Title page
Alcatel-Lucent
Remote Radio Head 2X40W - 900 MHz for GSM and W-CDMA | UA08.1
Technical Description
NN-20500-281
Issue 02.05 | February 2013
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective
owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright 2013 Alcatel-Lucent. All rights reserved.
Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or copied or used by anyone outside
Alcatel-Lucent without its written authorization.
Not to be used or disclosed except in accordance with applicable agreements.
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
Contents
About this document
vii
Purpose ............................................................................................................................................................................................ vii
Reason for reissue
....................................................................................................................................................................... vii
vii
...................................................................................................................................................................... vii
vii
Intended audience
...................................................................................................................................................................... viii
viii
Supported systems
..................................................................................................................................................................... viii
viii
....................................................................................................................................................................... viii
viii
Related information
Document support
........................................................................................................................................................................ ix
ix
Technical support
........................................................................................................................................................................... x
x
How to order
.................................................................................................................................................................................... x
x
How to comment
1
..................................................................................................................................................................... ix
ix
............................................................................................................................................................................ x
x
Basic characteristics
Overview ...................................................................................................................................................................................... 2-1
2-1
Introduction ................................................................................................................................................................................. 2-2
2-2
Functional description ............................................................................................................................................................. 2-4
2-4
RRH external interfaces
......................................................................................................................................................... 2-7
2-7
Equipment characteristics
................................................................................................................................................... 2-10
2-10
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
iii
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Contents
....................................................................................................................................................................................................................................
Hardware description
Overview ...................................................................................................................................................................................... 3-1
3-1
RRH 2X40-09 Hardware description
................................................................................................................................ 3-2
3-2
...................................................................................................... 3-11
3-11
Configurations
Overview ...................................................................................................................................................................................... 4-1
4-1
Configurations ............................................................................................................................................................................ 4-2
4-2
Operating principles
Overview ...................................................................................................................................................................................... 5-1
5-1
OAM principles ......................................................................................................................................................................... 5-2
5-2
Index
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
iv
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
List of figures
1-1
2-1
2G-3G configuration
3-1
3-2
4-1
4-2
4-3
Combined configurations
4-4
Topology scheme
4-5
............................................................................................................................................... 2-3
...................................................................................................................................................... 3-5
3-5
....................................................................................... 4-4
....................................................................................................................................... 4-5
....................................................................................................................................................... 4-5
4-5
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
v
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
List of figures
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
vi
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
Purpose
The purpose of this document is to describe the Alcatel-Lucent Remote Radio Head
(RRH) that supports the following technologies:
2G (GSM)
3G (W-CDMA)
4G (LTE)
There are different variants of the RRH depending on the operational bandwidth and
depending on the transmitted power.
The RRH described here consists of two 900 MHz transmit paths of up to 40 W each path.
The document is about both 2G and 3G solutions, the 4G solution is not addressed. It is
called RRH 2X40-900.
Reason for reissue
Issue date
02.05
February 2013
Standard issue
02.04
November 2012
Standard issue
02.03
September 2012
Standard issue
02.02
September 2011
Preliminary issue
02.01
June 2011
Draft issue
New feature
...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
vii
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Intended audience
No specific recommendation applies regarding the way readers should read this
document.
Prerequisites
None
Conventions used
Vocabulary conventions
For a list of the terms used in this document, see Alcatel-Lucent W-CDMA System Terminology, NN-20500-002.
For convenience, the terms RRH 2X40-900, RRH 2X40-09, or RRH are also used in this
publication.
It means this RRH variant:
The Station Unit Module supported by the RRH 2X40-09 is the SUMX 19. The
abbreviation used is the document SUMx refers to the SUMX 19.
Important! The SUMP or the SUMA is not supported by the RRH 2X40-900.
Typographical conventions
Description
Italicized text
Emphasized information
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
viii
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
Related information
For information on subjects related to the content of this document, refer to the
documents listed in the following table:
Refer to this document
At this location
Alcatel-Lucent W-CDMA
System - Terminology,
NN-20500-002
http://support.alcatel-lucent.
com.
http://support.alcatel-lucent.
com.
http://support.alcatel-lucent.
com.
http://support.alcatel-lucent.
com.
