Fast-on type
AC coil
GMC-6MF
GMC-9MF
GMC-12MF
GMC-16MF
DC coil
GMD-6MF
GMD-9MF
GMD-12MF
GMD-16MF
AC coil
GMC-6MC
GMC-9MC
GMC-12MC
GMC-16MC
DC coil
GMD-6MC
GMD-9MC
GMD-12MC
GMD-16MC
AC coil
GMC-6MP
GMC-9MP
GMC-12MP
GMC-16MP
DC coil
GMD-6MP
GMD-9MP
GMD-12MP
Ratings / IEC60947-4
kW
AC1
AC3
kW
20
GMD-16MP
A
kW
20
A
20
200/240V
1.5
2.2
12
15
380/440V
2.2
5.5
12
7.5
16
500/550V
3.7
5.5
690V
hp
hp
hp
hp
Ratings / UL508
1/2
1*
1.5
2**
240V
1.5
480V
7.5 * * *
600V
7.5
00
00
120V
230V/240V
three phase
kW
20
continuous current
single phase
00
Fast-on type
AU-2M
AU-2MF
AU-2MC
AU-4M
AU-4MF
AU-4MC
AU-1M
AU-1MF
AU-1MP
AU-1MC
Note) * = 1/2 for cage clamp type, ** = 1.5hp for cage clamp type, *** = 5hp for cage clamp type
16AF : not approved from UL
Overload Relays
Setting
ranges (A)
Bimetallic style
Type GT
GT-12M
Differential
20
0.1 - 0.16
0.16 - 0.25
0.25 - 0.4
0.4 - 0.63
0.63 - 1
1 - 1.6
1.6 - 2.5
2.5 - 4
4-6
5-8
6-9
7 - 10
9 - 13
12 - 16
GTK-12M
Non-differential (3-heater)
GTH-12M/3
Non-differential (2-heater)
GTH-12M
Base for
separate mount
DMP-S/Sa
Model No.
DMP-T/Ta
DMP06-S/Sa
Wiring
DMP60-S/Sa
Screw type
Panel mount
Unit or Extension
Operation time
Over current
Tunnel type
Note1)
Phase failure
3 sec.
Reverse phase
Asymmetry
5 sec.
Stall
5 sec.
Lock
Under current
3 sec.
Ground fault
Short circuit
Note2)
Alarm
Within 50ms
Variable (60~110% of the setting current)
220~240V
(kW)
380~440V
0.5~6
5~60
0.5~6
5~60
0.09~0.75
1.1~11
0.09~0.75
1.1~11
0.12~1.5
2.2~22
0.09~1.5
2.2~22
Time setting
Definite
Delay in starting
0~60sec
range (sec)
time
Delay in operating
0~30sec
Inverse time
0~60sec
Reset
Manual reset
Tolerance
Current
5%
Time
5% (or0.5sec)
Operating power
Voltage
AC 190~250V
Note3)
Frequency
60Hz (50Hz)
OL
1a1b
AL
1a
Insulation resistance
2.5kV/5min
Environment
Temperature
Operation
-25~70
Storage
-30~80
Humidity
Display
Mounting type
DMP06-T/Ta
Protection
Aux. contact
DMP06-T/Ta
Bar-Graph
Note1) In extension type, the digital EMPR is calibrated with combining the display past and main body so,
please cautious not to combine the display part and main body with different part No.
Note2) Instantaneous short circuit protection is optional
Note3) Operational voltage of AC 110V and 50Hz is optional
21
Frame
Type
Number of poles
Rated operational voltage (Ue)
Rated frequency
Rated insulation voltage (Ui)
Rated impulse voltage (Uimp)
Utilization category
IEC 60 947-2 (Breaker)
IEC 60 947-4 (Motor starter)
Mechanical endurance (Operating)
Electrical endurance (Cycles)
Max operating frequency per hour (Ope./h)
Temperature compensation (Operation)
Instantaneous short circuit release
Overload protection
Phase failure function
Trip indicating function
Test function
Dimension(WHD)
Weight (g)
Rated
Thermal release
Rated
breaking
Adjustment
operational
range
capacity
current (Ie)
(A)
(kA)
