Documente Academic
Documente Profesional
Documente Cultură
3/0
Contents
3/1
Selection guide
Applications
These timing relays enable simple automation cycles to be set up using wired logic.
They can also be used to complement the functions of PLCs.
Output
Solid state
Timing relays with solid state output reduce
the amount of wiring required (wired in
series). The durability of these timing relays
is independent of the number of operating
cycles.
Relay
Relay outputs provide complete isolation
between the supply and outut circuits.
It is possible to have several output circuits.
Type
Modular
Modular
Timing ranges
7 ranges :
1 or 2 ranges,
7 ranges :
1 s, 10 s, 1 min, 10 min, depending on model : 1 s, 10 s, 1 min, 10 min,
1 h, 10 h, 100 h
10 s, 30 s, 300 s,
1 h, 10 h, 100 h
60 min
Relay type
Pages
3/2
Industrial
3/10
Industrial
Depending on model :
4 ranges :
0.6 s, 2.5 s, 20 s, 160 s
7 ranges :
1 s, 10 s, 1 min, 10 min,
1 h, 10 h, 100 h
7 ranges :
1 s, 3 s, 10 s, 30 s,
100 s, 300 s, 10 min
10 ranges :
1 s, 3 s, 10 s, 30 s,
100 s, 300 s, 30 min,
300 min, 30 h, 300 h
3/18 to 3/23
and 3/26 to 3/29
These timing relays enable simple automation cycles to be set up using wired logic.
They can also be used to complement the functions of PLCs.
Relay
Relay outputs provide complete isolation between the supply and output circuits.
It is possible to have several output circuits.
3
Optimum
Plug-in
Panel-mounted
Universal
Miniature
Analogue
1 range,
depending on model :
0.5 s, 3 s, 10 s, 30 s, 300 s,
30 min
7 ranges :
1 s, 10 s, 1 min, 10 min, 1 h,
10 h, 100 h
7 ranges :
Depending on model :
1 s, 10 s, 1 min, 10 min, 6 ranges :
1 h, 10 h, 100 h
1 s, 10 s, 1 min,
10 min, 1 h, 10 h
8 ranges :
1 s, 10 s, 1 min, 4 min,
10 min, 1 h, 10 h, 60 h
RE8
RE 88 867 ///
3/34 to 3/37
3/40 to 3/45
3/47
(1)
Digital
Electromechanical
Depending on model :
7 ranges :
99.99 s, 999.99 s,
99 min 59 s, 99.99 min,
999.9 min, 99 h 59 min,
999.9 h
11 ranges :
99.99 s, 999.99 s,
9999 s, 99 min 59 s,
99.99 min, 999.9 min,
9999 min, 99 h 59 min,
99,99 h, 999.9 h,
9999 h
Depending on model :
3 ranges :
6 s, 60 s, 12 min
3 ranges :
6 min, 60 min, 12 h
3/51, 3/55
and 3/57
(1)
3/3
Characteristics
Timing characteristics
Repeat accuracy
(with constant parameters)
Drift
Temperature
Voltage
Setting accuracy at full scale Conforming to IEC 1812-1
Minimum duration of
Typical
control impulse
Maximum reset time
Typical
by de-energisation
Immunity time
Typical
to microbreaks
0.5 %
ms
0.05 % / C
0.2 % / V
10 % at 25 C
50
ms
350
ms
> 10
Supply characteristics
Multivoltage supply
Frequency
Operating range
On-load factor
Maximum power
consumption
$ 24 V
$ 240 V
"240 V
W
VA
1.5
32
Hz
Depending
on model
Output characteristics
Output type
Breaking capacity
Derating
Maximum permissible current
Minimum breaking current
Leakage current
Maximum switching voltage
Typical voltage drop at terminals
Electrical life
Mechanical life
Dielectric strength conforming to IEC 664, IEC 255-5
A
mA
A
mA
mA
V
kV
Solid state
"/$0.7 at 20 C (0.5 A UL)
5 / C
20 10 ms
10
<5
"/$ 250
3-wire 4V - 2-wire 8V
108 operations
108 operations
2.5 at 1 mA / 1 min
Display characteristics
State indication
by 1 LED
Green
Input characteristics
Input type
References :
pages 3/6 and 3/7
3/4
Dimensions :
page 3/6
Schemes :
page 3/7
Characteristics (continued)
General characteristics
Conforming to standards
Product certifications
Temperature limits
Operation
Storage
C
C
- 20+ 60
- 30+ 60
Creepage distance
and clearance
Degree of protection
conforming to IEC 529
kV
4 kV/3
Terminal block
Enclosure
Panel-mounted
IP 20
IP 40
IP 50
Vibration resistance
f = 1055 Hz
A = 0.35 mm
Relative humidity
without condensation
Electromagnetic
compatibility
93 %
Immunity to electrostatic
discharge, conforming to
IEC 1000-42
Immunity to electromagnetic
fields, conforming to
ENV 50140/204 (IEC 1000-4-3)
Immunity to fast transients in
bursts, conforming to
IEC 1000-4-4
Immunity to surges
on the power supply
conforming to IEC 1000-4-5
Immunity to radio frequency
interference in common mode
conforming to ENV 50141
(IEC 1000-4-6)
Immunity to voltage dips and
breaks conforming to
IEC 1000-4-11
30 % / 10 ms
60 % / 100 ms >
95 % / 5 s
Class B
References :
pages 3/6 and 3/7
mm
35
mm2
mm2
2 x 2.5
2 x 1.5
mm2
mm2
1.5
2.5
Self-extinguishing
Dimensions :
page 3/6
Schemes :
page 3/7
3/5
References,
dimensions,
schemes
Function diagrams
Function A
Function H
Delay on energisation
Timing on energisation
Pulse-on energisation
U
R
T1 T2
Function B
Function Li
Asymmetrical recycler
Pulse start
Function L
Function Di
Asymmetrical recycler
Start after pause
R
T1 T2
T T
560847
560848
References
Connection
Functions
Screw terminals
Timing ranges
Rated current
Voltages
7 ranges
24240 V "50/60 Hz
24240 V "/$50/60 Hz
Weight (kg)
/
Multifunction
A - At - B - C - H - Ht - Di - D - Ac - Bw
1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
0.7 A
RE 88 826 004
0.060
/
Single function
A
0.7 A
RE 88 826 014
0.060
44
81
45
3,5
60
5,5
Characteristics :
pages 3/4 and 3/5
3/6
Schemes :
page 3/7
Function C
Function At
Function Ht
Function D
Function Bw
Timing on energisation
with memory
Delay on energisation
with memory
t1
C
T T
t2
T = t1+t2
t1
t2
T = t1+t2
Function Ac
Timing after closing/opening
of control contact
U
C
R
560849
560848
/
Single function
H
1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
0.7 A
RE 88 826 044
0.060
/
Dual function
Li - L
0.7 A
RE 88 826 054
0.060
Connection schemes
Functions A, H
Function U
Functions L, Li
A1
A1
A1
A2
Y1
A2
Y1
MULTI
A2
18
R
Y1
18
R
(1)
Characteristics :
pages 3/4 and 3/5
Dimensions :
page 3/6
3/7
Characteristics
560853
Presentation
The RE9 range of relays is designed for simple, repetitive applications with short and
intensive cycles because their solid state output provides very high electrical
durability.
Each relay has a single timing range.
Each relay has a wide voltage range from 24 to 240 V.
The range comprises 9 references with 3 model types:
# RE9-TA: function A,
# RE9-RA: function C,
# RE9-MS: multifunction A, H, L, Li.
These products have a transparent, hinged flap on their front face to avoid any
accidental alteration of the settings. This flap can be directly sealed.
