General Wall Mounted

Saudi Arabia
SV Chassis
R22 / 60Hz
KR-6RMG2-01A

General Wall Mounted


R22/60Hz
1. Models line up
2. Nomenclature
3. Features & Benefits
4. Specifications
5. Dimensions
6. Wiring diagrams
7. Refrigerant cycle Diagrams
8. Capacity tables
9. Capacity coefficient factor
10. Airflow and Temperature Distribution
11. Remote controller
12. Installation

General Wall Mounted


Test condition of international standard
ISO
5151

ARI
210/240

AHAM

AS
1861.1

SSA
385

Indoor

DBC(F)

27.0

27.0

26.7(80)

26.7(80)

27.0

29.0

Cooling

WBC(F)

19.5

19.0

19.4(67)

19.4(67)

19.0

19.0

Capacity

Outdoor

DBC(F)

35.0

35.0

35.0(95)

35.0(95)

35.0

46.0

WBC(F)

24.0

24.0

23.9(75)

23.9(75)

24.0

24.0

Indoor

DBC(F)

20.0

20.0

21.1(70)

21.1(70)

20.0

21.0

Heating

WBC(F)

15.0

15.0

15.6(60)

15.6(60)

15.0

15.5

Capacity

Maximum

Outdoor

DBC(F)

7.0

7.0

8.3(47)

8.3(47)

7.0

7.0

WBC(F))

6.0

6.0

6.1(43)

6.1(43)

6.0

6.0

Indoor

DBC(F)

32.0

32.0

26.7(80)

32.2(90)

32.0

29.0

Cooling

WBC(F)

23.0

23.0

19.4(67)

22.8(73)

23.0

19.0

Operating

Outdoor

DBC(F)

43.0

43.0

46.1(115)

43.3(110)

43.0

54.0

WBC(F)

26.0

26.0

23.9(75)

25.6(78)

26.0

24.0

Maximum

Indoor

DBC(F)

27.0

27.0

26.7(80)

26.7(80)

Heating

WBC(F)

19.0

19.0

19.4(67)

22.8(73)

Operating
Enclosure

Outdoor

DBC(F)

21.0

24.0

23.9(75)

23.9(75)

WBC(F)

15.0

18.0

18.3(65)

18.3(65)

Indoor

DBC(F)

27.0

27.0

26.7(80)

26.7(80)

27.0

27.0

Sweat /

WBC(F)

24.0

24.0

23.9(75)

23.9(75)

24.0

24.0

Condensate

Outdoor

DBC(F)

27.0

27.0

26.7(80)

26.7(80)

27.0

27.0

Disposal

WBC(F)

24.0

24.0

23.9(75)

23.9(75)

24.0

24.0

Freeze-up/

Indoor

DBC(F)

21.0

21.0

19.4(67)

21.1(70)

21.0

21.0

Low

WBC(F)

15.0

15.0

13.9(57)

15.6(60)

16.0

16.0

Temperature Outdoor

DBC(F)

21.0

21.0

19.4(67)

21.1(70)

21.0

21.0

WBC(F)

15.0

15.0

13.9(57)

15.6(60)

16.0

16.0

KS : Korea Standard
ISO : International Standard Organization
ARI : Airconditioning and Refrigeration Institute
AHAM : Association of Home Appliance Manufacturers

AS : Australia Standard
SSA : Saudi Arabian Standard

General Wall Mounted

KSC
9306

CLASSIFICATION

General Wall Mounted

General Wall Mounted


General Description
Split system type air conditioners are known by the category name of Wall Mounted Type systems. The indoor and
outdoor unit can be easily installed in a small space and have exceptional cooling capacity. Designed for low noise
operation, these systems ensure a pleasant air conditioned environment.
LG offers various types of units to its customers to satisfy various applications and requirements. The following are the
important categories offered by LG :
1) General Wall Mounted Type Units : Units with Simplicity in design.
2) Art Cool Units : A new concept of cooling introduced by LG in the field of Air Conditioning.
3) Inverter Units : These units are capable of minimising the Power consumption with the unique inverter technology.
Some of the Important Features of these units are listed below :
1) Providing Health to the Customers : By having the Filters such as Plasma Filter which is capable of removing the
Micro Organisms up to 0.1 microns.
2) Long Term Money Saving : By providing Features such as Gold Fin, Auto Clean etc. to maintain the same
performance for the years.
3) Best Comfort : With Features such as Sleep Mode,Timer,Auto Restart etc.
The units are available with many standard and optional features which give our customers the choice to select the unit
of their own desire. For more information refer to the detailed specification following this description.

LG Electronics Inc.
Air Conditioning & Energy Solution Company

General Wall Mounted


Publication history
Product Name

Notes

Publication in

KR-6RMG2-01A

SRAC

12 Models

Apr. 2013

General Wall Mounted

PDB No.

General Wall Mounted


1. Models Line up
General Wall Mounted

Edition

Type

Capacity

Factory Model

Buyer Model

30K

LS-C302V4A0

S3024C

LS-C322V4B0

S3224C

LS-C322V8C0

S3228P

LS-C362V4A0

S3624C

LS-C382V4B0

S3824C

LS-C382V8C0

S3828P

LS-H302V4A0

S3024H

LS-H322V4B0

S3224H

LS-H322V8C0

S3228Q

LS-H362V4A0

S3624H

LS-H382V4B0

S3824H

LS-H382V8C0

S3828Q

32K
C/O
36K

38K
#01A
30K

32K
H/P
36K

38K

General Wall Mounted


2. Nomenclature
L

General Wall Mounted

Serial Number
Function
A: Non Plasma + 2way
B: Non Plasma + 4way
C: Charger HAF + 4way + All in one HAF
Look/Color
Chassis Look
4
V (SV)
8

Classification
White
Libero(White+Silver spray deco)

Electric Rating
2: 220V, 60Hz
Capacity
EX) '38' 38,000 Btu/h Class
'36' 36,000 Btu/h Class
'32' 32,000 Btu/h Class
'30' 30,000 Btu/h Class
Model Type
H: Heat Pump
C: Cooling only
Supply Method Diving and Type
-: SET
Product Type
S: Split
Refrigerant Type
L: R22

General Wall Mounted


3. Features & Benefits
General Wall Mounted

3.1 Unique Features


-`\ZMUM,]ZIJQTQ\a
<PMKWUJQVI\QWVWN\ZWXQKITKWUXZM[[WZIVL\PM
QUXZW^MLL]ZIJQTQ\aWN4/IQZKWVLQ\QWVMZ

<ZWXQKIT+WUXZM[[WZ

8W_MZ+WWTQVO
LQ[\IVKMWNU\WITTKWZVMZ[WN\PM
ZWWUSMMXQVO\PM[XIKMKWWTIVL
KWUNWZ\IJTMZMOIZLTM[[WNW]\[QLM
\MUXMZI\]ZM

<ZWXQKIT+WUXZM[[WZ" <PMIL^IVKML\ZWXQKIT
KWUXZM[[WZQ[J]QT\\W_Q\P[\IVLM`\ZMUM_MI\PMZ
KWVLQ\QWV[ITTW_QVOQ\\WWXMZI\MLM[XQ\MPQOP
\MUXMZI\]ZM[W]\[QLM

/WTL.QV"
M`\MZQWZ]VQ\PMTXXZW\MK\\PMPMI\M`KPIVOMZNZWU
KWZZW[QWVIVL_MIZL]M\W[IT\[IVLIVLW\PMZ
MTMUMV\[

*QO)QZ>WT]UM

*QO)QZ>WT]UM"4/[]VQY]M;SM_NIVOMVMZI\M[I
OZMI\MZ^WT]UMWNIQZIVLZMIKPM[\WUNIZ
\WUISM\PMZWWUU]KPKWWTMZU]KPNI[\MZ

_Ia[_QVOLQ[XMZ[M[KWWTIQZ
Y]QKSTaIVLMNNMK\Q^MTaQVU]T\QXTMLQZMK\QWV[\WMIKP
KWZVMZWN\PMZWWU

8MZNMK\0MIT\P+IZM
WLWZ[WZPIZUN]T[]J[\IVKM[[]KPI[^QZ][M[
JIK\MZQIIVLITTMZOMV[



;UWSM)_Ia

1WV,QNN][MZ"UQTTQWVVMOI\Q^MQWV[[XZMILNZWU1WV
,QNN][MZI\\IKP\W\PMUQKZW[KWXQKXIZ\QKTM[
<M[\:M[]T\[
+),:"
;QbMWN)ZMI"U

5QKZW8ZW\MK\QWV.QT\MZ"
TW_VWQ[MKWTTMK\[PIZUN]TUQKZW[KWXQK[]J[\IVKM[_Q\P

,]IT8ZW\MK\QWV.QT\MZ" <PM,]IT8ZW\MK\QWV.QT\MZ
QVQ\QITTaKIX\]ZM[L][\QV\PMIQZ\PI\KWUM[QV\W\PMIQZ
^IZQW][W\PMZ[W]ZKM[

55]T\Q8ZW\MK\QWV.QT\MZ" ,M[QOVML\WKIX\]ZML][\
^QZ][M[IVLITTMZOMV[IVL\PMVLMIK\Q^I\M\PMU\PZW]OP
\PM]VQY]M\MKPVWTWOQM[WN4/IVL5

