Documente Academic
Documente Profesional
Documente Cultură
CERTIFIED
EMI Power
Filters
Spectrum Control EMI filtered power products prevent
unwanted interference from entering your system, as
well as eliminate emissions that can contaminate the
AC power grid. Our standard and custom products
are available in a wide range of AC/DC current and
voltage ratings to address EMI filtering for high current
applications. All Spectrum power products are
designed to meet global EMC emissions regulations.
Spectrum Control is committed to providing an
integrated approach to EMC problem solving by offering
customers consulting, diagnostic testing, design and
manufacturing services. As a fully integrated manufacturer,
Spectrum Control is able to respond to short lead time
requests for new prototypes and variations to standard
products. This enables us to provide the most costeffective solution that satisfies both your performance
and budgetary needs.
In addition, our family of power products provide
low cost solutions to EMI challenges, helping you
lower inventories and increase production assembly
efficiency.
Spectrum Control power products are used in
a variety of industries worldwide, including telecommunications, computers and peripherals, medical,
aerospace, military, power supplies, appliances
and industrial controls.
CERTIFIED
Control Products
Systems Company
&
12 - 22
Fused Filtered
Power Entry Modules
24 - 51
Miniature Printed
Circuit Boards
52 - 59
Appliance Filters
Single Stage
Single Stage Wire Leads
Single Stage Wire Leads for
Medical Purpose Applications
Military/Aerospace
Multisection Filters
Custom/Application
Specific Filters
Appendix
23
60 - 97
Military/Aerospace
Multisection Filters
98 - 105
Custom/Application
Specific Filters
106 - 109
110 - 115
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Applications
High Current
Terminal Blocks
Features/
Benefits
Performance
Characteristics
Power Entry
Modules
High Current
Feed-thru Filters
Pages 24-41
www.spectrumcontrol.com/pem
www.spectrumcontrol.com/pemfsf
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Applications
Commercial Custom
Assemblies
Telecommunications, cellular
base stations, medical
equipment, telephone
switching, traffic control
systems, industrial work
stations, servers, power
supplies, UPS, industrial
controls and welders
Performance
Characteristics
Military/Aerospace
Multisection Filters
Features/
Benefits
Three-Phase
Power Line
Filters
Pages 98-105
www.spectrumcontrol.com/multi
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Test
Design
Manufacture
Flexible factories
Custom designs
Spectrum Control, Inc. ISO 9001 certified
Schedule sharing programs available
Vertically integrated supplier
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Application Guidelines
INCORRECT
CORRECT
CABINET
POWER
INPUT
DENOTES
COUPLING
FROM NOISY
CIRCUITS
BACK TO
LINE
CABINET
DENOTES
COUPLING
FROM NOISY
CIRCUITS
BACK TO
LINE
POWER
INPUT
Interference types
There are two modes of conducted noise: differential
mode (symmetrical or normal mode) and common mode
(asymmetrical mode).
Differential mode interference signals are present on
one side of the line, referenced to the other. The currents
flow along one phase and return along another phase.
Common mode interference signals are present on both
sides of the line referenced to ground. The current flows
from the source to ground along the ground path and
returns along the phases.
Sources of EMI
Electromagnetic interference can occur naturally
or through electronic sources. Lightning discharges,
precipitation, sand and dust storms, and cosmic noise
are sources of natural EMI.
EMI generated from power electrical products cause
the most concern. These man-made sources, such as
power lines, rotating machinery, power supplies and
electronic transmission devices, all have their own
signatures and noise pollution.
LINE
FILTER
CLEAN
LINE
LINE FILTER
Installation Criteria
Proper installation of a filter network is critical to achieving
successful filtering of electromagnetic interference.
Spectrum Control recommends that power line filters be
installed where the power line enters the equipment. The
filter acts as a barrier between polluted energy and clean
energy going into your equipment. It is important that the
filter is connected to an effective ground plane and where
proximity does not couple radiated noise to the clean lines.
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Measurement Guidelines
Leakage Current
Leakage is a measurement of reactive current (capacitance) to ground per line. Spectrum Control uses the
following test setup for leakage current measurement.
TIES TO CHASSIS
OF DEVICE
DEVICE
UNDER
TEST
1
AC
SOURCE
2
0.15 FD
1 NEUTRAL TEST
2 HIGH TEST
1.5 K
v
IN ACCORDANCE WITH U.L. 1283 METHOD
AC Voltage Drop
AC voltage drop is defined as E in - E out = AC
voltage drop.
Spectrum Control uses the following circuit for AC voltage
drop testing:
A
DUT
(FILTER)
E1
BALUN
INSULTATED TABLE
E2
BALUN
FILTER
A
50
FILTER
B
SIGNAL
GENERATOR
50
RECEIVER
Common (Asymmetrical)
Mode Insertion Loss
E VD
LINE
DUT
(FILTER)
RS
LINE
50
50
FILTER
NEUT
DC Voltage Drop
DC voltage drop is performed on each line individually.
This test provides the total DC voltage drop for that line
of the filter. The following circuit is used in testing:
FILTER
C
RECEIVER
NEUT
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
State-of-the-art Testing
Testing Capabilities
UL Underwriters Laboratories, UL 1283
MILITARY
MIL-STD-461 A/B/C/D and MIL-STD-1399
AUTOMOTIVE
SAE-J1113, SAE-J551
COMMERCIAL
FCC-Part 15
RTCA-DO-160 A/B/C
Boeing-16050-2
Bellcore-TR-NWT-001089
INTERNATIONAL
EN 55011 (CISPR 11)
EN 55014 (CISPR 14)
EN 55022 (CISPR 22)
IEC-1000-4-02 ESD
IEC-1000-4-03 RFI
IEC-1000-4-04 EFT
IEC-1000-4-05 Surge
10
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Test
Design
Manufacture
Flexible operations
Custom designs built in U.S.A.
ISO 9001 certified facilities
Workmanship MIL-STD-2000
certified
Schedule sharing programs
available
Vertically integrated
EMI filter supplier
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
11
High Current
DC Single Line
Feed-thru Series
Features
Applications
Specifications
Part
Number
52-226-011-10
52-226-011-16
52-226-011-32
52-226-011-63
52-226-011-100
52-226-011-200
52-226-011-250
52-226-011-300
52-226-021-16
52-226-021-32
52-226-031-63
52-226-021-100
52-226-021-200
52-226-021-250
52-226-021-300
52-226-031-16
52-226-031-32
52-226-031-63
52-226-031-100
52-226-031-200
52-226-031-250
52-226-031-300
52-226-041-16
52-226-041-32
52-226-041-63
52-226-041-100
52-226-041-200
Rated
Current
10A
16A
32A
63A
100A
200A
250A
300A
16A
32A
63A
100A
200A
250A
300A
16A
32A
63A
100A
200A
250A
300A
16A
32A
63A
100A
200A
Min.
Cap.
.01MHz
10nF
.10MHz
100MHz
1000MHz
21
41
60
15
34
53
74
100nF
21
40
60
85
47nF
15
34
53
74
100nF
21
40
60
85
47nF
470nF
16
33
52
75
90
100nF
21
40
60
85
470nF
16
33
52
75
1000nF
20
40
60
85
470nF
16
33
52
75
1000nF
4700nF
6
15
20
35
40
54
60
74
85
90
90
12
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
High Current
DC Single Line
Feed-thru Series
B
E
WORKORDER NO.
DATE CODE
SINGLE "D"
MOUNTING FLAT
Dimensions
Part Number
52-226-011-10
52-226-011-16
52-226-011-32
52-226-011-63
52-226-011-100
52-226-011-200
52-226-011-250
52-226-011-300
52-226-021-16
52-226-021-32
52-226-031-63
52-226-021-100
52-226-021-200
52-226-021-250
52-226-021-300
52-226-031-16
52-226-031-32
52-226-031-63
52-226-031-100
52-226-031-200
52-226-031-250
52-226-031-300
52-226-041-16
52-226-041-32
52-226-041-63
52-226-041-100
52-226-041-200
2.24 (57)
0.39 (10)
0.51 (13)
0.56 (14.29)
0.63 (16)
2.48 (63)
0.47 (12)
0.67 (17)
0.75 (19.05)
0.71 (18)
3.78 (96)
4.45 (113)
5.12 (130)
0.55 (14)
0.63 (16)
0.87 (22)
1 (25.40)
1.18 (30)
1.06 (27)
1.25 (31.75)
1.02 (26)
1.26 (32)
1.57 (40)
1.57 (40)
2 (50.80)
1.81 (46)
1.65 (42)
5.83 (148)
0.75 (19)
2.95 (75)
0.47 (12)
0.67 (17)
0.75 (19.05)
0.71 (18)
3.78 (96)
4.45 (113)
5.12 (130)
0.55 (14)
0.63 (16)
0.87 (22)
1 (25.40)
1.06 (27)
1.25 (31.75)
1.02 (26)
1.26 (32)
1.57 (40)
1.57 (40)
2 (50.80)
1.81 (46)
6.30 (160)
0.75 (19)
0.71 (18)
1.30 (33)
1.18 (30)
1.30 (33)
2.13 (54)
2.95 (75)
0.47 (12)
0.67 (17)
0.75 (19.05)
0.71 (18)
3.78 (96)
4.45 (113)
5.79 (147)
0.55 (14)
0.63 (16)
0.87 (22)
1 (25.40)
1.25 (31.75)
1.5 (38.10)
1.02 (26)
1.26 (32)
1.57 (40)
1.30 (33)
1.97 (50)
2 (50.80)
1.81 (46)
2.83 (72)
7.01 (178)
3.23 (82)
3.98 (101)
5.24 (133)
6.50 (165)
0.75 (19)
0.63 (16)
0.75 (19)
1.06 (27)
1.57 (40)
1.06 (27)
1.57 (40)
1.25 (31.75)
1.5 (38.10)
2 (50.80)
0.71 (18)
1.02 (26)
1.26 (32)
1.57 (40)
1.18 (30)
1.30 (33)
1.97 (50)
2.68 (68)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
13
High Current
DC Single Line
Pi Series
Features
Applications
Circuit Diagram
Specifications
Part
Number
Standard Performance
52-226-020-10
52-226-020-16
52-226-020-32
52-226-020-63
52-226-020-100
52-226-020-200
High Performance
52-226-029-10
52-226-029-16
52-226-029-32
52-226-029-63
52-226-029-100
52-226-029-200
Rated
Current
10A
16A
32A
63A
100A
200A
10A
16A
32A
63A
100A
200A
Min.
Cap. (2X)
10nF
.01MHz
.10MHz
0.5
8
10
27
23
35
23
67
70
60
470nF
4
7
2
8
21
23
100nF
25
75
470nF
1000nF
4700nF
4
8
20
21
26
40
35
57
85
70
73
90
100nF
30
1000MHz
70
50
90
90
90
90
14
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
High Current
DC Single Line
Pi Series
A
B
F
D
SINGLE "D"
MOUNTING FLAT
DATE CODE
WORKORDER NO.
.025 (.64) SHOULDER
Dimensions
Part Number
Standard Performance
52-226-020-10
52-226-020-16
52-226-020-32
52-226-020-63
52-226-020-100
52-226-020-200
High Performance
52-226-029-10
52-226-029-16
52-226-029-32
52-226-029-63
52-226-029-100
52-226-029-200
0.47 (12)
0.67 (17)
0.75 (19.05)
0.55 (14)
0.63 (16)
0.75 (19)
0.87 (22)
1 (25.40)
1.25 (31.75)
1.50 (38.10)
0.47 (12)
0.67 (17)
3.54 (90)
3.86 (98)
6.30 (160)
7.24 (184)
8.23 (209)
1.06 (27)
5.12 (130)
5.47 (139)
6.81 (173)
8.98 (228)
11 (279)
0.63 (16)
0.75 (19)
1.06 (27)
1.57 (40)
0.75 (19.05)
1.25 (31.75)
1.50 (38.10)
2 (50.80)
0.63 (16)
1.93 (49)
0.71 (18)
2.09 (53)
1.02 (26)
1.26 (32)
1.57 (40)
3.70 (94)
4.09 (104)
4.41 (112)
0.63 (16)
3.50 (89)
0.71 (18)
3.70 (94)
1.02 (26)
1.26 (32)
1.57 (40)
4.13 (105)
5.71 (145)
7.17 (182)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
15
High Current
AC Single Line
Feed-thru Series
Features
Applications
Specifications
Part
Number
52-226-016-10
52-226-016-16
52-226-016-32
52-226-016-63
52-226-016-100
52-226-016-200
52-226-016-250
52-226-016-300
52-226-026-10
52-226-026-16
52-226-026-32
52-226-026-63
52-226-026-100
52-226-026-200
52-226-026-250
52-226-026-300
52-226-036-16
52-226-036-32
52-226-036-63
52-226-036-100
52-226-036-200
52-226-036-250
52-226-036-300
52-226-046-16
52-226-046-32
52-226-046-63
52-226-046-100
52-226-046-200
52-226-046-250
52-226-046-300
Rated
Current
Min.
Cap.
10A
16A
32A
63A
100A
200A
250A
300A
10A
16A
32A
63A
100A
200A
250A
300A
16A
32A
63A
100A
200A
250A
300A
16A
32A
63A
100A
200A
250A
300A
2.2nF
.01MHz
.10MHz
100MHz
1000MHz
30
45
4.7nF
15
34
54
10nF
47nF
4
15
21
34
41
53
60
74
100nF
21
40
60
85
15
34
54
21
41
60
4.7nF
10nF
47nF
100nF
2
5
15
21
34
40
53
60
74
85
220nF
10
27
47
67
90
47nF
33nF
100nF
220nF
2
3
5
10
15
16
21
27
34
35
40
47
16
33
52
75
5
2
10
16
21
15
27
33
40
34
47
52
60
53
67
75
20
40
60
85
470nF
100nF
47nF
220nF
470nF
53
60
67
74
90
85
90
85
74
90
1000nF
16
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
High Current
AC Single Line
Feed-thru Series
B
F
WORKORDER NO.
SINGLE "D"
MOUNTING FLAT
DATE CODE
.025 (.64) SHOULDER
Dimensions
Part Number
52-226-016-10
52-226-016-16
52-226-016-32
52-226-016-63
52-226-016-100
52-226-016-200
52-226-016-250
52-226-016-300
52-226-026-10
52-226-026-16
52-226-026-32
52-226-026-63
52-226-026-100
52-226-026-200
52-226-026-250
52-226-026-300
52-226-036-16
52-226-036-32
52-226-036-63
52-226-036-100
52-226-036-200
52-226-036-250
52-226-036-300
52-226-046-16
52-226-046-32
52-226-046-63
52-226-046-100
52-226-046-200
52-226-046-250
52-226-046-300
2.24 (57)
0.39 (10)
0.51 (13)
0.56 (14.29)
0.63 (16)
2.48 (63)
0.47 (12)
0.67 (17)
0.75 (19.05)
0.71 (18)
3.78 (96)
4.45 (113)
5.12 (130)
0.55 (14)
0.63 (16)
0.87 (22)
1 (25.40)
1.25 (31.75)
1.5 (38.10)
1.02 (26)
1.26 (32)
1.57 (40)
1.18 (30)
1.57 (40)
2 (50.80)
1.81 (46)
1.65 (42)
5.83 (148)
0.75 (19)
1.06 (27)
F
0.71 (18)
1.30 (33)
2.24 (57)
0.39 (10)
0.51 (13)
0.56 (14.29)
0.63 (16)
2.48 (63)
0.47 (12)
0.67 (17)
0.75 (19.05)
0.71 (18)
3.78 (96)
4.45 (113)
5.12 (130)
0.55 (14)
0.63 (16)
0.87 (22)
1 (25.40)
1.25 (31.75)
1.5 (38.10)
1.02 (26)
1.26 (32)
1.57 (40)
1.18 (30)
1.57 (40)
2 (50.80)
1.81 (46)
1.65 (42)
5.83 (148)
0.75 (19)
1.06 (27)
0.71 (18)
1.30 (33)
2.95 (75)
0.47 (12)
0.67 (17)
0.75 (19.05)
0.71 (18)
3.78 (96)
4.57 (116)
5.79 (147)
0.55 (14)
0.87 (22)
1.06 (27)
1 (25.40)
1.02 (26)
1.26 (32)
1.57 (40)
1.30 (33)
1.97 (50)
2 (50.80)
1.81 (46)
2.13 (54)
0.87 (22)
0.67 (17)
1 (25.40)
0.71 (18)
1.18 (30)
1.06 (27)
1.25 (31.75)
1.5 (38.10)
1.02 (26)
1.26 (32)
1.57 (40)
1.30 (33)
1.81 (46)
2.13 (54)
0.75 (19)
6.30 (160)
3.03 (77)
2.95 (75)
4.45 (113)
5.24 (133)
5.79 (147)
6.30 (160)
0.55 (14)
0.47 (12)
0.63 (16)
0.75 (19)
1.57 (40)
1.57 (40)
1.5 (38.10)
2 (50.80)
1.18 (30)
1.97 (50)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
17
High Current
AC Single Line
Pi Series
Features
Circuit Diagram
Applications
Specifications
Part
Number
Standard Performance
52-226-037-10
52-226-037-16
52-226-037-32
52-226-037-63
52-226-037-100
52-226-037-200
52-226-037-250
52-226-037-300
High Performance
52-226-019-10
52-226-019-16
52-226-019-32
52-226-019-63
52-226-019-100
52-226-019-200
52-226-019-250
52-226-019-300
Rated
Current
Min.
Cap. (2X)
10A
16A
32A
63A
100A
200A
250A
300A
4.7nF
10A
16A
32A
63A
100A
200A
250A
300A
10nF
.01MHz
47nF
100nF
10nF
22nF
.10MHz
100MHz
19
77
22
50
4
8
21
25
52
73
80
26
75
30
15
47
27
39
75
150nF
12
470nF
21
57
85
1000MHz
90
90
80
90
90
18
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
High Current
AC Single Line
Pi Series
A
B
F
D
SINGLE "D"
MOUNTING FLAT
DATE CODE
WORKORDER NO.
.025 (.64) SHOULDER
Dimensions
Part Number
Standard Performance
52-226-037-10
52-226-037-16
52-226-037-32
52-226-037-63
52-226-037-100
52-226-037-200
52-226-037-250
52-226-037-300
High Performance
52-226-019-10
52-226-019-16
52-226-019-32
52-226-019-63
52-226-019-100
52-226-019-200
52-226-019-250
52-226-019-300
0.47 (12)
0.67 (17)
0.75 (19.05)
0.63 (16)
0.71 (18)
2.24 (57)
2.40 (61)
0.55 (14)
0.63 (16)
0.87 (22)
1 (25.40)
1.25 (31.75)
1.02 (26)
1.26 (32)
1.57 (40)
3.7 (94)
4.09 (104)
4.41 (112)
1.81 (46)
3.66 (93)
3.86 (98)
4.17 (106)
6.30 (160)
7.24 (184)
8.23 (209)
7.87 (200)
0.75 (19)
1.06 (27)
1.57 (40)
1.5 (38.10)
4.21 (107)
0.47 (12)
0.67 (17)
0.75 (19.05)
0.63 (16)
2.6 (66)
4.57 (116)
0.55 (14)
0.87 (22)
1 (25.40)
0.71 (18)
2.72 (69)
6.81 (173)
8.98 (228)
9.57 (243)
0.63 (16)
1.06 (27)
1.25 (31.75)
1.5 (38.10)
1.02 (26)
1.26 (32)
4.13 (105)
5.71 (145)
5.75 (146)
1.57 (40)
2 (50.80)
1.57 (40)
10.5 (267)
0.75 (19)
6.30 (160)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
19
High Current
Single Line
Feed-thru Filters
High current single line feed-thru filters from Spectrum
Control are ideal to meet broad frequency applications.
