Safe energy control, switching and control in industrial settings, buildings and machinery
construction: innovative protection concept coupled with diagnostic and communication
functions make it possible.
The NZM circuit-breaker assortment offers an interface for the SmartWire-Darwin
communication system.
Page 17/140
Model series NZM1 NZM4
Only four compact switches cover all applications +++ 3- and 4-pole +++ Flexible mounting
through modular functions groups +++ Complete nominal current up to 50 C ambient
temperature +++ Suitable for use worldwide Page 17/4
Door coupling rotary handles
Very wide range of variants for each application +++ All applications have identical drilling
template +++ Automatic centering +++ Shaft support for years of operational safety +++
Sidewall installation for space-saving main switch installation Page 17/118
Standard auxiliary contacts, trip-indicator auxiliary contacts from the Eaton command
device program.
Favorably priced identical parts from the Titan program reduce variety of types and
stockkeeping +++ Installation from front to same position +++ Easy clip-in reduces assembling
costs Page 17/106
Remote operators
Unified functions concept for all variants +++ Small closing delays from 60 100 ms +++
Can be locked and sealed to provide safety Page 17/134
1.1
System overview
Circuit-breakers, switch-disconnectors 3/4 pole ................................................................................................. 4
1.2
1.3
System overviewOrdering
Circuit-breakers, thermomagnetic releases pole .............................................................................................. 83
Circuit-breakers, magnetic short-circuit releases, 3 pole .................................................................................. 18
Circuit-breakers, electronic releases, 3 pole ..................................................................................................... 22
Circuit-breakers, thermomagnetic releases, 4 pole .......................................................................................... 28
Circuit-breakers, electronic releases, 4 pole ..................................................................................................... 36
Switch-disconnectors, 3 pole ........................................................................................................................... 42
Switch-disconnectors, 4 pole ........................................................................................................................... 44
Circuit-breakers for 1000 V AC, 3 pole ............................................................................................................. 46
Switch-disconnectors for 1000 V DC, 2 pole .................................................................................................... 49
Switch-disconnectors in ATEX type .................................................................................................................. 50
1.4
1.5
System overviewOrdering
Circuit-breakers UL/CSA, IEC, thermomagnetic releases, 3 pole ..................................................................... 54
Circuit-breakers UL/CSA, IEC, magnetic short-circuit releases, 3 pole ............................................................. 72
Circuit-breakers UL/CSA, IEC, electronic releases, 3 pole ................................................................................ 64
Circuit-breakers UL/CSA, IEC, thermomagnetic releases, 4 pole ..................................................................... 78
Molded case switches for North America ........................................................................................................ 80
1.6
System overviewOrdering
Terminals .......................................................................................................................................................... 82
Plug-in units, withdrawable units .................................................................................................................... 105
Auxiliary contacts ............................................................................................................................................ 106
Undervoltage releases .................................................................................................................................... 108
Shunt releases ................................................................................................................................................ 114
Door coupling rotary handles .......................................................................................................................... 118
Door coupling rotary handles for North America ............................................................................................ 120
Rotary handles with door interlock ................................................................................................................. 123
Main switch assembly kit ............................................................................................................................... 124
Accessories .................................................................................................................................................... 127
Mechanical interlock ....................................................................................................................................... 130
Paralleling mechanism .................................................................................................................................... 131
Multifunction component adapter .................................................................................................................. 122
Remote drive .................................................................................................................................................. 134
Earth-fault release ........................................................................................................................................... 135
Earth-fault release, residual-current relay ....................................................................................................... 137
Diagnostics, energy metering, communication .............................................................................................. 138
SmartWire-DT communication module .......................................................................................................... 140
Insulated enclosures ....................................................................................................................................... 142
1.7
Engineering
Selectivity: incoming circuit-breaker, outgoing circuit-breaker ........................................................................144
Cable protection, back-up protection .............................................................................................................. 148
Direction of blow-out, minimum clearances, tube cable lugs ......................................................................... 149
Auxiliary contacts, trip-indicating auxiliary contacts ........................................................................................ 150
Mechanical interlock for (door-coupling) rotary handles ................................................................................. 151
Mechanical interlock for remote operator, residual-current relay ................................................................... 152
Remote operator, main switch assembly kit, terminals ................................................................................. 153
Tripping characteristic ..................................................................................................................................... 154
Let-through characteristics ..............................................................................................................................158
Residual-current release of the frequency response ...................................................................................... 164
1.8
Technical data
Circuit-breakers, switch-disconnectors ........................................................................................................... 165
Circuit breakers ............................................................................................................................................... 166
Circuit-breakers, switch-disconnectors for 1000 V ......................................................................................... 168
Switch-disconnectors ..................................................................................................................................... 169
Moulded case switches .................................................................................................................................. 170
Current limiting values, weights ..................................................................................................................... 171
Temperature dependency, thermomagnetic release ..................................................................................... 172
Temperature dependency, electronic release ................................................................................................ 173
Active power loss ........................................................................................................................................... 174
Terminal capacities ......................................................................................................................................... 176
Switch-disconnectors for 1000 V, bridge kits: temperature dependency ....................................................... 178
Auxiliary contacts, equipping time differences ............................................................................................... 179
Undervoltage release, shunt release, capacitor unit ....................................................................................... 180
Remote operator, residual-current relay ......................................................................................................... 181
Residual-current releases ............................................................................................................................... 182
Data management interface (DMI module) .................................................................................................... 183
Fieldbus connection ........................................................................................................................................ 184
SmartWire-DT communication module .......................................................................................................... 186
Measuring and communication module ......................................................................................................... 188
1.9
Dimensions
Construction size 1: basic devices .................................................................................................................. 189
Construction size 1: accessories .....................................................................................................................190
Construction size 2: basic devices .................................................................................................................. 198
Construction size 2: accessories .................................................................................................................... 199
Construction size 3: basic devices ................................................................................................................. 210
Construction size 3: accessories .................................................................................................................... 211
Construction size 4: basic devices ................................................................................................................. 220
Construction size 4: accessories .................................................................................................................... 221
Measuring and communication module ......................................................................................................... 233
SmartWire-DT communication module .......................................................................................................... 233
1.1
Circuit-breakers, switch-disconnectors
Auxiliary contacts, trip-indicating auxiliary contacts
System overview
7
1 NZM
37
5
10
4
3
11
12
36
1
35
31
13
32
34
14
33
15
18
30
17
29
16
28
27
26
23
20
19
25
21
ATEX
24
38
22
Circuit-breakers, switch-disconnectors
Basic devices
1.1
Basic devices
1
Rated uninterrupted current up to
1600A
Switching capacity 25, 36, 50, 150
kA at 415 V
Adjustable releases for overload
and short-circuit
Adjustable time selectivity
Protection of systems, cables,
motors, generators
3 and 4 pole; IEC/EN 60947
Page 8
Voltage releases
Undervoltage releases
Shunt releases
Page 108
15
Insulated enclosures
38
Safety switches (maintenance
and manual override switches)
approved for use in potentially
explosive areas in Zone 22.
Degree of protection IP66
ATEX
Switch-disconnectors
Rated uninterrupted current up
to 1600 A
Can be tripped remotely with
undervoltage or shunt release
3 and 4 pole; IEC/EN 60947
Page 42
Circuit-breakers for
1
North America
Rated uninterrupted current up
to 1200 A
Switching capacity 25, 35,
100 kA at 480 V
Adjustable release for
overload and short-circuit
Adjustable time selectivity
Protection of systems, cables,
motors, generators
3 and 4 pole, UL 489/CSA 22.2
no. 5.1, IEC/EN 60947
Page 54
Molded case switches for
1
North America
Rated uninterrupted current up
to 1200 A
Can be tripped remotely with
undervoltage or shunt release
3 pole, UL489/CSA 22.2 no. 5.1
Page 80
Rear-mounted drives
Page 127
18
handles
Lockable
With door interlock
20
22
Page 118
15
Page
106
36
Page 125
Extension shaft
Can be cut to required length
21
Mounting accessories
9
23
Connection width
extensions
NZM3 Page 92
NZM4 Page 103
Control cable terminals
For two terminal locations at
top or bottom
NZM1 Page 84
NZM2 Page 88
NZM3 Page 84
NZM4 Page 104
Box terminals
Standard equipment on
construction size 1
Flush mounting within the
switch housing
NZM1 Page 82
NZM2 Page 86
NZM3 Page 92
Page 118
Rotary handles
Lockable
Page 122
26
Residual-current protection 17
device
Page 135
Toggle lever locking device 27
Page 129
Side operator handle
Page 128
28
Mechanical interlocks
Page 130
29
Page 106
Early-make auxiliary
contacts
For interlock and
load-shedding circuits
Page 141
PROFIBUS-DP interface
Page 139
Page 134
Display
Connectable to modules
NZMXMC-MB
With templates for viewing
XMC readings
Indication of min. and max.
values
Terminal covers
Protection against direct
contact where cable lugs, bars
or tunnel terminals are used
NZM1 Page 84
NZM2 Page 88
NZM3 Page 98
30zz
NZM4 Page 104
Communication module
33
NZM for SmartWire-Darwin
For reading status data,
current values, switch model
and set values
16
Remote operators
For remote switching of
circuit-breakers and switchdisconnectors
Add-on functions
Trip-indicating auxiliary
contacts (HIA)
General trip indication '+',
when tripped by voltage
release, overload release or
short-circuit release
Page 142
Measuring and
communication module
For reading current, voltage,
power and energy
MODBUS interface on board
Page 141
Terminal covers,
knockout
NZM1 Page 84
NZM2 Page 88
NZM3 Page 98
NZM4 Page 104
Clips
NZM1-XC35 for 35-mmtop-hat rail
NZM2-XC75 for 75-mmtop-hat rail
Page 129
11
Busbar adapters
Page 132
12
13
10
Insulating surround
For toggle levers, rotary
mechanisms and remote
operators
Page 129
24
25
Spacers
Page 129
14
Page 140
1.2
1
Circuit-breakers, switch-disconnectors
Auxiliary contacts, trip-indicating auxiliary contacts
Thermomagnetic releases
System cable protection
Iu
A
Iu
A
Io
A
Ir
A
Ii
A
Iu
A
Iu
A
Ir
A
Ii
A
20
25
32
40
50
63
80
100
100
100
100
125
160
200
250
320
400
500
NZMB1-A...