+aKTW\ZWV

5QKZW.QT\MZ" ?PQTMJMQVO

WN4/IQZKWVLQ\QWVMZ[XZW\MK\[\PM][MZNZWUWLWZ[IVL

General Wall Mounted


3. Features & Benefits



5QKZW
ZW
8ZW\MK\QWV.QT\MZ
QWV.QT\MZ

1WV
,QNN][MZ

/WTL.QV

<ZWXQKIT
+WUXZM[[WZ

!
;\aTQ[P
,M[QOV

General Wall Mounted

<PMI_IZL[IZMOQ^MV\W)Z\KWWTXZWL]K\



;SM_.IV

9]QKS-I[a
1V[\ITTI\QWV

;SM_.IV

,]IT
8ZW\MK\QWV.QT\MZ

>IVM
4W]^MZ

-VMZOa;I^QVO

1V^MZ\MZ>

;\I\MWN\PMIZ\PMI\M`KPIVOMZIQZW]\TM\
KWUXZM[[WZIVLQV^MZ\MZ\MKPVWTWOaIZM
KWUJQVML\WKZMI\M\PM_WZTL[UW[\MVMZOa

-VMZOa;I^QVO"4/[IL^IVKMLQV^MZ\MZ\MKPVWTWOa
TM\[K][\WUMZ[QVKZMI[M][IOM_PQTM[I^QVOUWZM

;\aTQ[P,M[QOV
4/IQZKWVLQ\QWVMZ[IZM[\aTQ[PIVLMTMOIV\\W
XZW^QLMIZMNZM[PQVOILLQ\QWV\WaW]ZPWUM
LMKWZ

<PMLM[QOVWN4/IQZKWVLQ\QWVMZ[IZM[\aTQ[PQV
I_Ia\PI\Q[QVKWUXIZIJTM\WW\PMZ[<PQVSWNQ\
VW\R][\I[IVIQZKWVLQ\QWVMZJ]\IVWJRM\\PI\_QTT
TQOP\MV]XaW]ZTQ^QVOZWWU

9]QKS-I[a1V[\ITTI\QWV
1V[\ITTI\QWVPI[VM^MZJMMVMI[QMZI[_Q\P\PM
LMTQKI\MTaLM[QOVMLQV[\ITTI\QWVMTMUMV\[WN4/
IQZKWVLQ\QWVMZ[



QUXZW^MUMV\,M\IKPIJTMJW\\WUKW^MZ-TM^I\ML
[MZ^QKM^IT^M1V[\ITTI\QWV[]XXWZ\KTQX+WUXI\QJTM_Q\P
\PMQV^MZ\MZU]T\Q[a[\MU

General Wall Mounted


3. Features & Benefits
General Wall Mounted

3.2 Model Line Up


Tropical

< 6+
<6+

=VQY]M.MI\]ZM[

< :+ <:+


< :0<:0

<  8 < 8
<  9 < 9

1V^MZ\MZ>"<PMIL^IVKMLQV^MZ\MZ\MKPVWTWOa
WN4/MVIJTM[\PM][MZWN\PMIQZKWVLQ\QWVMZ\W
][MUWZMIVL[I^MUWZM

-VMZOa
S?

-VMZOa,Q[XTIa")LQ[XTIaWVQVLWWZ]VQ\[PW_[
K]ZZMV\IVLIKK]U]TI\MMVMZOaKWV[]UX\QWV_Q\P
R][\X][PQVOIJ]\\WVWVZMUW\MKWV\ZWTTMZ

4W_6WQ[M"4/[]VQY]MVM_[SM_NIVIVLTW_
^QJZI\QVOKWUXZM[[WZ\MKPVWTWOaPI^MIKPQM^ML
\PMTW_VWQ[MTM^MT

+WUXTM\M
;QTMVKM

,MMX;TMMX5WLM"1VLWWZ]VQ\NIV
KWUXZM[[WZ_QTTWXMZI\M\WUIQV\IQV\PMZWWU
\MUXMZI\]ZMIVLXZW^QLMKWUNWZ\IJTM[TMMX

<ZWXQKIT+WUXZM[[WZ "<PMIL^IVKML\ZWXQKIT
KWUXZM[[WZ_Q\P[\IVL[M`\ZMUM_MI\PMZ
KWVLQ\QWV[MVIJTQVO\PMXZWL]K\\WWXMZI\M
LM[XQ\MPQOPW]\[QLM\MUXMZI\]ZM

,]ZIJQTQ\a

/WTL.QV"
M`\MZQWZ]VQ\\PMPMI\M`KPIVOMZQ[XZW\MK\ML
NZWUKWZZW[QWVIVL_MIZNZWUM`\MZVIT
KWVLQ\QWV[
*QO)QZ>WT]UM"4/[]VQY]M;SM_NIV
OMVMZI\M[IOZMI\MZ^WT]UMWNIQZ\PIV
KWV^MV\QWVIT)+[_Q\P\PM[IUM*<=W]\X]\\W
UISM\PMZWWUU]KPKWWTMZU]KPNI[\MZ
4/IQZKWVLQ\QWVMZLMTQ^MZ[
KWWTIQZ\WM^MZaKWZVMZWNaW]ZZWWU<PM
U]T\QLQZMK\QWV
9]QKS

2M\+WWT "2M\+WWTLQ[XMZ[M[IQZM^MVTaI\PQOP
[XMML\W]V[]ZM\PMZWWUQ[WX\QUITTaKWWTQV
R][\UQV]\M[

-VMZOa,Q[XTIa
4W_6WQ[M
!L*

9]QM\7XMZI\QWV

,MMX;TMMX5WLM
<ZWXQKIT+WUXZM[[WZ+
/WTL.QV
U?QVLJTI[\
_Ia;_QVO;\MX[
2M\+WWT

;UWSM)_Ia
1WV,QNN][MZ"UQTTQWVVMOI\Q^MQWV[[XZMILNZWU
1WV,QNN][MZI\\IKP\W\PMUQKZW[KWXQKXIZ\QKTM[

5QKZW8ZW\MK\QWV.QT\MZ" 55QKZW8ZW\MK\QWV
PIZUN]TUQKZW[KWXQK[]J[\IVKMJa[\ZWVO
,]IT8ZW\MK\QWV.QT\MZ" ,]IT8ZW\MK\QWV.QT\MZ
QVQ\QITTaKIX\]ZM[L][\QV\PMIQZ\PI\KWUM[QV\W
\PMIQZKWVLQ\QWVMZ

8MZNMK\
0MIT\P
+IZM

5QKZW8ZW\MK\QWV.QT\MZ
,]IT8ZW\MK\QWV.QT\MZ

+aKTW\ZWV
5QKZW.QT\MZ"?PQTM
JMQVOMI[a\WUIQV\IQV\PMXW_MZN]TXTI[UINQT\ZI\QWV
[a[\MUWN4/IQZKWVLQ\QWVMZXZW\MK\[\PM][MZNZWU
WLWZIVLIVaPIZUN]T[]J[\IVKM[NTWI\QVOQVIQZ

+aKTW\ZWV

5]T\Q8ZW\MK\QWV.QT\MZ" 55]T\Q
IVLLMIK\Q^I\M[\PMKIX\]ZML^QZ][IVLITTMZOMV
Ja]VQY]M\MKPVWTWOQM[WN4/IVL5
)]\W+TMIVQVO"<PMKWUXZMPMV[Q^M
I]\WKTMIVQVON]VK\QWVXZM^MV\[\PMNWZUQVOWNJIK\MZQI
IVLUWTLWV\PMPMI\M`KPIVOMZ