Environment
Conforming to standards
Product certifications
CSA, GL pending. UL
&marking
Zelio Time timing relays conform to European regulations relating to & marking
Storage
Operation
Conforming to IEC 60721-3-3
C
C
- 40+ 85
- 20+ 60
1585 % Environmental class 3K3
a = 0.35 ms
Degree of pollution
Casing
Terminals
Conforming to IEC 60664-1
IP 50
IP 20
3
Overvoltage category
III
Conforming to IEC
Conforming to CSA
V
V
250
300
Dielectric test
Shock wave
kV
kV
2.5
4.8
Voltage limits
Frequency limits
Disconnection value
> 0.1 Uc
Mounting position
without derating
Cabling
Maximum c.s.a.
In relation to normal
vertical mounting plane
Flexible cable without cable end mm2
Flexible cable with cable end
mm2
Any position
Tightening torque
N.m
Shock resistance
Degree of protection
15 gn - 11 ms
0.851.1 Uc
Hz
50/60 5 %
2 x 2.5
2 x 1.5
0.61.1
Electromagnetic fields
Fast transients
Level 3 (2 kV)
Shock waves
Level 3 (2 kV)
CISPR11
Group 1 class A
CISPR22
Class A
References :
page 3/10
3/8
Dimensions :
page 3/10
Schemes :
page 3/11
Characteristics
(continued)
RE9-TA
On-delay
RE9-RA
Off-delay
RE9-MS
Multifunction
7 24240
" 24240
7 24240.
See page 3/10
In series
Between Y2 and A2
In series
Supply characteristics
Supply voltage
Voltage limits
V
Of the control circuit
0.851.1 Un
Frequency
Hz
5060 5 %
Control contact
Mechanical only
Maximum length of
connecting cable
Control input consumption
20
Input Y2
mA
Timing characteristics
Setting accuracy
< 20 %
Repeat accuracy
<1%
Maximum immunity
to microbreaks
ms
ms
100
40
ms
ms
100
2
70
2
Temperature drift
15 for 10 ms
At 0.7 A: 3
Leakage current
Open state
mA
2.5
2.5
mA
Without
> 100
References :
page 3/10
Dimensions :
page 3/10
Schemes :
page 3/11
3/9
Functions,
references,
dimensions
Function diagrams
Function A
Function C
Function H
Delay on energisation
Off-delay
Timing on energisation
Pulse-on energisation
Supply
Supply
Supply
Control
contact K
Load
Load
Load
Function Di
Function D
Supply
Supply
Control
contact K
Control
contact K
Load
Load
==
t t
= =
t t
Functions
Voltages
Timing ranges
Weight (kg)
A
/
RE9 TA11MW
RE9 TA31MW
RE9 TA21MW
RE9 TA51MW
0.110
560855
560855
560854
References
/
RE9 RA11MW7
RE9 RA31MW7
RE9 RA21MW7
RE9 RA51MW7
0.110
A, H, D, Di
/(A)
/(H, D, Di)
RE9 MS21MW
RE9 MS21MW
0.110
Dimensions
Rail mounting
Screw fixing
78
6
78
80
89,5
82
Characteristics :
pages 3/8 and 3/9
3/10
Schemes :
page 3/11
Schemes
Terminal blocks
RE9 TA
RE9 RA
A1
RE9 MS
A1
A1
X4
Y2
A2
X1
X2
X3
RE9-TA
K
A1
Load
The timing relay is placed in series, with the load whose de-energisation is to be delayed on one
side and switch K on the other side. The mains supply may be a.c. or d.c. and the voltage may
be between 24 V and 240 V. See function diagram on page opposite.
Load
The timing relay is placed in series with the load whose de-energisation is to be delayed. Switch
K is connected to terminals Y2 and A2 of the timing relay, and terminal A2 is connected to the
mains supply, as indicated in the diagram opposite. The device is operated from an a.c. mains
supply whose voltage is between 24 V and 240 V. See function diagram on page opposite.
Supply " or $
RE9 RA
RE9-RA
A1
Y2
A2
Supply " or $
RE9 MS
Delay on energisation
Function A
Pulse-on energisation
Function H
Selection of the timing range
X3 X4
A1
Load
A1
A2
X1
K
A1
RE9-MS
X3 X4
Load
A1
A2
RE9-MS
Supply " or $
Supply "
Symmetrical flasher
Start with output in the operating position
Function Di
Symmetrical flasher
Start with output in the rest position
Function D
X1 X2 X3 X4
K
A1
X2 X3 X4
Load
A1
A2
A1
Load
A1
A2
RE9-MS
RE9-MS
Supply "
Supply "
Note : For supply voltages greater than 30 V, the rated voltage of the load is equal to the supply voltage. For a supply voltage of 24 V, the voltage drop within the
RE9 relay must be taken into account (about 3 V); a coil with a nominal voltage of 21 V must therefore be selected for the load.
Characteristics :
pages 3/8 and 3/9
Dimensions :
page 3/10
3/11
Characteristics
Timing characteristics
Repeat accuracy
(with constant parameters)
Drift
Temperature
Voltage
Setting accuracy at full scale Conforming to IEC 1812-1
Minimum duration of
Typical
control impulse
Typical under load
Maximum reset time
Typical
by de-energisation
Immunity time
Typical
to microbreaks
0.5 %
ms
ms
ms
0.05 % / C
0.2 % / V
10 % at 25 C
30
100
100
ms
> 10
Supply characteristics
Multivoltage supply
Frequency
Operating range
On-load factor
Maximum
power consumption
$ 24 V
$ 240 V
"240 V
W
VA
1.5
32
Hz
Depending
on model
Output characteristics
Output type
Breaking capacity
Maximum breaking current
Minimum breaking current
Maximum switching voltage
Electrical life
Mechanical life
Dielectric strength
Impulse voltage
A
mA
V
kV
kV
Display characteristics
State indication by 1 LED
Green
Input characteristics
Input type
References :
pages 3/13 and 3/14
3/12
Dimensions :
page 3/14
Schemes :
page 3/15
Characteristics (continued)
General characteristics
Conforming to standards
Product certifications
Temperature limits
Operation
Storage
C
C
- 20+ 60
- 30+ 60
kV
4 kV/3
Terminal block
Enclosure
Panel-mounted
IP 20
IP 40
IP 50
Vibration resistance
f = 1055 Hz
A = 0.35 mm
Relative humidity
without condensation
Electromagnetic
compatibility
93 %
Immunity to electrostatic
discharge, conforming to
IEC 1000-42
Immunity to electromagnetic
fields, conforming to
ENV 50140/204 (IEC 1000-4-3)
Immunity to fast transients in
bursts, conforming to
IEC 1000-4-4
Immunity to surges on the
power supply, conforming to
IEC 1000-4-5
Immunity to radio frequency
interference in common mode
conforming to ENV 50141
(IEC 1000-4-6)
Immunity to voltage dips
and breaks conforming to
IEC 1000-4-11
30 % / 10 ms
60 % / 100 ms >
95 % / 5 s
Class B
References :
pages 3/13 and 3/14
mm
35
mm2
mm2
2 x 2.5
2 x 1.5
mm2
mm2
1.5
2.5
Self-extinguishing
Dimensions :
page 3/14
Schemes :
page 3/15
3/13
References,
dimensions,
schemes
Function diagrams
Function A
Function H
Timing on energisation
Pulse-on energisation
Asymmetrical recycler
Pulse start
R
T1 T2
Function B
Function Li
Delay on energisation
Function L
Function Di
Asymmetrical recycler
Start after pause
R
T1 T2
T T
Connection
Screw terminals
Spring terminals
Functions
Timing ranges
Rated current
Voltages
7 ranges
$24 V / "24240 V
"/$ 12240 V
Weight (kg)
560851
560850
560851
References
/
/
Multifunction
Dual function
A - At - B - C - H - Ht - Di - D
A - At
Ac - Bw
1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
8A
8A
RE 88 826 105
RE 88 826 115
0.060
0.060
Single function
B
8A
RE 88 826 125
0.060
44
81
45
3,5
60
5,5
Characteristics :
pages 3/12 and 3/13
3/14
Schemes :
page 3/15