This series filters EMI/RFI with 150-500 Amp current with
AC and DC voltages. These filters are ideal for cellular
base stations, telephone switching stations and high
voltage power supply applications.
Features
20
Temperature Range:
Amps
Amps
Amps
Amps
Amps
Amps
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
10
12
12
14
16
18
mm
mm
mm
mm
mm
mm
-25C to 85C
50
Part
Number
60
Applications
Electrical Specifications
1.68F
40
0.04F
30
0.03F
0.02F
20
0.01F
10
0
0.01
0.1
1
10
Frequency (MHz)
100
Figure
Voltage Rating @
-40C to +85C
Current
Rating
Capacitance
Value
52-226-001
50VDC Max.
300 Amps
52-226-002
50VDC Max.
300 Amps
52-226-006
50VDC Max.
150 Amps
52-226-008
75VDC Max.
200 Amps
52-226-009
50VDC Max.
150 Amps
52-267-008
200VDC Max.
200 Amps
52-226-004
200 Amps
52-226-015
200 Amps
52-267-002
200 Amps
52-267-003
200 Amps
52-267-009
60 Amps
52-267-010
250 Amps
52-267-011
100 Amps
52-267-012
250VDC Max.
100 Amps
1000
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
High Current
Single Line
Feed-thru Filters
Mechanical Dimensions
Figure A
Figure B
4.67 (118.6)
4.20 (106.6)
4.669 (118.6)
4.196 (106.6)
1.221 (31.0)
1.220
(31.0)
1.811 (46.0)
1.498
(38.0)
1.811
(46.0)
2.441
(62.0)
1.587
(40.3)
1.496
(38.0)
1.586
(40.3)
2.441 (62.0)
.204 (5.2)
THRU (4x)
SCI 24-0058-4800
SCI 24-0058-4800
SCI 22-0833-0100
BRACKET ASSEMBLY
2.047 .02
(52.0 0.6)
2.598
(66.0)
MAX.
4.015 .02
(102.0 0.6)
.276 .016
(7 .4)
.063
(1.6)
.063
(1.6)
2.598
(66.0) MAX.
4.015 .02
(102.0 0.6)
SCI 24-0058-4800
DATE CODE
DATE CODE
.826 (21.0)
MIN. THRD.
LENGTH
1.50
(38.8)
45 CHAMFER
BOTH ENDS
.826 (21.0)
MIN. THRD. LENGTH
Figure C
1.25 (31.75)
Figure D
.874 (22.20) (2x)
5.393 (137.0)
5.039 (128.0)
.826 (21.0)
1.299
(33.0)
5.393 (137.0)
5.039 (128.0)
1.299
(33.0)
1.652 (42.0)
1.652 (42.0)
1.984
(49.5)
1.496
(38.0)
.204 .005
(5.2 .13) THRU
.807 (20.5)
2.0
.429 (10.9)
1.413 .002
(35.9 0.6)
2.598
(66.0) MAX.
.204 .005
(5.2 .13) THRU (4x)
.118 .005
(3.0 .13)
.118 .005
(3.0 .13)
1.295 .02
(32.9 0.6) (2x)
1.496
(38.0)
.807 (20.5)
1.984
(49.5)
1.295 .02
(32.9 0.6) (2x)
.063 (1.6)
.429 [10.9]
1.421 .012
[36.1 0.3]
1.89 0 .02
(48.0 0.6) MAX.
4.015 .02
(102.0 0.6)
2.717 .02
(89.0 .6)
.063 (1.6)
7.0
MIN.
DATE CODE
DATE CODE
Figure E
1.25
(31.75)
1.25
(31.75)
Figure F
.874 (22.20) (2x)
5.393 (137.0)
5.039 (128.0)
3.406
(86.5)
0.197
(5.00)
.826 (21.0)
1.299
(33.0)
3.799
(96.5)
0.197
(5.00)
1.801
(45.75)
0.197
(5.00)
1.652 (42.0)
1.984
(49.5)
1.496
(38.0)
.807 (20.5)
1.295 .02
(32.9 0.6) (2x)
.118 .005
(3.0 .13)
.204 .005
(5.2 .13) THRU (4x)
0.689
(17.5)
1.909 0.02
(48.5 0.5)
1.378
(35.0)
1.772
(45.0)
1.053 0.01
(26.75 0.3)
M10x1.5 6g STUDS
1.102 0.02
(28.0 .5)
.063 (1.6)
2.598
(66.0) MAX.
.961 0.02
(24.4 0.5)
4.015 .02
(102.0 .6)
3.976 0.02
(101.0 0.5)
.921 (23.4)
.047
(1.2)
SQ 52 - 226 - 004
200VDC 200A XXXX
1.890
(48.0) 1.969 0.02
(50.0 0.5)
21
High Current
Single Line
Feed-thru Filters
Figure G
Figure H
3.956
(100.5)
1.702
(43.25)
3.405
(86.5)
1.506
(38.25)
1.378
(35.0)
2.955 (75.0)
1.378
(35.0)
.964
(25.4)
1.023
(26.0)
1.929
(49.0)
5.516 (140.0)
PEM CLS-M4-1
(6 PLACES)
1.909 1.968
(48.5 50)
2.726 (69.2)
1.363 (34.6)
1.259
(32.0)
.078
(2.0)
MAX.
2.092 (53.10)
1.382 (35.08)
5.520 (140.10)
.248
(6.3)
1.889
(48.0)
1.52 (.060)
1.777 (45.10)
3.428 (87.00)
2.719 (69.00)
RED
BLACK
7.480 + .787/-0
(190.0 + 20.0/-0)
8.858 + .787/-0
(225.0 + 20.0/-0)
10.433 + .78/-0
(265.0 + 20.0/-0)
.984
(25.0)
Figure J
Figure K
3.799 (96.5)
4.807 (122.00)
3.406 (86.50)
1.801
(15.75)
2.403 (51.00)
.283 (7.2) (2x)
2.955 (75.0)
0.197 (5.0)
0.197 (5.0)
0.689 (17.5)
1.378 (35.00)
0.1850.004
(6x) (4.700.1)
2.285 (58.00)
.197
(5.0)
4.570 (116.00)
(MAX) 1.3780.004
(2x) (35.00.1)
5.516 (140.0)
2.726 (69.20)
1.772 (45.0)
1.9090.02
(48.50.5)
1.0530.01
(26.750.3)
1.363 (34.60)
0.6100.02
(15.50.5)
2.092 (53.10)
1.382 (35.08)
5.520 (140.10)
1.777 (45.10)
3.428 (87.00)
2.719 (69.00)
.080 (1.52)
.047 (1.2)
0.1180.02
(30.5)
3.190.16
(81.04)
.039 (1.00)
1.890 (48.0)
1.9690.02
(50.00.5)
22
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
High Current
Filtered Terminal Blocks
Features
Specifications
Applications
ELECTRICAL
Voltage rating:
Capacitance:
4.600 (116.8)
Dielectric
withstanding voltage: 1000VDC for 1 minute
Current rating:
60 Amps max per terminal
Typical Insertion Loss dB:
In 50 Ohm Circuit
1
5
10
50
8-32 THREADED
INSERTS (4X)
1.625
(41.3)
70
100
160
200
MHz......... 36
MHz......... 33
MHz......... 25
MHz......... 25
5.0 (127)
5.6 (142.2)
Part
Number
MHz....... 8
MHz....... 24
MHz....... 32
MHz....... 38
MECHANICAL
Center spacing:
Wire size:
Screw material:
Recommended PCB
hole diameter:
Molded material:
Tightening torque:
Terminal:
1.15 (29.1)
Number of
Terminals
in.
A
(mm)
in.
B
(mm)
in.
C
(mm)
52-1013-102
2x2
2.60
66.04
2.00
50.80
1.66
42.16
52-1013-103
2x3
3.35
85.09
2.75
69.85
2.41
61.21
52-1013-104
2x4
4.10
104.14
3.50
88.90
3.16
80.25
52-1013-105
2x5
4.85
123.19
4.25
107.95
3.91
99.31
52-1013-106
2x6
5.60
142.24
5.00
127.00
4.66
118.36
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-835-1650 Fax: 814-835-1651 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
23
Circuit Diagram
Applications
CY
L1
CX
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CY
Specifications
Model*
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-XXX-010-3-2
60-XXX-010-3-4
250VAC
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF 20%
0.50mA
3300pF 20%
60-XXX-010-5-4
0.35mA
250VAC
2200pF 20%
0.50mA
3300pF 20%
60-XXX-020-5-4
0.35mA
250VAC
2200pF 20%
0.50mA
3300pF 20%
60-XXX-030-5-4
0.35mA
250VAC
2200pF 20%
0.50mA
3300pF 20%
0.35mA
2200pF 20%
0.50mA
3300pF 20%
0.35mA
2200pF 20%
60-XXX-060-5-4
0.53mH
45C
.022uF 20%
0.26mH
45C
.01uF 20%
0.15mH
45C
.022uF 20%
.022uF 20%
.047uF 20%
250VAC
10A
250VAC
15A
24
30C
.022uF 20%
.047uF 20%
6A
60-XXX-060-5-2
60-BPR-150-3-11
1.2mH
.022uF 20%
.047uF 20%
60-XXX-060-3-2
60-XXX-100-5-2
30C
.022uF 20%
.047uF 20%
3A
60-XXX-030-5-2
60-XXX-100-3-2
2.4mH
.022uF 20%
.047uF 20%
60-XXX-030-3-2
60-XXX-060-3-4
30C
.022uF 20%
.047uF 20%
2A
60-XXX-020-5-2
60-XXX-030-3-4
6.0mH
.022uF 20%
.047uF 20%
60-XXX-020-3-2
60-XXX-020-3-4
Temperature
Rise (Max.)
.047uF 20%
1A
60-XXX-010-5-2
Inductance
(L1)
CX
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
0.807
(20.5)
120
Current (%)
100
.944 (24)
80
.846
(21.5)
60
1.476 (37.5)
(2x) .142
(3.6)
40
1.967
(50)
20
30
40
50
60
70
Ambient Temperature (C)
80
.157
(4)
1.10
(28)
1.181
(30)
1.573
(40)
20
* General tolerance
.012 (0.3)
90
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
50
80
70
70
60-BPX-010-5-X
60-BPX-010-5-X
Insertion Loss (dB)
60
50
40
60-BPX-020-5-X
30
60-BPX-030-5-X
20
60
50
40
60-BPX-020-5-X
30
60-BPX-030-5-X
20
10
10
0
0.1
0.2
0.5
10
20
0
0.1
50
0.2
0.5
10
20
50
60-BPX-060;-100
60-BPX-060;-100
80
80
70
70
Insertion Loss (dB)
60
60-BPX-060-5-X
50
40
30
60-BPX-100-5-X
20
60-BPX-060-X-4
60
50
60-BPX-060-X-2
40
60-BPX-100-X-2
30
20
10
10
0
0.1
Frequency (MHz)
Frequency (MHz)
50
Level
Meter
50
60-BPX-010;-020;-030
60-BPX-010;-020;-030
80
2.263 (57.5)
.252
(6.4)
0.2
0.5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
25
CY
L1
CX
Applications
Circuit Diagram
E
CY
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-BPF-010-3-2
60-BPF-010-3-4
250VAC
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF 20%
0.50mA
3300pF 20%
60-BPF-010-5-4
0.35mA
250VAC
2200pF 20%
0.50mA
3300pF 20%
60-BPF-020-5-4
30C
2.4mH
30C
1.2mH
30C
0.53mH
45C
.022uF 20%
.022uF 20%
.047uF 20%
60-BPF-030-3-2
0.35mA
250VAC
2200pF 20%
.022uF 20%
.047uF 20%
3A
60-BPF-030-5-2
0.50mA
3300pF 20%
60-BPF-030-5-4
.022uF 20%
.047uF 20%
60-BPF-060-3-2
60-BPF-060-3-4
6.0mH
.022uF 20%
.047uF 20%
2A
60-BPF-020-5-2
60-BPF-030-3-4
Temperature
Rise (Max.)
.047uF 20%
60-BPF-020-3-2
60-BPF-020-3-4
Inductance
(L1)
.022uF 20%
.047uF 20%
1A
60-BPF-010-5-2
CX
0.35mA
250VAC
2200pF 20%
.047uF 20%
6A
60-BPF-060-5-2
60-BPF-060-5-4
.022uF 20%
0.50mA
3300pF 20%
.022uF 20%
.047uF 20%
26
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
)
1.463 (37.2)
1.967 (50)
Temperature Characteristics
120
1.317
(33.5)
1.573 (40)
.885
(22.5)
.991
(25.2)
.590 (15)
2- .142
(3.6)
Current (%)
100
.047 (1.2)
.232 (5.9)
80
.024
(.6)
.
R4
.865
(22)
60
2- .142
(3.6)
1.573 (40)
40
.142
.059 (3.6)
(1.5)
.031 (.8)
1.070
(27.2)
1.180 (30)
* General
tolerance
.012 (.3)
.779 1.180
(19.8) (30)
.708
(18)
20
0
20
30
40
50
60
70
Ambient Temperature (C)
80
60-BPF
Fast-on
Terminals
90
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
60-BPF-010;-020
80
70
70
Insertion Loss (dB)
60-BPF-010-3-X
60
50
60-BPF-020-3-X
40
30
20
10
60
60-BPF-010-X-4
50
40
30
60-BPF-020-X-4
20
10
0.2
0.5
10
20
0
0.1
50
0.2
0.5
Frequency (MHz)
10
20
50
20
50
60-BPF-030;-060
60-BPF-030;-060
80
70
70
60
Frequency (MHz)
80
60-BPF-030-3-X
50
40
60-BPF-060-3-X
30
20
60
50
40
60-BPF-030-X-4
30
60-BPF-060-X-4
20
10
10
0
0.1
50
Level
Meter
50
60-BPF-010;-020
80
0
0.1
50
0.2
0.5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
10
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
27
Applications
Circuit Diagram
CY
L1
CX
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CY
4
L2
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-BHS-010-3-11
60-BHS-010-3-4
250VAC
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF 20%
0.50mA
3300pF 20%
60-BHS-010-5-4
0.35mA
250VAC
2200pF 20%
0.50mA
3300pF 20%
60-BHS-020-5-4
18.3uH
30C
2.4mH
18.3uH
30C
1.2mH
18.3uH
30C
.53mH
18.3uH
45C
0.1uF 20%
0.1uF 20%
.047uF 20%
60-BHS-030-3-11
0.35mA
250VAC
2200pF 20%
0.1uF 20%
.047uF 20%
3A
60-BHS-030-5-11
0.50mA
3300pF 20%
60-BHS-030-5-4
0.1uF 20%
.047uF 20%
60-BHS-060-3-11
60-BHS-060-3-4
6mH
0.1uF 20%
.047uF 20%
2A
60-BHS-020-5-11
60-BHS-030-3-4
Temperature
Rise (Max.)
.047uF 20%
60-BHS-020-3-11
60-BHS-020-3-4
Inductance
(L1)
(L2)
0.1uF 20%
.047uF 20%
1A
60-BHS-010-5-11
CX
0.35mA
250VAC
2200pF 20%
6A
60-BHS-060-5-11
60-BHS-060-5-4
0.1uF 20%
.047uF 20%
0.50mA
3300pF 20%
0.1uF 20%
.047uF 20%
28
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
1.967 (50)
1.573 (40)
120
.885
(22.5)
100
Current (%)
1.534 (39)
1.389
(35.3)
Temperature Characteristics
1.180
(30)
2- .142
(3.6)
80
1.180 (30)
.031 (.8)
.5
R4
.865
(22)
60
40
2- .142
(3.6)
1.573 (40)
.779 1.180
(19.8) (30)
20
0
20
30
40
50
60
70
Ambient Temperature (C)
80
90
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50
90
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
60-BHS-XXX-X-11
90
50
50
Level
Meter
50
60-BHS-XXX-3-11
80
80
Insertion Loss (dB)
60-BHS-010-X-11
70
60-BHS-020-X-11
60
50
40
60-BHS-030-X-11
30
60-BHS-060-X-11
70
60-BHS-010-3-11
60
50
60-BHS-020-3-11
40
60-BHS-030-3-11
30
60-BHS-060-3-11
20
20
10
10
0
0.1
0.2
0.5
10
20
0
0.1
50
0.2
0.5
90
60-BHS-XXX-X-4
90
10
20
50
60-BHS-XXX-3-4
80
60-BHS-010-X-4
70
80
60-BHS-020-X-4
60
50
40
60-BHS-030-X-4
30
60-BHS-060-X-4
70
60-BHS-010-3-4
60
50
60-BHS-020-3-4
40
60-BHS-030-3-4
30
60-BHS-060-3-4
20
20
10
10
0
0.1
Frequency (MHz)
Frequency (MHz)
0.2
0.5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
29
10-BPF Series
Features
Power Entry Modules
Circuit Diagram
CX
CY
Applications
CY
L1
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CX
CY
L1
CX
CY
2
CX
CX
L1
CY
CY
Specifications
Model
Rated
Rated
Voltage
Current
(@ 50/60Hz)
10-BPF-001-5-A
Leakage
Current
(Max.)
1A
120/250VAC
1.5mH
0.50mA
10-BPF-006-5-A
6A
4700pF
10A
10-BPF-010-5-D
Temperature
Rise
(Max.)
C
A
C
B
A
0.5mH
1.5mH
3300pF
0.01uF
0.5mH
1.5mH
3300pF
3300pF & 0.01uF
10-BPF-006-5-D
0.01uF
Figure
A
3.0mH
1
3A
10-BPF-003-5-C
10-BPF-010-5-A
Inductance Circuit
(L1)
Diagram
3300pF
10-BPF-003-5-A
10-BPF-006-5-C
CX
2200pF
10-BPF-001-5-C
10-BPF-003-5-D
Capacitance
CY
30C
30
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Figure B
M3 (2X)
1.6
(40)
M3 (2X)
2.0 (52)
2.0 (52)
1.1 (28.5)
+.01 -0.0
1.6 (40)
.007
1.4 (37)
2.8 (72)
1.25 (32)
Figure A
Figure C
.80 (20.5)
+.01 -0.0
1.4 (3.5) (2X)
2.3 (62)
1.9 1.6 1.2
(50) (40) (30)
.62 (16)
.82 (21)
.25
(6.5)
1.8 (46)
1.1 (28)
1.5 (37.5)
1.6 (40)
2.0 (51)
1.9 (50)
1.1 (27)
10-BPF Series
.07 (2)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
80
70
70
Insertion Loss (dB)
10-BPF-001-5-A
10-BPF-001-5-C
50
40
10-BPF-003-5-A
30
10-BPF-003-5-C
20
60
10-BPF-001-5-A
50
10-BPF-001-5-C
40
30
10-BPF-003-5-A
20
10-BPF-003-5-C
10
10
0
0.1
0.2
0.5
10
20
0
0.1
50
0.2
0.5
10
50
80
10-BPF-006-5-D
70
70
Insertion Loss (dB)
60
10-BPF-006-5-A
10-BPF-006-5-C
40
30
20
10-BPF-006-5-D
60
50
40
10-BPF-010-5-A
10-BPF-010-5-D
30
10-BPF-006-5-A
20
10-BPF-006-5-C
10-BPF-010-5-A
10
10
0
0.1
20
10-BPF-006;-010
10-BPF-006;-010
80
Frequency (MHz)
Frequency (MHz)
50
50
Level
Meter
50
10-BPF-001;-003
10-BPF-001;-003
80
60
50
10-BPF-010-5-D
0.2
0.5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
31
10-BPF Series
Features
Power Entry Modules
Circuit Diagram
Applications
L1
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CX
E
Specifications
Model
Rated
Rated
Voltage
Current
(@ 50/60Hz)
10-BPF-001-2-A
10-BPF-003-2-A 120/250VAC
10-BPF-006-2-A
1A
Leakage
Current
(Max.)