10

;\aTQ[P
,M[QOV

<PMLM[QOVWN4/IQZ KWVLQ\QWVMZ[IZM[\aTQ[PQV
I_Ia\PI\Q[QVKWUXIZIJTM\WW\PMZ[<PQVSWNQ\
VW\R][\I[IVIQZKWVLQ\QWVMZJ]\IVWJRM\\PI\
_QTTTQOP\MV]XaW]ZTQ^QVOZWWU

1V[\ITTI\QWV
;MZ^QKM

XTI\MQUXZW^MUMV\,M\IKPIJTMJW\\WUKW^MZ
-TM^I\ML[MZ^QKM^IT^M1V[\ITTI\QWV[]XXWZ\KTQX
+WUXI\QJTM_Q\PQV^MZ\MZU]T\Q[a[\MU

5]T\Q8ZW\MK\QWV.QT\MZ
)]\W+TMIVQVO
;\aTQ[P,M[QOV
-I[aQV[\ITTI\QWV

5QKZW.QT\MZ

General Wall Mounted


3. Features & Benefits

< ;+ <;+


< ;0 <;0

; 8 ;  8
; 9 ;  9

General Wall Mounted

II

II

;+ ; +
;0 ; 0

< -+ <-+


< -0 <-0

;6+ ; 60
;60 ;6+
; 6+ ;60

9]QM\7XMZI\QWV

;+;+
;0;0

; ;+ ;;+
; ;0 ;;0

37VTa
.ZM[P

-`KMX\;UIZ\.ZM[P 3
3+WWTQVO7VTa

<ZWXQKIT+WUXZM[[WZ
+

*QO)QZ>WT]UMU

U?QVLJTI[\

U?QVLJTI[\
_Ia;_QVO

_Ia;_QVO

1WV,QNN][MZ

5]T\Q8ZW\MK\QWV.QT\MZ

;\aTQ[P,M[QOV
-I[a
QV[\ITTI\QWV

11

General Wall Mounted


4. Specifications
Models

General Wall Mounted

Cooling Capacity
Heating Capacity
Power Input
Running Current

Cooling
Heating
Cooling
Heating

EER
COP
Power Supply
Power Factor
Indoor,Max
Outdoor,Max
Moisture Removal
Sound Level
Indoor,H/M/L
Outdoor,Max
Refrigerant & Charge (at 5 m)
Additional Refrigerant charge g/m(oz/ft)
Type
Model
Motor Type
Compressor
Oil Type
Oil Charge
O.L.P. name
Type
Fan(Indoor)
Motor Output
Type
Fan(Outdoor)
Motor Type
Motor Output
Circuit Breaker*
Power Supply Cable
Power and Transmission Cable No.*mm2
Liquid Side
Piping Connections
Gas Side
Drain Hose
O.D / I.D
Air Flow Rate

Indoor (W*H*D)
Dimensions
Outdoor (W*H*D)
Net Weight
Operation Range
Max. Piping Length
Max. Elevation Difference
Tool Code(Chassis)

Filter

Functions

Indoor
Outdoor
Cooling(Outdoor)
Heating(Outdoor)

Factory
kW
Btu/h.
kW
Btu/h.
W
W
A
A
W/W
Btu/h.W
W/W
/ V / Hz
%
m3/min(CFM)
3
m /min(CFM)
l/h.
dB(A)3
dB(A)3
g(oz)

cc
W
W
A
No.*mm2
No.*mm2
mm(in)
mm(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
C(F)
C(F)
m(ft)
m(ft)

Indoor + Outdoor
Plasma
NPI
Prefilter(washable/anti-fungus)
Virus+Allergy+Triple(Case)
Virus+Allergy+Triple
Virus+Allergy
Virus+Triple
Smoke Away
3M micro Protection Filter
Triple
Temperature Control
Auto Clean
CHAOS Wind(Auto Wind)
Steps, Fan/Cool/Heat
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Remote Controller Type
Cooling
Setting Temperature
Range
Heating
Temperature Increment
Auto Operation (Micom Control)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Soft Dry Operation
Restart Delay(minute)
Deice Control(Defrost)
Hot Start
Jet Cool
Low Ambient Operation
Hidden Display(88)
Auto Swing / 6Step(Up&Down)
Auto Swing / 6Step(Left&Right)
20m Windblast
Special Function

LS-H382V8C0
9.52
32,500
10.25791325
35,000
3,750
3,600
17.0
16.7
2.54
8.67
2.85
1 / 220 / 60
95
28(989)
60(2,119)
3.3
51/46/42
60
R22, 2500g
50g
ROTARY
QPT525K*
PSC
NM56
1,200
Internal
Cross flow fan
102.6
Axial Fan
AC INDUCTION
119.2
35
3*5.5(Including Earth)
3*0.75(Including Earth)+3*0.75
9.52(3/8)
15.88(5/8)
21.5/16 (0.85/0.63)
1,190*346*265
46.8*13.6*10.4
950*832*330
37.4*32.7*13.0
18.5
71
21~60(69.8~140)
1~24(33.8~75.2)
20(65.6)
15(49.2)
SV+U4
O
O
O
Thermistor
O
O
3/4/4
Auto
Auto
Wireless LCD
18 ~ 30
16C ~ 30C
1
O
O
24h, On/Off
O
O
3
O
O
O
O
O
O
O
-

Note : O : Applie, X : Not applied, : No relation


* For Circuit Breaker Rating, please conform to local standards whenever necessary.
Filters are optional in some specific areas.

12

LS-H382V4B0
9.52
32,500
10.25791325
35,000
3,750
3,600
17.0
16.7
2.54
8.67
2.85
1 / 220 / 60
95
28(989)
60(2,119)
3.3
51/46/42
60
R22, 2500g
50g
ROTARY
QPT525K*
PSC
NM56
1,200
Internal
Cross flow fan
102.6
Axial Fan
AC INDUCTION
119.2
35
3*5.5(Including Earth)
3*0.75(Including Earth)+3*0.75
9.52(3/8)
15.88(5/8)
21.5/16 (0.85/0.63)
1,190*346*265
46.8*13.6*10.4
950*832*330
37.4*32.7*13.0
18.5
71
21~60(69.8~140)
1~24(33.8~75.2)
20(65.6)
15(49.2)
SV+U4
O
Thermistor
O
O
3/4/4
Auto
Auto
Wireless LCD
18 ~ 30
16C ~ 30C
1
O
O
24h, On/Off
O
O
3
O
O
O
O
O
O
O
-

General Wall Mounted


4. Specifications
Models

Heating Capacity
Power Input
Running Current

Cooling
Heating
Cooling
Heating

EER
COP
Power Supply
Power Factor
Indoor,Max
Outdoor,Max
Moisture Removal
Sound Level
Indoor,H/M/L
Outdoor,Max
Refrigerant & Charge (at 5 m)
Additional Refrigerant charge g/m(oz/ft)
Type
Model
Motor Type
Compressor
Oil Type
Oil Charge
O.L.P. name
Type
Fan(Indoor)
Motor Output
Type
Fan(Outdoor)
Motor Type
Motor Output
Circuit Breaker*
Power Supply Cable
Power and Transmission Cable No.*mm2
Liquid Side
Piping Connections
Gas Side
Drain Hose
O.D / I.D
Air Flow Rate

Indoor (W*H*D)
Dimensions
Outdoor (W*H*D)
Net Weight
Operation Range
Max. Piping Length
Max. Elevation Difference
Tool Code(Chassis)

Filter

Functions

Indoor
Outdoor
Cooling(Outdoor)
Heating(Outdoor)

cc
W
W
A
No.*mm2
No.*mm2
mm(in)
mm(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
C(F)
C(F)
m(ft)
m(ft)

Indoor + Outdoor
Plasma
NPI
Prefilter(washable/anti-fungus)
Virus+Allergy+Triple(Case)
Virus+Allergy+Triple
Virus+Allergy
Virus+Triple
Smoke Away
3M micro Protection Filter
Triple
Temperature Control
Auto Clean
CHAOS Wind(Auto Wind)
Steps, Fan/Cool/Heat
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Remote Controller Type
Cooling
Setting Temperature
Range
Heating
Temperature Increment
Auto Operation (Micom Control)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Soft Dry Operation
Restart Delay(minute)
Deice Control(Defrost)
Hot Start
Jet Cool
Low Ambient Operation
Hidden Display(88)
Auto Swing / 6Step(Up&Down)
Auto Swing / 6Step(Left&Right)
20m Windblast
Special Function

