1.0 Purpose:
This Procedure is intended to provide guidance and instructions for carrying out the F.D Fans
Maintenance
2.0 Constructional Features :
When looking in floor direction, the fan consists of the following components.
Stator consisting of Suction Box, Fan housing, Outlet guide vane housing with guide
vanes and diffuser.
Rotor consisting of shaft, one impeller with blades, the blade bearing assemblies, the
hydraulic impeller blade adjustment system and Main bearing assy (Anti-friction bearings)
SI.No
Fan Component
1
2
Suction Box
Diffuser
Silencer
OGV Assembly
5
6
7
8
9
10
11
Impeller Housing
Shaft with Brg Assy
Impeller and Hydraulic Adjustment device
Spring Shackle coupling
Machined packers and shims
Instruments
Lub oil system
Storage Location
Outdoor(a)
Outdoor(a)
Weather Protected
(b)
Weather Protected
(b)
Weather Protected
(b)
Indoor
Indoor
Indoor
Indoor
Indoor
Indoor
Frequency of
Inspection (D)
Monthly
Monthly
Monthly
Monthly
Monthly
Monthly
Monthly
Monthly
Monthly
Monthly
Monthly
Page 3 of 10
Application
Brand Name
TRP
De-oxy Aluminates
Oil ISO VG 68 Equivalent : SERVO PRIME 68
Page 4 of 10
Maintenance of Fan
Prior to taking the equipment out of service during a planned maintenance program, the
following checks are to be carried out. These checks are designed to help in scheduling the
maintenance activity and to avoid unforeseen delays in re-commissioning the Fan.
Record vibration level on all bearings. Such of those bearings whose vibration levels
are beyond the permissible levels of satisfactory operation may be subjected to
vibration/ signature analysis to carry out the corrective actions.
Ensure the availability of operational data such as vibration level, Bearing
temperature, Motor amperage, blade position etc before stopping the Fan.
Pay Specific attention to any abnormal noise emanating from any of the machine
components like bearings etc.
Observe for any leakage in the fan like oil, air at Fan connections etc. Observe for
any erosion of impeller/ Casing.
Availability of operational spares and other materials in connection with the
observations made above.
After the Fan is stopped the following data may be recorded / ensured for reference
during re commissioning.
Couple alignment.
Marking the assembled components by match marks.
Servo motor operating time.
Actuator linearity w.r.t control room indication and actual blade position.
Clean the lub oil filter. Clean it before the above mentioned time has elapsed when the
differential pressure contact indicator indicates that the filter is dirty.
Test the oil, if water is found, find the cause and eliminate it.
Page 5 of 10
Forced Shutdown
If the plant shutdown is owing to other parts, it may be possible to inspect the Fan. We
recommend the following jobs.
Planned Shutdown
We recommend to effect overhaul for every 8000 to 10000 operating hours or at least once in
two years. This job should be performed under the guidance of the specialist of the Fan
manufacturer.
a) Check on Impellers
b)
c)
d)
e)
f)
g)
Effect all checks as described under between planned shut down and forced shut down
Clean inlet and outlet oil lines.
Eliminate oil leakage
Check the clearance of main bearings.
Ensure free rotation of Fan rotor by hand freely.
Replace correct oil hoses for hydraulic adjustment device if required.
Page 6 of 10
BHEL specialist should service Fan. Our instructions have only one objective, namely to keep the
Fan ready for operation and to avoid longer standstills. Basic requirements for the installation and
removal of such parts are a clean job and avoidance of any kind of force.
Lubrication InstructionsThe lubricating oil for the fan bearings are supplied by the centralized oil pumps which supply oil
for the hydraulic servomotor also. It must be borne in mind that the quality of oil flowing to the
bearings and its pressure must be maintained as recommended. The flow control device provided
in the oil system ( lube oil inlet fine) is to be covered arid protected.
The oil to be used shall be a turbine quality oil to suit the following specifications :
ISO Viscosity Grade
:
Kinematic Viscosity at 40C
:
Viscosity Index
:
Flash Point
Pour Point
Neutralization No-mg KOH/gm
68
64-72 cst
95 min
: 210C
: -6C (max)
: 0.2
The oil must not foam during operation. Foam removing agents containing silicon must not be
utilised. The oil must have good anti-corrosion properties.
Lubricant FillingFill the recommended lube oil ( through a fine mesh strainer only) up to the required level.
Do not mix lubricants of different grade and make.
Lubricant CheckAt first commissioning and after a basic overhaul, the entire oil must be drained after an
operating period of 100 hrs. All dirt should be eliminated from the oil tank. Then fill in again the
oil through the fine mesh strainer.
Care of LubricantTest the quality of the oil every month and if found unsatisfactory and oil containing water/dirt
the oil should be changed immediately. The maximum permissible limit of contamination is 100
ppm.
Page 7 of 10
SI.N
o
Compone
nt
Lubrican
t
Servo
prime 68
Fan main
Turbinol
bearings and
68
hydraullic
Bharat
adjustment
turbol 68
device.
Tersso
68
Mobil
Glygolye
Blade shaft
30 and
bearing
Mobil
assembly
grease 28/
Burutox
M21
Blade shaft
bearing
Molykote
bushing and microfine
pushrod
graphite
guide
powder
bushing
Bearing
shaft and
indication
shaft
Mobil
grease 28/
Burutox
M21
Blade bolt
and other
bolt
Molykote
1000
paste
Suppli
er
M/s IOC
M/s
HPC
M/s BPC
(Others)
See
note.3
See
note.3
See
note.3
Locatio
n
Frequen
cy
Observati
on
Qty/Fa
n
Oil tank
Once in 2
years or
based on
the oil
quality see
note 2
Daily
See
note 1
Inside
Rotor
During
over haul(
once in 2
years) see
note 4
****
10 Ltr,
1 Kg
Inside
Rotor
During
over haul(
once in 2
years) see
note 4
****
0.5 Kg
Outside
Rotor
During
over haul(
once in 2
years) see
note 4
****
0.2 Kg
Commo
n
0.5 Kg
Page 8 of 10
Notes :
1. Oil quantity depends on tank capacity. Levels marked in the oil tank level guage.
2. The frequency of filling shown is for normal operation follow lubricating instructions given
in this manual.
3. The blade bearing assembly lubricants are presently imported. Development of
indigenous supplier is under study.
4. The lubricants of blade bearing assembly are renewed only during major overhaul of the
Fan (usually once in two years). This has to be done only by trained person. BHEL person
may be requisitioned for supervision.
Recommended list of spares
We recommended stocking at least one set of the components per boiler shown in the diagram
of Rotor assembly, Shaft with bearing assembly, and blade bearing assembly, as spare to meet
the O&M requirement apart from having a stock of one assembled set of rotor assembly to meet
emergency requirement.
APPLICATION
FAN TYPE
FAF 24/11.8-1
NO/BOILER
MEDIUM
LOCATION
ATMOSPHERIC AIR
OUTDOOR
235
50
DENSITY(KG/M)
1.054
SPEED(RPM)
990
TWO
390
FAN REVERSE
FLOW(%)
42.6
PRESSURE(%)
63.8
SPACER TYPE
BHEL
TYPE
RATING (KW)
1200
994
SPEED(RPM)
Page 9 of 10
10
Page 10 of 10
6600
LUBRICATING EQUIPMENT
FAN
MOTOR
GREASE LUBRICATED(SERVOGEM-3)
12 BEARINGS
FIXED BEARING
7248 C3
FREE BEARING
NU 236 C3