Circuit breakers are automatically-operated electrical switches, designed to protect electrical circuits from damage caused by overload or short circuit. They can also be used
as devices for commutation and control of electrical circuits. They differ in the following
characteristics:
* Operating voltage: 230, 400V
* Number of poles: 1, 2, 3, 4
* Breaking curve:
- curve B breaks between 3 and 5 In, used for low voltage short circuit currents (long
circuits and generators)
- curve C breaks between 5 and 10 In, used for protection of main power supply cables
and conventional consumers
- curve D breaks between 10 and 20 In, used for protection of industrial consumers with
KLJKLQLWLDOFXUUHQWRZHOHFWULFPRWRUV
* Breaking capacity: 4.5, 6, 10kA
CIRCUIT BREAKERS
Miniature circuit breakers (MCB) C40N
[1
&[
constructive series
number of poles (1;2;3;4)
rated current
EUHDNLQJFXUYH
Documents corresponding
to the product:
Standard EN60898-1
EN 60947-2
Functions:
- protection of the electrical circuits from overload or short circuits of the outer circuit
- it can be used as a device for commutation and control of electrical circuits
- in combination with auxiliary devices it allows remote control, commutation or indication of the protected circuit
- for mounting in housing and industrial buildings
- for mounting at a distance from the transformer post from 150 to 850 m
- allows protection of consumers generating short circuit currents up to 4500 A
Technical data:
* Rated voltage: 230/400V; 50/60Hz
* Breaking capacity (cycle O-CO) in accordance with standard EN 60 898-1: 4500A
* Rated breaking capacity Ics= 75% Icu
,VRODWLQJYROWDJH9
* Electrical wear resistance (number of cycles): 4000
* Mechanical (number of cycles): 20000
* Class of current limiting:3
* IP code: IP>20
* Breaking curve:
B curve the overload and short-circuit protection is activated at 3-5 ln. Used for protection of big length cables and
power generators.
C the maximum current release breaks between 5 and 10 In; used to protect main power supply cables and conventional consumers
-RLQLQJWHUPLQDODWWXQQHOVFUHZWHUPLQDOZLWKFRPSRVLWLRQFROGO\GUDZSODWHGSODQH4$
* Plastic box not keeping the burning material nylon PA66, UV rays wear resistance
* Box permitivity strength: >18MV/m
$EQRUPDOKHDWLQJZHDUUHVLVWDQFHDQGUHRIWKHRXWHUSDUWV&V
* Maximum current release containing:
- copper coil - composition: pure copper T2 type
- resistance: from 0.6 to 180m
- welding effort: <150 000 N/mm
- bimetal plate composition: 5J158 to TB180 depending on the current
- thickness: 0.6mm (up to 40A) and 0.8mm (up to 63A)
- magnetic core composition: coldly draw-plated metal wire (1Gr18Ni9)
WKLFNQHVVWRP
- drawing effort: from 200 to 400N/mm
- contact head of the movable contact composition: silver graphite CAg(5)
- dimension 3x3x0.8 (up to 40A) and 4x4x0.8 (up to 63A)
- static contact composition: pure copper T2Y2
- composition of the contact head: silver graphite CAg(5)
* Power supply (conducting)
- power supply busbar 1P63, 3P63
- rigid conductors up to 25 mm
H[LEOHFRQGXFWRUVXSWRPP
