Sunteți pe pagina 1din 12

Product Data Sheet

PS00232
April 2002

Micro Motion Flowmeters


Specification Summary

www.micromotion.com

Contents

Micro Motion Coriolis


flowmeters

Micro Motion Coriolis flowmeters . . . . . . . . . . . . . . 2


Sensors overview . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Transmitters overview . . . . . . . . . . . . . . . . . . . . . . . 4
Sensor features comparison . . . . . . . . . . . . . . . . . . 5
Transmitter features comparison . . . . . . . . . . . . . . . 6
Accuracy specifications on liquids and slurries . . . . 7
Accuracy specifications on gases . . . . . . . . . . . . . . 8
Zero stabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Sensor specifications, English units . . . . . . . . . . . 10
Sensor specifications, metric units . . . . . . . . . . . . 11

Micro Motion flowmeters consist of Coriolis sensors


and microprocessor-based transmitters that provide
mass flow measurement of liquids, gases, and
slurries simply and directly.
Working together, Micro Motion sensors and
transmitters provide mass flow, volume flow, density,
and temperature measurement, all in real-time,
without the need for additional equipment. Eight
sensor product lines and six transmitter models
provide a wide variety of functionality and features to
suit your needs. For comparison between product
lines, this document provides brief specifications for
all Micro Motion sensors and transmitters. Complete
specifications for each product line are available
separately, in Product Data Sheets. Contact us or
visit our Web site at www.micromotion.com.
While providing exceptional accuracy and
repeatability, Micro Motion sensors have a low
life-time cost of ownership. With no special mounting
requirements, no moving parts to wear, and no
straight pipe run or flow conditioning requirements,
our sensors offer you a host of benefits with little to
no maintenance.
Micro Motions extensive offering of transmitters
includes those with MVD Technology, models for
installation in explosion-proof areas, and models that
can be integrally mounted to sensors. Micro Motion
transmitters also support HART , Modbus ,
FOUNDATION fieldbus, and Profibus communications
protocols.
Micro Motion is known worldwide for increasing plant
efficiency, production, and profitability. More than
300,000 Micro Motion meters are installed and
working in processes just like yours. Contact us, and
discover the best precision flowmeters available
today Micro Motion Coriolis flowmeters.

Micro Motion Flowmeters Specifications Summary

Sensors overview
All Micro Motion sensors share these features:
No moving parts

Direct measurement of mass flow rate

No special mounting or flow conditioning

Available with MVD Technology

No straight pipe run requirements

ELITE
Highest performance and rangeability
Unsurpassed immunity to field effects such as pressure, temperature, and vibration
Secondary pressure containment is standard
Models: CMF010, CMF010P, CMF025, CMF050, CMF100, CMF200, CMF300, CMF300A, CMF400

T-Series
Single-straight-tube design

Clean or sterilize in place (CIP/SIP)

Most compact
Self-draining

Secondary pressure containment to 50


bar is standard

Approved for use in 3A and EHEDG


sanitary applications

Optional integrally mounted electronics


and display
Models: T025, T050, T075, T100, T150

R-Series

F-Series
More accurate and often more costeffective than volumetric
technologies
Optional integrally mounted
electronics and local display
Models: F025, F050, F100, F200

Model D

General purpose Coriolis


flowmeter priced
competitively with traditional
flowmetering technologies
Integrally mounted sensor and transmitter, with optional
local display

improved surface finish option for sanitary


applications (3A and EHEDG approved)
Models: R025, R025F, R050, R050F, R100, R100F, R200,
R200F

Wide range of sizes, including the D600,


which is suitable for 6-inch (150 mm) line
sizes
Available with Tantalum and Tefzel wetted
parts

Model DT

High-pressure (DH) models

Operating temperatures up to
800F (426C)

Models: DH25, DH38, DH100, D150, DH150,


D300, DH300, D600

Sizes from to 1- inch (15 to


40 mm)

CNG Sensor
Designed to meet Compressed Natural Gas industry
standards
For use in automobile or light and heavy duty vehicle
dispenser design
NTEP approved
See Product Data Sheet for more details

Models: DT65, DT100, DT150

Model DL
Continuous-single-tube design
Approved for use in 3A sanitary
applications
Self draining
Models: DL65, DL100, DL200