0.1~0.16
0.16
0.16~0.25
0.25
0.25~0.4
0.4
0.4~0.63
0.63
0.63~1
1
1~1.6
1.6
1.6~2.5
2.5
2.5~4
4
4~6
6
5~8
8
6~10
10
9~13
13
11~17
17
14~22
22
18~26
26
22~32
32
28~40
40
34~50
50
45~63
63
55~75
75
70~90
90
80~100
100
22
32AF
MMS-32S
Standard
Toggle
3
Up to 690V
50/60 Hz
690V
6kV
Cat. A
AC 3
100,000
100,000
25
-20 ~ +60
13 Ie max.
4510554.4
320
220V
240V
230V
415V
400V
460V
440V
MMS-32H
MMS-32HI
High breaking
Rotary
3
Up to 690V
50/60 Hz
690V
6kV
Cat. A
AC 3
100,000
100,000
25
-20 ~ +60
13 Ie max.
4510560.3
360
525V
500V
690V
600V
220V
240V
230V
415V
400V
460V
440V
525V
500V
690V
600V
Icu
Ics
Icu
Ics
Icu
Ics
Icu
Ics
Icu
Ics
Icu
Ics
Icu
Ics
Icu
Ics
Icu
Ics
Icu
Ics
100
100
100
100
100
100
100
100
100
100
100
100
50
40
40
30
-
100
100
100
100
100
100
100
100
100
100
100
100
38
30
30
22
-
100
100
100
100
100
100
100
100
100
100
50
50
20
15
15
15
-
100
100
100
100
100
100
100
100
100
100
38
38
15
11
11
11
-
100
100
100
100
100
100
100
50
15
15
15
10
10
8
8
6
-
100
100
100
100
100
100
100
38
11
11
11
8
8
6
6
4
-
100
100
100
100
100
100
50
15
10
10
6
6
6
6
6
5
-
100
100
100
100
100
100
38
11
8
8
5
5
5
5
5
4
-
100
100
100
100
100
3
3
3
3
3
3
3
3
3
3
3
-
100
100
100
100
100
3
3
3
3
3
3
3
3
3
3
3
-
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
-
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
-
100
100
100
100
100
100
100
100
100
100
100
100
50
50
50
50
-
100
100
100
100
100
100
100
100
100
100
100
100
38
38
38
38
-
100
100
100
100
100
100
100
100
100
50
50
50
20
20
20
20
-
100
100
100
100
100
100
100
100
100
38
38
38
15
15
15
15
-
100
100
100
100
100
100
100
100
100
50
50
42
10
10
10
10
-
100
100
100
100
100
100
100
100
100
38
38
32
8
8
8
8
-
100
100
100
100
100
100
8
8
6
6
6
6
4
4
4
4
-
100
100
100
100
100
100
8
8
6
6
6
6
4
4
4
4
-
100AF
63AF
MMS-63S
Standard
Rotary
3
Up to 690V
50/60 Hz
1,000V
8kV
Cat. A
AC 3
50,000
25,000
25
-20 ~ +60
13 Ie max.
55125112.3
1,000
220V
240V
230V
415V
400V
460V
440V
MMS-63H
MMS-63HI
High breaking
Rotary
3
Up to 690V
50/60 Hz
1,000V
8kV
Cat. A
AC 3
50,000
25,000
25
-20 ~ +60
13 Ie max.
55125112.3
1,000
525V
500V
690V
600V
Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics
- - - - - - - - - - 100 100
100 100
100 100
50 38
50 38
50 38
50 38
50 38
50 38
-
- - - - - - - - - - 100 100
50 38
25 19
25 19
25 19
25 19
25 19
25 19
25 19
- - - -
- - - - - - - - - - - - - - - - - - - - 15 12 10
10 8 6
10 8 6
10 8 6
10 8 6
10 8 6
10 8 6
10 8 6
10 8 6
- - - - - - -
8
5
5
5
5
5
5
5
5
-
4
4
4
4
4
4
4
4
4
-
3
3
3
3
3
3
3
3
3
-
220V
240V
230V
415V
400V
460V
440V
525V
500V
MMS-100S
Standard
Rotary
3
Up to 690V
50/60 Hz
1,000V
8kV
Cat. A
AC 3
50,000
25,000
25
-20 ~ +60
13 Ie max.
70165138
2,200
690V
600V
Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics
50
50
50
50
35
35
35
35
35
-
38
38
38
38
27
27
27
27
27
-
- - - - - - - - - - 50 38
42 32
12 9
12 9
12 9
10 8
10 8
10 8
10 8
- - - -
6
6
5
5
5
5
5
5
5
-
5
5
5
5
5
5
5
5
5
-
220V
240V
230V
415V
400V
460V
440V
MMS-100H
MMS-100HI
High breaking
Rotary
3
Up to 690V
50/60 Hz
1,000V
8kV
Cat. A
AC 3
50,000
25,000
25
-20 ~ +60
13 Ie max.
70165138
2,200
525V
500V
690V
600V
Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics
- - - - - - - - - - - - 100 100
100 100
100 100
100 100
100 100
100 100
100 100
100 100
100 100
100 100
50
50
50
50
50
50
50
50
50
50
38
38
38
38
38
38
38
38
38
38
40
40
40
40
40
40
40
40
40
40
30
30
30
30
30
30
30
30
30
30
25
25
25
15
15
12
12
8
8
8
19
19
19
11
11
9
9
6
6
6
10
10
10
10
6
6
6
5
5
5
8
8
8
8
5
5
5
4
4
4
220V
240V
230V
415V
400V
460V
440V
525V
500V
690V
600V
Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics
50
50
50
50
50
50
50
50
50
50
38
38
38
38
38
38
38
38
38
38
35
35
35
25
20
15
15
12
12
12
27
27
27
19
15
11
11
9
9
9
12
12
12
12
12
10
8
6
6
6
9
9
9
9
9
8
6
6
6
6
23
Frame size
Rated current, In
No. of poles
Rated operational
AC
voltage, Ue
DC
Rated impulse withstand voltage, Uimp
Rated insulation voltage, Ui [V]
Rated ultimate short-circuit breaking capacity, Icu
AC 50/60Hz
220/240V
[kA]
DC
TE160
TD100
100
160
100
[A]
16~100
[V]
[V]
[kV]
3,4
690
500
8
750
100,125,160
3,4
690
500
8
750
1, 2, 3, 4
240(1P), 690
250(1P), 500
8
750
N
L
N
H
L
30(1P) 50(1P)
85
100
200
200
85
100
50
85
150
50
85
150
50
70
130
50
70
130
30
50
65
30
50
65
5
8
10
5
8
10
16(1P) 25(1P)
42
65
100
100
42
65
42
65
100
42
65
100
100% 100% 100% 100% 100% 100%
50
85
50
85
37
25
18
6
50
37
25
8
37
25
18
6
50
37
25
8
250V
[kA]
37
50
37
50
37
100%
50
100%
37
100%
50
100%
105
187
105
187
187
220
440
77.7
52.5
36
9.2
105
77.7
52.5
13.6
77.7
52.5
36
9.2
105
77.7
52.5
13.6
105
105
63
8
330
286
143
17
[kA]
[kA]
[kA]
[kA]
Category of utilization
Isolation behavior
Trip unit (release)
Thermal-Magnetic
fixed-thermal, fixed-magnetic
FTU
adjustable-thermal, fixed-magnetic
FMU
adjustable-thermal, adjustable-magnetic
ATU
magnetic only
MTU
Electronic
LSI
ETS
LSI
ETM
Option Earth-fault protection, Ig
Zone selective interlocking, ZSI
Ammeter
Communication
Earth-leakage protection module
Connection
fixed
front-connection
rear-connection
plug-in
front-connection
rear-connection
Mechanical life
[operations]
Electrical life @ 415 V AC
[operations]
Basic dimensions, WHD 1-pole
[mm]
(front connection)
3-pole
[mm]
4-pole
[mm]
Weight
1-pole
[kg]
(front connection)
3-pole
[kg]
4-pole
[kg]
Reference standard
187
154
105
14
A
25000
10000
7613082
10113082
1.05
1.35
IEC60947-2
25000
10000
7613082
10113082
1.05
1.35
IEC60947-2
160
1P: 16, 20, 25, 32, 40, 50,
63, 80,100,125, 160
2, 3P: 100, 125, 160
2, 3, 4
690
500
8
750
H
[kA]
[kA]
[kA]
[kA]
380/415V
440/460V
480/500V
660/690V
24
TD160
380/415V
440/460V
480/500V
660/690V
500V(2poles in series)
[kA]
Rated service breaking capacity, Ics
[%Icu]
Rated short-circuit making capacity Icm
AC 50/60Hz
220/240V
[kA]
TE100
[AF]
25000
10000
9014086
12014086
1.5
1.8
IEC60947-2
105(1P) 105(1P)
440
187
220
105
187
330
105
154
286
63
105
143
8
14
17
A
25000
10000
3514086
9014086
12014086
0.57
1.5
1.8
IEC60947-2
TS100
TS160
TS250
TS400
TS630
TS800
100
160
250
400
630
800
300, 400
500, 630
700, 800
2, 3, 4
690
500
8
750
H
2, 3, 4
690
500
8
750
H
2, 3, 4
690
500
8
750
H
2, 3, 4
690
500
8
750
H
100
50
50
42
10
120
200
100
85
70
65
15
150
130
85
20
50
50
42
10
50
85
100
50
100%
85
100%
100
100%
220
264
105
105
88
17
187
154
143
30
A
2, 3, 4
690
500
8
750
H
2, 3, 4
690
500
8
750
H
120
200
100
85
70
65
15
150
130
85
20
50
50
42
10
120
200
100
120
200
100
120
200
100
120
200
85
70
65
15
150
130
85
20
65
65
42
10
85
85
65
20
150
130
85
35
65
65
42
10
85
85
65
20
150
130
85
35
65
65
42
10
100
100
85
20
150
130
100
35
50
85
100
50
100%
85
100%
100
100%
50
85
100
50
85
100
50
85
100
50
85
100
50
100%
85
100%
100
100%
50
100%
85
100%
100
100%
50
100%
85
100%
100
100%
50
100%
85
100%
100
100%
440
220
264
440
220
264
440
220
264
440
220
264
440
220
264
440
330
286
187
40
105
105
88
17
187
154
143
30
A
330
286
187
40
105
105
88
17
187
154
143
30
A
330
286
187
40
143
143
88
17
187
187
143
40
A
330
286
187
74
143
143
88
17
187
187
143
40
A
330
286
187
74
143
143
88
17
220
220
187
40
A
330
286
220
74
25000
10000
10516086
14016086
2
2.6
IEC60947-2
25000
10000
10516086
14016086
2
2.6
IEC60947-2
25000
10000
10516086
14016086
2
2.6
IEC60947-2
20000
6000
140260110
186.5260110
5.4
7.2
IEC60947-2
20000
6000
140260110
186.5260110
5.4
7.2
IEC60947-2
10000
3000
210320135
280320135
15.1
19.6
IEC60947-2
Amb. Temp.