Function C
Function At
Function Ht
Function D
Function Bw
R
t1
t2
T = t1+t2
C
T T
t1
R
T
t2
T = t1+t2
Function Ac
Timing after closing/opening
of control contact
U
C
Single function
C
560850
560852
560851
560851
560850
Dual function
H - Ht
Dual function
Li - L
Multifunction
A - At - B - C - H - Ht - Di D - Ac - Bw
/
Multifunction
A - At - B - C - H - Ht - Di D - Ac - Bw
0.060
0.060
8A
RE 88 826 155
0.060
8A
RE 88 826 103
0.060
8A
RE 88 826 503
0.060
Connection scheme
All functions except L and Li
Functions L and Li
U
U
+
+
(1)
A1
Y1
A1
15
R
Y1
15
R
A2
A2
16 15
16 18
Characteristics :
pages 3/12 and 3/13
Dimensions :
page 3/14
3/15
Characteristics
Timing characteristics
Repeat accuracy
(with constant parameters)
Drift
Full scale setting accuracy
Minimum duration of
control impulse
Maximum reset time
by de-energisation
Immunity time
to microbreaks
0.5 %
Temperature
Voltage
Conforming to IEC 1812-1
Typical
Typical under load
Typical
ms
ms
ms
0.05 % / C
0.2 % / V
10 % at 25 C
30
100
100
Typical
ms
> 10
Supply characteristics
Mutivoltage supply
Frequency
Operating range
On-load factor
Maximum power
consumption
Hz
Depending
on model
$ 24 V
$ 240 V
" 240 V
W
W
VA
Output characteristics
Output type
Breaking capacity
Maximum breaking current
Minimum breaking current
Maximum switching voltage
Electrical life
Mechanical life
Dielectric strength
Impulse voltage
A
mA
V
kV
kV
Display characteristics
State indication by 2 LEDs
Green
Yellow
On-delay relay
Input characteristics
Input type
References :
pages 3/18 and 3/19
3/16
Dimensions :
page 3/18
Schemes :
page 3/19
Characteristics (continued)
General characteristics
Conforming to standards
Product certifications
c UL us, CSA,
GL except RE 88 865 503
Temperature limits
Operation
Storage
C
C
- 20+ 60
- 30+ 60
Creepage distance
and clearance
Degree of protection
conforming to IEC 529
kV
4 kV/3
Terminal block
Enclosure
Front panel
IP 20
IP 40
IP 50
Vibration resistance
f = 1055 Hz
A = 0.35 mm
Relative humidity
without condensation
Electromagnetic
compatibility
93 %
Immunity to electrostatic
discharge,
conforming to IEC 1000-42
Immunity to electromagnetic
fields, conforming to
ENV 50140/204
(IEC 1000-4-3)
Immunity to fast transients in
bursts
conforming to IEC 1000-4-4
Immunity to surges on the power
supply, conforming to
IEC 1000-4-5
Immunity to radio frequency
interference in common mode
conforming to ENV 50141
(IEC 1000-4-6)
Immunity to voltage dips
and breaks conforming to
IEC 1000-4-11
30 % / 10 ms
60 % / 100 ms
95 % / 5 s
Class B
References :
pages 3/18 and 3/19
mm
35
mm2
mm2
2 x 2.5
2 x 1.5
mm2
mm2
1.5
2.5
Self-extinguishing
Dimensions :
page 3/18
Schemes :
page 3/19
3/17
References,
dimensions,
schemes
Function diagrams
Function A
Function H
Delay on energisation
Timing on energisation
R
T1 T2
Function B
Function Li
Asymmetrical recycler
Pulse start
Function L
Function Di
Asymmetrical recycler
Start after pause
Flashing relay
Pulse start
R
T1 T2
T T
Connection
Screw terminals
Spring terminals
Functions
Timing ranges
7 ranges
Selectable interswitching time
Rated current
Voltages
$24 V / "24240 V
"/$12 V
"/$12240 V
"230 / 380 V
Weight (kg)
561172
561172
561171
References
/
/
Multifunction
Dual function
A - At - B - C - H - Ht - Di - D
A - At
Ac - Bw
1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
Single function
B
8A
RE 88 865 105
0.090
8A
RE 88 865 125
0.090
8A
RE 88 865 115
0.090
63
22,5
3,5
57
78
A1 15 Y1
18 16 A2
95
5
Characteristics :
pages 3/16 and 3/17
3/18
Schemes :
page 3/19
Function C
Function At
Function Ht
Function D
Function Bw
Off-delay
Timing on energisation
with memory
Flashing relay
Start after pause
t1
Function Ac
t2
T = t1+t2
t1
t2
T = t1+t2
Function Q
Star-delta starting
R
T
Dual function
H - Ht
Dual function
Li - L
8A
RE 88 865 135
0.090
8A
RE 88 865 145
0.090
8A
RE 88 865 155
0.090
561171
561172
561172
561172
Single function
C
561174
561172
Ti
561173
C
T T
Single function
Q
Single function
Q
Multifunction
A - At - B - C - H Ht - Di - D - Ac - Bw
/
Multifunction
A - At - B - C - H Ht - Di - D - Ac - Bw
0.090
RE 88 865 176
0.090
8A
RE 88 865 103
0.090
8A
RE 88 865 503
0.090
Connection schemes
All functions except L and Li
Functions L and Li
Function Q
U
+
U
+
+
(1)
A1
Y1
A1
15
R
Y1
15
R
16 15
16 18
15
R
A2
A2
A2
A1
28 18
Characteristics :
pages 3/16 and 3/17
Dimensions :
page 3/18
3/19
Characteristics
Timing characteristics
Repeat accuracy
(with constant parameters)
Drift
Full scale setting accuracy
Minimum duration of control
impulse
Maximum reset time
by de-energisation
Immunity time
to microbreaks
0.5 %
Temperature
Voltage
Conforming to IEC 1812-1
Typical
Typical under load
Typical
ms
ms
ms
0.05 % / C
0.2 % / V
10 % at 25 C
30
100
100
Typical
ms
> 10
Supply characteristics
Multivoltage supply
Frequency
Operating range
On-load factor
Maximum power
consumption
Hz
Depending
on model
$ 24 V
$ 240 V
" 240 V
W
W
VA
Output characteristics
Output type
Breaking capacity
Maximum breaking current
Minimum breaking current
Maximum switching voltage
Electrical life
Mechanical life
Dielectric strength
Impulse voltage
A
mA
V
kV
kV
Display characteristics
State indication by 2 LEDs
Green
Yellow
On-delay relay
Input characteristics
Input type
References :
pages 3/22 and 3/23
3/20
Dimensions :
page 3/22
Schemes :
page 3/23
Characteristics (continued)
General characteristics
Conforming to standards
Product certifications
Temperature limits
Operation
Storage
C
C
c UL us, CSA
GL except RE 88 865 265
- 20+ 60
- 30+ 60
Creepage distance
and clearance
Degree of protection
conforming to IEC 529
kV
4 kV/3
Terminal block
Enclosure
Front panel
IP 20
IP 40
IP 50 except RE 88 865 265
Vibration resistance
f = 1055 Hz
A = 0.35 mm
Relative humidity
without condensation
Electromagnetic
compatibility
93 %
Immunity to electrostatic
discharge,
conforming to IEC 1000-42
Immunity to electromagnetic
fields, conforming to
ENV 50140/204
(IEC 1000-4-3)
Immunity to fast transients in
bursts conforming to
IEC 1000-4-4
Immunity to surges on the power
supply, conforming to
IEC 1000-4-5
Immunity to radio frequency
interference in common mode
conforming to ENV 50141
(IEC 1000-4-6)
Immunity to voltage dips and
breaks, conforming to
IEC 1000-4-11
30 % / 10 ms
60 % / 100 ms >
95 % / 5 s
Class B
mm
35
mm2
2 x 2.5
2 x 1.5
mm2
Enclosure material
Self-extinguishing
References :
pages 3/22 and 3/23
Dimensions :
page 3/22
90
Schemes :
page 3/23
3/21
References,
dimensions,
schemes
Function diagrams
Function A
Function C
Delay on energisation,
2 timed contacts or
2 timed contacts, 1 of which
convertible to instantaneous
R1/R2
R1/R2
R2 INST
R1/R2
R2 inst.