Models: CNG050

Micro Motion Flowmeters Specifications Summary

Transmitters overview

Series 1000

Series 2000

Features MVD Technology and


diagnostics

Features MVD Technology and enhanced


diagnostics

Single variable mass or volume flowmeter

Multivariable measurement of mass flow,


volume flow, density, and temperature

One frequency and one milliamp output,


plus HART and Modbus, or intrinsically safe
frequency and milliamp outputs with HART
Easy to operate display/interface standard
Outputs rate and total
Model 1700

Output options include frequency, milliamp,


discrete in, discrete out, HART, Modbus,
FOUNDATION fieldbus H1, or Profibus-PA;
intrinsically safe outputs with one frequency
and two milliamp outputs also available
Field-mount, explosion-proof housing
Standard display/interface with programming
capabilities
Enhances sensor performance
Model 2700

Series 3000
Transmitter and discrete control functions in a single instrument
Mass or volume flow, density and temperature indication
Six outputs can be configured for the application
Field-, panel-, and rack-mount versions
Intuitive user interface
Models: 3300, 3350, 3500, 3700

RFT9739
Mass or volume flow, density and temperature indication
Four outputs can be configured for the application
Field- and rack-mount versions
Optional local display

IFT9701/IFT9703
Mass or volume flow indication
Two outputs can be configured for the application
Weathertight housing can be integrally mounted to Micro Motion F-Series and
R-Series sensors
Optional local display

Micro Motion Flowmeters Specifications Summary

Sensor features comparison

ELITE

T-Series

F-Series

R-Series

Straight-tube

Integral transmitter

Self draining

Case options
Purge fittings

Rupture disk

Applications
Liquids and slurries

Model DT Model DL








Sanitary (CIP/SIP)
High temperature

High pressure

Process fittings
Wafer





ANSI

DIN

JIS

Union

Sanitary

Wetted parts
316L stainless steel




Nickel alloy

CNG

316L/Tefzel lining

Tantalum


Titanium ASTM Grade 9


304 stainless steel
 All models

CNG050

Gas

Model D

 Optional/some models only

Micro Motion Flowmeters Specifications Summary

Transmitter features comparison


Series 1000
Inputs

Series 2000

Series 3000

IFT9701/03

Intrinsically safe sensor Intrinsically safe sensor Intrinsically safe sensor Intrinsically safe sensor Intrinsically safe sensor
4-wire input
4-wire input
9-wire input
9-wire input
9-wire input

Outputs
4-20 milliamp
Frequency/pulse

020 kHz

External zero

Two discrete,
momentary inputs

One 025 mA pressure


input

One
active or passive

One or two
active

Two

Two

One

One active
010,000 Hz

One or two active or


passive, 010,000 Hz

One active
010,000 Hz

One active
010,000 Hz

One passive
07200 Hz

Discrete

one or two discrete Three, active or passive


outputs, one discrete
input

Digital

One, active

Bell 202 and RS-485


(RS-485 only with
non_IS models)

Bell 202 and RS-485


(RS-485 only with
non_IS models), or
FOUNDATION fieldbus
H1, or Profibus-PA

RS-485

Bell 202 and


RS-485

Process "event" indication

Integrated display/interface

Communications
HART protocol

Modbus protocol
OUNDATION

Bell 202

fieldbus H1

Profibus-PA

ProLink software
AMS software

PlantWeb compatible

(1)

(1)

Specialty applications
Custody transfer

Discrete batch control

Net oil


API

Concentration

Housing options
Rack-mount

Panel-mount
Field-mount

NEMA 4X (IP65)

Explosion-proof C1D1

CENELEC Zone 1

Integral mount

 All models

RFT9739

 Optional/some models only

(1)




