Sunteți pe pagina 1din 2

INSTRUCTIONAL MANUAL

PSMR1

1. Phase rotation input terminal

Phase Sequence & Motor Rotation

4. Altitude up to 6560 feet (2000 meters).


5. Relative humidity 80% Max.
6. Ambient temperature 32 - 104F (0 - 40C).

2. Open phase indicator


3. Phase rotation indicator

Observe the international electrical symbols


listed below:

4. Motor tester power switch


5. Motor tester power indicator

Meter is protected throughout by double


insulation or reinforced insulation.

6. Motor rotation indicator

WARNING! Risk of electric shock.

7. Motor rotation input terminal

CAUTION! Refer to this manual before


using the meter.

Measuring Methods

Alternating current.

Operations 3 phase rotation tester:


1. Connect the test lead to 3-phase input
terminals by R-S-T.

Features
Three functions in one unit including open phase,
phase sequence and motor rotation indication.
This model is ideal for installing conveyor lines,
pump systems and interconnected drivers.
Identifies 3-phase sequence and open phase check.
Battery operated.

1-800-547-5740 Fax: (503) 643-6322


www.ueitest.com email: info@ueitest.com

Complete with three large alligator clips.

Continued on other side

Descriptions

UE

All the information you need in one device. Verify


correct wiring to avoid damage.
1

Read the following safety information


carefully before attempting to operate or
service the meter.
Use the meter only as specified in this
manual; otherwise the protection provided
by the meter may be impaired.
Rated environmental conditions:
1. Indoor use.
2. Installation Category III.
3. Pollution Degree 2.

PSMR1

Phase & Motor Rotation Tester

Limited Warranty
2

The PSMR1 is warranted to be free from defects in


materials and workmanship for a period of three years
from the date of purchase. If within the warranty period
your instrument should become inoperative from such
defects, the unit will be repaired or replaced at UEis
option. This warranty covers normal use and does not
cover damage which occurs in shipment or failure which
results from alteration, tampering, accident, misuse,
abuse, neglect or improper maintenance. Batteries and
consequential damage resulting from failed batteries are
not covered by warranty.

Note: Follow all warnings to ensure


safe operations.

Safety Notes

3. Make sure that all of the three lamps for


open phase check are on. If so, there is no
open phase. When any of the three lamps
is not on, there is open phase.

Meets EN61010-1 safety requirements.

Introduction

Use the PSMR1 to check supply line phase


orientation for devices such as scroll
compressors or motors. Works on 45-70 Hz
and on voltages between 100 and 600 VAC.
Five indicators give you information about
open phases, and indicate the sequence of the
three lines. Use the motor rotation tester side
of the meter to verify the rotation direction of
the motor shaft.

2. Connect color alligator clips to the


terminals of a 3-phase power source.
Connecting order may be optional.

5
6

Any implied warranties, including but not limited to


implied warranties of merchantability and fitness for
a particular purpose, are limited to the express
warranty. UEi shall not be liable for loss of use of
the instrument or other incidental or consequential
damages, expenses, or economic loss, or for any claim
or claims for such damage, expenses or economic loss.
A purchase receipt or other proof of original purchase
date will be required before warranty repairs will be
rendered. Instruments out of warranty will be repaired
(when repairable) for a service charge. Return the unit
postage paid and insured to:

1-800-547-5740 FAX: (503) 643-6322


Service: (800) 308-7709
www.ueitest.com Email: info@ueitest.com
This warranty gives you specific legal rights. You may also
have other rights which vary from state to state.
Copyright 2003 UEi

PSMR1-MAN 7/03

Open phase
check lamp R
is not on

Maintenance

Open phase on
terminal where RED
alligator clip
is connected

Open phase
check lamp S
is not on

Open phase on
terminal where
YELLOWalligator
is connected

Open phase
check lamp T
is not on

Open phase on
terminal where
BLUE alligator clip is
connected

Battery Replacement:
1. It is necessary to replace battery, when
green lamp is dull.
2. Use a screwdriver to unscrew the screws on
the back. Open the case (Fig. 2), take out the
battery and replace with new battery type
(DC 9V alkaline battery).
3. Reinstall the case.
Fuse Replacement:
1. It is necessary to replace the fuse when the
lamp indicator R or T show no connection
and change R-S-T is the same.

4. Check the rotating direction of the


rotation indicator if:

Lamp of counter
clockwise is lit

Lamp of
clockwise is lit

2. Use a screwdriver to unscrew the screws on


the back. Open the case (Fig. 2), take out
the damaged fuse and replace with a new
fuse (200mA, 250V).

Alternate the
connection of two of
the three
alligator clips
Phase sequence is R,
S, and T in order of
the power source
terminals where the
RED, YELLOW and
BLUE alligator clips
are connected

Operating motor rotation tester:


1. Make sure there is no voltage present.
2. Connect the test lead to motor input
terminal by L1 - L2 - L3, and press the
power button (Fig 1). The power
indicator green lamp is lit. (If red lamp of
clockwise or counter clockwise is lit before
rotating the motor shaft, it means there is
voltage present. Please stop measuring,
take off the test leads and turn off the
external power). If red lamp is lit while
rotating the motor shaft clockwise, it
means 3-phase motor connection to the
power supply by L1 - L2 - L3, the 3-phase
motor will rotate clockwise.
3. Connect the lead to 3-phase motor by
L1 - L2 - L3, and press the power button on.
The power indicator green lamp is lit.
Rotating the motor shaft counter clockwise.
If red lamp of counter clockwise is lit. it
means 3-phase motor connection to the
power supply by L1 - L2 - L3, the 3-phase
motor will rotate clockwise.

(Fig 1)

3. Reinstall the case.

4. If you require the motor to rotate counter


clockwise, you should change connection to
L2 - L1 - L3, the motor should now rotate
counter clockwise.

Specifications
Input Voltage:

100V AC up to 600V
AC max

Frequency Range:

45 to 70 Hz

Circuit Structure:

All electronic (not


mechanical)

Power Requirement:

DC 9V alkaline battery

Power Consumption:

Consumption current
approx. 14mA of
motor rotation field
of tester. AC power
consumption approx.
7mA per phase
rotation field of
indicator.

Installation Category:

EN61010-1 600V
CAT III

Dimension:

6.02 (L) x 2.83 (W)


x 1.37 (H)
153mm x 72mm x
35mm

Weight:

Approx. 182g
including battery

Accessories:

Test leads (red,


yellow and blue),
soft carrying case,
instruction manual

(Fig 2)

Cleaning and Storage:


WARNING!
To avoid electrical shock or damage to the meter,
do not get water inside the case.
Periodically wipe the case with a damp cloth and
detergent; do not use abrasives or solvents.
If the meter is not to be used for periods of
longer than 60 days, remove the battery and
store them separately.

S-ar putea să vă placă și