TD160
TS250
TS630
TS800
TD160
TS250
TS630
TS800
-5C
122.5%
122.5%
110.0%
110.0%
122.0%
122.0%
122.2%
112.2%
0C
120.0%
120.0%
109.0%
109.0%
120.0%
120.0%
112.0%
112.0%
10C
115.0%
115.0%
107.0%
107.0%
116.0%
116.0%
110.0%
110.0%
20C
110.0%
110.0%
105.0%
105.0%
112.0%
112.0%
108.0%
108.0%
25C
107.5%
107.5%
104.0%
104.0%
110.0%
110.0%
107.0%
107.0%
30C
105.0%
105.0%
103.0%
103.0%
108.0%
108.0%
106.0%
106.0%
35C
102.5%
102.5%
101.5%
101.5%
106.0%
106.0%
104.5%
104.5%
40C
100.0%
100.0%
100.0%
100.0%
104.0%
104.0%
103.0%
103.0%
45C
97.5%
97.5%
98.5%
98.5%
102.0%
102.0%
101.5%
101.5%
50C
95.0%
95.0%
97.0%
97.0%
100.0%
100.0%
100.0%
100.0%
25
Type
TS1000
TS1250
TS1600
TS1000
TS1250
TS1600
1000
1250
1600
Ampere frame
Pole
3, 4
Rated current,(A)
In
Ui
Uimp
Ue
3, 4
3, 4
-5~40C
800, 1000
1250
1600
50C
800, 1000
1250
1560
65C
800, 1000
1240
1420
1000
1000
1000
AC50/60Hz
690
690
690
DC
Rated short-circuit breaking capacity
IEC60947-2
220/240V
55
75
200
55
75
55
75
AC50/60Hz
380/415V
50
70
150
50
70
50
70
440/460V
50
65
130
50
65
50
65
480/500V
40
50
100
40
50
40
50
660/690V
35
45
35
45
35
45
250V 2P
500V 2P
750V 3P
100%
75%
100%
100%
75%
100%
75%
(sym)
DC
Rated service
%Icu
AC50/60Hz
1s
25
3s
kA peak
50
25
25
50
50
30
Isolation
Category
B
Mechanical life (operations)
(Life cycle)
12
Electrical life
10000
4000
10000
10000
440V
In/2
6000
4000
5000
5000
In
5000
3000
4000
2000
690V
In/2
4000
3000
3000
2000
In
2000
2000
2000
1000
(operations)
Pollution degree
Dimension (mm)
3-pole
327210152.5
(HWD)
4-pole
327280152.5
Weight (kg)
3-pole
13
4-pole
16.8
26
Overview
Classification
N type
A type
P type
S type
Externals
Current
protection
L / S / I / G / Thermal
Other
protection
L / S / I / G / Thermal
ZSI(Protective coordination)
Earth leakage (Option)
Current (R / S / T / N)
Measurement
function
Fine adjustment
Digital Output
IDMTL setting
Communication
Power supply
RTC timer
LED for
trip info.
Self Power
-Power source
works over 25% of
current of In (one pole)
Available
Long time delay
Short time delay/Instantaneous
Ground fault
Fault recording
Event recording
Operating
Reset button
button
3DO (Fixed)
L, S/I, G Alarm
Modbus/RS-485
Profibus-DP
Self Power
- Power source works over
25% of current of In (one pole)
- External power source are
required for comm.
AC/DC 100~250V
DC 24~60V
Available
N type
10 records
(Fault/Current/Date and Time)
Reset, Menu
Up/Down, Left/Right, Enter
L / S / I / G / Thermal(Continuous)
ZSI(Protective coordination)
Earth leakage(Option)
Over/Under current
Over/Under frequency
Unbalance(Voltage/Current)
Reverse power
3 Phase Voltage/Current
RMS/Vector
Power(P, Q, S), PF(3-Phase)
Energy(Positive/Negative)
Frequency, Demand
P type
P type
3 Phase Voltage/Current
RMS/Vector
Power(P, Q, S), PF(3-Phase)
Energy(Positive/Negative)
Frequency, Demand
Voltage/Current harmonics
(1st~63th)
3 Phase Waveforms
THD, TDD, K-Factor
P type
P type
P type
P type
Modbus / RS-485
Profibus-DP
AC/DC 100~250V
DC 24~60V
Available
N type
256 records
(Fault/Current/Date and Time)
256 records(Content, Status, Date)
A type
256 records
Last fault wave recording (3 Phase)
P type
A type
27
Frame Size(AF)
Type
Type and Pole
Rated current, In
30
60
50
S-Type
N-Type
S-Type
H-Type
N-Type
S-Type
2 pole
ABS32c
ABN52c
ABS52c
ABH52c
ABN62c
ABS62c
3 pole
ABS33c
ABN53c
ABS53c
ABH53c
ABN63c
ABS63c
4 pole
ABS34c
ABN54c
ABS54c
ABH54c
ABN64c
ABS64c
(3, 5, 10)
15, 20, 30
Rated operational
AC(V)
690
690
690
690
690
690
voltage, Ue
DC(V)
500
500
500
500
500
500
750
750
750
750
750
750
kV
DC
690V
2.5
2.5
10
2.5
480/500V
7.5
7.5
10
35
7.5
10
415/460V
14 (10)
14
18
50
14
18
380V
18 (14)
18
22
50
18
22
220/250V
30 (25)
30
35
100
30
35
500V(3P)
10
30
10
250V(2P)
10
30
10
100
100
100
100
100
100
Endurance
Mechanical
8500
25000
25000
25000
25000
25000
(Number of operations)
Electrical
1500
10000
10000
10000
10000
10000
fixed
fixed
fixed
fixed
fixed
fixed
for 3 pole
Auxiliary switch
Alarm switch
Shunt trip
Undervoltage trip
Terminal shield
Insulation barrier
Rear connection
Plug-in device
Dimensions (mm)
WHD (3P)
7513060
Weight(kg)
2 pole
0.5
0.5
0.5
0.7
0.5
0.5
3 pole
0.7
0.7
0.7
0.7
0.7
4 pole
0.9
0.9
0.9
1.2
0.9
0.9
External accessories
28
7513060
9015560
7513060
100
250
125
N-Type
S-Type
H-Type
N-Type
S-Type
H-Type
ABN102c
ABS102c
ABH102c
ABN202c
ABS202c
ABH202c
ABN103c
ABS103c
ABH103c
ABN203c
ABS203c
ABH203c
ABN104c
ABS104c
ABH104c
ABN204c
ABS204c
ABH204c
690
690
690
690
690
690
500
500
500
500
500
500
750
750
750
750
750
750
10
10
10
25
30
18
26
30
18
37
50
26
37
50
22
42
50
30
42
50
35
85
100
65
85
100
10
20
30
10
20
30
10
20
30
10
20
30
100
100
100
100
100
100
25000
25000
25000
25000
25000
25000
10000
10000
10000
5000
5000
5000
fixed
fixed
fixed
fixed
fixed
fixed
7513060
9015560
10516560
0.5
0.7
0.7
1.1
1.1
1.1
0.7
1.2
1.2
1.2
0.9
1.2
1.2
1.6
1.6
1.6
Amb. Temp.