25
0.25
25
0.25
NZMC1-A...
36
0.25
30
0.25
12
0.5
8
0.5
NZMN1-A...
50
0.25
35
0.25
20
0.30
10
0.50
NZMH1-A...
100 0.20
35
0.25
20
0.30
10
0.50
20
25
32
40
50
63
80
100
100
100
100
125
160
200
250
320
400
500
NZMB2-A...
25
0.25
25
0.25
NZMC2-A...
36
0.25
30
0.25
12
0.5
8
0.5
NZMN2-A...
50
0.25
35
0.25
20
0.25
10
0.30
NZMH2-A...
150 0.20
130 0.20
50
0.25
20
0.30
20
25
32
40
50
63
80
100
100
100
100
125
160
200
250
320
400
500
0.8 - 1xIn
0.8 - 1xIn
0.8 - 1xIn
0.8 - 1xIn
0.8 - 1xIn
0.8 - 1xIn
0.8 - 1xIn
0.8 - 1xIn
0.8 - 1xIn
0.8 - 1xIn
0.8 - 1xIn
0.8 - 1xIn
0.8 - 1xIn
0.8 - 1xIn
0.8 - 1xIn
0.8 - 1xIn
0.8 - 1xIn
0.8 - 1xIn
350
350
350
8 - 10xIn
6 - 10xIn
6 - 10xIn
6 - 10xIn
6 - 10xIn
6 - 10xIn
6 - 10xIn
6 - 10xIn
6 - 10xIn
6 - 10xIn
20
25
32
40
50
63
80
100
20
25
32
40
50
63
80
100
0.8 -1xIn
0.8 -1xIn
0.8 -1xIn
0.8 -1xIn
0.8 -1xIn
0.8 -1xIn
0.8 -1xIn
0.8 -1xIn
0.8 -1xIn
0.8 -1xIn
0.8 -1xIn
0.8 -1xIn
0.8 -1xIn
0.8 -1xIn
0.8 -1xIn
0.8 -1xIn
0.8 -1xIn
0.8 -1xIn
350
350
10 - 14xIn
8 - 14xIn
8 - 14xIn
8 - 14xIn
8 - 14xIn
NZM1:
Notes
Motor protection
NZMC3-A...
36
0.25
30
0.25
12
0.5
8
0.5
NZMN3-A...
50
0.25
35
0.25
20
0.25
10
0.30
NZMH3-A...
150 0.20
130 0.20
65
0.20
35
0.25
125
160
200
NZM1:8xIn
6 - 10xIn
6 - 10xIn
6 - 10xIn
6 - 10xIn
NZMB2-M...
25
0.25
25
0.25
NZMB2-M...
25
0.25
25
0.25
NZMB2-M...
50
0.25
35
0.25
20
0.30
10
0.50
NZMB2-M...
50
0.25
35
0.25
20
0.25
10
0.30
NZMH2-M...
150 0.20
130 0.20
50
0.25
20
0.30
8 12.5xIn
NZM2:
8 14xIn
8 14xIn
8 14xIn
8 14xIn
8 14xIn
8 14xIn
8 14xIn
8 14xIn
The stated switching capacity values are rated ultimate short-circuit breaking
capacities (Icu)
Switch-disconnectors
With main switch characteristics to IEC/EN 60204 and VDE 0113
Isolating characteristics to IEC/EN 60947, VDE 0660
without overload and short-circuit release
kA
kA
63 - 160
PN1-... PN1-...
2.8
2.8
2
2
160 - 250
PN1-... PN1-...
2.8
2.8
2
2
400 - 630
PN1-... PN1-...
2.8
2.8
2
2
630 - 1600
PN1-... PN1-...
2.8
2.8
2
2
1.2
Circuit-breakers, switch-disconnectors
Mechanical interlock for (door-coupling) rotary handles
Electronic releases
Systems,cable, selectivity and generator protection
Iu
A
Iu
A
100
160
250
250
400
630
Io
A
630
800
1000
1250
1600
Motor protection
Ir
A
Ii
A
Iu
A
Iu
A
Ir
A
Ii
A
0.5 - 1 x In
2 - 10 x Ir
2 - 12 x In
0.5 - 1 x In
2 - 14 x Ir
2 - 6 x Ir
2 - 8 x Ir
90
140
220
350
450
550
875
1400
NZMN2-ME...
50
0.25
35
0.25
25
0.25
20
0.30
NZMH2-ME...
150 0.20
130 0.20
50
0.25
20
0.30
NZMN3-ME...
50
0.25
35
0.25
25
0.25
20
0.30
NZMH3-ME...
150 0.20
130 0.20
65
0.20
35
0.30
NZMN4-ME...
50
0.25
35
0.25
25
0.25
20
0.30
NZMH4-ME...
851) 0.20
85
0.20
65
0.20
50
0.25
NZMN2-...E...
NZMN3-...E...
NZMN4-...E...
50
0.25
50
0.25
50
0.25
35
0.25
35
0.25
35
0.25
25
0.25
25
0.25
25
0.25
20
0.30
20
0.30
20
0.30
NZMH2-...E...
NZMH3-...E...
NZMH4-...E...
150 0.20
150 0.20
851) 0.20
130 0.20
130 0.20
85
0.20
50
0.25
65
0.20
65
0.20
20
0.30
35
0.30
50
0.25
A selection of approved circuit-breakers and switch-disconnectors for world-wide usePage 17/54
1)For higher switching capacity please inquire
1.3
1
Circuit-breakers, switch-disconnectors
Auxiliary contacts, trip-indicating auxiliary contacts
Ordering
NZM...A
Switching capacity
400/415 V 50/60 Hz
Rated current =
Rated uninterrupted
current
Setting range
Overload releases
I cu
In=Iu
Ir
kA
Short-circuit releases
Non-delayed
Fixed mounting
with screw terminals
Part no.
Article no.
Price
See price
list
Ii=In X ...
I
System and cable protection
Basic switching
capacity
Basic switching
capacity
Comfort switching
capacity
25
25
36
20
15-20
350A fixed
20-25
350A fixed
32
25-32
350A fixed
40
32-40
8-10
50
40-50
6-10
63
50-63
6-10
80
63-80
6-10
100
80-1000
6-10
125
100-125
6-10
160
125-160
1280 A fixed
160
125-160
6-10
200
160-200
6-10
250
200-250
6-10
300
240-300
6-10
20
15-20
350A fixed
20-25
350A fixed
32
25-32
350A fixed
40
32-40
8-10
50
40-50
6-10
63
50-63
6-10
80
63-80
6-10
100
80-1000
6-10
125
100-125
6-10
160
125-160
1280 A fixed
Screw terminals as
accessories
NZMB2-A160
259088
NZMB2-A200
259089
NZMB2-A250
259090
NZMB2-A300
107518
Screw terminals as
accessories
S
S
S
S
Circuit-breakers, switch-disconnectors
Mechanical interlock for (door-coupling) rotary handles
1.3
1
Fixed mounting
with screw terminals
Part no.
Article no.
Plug-in units
Part no.
Article no.
Price
See price
list
Price
See price
list
Std.
pack
Notes
Order base
separately
B = box terminals
S = screw terminals
For further terminal types see
accessories
NZMB1-A20
280987
NZMB1-A25
280988
NZMB1-A32
280989
NZMB1-A40
259075
NZMB1-A50
259076
NZMB1-A63
259077
NZMB1-A80
259078
NZMB1-A100
259079
NZMB1-A125
259080
NZMB1-A160
281230
NZMB2-A160-BT
110215
NZMB2-A200-BT
110216
NZMB2-A250-BT
110217
NZMB2-A300-BT
110214
NZMC1-A20
283293
NZMC1-A25
283294
NZMC1-A32
283295
NZMC1-A40
271392
NZMC1-A50
271393
NZMC1-A63
271394
NZMC1-A80
271395
NZMC1-A100
271396
NZMC1-A125
271397
NZMC1-A160
283296
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
NZMB1-A20-SVE
112733
NZMB1-A25-SVE
112734
NZMB1-A32-SVE
112735
NZMB1-A40-SVE
112703
NZMB1-A50-SVE
112704
NZMB1-A63-SVE
112705
NZMB1-A80-SVE
112706
NZMB1-A100-SVE
112707
NZMB1-A125-SVE
112708
1 off
IEC/EN 60947-2
1 off
IEC/EN 60947-2
NZMB2-A160-SVE
113193
NZMB2-A200-SVE
113194
NZMB2-A250-SVE
113195
NZMC1-A20-SVE
112753
NZMC1-A25-SVE
112754
NZMC1-A32-SVE
112755
NZMC1-A40-SVE
112737
NZMC1-A50-SVE
112738
NZMC1-A63-SVE
112739
NZMC1-A80-SVE
112740
NZMC1-A100-SVE
112741
NZMC1-A125-SVE
112742
Circuit-breakers, switch-disconnectors
1.3
NZM...A
1
Switching capacity
400/415 V 50/60 Hz
Rated current =
Rated uninterrupted
current
Setting range
Overload releases
I cu
In=Iu
Ir
kA
Short-circuit releases
Non-delayed
Fixed mounting
with screw terminals
Part no.