* Tightening moment:1.33Nm
Mounting:
* vertical
* DIN-rail
* for mounting in housing or industrial environment without serious interference
DPELHQWWHPSHUDWXUH&WR&&
Type
C41N / 2A
C41N / 4A
C41N / 6A
C41N / 10A
C41N / 16A
C41N / 20A
C41N / 25A
C41N / 32A
C41N / 40A
C41N / 50A
C41N / 63A
2
4
6
10
16
20
25
32
40
50
63
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
Recommended
sections of the
condmuocutonrtsin (g/mm2)
Packing/Box (pcs)
Catalogue number
Curve C
Catalogue number
Curve B
1.0
1.0
1.0
1.5
2.5
2.5
4.0
6.0
10.0
10.0
16.0
12 / 240
12 / 240
12 / 240
12 / 240
12 / 240
12 / 240
12 / 240
12 / 240
12 / 240
12 / 240
12 / 240
41460B
41461B
41451B
41452B
41453B
41454B
41455B
41456B
41457B
41458B
41459B
17
CIRCUIT BREAKERS
Miniature circuit breakers (MCB) C40N
Type
C42N / 6A
C42N / 10A
C42N / 16A
C42N / 20A
C42N / 25A
C42N / 32A
C42N / 40A
C42N / 50A
C42N / 63A
Type
C43N / 6A
C43N / 10A
C43N / 16A
C43N / 20A
C43N / 25A
C43N / 32A
C43N / 40A
C43N / 50A
C43N / 63A
6
10
16
20
25
32
40
50
63
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
6
10
16
20
25
32
40
50
63
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
C40N, curve B
18
Recommended
sections of the
condmuocutonrtsin (g/mm2)
Packing/Box (pcs)
Catalogue number
Curve C
Catalogue number
Curve B
1.0
1.5
2.5
2.5
4.0
6.0
10.0
10.0
16.0
6 / 120
6 / 120
6 / 120
6 / 120
6 / 120
6 / 120
6 / 120
6 / 120
6 / 120
41470B
41471B
41472B
41473B
41474B
41475B
41476B
41477B
41478B
Recommended
sections of the
condmuocutonrtsin (g/mm2)
Packing/Box (pcs)
Catalogue number
Curve C
Catalogue number
Curve B
1.0
1.5
2.5
2.5
4.0
6.0
10.0
10.0
16.0
4 / 80
4 / 80
4 / 80
4 / 80
4 / 80
4 / 80
4 / 80
4 / 80
4 / 80
41541B
41542B
41543B
41544B
41545B
41546B
41547B
41548B
41549B
C40N, curve C
CIRCUIT BREAKERS
0LQLDWXUHFLUFXLWEUHDNHUV0&%1
[1
&[
constructive series
number of poles (1;2;3;4)
rated current
EUHDNLQJFXUYH
Documents corresponding to
the product:
Standard EN60898-1
72
45
35
81
50
Functions:
- protection of the electrical circuits from overload or short circuits of the outer circuit
- it can be used as a device for commutation and control of electrical circuits
- in combination with auxiliary devices it allows remote control, commutation or indication of the protected circuit
- for mounting in industrial buildings with high contamination level of the electric system
- for mounting at a distance from the transformer post from 150 to 850 m
- allows protection of consumers generating short circuit currents up to 6000 A
Technical data:
* Rated voltage: 230/400V; 50/60Hz
* Breaking capacity (cycle O-CO) in accordance with standard EN 60 898-1: 6000A
* Rated breaking capacity Ics= 75% Icu
,VRODWLQJYROWDJH9
* Electrical wear resistance (number of cycles): 8000
* Mechanical (number of cycles): 50000
* Class of current limiting:3
* IP code: IP>20
* Breaking curve:
B the maximum current release breaks between 3 and 5 In; used to protect long circuits and generators
C the maximum current release breaks between 5 and 10 In; used to protect main power supply cables and
conventional consumers