Function B
Flashing relay
Pulse start
2 timed contacts or
2 timed contacts, 1 of which
convertible to instantaneous
R1/R2
T T
R1/R2
t1
R2 Inst.
t2
R2 Inst.
R2 Inst.
T = t1+t2
Screw terminals
Timing ranges
7 ranges
4 ranges
Relay output
Rated current
Voltages
$24 V / "24240 V
"/$12 V
Weight (kg)
561176
561175
References
Connection
Functions
/
Multifunction
A - At - B - C - H - Ht - Di - D - Ac - Bw
1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
0.090
/
Dual function
A - At
2 timed contacts
8A
RE 88 865 215
0.090
63
22,5
3,5
57
78
A1 15 Y1
18
95
5
Characteristics :
pages 3/20 and 3/21
3/22
Schemes :
page 3/23
Function Di
R1/R2
R2 Inst.
Function Ht
Function Ac
Off-delay
2 timed contacts or
2 timed contacts, 1 of which
convertible to instantaneous
16 A2
Function K
Function At
Delay on de-energisation
True off-delay
(without auxiliary supply)
2 timed contacts
Function H
Timing on energisation
with memory
2 timed contacts or
2 timed contacts, 1 of which
convertible to instantaneous
U
R1/R2
T
Function D
Timing on energisation
2 timed contacts or
2 timed contacts, 1 of which
convertible to instantaneous
R1/R2
Flashing relay
Start after pause
2 timed contacts or
2 timed contacts, 1 of which
convertible to instantaneous
t1
R1/R2
T T
R2 Inst.
R2 Inst.
t2
U
T
R1/R2
Function Bw
Pulse output (adjustable)
2 timed contacts or
2 timed contacts, 1 of which
convertible to instantaneous
R1/R2
T
R2 Inst.
R2 Inst.
T = t1+t2
561176
561176
/
Single function
K
0.090
/
Multifunction
A - At - B - C - H - Ht - Di - D - Ac - Bw
1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
RE 88 865 303
0.090
Connection schemes
All functions except K
Function K
A1
Y1
15
R1
15
A1
25/21
R2
A2
25
R1
R2
16 18
26 28
A2
16 18
Characteristics :
pages 3/20 and 3/21
26/22 28/24
Dimensions :
page 3/22
3/23
Characteristics
Presentation
560872
The RE7 range of relays, with only 23 references, covers all timing applications.
These relays offer multi-range timing from 50 ms to 300 h.
They are multivoltage.
Three models combine several different functions: multifunction relays.
These products have a transparent, hinged flap on their front face to avoid any
accidental alteration of the settings. This flap can be directly sealed.
Environment
Conforming to standards
Product certifications
& marking
Ambient air temperature
around the device
Permissible relative
humidity range
Vibration resistance
Shock resistance
Degree of protection
Storage
Operation
Conforming to IEC 60721-3-3
Conforming to IEC 6068-2-6,
10 to 55 Hz
Conforming to IEC 6068-2-27
Casing
Terminals
Conforming to IEC 60664-1
Conforming to IEC 60664-1
Conforming to IEC
Conforming to CSA
Degree of pollution
Overvoltage category
Rated insulation voltage
Between contact circuit and
power supply or between contact
circuit and control inputs
Test voltage for
Dielectric test
insulation tests
Shock wave
Voltage limits
Power supply circuit
Frequency limits
Power supply circuit
Disconnection value
Power supply circuit
Mounting position
In relation to normal
without derating
vertical mounting plane
Cabling
Flexible cable without cable end
Maximum c.s.a.
Flexible cable with cable end
Tightening torque
C
C
V
V
kV
kV
Hz
mm2
mm2
N.m
15 gn - 11 ms
IP 50
IP 20
3
III
250
300
2.5
4.8
0.851.1 Uc
50/60 5 %
> 0.1 Uc
Any position
2 x 2.5
2 x 1.5
0.61.1
Consumption
Average consumption
References :
pages 3/26 to 3/29
3/24
" 50/60 Hz
24 V
48 V
110 V
VA
0.7
1.6
1.8
RE7-//11BU
RE7-//12BU and RE7-//13BU VA
1.2
2
2.8
RE7-////MW (1)
VA
2
2.5
3.2
(1) RE7-RB//MW: current peak on energisation = 1 A / 30 ms.
240 V
8.5
12.5
6
W
W
W
$
24 V
0.5
0.8
2
48 V
1.2
1.6
1
110 V
3.2
240 V
Characteristics (continued)
Timing characteristics
Setting accuracy
Repeat accuracy
Influence of voltage
Influence of temperature
Immunity to microbreaks
Minimum control pulse
Reset time
10 %
0.2 %
< 0.2 %
< 0.07 %/C
3
20 (except RE7-RB1/MW: 1 s)
50
7 250
20
8 (except RE7-RB//MW: 5 A)
24 V
115 V
3
3
2
0.2
12 V/10 mA
90/10 nickel silver
(except RE7-RB//MU: gold flashed silver alloy)
V
A
A
A
250 V
3
0.1
Applicable to inputs
Y1Z2, X1Z2, X2Z2
Switching current
Maximum distance
Compatibility
mA
m
<1
50
3/4-wire PNP and NPN Telemecanique sensors or other sensors without an internal
load
Linear at 20 %
47 20 %
0.2
25 by shielded cable: shielding linked to terminal Z2
Curve 2
Reduction factor k for inductive loads (applies to
values taken from durability curve 1)
1
0,9
d.c. load
Load limit curve
Voltage in V
10
60
k
W
m
Reduction factor k
a.c. load
Curve 1
Electrical durability of contacts on resistive load
in millions of operating cycles
0,8
0,7
300
200
100
0,6
50
40
30
0,5
0,1
2
1
0,4
20
A
0,01
0,3
0
5
6
7
8
Current broken in A
0,8
10
0,1
A RE7-RB//MW
A
1
2
3
Example:
An LC1-F185 contactor supplied with 115 V/50 Hz for a consumption of 55 VA or a current consumption
equal to 0.1 A and cos = 0.3.
For 0.1 A, curve 1 indicates a durability of approximately 1.5 million operating cycles.
As the load is inductive, it is necessary to apply a reduction coefficient k to this number of cycles as indicated
by curve 2.
