Title page

Alcatel-Lucent
Remote Radio Head 2X40W - 900 MHz for GSM and W-CDMA | UA08.1
Technical Description
NN-20500-281
Issue 02.05 | February 2013

Alcatel-Lucent Proprietary
Use pursuant to applicable agreements

Use pursuant to applicable agreements


Legal notice
Legal notice

Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective
owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright 2013 Alcatel-Lucent. All rights reserved.
Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or copied or used by anyone outside
Alcatel-Lucent without its written authorization.
Not to be used or disclosed except in accordance with applicable agreements.

Alcatel-Lucent Proprietary
Use pursuant to applicable agreements

Contents
About this document
vii
Purpose ............................................................................................................................................................................................ vii
Reason for reissue

....................................................................................................................................................................... vii
vii

New in this release

...................................................................................................................................................................... vii
vii

Intended audience

...................................................................................................................................................................... viii
viii

Supported systems

..................................................................................................................................................................... viii
viii

How to use this document ....................................................................................................................................................... viii


viii
Prerequisites ................................................................................................................................................................................. viii
viii
Conventions used

....................................................................................................................................................................... viii
viii

Related information
Document support

........................................................................................................................................................................ ix
ix

Technical support

........................................................................................................................................................................... x
x

How to order

.................................................................................................................................................................................... x
x

How to comment
1

..................................................................................................................................................................... ix
ix

............................................................................................................................................................................ x
x

Roadmap to Distributed Base Station documentation


Overview ...................................................................................................................................................................................... 1-1
1-1
Roadmap to Distributed Base Stations documentation ............................................................................................... 1-2
1-2

Basic characteristics
Overview ...................................................................................................................................................................................... 2-1
2-1
Introduction ................................................................................................................................................................................. 2-2
2-2
Functional description ............................................................................................................................................................. 2-4
2-4
RRH external interfaces

......................................................................................................................................................... 2-7
2-7

Equipment characteristics

................................................................................................................................................... 2-10
2-10

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
iii
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

Contents
....................................................................................................................................................................................................................................

Hardware description
Overview ...................................................................................................................................................................................... 3-1
3-1
RRH 2X40-09 Hardware description

................................................................................................................................ 3-2
3-2

Node B hardware requirements for RRH support


4

...................................................................................................... 3-11
3-11

Configurations
Overview ...................................................................................................................................................................................... 4-1
4-1
Configurations ............................................................................................................................................................................ 4-2
4-2

Operating principles
Overview ...................................................................................................................................................................................... 5-1
5-1
OAM principles ......................................................................................................................................................................... 5-2
5-2

Index

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
iv
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

List of figures
1-1

Roadmap to Distributed Base Stations documentation ................................................................................ 1-3

2-1

2G-3G configuration

3-1

RRH 2X40-09 bulkhead .......................................................................................................................................... 3-2

3-2

SUMx front panel

4-1

Star configuration scheme in a full 2G network ............................................................................................. 4-3

4-2

Daisy chain scheme example in a 2G full network

4-3

Combined configurations

4-4

Topology scheme

4-5

Multi-standard configuration ................................................................................................................................. 4-6

............................................................................................................................................... 2-3

...................................................................................................................................................... 3-5
3-5

....................................................................................... 4-4

....................................................................................................................................... 4-5

....................................................................................................................................................... 4-5
4-5

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
v
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

List of figures
....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
vi
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

About this document


About this document

Purpose

The purpose of this document is to describe the Alcatel-Lucent Remote Radio Head
(RRH) that supports the following technologies:

2G (GSM)
3G (W-CDMA)

4G (LTE)

There are different variants of the RRH depending on the operational bandwidth and
depending on the transmitted power.
The RRH described here consists of two 900 MHz transmit paths of up to 40 W each path.
The document is about both 2G and 3G solutions, the 4G solution is not addressed. It is
called RRH 2X40-900.
Reason for reissue

The reissue reasons are:


Issue number

Issue date

Reason for reissue

02.05

February 2013

Standard issue

02.04

November 2012

Standard issue

02.03

September 2012

Standard issue

02.02

September 2011

Preliminary issue

02.01

June 2011

Draft issue

New in this release

New feature

FRS 117823 Support of 2.2 MHz spacing between 2G and 3G carriers


RRH 2X40-900 operates in a reduced bandwidth down to 4.2 MHz. Therefore GSM
and W-CDMA signals use the same available spectrum.

...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
vii
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

About this document


....................................................................................................................................................................................................................................

Intended audience

The audience for this document is Operations and maintenance personnel.


Supported systems

This document applies to Alcatel-Lucent W-CDMA UA08.1 system release.