* Joining terminal: Combined screw clamp made of 1.5 cold extruded Q235-A material with additional coating
* Plastic box not keeping the burning material nylon PA66, UV rays wear resistance
Status indicator
* Box permitivity strength: >18MV/m
$EQRUPDOKHDWLQJZHDUUHVLVWDQFHDQGUHRIWKHRXWHUSDUWV&V
+HDWUHVLVWDQFHRILQWHUQDOQRQHOHFWULFDOFRPSRQHQWVV
* Maximum current release containing:
- copper coil - composition: pure copper T2 type
- resistance: from 0.6 to 180m
- welding effort: <150 000 N/mm
- bimetal plate composition: 5J158 to TB180 depending on the current
- thickness: 0.6mm (up to 40A) and 0.8mm (up to 63A)
- magnetic core composition: coldly draw-plated metal wire (1Gr18Ni9)
WKLFNQHVVWRP
- drawing effort: from 200 to 400N/mm
- contact head of the movable contact composition: silver graphite CAg(5)
- dimension 3x3x0.8 (up to 40A) and 4x4x0.8 (up to 63A)
- static contact composition: pure copper T2Y2
- composition of the contact head: silver graphite CAg(5)
* Power supply (conducting)
- power supply busbar 1P63, 3P63
- rigid conductors up to 25 mm
H[LEOHFRQGXFWRUVXSWRPP
* Tightening moment:1.33Nm
Mounting:
* vertical
* DIN-rail
* for mounting in housing or industrial environment without serious interference
DPELHQWWHPSHUDWXUH&WR&&
Type
C61N / 1A
C61N / 2A
C61N / 4A
C61N / 6A
C61N / 10A
C61N / 16A
C61N / 20A
C61N / 25A
C61N / 32A
C61N / 40A
C61N / 50A
C61N / 63A
1
2
4
6
10
16
20
25
32
40
50
63
6
6
6
6
6
6
6
6
6
6
6
6
Recommended
sections of the
Packing/Box (pcs)
condmuocutonrtsin (g/mm2)
1.0
1.0
1.0
1.0
1.5
2.5
2.5
4.0
6.0
10.0
10.0
16.0
12 / 240
12 / 240
12 / 240
12 / 240
12 / 240
12 / 240
12 / 240
12 / 240
12 / 240
12 / 240
12 / 240
12 / 240
Catalogue number
Curve C
Catalogue number
Curve B
41100N
41102N
41104N
41106N
41110N
41116N
41120N
41125N
41132N
41140N
41150N
41163N
41501N
41502N
41504N
41506N
41510N
41516N
41520N
41525N
41532N
41540N
41550N
41563N
19
CIRCUIT BREAKERS
0LQLDWXUHFLUFXLWEUHDNHUV0&%1
Type
&1
C62N / 4A
C62N / 6A
C62N / 10A
C62N / 16A
C62N / 20A
C62N / 25A
C62N / 32A
C62N / 40A
C62N / 50A
C62N / 63A
Type
C63N/2A
C63N/4A
C63N / 6A
C63N / 10A
C63N / 16A
C63N / 20A
C63N / 25A
C63N / 32A
C63N / 40A
C63N / 50A
C63N / 63A
Type
C64N / 2A
C64N / 4A
C64N / 6A
C64N / 10A
C64N / 16A
C64N / 20A
C64N / 25A
C64N / 32A
C64N / 40A
C64N / 50A
C64N / 63A
2
4
6
10
16
20
25
32
40
50
63
2
4
6
10
16
20
25
32
40
50
63
6
6
6
6
6
6
6
6
6
6
6
2
4
6
10
16
20
25
32
40
50
63
C60N, curve B
20
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Recommended
Packing/Box (pcs)
sections of the
condmuocutonrtsin (g/mm2)
1.0
1.0
1.0
1.5
2.5
2.5
4.0
6.0
10.0
10.0
16.0
6 / 120
6 / 120
6 / 120
6 / 120
6 / 120
6 / 120
6 / 120
6 / 120
6 / 120
6 / 120
6 / 120
Recommended
Packing/Box (pcs)
sections of the
condmuocutonrtsin (g/mm2)
1.0
1.0
1.0
1.5
2.5
2.5
4.0
6.0
10.0
10.0
16.0
4 / 80
4 / 80
4 / 80
4 / 80
4 / 80
4 / 80
4 / 80
4 / 80
4 / 80
4 / 80
4 / 80
Recommended
Packing/Box (pcs)
sections of the
condmuocutonrtsin (g/mm2)
1.0
1.0
1.0
1.5
2.5
2.5
4.0
6.0
10.0
10.0
16.0
3 / 60
3 / 60
3 / 60
3 / 60
3 / 60
3 / 60
3 / 60
3 / 60