Basic characteristics
Hardware description
Basic characteristics
Hardware description
Basic characteristics
Hardware description
http://support.alcatel-lucent.
com.
http://support.alcatel-lucent.
com.
Basic characteristics
Hardware description
Document support
For support in using this or any other Alcatel-Lucent document, contact Alcatel-Lucent at
one of the following telephone numbers:
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
ix
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Technical support
For technical support, contact your local Alcatel-Lucent customer support team. See the
Alcatel-Lucent Support web site (http://www.alcatel-lucent.com/support/) for contact
information.
How to order
To order Alcatel-Lucent documents, contact your local sales representative or use Online
Customer Support (OLCS) (http://support.alcatel-lucent.com)
How to comment
To comment on this document, go to the Online Comment Form (http://infodoc.alcatellucent.com/comments/) or e-mail your comments to the Comments Hotline
(comments@alcatel-lucent.com).
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
x
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
1oadmap to Distributed
R
Base Station
documentation
Overview
Purpose
This chapter provides the roadmap for Distributed Base Station documentation.
Contents
Roadmap to Distributed Base Stations documentation
1-2
...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
1-1
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
1-2
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
1-3
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
1-4
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
Basic characteristics
2
Overview
Purpose
2-2
Functional description
2-4
2-7
Equipment characteristics
2-10
...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
2-1
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Basic characteristics
Introduction
....................................................................................................................................................................................................................................
Introduction
Overview
The RRH is deployed in networks that support different technologies. Installing the
correct software is enough to migrate from one technology to another one.
It can also be shared by different operators (RAN sharing).
The RRH specified in this document operates in the following technologies:
Single technology
2G only (GSM)
3G only (W-CDMA)
4G only (LTE )1
2G/4G (GSM/LTE)1
3G/4G (W-CDMA/LTE ) 1
2G/3G/4G (GSM/W-CDMA/LTE) 1
3G/4G (W-CDMA/LTE)1
2G/3G/4G (GSM/W-CDMA/LTE1)
Note: 1
The RRH 2X40-09 is hardware ready to the support LTE technology but the feature is
not yet implemented.
The RRH performs the transmission and reception of radio frequencies in the
corresponding frequency band. It also performs the baseband processing. It consists of
one digital-analog board and two power amplifier boards. The RRH 2X40-900 operates in
a reduced bandwidth down to 4.2 MHz, thus, GSM and W-CDMA signals use the same
available spectrum.
The RRH 2X40 supports antenna diversity.
If the 3G (or 4G) technology is used, the RRH is linked to the d2U or to the BBU through
a CPRI interface and optical fibers.
If the 2G technology is used, the RRH is connected to the BSC through a central
equipment called Station Unit Module (SUMx). This equipment is hosted either in an
existing BTS rack, or in a dedicated Site Support Cabinet (SSC). The SSC also integrates
AC/DC converters and batteries for power back-up.
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
2-2
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
Basic characteristics
Introduction
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
2-3
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Basic characteristics
Functional description
....................................................................................................................................................................................................................................
Functional description
Introduction
Receives the signal coming from the CPRI or the ethernet interface.
Processes the signal.
Sents it to the radio interface.
Optical access
Configuration, supervision, alarm and failure monitoring
Part of call processing
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
2-4
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
Basic characteristics
Functional description
....................................................................................................................................................................................................................................
Optical access
This function provides duplex optical communication towards the Node B site through
optical fibers using Single-Mode or Multi-Mode propagation:
Configuration/supervision
This function is in charge of configuring and supervising the modules as well as ensuring
inventory information reporting.
The remote inventory functionality allows the W-CDMA OAM access to determine the
state of the RRH.
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
2-5
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Basic characteristics
Functional description
....................................................................................................................................................................................................................................
Call processing
The call processing function is in charge of radio resource management inside the base
station equipment. Call processing manages:
Transmission functions
Operations and maintenance tasks of the BTS
Remote inventory function
Clock distribution
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
2-6
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
Basic characteristics
....................................................................................................................................................................................................................................