Article no.
Price
See price
list
Ii=In X ...
I
System and cable protection
Comfort switching
capacity
36
36
Normal switching
capacity
50
50
50
10
160
125-160
6-10
200
160-200
6-10
250
200-250
6-10
300
240-300
320
NZMC2-A160
271421
NZMC2-A200
271422
NZMC2-A250
271423
6-10
NZMC2-A300
107519
250-320
6-10
400
320-400
6-10
500
400-500
6-10
NZMC3-A320
109665
NZMC3-A400
109666
NZMC3-A500
109667
20
20-25
350 A fix de
25
20-25
350 A fixde
32
25-32
350 A fixde
40
32-40
8-10
50
40-50
6-10
63
50-63
6-10
80
63-80
6-10
100
80-100
6-10
125
100-125
6-10
160
125-160
1280 A fixde
160
125-160
6-10
200
160-200
6-10
250
200-250
6-10
300
240-300
6-10
320
250-320
6-10
400
320-400
6-10
500
400-500
6-10
S
S
S
S
Screw terminals as
accessories
NZMN2-A160
259092
NZMN2-A200
259093
NZMN2-A250
259094
NZMN2-A300
107580
NZMN3-A320
109669
NZMN3-A400
109670
NZMN3-A500
109671
S
S
S
S
S
S
S
Circuit-breakers, switch-disconnectors
Mechanical interlock for (door-coupling) rotary handles
1.3
1
Fixed mounting
with screw terminals
Part no.
Article no.
Plug-in units
Price
See price
list
Part no.
Article no.
Price
See price
list
Std.
pack
Notes
Order base
separately
B = box terminals
S = screw terminals
For further terminal types see
accessories
NZMC2-A160-BT
110219
NZMC2-A200-BT
110280
NZMC2-A250-BT
110281
NZMC2-A300-BT
110218
NZMC3-A320-BT
110299
NZMC3-A320-AVE
113509
NZMC3-A400-BT
110300
NZMC3-A500-BT
110301
NZMC3-A320-AVE
113510
NZMC3-A500-AVE
113511
NZMN1-A20
281231
NZMN1-A25
281232
NZMN1-A32
281233
NZMN1-A40
259081
NZMN1-A50
259082
NZMN1-A63
259083
NZMN1-A80
259084
NZMN1-A100
259085
NZMN1-A125
259086
NZMN1-A160
281234
NZMN2-A160-BT
110283
NZMN2-A200-BT
110284
NZMN2-A250-BT
110285
NZMN2-A300-BT
110282
NZMN3-A320-BT
110302
NZMN3-A400-BT
110303
NZMN3-A500-BT
110304
NZMN2-A320-AVE
110858
NZMN3-A400-AVE
110859
NZMN3-A500-AVE
110860
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
NZMC2-A160-SVE
113220
NZMC2-A200-SVE
113221
NZMC2-A250-SVE
113222
NZMN1-A20-SVE
112776
NZMN1-A25-SVE
112777
NZMN1-A32-SVE
112778
NZMN1-A40-SVE
112757
NZMN1-A50-SVE
112758
NZMN1-A63-SVE
112759
NZMN1-A80-SVE
112760
NZMN1-A100-SVE
112761
NZMN1-A125-SVE
112762
1 off
IEC/EN 60947-2
1 off
IEC/EN 60947-2
NZMN2-A160-SVE
113244
NZMN2-A200-SVE
113245
NZMN2-A250-SVE
113246
11
Circuit-breakers, switch-disconnectors
1.3
NZM...A
1
Switching capacity
400/415 V 50/60 Hz
Rated current =
Rated uninterrupted
current
Setting range
Overload releases
I cu
In=Iu
Ir
kA
Short-circuit releases
Non-delayed
Fixed mounting
with screw terminals
Part no.
Article no.
Price
See price
list
Ii=In X ...
I
System and cable protection
High switching
capacity
100
150
150
12
20
15-20
350 A fix de
25
20-25
350 A fix de
32
25-32
350 A fix de
40
32-40
8-10
50
40-50
6-10
63
50-63
6-10
80
63-80
6-10
100
80-100
6-10
125
100-125
6-10
160
125-160
1280 A fix de
20
15-20
350 A fix de
25
20-25
6-10
32
25-32
350 A fixde
40
32-40
8-10
50
40-50
6-10
63
50-63
6-10
80
63-80
6-10
100
80-100
6-10
125
100-125
6-10
160
125-160
6-10
200
160-200
6-10
250
200-250
6-10
300
240-300
6-10
320
250-320
6-10
400
320-400
6-10
500
400-500
6-10
Screw terminals as
accessories
NZMH2-A20
281281
NZMH2-A25
281282
NZMH2-A32
281283
NZMH2-A40
259095
NZMH2-A50
259096
NZMH2-A63
259097
NZMH2-A80
259098
NZMH2-A100
259099
NZMH2-A125
259100
NZMH2-A160
259101
NZMH2-A200
259102
NZMH2-A250
259103
NZMH2-A300
107581
NZMH3-A320
109673
NZMH3-A400
109674
NZMH3-A500
109675
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Circuit-breakers, switch-disconnectors
Mechanical interlock for (door-coupling) rotary handles
1.3
1
Fixed mounting
with screw terminals
Part no.
Article no.
Plug-in units
Price
See price
list
Part no.
Article no.
Price
See price
list
Std.
pack
Notes
Order base
separately
B = box terminals
S = screw terminals
For further terminal types see
accessories
NZMH1-A20
284376
NZMH1-A25
284377
NZMH1-A32
284378
NZMH1-A40
284379
NZMH1-A50
284410
NZMH1-A63
284411
NZMH1-A80
284412
NZMH1-A100
284413
NZMH1-A125
284414
NZMH1-A160
284415
NZMH2-A20-BT
110296
NZMH2-A25-BT
110297
NZMH2-A32-BT
110298
NZMH2-A40-BT
110287
NZMH2-A50-BT
110288
NZMH2-A63-BT
110289
NZMH2-A80-BT
110290
NZMH2-A100-BT
110291
NZMH2-A125-BT
110292
NZMH2-A160-BT
110293
NZMH2-A200-BT
110294
NZMH2-A250-BT
110295
NZMH2-A250-BT
110286
NZMH3-A320-BT
110305
NZMH3-A400-BT
110306
NZMH3-A500-BT
110307
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
NZMH1-A20-SVE
112795
NZMH1-A25-SVE
112796
NZMH1-A32-SVE
112797
NZMH1-A40-SVE
112798
NZMH1-A50-SVE
112799
NZMH1-A63-SVE
112800
NZMH1-A80-SVE
112801
NZMH1-A100-SVE
112802
NZMH1-A125-SVE
112803
1 off
IEC/EN 60947-2
NZMH2-A20-SVE
113351
NZMH2-A25-SVE
113352
NZMH2-A32-SVE
113353
NZMH2-A40-SVE
113328
NZMH2-A50-SVE
113329
NZMH2-A63-SVE
113330
NZMH2-A80-SVE
113331
NZMH2-A100-SVE
113332
NZMH2-A125-SVE
113333
NZMH2-A160-SVE
113334
NZMH2-A200-SVE
113335
NZMH2-A250-SVE
113336
NZMH3-A320-AVE
110861
NZMH3-A320-AVE
110862
NZMH3-A500-AVE
110863
13
1.3
Circuit-breakers, switch-disconnectors
Auxiliary contacts, trip-indicating auxiliary contacts
NZM...M
Fixed mounting
with screw terminals
Switching
capacity
400/415 V
50/60 Hz
Rated current =
Rated
uninterrupted
current
Setting range
I cu
kA
In=Iu
A
Ir
A
Overload
releases
Rated operational
power
AC-3
50/60 Hz
Rated operational
current
400V
P
W
400V
Ie
A
8-14
18.5
36
Short-circuit
releases
Non-delayed
Ii=In X ...
Price
See price
list
Part no.
Article no.
I
Basic
switching
capacity
Motor protection
NZM...1-M...: with phase failure sensitivity
Tripping class 10 A
25
40
32-40
25
Comfort
switching
capacity
36
36
Normal
switching
capacity
50
50
14
50
40-50
8-14
22
41
63
50-63
8-14
30
55
80
63-80
8-14
37
68
100
80-100
8-12.5
45
81
125
100-125
8-14
45
99
160
125-160
8-14
75
134
200
160-200
8-14
110
196
40
32-40
8-14
18.5
36
50
40-50
8-14
22
41
63
50-63
8-14
30
55
80
63-80
8-14
37
68
100
80-100
8-12.5
45
81
125
100-125
8-14
45
99
160
125-160
8-14
75
134
200
160-200
8-14
110
196
40
32-40
8-14
18.5
36
50
40-50
8-14
22
41
63
50-63
8-14
30
55
80
63-80
8-14
37
68
100
80-100
8-12.5
45
81
125
100-125
8-14
45
99
160
125-160
8-14
75
134
200
160-200
8-14
110
196
Screw terminals as
accessories
NZMB2-M125
265715
NZMB2-M160
265716
NZMB2-M200
265717
Screw terminals as
accessories
NZMC2-M125
271424
NZMC2-M160
271425
NZMC2-M200
271426
Screw terminals
asaccessories
NZMN2-M125
265723
NZMN2-M160
265724
NZMN2-M200
265725
S
S
S
S
S
S
Circuit-breakers, switch-disconnectors
Mechanical interlock for (door-coupling) rotary handles
1.3
NZM...M
Fixed mounting
with screw terminals
Part no.
Article no.
1
Plug-in units
Price
See price
list
Part no.
Article no.