3 / 60
3 / 60
3 / 60
Catalogue number
Curve C
Catalogue number
Curve B
41202N
41204N
41206N
41210N
41216N
41220N
41225N
41232N
41240N
41250N
41263N
41602N
41604N
41606N
41610N
41616N
41620N
41625N
41632N
41640N
41650N
41663N
Catalogue number
Curve C
Catalogue number
Curve B
41302N
41304N
41306N
41310N
41316N
41320N
41325N
41332N
41340N
41350N
41363N
41702N
41704N
41706N
41710N
41716N
41720N
41725N
41732N
41740N
41750N
41763N
Catalogue number
Curve C
Catalogue number
Curve B
41402N
41404N
41406N
41410N
41416N
41420N
41425N
41432N
41440N
41450N
41463N
41802N
41804N
41806N
41810N
41816N
41820N
41825N
41832N
41840N
41850N
41863N
C60N, curve C
CIRCUIT BREAKERS
Miniature circuit breakers (MCB) C100L
&[
rated current
EUHDNLQJFXUYH
Documents corresponding to
the product:
Standard EN60898-1
EN 60947-2
Functions:
- protection of the electrical circuits from overload or short circuits of the outer circuit
- it can be used as a device for commutation and control of electrical circuits
- in combination with auxiliary devices it allows remote control, commutation or indication of the protected circuit
Technical data:
* Rated voltage: 230/400V; 50/60Hz
* Breaking capacity (cycle O-CO) in accordance with standard EN 60 898-1: 10000A
* Rated breaking capacity Ics= 75% Icu
,VRODWLQJYRODWDJH9PLQDWLPSXOVHZDYHV
(OHFWULFDOZHDUUHVLVWDQFHQXPEHURIF\FOHV
0HFKDQLFDOZHDUUHVLVWDQFHQXPEHURIF\FOHV
* Class of current limiting:3
* IP code: IP>20
* Breaking curve: C
Mounting:
* vertical
* DIN-rail
* possibility for labeling
Type
Recommended
sections of the
condmuocutonrtsin (g/mm2)
Packing/Box (pcs)
Catalogue number
Curve C
C101L/6A
10
1.0
12 / 240
41101
C101L/10A
10
10
1.5
12 / 240
41103
C101L/16A
16
10
2.5
12 / 240
41105
C101L/20A
20
10
2.5
12 / 240
41107
C101L/25A
25
10
4.0
12 / 240
41108
C101L/32A
32
10
6.0
12 / 240
41109
C101L/40A
40
10
10.0
12 / 240
41111
C101L/50A
50
10
10.0
12 / 240
41112
C101L/63A
63
10
16.0
12 / 240
41113
Recommended
sections of the
condmuocutonrtsin (g/mm2)
Packing/Box (pcs)
Catalogue number
Curve C
Type
C102L/6A
10
1.0
6/120
41201
C102L/10A
10
10
1.5
6/120
41203
C102L/16A
16
10
2.5
6/120
41205
C102L/20A
20
10
2.5
6/120
41207
C102L/25A
25
10
4.0
6/120
41208
C102L/32A
32
10
6.0
6/120
41209
C102L/40A
40
10
10.0
6/120
41211
C102L/50A
50
10
10.0
6/120
41212
C102L/63A
63
10
16.0
6/120
41213
Recommended
sections of the
condmuocutonrtsin (g/mm2)
Packing/Box (pcs)
Catalogue number
Curve C
Type
C103L/6A
10
1.0
4 / 80
41301
C103L/10A
10
10
1.5
4 / 80
41303
C103L/16A
16
10
2.5
4 / 80
41305
C103L/20A
20
10
2.5
4 / 80
41307
C103L/25A
25
10
4.0
4 / 80
41308
C103L/32A
32
10
6.0
4 / 80
41309
C103L/40A
40
10
10.0
4 / 80
41311
C103L/50A
50
10
10.0
4 / 80
41312
C103L/63A
63
10
16.0
4 / 80
41313
21
CIRCUIT BREAKERS
Miniature circuit breakers (MCB) C100M
'[
rated current
EUHDNLQJFXUYH'
Documents corresponding to
the product:
Standard EN60898-1
EN 60947-2
22
Functions:
- protection of the electrical circuits from overload or short circuits of the outer circuit
- it can be used as a device for commutation and control of electrical circuits