In=15 to 30
In=40 to 100
In=100 to 225
In=250 to 800
-5C
111.9%
110.2%
114.3%
110.0%
0C
111.3%
109.8%
113.2%
109.0%
10C
110.0%
108.7%
110.6%
107.0%
20C
108.0%
107.0%
107.5%
105.0%
25C
106.6%
105.8%
105.8%
104.0%
30C
104.9%
104.3%
104.0%
103.0%
35C
102.7%
102.4%
102.0%
101.5%
40C
100.0%
100.0%
100.0%
100.0%
45C
96.8%
97.2%
97.9%
98.5%
50C
93.3%
94.0%
95.6%
97.0%
29
Frame Size(AF)
Type
Type and Pole
Rated current, In
400
N-Type
S-Type
H-Type
L-Type
2 pole
ABN402c
ABS402c
ABH402c
ABL402c
3 pole
ABN403c
ABS403c
ABH403c
ABL403c
4 pole
ABN404c
ABS404c
ABH404c
ABL404c
Rated operational
AC(V)
690
690
690
690
voltage, Ue
DC(V)
500
500
500
500
750
750
750
750
kV
14
DC
690V
10
480/500V
18
35
50
65
415/460V
37
50
65
85
380V
42
65
70
100
220/250V
50
75
85
125
500V(3P)
10
20
40
40
250V(2P)
10
20
40
40
100
100
100
75
Mechanical
4000
4000
4000
4000
(Number of operations)
Electrical
1000
1000
1000
1000
Thermal-magnetic release
fixed
fixed
fixed
fixed
Hydraulic-magnetic release
for 3 pole
Auxiliary switch
Alarm switch
Shunt trip
Undervoltage trip
Terminal shield
Insulation barrier
Rear connection
Mechanical interlock
Plug-in device
External accessories
140257109
Dimensions (mm)
WHD (3P)
Weight(kg)
2 pole
5.2
5.2
5.2
5.2
3 pole
6.2
6.2
6.2
6.2
4 pole
7.8
7.8
7.8
7.8
30
800
1000
1200
N-Type
S-Type
L-Type
S-Type
L-Type
ABN802c
ABS802c
ABL802c
ABN803c
ABS803c
ABL803c
ABS1003b
ABL1003b
ABS1203b
ABS1203bE
ABL1203b
ABS804c
ABL804c
ABS1004b
ABL1004b
ABS1204b
ABL1204b
ABN804c
S-Type
L-Type
1200
1000
690
690
690
600
600
600
600
500
500
500
600
-
750
750
750
690
690
690
690
690
10
14
25
45
65
50
75
50
50
75
37
65
85
65
85
65
65
85
45
75
100
65
85
65
65
85
50
85
125
100
125
100
100
125
10
20
40
10
20
40
100
100
75
50
50
50
50
50
2500
2500
2500
2500
2500
2500
2500
2500
500
500
500
500
500
500
500
500
fixed
fixed
fixed
fixed
fixed
fixed
fixed
Adjustable
210280109
220400105
220400105
11
11
11
11.5
11.5
11.5
19.6
19.6
18.2
18.2
18.2
25.7
25.7
25.7
Amb. Temp.
