Sunteți pe pagina 1din 2

The base modules simply latch

into the DIN rail. Tools are not


needed.
The electronic modules are simply
plugged onto the base modules
Tools are not needed.
The mechanical coding system
ensures secure assignment of
base and electronic modules.

The end plate


With integrated terminating
bracket that is the mechanical
termination of each BL20 station
Ensures vibration-proof mounting
of the station on the mounting rail

End plate

The electronic modules


Incorporate versatile I/O functions
Communicate with the gateway
via the internal module bus

Slice type base


module

The base
modules
For connection
of field wiring

Power feeding
module

Are based on
modular terminal technology
Come as slice or block
versions with tension springs
or screw connections

Block type base


module

Are available with a choice of


2/3/4 and 4 x 2/3 wire
connections

Are independent of the higherlevel fieldbus


May be inserted independently of
the field wiring
1, 2 and 4-channel slice
modules or 16 and 32-channel
block modules available
Provide type-specific colour
coding

BL20
MODULAR
I/O BUS
TERMINAL
SYSTEM

Sensors
inductive sensors
inductive sensors for rotary
actuators
uprox inductive sensors
capacitive sensors
magnetic-field sensors
photoelectric sensors
machine safety equipment
ultrasonic sensors
levelprox level sensors
flow controls
pressure controls
temperature controls
identification systems
linear position sensors
rotary position sensors
connectors
CD-ROM Sensors

Interfacetechnik
Interfacetechnik im Aufbaugehuse
fr Hutschienen- (DIN 50022),
Platten- oder Bodenmontage
Interfacetechnik auf 19"-Karte
fr Baugruppentrger (DIN 41494)
Miniaturrelais, Industrierelais,
Zeitwrfel, Sockel
Zeit- und berwachungsrelais
Ex-Schutz Grundlagen fr
die Praxis (bersichtsposter)
CD-ROM Interfacetechnik

Interface technology
devices in modular housings
for top-hat rail (DIN 50022) or
panel mounting
devices on 19" card
for DIN-rail mounting (DIN 41494)
miniature relays, industrial
relays, time cubes, sockets
programmable relays and timers
explosion protection basics for
practical application (overview poster)
CD-ROM Interface technology

Feldbustechnik
busstop-Feldbuskomponenten
Bussystem sensoplex2
Bussystem sensoplex2Ex
Bussystem sensoplexMC
Bussystem AS-Interface
Bussystem DeviceNet
Ethernet Netzwerkkomponenten
BL20 modulares FeldbusI/O-System in IP20
BL67 modulares FeldbusI/O-System in IP67
Bussystem FOUNDATION
fieldbus
Bussystem PROFIBUS-DP
Bussystem PROFIBUS-PA
Bussystem piconet
Remote I/O excom

Fieldbus technology
busstop fieldbus components
bus system sensoplex2
bus system sensoplex2Ex
bus system sensoplexMC
bus system AS-Interface
bus system DeviceNet
Ethernet network components
BL20 modular fieldbus
I/O-system in IP20
BL67 modular fieldbus
I/O-system in IP67
bus system FOUNDATION
fieldbus
bus system PROFIBUS-DP
bus system PROFIBUS-PA
bus system piconet
Remote I/O excom

FAX-ANTWORT/FAX REPLY
Absender/Sender:

Hans Turck GmbH & Co. KG


D-45466 Mlheim an der Ruhr
Phone
(+49) (2 08) 49 52-0
Fax
(+49) (2 08) 49 52-264
E-Mail
turckmh@mail.turck-globe.de
Internet www.turck.com

Name:
Firma/Company:
Abt./Position:
Adresse/Address:

Are suited to permanent wiring


Require no tools for mounting

*D3004341103*

All stations consist of a bus


coupler and the required electronic and base modules

Please send me more information:

Sensortechnik
Induktive Sensoren
Induktive Sensoren fr
Schwenkantriebe
uprox induktive Sensoren
Kapazitive Sensoren
Magnetfeldsensoren
Opto-Sensoren
Gerte fr den Personenschutz
Ultraschall-Sensoren
levelprox-Fllstandssensoren
Strmungswchter
Druckwchter
Temperaturwchter
Identifikations-Systeme
Linearweg-Sensoren
Drehweg-Sensoren
Steckverbinder
CD-ROM Sensortechnik

Tel./Phone:
E-Mail:

Fax:

D300434 1103

Compact and safe system construction

Bitte senden Sie mir Unterlagen:

THE BL20 I/O SYSTEM: OPEN, MODULAR,


FLEXIBLE
Open, modular and extremely
flexible:
Our universal bus terminal system
BL20 is designed to plan and
implement tailor-made IP20 I/O
solutions.
All types of signals are freely
combinable
Independently of the type of fieldbus, the user is able to combine
all types of I/O modules and to configure the required I/0 channels bitby-bit: whether analogue or digital
signals, 1, 2, 4, 16 or 32 channels
or block and slice versions. The
customer only has to buy the exact
number of channels needed a
really cost-effective solution right
from the start!

Slice-type
electronic module

INDIVIDUAL CONFIGURATION
FUTURE-PROOF INVESTMENT
The mechanical coding
system
For grouping of electronic
and base modules

Prevents interchange errors


when exchanging electronic
modules

Fieldbus independence through


gateways
The BL20 I/O system is designed
for integration into all major fieldbuses. Gateways are the link
between the fieldbus system and
the I/O modules. They control the
entire data communication. Based
on this concept, the system is open
to new bus technologies and is
thus a safe investment. All you need
to do is to exchange the gateway
you can continue to use the I/O
modules.

Freely combinable components at the I/O level

The gateway concept is open


to new bus technologies
Gateways for all frequently used
fieldbus systems, e.g.
PROFIBUS-DP, CANopen,
DeviceNet, INTERBUS
I/O modules independent of the
fieldbus system

Pluggable electronic modules in


versatile designs as block or slice
models
Freely combinable signal mix,
i.e. bit-by-bit configuration of
channels
Economical: no additional costs
through unused channels

Block-type
electronic module

The relay module


Simple planning and
fast diagnosis with
the I/Oassistant

For direct supply in combination


with certain base modules
(e.g BL20-S4T-SBCS)
Bridging of the relays
common potential
and reduction of
wiring through
cross connection
links

Power supply modules may also be


freely combined. Moreover, it is
possible to configure applicationspecific potential groups anywhere
within the BL20 system.
Modular terminal blocks
The base modules offer an additional advantage: all common sensors
and actuators in 2, 3 or 4-wire
technology may be directly connected using tension springs or
screw connections. Additional connections are not needed.

Open to future bus technologies

Slice-type base
module

The bus
refreshing
module

The gateway
Power-feeding
module

For connection of
BL20 field devices
to the fieldbus
Supports PROFIBUS-DP,
DeviceNet, CANopen or
INTERBUS fieldbus protocols
Coordinates the complete
process data communication
Fieldbus connection via direct
wiring or via fieldbus-specific
connectors, e.g. SUB-D

Gateway

Block-type base
module

For system supply of


the BL20 modules and the
gateway via the internal
module bus
For field supply of the modules
with 24 VDC
For assembly of potential groups

Transfers
diagnosis data to
the higher level control-system
For setting of fieldbus addresses

With integrated interface


for I/Oassistant software

Provides diagnostic functions:


monitoring of the field voltage,
the module bus supply and
module overload

The power feeding module


For field supply of the
BL20 modules with 24 VDC or
120/230 VAC
For assembly of potential groups
Provides diagnostic functions:
fieldbus voltage monitoring

www.turck.com

BL20

Selection of the required


modules
Configuration, parameterisation and set-up of each
station
Reading and adjustment of
process data
Diagnosis and error handling
Based on Windows