Description
Power supply
Ground
Radio
CPRI1
Optical1
External alarms
AISG
Optical interfaces
There are two optical ports on the RRH: one master, one slave.
The optical mode (SM or MM) is given by the distance between the Node B and the
RRH.
The RRH master port is used in daisy chain mode to connect the second RRH.
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
2-7
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Basic characteristics
....................................................................................................................................................................................................................................
The RETA unit allows adjustment of the antenna tilt without tower climb, and depending
on configuration without site visit.
The AISG interface is used for RETA unit connection. It is also used to connect the Tower
Mounted Amplifier (TMA) when it is provided.
The AISG interface is controlled from the Node B digital unit. Control access is
performed on-site via a PC (loaded with a standard software) connected to the BBU or at
a remote location when using a remote access.
All physical and electrical specifications related to the RETA comply with the Antenna
Interface Standards Group (AISG).
SUMx
An existing BTS cabinet (with enough space for additional standard 19 equipment)
In a dedicated Site Support Cabinet (SSC)
The SSC integrates AC/DC converters and batteries for power backup.
In a distributed solution, the BTS (RRH 2X40W + SUMx) is connected to the BSC
through a TDM or IP transmissions.
The SUMx is connected to the RRH using three high speed optical connections.
The external interfaces are located at the front of the SUMx 19 box.
Interface
Description
Transmission interface
Radio
Power supply
48VDC
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
2-8
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
Basic characteristics
....................................................................................................................................................................................................................................
Interface
Description
External alarms
E1 connections
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
2-9
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Basic characteristics
Equipment characteristics
....................................................................................................................................................................................................................................
Equipment characteristics
Mechanical Data
RRH 2X40-09
without solar
shield
SUMx
Height (mm)
300
300
483
Width (mm)
443
460
56
Depth (mm)
150
154
313
< 18
Weight (kg)
Environmental Data
RRH 2X40-09
SUMx
Climatic requirements
Operationing temperature
5 C to +65 C.
Absolute humidity
Cooling method
1120 W/m 2
Acoustic noise
Noiseless
Electro Magnetic
Compatibility (EMC)
EN 300 132-2
EN 300 132-3
3GPP 25113
Safety
EN 60215
IEC 215
EN 60 950
IEC 950
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
2-10
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
Basic characteristics
Equipment characteristics
....................................................................................................................................................................................................................................
Electrical data
RRH 2X40-09
SUMx
Operating DC voltage
Power consumption
30 W (fully loaded)
390 W
42 W
Battery back- up
RF characteristics
RRH 2X40-09
880-915 / 925-960
TX output power
40 W max
Carriers
Rx Sensitivity (dbm)
-112
RX diversity
Yes
The RRH output power depends on the number of carriers configured per module and the
mix of technologies running.
The following table describes the output power values in case of pure GSM and
Multi-mode configurations for the RRH 2X40-09W.
Number of GSM
carriers
GMSK output
power class 2 (W)
GMSK output
power class 2 with
moderate power
overbooking (W)
8 PSK output
power (W)
40
40
27
40
40
27
17
17
11
17
17
11
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
2-11
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Basic characteristics
Equipment characteristics
....................................................................................................................................................................................................................................
Number of GSM
carriers
GMSK output
power class 2 (W)
GMSK output
power class 2 with
moderate power
overbooking (W)
8 PSK output
power (W)
13
15
13
15
The following table describes the output power values in case of W-CDMA configuration
or mixed configurations for the RRH 2X40-09W.
Configurations
40 W
40 W
2 carriers at 20 W
2 carriers at 20 W
1 carrier 20 W
3 carriers at 13 W
2 carriers at 20 W
3 carriers at 13 W
2 carriers at 20
4 carriers at 10W
RRH configuration
1120 W/m 2
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
2-12
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
Basic characteristics
Equipment characteristics
....................................................................................................................................................................................................................................