Requires ProLink II

Micro Motion Flowmeters Specifications Summary




Accuracy specifications on liquids and slurries


Density accuracy
Flow rate and
temperature
accuracy(1)
Series 1000
ELITE

RFT9739

IFT9701/03

Density:
0.0005 g/cc
0.5 kg/m3
CMF010P:
0.002 g/cc
2.0 kg/m3

Density:
0.0005 g/cc
0.5 kg/m3
CMF010P:
0.002 g/cc
2.0 kg/m3

Density:
0.0005 g/cc
0.5 kg/m3
CMF010P:
0.002 g/cc
2.0 kg/m3

Density:
0.002 g/cc
2.0 kg/m3
CMF010P:
0.008 g/cc
8.0 kg/m3

Density:
0.002 g/cc
2.0 kg/m3

Density:
0.002 g/cc
2.0 kg/m3

Density:(2)
0.002 g/cc
2.0 kg/m3

Not
compatible

Not
compatible

Density:
0.002 g/cc
2.0 kg/m3

Density:
0.002 g/cc
2.0 kg/m3

Density:
0.002 g/cc
2.0 kg/m3

Density:
0.002 g/cc
2.0 kg/m3

Density:
0.002 g/cc
2.0 kg/m3

Flow:
0.5%
Temperature:
1C

Flow only

Flow only

Not
compatible

Not
compatible

Flow only

Model D

Density,
DH100, DH150:
0.002 g/cc
2.0 kg/m3
DH25, DH38:
0.004 g/cc
4.0 kg/m3
D150, DH300:
0.001 g/cc
1.0 kg/m3
D300:
0.0005 g/cc
0.5 kg/m3
D600:
Not compatible

Density,
DH100, DH150:
0.002 g/cc
2.0 kg/m3
DH25, DH38:
0.004 g/cc
4.0 kg/m3
D150, DH300:
0.001 g/cc
1.0 kg/m3
D300:
0.0005 g/cc
0.5 kg/m3
D600:
Not compatible

Density,
DH100, DH150:
0.002 g/cc
2.0 kg/m3
DH25, DH38:
0.004 g/cc
4.0 kg/m3
D150, DH300:
0.001 g/cc
1.0 kg/m3
D300, D600:
0.0005 g/cc
0.5 kg/m3

Density,
DH100, DH150:
0.002 g/cc
2.0 kg/m3
DH25, DH38:
0.004 g/cc
4.0 kg/m3
D150, DH300:
0.001 g/cc
1.0 kg/m3
D300, D600:
0.0005 g/cc
0.5 kg/m3

Density:
0.002 g/cc
2.0 kg/m3
DH25, DH38:
0.004 g/cc
4.0 kg/m3
D600:
Not compatible

Flow:
0.15%
Temperature:
1C

Density:
0.001 g/cc
1.0 kg/m3

Density:
0.001 g/cc
1.0 kg/m3

Density:
0.001 g/cc
1.0 kg/m3

Density:
0.001 g/cc
1.0 kg/m3

Not
compatible

Model DL

Density,
DL65:
0.001 g/cc
1.0 kg/m3
DL100, DL200:
0.0005 g/cc
0.5 kg/m3

Density,
DL65:
0.001 g/cc
1.0 kg/m3
DL100, DL200:
0.0005 g/cc
0.5 kg/m3

Density,
DL65:
0.001 g/cc
1.0 kg/m3
DL100, DL200:
0.0005 g/cc
0.5 kg/m3

Density,
DL65:
0.001 g/cc
1.0 kg/m3
DL100, DL200:
0.0005 g/cc
0.5 kg/m3

Density:
0.002 g/cc
2.0 kg/m3

T-Series
Flow:
0.15%
Temperature:
1C

F-Series
Flow:
0.20%
Temperature:
1C

R-Series

Flow:
0.15%
Temperature:
1C

Model DT

Flow:
0.15%
Temperature:
1C

(2)

Series 3000

Density:
0.0005 g/cc
0.5 kg/m3
CMF010P:
0.002 g/cc
2.0 kg/m3

Flow:
0.10%
Temperature:
1C

(1)

Series 2000

Flow rate accuracies are base percentages. For Total Accuracy see the box on page 8. Accuracy includes the combined
effects of repeatability, linearity, and hysteresis. Specifications for liquids are based on reference conditions of water at 68
to 77F (20 to 25C) and 15 to 30 psig (1 to 2 bar).
Available with T075, T100, T150.

Micro Motion Flowmeters Specifications Summary

Accuracy specifications
on gases1
Total Accuracy1

ELITE
Flow:
with Series 1000/2000 transmitter: 0.35%
with all other transmitters: 0.50%
Temperature:
1C

For flowmeters with Series 1000 and 2000 transmitters:


If flow rate is . . .