Price
See price
list
Std.
pack
Notes
Order base
separately
B = box terminals
S = screw terminals
For further terminal types see
accessories
NZMB1-M40
265710
NZMB1-M50
265711
NZMB1-M63
265712
NZMB1-M80
265713
NZMB1-M100
265714
Terminals as
accessory
NZMB1-M40-SVE
112709
NZMB1-M50-SVE
112720
NZMB1-M63-SVE
112721
NZMB1-M80-SVE
112722
NZMB1-M100-SVE
112723
NZMB2-M125-SVE
113196
NZMB2-M160-SVE
113197
NZMC1-M40
271398
NZMC1-M50
271399
NZMC1-M63
271400
NZMC1-M80
271401
NZMC1-M100
271402
Terminals as
accessory
1 off
NZMB2-M200-SVE
113198
NZMC1-M40-SVE
112743
NZMC1-M50-SVE
112744
NZMC1-M63-SVE
112745
NZMC1-M80-SVE
112746
NZMC1-M100-SVE
112747
NZMC2-M125-SVE
113223
NZMC2-M160-SVE
113224
NZMN1-M40
265718
NZMN1-M50
265719
NZMN1-M63
265720
NZMN1-M80
265721
NZMN1-M100
265722
Terminals as
accessory
NZMC2-M200-SVE
113225
NZMN1-M40-SVE
112763
NZMN1-M50-SVE
112764
NZMN1-M63-SVE
112765
NZMN1-M80-SVE
112766
NZMN1-M100-SVE
112767
NZMN2-M125-SVE
113250
NZMN2-M160-SVE
113251
NZMN2-M200-SVE
113252
15
1.3
Circuit-breakers, switch-disconnectors
Auxiliary contacts, trip-indicating auxiliary contacts
NZM...M
Fixed mounting
with screw terminals
Switching
capacity
400/415 V
50/60 Hz
Rated current =
Rated
uninterrupted
current
Setting range
I cu
kA
In=Iu
A
Ir
A
Overload
releases
Short-circuit
releases
Non-delayed
Ii=In X ...
Rated operational
power
AC-3
50/60 Hz
Rated operational
current
400V
P
W
400V
Ie
A
Price
See price
list
Part no.
Article no.
I
High switching
capacity
Motor protection
NZM...1-M...: with phase failure sensitivity
Tripping class 10 A
100
High switching
capacity
16
150
40
32-40
8-14
18.5
36
50
40-50
8-14
22
41
30
50-63
8-14
30
55
80
63-80
8-14
37
68
100
80-100
8-12.5
45
81
20
16-20
350 A fixed
7.5
16
NZMH2-M20
281299
25
20-25
350 A fixed
11
21.7
NZMH2-M25
281300
32
25-32
10-14
15
29.3
NZMH2-M32
281301
40
32-40
8-14
18.5
36
NZMH2-M40
281302
50
40-50
8-14
22
41
63
50-63
8-14
30
55
80
63-80
8-14
37
68
100
80-100
8-14
45
81
125
100-125
8-14
45
99
160
125-160
8-14
75
134
200
160-200
8-14
110
196
NZMH2-M50
281303
NZMH2-M63
281304
NZMH2-M80
281305
NZMH2-M100
281306
NZMH2-M125
281307
NZMH2-M160
281308
NZMH2-M200
281309
Screw terminals as
accessories
S
S
S
S
S
S
Circuit-breakers, switch-disconnectors
Mechanical interlock for (door-coupling) rotary handles
1.3
1
Fixed mounting
with screw terminals
Part no.
Article no.
Plug-in units
Price
See price
list
Part no.
Article no.
Price
See price
list
Std.
pack
Notes
Order base
separately
B = box terminals
S = screw terminals
For further terminal types see
accessories
NZMH1-M40
115450
NZMH1-M40-SVE
115790
NZMH1-M50
115451
NZMH1-M50-SVE
115791
NZMH1-M63
115452
NZMH1-M63-SVE
115792
NZMH1-M80
115453
NZMH1-M80-SVE
115793
NZMH1-M100
115454
NZMH1-M100-SVE
115794
Terminals as
accessory
NZMH2-M20-SVE
113354
NZMH2-M25-SVE
113355
1 off
NZMH2-M32-SVE
113356
NZMH2-M40-SVE
113357
NZMH2-M50-SVE
113358
NZMH2-M63-SVE
113359
NZMH2-M80-SVE
113360
NZMH2-M100-SVE
113361
NZMH2-M125-SVE
113362
NZMH2-M160-SVE
113363
NZMH2-M200-SVE
113364
17
1.3
Circuit-breakers, switch-disconnectors
Auxiliary contacts, trip-indicating auxiliary contacts
NZM...M
1
Fixed mounting
with screw terminals
Switching
capacity
400/415 V
50/60 Hz
I cu
kA
Rated current =
Rated
uninterrupted
current
In=Iu
A
Setting range
Rated operational
power
AC-3
50/60 Hz
Rated operational
current
Short-circuit
releases
400V
400V
Non-delayed
Ii=In X ...
P
W
Ie
A
18.5
max.36
Part no.
Article no.
Price
See price
list
Short-circuit protection
Basic
switching
capacity
25
Comfort
switching
capacity
36
36
36
Normal
switching
capacity
18
50
Screw terminals as
accessories
50
8-14
22
max.41
63
8-14
30
max.55
80
8-14
37
max.68
100
8-12.5
45
max.99
125
8-14
45
max.99
NZMB2-S125
265736
160
8-14
75
max.134
NZMB2-S160
265737
200
8-12.5
110
max.196
NZMB2-S200
265738
40
8-14
18.5
max.36
Screw terminals as
accessories
50
8-14
22
max.41
63
8-14
30
max.55
80
8-14
37
max.68
100
8-12.5
45
max.99
125
8-14
45
max.99
NZMC2-S125
271427
160
8-14
75
max.134
NZMC2-S160
271428
200
8-12.5
110
max.196
NZMC2-S200
271429
250
8-14
132
max.231
NZMC3-S250
109676
320
8-14
160
max.279
NZMC3-S320
109677
400
6-10
200
max.349
NZMC3-S400
109678
500
6-10
250
max.437
NZMC3-S500
109679
40
8-14
18.5
max.36
Screw terminals as
accessories
50
8-14
22
max.41
63
8-14
30
max.55
80
8-14
37
max.68
100
8-12.5
45
max.99
1.3
Circuit-breakers, switch-disconnectors
Mechanical interlock for (door-coupling) rotary handles
1
Fixed mounting
with screw terminals
Part no.
Article no.
Plug-in/withdrawable units
Price
See price
list
Part no.
Article no.
Price
See price
list
Std.
pack
Notes
Order base
separately
B = box terminals
S = screw terminals
For further terminal types see
accessories
NZMB1-S40
265726
NZMB1-S40-SVE
112724
NZMB1-S50
265727
NZMB1-S50-SVE
112725
NZMB1-S63
265728
NZMB1-S63-SVE
112726
NZMB1-S80
265729
NZMB1-S80-SVE
112727
NZMB1-S100
265730
NZMB1-S100-SVE
112728
Terminals as
accessory
NZMB2-S125-SVE
113199
NZMB2-S160-SVE
113200
NZMB2-S200-SVE
113201
NZMC1-S40
271403
NZMC1-S40-SVE
112748
NZMC1-S50
271404
NZMC1-S50-SVE
112749
NZMC1-S63
271405
NZMC1-S63-SVE
112750
NZMC1-S80
271406
NZMC1-S80-SVE
112751
NZMC1-S100
271407
NZMC1-S100-SVE
112752
Terminals as
accessory
Tripping
class
10A
10
20
30
Maximum
permissible
tripping class
40
30
50
30
NZMC2-S160-SVE
113227
63
30
80
20
NZMC2-S200-SVE
113228
100
15
40
30
50
30
63
30
80
30
NZMC3-S400-AVE
113514
100
30
125
30
NZMC3-S500-AVE
113515
160
20
200
10
250
30
320
30
400
30
500
20
NZMC2-S125-SVE
113226
NZMC3-S250-AVE
113512
NZM...1-S...
NZM...2-S...
NZMC3-S320-AVE
113513
NZMC1-S40
271403
NZMC1-S50
271404
NZMN1-S40-SVE
112768
NZMN1-S50-SVE
112769
NZMN1-S63-SVE
112770
NZMC1-S63
271405
NZMC1-S80
271406
NZMN1-S80-SVE
112771
NZMC1-S100
271407
NZMN1-S100-SVE
112772
NZM...3-S...
19
Circuit-breakers, switch-disconnectors
1.3
1 NZM...-S
Fixed mounting
with screw terminals
Switching
capacity
400/415 V
50/60 Hz
I cu
kA
Setting range
Rated operational
power
AC-3
50/60 Hz
Rated operational
current
Short-circuit
releases
Non-delayed
Ii=In X ...
400V
400V
P
W
Ie
A
125
8-14
45
max.99
160
8-14
75
max.134
200
8-12.5
110
max.196
250
8-14
132
max.231
320
8-14
160
max.279
400
6-10
200
max.349
500
6-10
250
max.437
40
8-14
18.5
max.36
50
8-14
22
max.41
63
8-14
30
max.55
80
8-14
37
max.68
100
8-14
45
max.99
40
8-14
18.5
max.36
50
8-14
22
max.41
63
8-14
30
37
max.55
80
8-14
Rated current =
Rated
uninterrupted
current
In=Iu
A
Part no.
Article no.