LS-H362V4A0
9.38
32,000
10.26
35,000
3,850
3,600
17.5
16.7
2.44
8.31
2.85
1 / 220 / 60
95
28(989)
60(2,119)
3.3
51/46/42
60
R22, 2500g
50g
ROTARY
QPT525K*
PSC
NM56
1,200
Internal
Cross flow fan
102.6
Axial Fan
AC INDUCTION
119.2
35
3*5.5(Including Earth)
3*0.75(Including Earth)+3*0.75
9.52(3/8)
15.88(5/8)
21.5/16 (0.85/0.63)
1,190*346*265
46.8*13.6*10.4
950*832*330
37.4*32.7*13.0
18.5
71
21~54(69.8~129)
1~24(33.8~75.2)
20(65.6)
15(49.2)
SV+U4
O
Thermistor
O
O
3/4/4
Auto
Manual
Wireless LCD
18 30
16C ~ 30C
1
O
O
24h, On/Off
O
O
3
O
O
O
O
O
-

LS-C382V8C0
9.52
32,500
3,820
17.5
2.49
8.51
1 / 220 / 60
95
28(989)
60(2,119)
3.3
51/46/42
60
R22, 2200g
40g
ROTARY
QPT525K*
PSC
NM56
1,200
Internal
Cross flow fan
102.6
Axial Fan
AC INDUCTION
119.2
35
3*5.5(Including Earth)
3*0.75(Including Earth)
9.52(3/8)
15.88(5/8)
21.5/16 (0.85/0.63)
1,190*346*265
46.8*13.6*10.4
950*832*330
37.4*32.7*13.0
18.5
65
21~60(69.8~140)
20(65.6)
15(49.2)
SV+U4
O
O
O
Thermistor
O
O
3/4/Auto
Auto
Wireless LCD
18 30
1
O
O
24h, On/Off
O
O
3
O
O
O
O
O
-

General Wall Mounted

Cooling Capacity

Factory
kW
Btu/h.
kW
Btu/h.
W
W
A
A
W/W
Btu/h.W
W/W
/ V / Hz
%
m3/min(CFM)
3
m /min(CFM)
l/h.
dB(A)3
dB(A)3
g(oz)

Note : O : Applie, X : Not applied, : No relation


* For Circuit Breaker Rating, please conform to local standards whenever necessary.
Filters are optional in some specific areas.

13

General Wall Mounted


4. Specifications
Models

General Wall Mounted

Cooling Capacity
Heating Capacity
Power Input
Running Current

Cooling
Heating
Cooling
Heating

EER
COP
Power Supply
Power Factor
Indoor,Max
Outdoor,Max
Moisture Removal
Sound Level
Indoor,H/M/L
Outdoor,Max
Refrigerant & Charge (at 5 m)
Additional Refrigerant charge g/m(oz/ft)
Type
Model
Motor Type
Compressor
Oil Type
Oil Charge
O.L.P. name
Type
Fan(Indoor)
Motor Output
Type
Fan(Outdoor)
Motor Type
Motor Output
Circuit Breaker*
Power Supply Cable
Power and Transmission Cable No.*mm2
Liquid Side
Piping Connections
Gas Side
Drain Hose
O.D / I.D
Air Flow Rate

Indoor (W*H*D)
Dimensions
Outdoor (W*H*D)
Net Weight
Operation Range
Max. Piping Length
Max. Elevation Difference
Tool Code(Chassis)

Filter

Functions

Indoor
Outdoor
Cooling(Outdoor)
Heating(Outdoor)

Factory
kW
Btu/h.
kW
Btu/h.
W
W
A
A
W/W
Btu/h.W
W/W
/ V / Hz
%
m3/min(CFM)
3
m /min(CFM)
l/h.
dB(A)3
dB(A)3
g(oz)

cc
W
W
A
No.*mm2
No.*mm2
mm(in)
mm(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
C(F)
C(F)
m(ft)
m(ft)

Indoor + Outdoor
Plasma
NPI
Prefilter(washable/anti-fungus)
Virus+Allergy+Triple(Case)
Virus+Allergy+Triple
Virus+Allergy
Virus+Triple
Smoke Away
3M micro Protection Filter
Triple
Temperature Control
Auto Clean
CHAOS Wind(Auto Wind)
Steps, Fan/Cool/Heat
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Remote Controller Type
Cooling
Setting Temperature
Range
Heating
Temperature Increment
Auto Operation (Micom Control)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Soft Dry Operation
Restart Delay(minute)
Deice Control(Defrost)
Hot Start
Jet Cool
Low Ambient Operation
Hidden Display(88)
Auto Swing / 6Step(Up&Down)
Auto Swing / 6Step(Left&Right)
20m Windblast
Special Function

LS-C382V4B0
9.52
32,500
3,820
17.5
2.49
8.51
1 / 220 / 60
95
28(989)
60(2,119)
3.3
51/46/42
60
R22, 2200g
40g
ROTARY
QPT525K*
PSC
NM56
1,200
Internal
Cross flow fan
102.6
Axial Fan
AC INDUCTION
119.2
35
3*5.5(Including Earth)
3*0.75(Including Earth)
9.52(3/8)
15.88(5/8)
21.5/16 (0.85/0.63)
1,190*346*265
46.8*13.6*10.4
950*832*330
37.4*32.7*13.0
18.5
65
21~60(69.8~140)
20(65.6)
15(49.2)
SV+U4
O
O
Thermistor
O
O
3/4/Auto
Auto
Wireless LCD
18 30
1
O
O
24h, On/Off
O
O
3
O
O
O
O
O
-

Note : O : Applie, X : Not applied, : No relation


* For Circuit Breaker Rating, please conform to local standards whenever necessary.
Filters are optional in some specific areas.

14

LS-C362V4A0
9.38
32,000
3,850
17.5
2.44
8.31
1 / 220 / 60
95
28(989)
60(2,119)
3.3
51/46/42
60
R22, 2300g
40g
ROTARY
QPT525K*
PSC
NM56
1,200
Internal
Cross flow fan
102.6
Axial Fan
AC INDUCTION
119.2
35
3*5.5(Including Earth)
3*0.75(Including Earth)
9.52(3/8)
15.88(5/8)
21.5/16 (0.85/0.63)
1,190*346*265
46.8*13.6*10.4
950*832*330
37.4*32.7*13.0
18.5
65
21~54(69.8~129)
20(65.6)
15(49.2)
SV+U4
O
Thermistor
O
O
3/4/Auto
Manual
Wireless LCD
18 30
1
O
O
24h, On/Off
O
O
3
O
O
O
-

General Wall Mounted


4. Specifications
Models

Heating Capacity
Power Input
Running Current

Cooling
Heating
Cooling
Heating

EER
COP
Power Supply
Power Factor
Indoor,Max
Outdoor,Max
Moisture Removal
Sound Level
Indoor,H/M/L
Outdoor,Max
Refrigerant & Charge (at 5 m)
Additional Refrigerant charge g/m(oz/ft)
Type
Model
Motor Type
Compressor
Oil Type
Oil Charge
O.L.P. name
Type
Fan(Indoor)
Motor Output
Type
Fan(Outdoor)
Motor Type
Motor Output
Circuit Breaker*
Power Supply Cable
Power and Transmission Cable No.*mm2
Liquid Side
Piping Connections
Gas Side
Drain Hose
O.D / I.D
Air Flow Rate

Indoor (W*H*D)
Dimensions
Outdoor (W*H*D)
Net Weight
Operation Range
Max. Piping Length
Max. Elevation Difference
Tool Code(Chassis)

Filter

Functions

Indoor
Outdoor
Cooling(Outdoor)
Heating(Outdoor)

cc
W
W
A
No.*mm2
No.*mm2
mm(in)
mm(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
C(F)
C(F)
m(ft)
m(ft)

Indoor + Outdoor
Plasma
NPI
Prefilter(washable/anti-fungus)
Virus+Allergy+Triple(Case)
Virus+Allergy+Triple
Virus+Allergy
Virus+Triple
Smoke Away
3M micro Protection Filter
Triple
Temperature Control
Auto Clean
CHAOS Wind(Auto Wind)
Steps, Fan/Cool/Heat
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Remote Controller Type
Cooling
Setting Temperature
Range
Heating
Temperature Increment
Auto Operation (Micom Control)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Soft Dry Operation
Restart Delay(minute)
Deice Control(Defrost)
Hot Start
Jet Cool
Low Ambient Operation
Hidden Display(88)
Auto Swing / 6Step(Up&Down)
Auto Swing / 6Step(Left&Right)
20m Windblast
Special Function