A
0,2
0,5
10 20
Current in A
RE7-RB//MW
L/R = 20 ms
L/R with load protection diode
Resistive load
RE7
References :
pages 3/26 to 3/29
3/25
Functions,
references,
schemes
Function diagrams
Function A
Function Wt
Function At
Delay on energisation
Supply
Supply
Supply
Partial
(Y1Z2)
stop
Partial
(X1Z2)
stop
C/O
15/18 (25/28)
15/16 (25/26)
t1
C/O
t3
t2
15/18
15/16
C/O
15/18
15/16
Function H
Function Hi
Pulse-on energisation
Start on energisation
t = t1 + t2 + t3
Function Ht
Supply
Supply
Supply
C/O
Start
15/18 (25/28)
15/16 (25/26)
Partial
stop
Y1Z2
X1Z2
t1
C/O
15/18
15/16
C/O
t2
15/18
15/16
t = t1 + t2 + t3
Functions
Timing ranges
560874
560874
560873
560873
References
References
A
0.05 s...300 h
10 ranges
/
/
RE7 TL11BU
A, Wt, At
0.05 s...300 h
10 ranges
/
/
/
RE7 TM11BU
Ac
0.05 s...300 h
10 ranges
/
/
/
RE7 MA11BU
Ae, Af
0.05 s...300 h
10 ranges
/
/
/
RE7 MV11BU
Weight (kg)
0.150
0.150
0.150
0.150
Voltages
$or " 24 V
"110240 V
" or $ 4248 V
$or " 24240 V
Screw fixing
89,5
82
Characteristics :
pages 3/24 and 3/25
3/26
Schemes :
pages 3/30 and 3/31
22,5
78
6
78
80
t3
Function Ac
Function Ae
Function Af
Function K
Function Hf
Off-delay
Supply
Supply
Supply
External
control
C/O
Partial
stop
> 1 s (1)
Start
Supply
Y1Z2
Start
C/O
Y1Z2
15/18
15/16
t1
C/O
15/18 (25/28)
15/16 (25/26)
X1Z2
Partial stop
time delay
t1
ts t2 t3
ts
t3
t4
15/18 (25/28)
15/16 (25/26)
tr
Function L
t1 ts t2
Function Li
Function Lt
Supply
Supply
Supply
Supply
C/O
C/O
C/O
15/18 (25/28)
15/16 (25/26)
15/18
15/16
t1 + t2 = ta
t3 + t4 = tr
C/O
X1Z2
C/O
C/O
ta
t4
Function D
t2
Y1
tr
15/18 (25/28)
15/16 (25/26)
15/18 (25/28)
15/16 (25/26)
ta
ta
tr
Partial
stop
X1Z2
t1 ts t2 t3 ts t4
K
0.05 s10 min
7 ranges
/
RE7 RB11MW
0.150
Hf
0.05 s...300 h
10 ranges
/
/
/
RE7 RA11BU
RE7 RM11BU
low level contact
0.150
560877
560877
560876
560876
560875
560875
(1) If the device has been stored, de-energised, for more than a month, it must be energised for about 15 seconds in order to activate it. Subsequently, it only takes
1 second to start the time delay. % If this time is not complied with, the relay remains energised indefinitely.
H
0.05 s...300 h
10 ranges
/
/
RE7 PE11BU
Hi, Ht
0.05 s...300 h
10 ranges
/
/
/
RE7 PM11BU
D
0.05 s...300 h
10 ranges
/
/
RE7 CL11BU
L, Li, Lt
0.05 s...300 h
10 ranges
/
/
/
RE7 CV11BU
0.150
0.150
0.150
0.150
Connection schemes
A2
Characteristics :
pages 3/24 and 3/25
A2
X1
18
Z2
A2
15
B1
B2
X1
18
Y1
16
18
16
15
B1
B2
A1
15
18
16
Y1
16
A1
Z1
A2
B1
B2
B1
B2
A1
15
A2
16
16
18
15
A1
B1
A2
15
A1
16
18
18
A1
Z1
Z2
A2
A1
Z1
15
Z3
B1
B2
X1
18
15
15
16
A2
B1
RE7 MA11BU
RE7 MV11BU
RE7 CV11BU
18
16
A2
18
B1
A1
15
B1
A1
16
15
18
RE7 CL11BU
18
RE7 PE11BU
A1
16
A2
15
A2
15
16
18
16
A2
18
A1
B1
B2
A1
B1
A1
15
B1
A1
RE7 RB11MW
A2
RE7 TL11BU
X2
16
Dimensions :
page 3/26
Z2
A2
Schemes :
pages 3/30 and 3/31
3/27
Functions,
references,
schemes
Function diagrams
Function A
Function Ac
Start on energisation
Function C
Supply
Supply
Supply
C/O
Start
Start
Y1Z2
15/18 (25/28)
15/16 (25/26)
C/O
15/18 (25/28)
15/16 (25/26)
C/O
ta
15/18
15/16
tr
Function K
Off-delay
> 1 s (1)
Supply
C/O
15/18 (25/28)
15/16 (25/26)
(1) If the device has been stored, de-energised, for more than a month, it must be energised for
about 15 seconds in order to activate it. Subsequently, it only takes 1 second to start the time
delay. % If this time is not complied with, the relay remains energised indefinitely.
References
A
0.05 s...300 h
10 ranges
/
/
/
RE7 TP13BU
Weight (kg)
0.150
Voltages
$or " 24 V
"110240 V
" or $ 4248 V
$or " 24240 V
Ac
0.05 s...300 h
10 ranges
/
/
/
RE7 MA13BU
symmetrical
0.150
560904
560903
560902
Functions
Timing ranges
560904
References
C
0.05 s...300 h
10 ranges
/
/
/
RE7 RL13BU
low level contact
0.150
K
0.05 s10 min
7 ranges
/
RE7 RB13MW
0.150
Screw fixing
89,5
82
Characteristics :
pages 3/24 and 3/25
3/28
Schemes :
pages 3/30 and 3/31
22,5
78
6
78
80
Function H
Function Hi
Pulse-on energisation
Start on energisation
Function Qt
Function Qg
Function D
Supply
Supply
Supply
Supply
Start
C/O1 15/18
C/O1
Supply
C/O
15/18 (25/28)
15/16 (25/26)
C/O2
C/O
C/O
17/18
15/16
Y1Z2
t
15/18
15/16
C/O2
25/28
25/26
15/18 (25/28)
15/16 (25/26)
17/28
star
K1
delta
K3
K1
star
K3
delta
50 ms
50 ms
Function Di
Symmetrical flasher start
with output in operating
position
Supply
C/O
560908
560908
560907
560906
560907
560905
560905
H
0.05 s...300 h
10 ranges
/
/
/
RE7 PP13BU
Hi
0.05 s...300 h
10 ranges
/
/
/
RE7 PD13BU
D
0.05 s...300 h
10 ranges
/
/
/
RE7 CP13BU
Qt
0.05 s...300 h
10 ranges
/
/
/
RE7 YA12BU
Qg
0.05 s...300 h
10 ranges
/
/
/
RE7 YR12BU
A, C, H, Hi, D, Di
0.05 s...300 h
10 ranges
/
/
/
RE7 ML11BU
/
RE7 MY13BU
RE7 MY13MW
0.150
0.150
0.150
0.150
0.150
0.150
0.150
0.150
Connection schemes
Z2
A2
26
16
Z2
A2
28 (24)
18
Z2
A2
28 (24)
18
15
25
(21)
18
16
B1
B2
26
(22)
28
(24)
15
25 (21)
B1
B2
A1
25
(21)
26 (22)
16
A1
Z1
A2
15
18
16
B1
B2
26
(22)
28
(24)
15
25 (21)
B1
B2
A1
A1
Y1
A2
28
26
18
16
25
B1
B2
15
B1
B2
A1
28
18
26 (22)
16
Z2
A2
28 (24)
18
25
(21)
26
(22)
28
(24)
Y1
X1
15
15
25 (21)
18
25
(21)
26
(22)
28
(24)
Z2
A2
A1
Z1
16
15
26 (22)
16
Dimensions :
page 3/29
B1
Y1
18
16
A1
28 (24)
18
15
25
RE7 PP13BU
RE7 CP13BU
RE7 MY13MW
15
25 (21)
A2
28
B1
17
Characteristics :
pages 3/24 and 3/25
26
18
26
16
A1
Z1
A2
25
28
Z2
A2
RE7 MY13BU
16
A2
28
18
26
16
A1
B1
B2
B1
B2
A1
A1
28
18
A2
17
17
RE7 YR
15
A1
A2
Z2
A2
A1
15
25
18
25
(21)
26 (22)
16
RE7 YA
26
15
18
16
A2
28 (24)
18
A1
Z1
B1
B2
26
(22)
28
(24)
15
25 (21)
B1
B2
A1
A1
Z1
RE7 RB13MW
16
RE7 TP13BU
26 (22)
16
Z2
A2
Schemes :
pages 3/30 and 3/31
3/29
Schemes
Z2
B1
B2
A1 X1
A2
Z2
B1
A1
A1
A2
B2
Y1
A2
B1 Y1
Y1
A2
A2
B2
B3
A2
B1
B2
A1 X2
A2
Z2
RE7 MV
RE7 CV
Connection of potentiometers to
asymmetrical timing relays
Connection of potentiometers
A2
Z3
Z1
Z2
(4)
(5)
A2
Z3
Z1
Z2
No galvanic isolation between supply terminals A1, A2, B1, B2 and control inputs X1, Y1, Z1, Z2.