- in combination with auxiliary devices it allows remote control, commutation or indication of the protected circuit
Technical data:
* Rated voltage: 230/400V; 50/60Hz
* Breaking capacity (cycle O-CO) in accordance with standard EN 60 898-1: 10000A
* Rated breaking capacity Ics= 75% Icu
,VRODWLQJYRODWDJH9
(OHFWULFDOZHDUUHVLVWDQFHQXPEHURIF\FOHV
0HFKDQLFDOZHDUUHVLVWDQFHQXPEHURIF\FOHV
* Class of current limiting:3
* IP code: IP>20
* Breaking curve: C,D
-RLQLQJWHUPLQDODWWXQQHOVFUHZWHUPLQDOZLWKFRPSRVLWLRQFROGO\GUDZSODWHGSODQH4$
* Plastic box not keeping the burning material nylon PA66, UV rays wear resistance
* Box permitivity strength: >18MV/m
$EQRUPDOKHDWLQJZHDUUHVLVWDQFHDQGUHRIWKHRXWHUSDUWV&V
* Maximum current release containing:
- copper coil - composition: pure copper T2 type
- resistance: from 148 to 230m
- welding effort: <400 N/
- bimetal plate composition: TB180/0.5
- thickness: 0.8mm
- magnetic core composition: coldly draw-plated metal wire (1Gr18Ni9)
WKLFNQHVVWRP
- drawing effort: 20N/mm2
- contact head of the movable contact composition: silver graphite CAg(5)
- dimension 6x6x1
- static contact composition: pure copper T2Y2
- composition of the contact head: silver graphite CAg(5)
* Power supply (conducting)
- power supply busbar
- rigid conductors up to 50
H[LEOHFRQGXFWRUVXSWR
* Tightening moment:1.33Nm
Mounting:
* vertical
* DIN-rail
* possibility for labeling
* for mounting in industrial environment
DPELHQWWHPSHUDWXUH&WR&&
Type
Number of
poles
C100M
1P
80
C100M
1P
100
C100M
1P
125
Packing/Box (pcs)
Catalogue number
Curve C
Catalogue number
Curve D
10
9 / 180
41180
41180D
10
9 / 180
41190
41190D
10
9 / 180
41195
41195D
CIRCUIT BREAKERS
Miniature circuit breakers (MCB) C100M
Type
Number of
poles
C100M
2P
80
C100M
2P
100
Type
Number of
poles
C100M
3P
80
C100M
3P
100
Type
Number of
poles
C100M
4P
80
C100M
4P
100
Packing/Box (pcs)
Catalogue number
Curve C
Catalogue number
Curve D
10
6 / 120
41280
41281
10
6 / 120
41290
41291
Packing/Box (pcs)
Catalogue number
Curve C
Catalogue number
Curve D
10
4 / 60
41380
41381
10
4 / 60
41390
41391
Packing/Box (pcs)
Catalogue number
Curve C
Catalogue number
Curve D
10
3 / 60
41480
41481
10
3 / 60
41490
41491
(C curve)
(D curve)
t(s)
t(s)
1000
1000
5000
5000
2000
2000
Thermal release
1000
1000
500
500
200
200
100
100
50
50
20
20
10
Thermal release
10
Electromagnetic
release
2
1
5
2
0.5
0.2
0.2
0.1
0.1
0.05
0.05
0.02
Electromagnetic
release
0.5
0.02
0.01
0.01
0.005
0.005
0.002
0.002
0.001
0.001
0.5
3 4 5
7 10
20 30
50 70
100
200
i/in
0.5
3 4 5
7 10
20 30
50 70
100
200
i/in
23
CIRCUIT BREAKERS
Miniature circuit breakers (MCB) C60DC series
&[
rated current
EUHDNLQJFXUYH
Documents corresponding to
the product:
Standard EN60898-1
EN 60898-2
24
Functions:
- for lowering constant current voltaic arc and use of the breaker at constant current consumer protection
- protection of the electrical circuits from overload or short circuit of the outer circuit at alternating current and
constant
current power supply circuits
- for commutation and control of electrical circuits