LS-H322V8C0
8.65
29,500
9.38
32,000
3,450
3,200
16.0
15.0
2.51
8.55
2.93
1 / 220 / 60
95
23(812)
54 (1.907)
2.8
48/44/40
60
R22, 2400g
50g
ROTARY
QPT488K*
PSC
NM56
1,200
Internal
Cross flow fan
82.1
Axial Fan
AC INDUCTION
72
30
3*5.5(Including Earth)
3*0.75(Including Earth)+3*0.75
9.52(3/8)
15.88(5/8)
21.5/16 (0.85/0.63)
1,190*346*265
46.8*13.6*10.4
870*808*320
34.3*31.8*12.6
18.5
66
21~60(69.8~140)
1~24(33.8~75.2)
20(65.6)
15(49.2)
SV+UE1
O
O
O
Thermistor
O
O
3/4/4
Auto
Auto
Wireless LCD
18 30
16C ~ 30C
1
O
O
24h, On/Off
O
O
3
O
O
O
O
O
O
O
-

LS-H322V4B0
8.65
29,500
9.38
32,000
3,450
3,200
16.0
15.0
2.51
8.55
2.93
1 / 220 / 60
95
23(812)
54 (1.907)
2.8
48/44/40
60
R22, 2400g
50g
ROTARY
QPT488K*
PSC
NM56
1,200
Internal
Cross flow fan
82.1
Axial Fan
AC INDUCTION
72
30
3*5.5(Including Earth)
3*0.75(Including Earth)+3*0.75
9.52(3/8)
15.88(5/8)
21.5/16 (0.85/0.63)
1,190*346*265
46.8*13.6*10.4
870*808*320
34.3*31.8*12.6
18.5
66
21~60(69.8~140)
1~24(33.8~75.2)
20(65.6)
15(49.2)
SV+UE1
O
O

General Wall Mounted

Cooling Capacity

Factory
kW
Btu/h.
kW
Btu/h.
W
W
A
A
W/W
Btu/h.W
W/W
/ V / Hz
%
m3/min(CFM)
3
m /min(CFM)
l/h.
dB(A)3
dB(A)3
g(oz)

Thermistor
O
O
3/4/3
Auto
Auto
Wireless LCD
18 30
16C ~ 30C
1
O
O
24h, On/Off
O
O
3
O
O
O
O
O
O
O
-

Note : O : Applie, X : Not applied, : No relation


* For Circuit Breaker Rating, please conform to local standards whenever necessary.
Filters are optional in some specific areas.

15

General Wall Mounted


4. Specifications
Models

General Wall Mounted

Cooling Capacity
Heating Capacity
Power Input
Running Current

Cooling
Heating
Cooling
Heating

EER
COP
Power Supply
Power Factor
Indoor,Max
Outdoor,Max
Moisture Removal
Sound Level
Indoor,H/M/L
Outdoor,Max
Refrigerant & Charge (at 5 m)
Additional Refrigerant charge g/m(oz/ft)
Type
Model
Motor Type
Compressor
Oil Type
Oil Charge
O.L.P. name
Type
Fan(Indoor)
Motor Output
Type
Fan(Outdoor)
Motor Type
Motor Output
Circuit Breaker*
Power Supply Cable
Power and Transmission Cable No.*mm2
Liquid Side
Piping Connections
Gas Side
Drain Hose
O.D / I.D
Air Flow Rate

Indoor (W*H*D)
Dimensions
Outdoor (W*H*D)
Net Weight
Operation Range
Max. Piping Length
Max. Elevation Difference
Tool Code(Chassis)

Filter

Functions

Indoor
Outdoor
Cooling(Outdoor)
Heating(Outdoor)

Factory
kW
Btu/h.
kW
Btu/h.
W
W
A
A
W/W
Btu/h.W
W/W
/ V / Hz
%
m3/min(CFM)
3
m /min(CFM)
l/h.
dB(A)3
dB(A)3
g(oz)

cc
W
W
A
No.*mm2
No.*mm2
mm(in)
mm(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
C(F)
C(F)
m(ft)
m(ft)

Indoor + Outdoor
Plasma
NPI
Prefilter(washable/anti-fungus)
Virus+Allergy+Triple(Case)
Virus+Allergy+Triple
Virus+Allergy
Virus+Triple
Smoke Away
3M micro Protection Filter
Triple
Temperature Control
Auto Clean
CHAOS Wind(Auto Wind)
Steps, Fan/Cool/Heat
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Remote Controller Type
Cooling
Setting Temperature
Range
Heating
Temperature Increment
Auto Operation (Micom Control)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Soft Dry Operation
Restart Delay(minute)
Deice Control(Defrost)
Hot Start
Jet Cool
Low Ambient Operation
Hidden Display(88)
Auto Swing / 6Step(Up&Down)
Auto Swing / 6Step(Left&Right)
20m Windblast
Special Function

LS-C382V8C0
8.21
28,000
9.38
32,000
3,450
3,200
16.5
15.3
2.38
8.12
2.93
1 / 220 / 60
95
23(812)
54 (1.907)
2.8
48/44/40
60
R22, 2400g
50g
ROTARY
QPT488K*
PSC
NM56
1,200
Internal
Cross flow fan
82.1
Axial Fan
AC INDUCTION
72
30
3*5.5(Including Earth)
3*0.75(Including Earth)+3*0.75
9.52(3/8)
15.88(5/8)
21.5/16 (0.85/0.63)
1,190*346*265
46.8*13.6*10.4
870*808*320
34.3*31.8*12.6
18.5
66
21~54(69.8~129)
1~24(33.8~75.2)
20(65.6)
15(49.2)
SV+UE1
O
Thermistor
O
O
3/4/4
Auto
Manual
Wireless LCD
18 30
16C ~ 30C
1
O
O
24h, On/Off
O
O
3
O
O
O
O
O
-

Note : O : Applie, X : Not applied, : No relation


* For Circuit Breaker Rating, please conform to local standards whenever necessary.
Filters are optional in some specific areas.

16

LS-C322V8C0
8.79
30,000
3,500
16.0
2.51
8.57
1 / 220 / 60
95
23(812)
54 (1.907)
2.8
48/44/40
60
R22, 1650g
35g
ROTARY
QPT464K*
PSC
NM56
1,200
Internal
Cross flow fan
82.1
Axial Fan
AC INDUCTION
72
30
3*5.5(Including Earth)
3*0.75(Including Earth)
9.52(3/8)
15.88(5/8)
21.5/16 (0.85/0.63)
1,190*346*265
46.8*13.6*10.4
870*655*320
34.3*25.8*12.6
18.5
56
21~60(69.8~140)
20(65.6)
15(49.2)
SV+UE
O
O
O
Thermistor
O
O
3/4/Auto
Auto
Wireless LCD
18 30
1
O
O
24h, On/Off
O
O
3
O
O
O
O
O
-

General Wall Mounted


4. Specifications
Models

Heating Capacity
Power Input
Running Current

Cooling
Heating
Cooling
Heating

EER
COP
Power Supply
Power Factor
Indoor,Max
Outdoor,Max
Moisture Removal
Sound Level
Indoor,H/M/L
Outdoor,Max
Refrigerant & Charge (at 5 m)
Additional Refrigerant charge g/m(oz/ft)
Type
Model
Motor Type
Compressor
Oil Type
Oil Charge
O.L.P. name
Type
Fan(Indoor)
Motor Output
Type
Fan(Outdoor)
Motor Type
Motor Output
Circuit Breaker*
Power Supply Cable
Power and Transmission Cable No.*mm2
Liquid Side
Piping Connections
Gas Side
Drain Hose
O.D / I.D
Air Flow Rate

Indoor (W*H*D)
Dimensions
Outdoor (W*H*D)
Net Weight
Operation Range
Max. Piping Length
Max. Elevation Difference
Tool Code(Chassis)

Filter

Functions

Indoor
Outdoor
Cooling(Outdoor)
Heating(Outdoor)

cc
W
W
A
No.*mm2
No.*mm2
mm(in)
mm(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
C(F)
C(F)
m(ft)
m(ft)