In=15 to 30
In=40 to 100
In=100 to 225
In=250 to 800
-5C
111.9%
110.2%
114.3%
110.0%
0C
111.3%
109.8%
113.2%
109.0%
10C
110.0%
108.7%
110.6%
107.0%
20C
108.0%
107.0%
107.5%
105.0%
25C
106.6%
105.8%
105.8%
104.0%
30C
104.9%
104.3%
104.0%
103.0%
35C
102.7%
102.4%
102.0%
101.5%
40C
100.0%
100.0%
100.0%
100.0%
45C
96.8%
97.2%
97.9%
98.5%
50C
93.3%
94.0%
95.6%
97.0%
31
Frame Size(AF)
Type and Pole
30
N-Type
S-Type
H-Type
N-Type
2-pole
EBN52c
3-pole
EBS33c
EBN53c
EBS53c
EBH53c
EBN63c
EBS63c
EBS34c
EBS54c
EBH54c
EBS64c
4-pole
Overload,
Protective function
Short-circuit and
Ground fault
Rated current, In
mA
AC(V)
kV
voltage, Uimp
Residual current off-time at In
60
50
S-Type
Type
sec
Overload,
Overload,
Short-circuit and Ground fault
Short-circuit and
Ground fault
S-Type
Overload,
Short-circuit and Ground fault
15, 20, 30
30, 100/200/500
30, 100/200/500
30, 100/200/500
30,100/200/500
220/460
220/460
220/460
220/460
0.1 sec
0.1 sec
0.1 sec
0.1 sec
60
40, 50
460V
14
14
18
50
14
18
415V
14
14
18
50
14
18
220/250V
30
30
35
100
30
35
100
100
100
100
100
100
Endurance
Mechanical
25000
25000
25000
25000
25000
25000
(Number of operations)
Electrical
10000
10000
10000
10000
10000
10000
Category of use
Thermal-magnetic
Thermal-magnetic
Thermal-magnetic
Electronic
Electronic
Electronic
Accessories
Electrical auxiliaries
Auxiliary switch
Alarm switch
Insulation barrier
Shunt trip
Undervoltage trip
External accessories
Plug-in kit
Dimensions (mm)
WHD (3P)
7513060
Weight(kg)
2 pole
0.5
3 pole
0.7
0.7
0.7
0.7
0.7
4 pole
0.9
0.9
1.2
0.9
32
9015560
7513060
7513060
100
250
125
N-Type
S-Type
H-Type
N-Type
S-Type
EBN102c
EBN202c
EBN103c
EBS103c
EBH103c
EBN203c
EBS203c
EBH203c
EBN104c
EBS104c
EBH104c
EBS204c
EBH204c
H-Type
Overload,
Short-circuit and Ground
30, 100/200/500
30,100/200/500
30,100/200/500
220/460
220/460
220/460
0.1 sec
0.1 sec
0.1 sec
fault
18
37
50
26
37
18
37
50
26
37
50
35
85
100
65
85
100
100
100
100
100
100
25000
25000
25000
20000
20000
20000
10000
10000
10000
5000
5000
5000
Thermal-magnetic
Thermal-magnetic
Thermal-magnetic
Electronic
Electronic
Electronic
50
7513060
9015560
10516560
0.5
1.1
0.7
1.2
1.2
1.2
0.9
1.2
1.2
1.5
1.5
33
Frame Size(AF)
Type
Type and Pole
400
N-Type
S-Type
H-Type
L-Type
3-pole
EBN403c
EBS403c
EBH403c
EBL403c
4-pole
EBN404c
EBS404c
EBH404c
EBL404c
Protective function
Rated current, In
AC(V)
kV
voltage, Uimp
Residual current off-time at In
sec
30, 100/200/500mA
220/460
220/460
220/460
220/460
0.1 sec
0.1 sec
0.1 sec
0.1 sec
415/460V
37
50
65
85
220/250V
50
75
85
125
100
100
100
75
Mechanical
40000
40000
40000
40000
(Number of operations)
Electrical
10000
10000
10000
10000
Overcurrent pick-up
Electronic
External accessories
Auxiliary switch
Alarm switch
Shunt trip
Undervoltage trip
Insulation barrier
Plug-in kit
Dimensions (mm)
WHD (3P)
Weight(kg)
2 pole
3 pole
4 pole
8.4
8.4
34
140257109
1000
1200
N-Type
S-Type
800
L-Type
S-Type
S-Type
EBN803c
EBS803c
EBL803c
EBS1003b
EBS1203b
1000
1200
30, 100/200/500mA
100/200/500mA
100/200/500mA
220/460
220/460
220/460
220/460
220/460
0.1 sec
0.1 sec
0.1 sec
0.1 sec
0.1 sec
37
65
85
85
85
50
85
125
125
125
100
100
75
2500
2500
2500
2500
2500
500
500
500
500
500
Thermal-magnetic
Thermal-magnetic
Thermal-magnetic
Electronic
Electronic
Electronic
210280109
220565105
11.5
11.5
11.5
27.1
27.1
35
Type
(AF)
Ampere frame
Rated current(A)
Setting current (A)
(In max)
at 40
AH-06D
AH-08D
AH-10D
AH-13D
AH-16D
AH-20D
630
800
1000
1250
1600
2000
200
400
400
630
1000
1250
1600
2000
630
800
1600
2000
400
630
400
630
1000
1250
800
(Ui)
1000
(Ue)
690
(Uimp)
12
50/60
Frequency (Hz)
3, 4
(Icu)
AC 50/60Hz
220V/230V/380V/415V
85
460V/480V/500V
85
65
550V/600V/690V
(Ics)
100%
... %Icu
220V/230V/380V/415V
187
460V/480V/500V
187
AC 50/60Hz
550V/600V/690V
143
Rated short-time
1sec
65
2 sec
60
3 sec
50
40
(Icm)
80
20,000
Mechanical
5,000
Electrical
Connections
**
Weight (kg)
Horizontal connection
Vertical connection
Front connection
Mixed connection
63/74
70/85
61/72
68/83
29/32
33/40
34/44
38/47
32/42
36/45
Draw-out
3P
430334375
type
4P
430419375
Fixed type
3P
300300295
4P
300385295
Draw-out / Fixed
Draw-out type
Main body
(With cradle)
(3P/4P)
Cradle only
Fixed type
External dimensions (mm)
(HWD)
H
D
W
N, A, P, S type
Trip relay
Marine classification
* Refer to trip relay specification.
** : Standard, : Option
36
AH-06E
AH-08E
AH-10E
AH-13E
AH-16E
AH-20E
AH-25E
AH-32E
AH-40E
AH-40G
AH-50G
AH-63G
630
800
1000
1250
1600
2000
2500
3200
4000
4000
5000
6300
630
800
1000
1250
1600
2000
2500
3200
4000
4000
5000
6300
800
1000
1250
1600
2000
3200
4000
4000
5000
1,000
1,000
690
690
12
12
50/60
50/60
3, 4
3, 4
100
150
100
150
85
100
100%
100%
220
330
220
330
187
220
85
100
75
85
65
75
40
40
80
80
15,000
10,000
5,000
6300
2,000
87/103
104/147
181/223
186/230
85/101
102/145
179/221
184/228
44/55
58/70
97/117
102/124
44/55
63/100
98/123
103/130
42/53
61/98
96/121
101/128
430412375
460785375
430527375
4601015375
300378295
300751295
300493295
300981295
N, A, P, S type
N, A, P, S type
37
Type
(AF)
Ampere frame
Rated current(A)
Setting current (A)
(In max)
at 40
AN-06D
AN-08D
AN-10D
AN-13D
AN-16D
AS-20D
630
800
1000
1250
1600
2000
200
400
400
630
1000
1250
1600
2000
630
800
1600
2000
400
630
400
630
1000
1250
800
(Ui)
1000
(Ue)
690
(Uimp)
12
50/60
Frequency (Hz)
3, 4
65
70
460V/480V/500V
65
70
550V/600V/690V
50
65
100%
100%
220V/230V/380V/415V
143
154
460V/480V/500V
143
154
AC 50/60Hz
550V/600V/690V
105
143
Rated short-time
1 sec
50
65
2 sec
42
55
3 sec
36
(Icu)
AC 50/60Hz
Rated service breaking capacity (kA)
(Ics)
... %Icu
(Icm)
(Icw)
50
40
80
20,000
Mechanical
5,000
Electrical
Connections
**
Weight (kg)
Draw-out / Fixed
Draw-out type
Main body
(With cradle)
(3P/4P)
Horizontal connection
Vertical connection
Front connection
Mixed connection
63/74
70/85
61/72
68/83
29/32
33/40
34/44
38/47
32/42
36/45
3P
430334375
Cradle only
Fixed type
External dimensions (mm)
(HWD)
Draw-out
H
D
type
4P
430419375
Fixed type
3P
300300295
4P
300385295
N, A, P type
Trip relay
Marine classification
* Refer to trip relay specification.