How to use this document

No specific recommendation applies regarding the way readers should read this
document.
Prerequisites

None
Conventions used
Vocabulary conventions

For a list of the terms used in this document, see Alcatel-Lucent W-CDMA System Terminology, NN-20500-002.
For convenience, the terms RRH 2X40-900, RRH 2X40-09, or RRH are also used in this
publication.
It means this RRH variant:

Supports two 40 W output power modules


Operates in the 900 MHz bandwidth

The Station Unit Module supported by the RRH 2X40-09 is the SUMX 19. The
abbreviation used is the document SUMx refers to the SUMX 19.
Important! The SUMP or the SUMA is not supported by the RRH 2X40-900.
Typographical conventions

The following typographical conventions are used in this document:


Appearance

Description

Italicized text

Emphasized information

graphical user interface text

Text that is displayed in a graphical user


interface or in a hardware label.

IP reference, reference number

Related document that is referenced in the


document

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
viii
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

About this document


....................................................................................................................................................................................................................................

Related information

For information on subjects related to the content of this document, refer to the
documents listed in the following table:
Refer to this document

At this location

For more information on

Alcatel-Lucent W-CDMA
System - Terminology,
NN-20500-002

http://support.alcatel-lucent.
com.

Terms used in Alcatel-Lucent


9300 W-CDMA documents.

Alcatel-Lucent 9326 digital


2U Node B V2 - Technical
Description,
NN-20500-203

http://support.alcatel-lucent.
com.

Alcatel-Lucent 9326 digital 2U


Node B V2 :

Alcatel-Lucent 9926 Base


Band Unit Node B for
W-CDMA - Technical
Description,
NN-20500-283

http://support.alcatel-lucent.
com.

Alcatel-Lucent 9396 digital


2U Node B - Technical
Description, 401-382-964

http://support.alcatel-lucent.
com.

Basic characteristics

Hardware description

Alcatel-Lucent 9926 Base Band


Unit Node B

Basic characteristics

Hardware description

The Alcatel-Lucent 9396 digital


2U Node B :

Basic characteristics

Hardware description

Alcatel-Lucent 93xx Node B


- Commissioning and Fault
Management User Manual:
TIL, NN-20500-019

http://support.alcatel-lucent.
com.

How to perform the Node B


installation, commissioning and
maintenance tasks using the
Node B TIL (Terminal for
Local Installation) tool

Distributed BTS Technical


Description - BTS
Document Sub-System
Description, 3BK 21679
AAAA TQZZA

http://support.alcatel-lucent.
com.

The Alcatel-Lucent Distributed


BTS for GSM:

Basic characteristics

Hardware description

Document support

For support in using this or any other Alcatel-Lucent document, contact Alcatel-Lucent at
one of the following telephone numbers:

1-888-582-3688 (for the United States)


1-317-377-8618 (for all other countries)

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
ix
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

About this document


....................................................................................................................................................................................................................................

Technical support

For technical support, contact your local Alcatel-Lucent customer support team. See the
Alcatel-Lucent Support web site (http://www.alcatel-lucent.com/support/) for contact
information.
How to order

To order Alcatel-Lucent documents, contact your local sales representative or use Online
Customer Support (OLCS) (http://support.alcatel-lucent.com)
How to comment

To comment on this document, go to the Online Comment Form (http://infodoc.alcatellucent.com/comments/) or e-mail your comments to the Comments Hotline
(comments@alcatel-lucent.com).

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
x
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

1oadmap to Distributed
R
Base Station
documentation

Overview
Purpose

This chapter provides the roadmap for Distributed Base Station documentation.
Contents
Roadmap to Distributed Base Stations documentation

1-2

...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
1-1
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

Roadmap to Distributed Base Station documentation

Roadmap to Distributed Base Stations documentation

....................................................................................................................................................................................................................................

Roadmap to Distributed Base Stations documentation


The following figure shows where the current document stands within the W-CDMA
customer documentation.
For a global view of the W-CDMA customer documentation, see the Roadmap chapter in:

Alcatel-Lucent W-CDMA System - Document Collection Overview, NN-20500-050


Alcatel-Lucent W-CDMA System - Access Network Elements Overview,
NN-20500-233

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
1-2
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

Roadmap to Distributed Base Station documentation

Roadmap to Distributed Base Stations documentation

....................................................................................................................................................................................................................................

Figure 1-1 Roadmap to Distributed Base Stations documentation

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
1-3
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

Roadmap to Distributed Base Station documentation

Roadmap to Distributed Base Stations documentation

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
1-4
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

Basic characteristics
2

Overview
Purpose

This chapter provides the basic characteristics of the RRH 2X40W.


Contents
Introduction

2-2

Functional description

2-4

RRH external interfaces

2-7

Equipment characteristics

2-10

...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
2-1
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

Basic characteristics

Introduction

....................................................................................................................................................................................................................................