T-Series
Not rated for gas

F-Series
Flow:
with Series 1000/2000 transmitter: 0.50%
with all other transmitters: 0.70%
Temperature:
1C

R-Series
Flow,
R025, R025F, R050, R050F, R100, R100F:
with Series 1000/2000 transmitter: 0.75%
with all other transmitters: 1.0%
R200, R200F:
Not rated for gas
Temperature:
1C

Total Accuracy =

> zero stability / (base accuracy% /


100)

base accuracy% of rate

< zero stability / (base accuracy% /


100)

[(zero stability / flow rate)


100]% of rate

For all other flowmeters:


Total Accuracy =
base accuracy% + [(zero stability / flow rate) 100]% of rate

(1)

For zero stabilities, see page 9.

Model D
Flow,
DH25, DH38:
0.50%
D150:
0.65%
D300, DH300:
Not rated for gas
Temperature:
1C

Model DT
Flow:
0.65%
Temperature:
1C

Model DL
Flow:
0.65%
DL100, DL200:
Not rated for gas
Temperature:
1C

(1)

Flow accuracies are base percentages. For total accuracy, see the box on this page. Accuracy includes the combined effects
of repeatability, linearity, and hysteresis.

Micro Motion Flowmeters Specifications Summary

Zero stabilities
Sensor
model

lb/min

English units
scfm(2)
gal/min(1)

ELITE

CMF010
CMF010P
CMF025
CMF050
CMF100
CMF200
CMF300
CMF300A
CMF400

0.000075
0.00015
0.001
0.006
0.025
0.08
0.25
0.25
1.50

0.000009
0.000018
0.00012
0.00072
0.00300
0.00959
0.02998
0.02998
0.17985

T-Series

T025
T050
T075
T100
T150

0.004
0.022
0.080
0.176
0.512

0.00048
0.00264
0.00960
0.00211
0.06146

F-Series

F025
F050
F100
F200

0.0065
0.020
0.080
0.256

0.0008
0.002
0.010
0.031

0.0864
0.2660
1.0638
3.4043

0.1765
0.544
2.177
6.965

0.1765
0.544
2.177
6.965

0.1753
0.5402
2.1619
6.9166

R-Series

R025, R025F
R050, R050F
R100, R100F
R200, R200F

0.01
0.03
0.12
0.32

0.0018
0.0054
0.0216
0.0576

0.1330
0.3989
1.5957

0.27
0.82
3.27
8.71

0.27
0.82
3.27
8.71

0.2681
0.8143
3.2473

D150
D300
D600
DH25
DH38
DH100
DH150
DH300

0.30
0.70
2.5
0.006
0.025
0.30
1.2
4.0

0.036
0.084
0.300
0.0007
0.003
0.036
0.144
0.48

3.950

32.895
0.0789
0.3289
3.947
15.789

9.0
19.2
66.0
0.18
0.68
9.0
32.6
108.0

9.0
19.2
66.0
0.18
0.68
9.0
32.6
108.0

Model DT

DT65
DT100
DT150

0.03
0.08
0.14

0.004
0.01
0.0168

0.395
1.053
1.842

0.84
2.16
3.84

0.84
2.16
3.84

0.65
1.67
2.97

Model DL

DL65
DL100
DL200

0.025
0.08
0.35

0.003
0.01
0.042

0.3289

0.66
2.16
9.6

0.66
2.16
9.6

0.51

Model D

(1)
(2)
(3)

0.0010
0.0020
0.0131
0.0784
0.3265
1.0449
3.2652
3.2652
19.48

kg/hr

Metric units
l/hr(1)
Nm3/hr(3)

0.002
0.004
0.027
0.163
0.680
2.18
6.80
6.80
40.91

0.002
0.004
0.027
0.163
0.680
2.18
6.80
6.80
40.91

0.11
0.61
2.24
4.80
13.92

0.11
0.61
2.24
4.80
13.92

0.0015
0.003
0.021
0.126
0.526
1.690
5.260
5.260
31.64

6.96

51.04
0.139
0.525
6.96
25.2

For reference conditions, see page 7, note (1).


Reference conditions for standard volume are air at 60F and 14.73 psia.
Reference conditions for normal volume are air at 0C and 1.013 bara.