(1) " 110240 V except RE7 MY13MW :724240 V
(2) 7 1248 V
(3) 7 24 V
(4) Adjustment of the On-delay period
(5) Adjustment of the Off-delay period
(6) Start during the On-delay period : X2, Z2 linked. Start during the Off-delay period : X2, Z2 not linked
(7) Off-delay adjustment (tr) (contact 15/16 closed)
(8) On-delay adjustment (ta) (contact 15/18 closed)
Characteristics :
pages 3/24 and 3/25
3/30
References :
pages 3/26 to 3/29
(7)
(6)
Connection precautions
(8)
X1 or Y1 or Z1
Supply
A2
B1
RE7 CV
Selection of starting phase
(1)
(2)
A1
A2
(3)
RE7 PE
Start on energisation
(1)
(3)
(3)
RE7 PP
Start on energisation
Z1
Z2
Z2
B2
A1 X1
A2
RE7 RA
Start by external control
B1
B2
(3)
A1 Y1
A2
(2)
B2
(1)
(3)
(2)
B1
A2
(3)
A1
(1)
(3)
B2
RE7 RB
Start on de-energisation
(1)
(2)
(2)
(1)
B1
(2)
Start on energisation
(1)
A2
Z2
Schemes (continued)
A2
A2
Terminal block
B1
B2
28
26
18
13
Z2
A2
A1
14
K1
14
22 28
K3
A2
K1
26
16
K2
A2
K1T
A2
W2
A1 21
K1
A1
U2
A2
U1
M1
3
A1 21
V2
W1
13
17
17
K3
K2
22 18
K1T
F2
17
17
B1
B2
A1
A2
53
5
6
14
54
3
4
13 22
28
18
K2
S2
6
5
4
3
2
1
K1
K3
K2
S1
21 96
F2
17
95
A1
16
L3
L2
L1
Control schemes
Star-delta function with contact for switching to star connection Q
F3
V1
18
K3
Power scheme
RE7 YR12BU
16
A2
14
22 25
A1
A1
K2
K1T
A2
K1
W2
U1
A1 21
K1
U2
A2
M1
3
Z2
A2
28 13
14
16
V1
A1 21
K3
V2
W1
26
16
K1T
22 15
K1T
F2
28
18
K2
14 K1 13
15
B1
B2
A1
21 96
13 22
5
6
S2
6
5
4
3
2
1
K1
K3
K2
S1
B1
B2
25
15
25
F2
28
95
A1
26
F3
L3
L2
L1
Power scheme
RE7 YA12BU
No galvanic isolation between supply terminals A1, A2, B1, B2 and supply terminal Z2.
This terminal must therefore never be used (factory setting).
Control of several relays with a single external control contact
Connection of a Telemecanique 3-wire NPN or PNP sensor
A1,B1 or B12
Y1 or X1
Z2
A2
A1,B1 or B12
Y1 or X1
Z2
A2
A1,B1 or B12
Y1 or X1
Z2
A2
Supply
Supply
+
A1,B1 or B12
Y1 or X1
A2 Z2
BN
BK
BU
NPN
PNP
It is advisable to follow the recommended wiring schemes detailed above and on previous pages. However, the connections below are possible if the restrictions
given are taken into account.
Connection of an external control contact without using terminal Z2:
Connection of a Telemecanique 3-wire NPN or PNP sensor without using
terminal Z2:
- possible on all RE7 relays with external control option except RE7 RA11BU,
- only possible on relay RE7////BU,
- d.c. supply only.
- d.c. supply only.
+
A1,B1 or B12
Y1 or X1
Z2
A2
Characteristics :
pages 3/24 and 3/25
A1,B1 or B12
Y1 or X1
A2
Z2
24
or
48 V
+
B1B2
A2
Y1
Z2
BN
BK
BU
NPN
24
or
48 V
B1B2
A2
Y1
Z2
BN
BK
BU
PNP
References :
pages 3/26 to 3/29
3/31
Characteristics
Presentation
560953
The RE8 range of relays is designed for simple and repetitive applications, providing
basic functions.
Each relay comprises:
- a single timing range,
- a C/O output relay.
These products have a transparent, hinged flap on their front face to avoid any
accidental alteration of the settings. This flap can be directly sealed.
Environment
Conforming to standards
Product certifications
&marking
Ambient air temperature
around the device
Permissible relative
humidity range
Vibration resistance
Shock resistance
Degree of protection
Degree of pollution
Overvoltage category
Rated insulation voltage
Test voltage for
insulation tests
Voltage limits
Frequency limits
Disconnection value
Mounting position
without derating
Connection
maximum c.s.a.
Storage
Operation
Conforming to IEC 60721-3-3
Conforming to IEC 6068-2-6,
10 to 55 Hz
Conforming to IEC 6068-2-27
Casing
Terminals
Conforming to IEC 60664-1
Conforming to IEC 60664-1
Conforming to IEC
Conforming to CSA
Dielectric test
Shock wave
Power supply circuit
Power supply circuit
Power supply circuit
In relation to normal
vertical mounting plane
Flexible cable without cable end
Flexible cable with cable end
Tightening torque
C
C
V
V
kV
kV
Hz
mm2
mm2
N.m
15 gn - 11 ms
IP 50
IP 20
3
III
250
300
2.5
4.8
0.91.1 Uc
50/60 5 %
> 0.1 Uc
Any position
2 x 2.5
2 x 1.5
0.61.1
"
24 V
0.7
0.9
0.9
Consumption
Consumption
References :
pages 3/34 to 3/37
3/32
Dimensions :
pages 3/34 and 3/36
VA
VA
VA
Schemes :
page 3/35
110 V
1.8
2.5
2.5
240 V
8.5
13
13
380 V
415 V
W
W
W
$
24 V
0.5
0.5
0.7
Characteristics (continued)
Timing characteristics
Setting accuracy
Repeat accuracy
Influence of voltage
Influence of temperature
Immunity to microbreaks
Minimum control pulse
Reset time
20 %
<1 %
< 2.5 %
< 0.2 %/C
3
26 (except RE8-YG: 60)
50
V
A
A
A
7 250
20
8
24 V
3
2
12 V/10 mA
90/10 nickel silver
115 V
3
0.2
250 V
3
0.1
10
Supply voltage
< 10
50
2-wire sensors $ with leakage current < 1 mA
Curve 2
Reduction factor k for inductive loads (applies to
values taken from durability curve 1)
Reduction factor k
a.c. load
Curve 1
Electrical durability of contacts on resistive load
in millions of operating cycles
mA
m
d.c. load
Load limit curve
Voltage in V
1
0,9
0,8
0,7
300
200
100
0,6
50
40
30
0,5
0,1
2
1
0,4
20
A
0,01
0,3
0
5
6
7
8
Current broken in A
0,8
0,6 0,5 0,4
0,3
Power factor on breaking (cos )
10
0,1
0,2
A RE8-RB//BUTQ
A
1
2
3
A
0,2
0,5
10 20
Current in A
RE8-RB//BUTQ
L/R = 20 ms
L/R with load protection diode
Resistive load
Example:
An LC1-F185 contactor supplied with 115 V/50 Hz for a consumption of 55 VA or a current consumption
equal to 0.1 A and cos = 0.3.