Capacitance
CX
5uA
0.01uF
Inductance
(L1)
Circuit
Diagram
Figure
Temperature
Rise
(Max.)
30C
3.0mH
10A
1.5mH
0.5mH
32
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
10-BPF Series
M3 (2X)
1.1 (28.5)
+.01 -0.0
1.6 (40)
.007
.80 (20.5)
+.01 -0.0
1.4 (3.5)
(2X)
0.807
(20.5)
1.1 (28)
1.5 (37.5)
.63 (16)
Common Mode
Normal Mode
1
3
Filter
2
4
1
3
Filter
2
4
Oscillator
50
50
Level
Meter
50
Oscillator
50
50
50
Level
Meter
50
10-BPF-001;-003;-006
80
70
70
Insertion Loss (dB)
10-BPF-001;-003;-006
80
60
2.0 (51)
.25
(6.5)
.82 (21)
10-BPF-001-2-A
50
10-BPF-003-2-A
40
30
20
60
50
40
30
10-BPF-006-2-A
10-BPF-001-2-A
20
10-BPF-006-2-A
10
0
0.1
10
0.2
0.5
Frequency (MHz)
10
20
50
0
0.1
10-BPF-003-2-A
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
33
Applications
Circuit Diagram
CY
L1
CX
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CY
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-SPL-010-3-2
60-SPL-010-3-3
250VAC
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF 20%
0.50mA
3300pF 20%
60-SPL-010-5-3
0.35mA
250VAC
2200pF 20%
0.50mA
3300pF 20%
60-SPL-020-5-3
30C
2.4mH
30C
1.2mH
30C
0.53mH
45C
22nF 20%
22nF 20%
33nF 20%
60-SPL-030-3-2
0.35mA
250VAC
2200pF 20%
.022uF 20%
3300pF 20%
3A
60-SPL-030-5-2
0.50mA
60-SPL-030-5-3
2200pF 20%
.033uF 20%
3300pF 20%
60-SPL-060-3-2
60-SPL-060-3-3
6.0mH
22nF 20%
33nF 20%
2A
60-SPL-020-5-2
60-SPL-030-3-3
Temperature
Rise (Max.)
33nF 20%
60-SPL-020-3-2
60-SPL-020-3-3
Inductance
(L1)
22nF 20%
33nF 20%
1A
60-SPL-010-5-2
CX
0.35mA
250VAC
2200pF 20%
6A
60-SPL-060-5-2
60-SPL-060-5-3
22nF 20%
33nF 20%
0.50mA
3300pF 20%
22nF 20%
33nF 20%
34
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
* General tolerance
.012 (.3)
120
.853
(21.7)
.838 (21.3)
100
Current (%)
R2
* Metal case
Tin Plated
80
.039 (1.0)
1.270 (32.3)
.047 (1.2)
1.274 (32.4)
.059 (1.5)
1.285 (32.5)
T :Panel Thickness
1.612 (41)
4.719 (120)*
.252 (6.4)
1.172 (29.8)
.236 (6)
60
Blue
UL 1015 AWG #18
1.397
(35.5)
40
Green/Yellow
Brown
20
20
30
40
50
60
70
Ambient Temperature (C)
80
Normal Mode
1
3
Filter
2
4
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
60-SPL-010-X-4
60-SPL-020-5-X
70
60-SPL-010-X-2
Insertion Loss (dB)
60-SPL-010-5-X
50
60-SPL-010-3-X
40
30
20
60
50
60-SPL-020-X-4
40
30
60-SPL-020-X-2
20
10
10
0
0.1
0.2
0.5
10
20
0
0.1
50
0.2
0.5
10
20
50
60-SPL-030;-060
60-SPL-030;-060
80
80
60-SPL-030-X-4
60-SPL-030-5-X
70
70
60-SPL-030-3-X
Insertion Loss (dB)
60
50
40
60-SPL-060-5-X
30
60-SPL-060-3-X
60
60-SPL-030-X-2
50
40
60-SPL-060-X-4
30
20
20
10
10
0
0.1
Frequency (MHz)
Frequency (MHz)
50
Level
Meter
50
80
60-SPL-020-3-X
50
60-SPL-010;-020
60-SPL-010;-020
80
70
90
Common Mode
60
Temperature Characteristics
60-SPL-060-X-2
0.2
0.5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
35
Circuit Diagram
Applications
CY
L1
CX
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CY
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-BPL-010-3-2
60-BPL-010-3-3
250VAC
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF 20%
0.50mA
3300pF 20%
60-BPL-010-5-3
0.35mA
250VAC
2200pF 20%
0.50mA
3300pF 20%
60-BPL-020-5-3
30C
2.4mH
30C
1.2mH
30C
0.53mH
45C
22nF 20%
22nF 20%
33nF 20%
60-BPL-030-3-2
0.35mA
250VAC
2200pF 20%
.022uF 20%
3300pF 20%
3A
60-BPL-030-5-2
0.50mA
60-BPL-030-5-3
2200pF 20%
.033uF 20%
3300pF 20%
60-BPL-060-3-2
60-BPL-060-3-3
6.0mH
22nF 20%
33nF 20%
2A
60-BPL-020-5-2
60-BPL-030-3-3
Temperature
Rise (Max.)
33nF 20%
60-BPL-020-3-2
60-BPL-020-3-3
Inductance
(L1)
22nF 20%
33nF 20%
1A
60-BPL-010-5-2
CX
0.35mA
250VAC
2200pF 20%
33nF 20%
6A
60-BPL-060-5-2
60-BPL-060-5-3
22nF 20%
0.50mA
3300pF 20%
22nF 20%
33nF 20%
36
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
.5
R4
.865
(22)
120
1.180 (30)
1.573 (40)
Current (%)
100
1.573 (40)
1.612 (41)
.830
(21.1)
1.172
(29.8)
1.967
(50)
20
30
40
50
60
70
Ambient Temperature (C)
80
GREEN/YELLOW
BROWN
90
Normal Mode
1
3
Filter
2
4
1
3
Filter
2
4
Oscillator
50
50
Level
Meter
50
Oscillator
50
50
50
Level
Meter
50
60-BPL-010;-020
60-BPL-010;-020
80
80
60-BPL-020-5-X
60-BPL-010-X-4
70
70
60-BPL-010-X-2
60
50
60-BPL-010-5-X
40
60-BPL-010-3-X
30
20
60-BPL-020-3-X
60
50
60-BPL-020-X-4
40
30
60-BPL-020-X-2
20
10
10
0.2
0.5
10
20
0
0.1
50
0.2
0.5
10
20
50
Frequency (MHz)
Frequency (MHz)
60-BPL-030;-060
60-BPL-030;-060
80
80
60-BPL-030-X-4
60-BPL-030-5-X
70
70
60-BPL-030-3-X
Insertion Loss (dB)
60
50
40
60-BPL-060-5-X
30
60-BPL-060-3-X
20
60
60-BPL-030-X-2
50
40
60-BPL-060-X-2
30
20
60-BPL-060-X-4
10
10
0
0.1
* General tolerance
.012 (0.3)
Common Mode
0
0.1
.236 (6)
UL1015 AWG # 18
BLUE
1.160
(29.5)
1.573
(40)
4.719 (120)*
.252 (6.4)
60
40
1.239 (31.5)
Panel cutout dimensions
mounts from front side
.944 (24)
2- .142
(3.6)
20
2- .118 (M3)
2- .130 (3.3)
80
R3
.885
(22.5)
.837
(21.3)
Temperature Characteristics
0.2
0.5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
37
Circuit Diagram
Applications
CY
L1
CX
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CY
Specifications
Model
Rated
Rated Leakage
Voltage
Current Current
(@ 50/60Hz)
(Max.)
10-BPL-006-5-B
CX
3300pF
0.01uF
1A
10-BPL-001-5-B
10-BPL-003-5-B
Capacitance
CY
250VAC
3A
Inductance Circuit
Diagram
(L1)
Figure
Temperature
Rise
(Max.)
30C
3.0mH
0.50mA
6A
1.5mH
0.5mH
38
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Figure A
M3 (2X)
1.1 (28.5)
+.01 -0.0
1.6 (40)
.007
.80 (20.5)
+.01 -0.0
1.4 (3.5)
(2X)
1.1 (28)
1.5 (37.5)
.63 (16)
2.0 (51)
.25
(6.5)
.82 (21)
Common Mode
Normal Mode
1
3
Filter
2
4
1
3
Filter
2
4
Oscillator
50
50
Level
Meter
50
Oscillator
50
80
10-BPL-001-5-B
70
70
10-BPL-003-5-B
10-BPL-001-5-B
50
Level
Meter
50
10-BPL-001;-003;-006
10-BPL-001;-003;-006
80
60
50
50
40
30
10-BPL-006-5-B
20
60
50
40
10-BPL-003-5-B
30
20
10-BPL-006-5-B
10
10
0
0.1
0.2
0.5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
39
CY
L1
CX
Applications
Circuit Diagram
E
CY
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
Specifications
Model*
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-XXX-010-3-2
60-XXX-010-3-4
250VAC
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF 20%
0.50mA
3300pF 20%
60-XXX-010-5-4
0.35mA
250VAC
2200pF 20%
30C
2.4mH
30C
1.2mH
30C
0.53mH
45C
.022uF 20%
0.26mH
45C
.01uF 20%
0.15mH
45C
.022uF 20%
.022uF 20%
.047uF 20%
2A
60-XXX-020-5-2
0.50mA
3300pF 20%
60-XXX-020-5-4
.022uF 20%
.047uF 20%
60-XXX-030-3-2
60-XXX-030-3-4
6.0mH
.022uF 20%
.047uF 20%
60-XXX-020-3-2
60-XXX-020-3-4
Temperature
Rise (Max.)
.047uF 20%
1A
60-XXX-010-5-2
Inductance
(L1)
CX
0.35mA
250VAC
.022uF 20%
2200pF 20%
.047uF 20%
3A
60-XXX-030-5-2
0.50mA
.022uF 20%
3300pF 20%
60-XXX-030-5-4
.047uF 20%
60-XXX-060-3-2
60-XXX-060-3-4
0.35mA
250VAC
2200pF 20%
.047uF 20%
6A
60-XXX-060-5-2
0.50mA
3300pF 20%
0.35mA
2200pF 20%
0.50mA
3300pF 20%
0.35mA
2200pF 20%
60-XXX-060-5-4
60-XXX-100-3-2
250VAC
10A
250VAC
15A
40
.022uF 20%
.047uF 20%
60-XXX-100-5-2
60-SPR-150-3-11
.022uF 20%
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
.963
(24.5)
120
.853
(21.7)
Current (%)
100
80
T: Panel Thickness
.039 (1.0)
1.270 (32.3)
.047 (1.2)
1.274 (32.4)
.059 (1.5)
1.285 (32.5)
1.418 (35.9)
.157
(4)
1.395
(35.5)
* Standard terminal
Fast-on tab #250
available as
SPR series
2.096 (53.3)
20
30
40
50
60
70
Ambient Temperature (C)
80
90
Common Mode
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
60-SPX-010;-020;-030
50
50
Level
Meter
50
60-SPX-010;-020;-030
80
80
70
70
60-SPX-010-5-X
60-SPX-010-X-4
Insertion Loss (dB)
60
50
40
60-SPX-020-5-X
30
60-SPX-030-5-X
20
10
60
50
60-SPX-020-X-4
40
60-SPX-030-X-4
30
20
10
0.2
0.5
10
20
0
0.1
50
0.2
0.5
10
20
50
Frequency (MHz)
Frequency (MHz)
60-SPX-060;-100
60-SPX-060;-100
80
80
70
70
Insertion Loss (dB)
60
60-SPX-60-5-X
50
40
30
60-SPX-100-5-X
20
10
0
0.1
Normal Mode
1
3
Filter
2
4
0
0.1
1.172
(29.8)
* General tolerance
.012 (0.3)
Solder Lug
2 X 3 hole
40
20
1.805 (45.9)
.252 (6.4)
60
W
Panel cutout dimensions
for 1.0t chassis
2.033 (51.7)
R2
Temperature Characteristics
60-SPX-060-X-4
60
50
60-SPX-060-X-2
40
60-SPX-100-X-2
30
20
10
0.2
0.5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
41
Fused Filtered
Power Entry Modules
For General Purpose Applications
64-65-BFF/64-65-BFS Series
Features
Fused Filtered
Power Entry Modules
L
L1
E
CY
E
CX
CY
Applications
Circuit Diagram
Specifications
Model*
64-XXX-020-3-11
64-XXX-020-5-11
64-XXX-020-3-12
64-XXX-020-5-12
64-XXX-040-3-11
64-XXX-040-5-11
64-XXX-040-3-12
64-XXX-040-5-12
64-XXX-060-3-11
64-XXX-060-5-11
64-XXX-060-3-12
64-XXX-060-5-12
65-XXX-020-3-11
65-XXX-020-5-11
65-XXX-020-3-12
65-XXX-020-5-12
65-XXX-040-3-11
65-XXX-040-5-11
65-XXX-040-3-12
65-XXX-040-5-12
65-XXX-060-3-11
65-XXX-060-5-11
65-XXX-060-3-12
65-XXX-060-5-12
Rated Voltage
(@ 50/60Hz)
250VAC
250VAC
250VAC
125VAC
125VAC
125VAC
Rated
Current
2A
4A
6A
2A
4A
6A
42
Leakage Current
(Max.)
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.20mA
0.25mA
0.20mA
0.25mA
0.20mA
0.25mA
0.20mA
0.25mA
0.20mA
0.25mA
0.20mA
0.25mA
Capacitance
CY
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
CX
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
Inductance
(L1)
Temperature
Rise (Max.)
6.5mH
40C
4.2mH
45C
1.6mH
45C
6.5mH
40C
4.2mH
45C
1.6mH
45C
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
* Substitute BFF or BFS for XXX
BFF - Fast-on terminals
BFS - Solder lug terminals
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Fused Filtered
Power Entry Modules
For General Purpose Applications
64-65-BFF/64-65-BFS Series
Dimensions
Temperature Characteristics
1.738 (44.2)
100
Current (%)
2.32 (59)
.098 (2.5)
1.101 (28)
Fuse cover
1.376
(35)
80
1.298
(33)
1.29
(32.8)
2 - .13 +.008
-.004
(2 - 3.3+0.2
-0.1)
Hole
60
1.416.008
(360.2)
0.252 (6.4)
1.14
(29)
1.616 (41.1)
40
Fast-on tab#250
t= .031 (0.8)
20
0.158
(4.0)
20
30
40
50
60
70
Ambient Temperature (C)
80
Fused Filtered
Power Entry Modules
64/65-BFF Series
120
* General Tolerance:
.020 (0.5)
* Metal Case
90
2.249 (L:57.2)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
50
50
Level
Meter
50
90
90
80
80
2 Amp
70
2 Amp
70
60
50
40
6 Amp
30
20
60
50
6 Amp
40
4 Amp
30
20
4 Amp
10
10
0
0.1
0.2
0.5
2
5
Frequency (MHz)
10
20
0
0.1
50
90
80
80
2 Amp
0.5
2
5
Frequency (MHz)
10
20
50
10
20
50
70
70
60
50
40
6 Amp
30
2 Amp
60
50
40
6 Amp
30
4 Amp
20
20
4 Amp
10
10
0
0.1
0.2
0.2
0.5
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
2
5
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
43
Fused Filtered
Power Entry Modules
Medical equipment
Electronic equipment
Digital equipment
Industrial equipment
Telecommunications equipment
Measuring and testing instruments
Personal computers
and peripherals
Circuit Diagrams
66/67-BFF(S)-XXX-0-X and
66/67-BFF(S)-XXX-4-X Filters
66/67-BFF(S)-XXX-1-X Filter
L
L1
R
L1
CX
E
CY
CX
E
E
CY
Specifications
Model*
66-XXX-020-1-11
66-XXX-020-1-12
66-XXX-020-0-11
66-XXX-020-4-11
66-XXX-020-0-12
66-XXX-020-4-12
66-XXX-040-1-11
66-XXX-040-1-12
66-XXX-040-0-11
66-XXX-040-4-11
66-XXX-040-0-12
66-XXX-040-4-12
66-XXX-060-1-11
66-XXX-060-1-12
66-XXX-060-0-11
66-XXX-060-4-11
66-XXX-060-0-12
66-XXX-060-4-12
67-XXX-020-1-11
67-XXX-020-1-12
67-XXX-020-0-11
67-XXX-020-4-11
67-XXX-020-0-12
67-XXX-020-4-12
67-XXX-040-1-11
67-XXX-040-1-12
67-XXX-040-0-11
67-XXX-040-4-11
67-XXX-040-0-12
67-XXX-040-4-12
67-XXX-060-1-11
67-XXX-060-1-12
67-XXX-060-0-11
67-XXX-060-4-11
67-XXX-060-0-12
67-XXX-060-4-12
Rated Voltage
(@ 50/60Hz)
Rated
Current
0.01mA
250VAC
2A
0.075mA
0.1mA
0.075mA
0.1mA
0.01mA
250VAC
4A
0.075mA
0.1mA
0.075mA
0.1mA
0.01mA
250VAC
6A
0.075mA
0.1mA
0.075mA
0.1mA
0.005mA
125VAC
2A
0.035mA
0.05mA
0.035mA
0.05mA
0.005mA
125VAC
4A
0.035mA
0.05mA
0.035mA
0.05mA
0.005mA
125VAC
6A
44
Leakage Current
(Max.)
0.035mA
0.05mA
0.035mA
0.05mA
Capacitance
CY
none
330pF
470pF
330pF
470pF
20%
20%
20%
20%
none
330pF
470pF
330pF
470pF
20%
20%
20%
20%
none
330pF
470pF
330pF
470pF
20%
20%
20%
20%
none
330pF
470pF
330pF
470pF
20%
20%
20%
20%
none
330pF
470pF
330pF
470pF
20%
20%
20%
20%
none
330pF
470pF
330pF
470pF
20%
20%
20%
20%
CX
0.1uF
0.22uF
0.1uF
Inductance
(L1)
Temperature
Rise (Max.)