Miscellaneous
External alarms
8 for SUMx
Solar shield
The solar shield protects the RRH from solar radiation. It is factory-assembled to the
RRH main body.
Connection box (also called cable box)
The connection box protects the RRH bottom connectors from climatic conditions.
These bottom connectors are reachable through an access panel
Mounting kit
A mounting kit is required to install the RRH on a wall, a pole, or a floor.
Handle
The handle facilitates installation. This handle is factory-assembled to the RRH main
body and should be removed after installation.
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
2-13
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Basic characteristics
Equipment characteristics
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
2-14
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
Hardware description
3
Overview
Purpose
Contents
RRH 2X40-09 Hardware description
Node B hardware requirements for RRH support
3-2
3-11
...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
3-1
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Hardware description
....................................................................................................................................................................................................................................
Connector description
This topic gives an overview of the connectors located on the RRH bulkhead and on the
SUMx front pannel.
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
3-2
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
Hardware description
....................................................................................................................................................................................................................................
The external interfaces are located at the bottom side of the RRH housing.
Interface
Connector
DC power input
On unit side:
Ground
RETA
Protocol: RS-485
DC power specification: + 14 V DC
nominal
Antenna connections
External alarms
Ethernet interface
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
3-3
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Hardware description
....................................................................................................................................................................................................................................
Interface
Connector
1
Optical interfaces
1.
The optical interfaces support SFP transceivers which can be installed on field without
opening the RRH.
2.
The RRH master port is used in daisy chain mode to connect the second RRH.
3.
The optical mode (SM or MM) is given by the distance between the Node B and the RRH.
LED description
There is only one green-red bi-colored LED on the RRH. The BBU or the SUMx gets the
LED status periodically and reports it to the management system.
The following table lists the LED indicator states and the associated meaning.
LED status
RRH state
OFF
GREEN
BLINKING GREEN
RED
YELLOW
BLINKING YELLOW
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
3-4
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
Hardware description
....................................................................................................................................................................................................................................
The connection is located at the left side of the subrack front panel.
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
3-5
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Hardware description
....................................................................................................................................................................................................................................
Power supply
Ground
E1
External alarms
This table describes the connector used for the interface located on the SUMx front panel:
Interface
Connector
Ground
Power supply
HSE 1/2
SFP connector
High speed optical interfaces for Remote
Radio Head connection.
OPT1, OPT2
SFP connector
Optical interfaces for future use
XBCB
XRT
CLK1
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
3-6
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
Hardware description
....................................................................................................................................................................................................................................
Interface
Connector
BTS Terminal
External alarms
Test
GPS
SMB male
Provides a synchronization output from an
optional on-board GPS receiver
TRANS1
RJ-45
Provides traffic connection to the IP network
MMI-ETH
RJ-45
Used for connection with PC NEM
For local maintenance and configuration
purposes
AUX1
RJ-45
Connection for auxiliary equipment
There are eight LEDs on the SUMx front panel, which provide a visual indication of the
operational status of the SUMx module. The following table describes each LED and
defines the associated operational states.
SUMx LED description
LED
Color
P1
Yellow
P2
Yellow
Status
Description
Abis link 1 state
ON
Abis link 1
configured and ok
Blinking
Failure detected on
Abis link 1
OFF
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
3-7
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Hardware description
....................................................................................................................................................................................................................................
LED
P3
P4
OP
OMTr
Color
Status
Description
ON
Abis link 2
configured and ok
Blinking
Failure detected on
Abis link 2
OFF
Yellow
Abis link 3
configured and ok
Blinking
Failure detected on
Abis link 1
OFF
Yellow
Abis link 4
configured and ok
Blinking
Failure detected on
Abis link 4
OFF
Yellow
Yellow
Operational status
ON
Module in
operational status
Short blinking
Mismatch between
SW running on the
board and SW
version set by the
management system
Blinking
Transient state to
reach operational
state
Fast blinking
OFF
Module is not in
operational status
Status of the O&M transmission link
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
3-8
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
Hardware description
....................................................................................................................................................................................................................................