For 0.1 A, curve 1 indicates a durability of approximately 1.5 million operating cycles.
As the load is inductive, it is necessary to apply a reduction coefficient k to this number of cycles as indicated
by curve 2.
For cos = 0.3: k = 0.6
The electrical durability therefore becomes:
1.5 106 operating cycles x 0.6 = 900 000 operating cycles.
References :
pages 3/34 to 3/37
Dimensions :
pages 3/34 and 3/36
+
RE8
Schemes :
page 3/35
3/33
Functions,
references,
schemes
Function diagrams
Function A
Function C
Start on energisation
Supply
Supply
C/O
Start
15/18
15/16
C/O
15/18
15/16
560954
Functions
Voltages
Timing ranges
$or " 24 V
"110240 V
"380415 V
0.05 s0.5 s
0.1 s3 s
0.1 s10 s
0.3 s30 s
3 s300 s
20 s30 min
Weight (kg)
560954
A
/
/
RE8 TA61BUTQ
RE8 TA11BUTQ
RE8 TA31BUTQ
RE8 TA21BUTQ
RE8 TA41BUTQ
0.110
C
/
RE8 RA11BTQ
RE8 RA31BTQ
RE8 RA21BTQ
0.110
RE8 RA11FUTQ
RE8 RA31FUTQ
RE8 RA21FUTQ
RE8 RA41FUTQ
0.110
Dimensions
Dimensions
Rail mounting
Screw fixing
89,5
82
Characteristics :
pages 3/32 and 3/33
3/34
Schemes :
page 3/35
22,5
78
6
78
80
Function K
Function D
Off-delay
Symmetrical
Supply
Supply
C/O
C/O
15/18
15/16
560954
560954
> 80 ms
15/18
15/16
K
/
/
RE8 RB51BUTQ
RE8 RB11BUTQ
RE8 RB31BUTQ
0.110
D
/
/
RE8 CL11BUTQ
0.110
Schemes
Connection schemes
15
RE8 RA
15
B1
start
B1
18
16
15
16
RE8 TA, CL
A2
A1
Y1
A2
A1
18
16
15
B1
A1
RE8 RB
A1
B1
15
A2
15
A1
B1
A1
18
RE8 TA, CL
A2
A1
18
16
A2
18
16
18
A2
16
A1 Y1
A2
A2
+
A1
A2
Y1
A1
A2
Y1
A1
Y1
If
A1
A2
Y1
A2
The external control contact C may be an electronic control device, for example
a 2-wire sensor. In this case A1-A2 = $ 24 V and the control device can only
control up to a maximum of 4 relays.
Characteristics :
pages 3/32 and 3/33
Dimensions :
page 3/34
3/35
Function,
references,
schemes
(continued)
Function diagrams
Function H
Function W
Pulse-on energisation
Supply
Supply
C/O
15/18
15/16
Start
Y1A1
C/O
15/18
15/16
560968
560968
Functions
Voltages
$or " 24 V
"110240 V
"380415 V
0.05 s0.5 s
0.1 s3 s
0.1 s10 s
0.3 s30 s
3 s300 s
20 s30 min
Timing ranges
Weight (kg)
H
/
/
RE8 PE11BUTQ
RE8 PE31BUTQ
RE8 PE21BUTQ
0.110
W
/
RE8 PD11BTQ
RE8 PD31BTQ
RE8 PD21BTQ
0.110
RE8 PD11FUTQ
RE8 PD31FUTQ
RE8 PD21FUTQ
0.110
Dimensions, schemes
Dimensions
Rail mounting
Screw fixing
78
78
80
22,5
89,5
82
3/36
Schemes :
page 3/37
A2
18
16
A2
15
18
B1
16
18
16
15
B1
A2
A1
A1
A1
25
28
25
28
A2
15
16
15
15
A1
RE8 YG
16
B1
A2
15
18
15
16
A1
Characteristics :
pages 3/32 and 3/33
16
A1
16
18
Y1
RE8 YA
B1
A2
A2
15
16
15
A1
A1
18
16
A1
18
B1
RE8 PT
A2
15
B1
A2
A1
RE8 PD
18
RE8 PE
A2
Function He
Function Qc
Function Qe
Supply
Supply
Supply
C/O
15/18
15/16
15/18
15/16
Star
<t
C/O
15/16
N/O
25/28
t
Delta
> 80 ms
50 ms
560969
560968
560969
80 ms
He
/
/
RE8 PT01BUTQ
0.110
Qc
/
/
RE8 YG11BUTQ
RE8 YG31BUTQ
RE8 YG21BUTQ
0.110
Qe
/
RE8 YA32BTQ
0.110
RE8 YA32FUTQ
0.110
RE8 YA32QTQ
0.110
RE8 PD
+
start
B1
A1 Y1
A2
A2
A1
RE8 YG
RE8 YA
L3
L2
L1
Q1
25
15
A1
A1
A1
A2
A2
(1)
A2
A1
A2
28
16
A1
A2
A1
A1
(1)
15
A2
A2
W2
V2
U2
Rth
A1
16
A2
W1
V1
U1
KM1
KM3
KM2
Dimensions :
page 3/36
3/37
Characteristics
Timing characteristics
Repeat accuracy
(with constant parameters)
Drift
Full scale setting accuracy
Minimum duration of control
impulse
Maximum reset time
by de-energisation
Immunity time
to microbreaks
0.5 %
Temperature
Voltage
Conforming to IEC 1812-1
Typical
Typical under load
Typical
ms
ms
ms
0.05 % / C
0.2 % / V
10 % at 25 C
30
100
100
Typical
ms
> 10
Supply characteristics
Multivoltage supply
Frequency
Operating range
On-load factor
Maximum power
consumption
Hz
Depending on
model
$ 24 V
$ 240 V
" 240 V
W
W
VA
Output characteristics
Output type
Breaking capacity
Maximum breaking current
Minimum breaking current
Maximum switching voltage
Electrical life
Mechanical life
Dielectric strength
Impulse voltage
A
mA
V
kV
kV
Display characteristics
State indication by 1 LED
Green
Input characteristics
Input type
References :
pages 3/40 and 3/41
3/38
Dimensions :
page 3/40
Schemes :
page 3/41
Characteristics (continued)
General characteristics
Conforming to standards
Product certifications
c UR us, CSA, GL
Temperature limits
Operation
Storage
C
C
- 20+ 60
- 30+ 60
Creepage distance
and clearance
Degree of protection
conforming to IEC 529
kV
4 kV/3
Terminal block
Enclosure
Front panel
Vibration resistance
Relative humidity
without condensation
Electromagnetic
compatibility
f = 1055 Hz
A = 0.35 mm
Conforming to IEC 68-2-3
93 %
Immunity to electrostatic
discharge, conforming to
IEC 1000-42
Immunity to electromagnetic
fields, conforming to
ENV 50140/204
(IEC 1000-4-3)
Immunity to fast transients
in bursts
conforming to IEC 1000-4-4
Immunity to surges on the power
supply, conforming to
IEC 1000-4-5
Immunity to radio frequency
interference in common mode
conforming to ENV 50141
(IEC 1000-4-6)
Immunity to voltage dips and
breaks conforming to
IEC 1000-4-11
Plug-in socket
Enclosure material
References :
pages 3/40 and 3/41
IP 20
IP 40
IP 50
30 % / 10 ms
60 % / 100 ms >
95 % / 5 s
Class B
8-pin
Self-extinguishing
Dimensions :
page 3/40
Schemes :
page 3/41
3/39
References,
dimensions,
schemes
Function diagrams
Function A
Function C
Delay on energisation
1 contact
Off-delay
1 timed contact
2 timed contacts
R1/R2
T
Function Di
Function B
Function Ht
Flashing relay
Pulse start
3
T T
R
t1
t2
T = t1+t2
Connection
Functions
Plug-in sub-base
Timing ranges
Relay output
Rated current
Voltages
7 ranges
Weight (kg)
Socket (1)
$24 V / "24240 V
"/$12 V
"/$12240 V
8-pin
Weight (kg)
561178
561178
561177
