1. goal
This Technical Report is intended to attest to the technical conditions of the
Network Infrastructure and Wireless Local Company Eco Paradise Hotel located on
the street Sweden, 28 - Cumbuco - Ceara, assessing their compliance with the
Technical Standards applicable.
2. methodology
The procedure used in the preparation of this Technical Report was to record
images through all components of the Network.
Upon audit, were recorded every detail observed by Specialized Technical
Network, identifying and qualifying all components pointing needs correcting
nonconformities cleared.
In the office, the Network Engineer and Telecommunications, in possession of all
the data, prepared the Technical Report identifying each component through
image and commenting nonconformities according to the applicable Technical
Standards.
3. REFERENCED STANDARDS
1. EIA/TIA 568-B.1 Specification of a generic system of telecommunications
cabling for buildings;
2. EIA/TIA 568-B.2 Specification of cabling components, transmission, system
models and measurement procedures required for the verification of twisted
pair cabling;
3. EIA/TIA 569-A Telecommunications pathways and spaces for the internal
network. (structured cabling structured Infrastructure);
4. EIA/TIA 606-A Administration of telecommunications infrastructure;
5. ISO/IEC 11801 Standards for Structured Cabling System
6. NBR 14565 Basic procedures for the preparation of projects for
telecommunications cabling structured internal network;
7. NBR 5413 e NR 17 - Ergonomics and illuminance
8. IEEE 802 - Establishes international standards related to local networks.
Photos 2:
Photos 3:
4.4. RJ 45 exposed
RJ 45 connector above the ground.
The network environment must be organized so that their connections are not
exposed and vulnerable to physical exertion, causing breakage or rupture.
Network components such as cables and connectors must always be protected.
Besides doing an installation within the IEEE 802 standards with the use of
accessories available, it is necessary to guide users when and how to use the care
that must be given to the connections.
The RJ 45 on the ground can suffer mechanical stress being damaged and you may
come in contact with electrical outlet (filter), conducting electrical current through
the logical network, causing burning equipment and cause electric shock to any
user.
Photos 4:
Network cables with induction level above that allowed with the risk of
burning equipment, electric shock to the user, locking the network, speed
loss and other problems.
6. general aspects
All network cables must be identified in accordance with its purpose, in case
of identification by color, Link (INTERNET) should be identified with the
color-Light Gray, cables connecting users (Local Area Network) should be
identified with the color Blue, Wireless network cables should be identified
with the color Blue-course.
Distribution cables from the local network must be reinstalled so that the
insulation of the cable does not come into direct contact with power cables,
as failure isolation (caused by cracks or dryness) may result in electric shock
or burns equipment.
Plants, diagrams, descriptive text, and other documents that make up the
project, should be executed or updated in order to become part of the
premises documents Infrastructure Network (chart provided in NR 10).
7. CONCLUSION
This Technical Report included the analysis of Network Infrastructure Logic
indicating non-conformities and suggesting regulatory actions.
As primary recommendation, we suggest the immediate shutdown of all network
cables to avoid possible damage to equipment, and reinstallation of the entire
structure of cables, with the completion of design and documentation of the
structure of the points, so that it remains the integrity of the facility and the
adequacy of the same technical standards.
As a complement to this work, it is recommended the immediate implementation
of the entire installation.
Caucaia, April 30, 2013.