** : Standard, : Option
38
AS-20E
AS-25E
AS-32E
AS-40E
AS-40G
AS-50G
AS-63G
2000
2500
3200
4000
4000
AS-50F
5000
4000
5000
6300
2500
3200
4000
4000
5000
4000
5000
6300
630, 800
1000, 1250
1600, 2000
(0.4 ~ 1.0) In max
630, 800
1000, 1250
2500
3200
4000
4000
5000
4000
5000
6300
1600, 2000
1,000
1000
1,000
690
690
690
12
12
12
50/60
50/60
50/60
3, 4
3, 4
3, 4
85
100
120
85
100
120
85
85
100
100%
100%
100%
187
220
264
187
220
264
187
187
220
85
85
100
75
75
85
65
65
75
40
40
40
80
80
80
15,000
10,000
10,000
2,000
2,000
5,000
87/103
104/147
145/173
181/223
85/101
102/145
143/171
179/221
184/228
44/50
58/70
78/90
97/117
102/124
44/55
63/100
76/94
98/123
103/130
42/53
61/98
74/92
96/121
101/128
430412375
460629375
460785375
430527375
460799375
4601015375
300378295
300597295
300751295
300493295
300767295
300981295
N, A, P type
186/230
N, A, P type
N, A, P type
39
Trip relay(OCR)
The trip relay of Susol ACB provides the additional protection functions for voltage, frequency, unbalance, and
others in addition to main protection functions for over current, short-circuit, ground fault. It supports the
advanced measurement functions for voltage, current, power, electric energy, harmonics, communication
function, and others.
Analog trip function interlocked with mechanism enhanced a durability of devices as well as the breaking
capacity of ACB.
Zone selective interlocking function makes the protective coordination more simple and thermal memory can
be applied to various loads.
N type
A type
P type
S type
Externals
Current
protection
L / S / I / G / Thermal
Other
protection
L / S / I / G / Thermal
ZSI(Protective coordination)
Earth leakage (Option)
Current (R / S / T / N)
Measurement
function
Fine adjustment
Digital Output
IDMTL setting
Communication
Power supply
RTC timer
LED for
trip info.
Self Power
-Power source
works over 20% of
load current.
Available
Long time delay
Short time delay/Instantaneous
Ground fault
Fault recording
Event recording
Operating
Reset button
button
3DO (Fixed)
L, S/I, G Alarm
-
L / S / I / G / Thermal(Continuous)
ZSI(Protective coordination)
Earth leakage(Option)
Over/Under current
Over/Under frequency
Unbalance(Voltage/Current)
Reverse power
3 Phase Voltage/Current
RMS/Vector
Power(P, Q, S), PF(3-Phase)
Energy(Positive/Negative)
Frequency, Demand
P type
P type
3 Phase Voltage/Current
RMS/Vector
Power(P, Q, S), PF(3-Phase)
Energy(Positive/Negative)
Frequency, Demand
Voltage/Current harmonics
(1st~63th)
3 Phase Waveforms
THD, TDD, K-Factor
P type
P type
P type
P type
Modbus/RS-485
Profibus-DP
Self Power
- Power source works
over 20% of load current.
- External power source are
required for comm.
AC/DC 100~250V
DC 24~60V
Available
N type
Modbus / RS-485
Profibus-DP
AC/DC 100~250V
DC 24~60V
Available
N type
Available
N type
10records
(Fault/Current/Date and Time)
256records
(Fault/Current/Date and Time)
Reset, Menu
Up/Down, Left/Right, Enter
256records
Last fault wave
recording (3 Phase)
P type
A type
41
Features:
- Designed to provide higher level of safety for final distribution board
- Pan assembly type busbar systems to provide easier cabling
- Split neutral bars provide easy connection and maximum cable space
- Easy and safe mounting of LS Miniature Circuit Breaker
- Flush and surface mounted
-Tin plate and cooper busbar
- Galvanized 1.2mm steel sheet
Technical Description
- In compliance with standards : IEC 60439-3
- Short-circuit withstand: 17kA/0.2s
- Peak short time withstand: 35kA
- Index of degree: IP 4X
- Rated operational Voltage(Ue): 415V
- Rated insulation Voltage(Ui): 460V
- Rated Frequence: 50/60Hz
- Rated impuls withstand Voltage(Uimp): 4kV
- Rated Current (In): Upto 125A
42
Internal view
Enclosure
Earth Link
Neutral Linker
Pan Assembly
Insulation Cover
Incomer
43
Side view
Front view
Selection of Enclosure
Code Description
Type
Dimension
530H430W110D mm
580H430W110D mm
680H430W110D mm
780H430W110D mm
780H430W 110D mm
830H430W110D mm
980H430W110D mm
980H430W110D mm
980H430W110D mm
510H410W110D mm
560H410W110D mm
660H410W110D mm
760H410W110D mm
760H410W110D mm
810H410W110D mm
960H410W110D mm
960H410W110D mm
960H410W110D mm
Flush
Surface
Side view
Front view
Selection of Enclosure
Code Description
4 Way DB 1 INC
6 Way DB 1 INC
8 Way DB 1 INC
12 Way DB 1 INC
14 Way DB 1 INC
18 Way DB 1 INC
20 Way DB 1 INC
24 Way DB 1 INC
4 Way DB 1 INC
6 Way DB 1 INC
8 Way DB 1 INC
12 Way DB 1 INC
14 Way DB 1 INC
18 Way DB 1 INC
20 Way DB 1 INC
24 Way DB 1 INC
44
Type
Flush
Surface
Dimension
530H430W110D mm
580H430W110D mm
680H430W110D mm
780H430W110D mm
830H430W110D mm
980H430W110D mm
Customized available
Customized available
510H410W110 D mm
560H410W110 D mm
660H410W110 D mm
760H410W110 D mm
810H410W110 D mm
960H410W110 D mm
Customized available
Customized available
Specific of FDB
Single busbar & Dual Incomer type
Side view
Front view
Selection of Enclosure
Code Description
4 Way DB 2 INC
6 Way DB 2 INC
8 Way DB 2 INC
12 Way DB 2 INC
14 Way DB 2 INC
18 Way DB 2 INC
20 Way DB 2 INC
24 Way DB 2 INC
4 Way DB 2 INC
6 Way DB 2 INC
8 Way DB 2 INC
12 Way DB 2 INC
14 Way DB 2 INC
18 Way DB 2 INC
20 Way DB 2 INC
24 Way DB 2 INC
Type
Dimension
530H430W110D mm
580H430W110D mm
680H430W110D mm
780H430W110D mm
830H430W110D mm
980H430W110D mm
Customized available
Customized available
510H410W110D mm
560H410W110D mm
660H410W110D mm
760H410W110D mm
810H410W110D mm
960H410W110D mm
Customized available
Customized available
Flush
Surface
Lock
Side view
Front view
Selection of Enclosure
Code Description
6 Way 1P C.Unit
9 Way 1P C.Unit
12 Way 1P C.Unit
15 Way 1P C.Unit
18 Way 1P C.Unit
22 Way 1P C.Unit
Type
Dimension
320H240W100D mm
370H240W100D mm
420H250W100D mm
490H250W100D mm
550H250W100D mm
Customized available
45
LS SMDB Solution
Rating
A wide choice of incoming MCCBs make LS SMDB panesboards flexible to suit most of the requirements and represent excellent value and
will apeal to consultants, contractors. end users and OEMs. These are offered in ratings of 125A, 250A, 400A, 630A.