References
/
/
Multifunction
Single function
A - At - B - C - H - Ht - Di - D
A
Ac - Bw
1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
1 timed contact
2 timed contacts
8A
8A
RE 88 867 105
RE 88 867 215
0.080
0.080
RUZ 1D
RUZ 1D
0.067
0.067
(1) These products are sold in packs of 10
/
Single function
C
1 timed contact
8A
RE 88 867 135
0.080
RUZ 1D
0.067
74,5
35
12,5
45
3,5
Characteristics :
pages 3/38 and 3/39
3/40
Schemes :
page 3/41
Function L
Function D
Function At
Function H
Function Li
Asymmetrical recycler
Start after pause
Flashing relay
Start after pause
Timing on energisation
with memory
Timing on energisation
Asymmetrical recycler
Pulse start
R
T1 T2
T T
t1
Function Ac
R
T1 T2
R
t2
T = t1+t2
Function Bw
U
U
C
R
T
561178
561179
561178
/
Dual function
Li - L
/
Multifunction
A - At - B - C - H - Ht - Di - D - Ac - Bw
/
Multifunction
A - At - B - C - H - Ht - Di - D - Ac - Bw
0.080
RUZ 1D
0.067
1 timed contact
8A
RE 88 867 100
0.080
RUZ 1D
0.067
1 timed contact
8A
RE 88 867 103
0.080
RUZ 1D
0.067
Functions L and Li
Connection schemes
Timing relays with 1 relay output
All functions except L and Li
U
4
3
2
4
6
R
1
+
U
3 R1
5
R2 6
7
(1)
R
1
Characteristics :
pages 3/38 and 3/39
Dimensions :
page 3/40
3/41
Characteristics
Timing characteristics
Repeat accuracy
(with constant parameters)
Drift
Full scale setting accuracy
Minimum duration of control
impulse
Maximum reset time
by de-energisation
Immunity time
to microbreaks
0.5 %
Temperature
Voltage
Conforming to IEC 1812-1
Typical
Typical under load
Typical
ms
ms
ms
0.05 % / C
0.2 % / V
10 % at 25 C
30
100
100
Typical
ms
> 10
Supply characteristics
Multivoltage supply
Frequency
Operating range
On-load factor
Maximum power
consumption
Hz
Depending
on model
$ 24 V
$ 240 V
" 240 V
W
W
VA
Output characteristics
Output type
Breaking capacity
Maximum breaking current
Minimum breaking current
Maximum switching voltage
Electrical life
Mechanical life
Dielectric strength
Impulse voltage
A
mA
V
kV
kV
Display characteristics
State indication by 1 LED
Green
Input characteristics
Input type
References :
pages 3/44 and 3/45
3/42
Dimensions :
page 3/44
Schemes :
page 3/45
Characteristics (continued)
General characteristics
Conforming to standards
Product certifications
c UR us, CSA, GL
Temperature limits
Operation
Storage
C
C
- 20+ 60
- 30+ 60
Creepage distance
and clearance
Degree of protection
conforming to IEC 529
kV
4 kV/3
Terminal block
Enclosure
Front panel
IP 20
IP 40
IP 50
Vibration resistance
f = 1055 Hz
A = 0.35 mm
Relative humidity
without condensation
Electromagnetic
compatibility
93 %
Immunity to electrostatic
discharge,
conforming to IEC 1000-42
Immunity to electromagnetic
fields, conforming to
ENV 50140/204
(IEC 1000-4-3)
Immunity to fast transients
in bursts,
conforming to IEC 1000-4-4
Immunity to surges on the power
supply, conforming to
IEC 1000-4-5
Immunity to radio frequency
interference in common mode
conforming to
ENV 50141 (IEC 1000-4-6)
Immunity to voltage dips and
breaks, conforming to
IEC 1000-4-11
Plug-in socket
Enclosure material
References :
pages 3/44 and 3/45
30 % / 10 ms
60 % / 100 ms >
95 % / 5 s
Class B
11-pin
Self-extinguishing
Dimensions :
page 3/44
Schemes :
page 3/45
3/43
References,
dimensions,
schemes
Function diagrams
Function A
Function C
Delay on energisation
2 timed contacts or
2 timed contacts, 1 of which
convertible to instantaneous
Function Ac
Off-delay
2 timed contacts or
2 timed contacts, 1 of which
convertible to instantaneous
R1/R2
R1/R2
R2 inst.
Function B
Flashing relay
Pulse start
2 timed contacts or
2 timed contacts, 1 of which
convertible to instantaneous
R1/R2
T T
R1/R2
t1
R2 Inst.
t2
R2 Inst.
R2 Inst.
T = t1+t2
Plug-in sub-base
Timing ranges
Relay output
7 ranges
Rated current
Voltages
Weight (kg)
Socket (1)
$24 V / "24240 V
"/$12 V
"/$12240 V
11-pin,
Weight (kg)
561181
561180
561181
References
Connection
Functions
/
/
Multifunction
Dual function
A - At - B - C - H - Ht - Di - D
A - At
Ac - Bw
1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
2 timed contacts,
2 timed contacts
1 convertible to instantaneous
8A
8A
RE 88 867 305
RE 88 867 415
0.080
0.080
RUZ 1A
RUZ 1A
0.067
0.067
(1) These products are sold in packs of 10
/
Single function
C
2 timed contacts
8A
RE 88 867 435
0.080
RUZ 1A
0.067
12,5
45
3,5
Characteristics :
pages 3/42 and 3/43
3/44
Dimensions :
page 3/45
Function Di
R1/R2
R2 Inst.
Function Ht
R1/R2
R2 INST
Function Bw
Function At
Function H
Timing on energisation
2 timed contacts or
2 timed contacts, 1 of which
convertible to instantaneous
R1/R2
R1/R2
T
t2
Function L
Asymmetrical recycler
Start after pause
2 timed contacts
U
R1/R2
T
t1
Function D
Flashing relay
Start after pause
2 timed contacts or
2 timed contacts, 1 of which
convertible to instantaneous
R2 Inst.
R1/R2
T T
T1 T2
R2 Inst.
R2 Inst.
T = t1+t2
Function Li
Asymmetrical recycler
Pulse start
2 timed contacts
U
R1/R2
/
Dual function
Li - L
1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
2 timed contacts
8A
RE 88 867 455
0.080
RUZ 1A
0.067
561182
561180
561182
T1 T2
/
Multifunction
A - At - B - C - H - Ht - Di - D - Ac - Bw
/
Multifunction
A - At - B - C - H - Ht - Di - D - Ac - Bw
2 timed contacts,
1 convertible to instantaneous
8A
RE 88 867 300
0.080
RUZ 1A
0.067
2 timed contacts,
1 convertible to instantaneous
8A
RE 88 867 303
0.080
RUZ 1A
0.067
Connection schemes
All functions except L and Li
+
Y1
U
(1)
8
R1
R2
9
10
1
7
8
R1
9
2
R2
Functions L and Li
11
10
1
11
Dimensions :
page 3/44
3/45