Micro Motion Flowmeters Specifications Summary

Sensor specifications, English units


Sensor
model
ELITE

T-Series

F-Series

R-Series

Model D

Model DT

Model DL

(1)

(2)
(3)
(4)
(5)
(6)
(7)

CMF010P
CMF010
CMF025
CMF050
CMF100
CMF200
CMF300
CMF300A
CMF400

Line size,
inch

18

to
to
to
to 1
1 to 2
2 to 3
3 to 4
3 to 4
4 to 6
18

Maximum flow rate


gal/
lb/min
min
scfm(3)
4
4
80
250
1000
3200
10,000
10,000
20,000

0.4
0.4
10
30
120
385
1200
1200
2400

30
30
390
1000
4400
13,400
44,000
44,000
110,000

T025
T050
T075
T100
T150

to 1
1 to 1
1 to 2

25
140
500
1100
3200

3
17
60
132
384

F025
F050
F100
F200

to
to 1
1 to 2
2 to 3

80
250
1000
3200

9.6
30
120
384

Nominal flow
range, 0 to ___(1)
gal/
lb/min
min
3
3
40
125
500
1600
5000
5000
15,000

0.4
0.4
5
15
60
192
600
600
1800

25
140
500
1100
3200

3
17
60
132
384

390
1000
4400
13,400

40
125
500
1600

4.8
15
60
192
6
4.5
18
11
72
49
192
141
168
840
3000
3
3
48
168
840

Temperature
range, F(2)
400 to 400(4)

Flow tube
pressure
rating, psi
6000
Stainless steel
models: 1450

400 to 400

(4)

Nickel alloy
models: 2160

32 to 650
40 to 400(5)

1159 at 650F
1450

60 to 300(4)

1450

400 to 300(4)

1450

40 to 300(6)

1450

R025
R025F
R050
R050F
R100
R100F
R200
R200F
D150
D300
D600
DH25
DH38
DH100
DH150
DH300

to
to
to 1
to 1
1 to 2
1 to 2
2 to 3
2 to 3
1 to 1
1 to 3
3 to 6
18 to
18 to
to 1
1 to 1
1 to 3

100
76
300
180
1200
820
3200
2350
2800
7000
25,000
25
50
800
2800
7000

12
9
36
22
144
98
384
282
336
840
3000
3
6
96
336
840

390
300
1000
600
4400
3000

10,450

200,000
160
220
3200
10,450

50
38
150
90
600
410
1600
1175
1400
7000
25,000
25
25
400
1400
7000

DT65
DT100
DT150

to
to 1
1 to 1

300
800
1400

36
96
168

1225
3000
9900

150
400
700

20
48
84

32 to 800

DL65
DL100
DL200

to
to 1
1 to 2

250
800
3500

30
96
420

1000

125
500
2500

15
60
300

400 to 350
400 to 350
400 to 400

400 to 400(7)
400 to 350

400 to 400

1500
740
625
4000
5200
5600
5400
4000
900 at 800F
900 at 800F
600 at 800F
1500
900
740

The upper limit of the nominal flow range is the flow rate at which water at reference conditions causes approximately 15 psi (1 bar)
of pressure drop. For reference conditions, see page 7, note (1).
Temperature rating may be affected by hazardous area classification. Please consult.
Maximum standard volumetric flow rate is calculated based on air at 60F and 1000 psig, with a maximum pressure drop of 50 psi.
For all sensors with integral core processor or transmitter the temperature range is -60 to 257F.
For CMF400 sensors with integral booster amplifier, the temperature range is -40 to 140F.
For sensors with integral core processor or transmitter, the temperature range is -40 to 257F.
D150 and D300 sensors with Tefzel lining have a temperature range of 32 to 250F.

10

Micro Motion Flowmeters Specifications Summary

Sensor specifications, metric units


Maximum flow rate(1)

ELITE

T-Series

F-Series

R-Series

Model D

Model DT

Model DL

(1)
(2)

(3)
(4)
(5)
(6)
(7)
(8)

Nominal flow
range, 0 to__
kg/hr or l/hr(2)

Sensor
model

Line size,
mm

kg/hr or l/hr

CMF010P
CMF010
CMF025
CMF050
CMF100
CMF200
CMF300
CMF300A
CMF400

3 to 6
3 to 6
6 to 12
12 to 25
25 to 50
50 to 80
80 to 100
80 to 100
100 to 150

108
108
2180
6800
27,200
87,100
272,160
272,160
545,500

T025
T050
T075
T100
T150

10
12
12 to 25
25 to 40
40 to 50

680
3800
14,000
30,000
87,000

680
3800
14,000
30,000
87,000

F025
F050
F100
F200

6 to 12
12 to 25
25 to 50
50 to 80

2180
6800
27,200
87,270

663
1699
7476
22,767

1090
3400
13,600
43,550

R025
R025F
R050
R050F
R100
R100F
R200
R200F
D150
D300
D600
DH25
DH38
DH100
DH150
DH300

6 to 12
6 to 12
12 to 25
12 to 25
25 to 50
25 to 50
50 to 75
50 to 75
25 to 40
40 to 80
80 to 150
3 to 6
3 to 6
12 to 25
25 to 40
40 to 80

