Sunteți pe pagina 1din 2

TIMERS, RELAYS AND DISPLAYING DEVICES

Industrial relays

Industrial Relays and Bases


Devices intended for construction of automation and signalling boards. They are mainly used for command
transfer towards the executive mechanisms. Currents of comparatively heavy values enabling the direct control
of industrial executive mechanisms are commuted in comparatively small sizes. The contact surfaces are made
from silver-coated electrolytic copper. The entire contact system is closed within a lid of colourless fire-proof
plastic with a test-button installed to it. The base provides a safe electric connection of the conductors of the
electric installation and the relays and is used to install the relay to the DIN busbar.

Voltage of the
coil (V)

Socket type

ELM - 14FC
ELM - 14FC
ELM - 14FC

12 VDC
24 VDC
48 VDC

ELM-RT624-B
ELM-RT624-B
ELM-RT624-B

Relay type

Voltage of the
coil (V)

Socket type

ELM - 60.2
ELM - 60.2
ELM - 60.2
ELM - 60.2
ELM-60.2
ELM - 60.13
ELM - 60.13
ELM - 60.13
ELM - 60.13
ELM - 60.13
ELM-60.13

12 VDC
24 VDC
48 VDC
230 VAC
24VAC
12 VDC
24 VDC
48 VDC
110 VAC
230 VAC
24VAC

ELM - 90.22
ELM - 90.22
ELM - 90.22
ELM - 90.22
ELM-90.22
ELM - 90.23
ELM - 90.23
ELM - 90.23
ELM - 90.23
ELM - 90.23
ELM90.23

Relay type

Voltage of the
coil (V)

Socket type

ELM - 55.02
ELM - 55.02
ELM - 55.02
ELM - 55.02
ELM55.02
ELM - 55.04
ELM - 55.04
ELM - 55.04
ELM - 55.04
ELM - 55.04
ELM-55.04

12 VDC
24 VDC
48 VDC
230 VAC
24VAC
12 VDC
24 VDC
48 VDC
110 VAC
230 VAC
24VAC

ELM - RT702-B
ELM - RT702-B
ELM - RT702-B
ELM - RT702-B
ELM - RT702-B
ELM-RT704-B
ELM-RT704-B
ELM-RT704-B
ELM-RT704-B
ELM-RT704-B
ELM-RT704-B

Socket type

ELM - RT624-B
ELM - RT702-B
ELM - RT704-B
ELM - 90.22
ELM - 90.23

Resistance of the Number of


coil ( )
contacts

260
1080
4260

NO+NC
NO+NC
NO+NC

Resistance of the Number of


coil ( )
contacts

96
384
1540
7400
96
384
1540
1700
7400

2NO+2NC
2NO+2NC
2NO+2NC
2NO+2NC
2NO+2NC
3NO+3NC
3NO+3NC
3NO+3NC
3NO+3NC
3NO+3NC
3NO-3NC

Resistance of the Number of


coil ( )
contacts

42
168
675
14000
42
168
675
3500
14000

2NO+2NC
2NO+2NC
2NO+2NC
2NO+2NC
2NO+2NC
4NO+4NC
4NO+4NC
4NO+4NC
4NO+4NC
4NO+4NC
4NO+4NC

Packing/Box
(pcs)

Catalogue
number

100 / 1000
100 / 1000
100 / 1000

57141
57142
57143

Packing/Box
(pcs)

Catalogue
number

20 / 300
20 / 300
20 / 300
20 / 300
20 / 300
20 / 300
20 / 300
20 / 300
20 / 300
20 / 300
20/300

57601
57602
57603
57605
57606
57611
57612
57613
57614
57615
57616

Packing/Box
(pcs)

Catalogue
number

50 / 500
50 / 500
50 / 500
50 / 500
50/500
50 / 500
50 / 500
50 / 500
50 / 500
50 / 500
50/500

57521
57522
57523
57525
57526
57541
57542
57543
57544
57545
57546

Dimensions (mm)

Number of terminals
(pcs.)

Packing/Box (pcs)

Catalogue number

76 x 15
76 x 27
76 x 27
68 x 38
68 x 38

5
11
14
8
11

20 / 600
10 / 240
10 / 240
10 / 400
10 / 400

57901
57902
57912
57904
57905

TIMERS, RELAYS AND DISPLAYING DEVICES

Relay type

93

Industrial relays

Documents corresponding to
the product: EN 60947-5-1;
EN 61810

Technical Characteristics:
Supply voltage: from 12 to 230V , 50 z and from 12 to 110V DC
Acceptable deviation of the supply voltage: 85 -110% Un
Rated current of the sockets: 10
Electrical endurance: 1 000 000 cycles
Isolation resistance: 500 m /min (500V)
Impulse tension resistance: 2000V, 50z
Dielectric strength: 1000V /1 min
Turn-out time: 25ms
Working temperature: -5 - + 65
Humidity: 35 - 85% RH
Method of installation:
on a DIN rail by means of a socket

TIMERS, RELAYS AND DISPLAYING DEVICES


Industrial relays

Industrial Solid State Relays (SSR)