6.5mH
40C
4.2mH
45C
1.6mH
45C
6.5mH
40C
4.2mH
45C
1.6mH
45C
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
* Substitute BFF or BFS for XXX
BFF - Fast-on terminals
BFS - Solder lug terminals
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
LOAD
Applications
LINE
LOAD
Fused Filtered
Power Entry Modules
LINE
66-67-BFF/66-67-BFS Series
Features
Fused Filtered
Power Entry Modules
66-67-BFF/66-67-BFS Series
Dimensions
Temperature Characteristics
1.738 (44.2)
2.32 (59)
.098 (2.5)
1.101 (28)
100
Current (%)
Fuse cover
1.376
(35)
80
1.298
(33)
60
1.416.008
(360.2)
40
1.29
(32.8)
2 - .13 +.008
-.004
(2 - 3.3+0.2
-0.1)
Hole
0.252 (6.4)
1.14
(29)
1.616 (41.1)
Fast-on tab#250
t= .031 (0.8)
20
0.158
(4.0)
20
30
40
50
60
70
Ambient Temperature (C)
80
2.249 (L:57.2)
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
90
90
80
80
70
70
Insertion Loss (dB)
50
60
2 Amp
40
30
60
2 Amp
50
30
0
0.1
0.2
0.5
10
1
2
5
Frequency (MHz)
10
20
0
0.1
50
80
80
70
70
Insertion Loss (dB)
90
60
2 Amp
50
0.2
0.5
2
5
Frequency (MHz)
40
30
10
0.2
0.5
20
50
60
50
2 Amp
40
30
4 Amp
20
20
6 Amp
6 Amp
4 Amp
10
0
0.1
6 Amp
6 Amp
4 Amp
4 Amp
40
20
20
10
50
Level
Meter
50
Normal Mode
1
3
Filter
2
4
50
* General Tolerance:
.020 (0.5)
* Metal Case
90
Common Mode
Fused Filtered
Power Entry Modules
66-67-BFF/66-67-BFS Series
120
10
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
2
5
Frequency (MHz)
10
20
50
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
45
64-65-BSF/64-65-SSF Series
Features
Applications
Computers and
peripheral equipment
Electronic equipment
Digital equipment
Measuring and testing instruments
Telecommunications equipment
Circuit Diagram
L
L
CY
CX
E
CX
R
CY
Specifications
Model*
Rated Voltage
(@ 50/60Hz)
Rated
Current
64-XXX-020-3-12
64-XXX-020-3-04
64-XXX-020-3-14
64-XXX-020-3-06
250VAC
2A
64-XXX-020-5-12
64-XXX-020-5-04
64-XXX-020-5-14
64-XXX-020-5-06
64-XXX-040-3-12
64-XXX-040-3-04
64-XXX-040-3-14
64-XXX-040-3-06
250VAC
4A
64-XXX-040-5-12
64-XXX-040-5-04
64-XXX-040-5-14
64-XXX-040-5-06
64-XXX-060-3-12
64-XXX-060-3-04
64-XXX-060-3-14
64-XXX-060-3-06
250VAC
6A
64-XXX-060-5-12
64-XXX-060-5-04
64-XXX-060-5-14
64-XXX-060-5-06
65-XXX-020-3-12
65-XXX-020-3-04
65-XXX-020-3-14
65-XXX-020-3-06
125VAC
2A
65-XXX-020-5-12
65-XXX-020-5-04
65-XXX-020-5-14
65-XXX-020-5-06
65-XXX-040-3-12
65-XXX-040-3-04
65-XXX-040-3-14
65-XXX-040-3-06
125VAC
4A
65-XXX-040-5-12
65-XXX-040-5-04
65-XXX-040-5-14
65-XXX-040-5-06
65-XXX-060-3-12
65-XXX-060-3-04
65-XXX-060-3-14
65-XXX-060-3-06
125VAC
6A
65-XXX-060-5-12
65-XXX-060-5-04
65-XXX-060-5-14
65-XXX-060-5-06
Note: Test Voltage 1500VAC one minute, line to ground
Insulation Resistance: 300 M min. at 500VDC
B(S) = Bolt-in terminals or (Snap-in terminals)
46
Leakage Current
(Max.)
CY
0.35mA
2200pF
Capacitance
CX1
0.22uF
0.47uF
0.22uF
0.50mA
3300pF
0.47uF
0.22uF
0.35mA
2200pF
0.47uF
0.22uF
0.50mA
3300pF
0.47uF
0.22uF
0.35mA
0.47uF
2200pF
0.22uF
0.50mA
0.47uF
0.22uF
0.35mA
2200pF
0.47uF
0.22uF
0.50mA
3300pF
0.47uF
0.22uF
0.35mA
2200pF
0.47uF
0.22uF
0.50mA
3300pF
0.47uF
0.22uF
0.35mA
0.47uF
2200pF
0.22uF
0.50mA
0.47uF
Voltage Drop: 1V max. at rated current
Weight: 130g
Inlet: Compatible with IEC-320
CX2
Inductance
(L1)
NONE
0.22uF
NONE
10.5mH
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
4.2mH
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
1.6mH
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
10.5mH
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
4.2mH
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
1.6mH
NONE
0.22uF
NONE
0.47uF
* Substitute BSF or SSF for XXX
BSF - Bolt-in switched and fused
SSF - Snap-in switched and fused
Temperature
Rise (Max.)
45C
45C
45C
45C
45C
45C
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Temperature
Temperature Characteristics
Characteristics
120
100
Current (%)
80
60
40
20
0
Dimensions
30
40
50
60
70
Ambient Temperature (C)
80
90
64/65-SSF Series
64/65-BSF Series
1.947 (49.5)
1.101 (28)
20
1.313 (33.4)
1.101 (28)
.248
(6.3)
.248
(6.3)
1.133
(28.8)
1.514 (38.8)
1.526 (38.8)
Fast-on tab #250
t= .031 (0.8)
2.556
(65)
2.556
(65)
2.340
(59.5)
2.348
(59.7)
2.348
(59.7)
2.340
(59.5)
.142
(3.6)
R .079
(2.0)
2 - .142
(3.6) Hole
R .059
(1.5)
t= .031 (0.8)
Panel cutout
dimension
mount from
back side
1.573 1.16.334
0
(40.0.2) (29.5 0.5)
0
Thickness of Panel
.031 (0.8t)
.039 (1.0t)
.047 (1.2t)
.059 (1.5t)
.071 (1.8t)
.079 (2.0t)
1.133
(28.8)
Fast-on Tab #250
2.273 (57.8)
1.573 (400.2)
2.273 (57.8)
1.16 +.02
-0
(29.5 +0.5
-0 )
A
2.430 (61.80.1)
2.446 (62.20.1)
2.462 (62.60.1)
2.470 (62.80.1)
2.473 (62.90.1)
2.477 (63.00.1)
* General Tolerance
.039 (1.0)
* Metal Case
2.399 (61)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50
50
1
3
Filter
2
4
50
Level
Meter
Oscillator
50
80
90
70
80
2 Amp
50
Level
Meter
50
64/65-B(S)SF-*-*-02(04,06)
90
60
50
40
4 Amp
30
6 Amp
20
70
60
50
2 Amp
40
4 Amp
30
10
6 Amp
20
0
0.1
0.2
0.5
2
5
Frequency (MHz)
10
20
0
0.1
50
0.5
2
5
Frequency (MHz)
10
20
50
20
50
100
80
90
70
80
Insertion Loss (dB)
2 Amp
60
50
40
4 Amp
30
6 Amp
20
70
60
4 Amp
6 Amp
50
2 Amp
40
30
10
0
0.1
0.2
64/65-B(S)SF-*-*-11(12,14)
90
50
20
0.2
0.5
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
2
5
Frequency (MHz)
10
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
47
Applications
Medical equipment
Industrial equipment
Telecommunications equipment
Measuring and testing instruments
Circuit Diagram
L
L
L1
R
CX1
CX2
CY1
E
LOAD
LINE
CY2
N
Specifications
Model*
66-XXX-020-0-12
66-XXX-020-0-04
66-XXX-020-0-14
66-XXX-020-0-06
66-XXX-020-1-12
66-XXX-020-1-04
66-XXX-020-1-14
66-XXX-020-1-06
66-XXX-020-4-12
66-XXX-020-4-04
66-XXX-020-4-14
66-XXX-020-4-06
66-XXX-040-0-12
66-XXX-040-0-04
66-XXX-040-0-14
66-XXX-040-0-06
66-XXX-040-1-12
66-XXX-040-1-04
66-XXX-040-1-14
66-XXX-040-1-06
66-XXX-040-4-12
66-XXX-040-4-04
66-XXX-040-4-14
66-XXX-040-4-06
66-XXX-060-0-12
66-XXX-060-0-04
66-XXX-060-0-14
66-XXX-060-0-06
66-XXX-060-1-12
66-XXX-060-1-04
66-XXX-060-1-14
66-XXX-060-1-06
66-XXX-060-4-12
66-XXX-060-4-04
66-XXX-060-4-14
66-XXX-060-4-06
.01mA NONE
0.47uF
0.22uF
0.1mA 470pF
0.47uF
0.22uF
.075mA 330pF
0.47uF
250
VAC
0.22uF
4A
.01mA NONE
0.47uF
0.22uF
.01mA 470pF
0.47uF
0.22uF
.075mA 330pF
0.47uF
0.22uF
6A
.01mA NONE
0.47uF
0.22uF
0.1mA 470pF
0.47uF
Rise
(Max.)
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF 10.5mH 40C
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
4.2mH
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
45C
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
1.6mH
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
48
Temp.
Induct.
(L1)
Model*
67-XXX-020-0-12
67-XXX-020-0-04
67-XXX-020-0-14
67-XXX-020-0-06
67-XXX-020-1-12
67-XXX-020-1-04
67-XXX-020-1-14
67-XXX-020-1-06
67-XXX-020-4-12
67-XXX-020-4-04
67-XXX-020-4-14
67-XXX-020-4-06
67-XXX-040-0-12
67-XXX-040-0-04
67-XXX-040-0-14
67-XXX-040-0-06
67-XXX-040-1-12
67-XXX-040-1-04
67-XXX-040-1-14
67-XXX-040-1-06
67-XXX-040-4-12
67-XXX-040-4-04
67-XXX-040-4-14
67-XXX-040-4-06
67-XXX-060-0-12
67-XXX-060-0-04
67-XXX-060-0-14
67-XXX-060-0-06
67-XXX-060-1-12
67-XXX-060-1-04
67-XXX-060-1-14
67-XXX-060-1-06
67-XXX-060-4-12
67-XXX-060-4-04
67-XXX-060-4-14
67-XXX-060-4-06
.005mA NONE
0.47uF
0.22uF
0.05mA 470pF
0.47uF
0.22uF
0.04mA 330pF
0.47uF
125
VAC
0.22uF
4A
.005mA NONE
0.47uF
0.22uF
0.05mA 470pF
0.47uF
0.22uF
0.04mA 330pF
0.47uF
0.22uF
6A
Weight: 130g
Inlet: Compatible with IEC-320
B(S) = Bolt-in terminals or (Snap-in terminals)
.005mA NONE
0.47uF
0.22uF
0.05mA 470pF
0.47uF
Temp.
Induct.
(L1)
Rise
(Max.)
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF 10.5mH 40C
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
4.2mH
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
45C
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
1.6mH
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Temperature Characteristics
120
100
Current (%)
80
60
40
20
20
30
40
50
60
70
Ambient Temperature (C)
80
90
Dimensions
66/67-BSF Series
1.947 (49.5)
1.101 (28)
66/67-SSF Series
.248
(6.3)
1.313 (33.4)
1.101 (28)
1.526 (38.8)
.248
(6.3)
1.133
(28.8)
1.514 (38.8)
t= .031 (0.8)
2.556
(65)
2.348
(59.7)
2.340
(59.5)
.142
(3.6)
2 - .142
(3.6) Hole
R .079
(2.0)
1.133
(28.8)
Fast-on Tab #250
2.273 (57.8)
1.573 (400.2)
2.340
(59.5)
2.348
(59.7)
R .059
(1.5)
2.399 (61)
Common Mode
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
80
80
70
70
Insertion Loss (dB)
90
60
2 Amp
40
30
20
2 Amp
50
40
30
4 Amp
6 Amp
10
10
0
0.1
0.2
0.5
2
5
Frequency (MHz)
10
20
0
0.1
50
90
80
80
70
70
Insertion Loss (dB)
90
60
2 Amp
50
40
30
20
2
5
Frequency (MHz)
10
20
50
2 Amp
60
50
40
4 Amp
30
6 Amp
10
10
0
0.1
0.5
20
6 Amp
4 Amp
0.2
50
Level
Meter
50
60
20
6 Amp
4 Amp
50
50
* General Tolerance
.039 (1.0)
* Metal Case
1.16 +.02
-0
(29.5 +0.5
-0 )
A
2.430 (61.80.1)
2.446 (62.20.1)
2.462 (62.60.1)
2.470 (62.80.1)
2.473 (62.90.1)
2.477 (63.00.1)
Normal Mode
1
3
Filter
2
4
Oscillator
50
Thickness of Panel
.031 (0.8t)
.039 (1.0t)
.047 (1.2t)
.059 (1.5t)
.071 (1.8t)
.079 (2.0t)
t= .031 (0.8)
Panel cutout
dimension
mount from
back side
1.573
1.16 +.02
-0
(40.0.2) (29.5 +0.5)
-0
2.273 (57.8)
0.2
0.5
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
2
5
Frequency (MHz)
10
20
50
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
49
68-BSF Series
Features
Dual fuse for European applications
Fuse holder and double pole power ON/OFF switch
provides a convenient/compact package
Suitable for products that must conform
to FCC and FTZ requirements
Meets over voltage category II of IEC 664
and complies with IEC 950
Metal case provides effective EMI shielding
IEC connector meets the safety standards of most
certifying agencies
Easy access fuse drawer
Flange-mounted
UL, CSA, and SEMKO approved
Designed to be in accordance with VDE 0565, part 3
Operating temperature: -25C to +85C
(including temperature rise, see graph on page 51)
Circuit Diagram
FUSE
L
L
L1
CY1
CX2
CX1
R1
L2
CY2
N
SW
Applications
Computers and peripheral equipment
Electronic equipment
Digital equipment
Measuring and testing instruments
Telecommunications equipment
Specifications
Model
Rated Voltage
(@ 50/60Hz)
68-BSF-020-3-01
Rated
Current
Leakage Current
(Max.)
CY1
Capacitance
CY2
CX1
2A
68-BSF-020-3-04
68-BSF-040-3-01
250VAC
4A
68-BSF-040-3-04
68-BSF-060-3-01
6A
68-BSF-060-3-04
0.35mA
2200pF
2200pF
CX2
0.1uF
0.1uF
0.22uF
0.22uF
0.1uF
0.1uF
0.22uF
0.22uF
0.1uF
0.1uF
0.22uF
0.22uF
Inductance
(L1)
Temperature
Rise (Max.)
10.5mH
4.2mH
45C
1.6mH
50
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Temperature Characteristics
1.947 (49.5)
1.101 (28)
.248
(6.3)
1.526 (38.8)
120
2.556
(65)
Current (%)
100
80
2.348
(59.7)
60
2 - .142
(3.6) Hole
20
30
40
50
60
70
Ambient Temperature (C)
80
90
Normal Mode
1
3
Filter
2
4
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
90
50
50
Level
Meter
50
100
90
70
80
Insertion Loss (dB)
80
60
50
40
4 Amp
30
2 Amp
6 Amp
20
70
4 Amp
60
50
2 Amp
40
30
10
0
0.1
t= .031 (0.8)
2.399 (61)
Common Mode
Oscillator
50
R .059
(1.5)
Panel cutout
dimension
mount from
back side
1.573
1.16 +.02
-0
(40.0.2) (29.5 +0.5)
-0
1.133
(28.8)
Fast-on Tab #250
2.273 (57.8)
1.573 (400.2)
40
20
2.340
(59.5)
.142
(3.6)
68-BSF Series
6 Amp
20
0.2
0.5
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
2
5
Frequency (MHz)
10
20
50
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
51
Features
Circuit Diagram
Applications
L1
CX1
CX1
Specifications
Model
Rated Voltage
(@ 50/60Hz)
61-MPC-010-1-11
61-MPC-016-1-11
61-MPC-025-1-11
61-MPC-036-1-11
Rated
Current
Leakage Current
(Max.)
Capacitance
CX1
CX2
1A
250VAC
1.6A
2.5A
3.6A
Inductance
(L1)
Temperature
Rise (Max.)
11mH
0.1mA
0.01uF
0.01uF
6.0mH
2.4mH
40C
1.2mH
52
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
4 .031 (.8)
.551 (14)
2
.767 (19.5)
.059 (1.5)
.590 (15)
1.239 (31.5)
.354
(9)
Temperature Characteristics
Common Mode
120
1
3
Filter
2
4
Oscillator
50
100
50
Level
Meter
50
1
3
Filter
2
4
(Test circuit 2)
Oscillator
50
Current (%)
Common
mode with
Y cap.
(Test circuit 1)
.767 (19.5)
50
Level
Meter
50
80
60
40
20
0
30
40
50
60
70
80
Ambient Temperature (C)
90
100
61-MPC
80
Y Cap
2 X 3300pF
70
Insertion Loss (dB)
61-MPC-010-1-11
Normal Mode
60
50
1
3
Filter
2
4
40
(Test circuit 3)
61-MPC-016-1-11
30
61-MPC-025-1-11
Oscillator
50
20
50
50
Level
Meter
50
61-MPC-036-1-11
10
0
0.1
0.2
0.5
2
5
Frequency (MHz)
10
20
50
61-MPC
61-MPC
80
80
70
70
60
61-MPC-010-1-11
50
40
30
61-MPC-016-1-11
20
61-MPC-036-1-11
0.5
61-MPC-010-1-11
40
61-MPC-016-1-11
30
61-MPC-025-1-11
20
10
10
0.2
50
61-MPC-036-1-11
61-MPC-025-1-11
0
0.1
60
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
53
60-BPP Series
Tested and found to be
IAW VDE 0565 Part 3
Features
CY
L1
CX
Applications
Circuit Diagram
CY
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-BPP-010-3-2
60-BPP-010-3-4
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF
0.50mA
3300pF
60-BPP-020-3-2
0.35mA
60-BPP-020-3-4
2200pF
0.50mA
3300pF
0.022uF
2.4mH
30C
0.022uF
0.047uF
250VAC
60-BPP-030-3-2
0.35mA
2200pF
0.022uF
0.047uF
3A
60-BPP-030-5-2
0.50mA
3300pF
0.047uF
60-BPP-060-3-2
0.022uF
0.35mA
2200pF
0.047uF
6A
60-BPP-060-5-2
60-BPP-060-5-4
0.50mA
3300pF
1.2mH
0.022uF
60-BPP-030-5-4
60-BPP-060-3-4
6.0mH
0.022uF
0.047uF
2A
60-BPP-020-5-2
60-BPP-030-3-4
Temperature
Rise (Max.)
0.047uF
60-BPP-010-5-4
60-BPP-020-5-4
Inductance
(L1)
0.022uF
0.047uF
1A
60-BPP-010-5-2
CX
0.53mH
45C
0.022uF
0.047uF
54
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
60-BPP Series
.098 (2.5)
120
Current (%)
100
1.463 (37.2)
1.967 (50)
1.317
(33.5)
1.573 (40)
.885
(22.5)
2- .142
(3.6)
80
.047 (1.2)
.232 (5.9)
60
.024
(.6)
.
