Water cooling
Water cooling system is arranged both on upper deck and in the engine room. Water cooling
pipes on upper deck shall be insulated against freezing. For The pipes that are inside the
Engine Room, no heat tracing or freezing and insulation is foreseen required as ambient
temperature is over the freezing limit. The ambient temperature inside E.R being over the
freezing limit and pipes on upper deck will be insulated.
Compressed Air, Tank Vent and Sounding
These pipes Normally these pipes do not normally come into contact with liquid, either inside
or outside, so insulation is not required. and it is not necessary to be insulated these pipes.
Formatted: Normal
FIRE FIGHTING
The fire fightingfirefighting take-off branches of ND 3" to 8" should be heat loss protected
with insulation for pipes below 3" insulation and electrical heat tracing (anti-ex for zone 1, ii
b/t3) shall be provided.
The pipes on deluge valve skid outlet are normally empty and no freezing protection is
required