2720
2068
8160
4900
32,650
22,320
87,100
63,960
76,200
190,500
680,400
680
1360
21,780
76,200
190,500

663
510
1699
1020
7476
5100

15,150

339,802
250
350
4550
15,550

1360
1034
4080
2450
16,325
11,160
43,550
31,980
38,100
190,500
680,400
680
680
10,890
38,100
190,500

DT65
DT100
DT150

3 to 6
6 to 12
25 to 40

8160
21,780
38,100

1800
4500
15,150

4080
10,890
19,500

0 to 426

DL65
DL100
DL200

6 to 12
12 to 25
25 to 50

6780
21,780
92,250

1800

3400
13,600
68,040

240 to 177
240 to 177
240 to 204

Nm3/hr(4)
50
50
630
1615
7100
21,630
71,000
71,000
175,000

82
82
1090
3400
13,600
43,550
136,080
136,080
409,000

Temperature
range, C(3)

Flow tube
pressure
rating, bar

240 to 204(5)

240 to 204(5)

413
Stainless steel
models: 100
Nickel alloy
models: 148

0 to 343
40 to 200(6)

80 at 343C
100

50 to 150(5)

100

240 to 150(7)

100

40 to 150(7)

100

103
51
43
276
358
386
372
276

240 to 204

240 to 177
240 to 204(8)

62 at 426C
62 at 426C
41 at 426C
103
62
51

For reference conditions, see page 7, note (1) (liquids) and page 9, note (3).
The upper limit of the maximum flow range is the flow rate at which water at reference conditions causes approximately 15 psi (1
bar) of pressure drop. For reference conditions, see page 7, note (1).
Temperature rating may be affected by hazardous area classification. Please consult.
Maximum normal volumetric flow rate is calculated based on air at 15.5C and 70 bar, with a maximum pressure loss of 3 bar.
For all sensors with integral core processor, the temperature range is -50 to 125C.
For CMF400 sensors with integral booster amplifier, the temperature range is -40 to 60C.
For sensors with integral core processor or transmitter, the temperature range is -40 to 125C.
D150 and D300 sensors with Tefzel lining have a temperature range of 0 to 121C.

Micro Motion Flowmeters Specifications Summary

11

Compatibility, features, and specifications may not apply to all models. See individual sensor and transmitter data sheets for additional specifications. Due to
Micro Motions commitment to continuous improvement of our products, all specifications are subject to change without notice. Micro Motion, ELITE, and MVD are
registered trademarks of Micro Motion, Inc., Boulder, Colorado. PlantWeb is a registered trademark and Fisher-Rosemount and Delta V are trademarks of FisherRosemount, Clayton, Missouri. HART is a registered trademark of the HART Communication Foundation, Austin, Texas. Modbus is a registered trademark of
Schneider Automation, Inc., North Andover, Massachusetts. FOUNDATION is a trademark of the Fieldbus Foundation, Austin, Texas. Tefzel is a registered trademark
of E.I. Du Pont de Nemours Co., Inc., Wilmington, Delaware.

For the latest Micro Motion product specifications, view the


PRODUCTS section of our Web site at www.micromotion.com

Micro Motion Europe


Wiltonstraat 30
3905 KW Veenendaal
The Netherlands
Tel +31 (0) 318 549 549
Fax +31 (0) 318 549 559

Micro Motion Asia


1 Pandan Crescent
Singapore 128461
Republic of Singapore
Tel (65) 777-8211
Fax (65) 770-8003

Micro Motion Inc. USA


Worldwide Headquarters
7070 Winchester Circle
Boulder, Colorado 80301
Tel (303) 530-8400
(800) 522-6277
Fax (303) 530-8459

Micro Motion Japan


Shinagawa NF Bldg. 5F
1-2-5, Higashi Shinagawa
Shinagawa-ku
Tokyo 140-0002 Japan
Tel (81) 3 5769-6803
Fax (81) 3 5769-6843

2002, Micro Motion, Inc.


All rights reserved
PS-00232 (4/02)