R4
.865
(22)
40
2- .142
(3.6)
1.573 (40)
* General
tolerance
.012 (.3)
.142
.059 (3.6)
(1.5)
.031 (.8)
1.070
(27.2)
1.180 (30)
.779 1.180
(19.8) (30)
.708
(18)
20
0
.991
(25.2)
.590 (15)
20
30
40
50
60
70
Ambient Temperature (C)
80
90
Common Mode
Temperature Characteristics
60-BPP
PCB
Mounting
Type
Normal Mode
1
3
Filter
2
4
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
50
50
Level
Meter
50
60-BPP-010;-020
60-BPP-010;-020
80
80
70
70
60
60-BPP-010-3-X
50
60-BPP-020-3-X
40
30
20
60-BPP-010-X-4
50
40
30
60-BPP-020-X-4
20
10
10
0
0.1
60
0.2
0.5
10
20
0
0.1
50
0.2
0.5
Frequency (MHz)
10
20
50
20
50
60-BPP-030;-060
80
70
70
60
60-BPP-030;-060
80
60-BPP-030-3-X
50
40
60-BPP-060-3-X
30
20
10
0
0.1
Frequency (MHz)
60
50
40
60-BPP-030-X-4
30
60-BPP-060-X-4
20
10
0.2
0.5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
10
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
55
60-BHP Series
Tested and found to be
IAW VDE 0565 Part 3
Features
Circuit Diagram
CY
L1
Applications
CX
E
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CY
4
L2
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-BHP-010-3-11
Leakage Current
(Max.)
0.35mA
60-BHP-010-3-4
Capacitance
CY
2200pF20%
0.50mA
3300pF20%
60-BHP-010-5-4
0.35mA
60-BHP-020-3-4
2200pF20%
0.50mA
3300pF20%
0.35mA
2200pF20%
2.4mH
0.50mA
3300pF20%
60-BHP-030-5-4
30C
0.1uF20%
18.3 uH
0.1uF20%
.047uF20%
3A
60-BHP-030-5-11
1.2mH
0.1uF20%
.047uF20%
60-BHP-060-3-11
60-BHP-060-5-11
0.1uF20%
.047uF20%
250VAC
60-BHP-030-3-11
60-BHP-060-3-4
6mH
0.1uF20%
.047uF20%
2A
60-BHP-020-5-11
60-BHP-030-3-4
Temperature
Rise (Max.)
.047uF20%
60-BHP-020-3-11
60-BHP-020-5-4
Inductance
(L1)
(L2)
0.1uF20%
.047uF20%
1A
60-BHP-010-5-11
CX
0.35mA
2200pF20%
0.1uF20%
.047uF20%
6A
0.50mA
60-BHP-060-5-4
3300pF20%
0.53mH
45C
0.1uF20%
.047uF20%
56
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
60-BHP Series
120
.991
(25.2)
.590 (15)
2- .142
(3.6)
.5
2- .142
(3.6)
1.573 (40)
40
.059
(1.5)
.031 (.8)
1.070
(27.2)
.024
(.6)
R4
.865
(22)
.142
(3.6)
.047 (1.2)
.232 (5.9)
1.180 (30)
80
60
1.534 (39)
1.389
(35.3)
.885
(22.5)
100
Current (%)
.098
(2.5)
1.967 (50)
1.573 (40)
.779 1.180
(19.8) (30)
.708 (18)
20
20
30
40
50
60
70
Ambient Temperature (C)
80
90
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50
90
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
60-BHP-XXX-X-11
90
80
Insertion Loss (dB)
60-BHP-020-X-11
50
40
60-BHP-030-X-11
30
60-BHP-060-X-11
60-BHP-010-3-11
50
60-BHP-020-3-11
40
60-BHP-030-3-11
30
60-BHP-060-3-11
10
10
1
0.5
60-BHP-XXX-3-11
60
20
0.2
10
20
0
0.1
50
0.2
0.5
Frequency (MHz)
90
10
20
50
60-BHP-XXX-3-4
90
80
80
60-BHP-010-X-4
70
Frequency (MHz)
60-BHP-XXX-X-4
60-BHP-020-X-4
60
50
40
60-BHP-030-X-4
30
60-BHP-060-X-4
70
60-BHP-010-3-4
60
50
60-BHP-020-3-4
40
60-BHP-030-3-4
30
60-BHP-060-3-4
20
20
10
10
0
0.1
50
Level
Meter
50
70
20
0
0.1
50
80
60-BHP-010-X-11
70
60
60-BHP
PCB
Mounting
Type
Temperature Characteristics
0.2
0.5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
57
Circuit Diagram
Circuit 1
Applications
Circuit 2
Circuit 3
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
11-MPC-001-2-B
Leakage Current
(Max.)
Circuit
Diagram
Figure
5uA
1A
11-MPC-001-5-A
A
2
11-MPC-001-5-B
11-MPC-002-5-B
11-MPC-002-5-D
11-MPC-003-5-E
11-MPC-006-5-B
11-MPC-006-5-C
11-MPC-016-5-B
120/250VAC
2A
0.50mA
3A
6A
16A
Temperature Rise
(Max.)
3
2
0.2mA
B
D
30C
E
B
C
B
58
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Figure C
Figure B
0.6 0.9
(16) (25)
.30 (7.5)
2.0
0.9
(25).007 (51)
0.6
(16)
0.9 (25)
0.6
(15)
0.4
(10)
1.9 (30)
.30 (7.5)
2.5 (64)
Figure D
.79 (20)
1.1 (29)
0.9 (25)
1.7 (44)
0.6 (15)
.03
1.4 (36)
.60
(15)
.07
0.3 (8)
0.3 (8)
.45
(11.5) 1.4
(35)
1.1
(28)
.45
(11.5)
0.6
(16)
1.4 (36)
1.8 (45)
1.4 (35.5)
1.9 (49)
0.6 (15)
.07
1.1 (27)
Common Mode
.15
(4)
Normal Mode
1
3
Filter
2
4
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
50
Figure E
50
Level
Meter
50
11-MPC-001;-002
11-MPC-001;-002
80
80
11-MPC-002-5-D
70
70
11-MPC-001-5-A
60
11-MPC-001-2-B
50
40
11-MPC-002-5-D
30
20
11-MPC-001-5-B
60
11-MPC-001-5-B
50
11-MPC-001-2-B
40
30
20
11-MPC-001-5-A
11-MPC-002-5-B
10
10
11-MPC-002-5-B
0
0.1
0.2
0.5
10
20
0
0.1
50
0.2
0.5
10
20
50
Frequency (MHz)
Frequency (MHz)
11-MPC-003;-006;-016
11-MPC-003;-006;-016
80
80
70
70
60
11-MPC-006-5-C
11-MPC-003-5-E
50
11-MPC-006-5-B
40
30
11-MPC-016-5-B
20
60
11-MPC-016-5-B
50
11-MPC-003-5-E
40
30
11-MPC-006-5-C
20
11-MPC-006-5-B
10
0
0.1
10
0.2
0.5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
59
.629
(16.0)
1.220
(31.0)
1.573 (40.0)
.177 x .138 (4.5 x 3.5)
.994 (24.0)
.371
(9.4)
.371
(9.4)
1.527 (38.8)
.657
(16.7)
.374 (9.5)
.263 (6.7)
Applications
Circuit Diagrams
L
62-A*L
Series
62-AFL-010-3-11
62-AFC-010-3-11
62-AFL-010-5-11
62-AFC-010-5-11
62-AFL-016-3-11
62-AFC-016-3-11
62-AFL-016-5-11
62-AFC-016-5-11
62-AFL-030-3-11
62-AFC-030-3-11
62-AFL-030-5-11
62-AFC-030-5-11
62-AFL-045-3-11
62-AFC-045-3-11
62-AFL-045-5-11
62-AFC-045-5-11
62-AFL-060-3-11
62-AFC-060-3-11
62-AFL-060-5-11
62-AFC-060-5-11
Rated
Current
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF
0.50mA
3300pF
0.35mA
2200pF
0.50mA
3300pF
0.35mA
2200pF
0.50mA
3300pF
0.35mA
2200pF
0.50mA
3300pF
0.35mA
2200pF
0.50mA
3300pF
CX
CY1
CY2
Inductance
(L1)
Temperature
Rise (Max.)
11.0mH
1.6A
6.0mH
0.1uF
3.0A
4.5A
2.4mH
40C
1.0mH
6.0A
0.53mH
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max.
60
CX
1.0A
250VAC
CY2
* R= w/ Bleeder Resistor
F = w/o Bleeder Resistor
Specifications
Rated Voltage
(@ 50/60Hz)
CY1
L
62-A*C
Series
Model*
CX
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Temperature Characteristics
120
100
Current (%)
80
60
40
20
0
Normal
20 Mode
30
40
50
60
70
Ambient Temperature (C)
62-AL/62-AC Series
Common Mode
80
90
Normal Mode
1
3
Filter
2
4
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
50
50
Level
Meter
50
62-AFL-XXX-3-11
62-AFL-xxx-3-11
80
80
62-AFL-030-3-11
70
62-AFL-045-3-11
70
62-AFL-010-3-11
50
40
30
20
60
62-AFL-016-3-11
50
62-AFL-010-3-11
40
30
62-AFL-030-3-11
20
62-AFL-060-3-11
62-AFL-060-3-11
10
10
62-AFL-045-3-11
0
0.1
0.2
0.5
10
20
0
0.1
50
0.2
0.5
10
62-AFC-030-3-11
62-AFC-030-3-11
70
62-AFC-016-3-11
60
62-AFC-016-3-11
62-AFC-010-3-11
50
40
30
20
60
50
62-AFC-010-3-11
40
30
62-AFC-045-3-11
62-AFC-060-3-11
20
62-AFC-060-3-11
10
10
62-AFC-045-3-11
0
0.1
0.2
0.5
10
20
0
0.1
50
0.2
0.5
62-AFL-030-5-11
20
50
20
50
70
62-AFL-016-5-11
62-AFL-010-5-11
62-AFL-016-5-11
40
30
62-AFL-045-5-11
20
62-AFL-030-5-11
60
62-AFL-010-5-11
50
40
30
20
62-AFL-060-5-11
62-AFL-060-5-11
10
10
0
0.1
0.2
0.5
10
20
62-AFL-045-5-11
0
0.1
50
0.2
0.5
10
Frequency (MHz)
Frequency (MHz)
62-AFC-xxx-5-11
62-AFC-xxx-5-11
80
80
70
70
62-AFC-016-5-11
62-AFC-010-5-11
10
80
50
60
62-AFL-xxx-5-11
62-AFL-xxx-5-11
80
Frequency (MHz)
Frequency (MHz)
60
50
80
70
70
20
62-AFC-XXX-3-11
62-AFC-XXX-3-11
80
Frequency (MHz)
Frequency (MHz)
60
62-AFL-016-3-11
50
40
30
62-AFC-060-5-11
20
62-AFC-045-5-11
62-AFC-030-5-11
62-AFC-016-5-11
10
0
0.1
0.2
0.5
Frequency (MHz)
10
20
62-AFC-030-5-11
60
62-AFC-010-5-11
50
40
30
20
62-AFC-045-5-11
10
50
0
0.1
62-AFC-060-5-11
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
61
Features
Applications
Circuit Diagrams
L1
62-PQF-020-5-11
62-PQF-020-5-12
62-PPF-020-5-11
62-PPF-020-5-12
62-PQF-030-5-11
62-PQF-030-5-12
62-PPF-030-5-11
62-PPF-030-5-12
62-PQF-060-5-11
62-PQF-060-5-12
62-PPF-060-5-11
62-PPF-060-5-12
62-PRF-010-5-11
62-PRF-010-5-12
62-PRF-020-5-11
62-PRF-020-5-12
62-PRF-030-5-11
62-PRF-030-5-12
Rated Voltage
(@ 50/60Hz)
CY
CY
CY
CX
CY
L1
L1
62-PRF*
Series
CX
CY
CY
Specifications
Model
L1
62-PPF*
Series
CX
62-PQF*
Series
Rated
Current
Leakage Current
(Max.)
Capacitance
CY
2A
3A
0.50mA
250VAC
3300pF
6A
1A
2A
3A
CX
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
Inductance
(L1)
Temperature
Rise (Max.)
15mH
8mH
30C
2.1mH
486uH
181uH
97uH
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. (except 62-PRF-010-5-11) at rated current
62-PRF-010-5-11: 1.5V max. at rated current
Weight: 62-PPF & PQF Series: 2.11 ounces (60 grams)
62-PRF Series: 1.76 ounces (50 grams)
62
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Normal Mode
120
1
3
Filter
2
4
Current (%)
100
Oscillator
50
80
50
50
Level
Meter
50
60
40
62-PQF Series
80
20
70
20
30
40
50
60
70
Ambient Temperature (C)
80
90
50
40
62-PQF-020-5-11
30
62-PQF-060-5-12
20
62-PQF-060-5-11
10
0
0.1
.786
(20)
0.2
0.5
10
20
50
10
20
50
10
20
50
62-PPF Series
2.006 (51)
1.947 (49.5)
.354
(9)
Frequency (MHz)
1.573 (40)
.354
(9)
62-PQF-020-5-12
60
80
1.265 (32)
.590 (15)
Common Mode
70
.904
(23)
60
50
62-PPF-020-5-12
40
62-PPF-020-5-11
30
62-PPF-060-5-12
20
62-PPF-060-5-11
10
1
3
Filter
2
4
Oscillator
50
0
0.1
50
Level
Meter
50
0.2
0.5
Frequency (MHz)
62-PRF Series
62-P(P/Q/R)F Series
80
80
70
60
60
62-P(Q/P)-060-5-11
70
50
40
30
62-P(Q/P)-020-5-11
20
50
62-PRF-010-5-11
40
62-PRF-010-5-12
30
62-PRF-030-5-12
20
62-P(Q/P)-030-5-11
62-PRF-030-5-11
10
0
0.1
10
0.2
0.5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
63
Features
Circuit Diagram
3
CY
L1
CX
CX
Applications
Power Line Filters
Digital equipment
Personal computers and peripherals
Measuring instruments
Medical equipment
Factory automation equipment
CY
4
Specifications
Model
Rated Voltage
(@ 50/60Hz)
62-PML-015-3-11
Rated
Current
1.5A
62-PML-015-5-11
62-PML-030-3-11
62-PML-030-5-11
62-PML-050-3-11
62-PML-050-5-11
62-PML-100-5-11
3A
250VAC
5A
10A
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF
0.50mA
3300pF
0.35mA
2200pF
0.50mA
3300pF
0.35mA
2200pF
0.50mA
3300pF
0.50mA
3300pF
CX
Inductance
(L1)
Temperature
Rise (Max.)
10.0mH
4.3mH
30C
0.1uF
2.4mH
2.2mH
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 62-PML-015 Series: 3.06 ounces (87 grams)
62-PML-030 Series: 3.17 ounces (90 grams)
62-PML-050 Series: 3.28 ounces (93 grams)
Discharge time: 0.4 sec. max.
64
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Temperature Characteristics
WH
G/Y
120
BK
1.219
(31)
.786
(20) 1.966
(50)
WH
PVC
Insulated wire
AWG # 20 UL1015
100
.629
(16)
.944 (24)
80
60
.395 (10)
.395
(10)
5.112* (130)
40
5.112* (130)
20
20
30
40
50
60
70
80
1.856 (47.2)
90
Current (%)
1.573
(40)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
50
50
Level
Meter
50
80
70
62-PML
90
40
30
62-PML-050-5-21
20
10
0
0.1
62-PML
80
62-PML-030-5-21
50
62-PML-015-5-21
60
70
60
62-PML-050-5-11
50
40
62-PML-030-5-11
30
62-PML-015-5-11
20
0.2
0.5
10
20
50
10
Frequency (MHz)
0
0.1
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
65
Circuit Diagram
Circuit 1
Circuit 2
Applications
Digital equipment
Personal computers and peripherals
Measuring instruments
Medical equipment
Factory automation equipment
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
12-PML-001-2-A
1A
12-PML-002-2-A
2A
12-PML-006-2-A
6A
12-PML-010-2-A
12-PMF-001-2-B
120/250VAC
10A
1A
12-PMF-002-2-B
2A
12-PMF-006-2-B
6A
12-PML-001-2-C
1A
Leakage Current
(Max.)
Circuit
Diagram
Figure
5uA
Temperature Rise
(Max.)
30C
2
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Discharge time: 0.4 sec. max.
66
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Figure C
.31 (8)
1.5
(39)
1.9
(49)
1.2
(30)
1.25 (32)
1.6 (42)
1.9 (48)
1.7 (44)
.78 (20)
.78 (20)
Figure B
.14 (3.8) (2X)
1.2
(30)
1.7 (44)
.79 (20)
2.2 (56)
2.4 (61)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
12-PML-001;-002;-006;-010
50
50
Level
Meter
50
12-PML-001;-002;-006;-010
80
80
70
70
12-PML-002-2-A
12-PML-006-2-A
60
12-PML-001-2-A
12-PML-001-2-A
12-PML-006-2-A
50
40
30
20
12-PML-002-2-A
10
0
0.1
50
40
30
20
12-PML-010-2-A
10
12-PML-010-2-A
0.2
60
0.5
10
20
0
0.1
50
0.2
0.5
Frequency (MHz)
70
70
12-PMF-001-2-B
12-PMF-002-2-B
50
40
30
20
12-PMF-006-2-B
10
0
0.1
0.5
Frequency (MHz)
10
12-PMF-001-2-B
20
50
20
50
12-PMF-002-2-B
60
50
11-PML-001-2-C
40
30
20
12-PMF-006-2-B
10
11-PML-001-2-C
0.2
10
12-PMF-001;-002;-006;-010
80
12-PMF-001;-002;-006;-010
80
60
Frequency (MHz)
0
0.1
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
67
Features
Circuit Diagram
CY
CX
CX
R
Applications
L1
CY
Digital equipment
Office automation equipment, such as copy
and fax machines
Computers and peripherals
Instrumentation and controls
Specifications
Model*
Rated Voltage
(@ 50/60Hz)
62-LMB-030-5-11
Rated
Current
Leakage Current
(Max.)
Capacitance
CX
Inductance
(L1)
3A
0.1uF
14mH
5A
7.0mH
8A
.22uF
4.2mH
10A
.33uF
2.2mH
CY
Temperature
Rise (Max.)
62-LMF-030-5-11
62-LMB-050-5-11
62-LMF-050-5-11
62-LMB-080-5-11
62-LMF-080-5-11
62-LMB-100-5-11
250VAC
0.50mA
62-LMF-100-5-11
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Discharge time: 0.4 sec. max.