Price
See price
list
Short-circuit protection
Motor protection in conjunction with overload relay
With short-circuit releases
Without overload releases Ir
Normal switching
capacity
High switching
capacity
50
100
150
max.68
45
100
8-14
max.99
45
125
8-14
max.99
75
160
8-14
max.134
110
200
8-12.5
max.196
132
20
250
8-14
320
8-14
160
max.279
400
6-10
200
max.349
500
6-10
250
max.437
max.231
NZMN2-S125
265739
NZMN2-S160
265740
NZMN2-S200
265741
NZMN3-S250
109680
NZMN3-S320
109681
NZMN3-S400
109682
NZMN3-S500
109683
S
S
S
S
S
S
S
Screw terminals as
accessories
NZMH2-S40
265742
NZMH2-S50
265743
NZMH2-S63
265744
NZMH2-S80
265745
NZMH2-S100
265746
NZMH2-S125
265747
NZMH2-S160
265748
NZMH2-S200
265749
NZMH3-S250
109684
NZMH3-S320
109685
NZMH3-S400
109686
NZMH3-S500
109687
S
S
S
S
S
S
S
S
S
S
S
S
1.3
Circuit-breakers, switch-disconnectors
Mechanical interlock for (door-coupling) rotary handles
1
Fixed mounting
with screw terminals
Part no.
Article no.
Plug-in/withdrawable units
Part no.
Article no.
Price
See price
list
Price
See price
list
Std.
pack
Notes
Order base
separately
Terminals as
accessory
NZMH1-S40
284436
NZMH1-S50
284437
NZMH1-S63
284438
NZMH1-S80
284439
NZMH1-S100
284440
Terminals as
accessory
NZMN2-S125-SVE
113253
NZMN2-S160-SVE
113254
NZMN2-S200-SVE
113255
NZMN3-S250-AVE
113523
NZMN3-S320-AVE
113524
NZMN3-S400-AVE
113525
NZMN3-S500-AVE
113526
B
B
B
B
B
NZMH1-S40-SVE
112805
NZMH1-S50-SVE
112806
NZMH1-S63-SVE
112807
NZMH1-S80-SVE
112808
NZMH1-S100-SVE
112809
NZMH2-S40-SVE
113340
NZMH2-S50-SVE
113341
NZMH2-S63-SVE
113342
NZMH2-S80-SVE
113343
NZMH2-S100-SVE
113344
NZMH2-S125-SVE
113345
NZMH2-S160-SVE
113346
NZMH2-S200-SVE
113347
NZMH3-S250-AVE
113566
NZMH3-S320-AVE
113567
NZMH3-S400-AVE
113568
NZMH3-S500-AVE
113569
1 off
B = box terminals
S = screw terminals
For further terminal types see
accessories
IEC/EN 60947-4-1, IEC/EN 60947-2
The circuit-breakers fulfill all
requirements for utilization
category AC-3.
Tripping
class
10A
10
20
30
1 off
NZM...1-S...
NZM...2-S...
NZM...3-S...
In in A
Maximum
permissible
tripping class
40
30
50
30
63
30
80
20
100
15
40
30
50
30
63
30
80
30
100
30
125
30
160
20
200
10
250
30
320
30
400
30
500
20
21
1.3
Circuit-breakers, switch-disconnectors
Circuit-breakers, electronic releases, 3 pole
1 NZM...AE
Switching
capacity
400/415 V
50/60 Hz
I cu
kA
Rated current =
Rated
uninterrupted
current
In = I u
A
Fixed mounting
with screw terminals
Part no.
Article no.
Setting range
Overload releases
Ir
A
Short-circuit releases
Non-delayed
Ii = I n x
Price
See price
list
I
System and cable protection
Normal switching
capacity
50
630
315-630
2-8
NZMN3-AE630
259115
50
630
315-630
2-12
800
400-800
2-12
1000
500-1000
2-12
1250
630-1250
2-12
1600
800-1600
2-12
NZMN4-AE630
265758
NZMN4-AE800
265759
NZMN4-AE1000
265760
NZMN4-AE1250
265761
NZMN4-AE1600
265762
150
630
315-630
2-8
NZMH3-AE630
259118
85
630
315-630
2-12
800
400-800
2-12
1000
500-1000
2-12
1250
630-1250
2-12
1600
800-1600
2-12
250
125-250
2-11
400
200-400
2-11
630
315-630
2-8
250
125-250
2-11
400
200-400
2-11
630
315-630
2-8
NZMH4-AE630
265763
NZMH4-AE800
265764
NZMH4-AE1000
265765
NZMH4-AE1250
265766
NZMH4-AE1600
265767
NZMN3-AE250-T
110888
NZMN3-AE400-T
110889
NZMN3-AE630-T
110890
NZMH3-AE250-T
110894
NZMH3-AE400-T
110895
NZMH3-AE630-T
110896
S
S
S
S
S
50
150
22
S
S
S
S
S
S
S
S
S
S
S
Circuit-breakers, switch-disconnectors
Fixed mounting
with box terminals
Part no.
Article no.
1.3
1
Withdrawable units
Price
See price
list
Part no.
Article no.
Price
See price
list
Std.
pack
Notes
Order base
separately
B = box terminals
S = screw terminals
NZMN3-AE630-BT
111656
NZMN3-AE630-AVE
110842
1 off
Terminals as accessory
Withdrawable units as
accessories
Terminals as accessory
NZMH3-AE630-AVE
110851
1 off
Withdrawable units as
accessories
Terminals as accessory
NZMN3-AE250-T-AVE
113527
NZMN3-AE400-T-AVE
113528
NZMN3-AE630-T-AVE
113093
NZMH3-AE250-T-AVE
113570
NZMH3-AE400-T-AVE
113571
NZMH3-AE630-T-AVE
113572
1 off
23
Circuit-breakers, switch-disconnectors
1.3
1 NZM...VE
Switching capacity
400/415 V 50/60 Hz
Rated current =
Rated uninterrupted
current
Setting range
I cu
In=Iu
Overload
releases
Ir
kA
Short-circuit releases
Non-delayed
Delayed
Ii=In X ...
Isd=Ir X ...
Fixed mounting
with screw terminals
Part no.
Article no.
Price
See price
list
I
Systems protection, cable protection, selectivity, generator protection
Normal switching capacity
50
150
85
50
150
24
100
50-100
1200 A fixed
2-10
160
80-160
1920 A fixed
2-10
250
125-250
3000 A fixed
2-10
250
125-250
2-11
2-10
400
200-400
2-11
2-10
630
315-630
2-8
1.5-7
630
315-630
2-12
1.5-7
800
400-800
2-12
2-10
1000
500-1000
2-12
2-10
1250
630-1250
2-12
2-10
1600
800-1600
2-12
2-10
100
50-100
1200 A fixed
2-10
160
80-160
1920 A fixed
2-10
250
125-250
3000 A fixed
2-10
250
125-250
2-11
2-10
400
200-400
2-11
2-10
630
315-630
2-8
1.5-7
630
315-630
2-12
1.5-7
800
400-800
2-12
2-10
1000
500-1000
2-12
2-10
1250
630-1250
2-12
2-10
1600
800-1600
2-12
2-10
250
125-250
2-11
2-10
400
200-400
2-11
2-10
630
315-630
2-8
1.5-7
250
125-250
2-11
2-10
400
200-400
2-11
2-10
630
315-630
2-8
1.5-7
NZMN2-VE100
259122
NZMN2-VE160
259123
NZMN2-VE250
259124
NZMN3-VE250
259131
NZMN3-VE400
259132
NZMN3-VE630
259133
NZMN4-VE630
265768
NZMN4-VE800
265769
NZMN4-VE1000
265770
NZMN4-VE1250
265771
NZMN4-VE1600
265772
NZMH2-VE100
259125
NZMH2-VE160
259126
NZMH2-VE250
259127
NZMH3-VE250
259134
NZMH3-VE400
259135
NZMH3-VE630
259136
NZMH4-VE630
265773
NZMH4-VE800
265774
NZMH4-VE1000
265775
NZMH4-VE1250
265776
NZMH4-VE1600
265777
NZMN3-VE250-T
110891
NZMN3-VE400-T
110892
NZMN3-VE630-T
110893
NZMH3-VE250-T
110897
NZMH3-VE400-T
110898
NZMH3-VE630-T
110899
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Circuit-breakers, switch-disconnectors
Fixed mounting
with screw terminals
Part no.
Article no.
1.3
1
Withdrawable units
Price
See price
list
Part no.
Article no.
Price
See price
list
Std.
pack
Notes
Order base
separately
Terminals as accessory
NZMN3-VE400-BT
111659
NZMN3-VE630-BT
111730
Terminals as accessory
1,467.37
43
1,914.22
43
Terminals as accessory
NZMH3-VE400-BT
111731
NZMH3-VE630-BT
111732
1,668.52
43
2,079.92
43
NZMN2-VE100-SVE
113247
NZMN2-VE160-SVE
113248
NZMN2-VE250-SVE
113249
NZMN3-VE250-AVE
110843
NZMN3-VE400-AVE
110844
NZMN3-VE630-AVE
110845
1 off
NZMH2-VE100-SVE
113337
NZMH2-VE160-SVE
113338
NZMH2-VE250-SVE
113339
NZMH3-VE250-AVE
110852
NZMH3-VE400-AVE
110853
NZMH3-VE630-AVE
110854
1 off
Terminals as accessory
Withdrawable units as
accessories
Terminals as accessory
NZMN3-VE250-T-AVE
113529
NZMN3-VE400-T-AVE
113530
B = box terminals
S = screw terminals
For further terminal types see
accessories
IEC/EN 60947-2
R.m.s. value measurement and
thermal memory
Adjustable delay setting t r
2 20 s at 6 x Ir and infinite
(without overload release)
Adjustable delay t sd
Steps: 0, 20, 60, 100, 200, 300, 500, 750,
1000 ms
i2t constant function
NZM2 fixed OFF
NZM3, NZM4 switchable
1 off
NZMN3-VE630-T-AVE
113531
NZMH3-VE250-T-AVE
113573
NZMH3-VE400-T-AVE
113574
NZMH3-VE630-T-AVE
113575
25
Circuit-breakers, switch-disconnectors
1.3
1 NZM...M
HPL17026EN
Fixed mounting
with screw terminals
Switching
capacity
400/415 V
50/60 Hz
Rated current =
Rated
uninterrupted
current
Setting range
I cu
kA
In=Iu
A
Ir
A
Overload
releases
Short-circuit
releases
Non-delayed
Ii=In X ...