LED
ON
Color
Status
Description
ON
OML connection
established
Blinking
Transient state
corresponding to the
OML connection
establishment
Fast blinking
Searching of the
OML on the Abis
(Scanning mode)
OFF
OML disconnected,
no ongoing attempt to
establish the OML
connection
Green
FAULT
Power status
ON
SUMx powered ON
OFF
Red
Alarm status
ON
Fatal alarm on
SUMX or on any
SBL inside the BTS
Blinking
Short blinking
OCXO warm up
OFF
No alarm
The backplane is a multi-layer PCB. It distributes the 48/ 60 V DC, to power the
subrack equipment, and the digital signals to the SUMx module.
On the rear side of the back panel there is a Ribbon Cable C 64 M (DIN 41612)
connector. It is used to interconnect the subracks and the SUMx 19poste for future
applications.
The Abis Interface is the digital interface to the BSC. The SUMx provides four G.703
Abis interfaces.
They support the following communications links:
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
3-9
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Hardware description
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
3-10
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
Hardware description
....................................................................................................................................................................................................................................
2G
SUMX 19
3G
Most relevant d2U
versions and
modules: x and e
modules
2G/3G
Most relevant d2U
versions and
modules: x and e
modules
SUMX 19
RRH
MC-RRH 2X40-09
supporting 2G only
mode
MC-RRH 2X40-09
supporting 3G only
mode
RRH 2X40-09
supporting 2G and
3G mixed mode
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
3-11
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Hardware description
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
3-12
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
Configurations
4
Overview
Purpose
4-2
...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
4-1
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Configurations
Configurations
....................................................................................................................................................................................................................................
Configurations
Radio configurations
Star
Daisy-chain
Sector or repeater
Full 2G module
Full 3G module
2G/3G module
In a full GSM configuration, the SUMx is directly connected to the RRH 2X40W with
optical Ethernet cables (max. six RRH), while in a multistandard configuration the SUMx
is connected to the W-CDMA/LTE BBU module by the optical Ethernet cable and CPRI.
Star configuration
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
4-2
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
Configurations
Configurations
....................................................................................................................................................................................................................................
More cells can be provisioned by daisy-chaining three RRHs (or RFMs) to a single fiber
link coming from the BBU, or the SUMx.
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
4-3
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Configurations
Configurations
....................................................................................................................................................................................................................................
Sector mode to use the RRH as another remote sector not configured at Node B
Repeater mode to use the RRH as a local sector configured at Node B. This allows to
extend coverage of a local sector to rural or shadow areas.
When RRHs are used as repeaters on a 20-km optical fiber length, the cell size (set at the
OMC) of the last RRH in the daisy-chain cannot exceed 5 km.
To guarantee a continuity in mobility coverage, RRH cell management is based on the
following parameters:
Cell size
Soft handover (SHO) between local and remote cells
Combined configurations
The connection scheme can also be a combination of chain and ring and star as shown in
the next figure.
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
4-4
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
Configurations
Configurations
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
4-5
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Configurations
Configurations
....................................................................................................................................................................................................................................
Multi-Standard configuration
The RRH can also be configured in a multi-technology environment as shown in the next
figure.
Figure 4-5 Multi-standard configuration
GSM
SUMx 19
HSO
RRH
2G/3G
CPRI
RRH
2G/3G
CPRI
HSO
W-CDMA
d2u v2 / BBU
RRH
2G/3G
HSO
CPRI
To extend mobility coverage without adding cells to a Node B, Multiple RRH Sets (MRS)
can be used following the next rules:
An MRS contains one Cell-Mode RRH (CM RRH) acting as a normal cell, and
several Repeater-Mode RRHs (RM RRHs) acting as repeaters.
Up to four RM RRHs can be set in star or daisy-chain configuration.
Up to three MRSs can be connected to a d2U Node B in star configuration; and up to
six in daisy-chain configuration.
One MRS can support up to 12 cells and up to four carriers.
One BBU can support up to 12 RRHs.
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
4-6
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
Operating principles
5
Overview
Purpose
This chapter provides the RRH 2X40 operating rules according to the configuration
modes.