Weight: 5.3 ounces (150 grams)
68
45C
3300pF
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Temperature Characteristics
120
100
Current (%)
80
60
40
20
30
40
50
60
70
Ambient Temperature (C)
80
90
62-LMF
62-LMB
.708
(18.0)
20
1.10
(28.0)
1.97
(50.0)
.66
(16.8)
.66
(16.8)
.255
(6.5)
.61
(15.5)
1.10
(28.0)
.708
(18.0)
.61
(15.5)
1.97
(50.0)
2 - 4.8
.255
(6.5)
5-M4
2.39
(60.7 0.5)
1.97
(50.0)
1.22
(31.0)
2.79
(70.9)
.61
(15.5)
1.97
(50.0)
2.79
(70.9)
.61
(15.5)
Fast-on Tabs #250
.031 (0.8) t
2 - .188
(4.8)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50
1.22
(31.0)
2.39
(60.7 0.5)
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
50
50
Level
Meter
50
90
90
80
80
70
62-LM-030-5-11
62-LM-030-5-11
62-LM-050-5-11
60
50
40
30
62-LM-100-5-11
20
0.5
60
50
40
62-LM-100-5-11
30
62-LM-080-5-11
10
10
0.2
70
20
62-LM-080-5-11
0
0.1
62-LM-050-5-11
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
69
Features
Circuit Diagram
CY
L1
CX
CX
R
CY
Applications
Power Line Filters
Digital equipment
Computers and peripherals
Measuring instruments
Medical equipment
Equipment requiring very high impulse attenuation
Factory automation equipment
Industrial equipment such as UPS, inverters
and converters
Telecommunications equipment
Office automation equipment, such as copy
and fax machines
Specifications
Model*
Rated Voltage
(@ 50/60Hz)
62-PMB-050-5-11
Rated
Current
Leakage Current
(Max.)
Capacitance
CX
Inductance
(L1)
5A
0.1uF
14mH
8A
7.0mH
.22uF
4.2mH
CY
Temperature
Rise (Max.)
62-PMF-050-5-11
62-PMB-080-5-11
62-PMF-080-5-11
62-PMB-100-5-12
62-PMF-100-5-12
62-PMB-150-5-13
62-PMF-150-5-13
250VAC
10A
2.2mH
35C
1.8mH
45C**
.33uF
20A
70
3300pF
15A
62-PMB-200-5-13
62-PMF-200-5-13
0.50mA
30C
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
62-PMF
3.291 (83.7)
B
C
Fast-on tab
#250
2.937 (74.7)
Temperature Characteristics
1.258
(32)
120
2 .197 (5)
.610
(15.5)
.315
(8)
62-PMB
80
3.291 (83.7)
2.937 (74.7)
5 .157
(M4)
60
2 .197
(5)
1.258
(32)
1.998
(50.8)
40
MODEL
30
40
50
60
70
Ambient Temperature (C)
80
90
Common Mode
62-PMF/PMB-050-080
1.258 .786
(32) (20)
0
(0)
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
62-PMB-050-6
50
50
Level
Meter
50
62-PMB-050-6
R2
R1
S1 Filter S2
T1
T2
50
Level
Meter
Oscillator
50
90
90
80
80
50
50
50
R2
R1
S1 Filter S2
T1
T2
Oscillator
50
60
50
40
62-PMB-100-5-12
30
62-PMB-150-5-13
20
62-PMF-050-5-11
70
60
50
40
62-PMF-150-5-13
30
20
62-PMB-200-5-13
10
50
Level
Meter
62-PMB-200-5-13
62-PMB-050-5-11
62-PMB-080-5-11
0
0.1
62-PMF/PMB-100-200
Normal Mode
1
3
Filter
2
4
Oscillator
50
.315
(8)
50
20
50
70
.649
(16.5)
2.497 (63.5)
.649
(16.5)
20
.610
(15.5)
2.497 (63.5)
50
Current (%)
100
1.998
(50.8)
62-PMF-080-5-11
10
0.2
0.5
Frequency (MHz)
10
20
50
0
0.1
62-PMF-100-5-12
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
71
Circuit Diagram
Circuit 1
Circuit 2
Circuit 3
Circuit 4
Circuit 5
Circuit 6
Applications
Digital equipment
Computers and peripherals
Measuring instruments
Medical equipment
Equipment requiring very high impulse attenuation
Factory automation equipment
Industrial equipment such as UPS, inverters
and converters
Telecommunications equipment
Office automation equipment, such as copy
and fax machines
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage Current
(Max.)
Circuit
Diagram
Figure
12-PMF-001-5-A
1A
12-PMF-002-5-B
2A
12-PMF-003-5-A
3A
12-PMF-003-5-B
12-PMF-006-5-A
6A
12-PMF-006-5-C
12-PMF-006-5-D
12-PMF-010-5-A
12-PMF-010-5-C
12-PMF-015-5-C
12-PMF-015-5-E
120/250VAC
10A
15A
20A
12-PMF-020-5-E
30C
C
E
12-PMF-020-5-C
12-PMF-020-5-D
0.5mA
Temperature Rise
(Max.)
C
D
E
72
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Figure A
Figure B
.14 (3.8)
2 .34 (8.8)
1.2
(30)
2.4 1.8
(62) (46)
2.1
(54)
1.7 (44)
2.2 (56)
.78 (20)
3.2 (81)
1.25 (32)
2.4 (62)
.86 (22)
Figure D
Figure C
Figure E
.41 (10.5)
2 .17 (8.8)
2-
.18 (4.8)
2.0
(52)
2.0 (52)
2.4 (63)
1.4 (37)
2.5 3.3
(64) (85)
2.9
(74)
3.2 (82)
Normal Mode
1
3
Filter
2
4
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
12-PMF-001;-002;-003;-006
12-PMF-006-5-C
12-PMF-001-5-A
70
12-PMF-001-5-A
12-PMF-006-5-A
12-PMF-002-5-B
12-PMF-003-5-B
12-PMF-006-5-A
40
12-PMF-003-5-A
12-PMF-006-5-C
30
20
12-PMF-006-5-D
60
12-PMF-006-5-D
50
40
30
12-PMF-003-5-B
20
12-PMF-003-5-A
10
10
0
0.1
12-PMF-002-5-B
0.2
0.5
10
20
0
0.1
50
0.2
0.5
Frequency (MHz)
12-PMF-001;-002;-003;-006
12-PMF-006-5-A
40
12-PMF-003-5-A
12-PMF-006-5-C
30
20
12-PMF-003-5-B
50
12-PMF-015-5-E
60
12-PMF-020-5-C
50
40
12-PMF-010-5-A
30
20
12-PMF-020-5-D
12-PMF-020-5-E
12-PMF-006-5-D
10
10
0.5
20
12-PMF-010-5-C
12-PMF-002-5-B
0.2
10
70
12-PMF-001-5-A
0
0.1
12-PMF-010;-015;-020
80
70
50
Frequency (MHz)
80
60
50
Level
Meter
50
80
50
50
12-PMF-001;-002;-003;-006
80
70
1.4 (36)
3.1 (80)
Common Mode
60
2.0 (51)
1.1 (28)
2.9 (74)
1.7 (44)
Frequency (MHz)
10
20
50
0
0.1
12-PMF-015-5-C
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
73
Circuit Diagram
L1
CX
CY
CX
CY
L1
Applications
Digital equipment
Computers and peripherals
Measuring instruments
Medical equipment
Equipment requiring very high impulse attenuation
Factory automation equipment
Industrial equipment such as UPS, inverters
and converters
Telecommunications equipment
Office automation equipment, such as copy
and fax machines
Specifications
Model
Rated Voltage
(@ 50/60Hz)
62-PMB-300-5-14
Rated
Current
CY
Capacitance
CX
0.50mA
3300pF
.47uF
40A
Inductance
(L1)
Temperature
Rise (Max.)
1.6mH
30A
250VAC
62-PMB-400-5-14
Leakage Current
(Max.)
45C
0.8mH
74
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
4.13 (105)
3.74 (95.08)
3.15 (80)
0.511
(13.0)
3.70 (94)
3.85 (98)
1.022
(26.0)
5.591 (142.00)
2.049 (52.0)
Common Mode
Normal Mode
1
2
50 ohm
LEVEL
METER
50 ohm
90
90
80
80
70
70
60
62-PMB-400-5-14
40
30
20
10
0
0.1
50 ohm
LEVEL
METER
50 ohm
60
50
62-PMB-300-5-14
40
30
20
62-PMB-300-5-14
OSCILLATOR
50 ohm
50 ohm
50
3
FILTER
FILTER
2
OSCILLATOR
50 ohm
3.03 (770.5)
62-PMB-400-5-14
10
0.2
0.5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
75
Circuit Diagram
L1
CX
CY
CX
R
L1
Applications
CY
4
Digital equipment
Computers and peripherals
Measuring instruments
Medical equipment
Equipment requiring very high impulse attenuation
Factory automation equipment
Industrial equipment such as UPS, inverters
and converters
Telecommunications equipment
Office automation equipment, such as copy
and fax machines
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
12-PMB-025-5-A
25A
12-PMB-030-5-A
30A
12-PMB-035-5-B
12-PMB-050-5-B
120/250VAC
Leakage Current
(Max.)
100A
120A
Temperature Rise
(Max.)
A
1
50A
12-PMB-120-8-C
Figure
0.5mA
35A
12-PMB-100-8-C
Circuit
Diagram
1.0mA
30C
76
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Figure B
M4 THREAD (10X)
Figure C
0.2 (6.3)
0.5 (4.5)
2.0
(24) .03
2.0
(52)
M8 THREAD (4X)
0.8 (22)
.03
1.4 (37) MAX
1.9 (50)
2.0 (51)
3.9 (98.5)
1.5 (38.5)
3.1 (80)
4.7 (120)
7.0 (180)
5.3 (135)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
50
50
Level
Meter
50
12-PMB-025;-030;-035
12-PMB-025;-030;-035
80
80
70
70
60
12-PMB-035-5-B
12-PMB-025-5-A
50
40
30
12-PMB-035-5-B
20
60
50
12-PMB-025-5-A
40
12-PMB-030-5-A
30
20
12-PMB-030-5-A
10
10
0
0.1
0.2
0.5
10
20
0
0.1
50
0.2
0.5
10
20
50
Frequency (MHz)
Frequency (MHz)
12-PMB-050;-100;-120
12-PMB-050;-100;-120
80
80
70
70
12-PMB-050-5-B
12-PMB-100-8-C
60
50
40
30
12-PMB-050-5-B
20
60
50
12-PMB-120-8-C
40
12-PMB-100-8-C
30
20
12-PMB-120-8-C
10
0
0.1
10
0.2
0.5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
77
Circuit Diagram
Circuit 1
Applications
Circuit 2
Digital equipment
Computers and peripherals
Measuring instruments
Equipment requiring very high impulse attenuation
Factory automation equipment
Industrial equipment such as UPS, inverters and converters
Telecommunications equipment
Specifications
Model
12-PMF-006-DC-C
12-PMF-010-DC-C
12-PMF-015-DC-C
12-PMF-020-DC-C
12-PMF-025-DC-D
12-PMB-025-DC-F
12-PMB-030-DC-F
12-PMB-035-DC-F
12-PMB-040-DC-F
12-PMB-040-DC-B
12-PMB-050-DC-B
12-PMB-060-DC-B
12-PMB-080-DC-G
12-PMB-080-DC-C
12-PMB-100-DC-C
12-PMB-120-DC-C
12-PMB-140-DC-C
12-PMB-180-DC-E
12-PMB-200-DC-E
12-PMB-260-DC-E
Rated Voltage
(@ 50/60Hz)
Rated
Current
Circuit
Diagram
6A
10A
15A
20A
30A
35A
Figure
Temperature Rise
(Max.)
25A
1
40A
48/250
VDC
50A
60A
80A
100A
120A
140A
180A
200A
260A
78
Circuit 3
30C
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Figure A
Figure C
Figure D
Figure E
Figure F
Figure G
1.9 (50)
.003
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
12-PMF-006;-010;-015;-020;-025
80
12-PMF-006;-010;-015;-020;-025
12-PMF-025-DC-D
70
60
12-PMF-010-DC-C
50
12-PMF-025-DC-D
40
30
12-PMF-015-DC-C
20
12-PMF-020-DC-C
10
60
12-PMF-020-DC-C
50
12-PMF-010-DC-C
40
12-PMF-015-DC-C
30
12-PMF-006-DC-C
20
10
0.2
0.5
10
20
0
0.1
50
0.2
0.5
Frequency (MHz)
12-PMB-080-DC-G
12-PMB-080-DC-C
12-PMB-025-DC-F
12-PMB-030-DC-F
12-PMB-035-DC-F
12-PMB-040-DC-F
20
50
40
12-PMB-180-DC-E
12-PMB-200-DC-E
12-PMB-260-DC-E
30
20
12-PMB-040-DC-B
12-PMB-050-DC-B
12-PMB-060-DC-B
12-PMB-100-DC-C
12-PMB-120-DC-C
12-PMB-140-DC-C
10
0.2
0.5
Frequency (MHz)
70
Insertion Loss (dB)
10
80
50
0
0.1
Frequency (MHz)
80
70
50
Level
Meter
50
80
12-PMF-006-DC-C
70
0
0.1
50
10
20
60
40
12-PMB-080-DC-G
12-PMB-080-DC-C
30
20
10
50
12-PMB-025-DC-F
12-PMB-030-DC-F
12-PMB-035-DC-F
12-PMB-040-DC-F
50
0
0.1
12-PMB-180-DC-E
12-PMB-200-DC-E
12-PMB-260-DC-E
0.2
0.5
12-PMB-040-DC-B
12-PMB-050-DC-B
12-PMB-060-DC-B
12-PMB-100-DC-C
12-PMB-120-DC-C
12-PMB-140-DC-C
5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
79
Circuit Diagram
62-MMF-XXX-7-11
L1
CX
Applications
CX
CY
CX
CY
Digital equipment
Personal computers and peripherals
Measuring instruments and medical equipment
Telecommunications equipment
Equipment requiring very high noise attenuation
L1
CY
CY
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage Current
(Max.)
CY1
Capacitance
CY2
CX
Inductance
(L1) (2X)
Temperature
Rise (Max.)
62-MMF-030-7-11
250VAC
3A
.7mA
3300pF
1000pF
0.1uF
3.7mH
30C
62-MMF-050-7-11
250VAC
5A
.7mA
3300pF
1000pF
0.1uF
2.9mH
30C
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Leakage current: 0.7 mA max.
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
Weight: 6.0 ounces (170 grams)
80
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
3.291 (83.7)
120
.786 (20)
.315
(8)
Fast-on tab
#250
2.937 (74.7)
Current (%)
100
80
.315
(8)
2 .197 (5)
1.258
(32)
1.998
(50.8)
60
.610
(15.5)
40
.610
(15.5)
2.497 (63.5)
1.258 (32)
20
20
30
40
50
60
70
80
90
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
90
80
80
70
70
60
62-MMF-050-7-11
50
62-MMF-030-7-11
40
30
20
60
62-MMF-050-7-11
50
62-MMF-030-7-11
40
30
20
10
0
0.1
50
Level
Meter
50
62-MMF
90
62-MMF
50
10
0.2
0.5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
81
High performance
Circuit Diagram
Circuit 1
Applications
Circuit 2
Digital equipment
Switching power supplies
Personal computers and peripherals
Measuring instruments and medical equipment
Telecommunications equipment
Equipment requiring very high noise attenuation
Circuit 3
Specifications
Model
12-MMF-002-5-F
12-MMF-003-5-F
12-MMF-003-5-A
12-MMF-006-5-F
12-MMF-006-5-G
12-MMF-008-5-B
12-MMF-010-5-F
12-MMF-010-5-G
12-MMF-010-5-B
12-MMF-012-5-B
12-MMB-015-5-E
12-MMB-020-5-F
12-MMB-030-5-D
12-MMB-050-5-C
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage
Current (Max.)
2A
3A
120/250VAC
Circuit
Diagram
Figure
A
B
C
6A
8A
10A
0.5mA
B
2
12A
15A
20A
30A
50A
Temperature Rise
(Max.)
30C
D
E
D
F
G
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Leakage current: 0.7 mA max.
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
82
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Figure C
2.12
(54)
1.81 2.44
(46) (62)
1.26 (32)
.87 (22)
2.44 (62)
Figure B
Figure D
.25 (6.4) (2X)
2.00
(51)
2.24
(57)
Figure E
Figure F
M4 THREAD (5X)
M4 STUD (7X)
2.90 (73)
2.42 (87)
4.01 (102)
1.77 (45)
Figure G
.117 (4.5) X .25 (6.3) SLOT (4X)
M4 THREAD
M6 THREAD (4X)
.71 (18)
1.50 (38)
6.30 (160)
7.24 (184)
7.95 (202)
2.30 (58)
1.51 (38.5)
2.01 (51)
3.88 (98.5)
5.31 (135)
1.97 (50)
3.15 (80)
4.72 (120)
7.09 (180)
Common Mode
2.40 .007
(60 .2)
3.38 1.65
(86) (42)
Normal Mode
1
3
Filter
2
4
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
12-MMF-002;-003;-006;-008
50
50
Level
Meter
50
12-MMF-002;-003;-006;-008
80
80
70
70
60
12-MMF-006-5-G
12-MMF-002-5-F
50
12-MMF-003-5-F
40
12-MMF-006-5-F
12-MMF-006-5-G
30
20
12-MMF-008-5-B
60
12-MMF-002-5-F
50
12-MMF-006-5-F
12-MMF-003-5-F
40
12-MMF-008-5-B
30
20
12-MMF-003-5-A
10
10
0
0.01
12-MMF-003-5-A
0.05
0.15 0.45 1
10
20
0
0.01
50
0.05
0.15 0.45 1
Frequency (MHz)
10
20
50
Frequency (MHz)
12-MMF-010;-012;-015;-020;-030;-050
12-MMF-010;-012;015;-020;-030;-050
80
80
70
70
60
12-MMB-030-5-D
50
12-MMB-050-5-C
40
12-MMB-015-5-E
12-MMF-010-5-F
12-MMF-010-5-G 12-MMB-020-5-F
12-MMF-010-5-B
12-MMF-012-5-B
30
20
10
0
0.01
0.05
0.15 0.45 1
Frequency (MHz)
10
20
50
12-MMB-050-5-C
60
50
40
12-MMB-030-5-D
30
12-MMF-010-5-F
12-MMF-010-5-G
12-MMF-010-5-B
12-MMF-012-5-B
12-MMB-015-5-E
12-MMB-020-5-F
20
10
0
0.01
0.05
0.15 0.45 1
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
83
High performance
Circuit Diagram
Circuit 1
Applications
Digital equipment
Personal computers and peripherals
Measuring instruments and medical equipment
Telecommunications equipment
Equipment requiring very high noise attenuation
Circuit 2
Specifications
Model
12-MMF-003-11-F
12-MMF-006-11-F
12-MMF-010-11-F
12-MMB-012-11-A
12-MMB-015-11-G
12-MMB-020-11-D
12-MMB-030-11-D
12-MMB-040-11-B
12-MMB-040-11-E
12-MMB-050-11-H
Rated Voltage
(@ 50/60Hz)
120/250VAC
Rated
Current
3A
6A
10A
12A
15A
20A
30A
Leakage
Current (Max.)
1.5mA
40A
50A
Circuit
Diagram
Figure
B
C
1
2
1
Temperature Rise
(Max.)
30C
B
D
E
F
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Leakage current: 0.7 mA max.