Rated operational
power
AC-3
50/60 Hz
Rated operational
current
AC-3
50/60 Hz
400V
P
kW
690V
P
kW
400V
Ie
A
690V
Ie
A
45
75
81
78
Part no.
Article no.
Price
See price
list
I
Motor protection
With phase-failure sensitivity
50
Normal switching
capacity
High switching
capacity
150
85
26
90
45-90
2-14
140
70-140
2-14
75
132
134
134
220
110-220
2-14
110
200
196
202
220
110-220
2-14
110
200
196
202
350
175-350
2-14
200
315
349
316
450
225-450
2-12
250
450
437
446
550
275-550
2-14
315
560
544
550
875
438-875
2-14
500
600
820
588
1400
700-1400
2-14
630
600
1066
588
90
45-90
2-14
45
45
81
78
140
70-140
2-14
75
132
134
134
220
110-220
2-14
110
200
196
202
220
110-220
2-14
110
200
196
202
350
175-350
2-14
200
315
349
316
450
225-450
2-12
250
450
437
446
550
275-550
2-14
315
560
544
550
875
438-875
2-14
500
600
820
588
1400
700-1400
2-14
630
600
1066
588
S
NZMN2-ME90
265778
NZMN2-ME140
265779
NZMN2-ME220
NZMN3-ME220
265780
265781
NZMN3-ME350
265782
NZMN3-ME450
284468
S
S
S
S
S
NZMN4-ME550
265783
NZMN4-ME875
265784
NZMN4-ME1400
265785
NZMH2-ME90
265786
NZMH2-ME140
265787
NZMH2-ME220
265788
NZMH3-ME220
265789
NZMH3-ME350
265790
NZMH3-ME450
284469
NZMH4-ME550
265791
NZMH4-ME875
265792
NZMH4-ME1400
265793
S
S
S
S
S
S
S
S
S
Circuit-breakers, switch-disconnectors
1.3
1
Plug-in units
Part no.
Article no.
Price
See price
list
Std.
pack
Notes
Order base
separately
NZMN2-ME90-SVE
113256
NZMN2-ME140-SVE
113257
NZMN2-ME220-SVE
113258
NZMN3-ME220-AVE
110846
NZMN3-ME350-AVE
110847
NZMN3-ME450-AVE
110848
Withdrawable units as
accessories
1 off
NZMH2-ME90-SVE
113348
NZMH2-ME140-SVE
113349
NZMH2-ME220-SVE
113350
NZMH3-ME220-AVE
110855
NZMH3-ME350-AVE
110856
NZMH3-ME450-AVE
110857
Withdrawable units as
accessories
1 off
B = box terminals
S = screw terminals
For further terminal types see accessories
IEC/EN 60947-4-1, IEC/EN 60947-2
The circuit-breakers fulfill all requirements for utilization category AC-3
R.m.s. value measurement and "thermal memory"
Adjustable delay setting t,
220 s at 6 x I and infinite (without overload release)
27
Circuit-breakers, switch-disconnectors
1.3
NZM...A
Fixed mounting
with screw terminals
Part no.
Article no.
1
Switching
capacity
400/415 V
50/60 Hz
Rated current =
Rated uninterrupted current
I cu
In = I u
kA
Phase conductors
Neutral
conductor
I r x % of phase
conductor
%
Setting range
Overload releases
Phase
conductors
Ir
Ir
A
Short-circuit
releases
Non-delayed
Ii = I n x
Price
See price
list
I
System and cable protection
25
Comfort switching
capacity
28
36
20
100
15-20
1520
350 A fixed
25
100
20-25
2025
350 A fixed
32
100
25-32
2532
350 A fixed
40
100
32-40
3240
8-10
50
100
40-50
4050
6-10
63
100
50-63
5063
6-10
80
100
63-80
6380
6-10
100
100
80-100
80100
6-10
125
100
100-125
100125
6-10
160
100
125-160
125160
1280 A fixed
160
100
125-160
125160
6-10
160
60
125-160
80100
6-10
200
100
160-200
160200
6-10
200
60
160-200
100125
6-10
250
100
200-250
200250
6-10
250
60
200-250
125160
6-10
300
100
240-300
240300
6-10
300
60
240-300
160200
6-10
20
100
15-20
1520
350 A fixed
25
100
20-25
2025
350 A fixed
32
100
25-32
2532
350 A fixed
40
100
32-40
3240
8-10
50
100
40-50
4050
6-10
63
100
50-63
5063
6-10
80
100
63-80
6380
6-10
100
100
80-100
80100
6-10
125
100
100-125
100125
6-10
160
100
125-160
125160
1280 A fixed
Screw terminals as
accessories
NZMB2-4-A160
265849
NZMB2-4-A160/100
265850
NZMB2-4-A200
265852
NZMB2-4-A200/125
265853
NZMB2-4-A250
265855
NZMB2-4-A250/160
265856
NZMB2-4-A300
107582
NZMB2-4-A300/200
107583
Screw terminals as
accessories
S
S
S
S
S
S
S
S
Circuit-breakers, switch-disconnectors
Mechanical interlock for (door-coupling) rotary handles
Fixed mounting
with box terminals
Part no.
Article no.
1.3
Plug-in units
Price
See price
list
Part no.
Article no.
Price
See price
list
Std. pack
Notes
B = box terminals
S = screw terminals
NZMB1-4-A20
281237
NZMB1-4-A25
281239
NZMB1-4-A32
281241
NZMB1-4-A40
265799
NZMB1-4-A50
265801
NZMB1-4-A63
265803
NZMB1-4-A80
265805
NZMB1-4-A100
265807
NZMB1-4-A125
265809
NZMB1-4-A160
281243
1 off
NZMB2-4-A160-SVE
113209
NZMB2-4-A160/100-SVE
113210
NZMB2-4-A200-SVE
113212
NZMB2-4-A200/125-SVE
113213
NZMB2-4-A250-SVE
113215
NZMB2-4-A250/160-SVE
113216
Terminals as accessory
NZMC1-4-A20
283300
NZMC1-4-A25
283302
NZMC1-4-A32
283304
NZMC1-4-A40
271408
NZMC1-4-A50
271410
NZMC1-4-A63
271412
NZMC1-4-A80
271414
NZMC1-4-A100
271416
NZMC1-4-A125
271418
NZMC1-4-A160
283306
1 off
29
Circuit-breakers, switch-disconnectors
1.3
1 NZM...-4-A
Switching
capacity
400/415 V
50/60 Hz
Rated current =
Rated uninterrupted current
Fixed mounting
with screw terminals
Part no.
Article no.
Setting range
Overload releases
I cu
Phase
conductors
In = I u
kA
Neutral
conductor
I r x % of phase
conductor
%
Ir
Phase
conductors
Ir
Short-circuit
releases
Non-delayed
Price
See price
list
Ii = I n x
I
System and cable protection
Comfort switching
capacity
36
125
100
100-125
100...125
6-10
160
100
125-160
125...160
6-10
160
60
125-160
80...100
6-10
200
100
160-200
160...200
6-10
200
60
160-200
100...125
6-10
250
100
200-250
200...250
6-10
250
60
200-250
125...160
6-10
300
100
240-300
240...300
6-10
300
60
240-300
160...200
6-10
320
100
250-320
250...320
6-10
320
60
250-320
160...200
6-10
400
100
320-400
320...400
6-10
400
60
320-400
200...250
6-10
500
100
400-500
400...500
6-10
500
Normal switching
capacity
30
50
20
25
32
40
50
63
80
100
125
160
60
100
100
100
100
100
100
100
100
100
100
400-500
15-20
20-25
25-32
32-40
40-50
50-63
63-80
80-100
100-125
125-160
250...320
15...20
20...25
25...32
32...40
40...50
50...63
63...80
80...100
100...125
125...160
6-10
350 A fixed
350 A fixed
350 A fixed
8-10
6-10
6-10
6-10
6-10
6-10
1280 A fixed
NZMC2-4-A125
271430
NZMC2-4-A160
271432
NZMC2-4-A160/100
271433
NZMC2-4-A200
271435
NZMC2-4-A200/125
271436
NZMC2-4-A250
271438
NZMC2-4-A250/160
271439
NZMC2-4-A300
107584
NZMC2-4-A300/200
107585
NZMC3-4-A320
109688
NZMC3-4-A320/200
109689
NZMC3-4-A400
109690
NZMC3-4-A400/250
109691
NZMC3-4-A500
109692
NZMC3-4-A500/320
109693
Screw terminals as
accessories
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Circuit-breakers, switch-disconnectors
1.3
1
Fixed mounting
with screw terminals
Part no.
Article no.
Plug-in units
Price
See price
list
Part no.
Article no.