Contents
OAM principles
5-2
...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
5-1
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Operating principles
OAM principles
....................................................................................................................................................................................................................................
OAM principles
OAM mastership rules
OMC 2G
NA
3G BBU
NA
WMS 3G
OMC 2G
NA
RRH 3G PA
NA
WMS 3G
OMC 2G
WMS 3G
OMC 2G
NA
NA
WMS 3G
Tx path
Inventory
RRH 2G inventory, including
TMA
OMC 2G
NA
RRH 3G inventory
NA
WMS 3G
OMC 2G
NA
3G d2U inventory
NA
WMS 3G
Software management
RRH software
download/activation
OMC 2G
NA
OMC 2G
WMS 3G
NA
WMS 3G
Power management
RRH 2G PA
OMC 2G
NA
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
5-2
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
Operating principles
OAM principles
....................................................................................................................................................................................................................................
RRH 3G PA
NA
WMS 3G
Frequency management
RRH 2G PA Frequency
configuration
OMC 2G
NA
RRH 3G PA Frequency
configuration
NA
WMS 3G
OMC 2G
WMS 3G
OMC 2G
NA
OMC 2G
NA
3G
NA
WMS 3G
Switching mode
OMC 2G
NA
OMC 2G
NA
OMC 2G
NA
OMC 2G
NA
Counter support
2G
OMC 2G
NA
3G
NA
WMS 3G/NPO
NA
WMS 3G
Commissioning
RRH
NEM
NA
Capacity licensing
3G capacity licensing
(frequencies/power) for 3GPA
NA
WMS 3G
2G capacity licensing
OMC 2G
NA
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
5-3
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Operating principles
OAM principles
....................................................................................................................................................................................................................................
(*) Note : Due to the software achitecture in 2G/3G MC-RRH, recovery actions
performed on 3G VSWR part have to be also performed on the 2G part. For more details
refer to document BTS Alarm Dictionary / BTS Document / Reference Guide Release
B11 / 3BK 21625 AAAA PCZZA Ed.14.
Multi-techno interoperability
This table lists the impacts over the service of some operating actions:
Action
Management system
Service impact
RRH reset
OMC 2G
Outage on 2G and 3G
WMS 3G
Re-initialisation of 3G SW
only,
No impact on 2G service
SUMx reset
OMC 2G
SUMx failure
2G BTS SW replacement
OMC 2G
2G power setting
OMC 2G
No impact on 3G service
3G power setting
WMS 3G
No impact on 2G service
2G frequency setting
OMC 2G
No impact on 3G service
3G frequencies setting
WMS 3G
No impact on 2G service
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
5-4
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013
Index
A alarms
characteristics, 2-10
.............................................................
.............................................................
E equipment, 2-10
S sector
.............................................................
.............................................................
B bulkhead, 3-2
F frequency
.............................................................
C characteristics
alarms, 2-10
characteristics, 2-10
.............................................................
H height
depth, 2-10
frequency, 2-10
height, 2-10
sensitivity, 2-10
weight, 2-10
configurations
daisy chain, 4-2
repeater, 4-2
characteristics, 2-10
.............................................................
I
interfaces, 2-7
configurations, 4-2
sensitivity
characteristics, 2-10
star
configurations, 4-2
.............................................................
W weight
characteristics, 2-10
interoperability, 5-2
.............................................................
O OAM, 5-2
sector, 4-2
star, 4-2
connectors, 3-2
.............................................................
D daisy chain
configurations, 4-2
depth
characteristics, 2-10
documentation roadmap, 1-2
P processing, 2-4
.............................................................
R repeater
configurations, 4-2
requirement, 3-11
roadmap
documentation, 1-2
rules, 5-2
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X40W
Alcatel-Lucent Proprietary
IN-1
NN-20500-281 UA08.1
Use pursuant to applicable agreements
Issue 02.05 February 2013
Index
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
Alcatel-Lucent RRH 2X40W
IN-2
Use pursuant to applicable agreements
NN-20500-281 UA08.1
Issue 02.05 February 2013