Introduction
Overview

The RRH is deployed in networks that support different technologies. Installing the
correct software is enough to migrate from one technology to another one.
It can also be shared by different operators (RAN sharing).
The RRH specified in this document operates in the following technologies:

Single technology
2G only (GSM)

3G only (W-CDMA)
4G only (LTE )1

Multi-technologies, using different modules for each technology:


2G/3G (GSM/W-CDMA)

2G/4G (GSM/LTE)1

3G/4G (W-CDMA/LTE ) 1

2G/3G/4G (GSM/W-CDMA/LTE) 1

Multi-technologies, using the same module for the different technologies:


2G/3G (GSM/W-CDMA)
2G/4G (GSM/LTE) 1

3G/4G (W-CDMA/LTE)1

2G/3G/4G (GSM/W-CDMA/LTE1)

Note: 1
The RRH 2X40-09 is hardware ready to the support LTE technology but the feature is
not yet implemented.
The RRH performs the transmission and reception of radio frequencies in the
corresponding frequency band. It also performs the baseband processing. It consists of
one digital-analog board and two power amplifier boards. The RRH 2X40-900 operates in
a reduced bandwidth down to 4.2 MHz, thus, GSM and W-CDMA signals use the same
available spectrum.
The RRH 2X40 supports antenna diversity.
If the 3G (or 4G) technology is used, the RRH is linked to the d2U or to the BBU through
a CPRI interface and optical fibers.
If the 2G technology is used, the RRH is connected to the BSC through a central
equipment called Station Unit Module (SUMx). This equipment is hosted either in an
existing BTS rack, or in a dedicated Site Support Cabinet (SSC). The SSC also integrates
AC/DC converters and batteries for power back-up.
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
2-2
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

Basic characteristics

Introduction

....................................................................................................................................................................................................................................

The following figure shows an example of configuration.


Figure 2-1 2G-3G configuration

In this example the RRH is configured for 2G/3G configuration.


The RRH is physically connected to both:

The SUMx through a GE interface


The CCM through a CPRI interface

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
2-3
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

Basic characteristics

Functional description

....................................................................................................................................................................................................................................

Functional description
Introduction

In transmission, the RRH:

Receives the signal coming from the CPRI or the ethernet interface.
Processes the signal.
Sents it to the radio interface.

In reception, the RRH:

Receives two RF signals from the antennas.

Processes the two RF signals.


Sends the two RF signals to the daisy chain or to the BBU.

In detail, the RRH supports the following functions:

Radio access modem

Optical access
Configuration, supervision, alarm and failure monitoring
Part of call processing

The SUMx (Station Unit Module in 19 housing) is a controller managing transmissions,


alarms, operations and maintenance tasks. It is necessary for the GSM configuration.
Radio access and modem

The radio functions are the following:

Up-sampling, frequency up-conversion, amplification, and filtering


Filtering, low noise amplification, frequency down-conversion and down-sampling

The modem functions are the following:

Channel coding, modulation, summing and filtering

Filtering, demodulation and channel decoding

The following diagram describes the functional process.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
2-4
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

Basic characteristics

Functional description

....................................................................................................................................................................................................................................

Optical access

This function provides duplex optical communication towards the Node B site through
optical fibers using Single-Mode or Multi-Mode propagation:

In Single-Mode propagation, two variants of SM SFP are available:


The Single Mode Single Fiber (SM SF), one fiber carries both downlink and
uplink signals using Coarse Wavelength Division Multiplexing (CWDM).
The Single Mode Dual Fiber (SM DF), carries the DL/UL in two separate fibers,
one fiber carries the downlink signal, and another fiber carries the uplink signal.
In Multi-Mode propagation, one fiber carries the downlink signal, and another fiber
carries the uplink signal.

Configuration/supervision

This function is in charge of configuring and supervising the modules as well as ensuring
inventory information reporting.
The remote inventory functionality allows the W-CDMA OAM access to determine the
state of the RRH.

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
2-5
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

Basic characteristics

Functional description

....................................................................................................................................................................................................................................

Call processing

The call processing function is in charge of radio resource management inside the base
station equipment. Call processing manages:

W-CDMA services as described in 3GPP standards


Internal configuration and implementation services
Channel setup and management for both common and dedicated channels

Cell management, power control, handover, and measurement processing

Station Unit Module (SUMx)

It integrates the following functions:

Transmission functions
Operations and maintenance tasks of the BTS
Remote inventory function
Clock distribution

Provision of some external interfaces and management of internal interfaces


Optional GPS board for GSM BTS releases which provides high accuracy clock and
enables a time and frequency synchronization for the BTS

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
2-6
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

Basic characteristics

RRH external interfaces

....................................................................................................................................................................................................................................

RRH external interfaces


RRH

The RRH is equipped with the following external interfaces:


Interface

Description

Power supply

Provides the mains power. The RRH is


supplied with a 48 V DC power supply.

Ground

Provides the grounding

Radio

Provides the radio interface between the RRH


and the antenna
The radio interface consists of two RF ports
for the connection to the Tx/Rx Main and Rx
Diversity antennas for one sector only.
The radio interface impedance is 50 ohm.

CPRI1

Provides optical CPRI interface to the BBU


It consists of two optical links. One for the
communication between the RRH and the
optical module of a Node B (BBU), or the
previous RRH in a daisy-chain configuration

Optical1

Provides optical Gigabyte Ethernet interface

External alarms

Two external customer alarms

AISG

The RRH is equipped with an AISG interface


which is controlled by the controller module
(CCM) of the Node B. It can be used to
connect a Tower Mounted Amplifier (TMA) or
a Remote Electrical Tilt Automatic (RETA)
unit.