Price
See price
list
Std.
pack
Notes
Order base
separately
Terminals as accessory
NZMC2-4-A125-SVE
113231
NZMC2-4-A160-SVE
113233
NZMC2-4-A160/100-SVE
113234
NZMC2-4-A200-SVE
113236
NZMC2-4-A200/125-SVE
113237
NZMC2-4-A250-SVE
113239
NZMC2-4-A250/160-SVE
113240
NZMC3-4-A320-AVE
113516
NZMC3-4-A320/200-AVE
113517
NZMC3-4-A400-AVE
113518
NZMC3-4-A400/250-AVE
113519
NZMC3-4-A500-AVE
113520
NZMC3-4-A500/320-AVE
113521
1 off
1 off
NZMN1-4-A20
281245
NZMN1-4-A25
281247
NZMN1-4-A32
281249
NZMN1-4-A40
265811
NZMN1-4-A50
265813
NZMN1-4-A63
265815
NZMN1-4-A80
265817
NZMN1-4-A100
265819
NZMN1-4-A125
265821
NZMN1-4-A160
281251
B = box terminals
S = screw terminals
For further terminal types see
accessories
IEC/EN 60947-2
Set value for neutral
conductor is same as set
value Ir for main pole.
31
Circuit-breakers, switch-disconnectors
1.3
1 NZM...-4-A
Fixed mounting
with screw terminals
Switching
capacity
400/415 V
50/60 Hz
Rated current =
Rated uninterrupted current
Phase
conductors
Neutral
conductor
I cu
In=Iu
kA
I r x % of phase
conductor
%
Setting range
Overload releases
Phase
conductors
Short-circuit
releases
Non-delayed
Ir
Ir
Ii=In X ...
Part no.
Article no.
Price
See price
list
I
System and cable protection
Normal switching
capacity
High switching
capacity
32
50
100
160
100
125-160
125...160
6-10
160
60
125-160
80...100
6-10
200
100
160-200
160...200
6-10
200
60
160-200
100...125
6-10
250
100
200-250
200...250
6-10
250
60
200-250
125...160
6-10
300
100
240-300
240...300
6-10
300
60
240-300
160...200
6-10
320
100
250-320
250...320
6-10
320
60
250-320
160...200
6-10
400
100
320-400
320...400
6-10
400
60
320-400
200...250
6-10
500
100
400-500
400...500
6-10
500
60
400-500
250...320
6-10
20
25
32
40
50
63
80
100
125
160
100
100
100
100
100
100
100
100
100
100
15-20
20-25
25-32
32-40
40-50
50-63
63-80
80-100
100-125
125-160
15...20
20...25
25...32
32...40
40...50
50...63
63...80
80...100
100...125
125...160
350 A fixed
350 A fixed
350 A fixed
8-10
6-10
6-10
6-10
6-10
6-10
1280 A fixed
NZMN2-4-A160
265860
NZMN2-4-A160/100
265861
NZMN2-4-A200
265863
NZMN2-4-A200/125
265864
NZMN2-4-A250
265866
NZMN2-4-A250/160
265867
NZMN2-4-A300
107586
NZMN2-4-A300/200
107587
NZMN3-4-A320
109694
NZMN3-4-A320/200
109695
NZMN3-4-A400
109696
NZMN3-4-A400/250
109697
NZMN3-4-A500
109698
NZMN3-4-A500/320
109699
Screw terminals as
accessories
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Circuit-breakers, switch-disconnectors
NZM...-4-A
Fixed mounting
with box terminals
Part no.
Article no.
1.3
1
Plug-in units
Price
See price
list
Part no.
Article no.
Price
See price
list
Std. pack
Notes
B = box terminals
S = screw terminals
For further terminal types see
accessories
NZMN2-4-A160-SVE
113266
NZMN2-4-A160/100-SVE
113267
NZMN2-4-A200-SVE
113269
NZMN2-4-A200/125-SVE
113270
NZMN2-4-A250-SVE
113272
NZMN2-4-A250/160-SVE
113273
NZMN3-4-A320-AVE
113532
NZMN3-4-A320/200-AVE
113533
NZMN3-4-A400-AVE
113534
NZMN3-4-A400/250-AVE
113535
NZMN3-4-A500-AVE
113536
NZMN3-4-A500/320-AVE
113537
1 off
1 off
Terminals as accessory
NZMH1-4-A20
284416
NZMH1-4-A25
284418
NZMH1-4-A32
284420
NZMH1-4-A40
284422
NZMH1-4-A50
284424
NZMH1-4-A63
284426
NZMH1-4-A80
284428
NZMH1-4-A100
284430
NZMH1-4-A125
284432
NZMH1-4-A160
284434
IEC/EN 60947-2
Set value for neutral
conductor is same as set
value Ir for main pole.
33
Circuit-breakers, switch-disconnectors
1.3
1 NZM...-4-A
Switching
capacity
400/415 V
50/60 Hz
I cu
kA
Rated current =
Rated uninterrupted current
Phase
conductors
In = I u
A
Neutral
conductor
I r x % of phase
conductor
%
Fixed mounting
with screw terminals
Part no.
Article no.
Setting range
Overload releases
Phase
conductors
Ir
Ir
A
Short-circuit
releases
Non-delayed
Ii = I n x
Price
See price
list
I
System and cable protection
High switching
capacity
150
150
34
20
100
15-20
1520
350 A fixed
25
100
20-25
2025
350 A fixed
32
100
25-32
2532
350 A fixed
40
100
32-40
3240
6-10
50
100
40-50
4050
6-10
63
100
50-63
5063
6-10
80
100
63-80
6380
6-10
100
100
80-100
80100
6-10
125
100
100-125
100125
6-10
160
100
125-160
125160
6-10
160
60
125-160
80100
6-10
200
100
160-200
160200
6-10
200
60
160-200
100125
250
100
200-250
200250
6-10
250
60
200-250
125160
6-10
300
100
240-300
240300
6-10
300
60
240-300
160200
6-10
320
100
250-320
250320
6-10
320
60
250-320
160200
6-10
400
100
320-400
320400
6-10
400
60
320-400
200250
6-10
500
100
400-500
400500
6-10
500
60
400-500
250320
6-10
NZMH2-4-A20
281287
NZMH2-4-A25
281289
NZMH2-4-A32
281291
NZMH2-4-A40
265823
NZMH2-4-A50
265825
NZMH2-4-A63
265827
NZMH2-4-A80
265829
NZMH2-4-A100
265831
NZMH2-4-A125
265833
NZMH2-4-A160
265871
NZMH2-4-A160/100
265872
NZMH2-4-A200
265874
NZMH2-4-A200/125
265875
NZMH2-4-A250
265877
NZMH2-4-A250/160
265878
NZMH2-4-A300
107588
NZMH2-4-A300/200
107589
NZMH3-4-A320
109700
NZMH3-4-A320/200
109701
NZMH3-4-A400
109702
NZMH3-4-A400/250
109703
NZMH3-4-A500
109704
NZMH3-4-A500/320
109705
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Circuit-breakers, switch-disconnectors
Fixed mounting
with box terminals
Part no.
Article no.
1.3
1
Plug-in units
Price
See price
list
Part no.
Article no.
Price
See price
list
Std. pack
Notes
B = box terminals
S = screw terminals
Terminals as accessory
NZMH2-4-A20-SVE
113396
NZMH2-4-A25-SVE
113398
NZMH2-4-A32-SVE
113400
NZMH2-4-A40-SVE
113367
NZMH2-4-A50-SVE
113369
NZMH2-4-A63-SVE
113371
NZMH2-4-A80-SVE
113373
NZMH2-4-A100-SVE
113375
NZMH2-4-A125-SVE
113377
NZMH2-4-A160-SVE
113379
NZMH2-4-A160/100-SVE
113380
NZMH2-4-A200-SVE
113382
NZMH2-4-A200/125-SVE
113383
NZMH2-4-A250-SVE
113385
NZMH2-4-A250/160-SVE
113386
1 off
NZMH3-4-A320-AVE
113578
NZMH3-4-A320/200-AVE
113579
NZMH3-4-A400-AVE
113580
NZMH3-4-A400/250-AVE
113581
NZMH3-4-A500-AVE
113582
NZMH3-4-A500/320-AVE
113583
1 off
35
Circuit-breakers, switch-disconnectors
1.3
Switching
capacity
400/415 V
50/60 Hz
Rated current =
Rated uninterrupted current
Phase
Neutral
conductors
conductor
Setting range
Overload releases
Phase
conductors
Short-circuit releases
NonDelayed
delayed
I cu
In = I u
Ir
Ir
Ii = I n x
kA
I r x % of phase
conductor
%
High switching
capacity
Earth fault
protection
50
630
100
315-630
315630
2-8
630
60
315-630
200400
2-8
800
100
400-800
400800
2-12
800
60
400-800
250500
2-12
1000
100
500-1000
5001000
2-12
1000
60
500-1000
315630
2-12
1250
100
630-1250
6301250
2-12
1250
60
630-1250
400800
2-12
1600
100
800-1600
8001600
2-12
1600
60
800-1600
5001000
2-12
150
630
100
315-630
315630
2-8
150
630
60
315-630
200400
2-8
85
800
100
400-800
400800
2-12
800
60
400-800
250500
2-12
1000
100
500-1000
5001000
2-12
1000
60
500-1000
315630
2-12
1250
100
630-1250
6301250
2-12
1250
60
630-1250
400800
2-12
1600
100
800-1600
8001600
2-12
1600
60
800-1600
5001000
2-12
400
100
200-400
200400
2-11
400
60
200-400
125250
2-11
630
100
315-630
315630
2-8
630
60
315-630
200400
2-8
400
100
200-400
200400
2-11
400
60
200-400
125250
2-11
630
100
315-630
315630
2-8
50
150
630
36
60
315-630
200400
2-8
Price
See price
list
I sd = I r x
I
Normal switching
capacity
Fixed mounting
with screw terminals
Part no.
Article no.
