Sunteți pe pagina 1din 2

Date:01/14/2015

STL Drilling Sdn. Bhd.


Reference:
Date:
Micropile Design

70 Ton Safe Working Load Micro-pile ( 250mm)


29-Nov-01

Johnny Then- Design Micropile calculation - Copy right 10/10/2001 Call Johnny Then 019-8203432

Working Load =

70

(Tonnes)

30.00
0.45 - 0.50
26.60

N/mm2, fcu

A) Material Properties
1) Grout
Compressive Strength At 28 days =
Water Cement Ratio =
Yong's Modulus Ec =

KN/mm2

Johnny Then- Design Micropile calculation - Copy right 10/10/2001 Call Johnny Then 019-8203432

B) Pipe Reinforcement / API Casing


Reinforcement =

7T25

Diameter of Steel Bar=

25.00

mm

Numbers of steel bar=

numbers

Area Of Steel bar =

3436.12

mm2

Designed Yield Strength, fy =

460.00

N/mm2

Johnny Then- Design Micropile calculation - Copy right 10/10/2001 Call Johnny Then 019-8203432

Young's Modulus, Est =

205.00

KN/mm2

C) Ultimate Load
Structural Capacity - Axial Bearing Capacity.
Method 1. Based On BS. 5400, Clause 11.3.7,
Ultimate Strength Of Axially Loaded Concrete
Filled Circular Hollow Steel Section.

Pult = 0.91 Ast f'y + 0.45 Ac fcc.


Pult = Ultimate Capacity of Pile
Ast = Area of High Tensile steel bars
fy is a reduced Nominal Yield Strength of Steel Bar, Given by fy = C2fy.
Ac = Nett Grout Area.
fcc is an Enhanced Characteristic of Triaxial Contained Concrete Under Axial Load, Given by
cl and c2 are constant given in Table 12 BS5400.
Single Le/Do Always More than 25, thus, c1 = 0.0 and c2 = 1.0.
Hence, Pult = 0.91 Ast fy + 0.45 Ac fcu.

1 of 2

Date:01/14/2015

STL Drilling Sdn. Bhd.

For Working Load Of =


Borehole Diameter, Db =
Gross Area, Ag =
Area of Grout Ac =

70.0
250.00
49087.39
45651.27

Required Safety Factor =

>>> Pult 1 =
Factor of Safety =

205.47

Tonnes
mm
mm2
mm2

Tonnes

2.9

(O.K.)

Johnny Then- Design Micropile calculation - Copy right 10/10/2001 Call Johnny Then 019-8203432

Method 2. Based on Safe Load Of Steel Reinforcement Itself.


Ultimate Capacity, Pult =
>> =
Factor Of Safety

fy As
158.06

Tonnes

2.3

From The Method 2, The Minimium Safety Factor is 1.0 and The Maximum Safety
Of Factor is 2.0
Johnny Then- Design Micropile calculation - Copy right 10/10/2001 Call Johnny Then 019-8203432

Hence, the Structural Capacity is O.K

Johnny Then- Design Micropile calculation - Copy right 10/10/2001 Call Johnny Then 019-8203432

(O.K.)

2 of 2