Optical interfaces

There are two optical ports on the RRH: one master, one slave.
The optical mode (SM or MM) is given by the distance between the Node B and the
RRH.
The RRH master port is used in daisy chain mode to connect the second RRH.

The SFP optical transceivers are Single Mode or Dual Mode.


SFP optical transceiver Single Mode:

RRH (slave port) to SUMx: SFP 1310 nm wavelength


RRH (master port) to RRH (daisy chain): SFP 1550 nm wavelength

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
2-7
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

Basic characteristics

RRH external interfaces

....................................................................................................................................................................................................................................

SFP optical transceiver Multimode Mode:


RRH (slave port) to SUMx: SFP 850 nm wavelenght
RRH (master port) to RRH (daisy chain): SFP 850 nm wavelength

The SFP optical transceivers are equipped with LC connectors.


AISG interface

The RETA unit allows adjustment of the antenna tilt without tower climb, and depending
on configuration without site visit.
The AISG interface is used for RETA unit connection. It is also used to connect the Tower
Mounted Amplifier (TMA) when it is provided.
The AISG interface is controlled from the Node B digital unit. Control access is
performed on-site via a PC (loaded with a standard software) connected to the BBU or at
a remote location when using a remote access.
All physical and electrical specifications related to the RETA comply with the Antenna
Interface Standards Group (AISG).
SUMx

The SUMx module can be hosted in:

An existing BTS cabinet (with enough space for additional standard 19 equipment)
In a dedicated Site Support Cabinet (SSC)
The SSC integrates AC/DC converters and batteries for power backup.

In a distributed solution, the BTS (RRH 2X40W + SUMx) is connected to the BSC
through a TDM or IP transmissions.
The SUMx is connected to the RRH using three high speed optical connections.
The external interfaces are located at the front of the SUMx 19 box.
Interface

Description

Transmission interface

Abis TDM, Abis Ethernet

Radio

HSL over Ethernet to RRH

Power supply

48VDC

The SUMx 19 is offered in one power


variant: DC power mode. It is designed to
be powered from -48VDC BTS power
plant as well as from any site support
cabinet.

The acceptable variation in the input


voltage, under normal operation, is ranged
from -40.5 V to -57 V.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
2-8
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

Basic characteristics

RRH external interfaces

....................................................................................................................................................................................................................................

Interface

Description

High speed interfaces

Five high speed interfaces with SFP


connection
One high speed Ethernet link

External alarms

Eight external alarms adapted to the customer


requirements

E1 connections

Four E1 physical interfaces

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
2-9
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

Basic characteristics

Equipment characteristics

....................................................................................................................................................................................................................................

Equipment characteristics
Mechanical Data

Mechanical data for the Alcatel-Lucent RRH and the SUMx:


Parameter

RRH 2X40-09
without solar
shield

RRH 2X40-09 with


solar shield

SUMx

Height (mm)

300

300

483

Width (mm)

443

460

56

Depth (mm)

150

154

313

< 18

Weight (kg)

Environmental Data

Environmental data for the Alcatel-Lucent RRH and the SUMx


Parameter

RRH 2X40-09

SUMx

Climatic requirements

For operation: ETSI EN 300


019-1-4 / ETS 300 019-1-4
class 4.1E

ETS 300 019-2-3 (class 3.2)

Operationing temperature

-40 C to +50 C (up to


+55C with solar shield)

5 C to +65 C.

Absolute humidity

0.03 g/m 3 to 36 g/m 3 .

0.03 g/m 3 to 36 g/m 3

Cooling method

Natural convection cooling

Maximum amount of solar


radiated energy on the
external surfaces

1120 W/m 2

Acoustic noise

Noiseless

Electro Magnetic
Compatibility (EMC)

EN 300 132-2

In accordance with ISO 7779


are the following: LwAd = 56
dB(A) at 25C

EN 300 132-3
3GPP 25113

Safety

EN 60215
IEC 215
EN 60 950
IEC 950

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
2-10
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

Basic characteristics

Equipment characteristics

....................................................................................................................................................................................................................................

Electrical data

Electrical data for the Alcatel-Lucent RRH and the SUMx:


Characteristics

RRH 2X40-09

SUMx

Operating DC voltage

-48 V (-40.5 / -57)

-48 V from BTS power plant


or any site support cabinet

Power consumption

2Tx /2Rx max load 100%

30 W (fully loaded)

390 W

AISG / RET max

42 W

No battery back-up integrated

Battery back- up

RF characteristics

RF characteristics for the Alcatel-Lucent RRH:


Characteristics

RRH 2X40-09

Operating frequency band (MHz)

880-915 / 925-960

TX output power

40 W max

Carriers

Depends on RF configuration, see tables


below

Rx Sensitivity (dbm)

-112

RX diversity

Yes

The RRH output power depends on the number of carriers configured per module and the
mix of technologies running.
The following table describes the output power values in case of pure GSM and
Multi-mode configurations for the RRH 2X40-09W.
Number of GSM
carriers

GMSK output
power class 2 (W)

GMSK output
power class 2 with
moderate power
overbooking (W)

8 PSK output
power (W)

40

40

27

40

40

27

17

17

11

17

17

11

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
2-11
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

Basic characteristics

Equipment characteristics

....................................................................................................................................................................................................................................