All incoming and outgoing MCCBs have Thermal/Magnetic fixed and adjustable tripping mechanisms incorporated with a trip-to-test button.
These are available in ratings as follows : 16, 20, 25, 32, 40, 50, 63, 80, 100, 125, 160, 250, 400, 630A.
Technical Specifications
Constructional Characteristics
Complied with IEC 60947-1
Fully Type Tested, ASTA Certified
Degree of protection : IP41 as per IEC 60529
Form of separation: Form 3b
Enclosure constructed from rigid folded zinc phosphate and protected both internally and externally with polyester powder coating
Electrical Characteristics
Rated Operational Voltage Ue: upto 690V
Rated Insulation voltage Ui: upto 750V
Rated Frequency: 50/60Hz
Rated Impulse withstand voltage Uimp: 8kV
Rated Short time Icw & peak withstand Ipk Current: 36kA/1S
46
Incoming Devices
MCCB Panelboards
Metasol Series
No of
Width
Height
Depth
700
800
180
700
800
700
No of
Width
Height
Depth
700
1000
250
180
700
1000
250
800
180
700
1200
700
1000
180
10
700
10
700
1200
180
12
12
700
1200
180
14
Ways
Ways
No of
Width
Height
Depth
800
1000
250
250
800
1200
250
1400
250
10
800
1400
250
700
1400
250
12
800
1400
250
700
1600
250
14
800
1600
250
Ways
No of
Width
Height
Depth
700
800
180
700
800
700
No of
Width
Height
Depth
700
1000
250
180
700
1000
250
800
180
700
1200
700
1000
180
10
700
10
700
1200
180
12
12
700
1200
180
14
Ways
Ways
No of
Width
Height
Depth
800
1000
250
250
800
1200
250
1400
250
10
800
1400
250
700
1400
250
12
800
1400
250
700
1600
250
14
800
1600
250
Ways
47
LS SMDB Solution
Incoming Devices
750V
Incoming application
TS250
TS400
TS630
50
85
150
50
85
150
50
85
150
100% Icu
100% Icu
Ics.........% Icu
Thermal magnetic / Electronic
TS250NA
TS400NA
TS630NA
4.9
7.1
8.5
690V
Breaker type
Incoming application
ABS203c
ABS403c
ABS803c
37
50
65
100% Icu
100% Icu
100% Icu
48
Thermal magnetic
Outgoing devices
Rated current, In
upto 750V
Breaker type
No. of poles
1P
3P
1P
3P
1P
3P
30
100
50
120
200
Incoming application
ABS103c
N
No. of poles
2P
H
3P
2P
L
3P
2P
3P
85
100
18
37
50
Thermal magnetic
49
7.2kV (VL-06)
Type
VL-060804
Rated voltage
VL-061306
Ur (kV)
7.2
Ir (A)
Rated frequency
400
630
fr (Hz)
50/60
8
12.5
Ik/tk (kA/s)
8/3
12.5/3
(MVA)
100
Ip (kA)
Isc (kA)
160
2.5 * Isc (50Hz)/2.6 * Isc (60Hz)
(cycle)
Rated withstand
Ud (kV)
20
voltage
Impulse (1.250)
Up (kV)
60
O-0.3s-CO-15s-CO
Closing coil
(V)
Trip coil
(V)
Auxiliary contacts
(sec)
0.04
(sec)
0.06
Mechanical
M2
Electrical
E2 (List1)
C2
Fixed
P type
Drawout
Phase distance
Weight
(mm)
130
(kg)
37
37
(kg)
18, 25, 32
19, 26, 33
Standards
7.2/12/17.5kV (VL-06/12/17)
Type
Rated voltage
VL-0620/2506/13/20
VL-1220/2506/13/20
7.2
12
Ur (kV)
Ir (A)
Rated frequency
630
1250
2000
630
1250
fr (Hz)
Isc (kA)
(MVA)
Ip (kA)
17.5
2000
630
1250
20, 25
20/3, 25/3
250/310
410/520
600/750
(cycle)
Rated withstand
Ud (kV)
20
28 (42)
38
voltage
Impulse (1.250)
Up (kV)
60
75 (82)
95
O-0.3s-CO-15s-CO
Closing coil
(V)
Trip coil
(V)
Auxiliary contacts
4a4b, 10a10b
(sec)
0.04
(sec)
0.06
Mechanical
M2
Electrical
E2 (List3)
C2
P type
Phase distance **
(mm)
(kg)
100
100
(kg)
170
170
50
150
Standards
P type
Drawout
Weight
2000
50/60
Ik/tk (kA/s)
VL-1720/2506/13/20
150 (210)
150 (210)
130
115 (120)
180
170 (200)
7.2/12kV (LVB-06/12)
Type
Rated voltage
Ur (kV)
Ir (A)
Rated frequency
7.2
1250
12
2000
3150
1250
fr (Hz)
Isc (kA)
(MVA)
Ip (kA)
31.5, 40
31.5, 40
31.5/3, 40/3
31.5/3, 40/3
393, 499
393, 499
2.5 * Isc (50Hz)/2.6 * Isc (60Hz)
(Cycle)
Rated withstand
Ud (kV)
20
28
voltage
Impulse (1.250)
Up (kV)
60
75
O-0.3s-CO-3min-CO
Closing coil
(V)
Trip coil
(V)
Auxiliary contacts
4a4b, 10a10b
(sec)
0.04
(sec)
0.06
Mechanical
M2
Electrical
E2 (List1)
C2
3150
50/60
Ik/tk (kA/s)
2000
P type
MCSG Cradle
(mm)
150
210
150
210
(kg)
135, 160
135, 160
210, 220
164
165
220
(kg)
55, 110
63, 117
135, 155
110
117
155
Standards
* MCSG style drawable type provide a cradle for builting in the switchgear, not a box type for CB compartment. Ordering type is LVB.
Note) H type that is a box type cradle for enabling a CB compartment in MCSG is under development. Consult us for ordering.