Indoor + Outdoor
Plasma
NPI
Prefilter(washable/anti-fungus)
Virus+Allergy+Triple(Case)
Virus+Allergy+Triple
Virus+Allergy
Virus+Triple
Smoke Away
3M micro Protection Filter
Triple
Temperature Control
Auto Clean
CHAOS Wind(Auto Wind)
Steps, Fan/Cool/Heat
Airflow Direction Control(up & Down)
Airflow Direction Control(left & right)
Remote Controller Type
Cooling
Setting Temperature
Range
Heating
Temperature Increment
Auto Operation (Micom Control)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Soft Dry Operation
Restart Delay(minute)
Deice Control(Defrost)
Hot Start
Jet Cool
Low Ambient Operation
Hidden Display(88)
Auto Swing / 6Step(Up&Down)
Auto Swing / 6Step(Left&Right)
20m Windblast
Special Function

LS-C322V4B0
8.79
30,000
3,500
16.0
2.51
8.57
1 / 220 / 60
95
23(812)
54 (1.907)
2.8
48/44/40
60
R22, 1650g
35g
ROTARY
QPT464K*
PSC
NM56
1,200
Internal
Cross flow fan
82.1
Axial Fan
AC INDUCTION
72
30
3*5.5(Including Earth)
3*0.75(Including Earth)
9.52(3/8)
15.88(5/8)
21.5/16 (0.85/0.63)
1,190*346*265
46.8*13.6*10.4
870*655*320
34.3*25.8*12.6
18.5
56
21~60(69.8~140)
20(65.6)
15(49.2)
SV+UE
O
O
Thermistor
O
O
3/4/Auto
Auto
Wireless LCD
18 30
1
O
O
24h, On/Off
O
O
3
O
O
O
O
O
-

LS-C302V4A0
8.21
28,000
3,500
16.0
2.34
8.00
1 / 220 / 60
95
23(812)
54 (1.907)
2.8
48/44/40
60
R22, 1650g
35g
ROTARY
QPT464K*
PSC
NM56
1,200
Internal
Cross flow fan
82.1
Axial Fan
AC INDUCTION
72
30
3*5.5(Including Earth)
3*0.75(Including Earth)
9.52(3/8)
15.88(5/8)
21.5/16 (0.85/0.63)
1,190*346*265
46.8*13.6*10.4
870*655*320
34.3*25.8*12.6
18.5
56
21~54(69.8~129)
20(65.6)
15(49.2)
SV+UE
O
Thermistor
O
O
3/4/Auto
Manual
Wireless LCD
18 30
1
O
O
24h, On/Off
O
O
3
O
O
O
-

General Wall Mounted

Cooling Capacity

Factory
kW
Btu/h.
kW
Btu/h.
W
W
A
A
W/W
Btu/h.W
W/W
/ V / Hz
%
m3/min(CFM)
3
m /min(CFM)
l/h.
dB(A)3
dB(A)3
g(oz)

Note : O : Applie, X : Not applied, : No relation


* For Circuit Breaker Rating, please conform to local standards whenever necessary.
Filters are optional in some specific areas.

17

18
Right rear piping

43

167

Left rear piping

Installation plate

Unit Outline

140

43

167

150

[Unit : mm]

CHASSIS CODE: SV

General Wall Mounted

General Wall Mounted


5. Dimensional drawings

5.1 Indoor Units

General Wall Mounted


5. Dimensional drawings
5.2 Outdoor Unit

[Unit : mm]

CHASSIS CODE: U4

General Wall Mounted

19

20
1

Control Box
Earth Screw

4
5

Remark

CHASSIS CODE: UE

Unit : mm

1. The unit should be installed according to installation manual which is


in the product box.
2. In an area or a apace having no proper air circulation, an air guide
should be installed in the outdoor unit.

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea
www.lge.com/airconditioner

[Unit : mm]

Liquid Pipe Connection Port

Note

Gas Pipe Connection Port

Part Name
Air Dicharge Grille

No.

General Wall Mounted

General Wall Mounted


5. Dimensional drawings

301

546

319

25

800

31

16 0

54 .6

340
79

320

Note

Remark

CHASSIS CODE: UE1

Unit : mm

1. The unit should be installed according to installation manual which is


in the product box.
2. In an area or a apace having no proper air circulation, an air guide
should be installed in the outdoor unit.

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea
www.lge.com/airconditioner

[Unit : mm]

Control Box

4
Earth Screw

Liquid Pipe Connection Port

Gas Pipe Connection Port

Part Name
Air Dicharge Grille

No.

General Wall Mounted

870

General Wall Mounted


5. Dimensional drawings

21

360

76.4

General Wall Mounted


6. Wiring diagrams
General Wall Mounted

6.1 Indoor units


Model: LS-H382V8C0, LS-H382V4B0, LS-H362V4A0, LS-H322V8C0, LS-H322V4B0, LS-H302V4A0

Model: LS-C382V8C0, LS-C382V4B0, LS-C362V4A0, LS-C322V8C0, LS-C322V4B0, LS-C302V4A0

22

General Wall Mounted


6. Wiring diagrams
6.2 Outdoor units
General Wall Mounted

Model: LS-H382V8C0, LS-H382V4B0, LS-H362V4A0

Model: LS-H322V8C0, LS-H322V4B0, LS-H302V4A0

23

General Wall Mounted


6. Wiring diagrams
General Wall Mounted

Model: LS-C382V8C0, LS-C382V4B0, LS-C362V4A0

Model: LS-C322V8C0, LS-C322V4B0, LS-C302V4A0

24

General Wall Mounted


7. Refrigerant cycle Diagram
n Cooling only Model
Outdoor Unit

Liquid Side

Th2

General Wall Mounted

Indoor Unit

Capillary Tube

3-Way Valve

Th1

Heat
Exchanger
(Evaporator)

Heat
Exchanger
(Condenser)

Gas Side
3-Way Valve

LOC.

Compressor

Description

PCB Connector

Th1

Thermistor for indoor air temperature

Th2

Thermistor for evaporating temperature

CN-TH1

n Heat pump Model


Indoor Unit

Outdoor Unit
Check Valve
(Heating Model only)

Liquid Side

Th2

3-Way Valve

Th1

Capillary Tube

Heat
Exchanger
(Evaporator)

Heat
Exchanger
(Condenser)

Gas Side
Reversing Valve

3-Way Valve
Accumulator

LOC.

Description

Th1

Thermistor for indoor air temperature

Th2

Thermistor for evaporating temperature

Cooling
Heating

Compressor

PCB Connector
CN-TH1

25

General Wall Mounted


8. Capacity tables
General Wall Mounted

8.1 Cooling Capacity


Model: LS-H382V8C0,LS-H382V4B0,LS-C382V8C0,LS-C382V4B0
Outdoor Air Temperature : CDB