Number of GSM
carriers

GMSK output
power class 2 (W)

GMSK output
power class 2 with
moderate power
overbooking (W)

8 PSK output
power (W)

13

15

13

15

The following table describes the output power values in case of W-CDMA configuration
or mixed configurations for the RRH 2X40-09W.
Configurations

W-CDMA output power

GSM output power

1 W-CDMA carrier and 1


GSM carrier

40 W

40 W

2 non contiguous (within


15MHz) W-CDMA carriers
and 2 GSM carriers

2 carriers at 20 W

2 carriers at 20 W

1 W-CDMA carrier and 3


GSM carriers

1 carrier 20 W

3 carriers at 13 W

2 non contiguous (within


15MHz) W-CDMA carriers
and 3 GSM carriers

2 carriers at 20 W

3 carriers at 13 W

2 non contiguous (within


15MHz) W-CDMA carriers
and 4 GSM carriers

2 carriers at 20

4 carriers at 10W

Optical and topology characteristics

Optical and topology characteristics for the Alcatel-Lucent RRH:


Type of fibres

Single-mode (SM) and Multi-mode (MM)


variant

Optical fibre length

Up to 500 m, using MM fibre


Up to 20 km, using SM fibre

RRH configuration

Star, Daisy Chain, Optical Ring


Up to 6 RRHs per fibre link

Maximum amount of solar radiated energy


on the external surfaces

1120 W/m 2

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
2-12
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

Basic characteristics

Equipment characteristics

....................................................................................................................................................................................................................................

Miscellaneous

External alarms

2 for RRH 2X40-09W

8 for SUMx

Deployment and connectivity

The RRH is easy to install. It is a plug and play module.


The pieces of equipment listed below concern the RRH variants.
The RRH main body mechanics is equipped with the following pieces of equipment:

Solar shield
The solar shield protects the RRH from solar radiation. It is factory-assembled to the
RRH main body.
Connection box (also called cable box)
The connection box protects the RRH bottom connectors from climatic conditions.
These bottom connectors are reachable through an access panel
Mounting kit
A mounting kit is required to install the RRH on a wall, a pole, or a floor.
Handle
The handle facilitates installation. This handle is factory-assembled to the RRH main
body and should be removed after installation.

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
2-13
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

Basic characteristics

Equipment characteristics

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
2-14
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

Hardware description
3

Overview
Purpose

This chapter describes:

The RRH 2X40W bulkhead hardware


The connectivity
The LED indicators
The SUMx

Contents
RRH 2X40-09 Hardware description
Node B hardware requirements for RRH support

3-2
3-11

...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
3-1
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

Hardware description

RRH 2X40-09 Hardware description

....................................................................................................................................................................................................................................

RRH 2X40-09 Hardware description


Bulkhead description

The following figure shows a view of the RRH 2X40-09 bulkhead.


Figure 3-1 RRH 2X40-09 bulkhead

Connector description

This topic gives an overview of the connectors located on the RRH bulkhead and on the
SUMx front pannel.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
3-2
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

Hardware description

RRH 2X40-09 Hardware description

....................................................................................................................................................................................................................................

The external interfaces are located at the bottom side of the RRH housing.
Interface

Connector

DC power input

For DC power connection:

Cable composed of two 6 mm cores (10


AWG), blue (48 V DC), black (0 V)

On unit side:

Tyco connector type, three pin circular


female for DC connection

Ground

Adapted ground cable

RETA

The RRH is equipped with an interface for


controlling a RET antenna.
All physical and electrical specifications of
this interface concerned are compatible with
the AISG standard.
Interface between RRH and RETA (AISG
connector):

Protocol: RS-485

Circular connector: female, eight pins,


IEC 60 130-9, IP 67

DC power specification: + 14 V DC
nominal

Antenna connections

7/16 female connectors for the connection


with the main or diversity antenna

External alarms

Circular 12 pin connector for the connection of


two external customer alarms (two external
alarm pairs)

Ethernet interface

One RJ-45 Ethernet port for local terminal


connection

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
3-3
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

Hardware description

RRH 2X40-09 Hardware description

....................................................................................................................................................................................................................................

Interface

Connector
1

Optical interfaces

Two optical ports: one master, one slave2


The SFP optical transceivers are Single Mode
(SM) or Multi Mode (MM) 3.
SFP optical transceiver SM:

RRH (slave port) to SUMx: SFP 1310 nm

RRH (master port) to RRH (daisy chain):


SFP 1550 nm

SFP optical transceiver Multi Mode (MM):

RRH (slave port) to SUMx: SFP 850 nm

RRH (master port) to RRH (daisy chain):


SFP 850 nm

The SFP optical transceivers are equipped with


LC connectors.
Notes:

1.

The optical interfaces support SFP transceivers which can be installed on field without
opening the RRH.