Industrial SSR are intended for mounting in power and control cabinets as an output switch devices with reliable ON/
OFF performance. The SSR are based on the CMOS technology. The non-contact electronic switch is optically separated
from the input signal by a photoelectric coupler. This allows use of switch currents of up to 50A despite of the devices
small overall size. Another important feature of the relay is that output load can be regulated depending on the input
signal value. The relay is mainly used to transmit control signals to actuating mechanisms since it can work at comparatively high currents making it possible to directly control actuators. SSR have transparent plastic covers to additionally
improve their safety level. The SSR use is connected with considerable heat emissions, so measures must be taken to
dispense the excessive thermal energy in the atmosphere. This is achieved through application of specially deigned
radiators. The correct definition of radiator parameters is of critical importance. It is made by calculating the heat generation capacity with the formula: Heat generation = active load current x 3.0 W/A. The heat removal surface is estimated
with the help of the following graphic:

TIMERS, RELAYS AND DISPLAYING DEVICES

Documents corresponding to
the product: EN 60947-5-1;
EN 61810

Industrial relays

94

Technical Specifications:
Load/output voltage: 30/400V 50 Hz or the solid state voltage
regulators
Rated output current: from 10 to 60
Insulating voltage: 1000 M /min (500V)
Impulse voltage stability: 2000V, 50Hz
Dielectric Strength: < 2500VAC / 1 min
Leakage current: <2mA
Turn-on time: <10ms
Operating temperature: -5 + 65
Relative Humidity: 35 - 85%RH
Type

Relay Type

ZG3NC - 2 - 10B
ZG3NC - 2 - 20B
ZG3NC - 2 - 25B
ZG3NC - 2 - 40B
ZG3NC - 2 - 60B
ZG3NC - 3 -10B
ZG3NC - 3 - 20B
ZG3NC - 3 - 25B
ZG3NC - 3 - 40B
ZG3NC - 3 - 60B

SSR
SSR
SSR
SSR
SSR
SSR
SSR
SSR
SSR
SSR

Control Volt- Output Volt- Number of Output Cur- Packing/Box Catalogue


age (V)
age (V)
phases rent ( )
(pcs)
number

3-32VDC
3-32VDC
3-32VDC
3-32VDC
3-32VDC
3-32VDC
3-32VDC
3-32VDC
3-32VDC
3-32VDC

Relay Type

ZG1NC - 2 - 10D
ZG1NC - 2 - 20D
ZG1NC - 2 - 25D
ZG1NC - 2 - 40D
ZG1NC - 3 -10D
ZG1NC - 3 - 20D
ZG1NC - 3 - 25D
ZG1NC - 3 - 40D

SS voltage regulator
SS voltage regulator
SS voltage regulator
SS voltage regulator
SS voltage regulator
SS voltage regulator
SS voltage regulator
SS voltage regulator
Relay Type

ZG33 - 3 - 10
ZG33 - 3 - 20
ZG33 - 3 - 25
ZG 33 - 3 - 40

SSR
SSR
SSR
SSR

1
1
1
1
1
2
2
2
2
2

10
20
25
40
60
10
20
25
40
60

10 / 100
10 / 100
10 / 100
10 / 100
10 / 100
10 / 100
10 / 100
10 / 100
10 / 100
10 / 100

57710
57720
57725
57740
57760
57713
57723
57735
57743
57763

Control Output Volt- Number of Output Cur- Packing/Box Catalogue


Voltage (V) age (V)
phases rent ( )
(pcs)
number

Type

Type

230VC
230VC
230VC
230VC
230VC
400VC
400VC
400VC
400VC
400VC

1-10VDC
1-10VDC
1-10VDC
1-10VDC
1-10VDC
1-10VDC
1-10VDC
1-10VDC

0-230VC
0-230VC
0-230VC
0-230VC
0-400VC
0-400VC
0-400VC
0-400VC

1
1
1
1
2
2
2
2

10
20
25
40
10
20
25
40

10 / 100
10 / 100
10 / 100
10 / 100
10 / 100
10 / 100
10 / 100
10 / 100

57810
57820
57825
57840
57813
57823
57835
57843

Control Volt- Output Volt- Number of Output Cur- Packing/Box Catalogue


age (V)
age (V)
phases rent ( )
(pcs)
number

3-32VDC
3-32VDC
3-32VDC
3-32VDC

400VC
400VC
400VC
400VC

3
3
3
3

10
20
25
40

1 / 30
1 / 30
1 / 30
1 / 30

57831
57832
57833
57834

Note: The relay output must be supplied with a varistor to ensure its over-voltage protection, whenever RRS is used to
control inductive loads.
Type of Radiator

Overall Dimensions
(L/W/H)

Approximate Load (A)

Packing/Box (pcs)

Catalogue
number

QW-A 50
QW-B 72
QW-B 100
QW-C 115
QW-E 50

60 x 50 x 50
72x100x50
100x100x50
115x100x50
150x88x35

15
20
25
40
75

1 / 50
1 / 50
1 / 50
1 / 50
1 / 40

57906
57907
57908
57909
57910

S-ar putea să vă placă și