Indoor Air
Temperature

20

25
PI

TC

32
PI

TC

35
PI

40
TC

43
PI

TC

46
PI

TC

50
PI

TC

54

CWB

CDB

TC

TC

PI

14

20

7.73

2.46 7.56

2.91 7.21 3.40

6.99

3.58 6.73

3.80 6.51

3.93 6.27

4.04 5.91 4.18

PI

5.51 4.30

TC

PI

16

22

9.01

2.49 8.82

2.96 8.41 3.45

8.16

3.63 7.85

3.86 7.60

3.99 7.31

4.11 6.89 4.24

6.42 4.37

18

25

10.06 2.53 9.84

3.00 9.38 3.50

9.10

3.69 8.76

3.92 8.48

4.05 8.16

4.17 7.69 4.31

7.17 4.43

19

27

10.53 2.58 10.30 3.05 9.82 3.56

9.52

3.75 9.17

3.99 8.87

4.12 8.54

4.24 8.05 4.38

7.50 4.51

22

30

11.55 2.61 11.31 3.09 10.77 3.61 10.45 3.80 10.06 4.04 9.73

4.17 9.37

4.29 8.83 4.44

8.23 4.57

24

32

11.99 2.65 11.73 3.14 11.18 3.66 10.85 3.85 10.44 4.10 10.1

4.23 9.73

4.36 9.17 4.50

8.54 4.63

Model: LS-H362V4A0,LS-C362V4A0
Outdoor Air Temperature : CDB

Indoor Air
Temperature

20

25
PI

TC

32
PI

TC

35
PI

40
TC

43
PI

TC

46
PI

TC

50
PI

TC

54

CWB

CDB

TC

TC

PI

14

20

7.61

2.52 7.45

2.99 7.09 3.49

6.88

3.67 6.63

3.91 6.41

4.04 6.17

4.15 5.82 4.29

PI

5.42 4.42

TC

PI

16

22

8.88

2.56 8.69

3.04 8.28 3.54

8.03

3.73 7.73

3.97 7.48

4.10 7.20

4.22 6.79 4.36

6.33 4.48

18

25

9.90

2.60 9.69

3.08 9.24 3.59

8.96

3.79 8.63

4.03 8.35

4.16 8.03

4.28 7.57 4.42

7.06 4.55

19

27

10.36 2.64 10.14 3.13 9.67 3.65

9.38

3.85 9.03

4.10 8.73

4.23 8.41

4.35 7.92 4.50

7.39 4.63

22

30

11.37 2.68 11.13 3.17 10.61 3.70 10.29 3.90 9.91

4.15 9.59

4.28 9.23

4.41 8.70 4.56

8.11 4.69

24

32

11.80 2.72 11.55 3.22 11.01 3.76 10.68 3.96 10.28 4.21 9.95

4.35 9.58

4.47 9.03 4.62

8.41 4.76

Model: LS-H322V8C0,LS-H322V4B0
Outdoor Air Temperature : CDB

Indoor Air
Temperature

20

25

CWB

CDB

TC

PI

TC

14

20

7.01

2.26 6.86

16

22

8.18

18

25

9.13

TC

PI

40
TC

43
PI

TC

46
PI

TC

50
PI

TC

54

TC

PI

2.68 6.54 3.12

6.35

3.29 6.11

3.50 5.91

3.62 5.69

3.72 5.36 3.85

5.00 3.96

2.30 8.01

2.72 7.63 3.17

7.40

3.34 7.13

3.55 6.89

3.67 6.64

3.78 6.26 3.91

5.83 4.02

2.33 8.94

2.76 8.52 3.22

8.26

3.39 7.95

3.61 7.69

3.73 7.41

3.84 6.98 3.96

6.51 4.08

PI

TC

PI

2.37 9.35

19

27

9.55

2.81 8.91 3.28

8.65

3.45 8.32

3.67 8.05

3.79 7.75

3.90 7.31 4.03

6.81 4.15

22

30

10.49 2.40 10.26 2.84 9.78 3.32

9.49

3.49 9.14

3.72 8.84

3.84 8.51

3.95 8.02 4.08

7.47 4.20

24

32

10.88 2.44 10.65 2.89 10.15 3.37

9.85

3.55 9.48

3.77 9.17

3.90 8.83

4.01 8.32 4.14

7.76 4.26

Symbol
DB : Dry Bulb Temperature
WB: Wet Bulb Temperature
TC : Total Capacity
PI : Power Input
(Comp.+ indoor fan motor + outdoor fan motor)

26

35

32
PI

Notes
[C]
[C]
[kW]
[kW]

1. All capacities are net, evaporator fan motor heat is deducted.


2.
Indicates nominal maximum capacity.
3. Direct interpolation is permissible. Do not extrapolate.
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.

General Wall Mounted


8. Capacity tables
General Wall Mounted

Model: LS-C322V8C0,LS-C322V4B0
Outdoor Air Temperature : CDB

Indoor Air
Temperature

20

25
PI

TC

32
PI

TC

35
PI

40
TC

43
PI

TC

46
PI

TC

50
PI

TC

54

CWB

CDB

TC

TC

PI

14

20

7.13

2.29 6.98

2.72 6.65 3.17

6.45

3.34 6.21

3.55 6.01

3.67 5.78

3.77 5.45 3.90

PI

5.08 4.01

TC

PI

16

22

8.32

2.33 8.14

2.76 7.76 3.22

7.53

3.39 7.25

3.61 7.01

3.72 6.75

3.83 6.36 3.96

5.93 4.08

18

25

9.28

2.36 9.09

2.80 8.66 3.27

8.40

3.44 8.09

3.66 7.82

3.78 7.53

3.89 7.10 4.02

6.62 4.14

19

27

9.72

2.40 9.51

2.85 9.06 3.32

8.79

3.50 8.47

3.72 8.19

3.85 7.88

3.96 7.43 4.09

6.93 4.21

22

30

10.66 2.43 10.44 2.89 9.95 3.37

9.65

3.54 9.29

3.77 8.99

3.90 8.65

4.01 8.15 4.14

7.60 4.26

24

32

11.07 2.47 10.83 2.93 10.32 3.41 10.01 3.60 9.64

3.83 9.33

3.95 8.98

4.07 8.46 4.20

7.89 4.32

Model: LS-H302V4A0,LS-C302V4A0
Outdoor Air Temperature : CDB

Indoor Air
Temperature

20

25
PI

TC

32
PI

TC

35

PI

TC

46
PI

TC

50
PI

TC

54

CDB

TC

TC

PI

14

20

6.66

2.26 6.51

2.68 6.21 3.12

6.02

3.29 5.80

3.50 5.61

3.62 5.40

3.72 5.09 3.85

4.74 3.96

16

22

7.77

2.30 7.60

2.72 7.24 3.17

7.03

3.34 6.77

3.55 6.54

3.67 6.30

3.78 5.94 3.91

5.54 4.02

18

25

8.67

2.33 8.48

2.76 8.08 3.22

7.84

3.39 7.55

3.61 7.30

3.73 7.03

3.84 6.63 3.96

6.18 4.08

19

27

9.07

2.37 8.88

2.81 8.46 3.28

8.21

3.45 7.90

3.67 7.64

3.79 7.36

3.90 6.93 4.03

6.46 4.15

22

30

9.95

2.40 9.74

2.84 9.28 3.32

9.01

3.49 8.67

3.72 8.39

3.84 8.07

3.95 7.61 4.08

7.09 4.20

24

32

10.33 2.44 10.11 2.89 9.63 3.37

9.35

3.55 9.00

3.77 8.70

3.90 8.38

4.01 7.90 4.14

7.36 4.26

DB : Dry Bulb Temperature


WB: Wet Bulb Temperature
TC : Total Capacity
PI : Power Input
(Comp.+ indoor fan motor + outdoor fan motor)

TC

43

CWB

Symbol

PI

40

PI

TC

PI

Notes
[C]
[C]
[kW]
[kW]

1. All capacities are net, evaporator fan motor heat is deducted.


2.
Indicates nominal maximum capacity.
3. Direct interpolation is permissible. Do not extrapolate.
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.

27

General Wall Mounted


8. Capacity tables
General Wall Mounted

8.2 Heating Capacity


Model: LS-H382V8C0,LS-H382V4B0,LS-H362V4A0
Outdoor Air Temperature : WB

Indoor Air
Temperature ()

-10

-5

TC

10
PI

TC

15

DB

TC

PI

TC

PI

TC

PI

TC

PI

PI

TC

PI

TC

PI

16

6.93

2.62

8.17

2.87

9.45

3.12

9.93

3.22 10.40

3.32

10.99

3.37 11.90

3.55

13.13

3.80

18

6.71

2.71

7.91

2.97

9.15

3.23

9.61

3.33 10.07

3.43

10.64

3.49 11.52

3.67

12.72

3.93

20

6.51

2.80

7.67

3.06

8.88

3.34

9.33

3.44

9.77

3.54

10.26

3.60 11.18

3.79

12.34

4.06

22

6.28

2.89

7.40

3.16

8.56

3.44

8.99

3.55

9.42

3.65

9.95

3.72 10.77

3.91

11.89

4.19

24

6.06

2.98

7.14

3.26

8.26

3.55

8.68

3.66

9.10

3.77

9.61

3.83 10.40

4.03

11.48

4.32

Model: LS-H322V8C0,LS-H322V4B0,LS-H302V4A0
Outdoor Air Temperature : WB

Indoor Air
Temperature ()

-10

-5

DB

TC

PI

TC

PI

TC

PI

TC

PI

TC

PI

TC

16

6.34

2.33

7.47

2.55

8.64

2.78

9.08

2.86

9.51

2.95

10.05

18

6.14

2.41

7.23

2.64

8.37

2.87

8.79

2.96

9.21

3.05

9.73

20

5.96

2.49

7.02

2.72

8.12

2.97

8.53

3.06

8.93

3.15

22

5.74

2.57

6.76

2.81

7.83

3.06

8.22

3.15

8.61

24

5.54

2.65

6.53

2.90

7.56

3.15

7.94

3.25

8.32

Symbol
DB : Dry Bulb Temperature
WB: Wet Bulb Temperature
TC : Total Capacity
PI : Power Input
(Comp.+ Indoor fan motor + Outdoor fan motor)

28

10
PI

TC

15
PI

TC

PI

3.00 10.88

3.16

12.01

3.38

3.10 10.53

3.26

11.63

3.50

9.38

3.20 10.22

3.37

11.28

3.61

3.25

9.10

3.30

9.85

3.48

10.87

3.73

3.35

8.79

3.41

9.51

3.59

10.50

3.84

Notes
[C]
[C]
[kW]
[kW]

1. All capacities are net, evaporator fan motor heat is deducted.


2.
Indicates nominal maximum capacity.
3. Direct interpolation is permissible. Do not extrapolate.
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.
- Outdoor air : 85%RH. However, the condition on nominal
capacity is 7CDB/6CWB.