2.

The RRH master port is used in daisy chain mode to connect the second RRH.

3.

The optical mode (SM or MM) is given by the distance between the Node B and the RRH.

LED description

There is only one green-red bi-colored LED on the RRH. The BBU or the SUMx gets the
LED status periodically and reports it to the management system.
The following table lists the LED indicator states and the associated meaning.
LED status

RRH state

OFF

Power not applied

GREEN

Powered and RRH is transmitting

BLINKING GREEN

Powered, all OK but RF transmitting disabled

RED

Major hardware failure

YELLOW

CPRI link failure

BLINKING YELLOW

Initial power on and firmware download in


progress

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
3-4
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

Hardware description

RRH 2X40-09 Hardware description

....................................................................................................................................................................................................................................

SUMx front panel

The following figure shows a view of the SUMx front panel.


Figure 3-2 SUMx front panel

The connection is located at the left side of the subrack front panel.

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
3-5
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

Hardware description

RRH 2X40-09 Hardware description

....................................................................................................................................................................................................................................

It provides connection possibility for external interfaces as:

Power supply

Ground
E1
External alarms

This table describes the connector used for the interface located on the SUMx front panel:
Interface

Connector

Ground

Provides ground interface for the complete


subrack.

Power supply

Provides power supply interface for all


subrack components.

Transmission interface, E1 PORT 1/2

Provides 2 Abis Interfaces.


9-pin Sub-D female
The connector is pre-equipped for both 75
ohm and 120 ohm impedance cables. The
impedance is selected by the type of cable
connector used.
Two more Abis Interfaces are possible with a
piggy-back board.

HSE 1/2

RJ-45 Ethernet connector


Provides two High Speed Ethernet interfaces
for future use.

HSO1, HSO2, HSO3

SFP connector
High speed optical interfaces for Remote
Radio Head connection.

OPT1, OPT2

SFP connector
Optical interfaces for future use

BTS Connection Area

37-pin Sub-D female


Provides the following digital interfaces:

XBCB

XRT

XGPS, XGPS CLKX

CLK1

Abis relay control

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
3-6
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

Hardware description

RRH 2X40-09 Hardware description

....................................................................................................................................................................................................................................

Interface

Connector

BTS Terminal

To connect a computer terminal.


Provides V.24 asynchronous serial interface
for local maintenance and configuration
purposes
Presence of a terminal automatically detected

External alarms

Provides eight interfaces to connect eight


external alarms (adapted to the customer
requirements)

Test

9-pin Sub-D male


Provides remote access

GPS

SMB male
Provides a synchronization output from an
optional on-board GPS receiver

TRANS1

RJ-45
Provides traffic connection to the IP network

MMI-ETH

RJ-45
Used for connection with PC NEM
For local maintenance and configuration
purposes

AUX1

RJ-45
Connection for auxiliary equipment

There are eight LEDs on the SUMx front panel, which provide a visual indication of the
operational status of the SUMx module. The following table describes each LED and
defines the associated operational states.
SUMx LED description
LED

Color

P1

Yellow

P2

Yellow

Status

Description
Abis link 1 state

ON

Abis link 1
configured and ok

Blinking

Failure detected on
Abis link 1

OFF

Abis link 1 not


configured (not used)
Abis link 2 state

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
3-7
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

Hardware description

RRH 2X40-09 Hardware description

....................................................................................................................................................................................................................................

LED

P3

P4

OP

OMTr

Color

Status

Description

ON

Abis link 2
configured and ok

Blinking

Failure detected on
Abis link 2

OFF

Abis link 2 not


configured (not used)

Yellow

Abis link 3 state


ON

Abis link 3
configured and ok

Blinking

Failure detected on
Abis link 1

OFF

Abis link 3 not


configured (not used)

Yellow

Abis link 4 state


ON

Abis link 4
configured and ok

Blinking

Failure detected on
Abis link 4

OFF

Abis link 4 not


configured (not used)

Yellow

Yellow

Operational status
ON

Module in
operational status

Short blinking

Mismatch between
SW running on the
board and SW
version set by the
management system

Blinking

Transient state to
reach operational
state

Fast blinking

State of the module


unknown

OFF

Module is not in
operational status
Status of the O&M transmission link

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
3-8
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

Hardware description

RRH 2X40-09 Hardware description

....................................................................................................................................................................................................................................

LED

ON

Color

Status

Description

ON

OML connection
established

Blinking

Transient state
corresponding to the
OML connection
establishment

Fast blinking

Searching of the
OML on the Abis
(Scanning mode)

OFF

OML disconnected,
no ongoing attempt to
establish the OML
connection

Green

FAULT

Power status
ON

SUMx powered ON

OFF

SUMx powered OFF

Red

Alarm status
ON

Fatal alarm on
SUMX or on any
SBL inside the BTS

Blinking

Non fatal alarm on


SUMX or on any
SBL inside the BTS

Short blinking

OCXO warm up

OFF

No alarm

The backplane is a multi-layer PCB. It distributes the 48/ 60 V DC, to power the
subrack equipment, and the digital signals to the SUMx module.
On the rear side of the back panel there is a Ribbon Cable C 64 M (DIN 41612)
connector. It is used to interconnect the subracks and the SUMx 19poste for future
applications.
The Abis Interface is the digital interface to the BSC. The SUMx provides four G.703
Abis interfaces.
They support the following communications links:

TCH, which carries speech and/or data


OML, which uses a LAPD protocol

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
3-9
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

Hardware description

RRH 2X40-09 Hardware description

....................................................................................................................................................................................................................................