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
Weight: 6.0 ounces (170 grams)
84
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Figure B
Figure D
4.13
MAX
(105)
2.24
(57)
2.01 .02
(51 0.5)
3.90 MAX (99)
6.20 MAX (157)
Figure F
2.28
(58)
1.77 (45)
.95
(24.1)
2.24
(57)
.35 (9)
.90 (23)
8.66 (220)
9.57 (243)
10.27 (261)
3.54
(90)
M8 THREAD (4X)
3.54 5.90
(90) (150)
2.90 (73)
3.42 (87)
4.30 (109)
1.80 (45)
Figure E
M6 THREAD (5X)
M4 THREAD (4X)
1.77
(45)
2.91 (74)
3.66 (93)
4.01 (102)
1.97
(50)
3.14 (80)
4.72 (120)
7.08 (180)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
50
50
Level
Meter
50
12-MMF-003;-006;-010;-012;-015
12-MMF-003;-006;-010;-012;-015
120
120
12-MMF-003-11-F
12-MMF-012-11-A
105
105
12-MMF-003-11-F
12-MMF-012-11-A
90
Figure A
75
60
12-MMF-006-11-F
45
12-MMF-010-11-F
30
15
0
0.1
90
75
60
45
12-MMF-015-11-G
30
12-MMF-006-11-F
12-MMF-015-11-G
15
12-MMF-010-11-F
0
0.2
0.5
10
20
0.1
50
0.2
0.5
10
20
50
Frequency (MHz)
Frequency (MHz)
12-MMF-020;-030;-040;-050
12-MMF-020;-030;-040;-050
120
120
12-MMF-040-11-B
12-MMF-020-11-D
105
105
90
90
12-MMF-040-11-B
75
60
45
30
75
60
45
12-MMF-050-11-H
30
12-MMF-040-11-E
12-MMF-040-11-E
15
0.2
0.5
12-MMF-020-11-D
12-MMF-050-11-H
0
0.1
12-MMF-030-11-D
15
12-MMF-030-11-D
2
Frequency (MHz)
10
0
20
50
0.1
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
85
Circuit Diagram
Circuit 1
Applications
Digital equipment
Personal computers and peripherals
Measuring instruments and medical equipment
Telecommunications equipment
Equipment requiring very high noise attenuation
Circuit 2
Circuit 3
Specifications
Model
12-MMF-001-5-F
12-MMF-003-5-G
12-MMF-003-2-G
12-MMF-006-5-G
12-MMB-010-5-D
12-MMB-015-5-E
12-MMB-020-5-E
12-MMB-030-5-E
Rated Voltage
(@ 50/60Hz)
Rated
Current
1A
3A
120/250VAC
6A
10A
15A
20A
30A
Leakage
Current (Max.)
Circuit
Diagram
0.5mA
5uA
Figure
A
B
C
0.5mA
Temperature Rise
(Max.)
30C
2
D
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Leakage current: 0.7 mA max.
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
Weight: 6.0 ounces (170 grams)
86
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Figure A
2.01
(51)
2.52 (64)
2.95 (75)
3.70 (94)
1.06 (27)
M4 THREAD (5X)
Figure D
.25 (6.4) .37 (9.4) HOLE (4X)
M4 STUD (7X)
3.33
1.73 .03 (84.5)
(44 1)
MAX
3.74 .02
(95 0.5)
4.13 MAX.
(64)
2.36 .007
(60 .2)
3.38 1.65
(86) (42)
2.01 .02
(51 .05)
1.52 (39)
MAX
2.28 (58)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50
7.09 (180)
7.24 (184)
7.95 (202)
.71 (18)
1.50 (38)
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
12-MMF-001;-003;-006
50
12-MMF-001;-003;-006
120
120
12-MMF-006-5-G
12-MMF-006-5-G
105
105
12-MMF-003-2-G
90
12-MMF-003-5-G
75
60
45
30
12-MMF-003-2-G
12-MMF-001-5-F
15
0
0.1
90
75
60
12-MMF-003-5-G
45
30
12-MMF-001-5-F
15
0
0.2
0.5
10
20
0.1
50
0.2
0.5
Frequency (MHz)
10
20
50
Frequency (MHz)
12-MMB-010;-015;-020;-030
12-MMB-010;-015;-020;-030
120
120
12-MMB-010-5-D
12-MMB-015-5-E
105
105
12-MMB-020-5-E
90
50
Level
Meter
50
Figure C
75
60
12-MMB-030-5-E
45
30
12-MMB-010-5-D
12-MMB-015-5-E
12-MMB-020-5-E
90
75
12-MMB-030-5-E
60
45
30
15
15
0
0.1
0.2
0.5
Frequency (MHz)
10
20
50
0.1
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
87
62-PMB/63-PMF Series
Features
L
L
CX
CX
CY
CX
CY
CY
Applications
Circuit Diagram
CX
Digital equipment
Industrial equipment (UPS, inverters
and converters)
Automation equipment
Computerized washing machines
CY
L
CY
CX
CX
CY
CY
CX
CX
CX CX CX
L
CY
CY
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage Current
(Max.)
CY
CX
Inductance
(L1)
Temperature
Rise (Max.)
62-PMB-050-6-12
250VAC
5A
0.6mA
2200pF
0.22uF
115mH
45C
1.0mA
4700pF (4X)
470uF (3X)
3.0mA
0.015uF (2X)
1.0uF (6X)
3A
63-PMF-030-8-14
63-PMF-080-8-14
63-PMF-160-9-21
420VAC
8A
16A
Capacitance
1.0mH (4X)
30C
0.74mH (4X)
40C
1.2mH (4X)
45C
88
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Temperature Characteristics
62-PMB/63-PMF Series
62-PMB-050-6-12 (5 Amp)
5 .157
(M4)
.865 (22)
2.753
(70)
3.460 3.539
(88) (90)
.865 (22)
.039 (1)
1.376
(35)
Fast-on
tab #250
2 - .197
(5) Hole
.629
(16)
.708
(18)
BL
BK
BL
.547
(13.9)
.547
(13.9)
3.585 (91.2)
1.809
(46)
4 - .216
(5.5) Hole
Fast on
tab #250
2.045
(52)
.983
(25)
BK
.208
(5.3)
.350 (8.9)
.362
(9.2)
4.404
(112) .350 (8.9)
.350 (8.9)
4.286
(109)
Fast on
tab #250
(Ground
tab)
3.146
(80.00.5)
5.112 (130.0)
5.702 (145 0.5)
6.292 (160)
Common Mode
Normal Mode
62-PMB-050-6-12 (5 Amp)
62-PMB-050-6-12 (5 Amp)
* General
tolerance
..059 (1.5)
1.494 (38)
2.359 (60)
.708
(18)
63-PMF-160-9-21
63-PMF-160-9-21
63-PMF-080-8-14
63-PMF-030-8-14
63-PMB-050-8-12
63-PMF-030-8-14
63-PMF-080-8-14
63-PMB-050-8-12
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
89
Circuit Diagram
Circuit 1
Applications
Digital equipment
Industrial equipment (UPS, inverters
and converters)
Automation equipment
Computerized washing machines
A'
B'
C'
N
G
N'
Circuit 2
A'
B'
C'
N
G
N'
Specifications
Model
13-PWF-005-12-H
13-PWL-005-12-C
13-PWF-010-12-H
13-PWL-010-12-C
13-PWB-010-12-D
13-PWB-015-12-D
13-PWB-020-12-D
13-PWB-025-12-D
13-PWB-030-12-D
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage
Current (Max.)
Circuit
Diagram
Figure
A
B
A
B
5A
10A
1.5mA
440/250VAC
15A
20A
25A
30A
Temperature Rise
(Max.)
30C
2
90
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Figure B
Figure A
Figure C
2.0 (51)
3.9 (98.5)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
13-PWF-005;-010;-PWL-005;-010;-PWB-010
13-PWB-010-12-D
70
Insertion Loss (dB)
60
50
40
13-PWF-010-12-H
13-PWL-010-12-C
30
13-PWB-010-12-D
20
10
60
50
40
13-PWF-005-12-H
13-PWL-005-12-C
30
20
13-PWF-010-12-H
13-PWL-010-12-C
10
0.2
0.5
10
20
0
0.1
50
0.2
0.5
Frequency (MHz)
13-PWB-015;-020;-025:-030
10
20
50
10
20
50
13-PWB-015;-020;-025:-030
80
70
13-PWB-015-12-D
13-PWB-020-12-D
13-PWB-025-12-D
70
13-PWB-015-12-D
13-PWB-020-12-D
13-PWB-025-12-D
60
50
Frequency (MHz)
80
40
30
13-PWB-030-12-D
20
10
0
0.1
50
Level
Meter
50
80
13-PWF-005-12-H
13-PWL-005-12-C
70
Insertion Loss (dB)
50
13-PWF-005;-010;-PWL-005;-010;-PWB-010
80
0
0.1
5.3 (135)
60
50
40
13-PWB-030-12-D
30
20
10
0.2
0.5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
91
Circuit Diagram
Circuit 1
Applications
Digital equipment
Industrial equipment (UPS, inverters
and converters)
Automation equipment
Switching power supplies
A'
B'
C'
Circuit 2
A'
B'
C'
Specifications
Model
13-PDF-005-11-J
13-PDL-005-11-D
13-PDF-010-11-J
13-PDL-010-11-D
13-PDB-010-11-D
13-PDB-015-11-D
13-PDB-020-11-D
13-PDB-025-11-D
13-PDB-030-11-D
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage
Current (Max.)
Circuit
Diagram
Figure
A
B
A
B
5A
10A
1.5mA
440/250VAC
15A
20A
25A
30A
Temperature Rise
(Max.)
30C
2
92
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Figure B
.177 (4.5) (2X)
2.00
(51)
13-PDF/PDL/PDB Series
2.52 (64)
1.06
(27)
2.95 (75)
3.35 (85)
Figure A
Figure C
.25 (6.3)
M4
THREAD
(10X)
.117 (4.5)
1.42
(36)
2.00
(51)
2.00 (51)
3.88 (98.5)
1.51
(38.5)
3.15 (80)
5.31 (135)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
50
Level
Meter
50
80
13-PDF-005-11-J
13-PDL-005-11-D
70
13-PDB-010-11-D
70
60
50
80
50
40
13-PDB-010-11-D
30
13-PDF-010-11-J
13-PDL-010-11-D
20
10
60
50
13-PDF-010-11-J
13-PDL-010-11-D
40
30
13-PDF-005-11-J
13-PDL-005-11-D
20
10
0
0.1
0.2
0.5
10
20
0
0.1
50
0.2
0.5
Frequency (MHz)
13-PDB-015;-020;-025:-030
10
20
50
10
20
50
13-PDB-015;-020;-025:-030
80
70
70
13-PDB-015-11-D
13-PDB-020-11-D
13-PDB-025-11-D
13-PDB-030-11-D
Insertion Loss (dB)
60
50
40
30
13-PDB-030-11-D
20
10
0
0.1
Frequency (MHz)
80
60
50
40
13-PDB-015-11-D
13-PDB-020-11-D
13-PDB-025-11-D
30
20
10
0.2
0.5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
93
13-PWB Series
Features
Applications
Circuit Diagram
Circuit 1
A
A'
B'
C'
N
G
N'
Circuit 2
A
A'
B'
C'
N
G
N'
Specifications
Model
13-PWB-005-12-A
13-PWB-010-12-B
13-PWB-020-12-B
13-PWB-035-12-C
13-PWB-050-13-C
13-PWB-080-14-D
13-PWB-100-14-D
13-PWB-150-14-E
Rated Voltage
(@ 50/60Hz)
Rated
Current
440/250VAC
5A
10A
20A
35A
50A
80A
100A
150A
Leakage
Current (Max.)
Circuit
Diagram
4.5mA
1
30C
9.0mA
20mA
Temperature Rise
(Max.)
94
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
High Performance
I
L
M E
F D
13-PWB Series
K
B
A
C
G
N
J
Dimensions
9.6
(243)
8.7
(220)
10.3
(261)
13-PWB-080-14-D
13.9
(354)
12.6
(320)
2.4
(60)
1.7
(44)
3.1
(81)
13-PWB-050-13-C
13-PWB-100-14-D
3.9
(99)
15.1
(384)
13-PWB-150-14-E
3.8
(96)
4.9
(125)
6.1
(155)
7.3
(185)
3.5
(90)
M6
M4
2.9
(74)
1.9
(49)
M6
2.2
(56)
M8
1.8
(45)
M8
2.3
(58)
M4
1.2
(30)
3.4
(86)
2.4
(62)
2.4 (61)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
50
50
Level
Meter
50
13-PWB-005;-010;-020;-035
13-PWB-005;-010;-020;-035
120
120
13-PWB-010-12-A
105
13-PWB-005-12-A
105
13-PWB-010-12-A
13-PWB-020-12-A
90
1.5 (38)
M4
.98
(25)
Model
75
13-PWB-020-12-A
60
13-PWB-035-12-A
45
30
90
75
60
13-PWB-035-12-A
45
30
13-PWB-005-12-A
15
15
0
0.1
0
0.2
0.5
10
20
0.1
50
0.2
0.5
10
20
50
Frequency (MHz)
Frequency (MHz)
13-PWB-050;-080;-100;-150
13-PWB-050;-080;-100;-150
120
120
13-PWB-080-14-D
13-PWB-100-14-D
13-PWB-080-14-D
105
105
90
75
60
13-PWB-150-14-E
13-PWB-050-13-C
45
30
15
13-PWB-100-14-D
90
75
13-PWB-050-13-C
60
45
13-PWB-150-14-E
30
15
0
0.1
0.2
0.5
Frequency (MHz)
10
20
50
0.1
0.2
0.5
10
20
50
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
95
13-PDB Series
Features
Applications
Digital equipment
Industrial equipment (UPS, inverters
and converters)
Circuit Diagram
Circuit 1
A
A'
B'
C'
Circuit 2
A
A'
B'
C'
Specifications
Model
13-PDB-005-12-A
13-PDB-010-12-A
13-PDB-020-12-B
13-PDB-035-12-B
13-PDB-050-13-B
13-PDB-080-13-C
13-PDB-100-14-C
13-PDB-150-14-C
13-PDB-200-14-D
Rated Voltage
(@ 50/60Hz)
Rated
Current
440/250VAC
5A
10A
20A
35A
50A
80A
100A
150A
200A
Leakage
Current (Max.)
Circuit
Diagram
Temperature Rise
(Max.)
4.5mA
1
30C
9.0mA
20mA
96
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
I
L
H
F D
M E
13-PDB Series
B
A
C
G
N
J
Dimensions
Model
13-PDB-005-12-A
7.2
(184)
6.3
(160)
7.9
(202)
1.6
(42)
2.4
(60)
3.3
(86)
.70
(18)
2.3
(58)
M4
1.5
(38)
M4
9.6
(243)
8.7
(220)
10.3
(261)
2.3
(58)
2.7
(70)
3.9
(100)
.98
(25)
M6
2.3
(58)
1.9
(49)
M6
13-PDB-020-12-B
13-PDB-035-12-B
13-PDB-050-13-B
13-PDB-100-14-C
13.9
(354)
13-PDB-150-14-C
12.6
(320)
15.1
(384)
6.1
(155)
2.5
(66)
13-PDB-200-14-D
7.3
(185)
3.5
(90)
13-PDB-080-13-C
2.9
(74)
M4
1.2
(30)
M8
3.3
(86)
2.4
(62)
2.2
(56)
M8
Common Mode
2.4 (61)
13-PDB-010-12-A
Normal Mode
1
3
Filter
2
4
Oscillator
50
1
3
Filter
2
4
50
Level
Meter
50
Oscillator
50
13-PDB-005;-010;-020;-035
50
50
Level
Meter
50
13-PDB-005;-010;-020;-035
120
120
13-PDB-010-12-A
105
13-PDB-020-12-B
13-PDB-005-12-A
90
105
75
60
13-PDB-035-12-B
45
13-PDB-005-12-A
30
15
0
0
0.02
.1
10
75
60
45
13-PDB-035-12-B
30
13-PDB-020-12-B
15
13-PDB-010-12-A
0.01
90
20
30
0
0
60
0.01
0.02
.1
Frequency (MHz)
13-PDB-050;-080;-100;-150;-200
10
30
60
120
105
105
90
13-PDB-080-13-C
75
60
45
13-PDB-150-14-C
30
13-PDB-100-14-C
13-PDB-050-13-B
13-PDB-100-14-C
13-PDB-050-13-B
90
13-PDB-200-14-D
75
60
45
13-PDB-080-13-C
30
13-PDB-150-14-C
13-PDB-200-14-D
15
0
0
20
13-PDB-050;-080;-100;-150;-200
120
Frequency (MHz)
15
0.01
0.02
.1
10
Frequency (MHz)
20
30
60
0
0
0.01
0.02
.1
10
20
30
60
Frequency (MHz)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
97
Military/Aerospace
Multisection Filters
Features
Applications
Military
Commercial &
military/aerospace
Secured communications
Switching power supplies
Data processing equipment
Ruggedized computers
Radar
Electronic warfare
Ground/air weapon systems
Satellites
Test Specifications
Test
Group
Order
of
Test
Examination
or Test
Test Method
(Per MIL-STD-202)
Post Test
Requirements
Voltage Drop
Leakage Current
UL 1283
Temperature Rise
25C max.
Terminal Strength
Thermal Shock
Humidity
Life
IIA
IIB
III
98
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Military/Aerospace
Multisection Filters
Insertion Loss
52-600-001
Insertion Loss (dB)
80
differential
mode
60
Circuit Schematic
40
common mode
20
0
0.01
0.1
1
10
Frequency (MHz)
100
1000
100
1000
LINE
LOAD
52-600-002
60
common mode
40
differential mode
20
0
0.01
0.1
1
10
Frequency (MHz)
80
Dimensions
1.250
(31.75)
SWITCH
52-600-001
52-600-002
.215
(5.46)
FUSE
CONNECTOR
.250
(6.35)
2.500
(63.50)
.625
(15.8)
1.68
(42.67)
2.98
(75.70)
Model
Temperature
Rating
DCR.
max.
(ohms)
Leakage
Current
(max.)
Mode
(max.)
52-600-001
5A
120/240VAC
-40C to +65C
.20
1 mA
60 Hz
120/240VAC
60 Hz
2.120 .010
(53.85)
3.88
(98.55)
Voltage
Rating
10A
.03 R.
4 PL
2.500
(63.50)
CHASSIS
MOUNTING
HOLE
#6-32 THREADED
INSERTS (4 PL.)
(3.50-32)
Current
Rating
52-600-002
1.250
(31.75)
-40C to +65C
.10
1 mA
10M 100M 1G
COMM
33
65
80
80
80
80
60
DIFF
37
65
80
80
80
COMM
50
70
80
80
70
60
DIFF
25
50
75
80
80
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
99
HIGH PERFORMANCE
Military/Aerospace
Power Line Filters for C.O.T.S./
Multisection
Filters
TEMPEST Applications
# 52-600-001
52-600-002
Circuit Schematic
Insertion Loss
52-523-002
52-523-002
LINE
80
LOAD
60
40
20
0
0.01
0.1
1
10
Frequency (MHz)
100
1000
Dimensions
Military/Aerospace Multisection Filters
52-523-002
.750
(19.05)
.600
(15.24)
2.010
(51.05)
.250
(6.35)
.250
(6.35)
3.000
(76.2)
.375
(9.52)
FUSEHOLDER
1.75
.875 (44.4)
(22.2)
3.50
.875 (88.9)
(22.2)
PLUG
#6-32 THDED
INSERT 4 PLCS.