General Wall Mounted


9. Capacity coefficient factor
General Wall Mounted

Model: LS-H382V8C0, LS-H382V4B0, LS-H362V4A,0 LS-C382V8C0, LS-C382V4B0, LS-C362V4A0


n Cooling
Pipe Size

Capacity

Max.
Elevation m

Max.
Length m

Additional
Refrigerant (g/m)

[Btu/h]

GAS

LIQUID

Standard
Length(m)

30k - 32k

5/8"

3/8"

15

20

35

Max.
Elevation m

Max.
Length m

Additional
Refrigerant (g/m)

15

20

60

n Heating
Pipe Size

Capacity
[Btu/h]

GAS

LIQUID

Standard
Length(m)

30k - 32k

5/8"

3/8"

Indoor unit

Outdoor unit

A
B

Outdoor unit

A
Indoor unit

Outdoor unit

Oil trap
B

Indoor unit

If piping length is more than 5m

CAUTION
Capacity is based on standard length and maximum allowance length is on the basis of reliability. Oil trap should be installed
every 5~7 meters.

29

General Wall Mounted


9. Capacity coefficient factor
General Wall Mounted

Model: LS-H322V8C0, LS-H322V4B0, LS-H302V4A0, LS-C322V8C0, LS-C322V4B0, LS-C302V4A0


n Cooling
Pipe Size

Capacity

Max.
Elevation m

Max.
Length m

Additional
Refrigerant (g/m)

[Btu/h]

GAS

LIQUID

Standard
Length (m)

36k, 38k

5/8"

3/8"

15

20

40

n Heating
Pipe Size

Capacity
[Btu/h]

GAS

LIQUID

Standard
Length (m)

Max.
Elevation m

Max.
Length m

Additional
Refrigerant (g/m)

36k, 38k

5/8"

3/8"

15

20

50

Indoor unit

Outdoor unit

A
B

Outdoor unit

A
Indoor unit

CAUTION
Capacity is based on standard length and maximum allowance length is on the basis of reliability.

30

General Wall Mounted


10. Air Velocity and Temperature Distribution

Cooling

Heating

Discharge angle: 135

Discharge angle: 125

Air velocity [m/s]

Air velocity [m/s]


2.7m

2.7m

2m

2m

1m

12m

5.0

1.5
10m

8m

6m

4.0

3.0
4m

1m

4.0

4.5

1.0
14m

General Wall Mounted

Model: LS-H362V4A0, LS-C362V4A0

0m
0m

2m

Temperature [C]

1.0
14m

12m

1.5
10m

8m

2.5

2.0
6m

4m

0m
0m

2m

Temperature [C]
2.7m

2.7m

2m

2m

18
32

1m

24
14m

12m

10m

8m

22
6m

4m

20
2m

0m
0m

24
14m

12m

10m

26
8m

6m

1m

30
28
4m

2m

0m
0m

31

General Wall Mounted


11. Remote controller
General Wall Mounted

Wireless remote control

Display
screen

Control
panel

Display
screen

Description
On/Off button: Turns the power on/off.
Temperature adjustment buttons:
Adjusts the room temperature when cooling
and heating.
Operation mode selection button*:

A C Selects the operation mode.


D B Cooling operation (A) / Auto operation or auto
changeover (C) / Dehumidifying operation (D) /
E
Heating operation (B) / Air circulation (E)

Control
panel

fan speed button: Adjusts the fan


7 v Indoor
speed.

Jet cooling/heating button*: Warms up or


cools down the indoor temperature within a
short period of time.
Functions button*: Sets the special functions.

J: Auto clean,
G: Operates energy saving cooling
G \ : Adjusts the brightness of the
indoor unit display

Smoke Away button*: Purifies the air by


removing particles that enter the indoor unit.

Air circulation button*: Used to circulate the


room air without cooling or heating.

DE

* The icon can be changed


according to type of model.

J
G
-

Air flow direction button: Adjusts the air flow

H I direction vertically or horizontally.

Temperature display button: Displays the


room temperature.

Sleep mode auto button*: Sets the sleep


mode auto operation.

mn z

Timer button: Sets the current time and the


start / end time.

Set/clear button: Sets or cancels functions.

Reset button: Initialize the air conditioner


settings.

* Some functions may not be supported, depending on the model.

32

General Wall Mounted


12. Installation
General Wall Mounted

Installation Map

Installation plate
Sleeve
Bushing-Sleeve
Putty(Gum Type Sealant)
Bend the pipe as closely
on the wall as possible,
but be careful that it
doesn't break.

Air Discharge

Operation Indication Lamps/


Signal Receptor
Forced Operation Button
Saddle

Air Inlet Vents

Vinyl tape (Wide)


Apply after carrying out a
drainage test.
To carry out the drainage
test, remove the air filters
and pour water into the heat
exchanger.

Gas side piping


(Optional Parts)
Liquid side piping
(Optional Parts)
Additional drain pipe

Air Outlet Vents

Base Plate

Vinyl tape (Narrow)


Drain Hose
Connecting cable
(Optional Parts)

* The feature can be changed according to a type of model.


NOTE : Installation parts you should purchase.

33

General Wall Mounted


12. Installation
General Wall Mounted

Select the best Location


Indoor unit
1. Do not have any heat or steam near the unit.
2. Select a place where there are no obstacles in front of the
unit.

More than
100mm

More than 200mm

3. Make sure that condensation drainage can be conveniently


routed away.

More than
100mm

4. Do not install near a doorway.


5. Ensure that the interval between a wall and the left (or
right) of the unit is more than 100mm. The unit should be
installed as high as possible on the wall, allowing a
minimum of 200mm from ceiling.

More than 2300mm


(Unit : mm)

6. Use a stud finder to locate studs to prevent unnecessary


damage to the wall.

CAUTION
Install the indoor unit on the wall where the height from the floor is more than 2300mm.

Outdoor unit
1. If an awning is built over the unit to prevent direct sunlight
or rain exposure, make sure that heat radiation from the
condenser is not restricted.
2. Ensure that the space around the back and sides is more
than 300mm. The front of the unit should have more than
700mm of space.

More than 600mm


More than 300mm
More than
300mm
More
than 600mm

3. Do not place animals and plants in the path of the warm


air.
4. Take the weight of the air conditioner into account and
select a place where noise and vibration are minimum.
5. Select a place where the warm air and noise from the air
conditioner do not disturb neighbors..

34

More than 700mm

General Wall Mounted


12. Installation
General Wall Mounted

Installation guide at the seaside

CAUTION
1. Air conditioners should not be installed in areas where corrosive gases, such as acid or alkaline gas, are produced.
2. Do not install the product where it could be exposed to sea wind (salty wind) directly. It can result corrosion on the
product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient
performance.
3. If outdoor unit is installed close to the seaside, it should avoid direct exposure to the sea wind. Otherwise it needs
additional anticorrosion treatment on the heat exchanger.

Selecting the location(Outdoor Unit)


1) If the outdoor unit is to be installed close to the seaside, direct exposure to the sea wind should be avoided. Install the
outdoor unit on the opposite side of the sea wind direction.

Sea wind

Sea wind

2) In case, to install the outdoor unit on the seaside, set up a windbreak not to be exposed to the sea wind.

Windbreak

Sea wind

- It should be strong enough like concrete to prevent the


sea wind from the sea.
- The height and width should be more than 150% of the
outdoor unit.
- More than 70cm(s) of space should be kept between outdoorunit and windbreak for easy air flow.

3) Select a well-drained place.


1. If you cant meet above guide line in the seaside installation, please contact LG Electronics for the additional
anticorrosion.
2. Periodic ( more than once/year ) cleaning of the dust or salt particles stuck on the heat exchanger by using
water.

35

P/No.: MFL67839906

Air Conditioner
20 Yeouido-dong, Yeongdeungpo-gu,
Yeouido P.O.Box 335 Seoul,
150-721, Korea.
http://www.lgeaircon.com

All rights reserved


Printed in Korea April / 2013
The specifications, designs, and
information in this brochure are subject to
change without notice.