- in combination with auxiliary alternating current devices for remote control, commutation or indication of the
protected circuit
- for mounting in industrial buildings
- for protection of consumers generating short circuit currents to 6000 A at alternating current power supply
Technical data:
* Rated voltage: 240V; AC/DC
* Breaking capacity (cycle O -CO) in accordance with standard EN 60 898- 1: 6000A
* Rated breaking capacity Ics=75% Icu
,QVXODWLQJYROWDJH9
(OHFWULFDOZHDUUHVLVWDQFHQXPEHURIF\FOHV
0HFKDQLFDOZHDUUHVLVWDQFHQXPEHURIF\FOHV
* Class of current limiting: 3
* IP code: IP>20
* Breaking curve: C the maximum current release breaks between 5 and 10 In; used to protect power supply
cables and conventional consumers
-RLQLQJWHUPLQDODWWXQQHOVFUHZWHUPLQDOZLWKFRPSRVLWLRQFROGO\GUDZSODWHGSODQH4$
* Plastic box not keeping the burning material nylon PA66, UV rays wear resistance
* Box permitivity strength: >18MV/m
$EQRUPDOKHDWLQJZHDUUHVLVWDQFHDQGUHRIWKHRXWHUSDUWV&V
* Maximum current release containing:
- copper coil - composition: pure copper T2 type
- resistance: from 0.6 to 180m
- welding effort: <150 000 N/mm
- bimetal plate composition: 5J158 to TB180 according to the current
- thickness: 0.6mm (up to 40A) and 0.8mm (up to 63A)
- magnetic core composition: coldly draw-plated metal wire (1Gr18Ni9)
WKLFNQHVVWRP
- drawing effort: from 200 to 400N/mm
- contact head of the movable contact composition: silver graphite CAg(5)
- dimension 3x3x0.8 (up to 40A) and 4x4x0.8 (up to 63A)
- static contact composition: pure copper T2Y2
- composition of the contact head: silver graphite CAg(5)
- metal magnetic plate for lowering the constant current arc
* Conducting:
- power supply busbar 1P63
- rigid conductors up to 25 mm
H[LEOHFRQGXFWRUVXSWRPP
* Tightening moment: 1.33Nm
Mounting
* vertical
* DIN-rail
* for mounting in housing or industrial environment without serious current interference
$PELHQWWHPSHUDWXUH&WR&&
CIRCUIT BREAKERS
Miniature circuit breakers (MCB) C60DC series
Type
72
Recommended
sections of the
condmuocutonrtsin (g/mm2)
Packing/Box (pcs)
Catalogue number
Curve C
61DC / 1A
1.0
12 / 240
41164
61DC / 2A
1.0
12 / 240
41165
61DC / 4A
1.0
12 / 240
41166
61DC / 6A
1.0
12 / 240
41167
61DC / 10A
10
1.5
12 / 240
41168
61DC / 16A
16
2.5
12 / 240
41169
61DC / 20A
20
2.5
12 / 240
41170
61DC / 25A
25
4.0
12 / 240
41171
61DC / 32A
32
6.0
12 / 240
41172
61DC / 40A
40
10.0
12 / 240
41173
61DC / 50A
50
10.0
12 / 240
41174
61DC / 63A
63
16.0
12 / 240
41175
Recommended
sections of the
condmuocutonrtsin (g/mm2)
Packing/Box (pcs)
Catalogue number
Curve C
65
49
36
45
78
18
Type
62DC / 2A
1.0
6 / 120
41176
62DC / 4A
1.0
6 / 120
41177
62DC / 6A
1.0
6 / 120
41178
62DC / 10A
10
1.5
6 / 120
41179
62DC / 16A
16
2.5
6 / 120
41181
62DC / 20A
20
2.5
6 / 120
41182
62DC / 25A
25
4.0
6 / 120
41183
25
CIRCUIT BREAKERS
Miniature circuit breakers (MCB) DP1N (1P + N)
Functions:
- protection of the electrical circuits from overload or short circuit of the outer circuit
- it can be used as a device for commutation and control of electrical circuits