(3.50-32)
4.00
(101.6)
.625
(15.8)
1.25
(31.75)
Model
Current
Rating
Voltage
Rating
Temperature
Rating
DCR
max.
(ohms)
Leakage
Current
(max.)
Mode
(max.)
52-523-002
5A
120/240VAC
-40C to +65C
.25
1 mA
COMM
55
60
80
80
70
60
DIFF
50
60
80
80
60 Hz
10M 100M 1G
100
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Military/Aerospace
Multisection Filters
Insertion Loss
1212-0502
Insertion Loss (dB)
80
Circuit Schematic
60
1212-0502
40
20
0
0.01
0.1
1
10
Frequency (MHz)
100
1000
Dimensions
.219 TYP.
(5.56)
.656
(16.41)
.418
(10.62)
1.000
(25.4)
.500
(12.7)
.209
(5.31)
.120 TYP.
(3.05)
.594
.031
(.78)
1.187 .015
(30.15 .38)
1.125
(28.58)
MOUNTING
SURFACE
.032
(.81)
.125 6-PLCS.
(3.18 .00)
.875
(22.23)
1.250
(31.75)
.105 TYP.
(2.67)
.281 .031
(7.14 .78)
.710
(18.03)
.187
(4.75)
1.437 .031
(36.50 .78)
Model
Current
Rating
1212-0502
10A
Voltage
Rating
350VDC
Temperature
Rating
-55C to +125C
DCR
max.
(ohms)
Leakage
Current
(max.)
Cx
Value
.01
1 mA
5000pF
.055 TYP.
(1.40)
1212-0502
100M
500M
1G
20
65
70
70
240VAC 60 Hz
Consult factory for UL/CSA approval availability.
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
101
Military/Aerospace
Multisection Filters
Secure Communications
Spectrum's electromagnetic compatibility expertise in
the secure communication or TEMPEST arena is represented by this group of high performance filters. These
units are especially well suited for use in MIL-STD-461
applications to reduce conducted emissions. The filters
are manufactured with glass sealed terminals
and connectors.
Filter Schematic A
LINE
Features
Filter Schematic B
LINE
LOAD
Dimensions
2.50
(63.50)
1.25
(31.75)
Insertion Loss
1.75
(44.45)
52-378-002
LOAD
1.500
(38.10)
.750
2.50
(19.05)
(63.50)
#8-32 UNC THD. INSERTS
(4.17-32)
.350 DEEP, 2 PLACES
(8.89)
CONNECTOR #8001-14S-7P-A3
MATES WITH MS-3106-14S-7S
60
40
20
0
0.01
0.1
1
10
Frequency (MHz)
100
1000
102
Model
Current
Rating
Voltage
Rating
Temperature
Range
DCR
max.
(ohms)
Leakage
Current
(max.)
Schematic
52-378-001
3 Amps
240VAC 60 Hz
Line to Line
-55C to 85C
.3
50 mA
30
60
70
80
80
70
70
52-378-002
5 Amps
240VAC 60 Hz
Line to Line
-55C to 85C
.2
50 mA
24
64
70
80
80
70
70
52-378-004
5 Amps
240VAC 60 Hz
Line to Line
-55C to 85C
.2
50 mA
34
64
70
80
80
70
70
52-378-005
3 Amps
240VAC 60 Hz
Line to Line
-55C to 85C
.3
50 mA
40
70
80
80
80
70
60
50 150 300
1
10 100
1
KHz KHz KHz MHz MHZ MHZ GHz
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Power
Line Filters
Military/Aerospace
Multisection
Filters
for Secure Communications
Filter Schematic C
Insertion Loss
LINE
LOAD
60
52-387-010,
-003 MIL-STD-220
40
Filter Schematic D
52-409-001
MIL-STD-220
20
0
0.01
0.1
1
10
Frequency (MHz)
LINE
100
LOAD
1000
80
Filter Schematic E
LINE
LOAD
Dimensions
Figure 1
2.50
(63.50)
1.25
(31.75)
Figure 2
3.00
(76.20)
2.50
(63.50)
1.25
(31.75)
.625
(15.87)
#8-32 UNC
(4.17-32)
STUD
1.25
(31.75)
1.500
(38.10)
.750
2.50
(19.05)
(63.50)
1.500
(38.10)
.750
2.50
(19.05)
(63.50)
Current
Rating
CONNECTOR #8001-10SL-3PN-FP-A3
MATES WITH MS-3106-10SL-3S
Voltage
Rating
Model
Fig.
52-387-010
10 Amps 240VAC 60 Hz
Line to Line
52-387-012
5 Amps
52-409-001
Temperature
Range
DCR Leakage
max. Current
(ohms) (max.)
common
24
60
70
80
80
70
70
common
34
64
70
80
80
70
70
differential
30
30
70
80
80
common
14
30
45
80
80
70
60
240VAC 400 Hz
-55C to 85C
Line to Line
.2
5 mA
50 mA
Mode
50 mA
.04
Sch.
.2
-55C to 85C
CONNECTOR #8001-14S-7P-A3
MATES WITH MS-3106-14S-7S
-55C to 85C
14 Amps 240VAC 60 Hz
Line to Line
1.75
(44.45)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
103
Military/Aerospace
Multisection Filters
Secure Communications
Features
06
Q
Model
Current Rating:
3, 6, 10, 15 Amps
Electrical Specifications
Rated current ranges ..................
Rated voltage.............................
Operating frequency...................
Maximum leakage current
@115VAC 60 Hz............
@250VAC 50 Hz............
Test voltage
Line-to-Line ....................
Line-to-Ground...............
3, 6, 10, 15 Amps
115-250VAC
50-60 Hz
Terminal Style:
A=.25 Quick Connect
C=Wire Leads (4" min.)
1.2 mA
2.5 mA
1450VDC
2250VDC
Insertion Loss
760, 761, 762 - 3, 6 Amps
common mode
80
Insertion Loss (dB)
80
60
40
20
differential mode
0
0.01
0.1
1
10
Frequency (MHz)
100
1000
common mode
60
40
20
differential mode
0
0.01
0.1
1
10
Frequency (MHz)
100
1000
Common Mode (CM) is tested in a 50 ohm system with all lines tied together on the line and load sides of the filter.
Differential Mode (DM) is tested in a 50 ohm system using a 180 phase splitter on both sides of the filter.
104
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Military/Aerospace
Multisection Filters
Dimensions - 760 Series
.55 (13.97)
Current
Rating
(Amps)
Series
3, 6
2.25
(57.15)
3.00
(76.20)
1.88
(47.75)
10, 15
5.50
(139.70)
3.15
(88.01)
2.10
(53.34)
A
760
1.23
(31.24)
Filter Dimensions
A
.13 (3.30)
B
1.332
(33.83)
.67 (42.41)
.66 (16.67)
TERMINATION
STYLE A
TERMINATION
STYLE C
Dimensions in inches (mm)
Series
Current
Rating
(Amps)
761, 762
Filter Dimensions
A
3, 6
2.55
(64.77)
2.97
(75.43)
1.88
(47.75)
761
10, 15
5.50
(139.70)
3.15
(88.01)
2.10
(53.34)
762
10, 15
5.75
(146.05)
3.15
(88.01)
2.10
(53.34)
1.312
(33.32)
.95 (24.13)
3.00
(76.2)
0.20
(5.08)
1.30
(33.02)
1.30
(33.02)
0.20 (5.08)
0.80
(20.32)
1.875
(47.62)
6-32 UNC-2B
(6 Places)
B
3.67
(93.21)
0.80
(20.32)
.40 (10.16)
Switch Omitted
in Model 761
3, 6, 10, AMP
FRONT PANEL
Switch Omitted
in Model 761
15 AMP
FRONT PANEL
.55 (13.97)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
105
Custom/Application
Specific Filters
SpectrumControl will address virtually any requirement for
a custom power product. Our many years of experience in
providing EMI/RFI solutions has allowed us to satisfy both
global EMC regulations and time-to-market constraints.
Spectrum Controls engineering expertise and vertical
integration reduces your speed-to-market, as well as
saves you money.
Features/Benefits
Options
EMI filtering
Transient protection
Circuit breaker protection
Voltage cut-off
Reverse polarity
Power distribution
Indicator lights
Leads or studs
Agency approvals
Performance Characteristics
Insertion loss range
up to 500 Amps
-25 C to +85 C
106
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
EMI Filtering
Custom/Application
Specific Filters
Circuit
Breaker
Protection
Power
Distribution
Multiple
Outlets
Power Distribution
Power Entry
EMI Filtering
Transient Protection
-48 VDC
-60 VDC
Rugged
Construction
Pigtail Leads
UL Recognized
Complies to UL 1459
CSA Certified
High Current
Terminal Block
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
107
Custom/Application
Specific Filters
Spectrum Control's design teams can help transform
a functional electronic design into an easy to install
EMI filtered package containing all required components.
We will define your EMC problem through our test
facilities, develop a filter solution and manufacture
product to meet your schedule.
108
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Custom/Application
Specific Filters
Filtered
Terminal Blocks
Power
Line Filters
109
Appendix
110
10-BPF-XXX-2-X . . . . . . . . . . . . . .32
10-BPF-XXX-5-X . . . . . . . . . . . . . .30
10-BPL-XXX-5-X . . . . . . . . . . . . . .38
11-MPC-XXX-X-X . . . . . . . . . . . . .58
12-MMB-XXX-5-X . . . . . . . . . . . . .82
12-MMB-XXX-5-X . . . . . . . . . . . . .86
12-MMB-XXX-11-X . . . . . . . . . . . .84
12-MMF-XXX-5-X . . . . . . . . . . . . .82
12-MMF-XXX-5-X . . . . . . . . . . . . .86
12-MMF-XXX-11-X . . . . . . . . . . . .84
12-PMB-XXX-DC-X . . . . . . . . . . . .78
12-PMB-XXX-X-X . . . . . . . . . . . . .76
12-PMF-XXX-DC-X . . . . . . . . . . . .78
12-PMF-XXX-2-X . . . . . . . . . . . . .66
12-PMF-XXX-5-X . . . . . . . . . . . . .72
12-PML-XXX-X-X . . . . . . . . . . . . .66
13-PDB-XXX-XX-X . . . . . . . . . . . .92
13-PDB-XXX-XX-X . . . . . . . . . . . .96
13-PDF-XXX-XX-X . . . . . . . . . . . .92
13-PDL-XXX-XX-X . . . . . . . . . . . .92
13-PWB-XXX-XX-A . . . . . . . . . . . .94
13-PWB-XXX-XX-B . . . . . . . . . . . .94
13-PWB-XXX-XX-C . . . . . . . . . . . .94
13-PWB-XXX-14-D . . . . . . . . . . . .94
13-PWB-XXX-XX-E . . . . . . . . . . . .94
13-PWB-010-12-D . . . . . . . . . . . . .90
13-PWB-015-12-D . . . . . . . . . . . . .90
13-PWB-020-12-D . . . . . . . . . . . . .90
13-PWB-025-12-D . . . . . . . . . . . . .90
13-PWB-030-12-D . . . . . . . . . . . . .90
13-PWF-XXX-XX-X . . . . . . . . . . . .90
13-PWL-XXX-XX-X . . . . . . . . . . . .90
52-226-001 . . . . . . . . . . . . . . . . . .20
52-226-002 . . . . . . . . . . . . . . . . . .20
52-226-004 . . . . . . . . . . . . . . . . . .20
52-226-006 . . . . . . . . . . . . . . . . . .20
52-226-008 . . . . . . . . . . . . . . . . . .20
52-226-009 . . . . . . . . . . . . . . . . . .20
52-226-011-XX . . . . . . . . . . . . . . .12
52-226-015 . . . . . . . . . . . . . . . . . .20
52-226-016-XX . . . . . . . . . . . . . . .16
52-226-019-XX . . . . . . . . . . . . . . .18
52-226-020-XX . . . . . . . . . . . . . . .14
52-226-021-XX . . . . . . . . . . . . . . .12
52-226-026-XX . . . . . . . . . . . . . . .16
52-226-029-XX . . . . . . . . . . . . . . .14
52-226-031-XX . . . . . . . . . . . . . . .12
52-226-036-XX . . . . . . . . . . . . . . .16
52-226-037-XX . . . . . . . . . . . . . . .18
52-226-041-XX . . . . . . . . . . . . . . .12
52-226-046-XX . . . . . . . . . . . . . . .16
52-267-002 . . . . . . . . . . . . . . . . . .20
52-267-003 . . . . . . . . . . . . . . . . . .20
52-267-008 . . . . . . . . . . . . . . . . . .20
52-267-009 . . . . . . . . . . . . . . . . . .20
52-267-010 . . . . . . . . . . . . . . . . . .20
52-267-011 . . . . . . . . . . . . . . . . . .20
52-267-012 . . . . . . . . . . . . . . . . . .20
52-378-XXX . . . . . . . . . . . . . . . .102
52-387-XXX . . . . . . . . . . . . . . . .103
52-409-XXX . . . . . . . . . . . . . . . .103
52-523-002 . . . . . . . . . . . . . . . . .100
52-600-XXX . . . . . . . . . . . . . . . . .99
52-1013-XXX . . . . . . . . . . . . . . . .23
60-BHP-XXX-X-X . . . . . . . . . . . . .56
60-BHS-XXX-X-X . . . . . . . . . . . . .28
60-BPF-XXX-X-X . . . . . . . . . . . . .26
60-BPL-XXX-X-X . . . . . . . . . . . . . .36
60-BPP-XXX-X-X . . . . . . . . . . . . .54
60-BPR-XXX-X-X . . . . . . . . . . . . .24
60-BPS-XXX-X-X . . . . . . . . . . . . .24
60-SPL-XXX-X-X . . . . . . . . . . . . . .34
60-SPR-XXX-X-X . . . . . . . . . . . . .40
60-SPS-XXX-X-X . . . . . . . . . . . . .40
61-MPC-XXX-X-XX . . . . . . . . . . . .52
62-AFC-XXX-X-XX . . . . . . . . . . . .60
62-AFL-XXX-X-XX . . . . . . . . . . . . .60
62-LMF-XXX-X-XX . . . . . . . . . . . .68
62-LMB-XXX-X-XX . . . . . . . . . . . .68
62-MMF-XXX-X-XX . . . . . . . . . . . .80
62-PMB-XXX-5-XX . . . . . . . . . . . .70
62-PMB-XXX-6-XX . . . . . . . . . . . .88
62-PMB-XXX-X-XX . . . . . . . . . . . .74
62-PMF-XXX-5-XX . . . . . . . . . . . .70
62-PML-XXX-X-XX . . . . . . . . . . . .64
62-PPF-XXX-X-XX . . . . . . . . . . . .62
62-PQF-XXX-X-XX . . . . . . . . . . . .62
62-PRF-XXX-X-XX . . . . . . . . . . . .62
63-PMF-XXX-8-XX . . . . . . . . . . . .88
63-PMF-XXX-9-XX . . . . . . . . . . . .88
64-BFF-XXX-X-X . . . . . . . . . . . . . .42
64-BFS-XXX-X-X . . . . . . . . . . . . .42
64-BSF-XXX-X-XX . . . . . . . . . . . .46
64-SSF-XXX-X-XX . . . . . . . . . . . .46
65-BFF-XXX-X-X . . . . . . . . . . . . . .42
65-BFS-XXX-X-X . . . . . . . . . . . . .42
65-BSF-XXX-X-XX . . . . . . . . . . . .46
65-SSF-XXX-X-XX . . . . . . . . . . . .46
66-BFF-XXX-X-X . . . . . . . . . . . . . .44
66-BFS-XXX-X-X . . . . . . . . . . . . .44
66-BFS-XXX-X-X . . . . . . . . . . . . .44
66-BSF-XXX-X-XX . . . . . . . . . . . .48
66-SSF-XXX-X-XX . . . . . . . . . . . .48
67-BFF-XXX-X-X . . . . . . . . . . . . . .44
67-BFS-XXX-XX . . . . . . . . . . . . . .44
67-BSF-XXX-X-X . . . . . . . . . . . . .48
67-SSF-XXX-X-X . . . . . . . . . . . . .48
68-BSF-XXX-X-XX . . . . . . . . . . . .50
760-XXXX . . . . . . . . . . . . . . . . . .106
761-XXXX . . . . . . . . . . . . . . . . . .106
762-XXXX . . . . . . . . . . . . . . . . . .106
1212-0502 . . . . . . . . . . . . . . . . . .101
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Appendix
Notes
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
111
Appendix
Notes
112
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Outlet/Inlet Type:
Duplex
Single
IEC
Vendor
P/N
Company name
Other
Name/Title
AC
Requirements:
Address
City
Phone (
State
)
Fax (
120VAC
Other
Zip
)
Frequency
(Hz):
Target price
Anticipated yearly usage
Current
(Amps):
Life of program
250VAC
50
400
60
Other
Three
Quotation
Delta (3 wires)
Prototype
Wye (4 wires)
First Article
Other
Production Start Up
Leakage
Current:
Product Offering Suggested for this Application:
(Check appropriate response)
DC
Requirements:
mA (max.)
Voltage:
Current (Amps):
Insertion Loss
Requirements:
Accessories
Physical Parameters
Mechanical Requirements:
Surge
Suppression:
Maximum Dimensions:
Height (inches)
Length (inches)
No
Yes
Define
Width
Please include drawing or sketch, if available.
Circuit
Breaker:
Electrical Parameters
No
Current Rating
LOAD SIDE
Vendor
P/N
Lighted
Non-lighted
Remote
None
UL
CE
CSA
TUV
Connector
Studs
Switches:
Pigtails/leads
Connector
Terminal
Block
Agency
Approvals:
Appendix
Voltage Rating
Electrical Terminations:
LINE SIDE
Yes
Other
Other
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
113
Control Products
Systems Company
&
Global
Manufacturing
EMI Filters
and Filtered
Power
Products
Frequency
Control
Products
Power
Management
Systems
CERTIFIED
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
115
Control Products
Systems Company
&
Corporate Headquarters
8031 Avonia Road
Fairview, Pennsylvania 16415
Phone: 814-474-2207
Fax:
814-474-2208 NEW
Sales Offices
NORTH AMERICA
NEW
6798 Oak Hall Lane
Columbia, Maryland 21045
Phone: 301-916-2919
Fax:
301-916-2910
EUROPE
Spectrum Control GmbH
Hansastrasse 6
91126 Schwabach, Germany
Phone: (49)-9122-795-0
Fax:
(49)-9122-795-58
AHA
12/03
20M
27-0027-0046
CHINA
Spectrum Control Limited
Room 73-78 - 2nd Floor
Sino Industrial Plaza
NEW
9 Kai Cheung Road
Kowloon Bay
Kowloon, Hong Kong
Phone: (011)-852-2197-9912
Fax:
(011)-852-2750-9663
For additional information regarding
Spectrum Control, our full line of
EMI filtering and power products
and our many new products,
call us or contact our Website at
http://www.spectrumcontrol.com
Spectrum Control, Inc. reserves
the right to alter the specifications
provided in this publication.
Consult factory for current
specifications.
CERTIFIED
Printed in U.S.A.
Mouser Electronics
Authorized Distributor
API Technologies: