Turn-On & Commissioning Handbook

Alcatel 1642 Edge


Multiplexer
STM 1 Multi-Service Edge Multiplexer for Customer Premises

1642 Edge Multiplexer Rel.2.1

3AL 97156 ACAA Ed.01 TQCVA

RELATED TECHNICAL HANDBOOK:

HANDBOOK
1642 Edge Multiplexer Rel. 2.1 Technical Handbook

ANV Part No.


3AL 97156 AAAA ED01 TQCVA

SAFETY RULES
Before carrying out any installation, turn-on, tests & operation and maintenance operations, read
carefully the Safety Rules described in Technical Handbook
s section HANDBOOK GUIDE.

HANDBOOK COMPOSITION (present edition)


part

1
2

No pages

Numbered
From
1/50
1/2

HANDBOOK
TEST REPORT

3AL 97156 ACAA Ed.01 TQCVA

to
50/50
2/2

ASB 1642 Edge Multiplexer


TURN-UP & COMMISSIONING

01

04/07/02

ED

DATE

CHANGE NOTE

Chang Haiyan
Lennart Priester

Xu Jun

APPRAISAL AUTHORITY

ORIGINATOR

1642EM Rel 2.1 TURN-UP & COMMISSIONING

ED

01
3AL 97156 ACAA TQCVA

1/50

ED

01
3AL 97156 ACAA TQCVA

2/50

TABLE OF CONTENTS
1

CHANGES........................................................................................................... 5

GENERAL............................................................................................................ 5
2.1 Safety Rules................................................................................................................................. 5
2.2 Symbols glossary......................................................................................................................... 5

INITIAL TURN-ON, TESTS AND OPERATION.................................................................... 6


3.1 Initial turn-on sequence instruction................................................................................................ 6
3.2 Visual inspection for subrack installation and cabling ..................................................................... 6
3.3 HW setup.................................................................................................................................... 6
3.4 Start up procedure....................................................................................................................... 7
3.4.1 Equipment Switch-on ........................................................................................................... 7
3.4.2 PC and 1320CT Start-up ..................................................................................................... 7
3.4.3 Software Download Procedure.............................................................................................. 7
3.5 NE Software Settings...................................................................................................................17
3.5.1 Preset the Equipment Configuration with 1320CT .................................................................17
3.5.2 Cross Connection Settings for Local Measures with 1320CT ..................................................17
3.5.3 Standard connections .........................................................................................................17
3.5.4 The maintenance of the DB .................................................................................................17
3.6 Measurements............................................................................................................................20
3.6.1 Instruments Accessories and related documents ....................................................................20
3.7 Connection points position..........................................................................................................22
3.7.1 MB main board..................................................................................................................22
3.8 Local Measures list and operating sequence .................................................................................24
3.8.1 Free running frequency check..............................................................................................25
3.8.2 Electrical ports check ..........................................................................................................28
3.8.3 Optical ports test................................................................................................................34
3.8.4 SNCP check (line ports) .......................................................................................................37
3.8.5 Auxiliary channel check.......................................................................................................40
3.8.6 Housekeeping alarm check (if connected) .............................................................................43
3.8.7 Final checks .......................................................................................................................46

ANNEXES...........................................................................................................47
4.1 Annex - Bi-directional protected cross-connection between a 2 Mbit/s port and STM-n port ..............47
4.2 Annex - Bi-directional protected cross-connection between a 34 Mbit/s port and STM-n port ...........48
4.3 Annex - Optical Parameter values................................................................................................49
4.4 Annex - LAPD configuration.........................................................................................................50

ED

01
3AL 97156 ACAA TQCVA

3/50

TABLE OF LABLES AND FIGURES


Tables

Table 1
Table 2
Table 3
Table 4
Table 5
Table 6
Table 7

Terminal Cable Signals Table ..................................................................................................... 9


Instruments ............................................................................................................................. 20
Accessories ............................................................................................................................. 20
Documents reference list .......................................................................................................... 21
V.24 ....................................................................................................................................... 42
Definition of E2, F1 user path cables......................................................................................... 42
Parameters specified for STM-1 Optical Interface ....................................................................... 49

Figures
Figure 1 - Hyper terminal, configure the serial port .................................................................................... 8
Figure 2 - Install the Alcatel Serial Cable modem step 1 ........................................................................... 10
Figure 3 - Install the Alcatel Serial Cable modem step 2 ........................................................................... 10
Figure 4 - Install the Alcatel Serial Cable modem step 3 ........................................................................... 11
Figure 5 - Install the Alcatel Serial Cable modem step 4 ........................................................................... 11
Figure 6 - Install the Alcatel Serial Cable modem step 5 ........................................................................... 12
Figure 7 - Running update_rawloader.exe ............................................................................................... 12
Figure 8 - Downloading procedure ......................................................................................................... 13
Figure 9 - Backup of MIB........................................................................................................................ 17
Figure 10 - Downloading procedure ....................................................................................................... 18
Figure 11 - Downloading procedure ....................................................................................................... 18
Figure 12 - MB board, panel view ........................................................................................................... 22
Figure 13 - Connection Points on the rear of 1642 Edge Multiplexer.......................................................... 23
Figure 14 - Free-running frequency check................................................................................................ 26
Figure 15 - Test on multi-demultiplexing and AIS for electrical ports........................................................... 29
Figure 16 - Test Ethernet switch on local ports .......................................................................................... 32
Figure 17 - Test on multi-demultiplexing and AIS for optical tributaries ...................................................... 35
Figure 18 - Test on multi-demultiplexing and AIS for electrical ports........................................................... 38
Figure 19 - V24 auxiliary channel check .................................................................................................. 41
Figure 20 - House keeping alarm check.................................................................................................. 44
Figure 21 - E1 cross connect configuration .............................................................................................. 47
Figure 22 - DS3 cross connect configuration............................................................................................ 48

ED

01
3AL 97156 ACAA TQCVA

4/50

1 CHANGES

ISSUE

DATE

01

2004-07-02

CHANGE NOTE

First edition

2 GENERAL
2.1 Safety Rules
The Safety Rules describe the operations and/or precautions to observe to safeguard operating personnel
during the working phases and to guarantee equipment safety.
Please read all the instructions given in the Technical Handbook and Operators Handbook properly before
starting each action on the equipment.

2.2 Symbols glossary


To simplify the description, some symbols have been used to describe actions.
The table below shows the symbols and their relevant meaning.
Symbols used

CT
NES
EML-USM

ED

Meaning
Action
Check/Verify
On Craft Terminal Select
On Network Element Synthesis
On Element Management Level-User Service Manager
Select
On Pattern Generator/Error Detector (Instrument) Operation

01
3AL 97156 ACAA TQCVA

5/50

3 INITIAL TURN- ON, TESTS AND OPERATION


3.1 Initial turn-on sequence instruction
The paragraphs that follow list the instructions that must be sequentially executed as well as additional
information.

3.2 Visual inspection for subrack installation and cabling


Rack allocation: according to station layout.
Rack configuration (units installed): according to plant documentation.
Connections between equipment and DDF/ODF: according to plant documentation.
Rack ground connections (cable section).
Power Supply connections (polarity and cable section) if direct connections to exchange battery exist.

3.3 HW setup

Unit setting options are factory pre-set. To check hardware set-up, following malfunction, proceed as
instructed in the specific chapter of the Technical Handbook.

ED

01
3AL 97156 ACAA TQCVA

6/50

3.4 Start up procedure


The scope of this procedure is to illustrate the start-up phases of the Equipment and 1320CT.
3.4.1 Equipment Switch-on
The Equipment is started up through the ON switch of power supply interface board in Slot 6.
3.4.2 PC and 1320CT Start-up
3.4.2.1

PC Start-up

Computer hardware configuration


The computer configuration to be used as a 1320CT support consists of:
-

Basic requirement:
CPU Pentium 800 MHz
RAM
128 Mbit/s (256 Mbit/s suggested)
HARD DISK
2Gb (4Gb suggested)
MONITOR
15 (17 suggested)
RESOLUTION
1024 x 768 pixel
CD-ROM drive
Ethernet port
One 3 floppy disk drive (1.44 MB)

Computer software configuration


The following software items are required:
l

WINDOWS 2000 + Service Pack 3 (Copyright Microsoft Corporation)

Software product (CD-ROM) contains NE software package and 1320CT setup package

3.4.2.2

1320CT Start-up

The procedure below is utilized to start the 1320CT.


Procedure
->Connect the serial port of PC to the F interface connector located on the 1642EM MB in slot 1.
->Select the 1320CT to start the application.
->Select the Supervision\Startmenu to supervise NE.
->Select the Supervision\NE Login menu to log in NE. (Login User/Password: ADMIN/ ADMIN)

Menu and the wizard window will guide step by step.


N.B.

For a detailed description of the software menu refer to the Operators Handbook.

3.4.3 Software Download Procedure

ED

01
3AL 97156 ACAA TQCVA

7/50

3.4.3.1

Query the Boot Flash Version

Step 1: Connect DBG_L port located on the MB and PC with Terminal cable. Then open Start ->
Programs -> Accessories -> Communications -> Hyper terminal, and configure the serial port as Figure 1:

Figure 1 - Hyper terminal, configure the serial port


Step 2: When hyper terminal appears pSH+>, type reset r, then the system goes into rawloader
environment. And type plat to check the version of boot flash.
>plat
EQ Raw Loader Platform Version: 'V8.1.0'
Date: May 22 2003
Board Configuration
---------------Micro Revision Number
: 502
Instruction Cache
: enabled
MMU
: disabled
Phisical Ram Size Equipped: 64Mbytes
Ram Size Configured
: 8Mbytes

ED

01
3AL 97156 ACAA TQCVA

8/50

EQ Raw Loader Platform Libraries Version:


---------------LIB:
LIB:
LIB:
LIB:
LIB:
LIB:

ldr_lib_rwl - REL: 'RWL-PQ1-EECRC''V8.1.0'P43 (May 22 2003)


vfs_lib - REL: 'VFS-PQ1-GEN''V7.4.2'(Nov 26 2001)
llc2_lib - REL: 'CS-PQ1-GEN-LLC2''V7.4.2'(Jan 14 2002)
ec_lib_NP - REL: 'KS-PQ1-EECRC''V8.1.0'P43 (May 22 2003)
ks_libRW - REL: 'KS-PQ1-GECRC''V8.1.0'P43 (May 22 2003)
libbsp - REL: 'KS-PQ1-GECRC''V8.1.0'P43 (May 22 2003)

The version of rawloader now is V8.1.0 P43, created on May 22 2003, which is the latest one. If the version is
older than V8.1.0 P43, the boot flash must be updated.
Close hyper terminal.
N.B. Terminal cable is not provided for the customer unless it has been bought. But it can be made as
following:
One end of Terminal cable is RJ11 for the DBG_L port (shown in the following figure), and the other end is DB9 (female)
for the PC. The signals related to pins are shown at the following table.

Table 1 - Terminal Cable Signals Table


DBG_L
Signals name
DBG_TXD
DBG_RXD
DBG_DTR
GND

3.4.3.2

RJ11
Connector pin (Pins are at the top)
2
3
4
5

DB9
Pin (female)
3
2
4
5

Boot flash update procedure with SIBDL2.1.3 in Windows2000

1. Install the SIBDL tool in the PC, the setup file is in the folder \BOOTROM of CD-ROM. Change the
installation folder name from SIBDL 2.1.3 to SIBDL213.
2. Install the Alcatel Serial Cable modem. In Control Panel/Phone and Modem Options/Modems, you can
add modem to the system. As Fogure 2 shows.

ED

01
3AL 97156 ACAA TQCVA

9/50

Figure 2 - Install the Alcatel Serial Cable modem step 1


when the window is displayed, select [Don't detect my modem; I will select it from a list] as Figure 3 shows.

Figure 3 - Install the Alcatel Serial Cable modem step 2


In the next dialog, press [Have Disk] and choose the installation path, where mdmalca.inf is
stored. then press [Ok] as Figure 4.

ED

01
3AL 97156 ACAA TQCVA

10/50

Figure 4 - Install the Alcatel Serial Cable modem step 3


Select "Serial Cable" modem and press [Next] as Figure 5 shows.

Figure 5 - Install the Alcatel Serial Cable modem step 4


Select only one serial port (COM1 is recommended but not mandatory) as Figure 6 shows.

ED

01
3AL 97156 ACAA TQCVA

11/50

Figure 6 - Install the Alcatel Serial Cable modem step 5


press [Next], [Finish] and [Close]
Now, Alcatel Serial Cable Modem is installed successfully.
3. Download
Step 1: Remove the flash card from PQ/ECSC module mounted in MB.
Step 2: Connect DBG_L port located on the MB and PC with Terminal cable. Then open hyper terminal.
Step 3: Power on the 1642EM. When HyperTerminal appears pSH+>, type reset g, the system will go
into genesis, and the prompt is GEN>
Step 4: Close Hyperterminal window.(Because the Hyperterminal and SIBDL use the same serial port i.e.
COM1)
Step 5: Go into the installation folder of SIBDL2.1.3, double click update_rawloader.exe, and a command
window will appear as Figure 7.

Figure 7 - Running update_rawloader.exe


Press d key for next step.
Step 6: Type the directory where there is the rawloader version that you want download, for example
H:\BOOTROM. Press enter for next step.
ED

01
3AL 97156 ACAA TQCVA

12/50

Step 7: Type the serial_port_name connected to the PC, for example COM1, press enter for next step.
Step 8: Type the rawloader_name that you need to download, for example bootrom_V1.1.x. Press enter
for next step.
Then, the following window will appear in figure 8 and the SIBDL will do the reset working until finish
downloading.

Figure 8 - Downloading procedure


After all is finished, type return and the window will close.
Step 9: Open Hyperterminal and type reset p, then the system goes into Rawloader enviroment. And type
plat to check the version of boot flash.
>plat
EQ Raw Loader Platform Version: 'V8.1.0'
Date: May 22 2003
Board Configuration
---------------Micro Revision Number
: 502
Instruction Cache
: enabled
MMU
: disabled
Phisical Ram Size Equipped: 64Mbytes
Ram Size Configured
: 8Mbytes
EQ Raw Loader Platform Libraries Version:
---------------LIB:
LIB:
LIB:
LIB:
LIB:
LIB:

ldr_lib_rwl - REL: 'RWL-PQ1-EECRC''V8.1.0'P43 (May 22 2003)


vfs_lib - REL: 'VFS-PQ1-GEN''V7.4.2'(Nov 26 2001)
llc2_lib - REL: 'CS-PQ1-GEN-LLC2''V7.4.2'(Jan 14 2002)
ec_lib_NP - REL: 'KS-PQ1-EECRC''V8.1.0'P43 (May 22 2003)
ks_libRW - REL: 'KS-PQ1-GECRC''V8.1.0'P43 (May 22 2003)
libbsp - REL: 'KS-PQ1-GECRC''V8.1.0'P43 (May 22 2003)

The version of rawloader now is V8.1.0 P43, created on May 22 2003, which is the latest one.
Till now, the rawloader is update d successfully.
Step 10: Plug the flash card into PQ/ECSC module.

ED

01
3AL 97156 ACAA TQCVA

13/50

3.4.3.3
Software download with FTP procedure (when flash card is blank, usually in the process of
installation)
1. Connect DBG_L port located on the MB to the PC serial port using Terminal cable, Q interface located on
MB to the PC Ethernet port (or hub). Then open Start -> Programs -> Accessories -> Communications ->
Hyper terminal.
2. Watch the prompt as pSH+> display ing on hyper terminal.
3. To format a flash card is to act as follow (The bold characters need to be type d. Please note that the
command is case sensitive):
pSH+> reset r
pSH+> format
WARNING: Scratch FC. You loose all the data saved on it.
Are you sure? Enter y to confirm:_y
Volume 3.0.0 successfully unmounted
VFS: Driver diagnostic successful
Initialize the disk volume using pHILE+ File System Format
Volume statistcs:
preferred file system block size : 0x200
fundamental fs block size
: 0x200
total blocks in the volume
: 62336
free blocks
: 59563
free blocks available to non-super-user : 59563
total file nodes in file system : 11004
free file nodes in volume
:0
free file nodes to non-super-user: 0
target fs type name
: pHILE+
maximum specific string
: 255
VFS successfully formatted
Then CF is formatted successfully.
After that the directory structure is shown as follow:
pSH+> du
0
0
0
0
0
0
1
2
2770

./home/adm-lc-ng/debug
./home/adm-lc-ng/boardSwVs
./home/adm-lc-ng/config
./home/adm-lc-ng/Database
./home/adm-lc-ng/logs
./home/adm-lc-ng/perfmon
./home/adm-lc-ng
./home
.

4. Make a specific directories structure


Use mkdir command to make the directories as the following structure. The bold and italic is the directory
necessary to make, and the name cant be changed to others.
pSH+> du
0
./home/adm-lc-ng/debug
16385 ./home/adm-lc-ng/boardSwVs/NE_1642 /ES1
16386 ./home/adm-lc-ng/boardSwVs/NE_1642
16385 ./home/adm-lc-ng/boardSwVs/NE_1642 /EC
16386 ./home/adm-lc-ng/boardSwVs/NE_1642
16409 ./home/adm-lc-ng/boardSwVs

ED

01
3AL 97156 ACAA TQCVA

14/50

3
./home/adm-lc-ng/config
0
./home/adm-lc-ng/Database
0
./home/adm-lc-ng/logs
0
./home/adm-lc-ng/perfmon
16413 ./home/adm-lc-ng
232
./home/fpga
58
./home/mcode
23406 .
5. Initialize the Q interface for FTP
Initialize Q interface for 1642EM as follow:
pSH+> ins_ qlan (You can type help to view the command.)
lan_IP_add (0x00000000): 0xac18d7e0(can set any value that would not collide.)
lan_mac_add (0x000000000000): 0xac18d7e01234
lan_ntwk_mask (0x00000000): 0xfffffe00
Lan Network Interface initialized
6.
FTP files to Flash card,
(etc.ac18d7e0172.24.215.224).

Ftp

to

1642EM

using

the

IP

address

just

configured

N.B. Ftp method: DOS command, or FlashFXP, or CuteFTP, or AbsoluteFTP tools etc.
FOR Q3:
FTP CD-ROM\ECSC\ \V010000_0 to the directory /home/adm-lc-ng/boardSwVs/NE_1642/EC using
binary mode.
FOR SNMP(for board ISA-ES1 8FE):
FTP CD-ROM\ISA_ES1_8FE\V010000_0 to the directory /home/adm-lc-ng/boardSwVs/NE_1642/ES1 using
binary mode.
FOR SNMP(for board ISA-ES1 3FE):
FTP CD-ROM\ISA_ES1_3FE\V010000_0 to the directory /home/adm-lc-ng/boardSwVs/NE_1642/ES1 using
binary mode.

NOTE:
In this release, the board ISA-ES1 8FE and board ISA-ES1 3FE cant be used at the
same time in one NE. It is necessary to download different software to support the two types
of boards.
Ftp all the .mky files as following to the directory home/fpga using binary mode.
CD-ROM\ministry\V2.7\ministry.mky (for MB)
CD-ROM\multiio\V1.4\multiio.mky (for MB)
CD-ROM\repass\V2.0\repass.mky (for E1RCB8)
CD-ROM\secer\V1.3\secer.mky (for OT1B1)
CD-ROM\smack\V1.1\smack.mky (for SCM)
CD-ROM\marbiter\V1.2\marbiter.mky (for ISA-ES1 8FE and ISA-ES1 3FE)
CD-ROM\mower\V1.2\mower.mky (for OWM)
Ftp CD-ROM\OT1M1-MCODE\V1.0\ot1m1.bin file to the directory home/mcode
7. Initialize the boot table in Hyper terminal platform
Initialize the boot table according to the following steps:

ED

01
3AL 97156 ACAA TQCVA

15/50

FOR Q3:
pSH+> ins_boot EC
Insert the equipment type: NE_1642 (defined before when make this directory)
FOR SNMP:
pSH+> ins_boot ES1
Insert the equipment type: NE_1642 (defined before when make this directory)

Insert the application version (V000000): V010000(defined before when ftp this file)
V010000_0
Version Status:
1 - Active
2 - Standby
Insert your choice: 1
Software Format:
1 - BINARY
2 - IEEE695
3 - ELF
Insert your choice: 1

Insert the application starting address (0x000000): 0x100000


pSH+>reset p
pROBE+>gs (when the Terminal cable is still plugged in the DBG_L port of MB board)
pROBE+>go (when the Terminal cable is still plugged in the DBG_L port)

NOTE:
If the flash card is empty, the operation reset p must be implemented twice.
3.4.3.4

Software download with 1320CT procedure (when flash card is already written)

Start 1320CT:
In the Network Element Synthesis window,
-> Select Supervision/File Administration/Software Package Administration
-> Click Install button, choose the dsc file to download, then click Closebutton.
Log in the NE,
-> Select Download/Init download
-> Select the package to download, click OK
-> Waiting till the end of the download then click Closebutton
After finish the download,
-> Select Download/Units info
-> Select the downloaded package, Select Current state\Action Activate, click OK

NOTE: If upgrade ECSC software from previous version to R2.1 by CT, it is necessary to
download package 1642EMfirstly, after it runs OK, then download package 1642EME.

ED

01
3AL 97156 ACAA TQCVA

16/50

3.5 NE Software Settings


3.5.1 Preset the Equipment Configuration with 1320CT
The equipment configuration in 1320CT complies with the units really inserted into the equipment being tested.
N.B.

For a detailed description of the software menu refer to the Operators Handbook.
3.5.2 Cross Connection Settings for Local Measures with 1320CT

The following are the characteristics of the initial Cross Connection:


All possible protections (electrical and optical) must be included.
The equipment works in the Free-running mode.
N.B.

For a detailed description of the software menu refer to the Operators Handbook.
3.5.3 Standard connections

Use the procedures reported in the ANNEXES for the unidirectional matrix loopback connections of all ports
present (of any type of bit rate):
-

Annex - Bi-directional protected cross-connection between a 2 Mbit/s port and STM-n port

Annex - Bi-directional protected cross-connection between a 34 Mbit/s port and STM -n port
3.5.4 The maintenance of the DB
3.5.4.1

Backup of MIB

In any cases, the backup of DB is very important. To backup up the DB, user can use the command
download/mib management on the main menu. The window likes following in Figure 9 will appear:

Figure 9 - Backup of MIB


ED

01
3AL 97156 ACAA TQCVA

17/50

In the BACKUP name, user should type in the name of the mib_backup, then click Backup button. The system
will ask for the confirmation of backup, just click OK.
Then the following window in Figure 10 will appear, showing the backup is in process.
N.B. Do not click OK, otherwise backup will be cancelled.

Figure 10 - Downloading procedure

After 3-4 minutes, success will be shown as Figure 11:

Figure 11 - Downloading procedure

ED

01
3AL 97156 ACAA TQCVA

18/50

At present, the mib backup has been OK.

3.5.4.2

Delete of MIB

To delete the MIB with hardware, user can modify the state of the switch (U30) on the main board.
To delete the MIB, the switches should be in the following state:
1: OFF
2: ON
After setting the switch in this state and plug in the main board, the system will delete the MIB and create a
new MIB with default value, then displays Please wait some minutes and restart me.
Then the user should pull out the main board and set the swithc in the following state:
1: OFF
2: OFF
then reset the system again to make the new MIB work.
If the system is set up for the first time. After formatting the flash, downloading the application, one reset is
necessary(reset p). After reset, the system will also create the new MIB with default value and display Please
wait some minutes and restart me when no MIB is found. User should reset the system to make the new MIB
work. SO totaly the system should be reset twice for the first set up.

ED

01
3AL 97156 ACAA TQCVA

19/50

3.6 Measurements
3.6.1 Instruments Accessories and related documents
Table 2 - Instruments
REF.

Q.TY

CHARACTERISTICS

(A)

Pattern Generator/Error Detector

INSTRUMENTS

(B)

Optical power tester (radiometer)

(C)

(D)
(E)

Single-mode
variable
optical
attenuator
Digital multimeter
Craft terminal (Personal Computer)

(F)

Data Tester

(G)

Frequency counter

Signals available:
- 2048 Kbit/s code HDB3 (120/75 ohms)
- 34 Mbit/s code HDB3
- ATM module
- Ethernet 10/100 Mbit/s
- GFP over SDH module
2nd window
3rd window
Variable attenuator within the 0-50dB, 2nd
and 3rd window
See the operators handbook.
It can be supplied by ALCATEL.
Tx rate up to 64 Kbit/s contra-directional ITU-T
interface V.24
10 MHz 1 Hz

Q.TY

CHARACTERISTICS

Table 3 - Accessories
REF.

ACCESSORIES

(H)

Coaxial Cables

(I)

Single-mode single-fiber splices

(L)

Shielded pair

(M)

Optical loop

(N)

Craft Terminal cable

(O)

Cable for synchronism

(P)

Cable for F1, E2 ports

(Q)

CA House Keeping Cable

ED

Terminations:
instrument side depending on (A)
equipment side depending on type of DDF
Terminations
dependent
on
unit/ODF
connectors, radiometer and attenuator
Termination:
instrument (F)/(A)
channels RJ45 for Ethernet ports
Terminations
dependent
on
unit/ODF
connectors
loss=12 dB
Termination:
PC connector (F interface)
F interface on main board
Terminations:
instrument side depending on (G)
equipment side is 75ohm coax connector
(1AB 06122 0003)
Terminations:
instrument side depending on (F)
equipment side depending on type of
connector (3AL 97091 AAAA)
Terminations:
instrument side depending on house
keeping equipment (3AL 97088 AAAA)
equipment side depending on type of
connector

01
3AL 97156 ACAA TQCVA

20/50

Table 4 - Documents reference list


DOCUMENT TYPE
1642EM 2.1 Installation Handbook
1642EM 2.1 Operators Handbook
1642EM 2.1 Technical Handbook

ED

PART No.
3AL 97156 ABAA TQCVA
3AL 97156 ADAA TQCVA
3AL 97156 AAAA TQCVA

01
3AL 97156 ACAA TQCVA

21/50

3.7 Connection points position


3.7.1 MB main board
Acronym
MB

Slot
1
(1)
(2)
(3)

(4)

(5)

(6)
(10)
(11)
(12)
(13)
(14)
(15)

(7)

(1) RUN LED


(2) COMMON ALARM
(3) SERIOUS ALARM
(4) Q PORT
(5) F PORT
(6) Channel A E2 PORT
(7) Channel A F1 PORT
(8) Channel B E2 PORT
(9) Channel B F1 PORT
(10) Housekeeping input0
(11) Housekeeping input1
(12) Housekeeping input2
(13) Housekeeping output0
(14) Housekeeping output1
(15) Housekeeping output2
(16) Debug port
(17) 2M external clock output
(18) 2M external clock input
(19) OWM connector
(20) OWM LED
(21) OTA alarm LED
(22) OTB alarm LED
(23) OTA input
(24) OTA output
(25) Reset button
(26) OTB input
(27) OTB output

(8)
(9)

(16)
(17)

(20)
(21)
(22)

(18)
(19)

(23)
(24)

(25)

(26)
(27)

Figure 12 - MB board, panel view

ED

01
3AL 97156 ACAA TQCVA

22/50

FEB6
Slots 2,3,4,5

E3B1 or DS3B1
Slots 2,3,4,5

E1B28 or DE1B28
Slots 2,3,4,5

E1B8 or DE1B8
Slots 2,3,4,5

E1RCB8
Slots 2,3,4,5

OT1B1
Slots 2,3,4,5

ISA-ES1 8FE
Slots 2,3

ISA-ES1 3FE
Slots 2,3

DE1B32
Slots 2,3,4,5

ET1B1
Slots 2,3,4,5

Figure 13 - Connection Points on the rear of 1642 Edge Multiplexer

ED

01
3AL 97156 ACAA TQCVA

23/50

3.8 Local Measures list and operating sequence

The purpose of local measures is to check the correct operating mode of the equipment units.
Free running frequency check (para 3.8.1 on page 25)
Electrical ports check (para 3.8.2 on page 28)
Multi-demultiplexing check and AIS forwarding to E1/E3 port (one by one port with software loop at
matrix level) (para 3.8.2.1 on page 28)
Local switch function test (para 3.8.2.2 on page 31)
Optical ports test (para 3.8.3 on page 34)
SNCP protection check (line ports) (para 3.8.4 on page 37)
Auxiliary channel check (para 3.8.5 on page 40)
Housekeeping alarm check (if connected) (para 3.8.6 on page 43)
Final checks (para 3.8.7 on page 46)

ED

01
3AL 97156 ACAA TQCVA

24/50

3.8.1 Free running frequency check


-

Purpose
Verify the correct frequency value of the oscillator on the 1642EM CM.

Test instruments (see Table 2).


Craft Terminal (E)
Frequency Counter (G)

Accessories (see Table 3)


Cable for synchronism (O)
Craft Terminal cable (N)

ED

01
3AL 97156 ACAA TQCVA

25/50

Test Bench

Slot 4

Slot 5

Slot 2

Slot 3

Frequency
counter

Figure 14 - Free-running frequency check

ED

01
3AL 97156 ACAA TQCVA

26/50

Procedure

1320CT

ED

Select Views Synchronization menu

Check in the Synchronization View, the object Timing Generator is freerunning

Connect the frequency counter to 2Mbps clock signal output port of MB


Check that the clock free-running frequency is 2048Kbit/s 4.6 ppm.

01
3AL 97156 ACAA TQCVA

27/50

3.8.2 Electrical ports check


3.8.2.1
Multi-demultiplexing check and AIS forwarding to E1/E3 port (one by one port with software loop
at matrix level)
-

Purpose
The test verifies the Bit Error Rate at the electrical port of DDF as specified for the connections reported in
the Plant Documentation.

Test instruments (see Table 2)


Craft Terminal (E)
Pattern Generator/Error Detector (A)

Accessories (see Table 3)


Coaxial cable (H) or Shielded pair (L)
Craft Terminal cable (N)

Test Bench
Set up the loop via software.

ED

01
3AL 97156 ACAA TQCVA

28/50

DDF
(if present)

Pattern Generator/
Error detector

E1RCB8
Slots 2,3,4,5

E1B28 or DE1B28
Slots 2,3,4,5

E1B8 or DE1B8
Slots 2,3,4,5

DS3B1 or E3B1
Slots 2,3,4,5

As altinative
Slot 4

Slot 5

Slot 2

Slot 3

ODF

Figure 15 - Test on multi-demultiplexing and AIS for electrical ports


ED

01
3AL 97156 ACAA TQCVA

29/50

Procedure

F Preset the instrument to transmit a signal (based on the type of port used) with the following requirements:
Bit rate
Code
Sequence
Level

2048 Kbit/s 50 ppm


HDB3
215 -1 pseudorandom
2.3Vp (75 ohm) or
3Vp (120 ohm)

34368 Kbit/s 20 ppm


HDB3
223 -1 pseudorandom
1 Vp (75 ohm)

F Connect the Pattern Generator to the input and output of a port to be tested.

Check that the Error Detector has read no errors and that there are no alarm indications on the units
involved.

F Disconnect the Pattern Generator output from the port.

Check if AIS signal (all ONES) is present (sent from the output side of the port involved to the Error
Detector).

LOS is present on the C.T.

F Repeat the checks on all the other ports of the Bit rate.

ED

01
3AL 97156 ACAA TQCVA

30/50

3.8.2.2
-

Local switch function test

Purpose
The test verifies the Bit Error Rate at the electrical port of DDF as specified for the connections reported in
the Plant Documentation.

Test instruments (see Table 2)


Craft Terminal (E)
Pattern Generator/Error Detector (A)

Accessories (see Table 3)


Shielded pair (L)
Craft Terminal cable (N)

ED

01
3AL 97156 ACAA TQCVA

31/50

Test Bench
Local switch function test of the 10/100 Mbit/s Ethernet port, dont need to set up the matrix loop via
software.

Ethernet
Switch

Pattern Generator/
Error detector
FEB6

Slots 2,3,4,5

Slot 4

Slot 5

Slot 2

Slot 3

Figure 16 - Test Ethernet switch on local ports

ED

01
3AL 97156 ACAA TQCVA

32/50

Procedure

F Preset the instrument to transmit a signal (based on the type of port used) with the following requirements:
Length
Interpacket gap
Type

64byte
9.6ns.
10/100 Mbit/s Ethernet allow Auto Negotiate

F Connect the Pattern Generator to the input and output of a port to be tested.

ED

Check that the Error Detector has read no errors

01
3AL 97156 ACAA TQCVA

33/50

3.8.3 Optical ports test


-

Purpose
1) Let through data to check if the ports are properly connected to the ODF.
2) Check PTx.

Test instruments (see Table 2)


Craft Terminal (E)
Pattern Generator/Error Detector (A)
Power meter
15 dB fixed attenuator

Accessories
Single-mode single-fiber splices (I)
Craft Terminal cable (N)

ED

01
3AL 97156 ACAA TQCVA

34/50

Test Bench
Set up the matrix loop via software.

DDF
(if present)

Pattern Generator/
Error detector

E1RCB8 in any one of Slots

OT1B1 in any one of Slots

Slot 4

Slot 5

Slot 2

Slot 3

ODF

POWER
METER

Figure 17 - Test on multi-demultiplexing and AIS for optical tributaries

ED

01
3AL 97156 ACAA TQCVA

35/50

Procedure

A)

PTx power test

F Connect power meter to the optical port output being tested.

B)

Check that the optical power is within the range stated on the table reported in ANNEX 3.

Insert the signal and test error-free data transit.

Repeat points A), B), and all the optical ports (if OT1B1 is present on slot 2~5).

ED

01
3AL 97156 ACAA TQCVA

36/50

3.8.4 SNCP check (line ports)


-

Purpose
Verify the SNCP efficiency

Test instruments (see Table 2


Craft Terminal (E)
Pattern Generator/Error Detector (A)

Accessories
Optical loop (M)
Coaxial cable (H)
Craft Terminal cable (N)

ED

01
3AL 97156 ACAA TQCVA

37/50

Test Bench

DDF
(if present)

Pattern Generator/
Error detector

E1RCB8
Slots 2,3,4,5

Slot 4

Slot 5

Slot 2

Slot 3

ODF

Figure 18 - Test on multi-demultiplexing and AIS for electrical ports

ED

01
3AL 97156 ACAA TQCVA

38/50

Procedure
Cross-connect trib. port and the line port as reported on the table.
Type of protected cross-connections
2 Mbit/s

STM1

See ANNEX
Annex 1

F Preset the instrument to transmit a signal with the following requirements:


Bit rate
Code
Sequence
Level

2048 Kbit/s 50 ppm


HDB3
215 -1 pseudorandom
2.3Vp (75 ohm) or
3Vp (120 ohm)

Check that no errors are read on the Error Detector.

F Open one of the Optical loop present on the ODF.

ED

Check after a transient condition that the Error Detector reads no errors.

01
3AL 97156 ACAA TQCVA

39/50

3.8.5 Auxiliary channel check

The auxiliary bytes are:


-

F1, E2

The auxiliary channels can be accessed through the corresponding connectors on the rear panel as soon as
the MB is inserted and without any software setting operation.
Purpose
The test verifies the bit error rate on the V24 auxiliary channel
-

Test instruments (see Table 2)


Craft Terminal (E)
Data Tester (F)

Accessories
Optical loop (M)
Shielded pairs (P)
Craft Terminal cable (N)

ED

01
3AL 97156 ACAA TQCVA

40/50

Test Bench
The multiplexing SDH port used like Line port must be looped.

V24
auxiliary
channel

Data
Tester

Slot 4

Slot 5

Slot 2

Slot 3

ODF

Figure 19 - V24 auxiliary channel check

ED

01
3AL 97156 ACAA TQCVA

41/50

Procedure

F Preset the instrument to transmit a contra-directional V24 signal with the following value:
F Connect the instrument to the pins of the ports under test with the following table:
Table 5 - V.24

MENU 1
Interface:
V.24
Frame:
OFF
Emulation:
DTE
Clock:
EXTERNAL

MENU 2
BER sequence:
215-1
Bit/block:
OFF
Rx Logic:
NORM.
Tx Logic:
NORM.

MENU 3
Timer:
OFF
Auto-print:
OFF
G.821:
CCITT
Alarms:
ALL
Resolution:
HOUR/MIN
Buzzer:
ON

Check that no errors are read on the Data Tester. If errors are detected, trouble shoot the electrical
connectors

F Disconnect the pattern generator from the input of the V.24 channel connector and check if the AIS
signal (all ONES) is received at the Data Tester.

Table 6 - Definition of E2, F1 user path cables

E2 F1
Signal
RXD
TXD
GND

RJ11
connector
3
2
5

DB9
connector
2
3
5

RJ11
Connector

Repeat on all the F1, E2 ports

ED

01
3AL 97156 ACAA TQCVA

42/50

3.8.6 Housekeeping alarm check (if connected)


Purpose
Verify the housekeeping alarms.
-

Test instruments (see Table 2).


Craft Terminal (E)

Accessories (see Table 3 on page 20)


Craft Terminal cable (N)

CA House Keeping Cable (Q)

ED

01
3AL 97156 ACAA TQCVA

43/50

Test Bench

Slot 4

Slot 5

Slot 2

Slot 3

HK alarm
Equipment

Figure 20 - House keeping alarm check

ED

01
3AL 97156 ACAA TQCVA

44/50

Procedure

1320CT

Select Views External Points; External Points view will be displayed.

F Label

input configuration,
PointsConfiguration,

select

one

Input

port,

choose

the

menu

External

F Click OK.
F Connect a HK alarm equipment to the HK alarm input port with the valid voltage.

Click the menu DiagnosisAlarmsExternal Points Alarms to check

Check the label colour change on the Input port

F Label

output configuration, select one Output port, choose the menu External
PointsConfiguration, select the External State On and Output Criteria Manual

F Click OK.
F Connect a HK alarm equipment to the HK alarm output port

Check the output port

Repeat on all the HK alarm ports.


N.B. for more detailed info, please refer to Operators Handbook and Installation Handbook

ED

01
3AL 97156 ACAA TQCVA

45/50

3.8.7 Final checks


-

Scope
Check that the equipment has been properly configured.

Test instruments (see Table 2)


Craft Terminal (E)

Accessories (see Table 3)


Cable for Craft Terminal (N)

The following operations must be carried out at the end of the STAND-ALONE tests:

Disconnect all the cross-connections made on the equipment during the test operation phase.

If set down in the executive Design configure the following:


-

ED

The LAPD protocol based on the line interfaces implemented (Annex LADP configuration)

01
3AL 97156 ACAA TQCVA

46/50

4 ANNEXES
4.1 Annex - Bi-directional protected cross-connection between a 2 Mbit/s port and STM-n
port

Figure 21 - E1 cross connect configuration


Procedure

1320CT

Select Configuration Cross Connection Management menu of the 1320CT window

F In the Cross Connection Management window, Click Create button


F In the Main Cross Connection window, select Type Bidirectional, Protection
Protected, choose Revertive, then click Input Choose button
In the Search for Cross Connection Input window, choose any one TU12 of MB Port#01,
then click OK button

F In the Main Cross Connection window, click Prot. Input Choose button
In the Search for Cross Connection Protection window, choose corresponding TU12 of MB
Port#02, then click OK button

F In the Main Cross Connection window, click Output Choose button


In the Search for Cross Connection Output window, choose any one VC12 of E1 board,
then click OK button

In the Main Cross Connection window, click OK button

F In the Cross Connection Management window, Click Search button to see the cross
connection realized.

N.B. For more detailed info, please refer to Operators Handbook

ED

01
3AL 97156 ACAA TQCVA

47/50

4.2 Annex - Bi-directional protected cross-connection between a 34 Mbit/s port and STMn port

Figure 22 - DS3 cross connect configuration


Procedure

1320CT

Select Configuration Cross Connection Management menu of the 1320CT window

F In the Cross Connection Management window, Click Create button


F In the Main Cross Connection window, select Type Bidirectional, Protection
Protected, choose Revertive, then click Input Choose button
In the Search for Cross Connection Input window, choose any one TU3 of MB Port#01, then
click OK button

F In the Main Cross Connection window, click Prot. Input Choose button
In the Search for Cross Connection Protection window, choose corresponding TU3 of MB
Port#02, then click OK button

F In the Main Cross Connection window, click Output Choose button


In the Search for Cross Connection Output window, choose any one VC3 of E3 board, then
click OK button

In the Main Cross Connection window, click OK button

F In the Cross Connection Management window, Click Search button to see the cross
connection realized.

N.B.

ED

For more detailed info, please refer to Operators Handbook

01
3AL 97156 ACAA TQCVA

48/50

4.3 Annex - Optical Parameter values

Table 7 - Parameters specified for STM-1 Optical Interface


CHARACTERISTICS
DIGITAL SIGNAL
Nominal bit rate
Application code (Table 1/G.957)
Operating wavelength range
TRANSMITTER AT REFERENCE POINT
S
Source type

UNIT
Kbit/s

nm

VALUE
STM-1 according to G.707 and G.958
155.520
S-1.1
L-1.1
L-1.2
1261-1360 1280-1335 1480-1580

MLM

MLM

SLM

dBm
dBm

-8
-15

0
-5

0
-5

Minimum sensitivity (BER 10-10)

dBm

In Ga As
PIN
-28

In Ga As
PIN
-34

In Ga As
PIN
-34

Minimum overload

dBm

-8

-10

-10

Mean launched power


-

maximum
minimum

RECEIVER AT REFERENCE POINT R


Type of detector

ED

01
3AL 97156 ACAA TQCVA

49/50

4.4 Annex - LAPD configuration


1642EM has four LAPD: LAPD1, LAPD2, LAPD3 and LAPD4, responding to No.1 & 2 optical port of main
control board and ECC channel of slot 2 &3 respectively.
1320CT
Select Configuration
Configuration menu

Comm/Routing

Interfaces

Configuration

LAPD

F In the LAPD Configuration window, Click Create button


F In the Create LAPD Interfaces window, select Choose button
In the TP Search window, choose RsTTP of MB Port#01 or Port#02, then click OK button

F In the Create LAPD Interfaces window, the LAPD Role choose Network or User, then
click OK

F If LAPD Role of Port#01 choose Network, then LAPD Role of Port#02 should choose
User, and vice versa
If optical model doesnt plug on main board, or slot 2 & 3 dont have OT1B1 board, relevant LAPD is
invalid.
Each LAPD has a LAPD Role attribute. For each LAPD, its Role can be configured to User Role or
Network Role.
Each LAPD has another attribute: ECC Channel. Main board and OT1B1 board have two options: RS and
MS, indicating the selections of ECC Channel are D1-D3, D4-D12.
Two NEs are connected by optical fiber. Under Role configuration, optical port of User Role must connect
with optical port of Network Role by optical fiber, thus User Role must respond one by one with Network Role.
Meanwhile, their ECC Channel must be exactly same.
LAPD configuration command is effective immediately.

END OF DOCUMENT

ED

01
3AL 97156 ACAA TQCVA

50/50

1. TEST REPORT SHEET MODULES


ON-SITE MULTISERVICE NODE FINAL TEST
SITE
_______________________________________
EQUIPMENT TYPE
_______________________________________
EQUIPMENT RELEASE
_______________________________________
SUBRACK Serial Number
_______________________________________
UNIT
TYPE
SERIAL NUMBER
SLOT 1
SLOT 2
SLOT 3
SLOT 4
SLOT 5

ON-SITE MULTISERVICE NODE FINAL TEST : LOCAL MEASUREMENTS


Measure
Expected Value and Tolerance Measured
Value
Free-running frequency check
+-4.6 ppm
Electrical ports check
2 Mbit/s
Multi-demultiplexing check and AIS
0 errors
forwarding to the ports.
Electrical ports Daisy Chain.
0 errors
34/45 Mbit/s
Multi-demultiplexing check and AIS
0 errors
forwarding to the ports.
Electrical ports Daisy Chain.
0 errors
10/100 Mbit/s ETHERNET
Local switch function and port status check.
0 errors
STM-1
Multi-demultiplexing check and AIS
forwarding to the ports.
Electrical ports Daisy Chain.
Optical ports test
N. port
PTx power test
Test error-free data
PTx power test
Test error-free data
PTx power test
Test error-free data
PTx power test
Test error-free data
PTx power test
Test error-free data
PTx power test
Test error-free data

ED

transit

transit

transit

transit

transit

transit

U.M.
ppm

errors
errors
errors
errors
errors

0 errors

errors

0 errors

errors

Type/
Slot
See annex 3
0 errors
See annex 3
0 errors
See annex 3
0 errors
See annex 3
0 errors
See annex 3
0 errors
See annex 3
0 errors

(*)
(*)
(*)
(*)
(*)
(*)

dBm
errors
dBm
errors
dBm
errors
dBm
errors
dBm
errors
dBm
errors

03
3AL 97156 ACAA TQCVA

1/2

ON-SITE MULTISERVICE NODE FINAL TEST : LOCAL MEASUREMENTS


Measure
Expected Value and Tolerance Measured
Value
SNCP protection check (Line posts)
check
Auxiliary channels check
V.24 RS232
0 errors
E2A
0 errors
F1A
0 errors
E2B
0 errors
F1B
0 errors
Free-running frequency check (stability)
+- 4.6 ppm
Alarm check
Remote alarms
INT
check
URG
check
NURG
check
TAND
check

ON-SITE MULTISERVICE NODE FINAL TEST : LOCAL MEASUREMENTS


Measure
Expected Value and Tolerance Measured
Value
Housekeeping alarms check:
HK-IN 1
check
HK-IN 2
check
HK-IN 3
check
HK-OUT 1
check
HK-OUT 2
check
HK-OUT 3
check

U.M.

errors
errors
errors
errors
errors
ppm

U.M.

END OF DOCUMENT

ED

03
3AL 97156 ACAA TQCVA

2/2

THIS PAGE MUST NOT BE INCLUDED IN THE HANDBOOK


MANUAL CODE HDBK P/N 3AL 97156 ACAA Ed.01 TQCVA

1642 Edge Multiplexer Rel.2.1


INSTALLATION HANDBOOK

ORIGINAL MSWORD: FILE ARCHIVE: cod ANV (PD1PD2)


-

Total number of pages for archivage: 2+54=56

ASSEMBLY INSTRUCTIONS
-

RECTO VERSO PRINTING


HANDBOOK COMPOSITION AND ASSEMBLY:
step

1
2
3
4

No pages
LABELS
FRONT
HANDBOOK
TEST REPORT

2
50
2

TOTAL A4 PAGES:
TOTAL A4 SHEETS:

54
27

WARNING FOR AUNITS OTHER THAN AITALY

Labels are done according to AItaly binder format.

Source file: MSWORD-OFFICE PROFESSIONAL 2000


The data below will be used for the labels:

1642 Edge Multiplexer Rel.2.1


.
STM-1 Multi-Service Edge Multiplexer
for Customer Premises
.
INSTALLATION HANDBOOK

3AL 97156 ACAA Ed.01 TQCVA

VOL. 1/1

1/2
3AL 97156 ACAA Ed.01 TQCVA

numbered
from
to

1/50

50/50

1642 Edge Multiplexer Rel.2.1


.
STM-1 Multi-Service Edge Multiplexer
for Customer Premises
.

INSTALLATION HANDBOOK
3AL 97156 ACAA Ed.01 TQCVA

VOL. 1/1
1642 Edge Multiplexer Rel.2.1
.
STM-1 Multi-Service Edge Multiplexer
for Customer Premises

INSTALLATION HANDBOOK
3AL 97156 ACAA Ed.01 TQCVA

VOL. 1/1
1642 Edge Multiplexer Rel.2.1
STM-1 Multi-Service Edge Multiplexer
for Customer Premises
.
3AL 97156 ACAA Ed.01 TQCVA - INSTALLATION HANDBOOK VOL. 1/1

1642 Edge Multiplexer Rel.2.1


STM-1 Multi-Service Edge Multiplexer
for Customer Premises
3AL 97156 ACAA Ed.01 TQCVA - INSTALLATION HANDBOOK VOL. 1/1

1642 Edge Multiplexer Rel.2.1


.
STM-1 Multi-Service Edge Multiplexer
for Customer Premises
.
3AL 97156 ACAA Ed.01 TQCVA - INSTALLATION HANDBOOK VOL. 1/1

END OF INTERNAL DOCUMENT1