RSL, which carries signaling data for the telecommunications functions


Q1 Link, which carries transmission management data

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
3-10
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

Hardware description

Node B hardware requirements for RRH support

....................................................................................................................................................................................................................................

Node B hardware requirements for RRH support


Requirement

The following Node Bs are programmed to support RRH.


Parameter
BBU

2G
SUMX 19

3G
Most relevant d2U
versions and
modules: x and e
modules

2G/3G
Most relevant d2U
versions and
modules: x and e
modules
SUMX 19

RRH

MC-RRH 2X40-09
supporting 2G only
mode

MC-RRH 2X40-09
supporting 3G only
mode

RRH 2X40-09
supporting 2G and
3G mixed mode

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
3-11
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

Hardware description

Node B hardware requirements for RRH support

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
3-12
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

Configurations
4

Overview
Purpose

This chapter describes the configurations of the RRH 2X40W.


Contents
Configurations

4-2

...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
4-1
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

Configurations

Configurations

....................................................................................................................................................................................................................................

Configurations
Radio configurations

The RRH can be linked to the BBU, using different configurations:

Star
Daisy-chain
Sector or repeater

The RRH is used as a:

Full 2G module

Full 3G module
2G/3G module

In a full GSM configuration, the SUMx is directly connected to the RRH 2X40W with
optical Ethernet cables (max. six RRH), while in a multistandard configuration the SUMx
is connected to the W-CDMA/LTE BBU module by the optical Ethernet cable and CPRI.
Star configuration

The star configuration information involves the following hardware components:

RRH on the remote site


An optical module on the Node B site, or a SUMx board

The implementation of the RRH solution allows to connect, in star configuration, a


maximum of six RRH to a BBU, or three RRHs to a SUMx. Each RRH provides service
to a single sector, which supports either a single-cell or a twin-cell configuration,
allowing a maximum of two managed cells per RRH. As a example, a maximum of
twelve remote cells can be provisioned with six RRH in a full 3G solution.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
4-2
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

Configurations

Configurations

....................................................................................................................................................................................................................................

Figure 4-1 Star configuration scheme in a full 2G network

Daisy chain configuration

More cells can be provisioned by daisy-chaining three RRHs (or RFMs) to a single fiber
link coming from the BBU, or the SUMx.

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
4-3
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

Configurations

Configurations

....................................................................................................................................................................................................................................

Figure 4-2 Daisy chain scheme example in a 2G full network

Sector or repeater configuration

An RRH operates in one of the following modes selected from OAM:

Sector mode to use the RRH as another remote sector not configured at Node B
Repeater mode to use the RRH as a local sector configured at Node B. This allows to
extend coverage of a local sector to rural or shadow areas.

When RRHs are used as repeaters on a 20-km optical fiber length, the cell size (set at the
OMC) of the last RRH in the daisy-chain cannot exceed 5 km.
To guarantee a continuity in mobility coverage, RRH cell management is based on the
following parameters:

Optical fiber length

Cell size
Soft handover (SHO) between local and remote cells

Combined configurations

The connection scheme can also be a combination of chain and ring and star as shown in
the next figure.
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
4-4
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

Configurations

Configurations

....................................................................................................................................................................................................................................

Figure 4-3 Combined configurations

Any topology is possible, as long as there are

Less than three links to the SUMx


Less than two links to the RRH

Figure 4-4 Topology scheme

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
4-5
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

Configurations

Configurations

....................................................................................................................................................................................................................................

Multi-Standard configuration

The RRH can also be configured in a multi-technology environment as shown in the next
figure.
Figure 4-5 Multi-standard configuration

GSM
SUMx 19

HSO

RRH
2G/3G
CPRI

RRH
2G/3G
CPRI

HSO

W-CDMA
d2u v2 / BBU

RRH
2G/3G
HSO

CPRI

Multiple RRH per cell (optional)

To extend mobility coverage without adding cells to a Node B, Multiple RRH Sets (MRS)
can be used following the next rules:

An MRS contains one Cell-Mode RRH (CM RRH) acting as a normal cell, and
several Repeater-Mode RRHs (RM RRHs) acting as repeaters.
Up to four RM RRHs can be set in star or daisy-chain configuration.
Up to three MRSs can be connected to a d2U Node B in star configuration; and up to
six in daisy-chain configuration.
One MRS can support up to 12 cells and up to four carriers.
One BBU can support up to 12 RRHs.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
4-6
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

Operating principles
5

Overview
Purpose

This chapter provides the RRH 2X40 operating rules according to the configuration
modes.
Contents
OAM principles

5-2

...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
5-1
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

Operating principles

OAM principles

....................................................................................................................................................................................................................................