- it breaks simultaneously the lead and the neutral conductor as the heat protection is only at the lead conductor
Technical data:
* Rated voltage: 230V; 50/60Hz
* Breaking capacity (cycle O-CO) in accordance with standard EN 60 898-1: 4500 A
* Rated breaking capacity Ics = 50% Icu
,QVXODWLQJYROWDJH9
* IP code: IP>20
* Breaking curve: C the maximum current release breaks between 5 and 10 In; used to protect main power supply
cables and conventional consumers
Connecting:
-RLQLQJWHUPLQDODWWXQQHOVFUHZWHUPLQDO
* Power supply (conducting):
- power supply busbar DP1N
H[LEOHRUULJLGFRQGXFWRU
* Mounting: on DIN-rail
26
Recommended
sections of the
condmuocutonrtsin (g/mm2)
Packing/Box (pcs)
Catalogue number
Curve C
DP1N / 6
4.5
1.0
12 / 240
41006
DP1N / 10
10
4.5
1.5
12 / 240
41010
DP1N / 16
16
4.5
2.5
12 / 240
41016
DP1N / 20
20
4.5
2.5
12 / 240
41020
DP1N / 25
25
4.5
4.0
12 / 240
41025
DP1N / 32
32
4.5
6.0
12 / 240
41032
CIRCUIT BREAKERS
Auxiliary devices for circuit breakers
Type designation:
1FRQVWUXFWLYHVHULHV
number of poles - 1
Documents corresponding
to the product:
Standard EN60898-1
Type designation:
;FRQVWUXFWLYHVHULHV
number of poles - 1
Documents corresponding
to the product:
Standard EN60898-1
&RPELQHGYROWDJHFLUFXLWEUHDNHU1
Functions:
- when the voltage is reduced below 170V operation is initiated and the automatic switch is turned off
- when the voltage is increased above 270V operation is initiated and the automatic switch is turned off
- allows manual turning on of the switch after powering is restored
- indication of the position of the device
Technical characteristics:
* Rated voltage: 230/400V; 50/60Hz
,QVXODWLRQYROWDJH9
* Protection ratio: IP>20
Connection method:
'RXEOHFRQQHFWRUDWWXQQHOVFUHZFRQQHFWRU
* Feeding (conducting):
H[LEOHFRQGXFWRUVXSWRPP2
* Tightening moment of the screw: 1.33Nm
Mounting:
* vertical, by means of two pins attached to the rivets of the circuit-breaker, while the operating mechanism is connected to the switching off mechanism of the circuit breaker after the sealing lid is demounted
Type
Rated voltage
Type breaker
Packing/Box (pcs)
Catalogue number
ELMARK MN 2 60
230V
12 / 240
41909
Rated voltage
Type breaker
Packing/Box (pcs)
Catalogue number
ELMARK MX 60
230V
12 / 240
41902
$X[LOLDU\FRQWDFW2)
Functions:
-at circuit breaker switching off it sends a signal to the control or signalization system
-indication of the location of the auxiliary contact and the breaker
Technical data:
* Rated voltage: 230V
,VRODWLQJYROWDJH9
* Ingress protecting rating: IP>20
Connecting:
-RLQLQJWHUPLQDODWWXQQHOVFUHZWHUPLQDO
3RZHUVXSSO\FRQGXFWLQJH[LEOHFRQGXFWRUVXSWRPP
Mounting:
* vertical, clamps with two pins to breakers rivets, and the executive mechanism is joined up to the switching mechanism of the breaker after dismounting the seal cover
Type designation:
OF - constructive series
number of poles - 1
Documents corresponding
to the product:
Standard EN60898-1
Type
Rated voltage
Type breaker
Packing/Box (pcs)
Catalogue number
ELMARK OF 60
ELMARK SD100
230V
12 / 240
41901
230V
C100M
12 / 240
41905