7.2/12/17.5kV (VH-06/12/17)
Type
Rated voltage
VH-065013/20/25/32
VH-125013/20/25/32
7.2
12
Ur (kV)
Ir (A)
Rated frequency
1250
2000
2500
3150
1250
2000
fr (Hz)
Isc (kA)
(MVA)
Ip (kA)
17.5
2500
3150
1250
2000
2500
50
50/3
623
1039
1515
(cycle)
Rated withstand
Ud (kV)
20
28 (42)
38
voltage
Impulse (1.250)
Up (kV)
60
75 (82)
95
O-0.3s-CO-3min-CO
Closing coil
(V)
Trip coil
(V)
Auxiliary contacts
4a4b, 10a10b
(sec)
0.04
(sec)
0.06
Mechanical
M2
Electrical
E2 (List3)
C2
Fixed
P type
Drawout
Phase distance
Weight
Standards
3150
60
Ik/tk (kA/s)
VH-175013/20/25/32
210
275
210
Breaker (H type)
(kg)
230
287
290
230
287
275
290
210
230
287
275
290
(kg)
175
320
320
175
320
320
175
320
320
51
7.2/12KV (VH-06/12)
Type
VH-0640, 5004
Rated voltage
Ur (kV)
Ir (A)
Rated frequency
Rated short-circuit current
Rated short-time withstand current
VH-1240, 5004
7.2
12
4000
4000
fr (Hz)
50/60
Isc (kA)
40, 50
Ik/tk (kA/s)
(MVA)
Ip (kA)
40/3, 50/3
499, 623
831, 1039
2.5 * Isc (50Hz)/2.6 * Isc (60Hz)
(Cycle)
Rated withstand
Ud (kV)
20
28
voltage
Impulse (1.250)
Up (kV)
60
75
O-0.3s-CO-3min-CO
Closing coil
(V)
Trip coil
(V)
Auxiliary contacts
4a4b, 10a10b
(sec)
0.04
(sec)
0.06
Mechanical
M2
Electrical
E2 (List1)
C2
Fixed
P type
Drawout *
Phase distance
Weight
(mm)
275
(kg)
270, 318
Cradle (K type)
(kg)
315
Standards
* K type cradle drawable type provide a cradle for builting in the switchgear, not a box type for CB compartment. Ordering type is LVB.
24kV (VH-20)
Type
VH-202525
Rated voltage
VH-203213/20/32
Ur (kV)
Ir (A)
Rated frequency
2500
1250
2000
fr (Hz)
Isc (kA)
Ik/tk (kA/s)
(MVA)
Ip (kA)
31.5
40
31.5/3
40/3
1309/1407
1662/1787
1039/1117
3150
(cycle)
3
50 (65) Note)
voltage
Impulse (1.250)
Up (kV)
125
O-0.3s-CO-3min-CO
Closing coil
(V)
Trip coil
(V)
Auxiliary contacts
4a4b, 10a10b
(sec)
0.04
(sec)
0.06
Mechanical
M2
Electrical
E2 (List3)
C2
P type
Drawout
Phase distance **
275
210 (275)
210 (275)
275
275
Breaker (H type)
(kg)
295
256 (273)
256 (273)
318
318
Cradle (H type)
(kg)
316
257 (284)
257 (284)
316
316
Standards
* H type is a box type cradle with CB compartment style structure.
Note) Contact us.
52
2000
25
Ud (kV)
Weight
1250
25/3
3150
60
Rated withstand
Control voltage
VH-204013/20/32
24/25.8
36kV (VH-36)
Type
VH-362513/20/32
Rated voltage
VH-363213/20/32
Ur (kV)
Ir (A)
Rated frequency
1250
2000
3150
1250
2000
fr (Hz)
VH-364013/20/32
36
3150
1250
2000
25
31.5
40
Ik/tk (kA/s)
25/3
31.5/3
40/3
(MVA)
1559
1964
2494
Ip (kA)
Isc (kA)
(cycle)
Rated withstand
Ud (kV)
70 (95) Note)
voltage
Impulse (1.250)
Up (kV)
170
O-0.3s-CO-3min-CO
Closing coil
(V)
Trip coil
(V)
Auxiliary contacts
4a4b, 10a10b
(sec)
0.04
(sec)
0.06
Mechanical
M2
Electrical
E2 (List3)
C2
P type
Drawout
Phase distance
Weight
3150
50/60
(mm)
300
Breaker (H type)
(kg)
400
490
400
490
400
490
Cradle (H type)
(kg)
700
750
700
750
700
750
Standards
40.5kV (VH-40)
Type
VH-402513/20/32
Rated voltage
VH-403213/20/32
Ur (kV)
Ir (A)
Rated frequency
40.5
1250
2000
3150
fr (Hz)
1250
2000
25
31.5
Ik/tk (kA/s)
25/4
31.5/4
(MVA)
1754
Ip (kA)
Isc (kA)
2210
2.5 * Isc (50Hz)
(cycle)
Rated withstand
Ud (kV)
95
voltage
Impulse (1.250)
Up (kV)
180
O-0.3s-CO-3min-CO
Closing coil
(V)
Trip coil
(V)
Auxiliary contacts
4a4b, 10a10b
(sec)
0.04
(sec)
0.06
Mechanical
M2
Electrical
Standards
C2
Fixed
Phase distance
Weight
3150
50
P type
(mm)
Breaker (H type)
(kg)
300
400
490
400
490
GB1984
53
Accessories
Dimensions
Main
Cradle
Earthing S/W
Position S/W
Keylock
Door interlock
Button padlock
MOC
Button cover
TOC
Plug interlock
Shutter padlock
Earthing S/W
Position S/W
Keylock
Door interlock
Button padlock
MOC
Button cover
TOC
Plug interlock
Shutter padlock
F type
No Shutter
Insulation Shutter
For MESG
For MESG
H type
G type
Bushing
Bushing
Insulation Shutter
For MESG
54
For your safety, please read user's manual thoroughly before operating.
Contact the nearest authorized service facility for examination, repair, or adjustment.
Please contact qualified service technician when you need maintenance.
Do not disassemble or repair by yourself!
Safety Instructions
Any maintenance and inspection shall be performed by the personnel having expertise concerned.
HEAD OFFICE
LS-ro 127 (Hogye-dong) Dongan-gu Anyang-si
Gyeonggi-do Korea
Tel. (82-2)2034-4840, 4911, 4914
Fax. (82-2)2034-4648
www.lsis.com
Global Network
LSIS USA Inc.
Chicago, America
Address: 2000 Millbrook Drive, Lincolnshire, Chicago, IL 60069, United States of America
Tel: 847-941-8240 Fax: 847-941-8259 e-mail: seungheonc@lsis.com
CHEONG-JU PLANT
Cheong-Ju Plant #1, 95 Baekbong-ro Heungdeok-gu
Cheongju-si Chungcheongbuk-do 361-720 Korea
2014. 03
LSIS Electric Products (E) 2004. 02/(40) 2014. 03. Printed in Korea STAFF