OAM principles
OAM mastership rules

In 2G configuration the Operation and Maintenance Center (OMC 2G) is used as


management system, while in 3G it is the Wireless Management System (WMS 3G).
When RRH is in 2G and 3G mixed mode the 2G system (OMC 2G) is the master, and
RRH acts as a virtual machine for 3G usage. Therefore some actions such as hardware
reset, software upgrade are only managed by the OMC 2G.
This table provides the OAM mastership rules:
Supervison
2G BTS

OMC 2G

NA

3G BBU

NA

WMS 3G

RRH 2G PA and TRX

OMC 2G

NA

RRH 3G PA

NA

WMS 3G

RRH 2G/3G (Rx path, TMA)

OMC 2G

WMS 3G

RRH full reset

OMC 2G

NA

RRH virtual reset (resets only


one techno)

NA

WMS 3G

Tx path

Inventory
RRH 2G inventory, including
TMA

OMC 2G

NA

RRH 3G inventory

NA

WMS 3G

2G BTS inventory including


cabinet

OMC 2G

NA

3G d2U inventory

NA

WMS 3G

Software management
RRH software
download/activation

OMC 2G

NA

RRH software version


reporting

OMC 2G

WMS 3G

RRH and 3G BBU software


compatibility reporting

NA

WMS 3G
Power management

RRH 2G PA

OMC 2G

NA

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
5-2
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

Operating principles

OAM principles

....................................................................................................................................................................................................................................

RRH 3G PA

NA

WMS 3G

Frequency management
RRH 2G PA Frequency
configuration

OMC 2G

NA

RRH 3G PA Frequency
configuration

NA

WMS 3G

External alarms management


VSWR configuration (*),
RRH Ext alarm configuration

OMC 2G

WMS 3G

2G Cabinet external alarms


configuration

OMC 2G

NA

RRH provisioning and Cabling / RRH port mapping


2G

OMC 2G

NA

3G

NA

WMS 3G
Switching mode

Switch RRH from 2G mode


to 2G+3G mode

OMC 2G

NA

Switch RRH from 2G+3G


mode to 2G

OMC 2G

NA

Switch RRH from 2G+3G


mode to 3G

OMC 2G

NA

Switch RRH from 3G mode


to 2G+3G

OMC 2G

NA

Counter support
2G

OMC 2G

NA

3G

NA

WMS 3G/NPO

RET ALD according to AISG v2.0


RET control

NA

WMS 3G
Commissioning

RRH

NEM

NA

Capacity licensing
3G capacity licensing
(frequencies/power) for 3GPA

NA

WMS 3G

2G capacity licensing

OMC 2G

NA

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
5-3
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013

Operating principles

OAM principles

....................................................................................................................................................................................................................................

(*) Note : Due to the software achitecture in 2G/3G MC-RRH, recovery actions
performed on 3G VSWR part have to be also performed on the 2G part. For more details
refer to document BTS Alarm Dictionary / BTS Document / Reference Guide Release
B11 / 3BK 21625 AAAA PCZZA Ed.14.
Multi-techno interoperability

This table lists the impacts over the service of some operating actions:
Action

Management system

Service impact

RRH reset

OMC 2G

Outage on 2G and 3G

WMS 3G

Re-initialisation of 3G SW
only,
No impact on 2G service

SUMx reset

OMC 2G

SUMx failure

No impact on RRH Call IP


service
No impact on 3G service

2G BTS SW replacement

OMC 2G

SW upgrade with RRH load:


outage of 2G and 3G service
SW upgrade without RRH
load: outage of 2G service, no
outage of 3G service

2G power setting

OMC 2G

No impact on 3G service

3G power setting

WMS 3G

No impact on 2G service

2G frequency setting

OMC 2G

No impact on 3G service

3G frequencies setting

WMS 3G

No impact on 2G service

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
5-4
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013

Index

A alarms

characteristics, 2-10

.............................................................

.............................................................

E equipment, 2-10

S sector

.............................................................

.............................................................

B bulkhead, 3-2

F frequency

.............................................................
C characteristics

alarms, 2-10

characteristics, 2-10
.............................................................
H height

depth, 2-10
frequency, 2-10
height, 2-10
sensitivity, 2-10
weight, 2-10
configurations
daisy chain, 4-2
repeater, 4-2

characteristics, 2-10
.............................................................
I

interfaces, 2-7

configurations, 4-2
sensitivity
characteristics, 2-10
star
configurations, 4-2
.............................................................
W weight

characteristics, 2-10

interoperability, 5-2
.............................................................
O OAM, 5-2

output power, 2-10


.............................................................

sector, 4-2
star, 4-2
connectors, 3-2
.............................................................
D daisy chain

configurations, 4-2
depth
characteristics, 2-10
documentation roadmap, 1-2

P processing, 2-4
.............................................................
R repeater

configurations, 4-2
requirement, 3-11
roadmap
documentation, 1-2
rules, 5-2

....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W