NZMN3-4-AE630
265894
NZMN3-4-AE630/400
265895
NZMN4-4-AE800
265909
NZMN4-4-AE800/500
265910
NZMN4-4-AE1000
265912
NZMN4-4-AE1000/630
265913
NZMN4-4-AE1250
265915
NZMN4-4-AE1250/800
265916
NZMN4-4-AE1600
265918
NZMN4-4-AE1600/1000
265919
NZMH3-4-AE630
265900
NZMH3-4-AE630/400
265901
NZMH4-4-AE800
265921
NZMH4-4-AE800/500
265922
NZMH4-4-AE1000
265924
NZMH4-4-AE1000/630
265925
NZMH4-4-AE1250
265927
NZMH4-4-AE1250/800
265928
NZMH4-4-AE1600
265930
NZMH4-4-AE1600/1000
265931
NZMN3-4-AE400-T
110902
NZMN3-4-AE400/250-T
110903
NZMN3-4-AE630-T
110904
NZMN3-4-AE630/400-T
110905
NZMH3-4-AE400-T
110906
NZMH3-4-AE400/250-T
110907
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
NZMH3-4-AE630-T
110908
NZMH3-4-AE630/400-T
110909
Circuit-breakers, switch-disconnectors
1.3
1
Fixed mounting
with screw terminals
Part no.
Article no.
Plug-in units
Price
See price
list
Part no.
Article no.
Price
See price
list
Std.
pack
Notes
Order base
separately
NZMN3-4-AE630-BT
111658
Terminals as
accessory
NZMN3-4-AE630-AVE
110875
NZMN3-4-AE630/400-AVE
113544
1 off
B = box terminals
S = screw terminals
For further terminal types see
accessories
IEC/EN 60947-2
R.m.s. value measurement
and thermal memory
Withdrawable units as
accessories
NZMH3-4-AE630-AVE
110879
NZMH3-4-AE630/400-AVE
113590
Withdrawable units as
accessories
Terminals as
accessory
NZMN3-4-AE400-T-AVE
113538
NZMN3-4-AE400/250-T-AVE
113539
NZMN3-4-AE630-T-AVE
113540
NZMN3-4-AE630/400-T-AVE
113541
1 off
1 off
NZMH3-4-AE400-T-AVE
113584
NZMH3-4-AE400/250-T-AVE
113585
NZMH3-4-AE630-T-AVE
113586
NZMH3-4-AE630/400-T-AVE
113587
37
Circuit-breakers, switch-disconnectors
1.3
1 NZM...-4-VE
Switching
capacity
400/415 V
50/60 Hz
Rated current =
Rated uninterrupted current
Phase
conductors
Neutral
conductor
I cu
In=Iu
kA
I r x % of phase
conductor
%
Setting range
Overload releases
Phase
conductors
Ir
Ir
Short-circuit
releases
Nondelayed
Delayed
Ii=In X ...
Isd= Ir x...
38
50
100
100
50-100
50...100
2-10
160
100
80-160
80...160
2-10
160
60
80-160
50...100
2-10
250
100
125-250
125...250
2-10
250
60
125-250
80...160
2-10
400
100
200-400
200...400
2-10
400
60
200-400
125...250
2-10
630
100
315-630
315...630
1.5-7
630
60
315-630
200...400
1.5-7
800
100
400-800
400...800
2-10
800
60
400-800
250...500
2-10
1000
100
500-1000
500...1000
2-10
1000
60
500-1000
315...630
2-10
1250
100
630-1250
630...1250
2-10
1250
60
630-1250
400...800
2-10
1600
100
800-1600
800...1600
2-10
1600
60
800-1600
500...1000
2-10
Price
See price
list
I
Normal switching
capacity
Fixed mounting
with screw terminals
Part no.
Article no.
NZMN2-4-VE100
265933
NZMN2-4-VE160
265935
NZMN2-4-VE160/100
265936
NZMN2-4-VE250
265938
NZMN2-4-VE250/160
265939
NZMN3-4-VE400
265957
NZMN3-4-VE400/250
265958
NZMN3-4-VE630
265960
NZMN3-4-VE630/400
265961
NZMN4-4-VE800
265975
NZMN4-4-VE800/500
265976
NZMN4-4-VE1000
265978
NZMN4-4-VE1000/630
265979
NZMN4-4-VE1250
265981
NZMN4-4-VE1250/800
265982
NZMN4-4-VE1600
265984
NZMN4-4-VE1600/1000
265985
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Circuit-breakers, switch-disconnectors
1.3
HPL17039EN
Fixed mounting
with screw terminals
Part no.
Article no.
Plug-in units
Price
See price
list
Part no.
Article no.
Price
See price
list
Std.
pack
Notes
B = box terminals
S = screw terminals
For further terminal types see
accessories
Terminals as
accessory
NZMN2-4-VE100-SVE
113275
NZMN2-4-VE160-SVE
113277
NZMN2-4-VE160/100-SVE
113278
NZMN2-4-VE250-SVE
113280
NZMN2-4-VE250/160-SVE
113281
NZMN3-4-VE400-AVE
110876
NZMN3-4-VE400/250-AVE
113546
NZMN3-4-VE630-AVE
110877
NZMN3-4-VE630/400-AVE
113548
Withdrawable units as
accessories
1 off
IEC/EN 60947-2
Set value for neutral
conductor is same as set
value Ir for main pole.
R.m.s. value measurement
and thermal memory
Adjustable delay setting
t
r
2 20 s atr 6and
x I infinite
(without overload release)
NZM...3-4-VE400(630):
2 14 s at 6 xr and
I
infinite (without overload
release)
Adjustable delay
sd t
Steps: 0, 20, 60, 100, 200,
300, 500, 750, 1000 ms
i2t constant function
NZM2 fixed OFF
NZM3, NZM4 switchable
39
Circuit-breakers, switch-disconnectors
1.3
1
NZM...-4-VE
Switching
capacity
400/415 V
50/60 Hz
Rated current =
Rated uninterrupted current
Phase
conductors
Neutral
conductor
Icu
In=Iu
kA
I r x % of phase
conductor
%
Setting range
Overload releases
Phase
conductors
Ir
Ir
Short-circuit
releases
NonDelayed
delayed
Ii=In X ...
150
85
Earth fault
protection
50
150
40
100
100
50-100
50...100
160
100
80-160
80...160
160
60
80-160
50...100
250
100
125-250
125...250
250
60
125-250
80...160
400
100
200-400
400
60
630
I
2-10
200...400
1200 A
fixed
1920 A
fixed
1920 A
fixed
3000 A
fixed
3000 A
fixed
2-11
200-400
125...250
2-11
2-10
100
315-630
315...630
2-8
1.5-7
630
60
315-630
200...400
2-8
1.5-7
800
100
400-800
400...800
2-12
2-10
800
60
400-800
250...500
2-12
2-10
1000
100
500-1000
500...1000
2-12
2-10
1000
60
500-1000
315...630
2-12
2-10
1250
100
630-1250
630...1250
2-12
2-10
1250
60
630-1250
400...800
2-12
2-10
1600
100
800-1600
800...1600
2-12
2-10
1600
60
800-1600
500...1000
2-12
2-10
400
100
200-400
200...400
2-11
2-10
630
100
315-630
315...630
2-8
1.5-7
400
100
200-400
200...400
2-11
2-10
630
100
315-630
315...630
2-8
1.5-7
Price
See price
list
Isd= Ir x...
I
High switching
capacity
Part no.
Article no.
2-10
2-10
2-10
2-10
2-10
NZMH2-4-VE100
265941
NZMH2-4-VE160
265943
NZMH2-4-VE160/100
265944
NZMH2-4-VE250
265946
NZMH2-4-VE250/160
265947
NZMH3-4-VE400
265963
NZMH3-4-VE400/250
265964
NZMH3-4-VE630
265966
NZMH3-4-VE630/400
265967
NZMH4-4-VE800
265987
NZMH4-4-VE800/500
265988
NZMH4-4-VE1000
265990
NZMH4-4-VE1000/630
265991
NZMH4-4-VE1250
265993
NZMH4-4-VE1250/800
265994
NZMH4-4-VE1600
265996
NZMH4-4-VE1600/1000
265997
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Circuit-breakers, switch-disconnectors
1.3
1
Fixed mounting
with screw terminals
Part no.
Article no.
Plug-in units
Price
See price
list
Part no.
Article no.
Price
See price
list
Std.
pack
Notes
Order base
separately
Terminals as
accessory
NZMH2-4-VE100-SVE
113388
NZMH2-4-VE160-SVE
113390
NZMH2-4-VE160/100-SVE
113391
NZMH2-4-VE250-SVE
113393
NZMH2-4-VE250/160-SVE
113394
NZMH3-4-VE400-AVE
110880
NZMH3-4-VE400/250-AVE
113592
NZMH3-4-VE630-AVE
110881
NZMH3-4-VE630/400-AVE
113594
Withdrawable units as
accessories
1 off
NZMN3-4-VE400-T-AVE
119902
NZMN3-4-VE630-T-AVE
119903
NZMH3-4-VE400-T-AVE
119900
NZMH3-4-VE630-T-AVE
119901
1 off
B = box terminals
S = screw terminals
For further terminal types see
accessories
IEC/EN 60947-2
Set value for neutral
conductor is same as set
value Ir for main pole.
R.m.s. value measurement
and thermal memory
Adjustable delay setting t r
2 20 s at 6 x Ir and infinite
(without overload release)
NZM...3-4-VE400(630):
2 14 s at 6 x I r and infinite (without overload
release)
Adjustable delay t sd
Steps: 0, 20, 60, 100, 200,
300, 500, 750, 1000 ms
1 off
41
1.3
Circuit-breakers, switch-disconnectors
Switch-disconnectors, 3 pole
PN..., N...
1
Rated current =
Rated uninterrupted
current
In = I u
A
Short-circuit
protection, max. fuse
gL-characteristic
Fixed mounting
with screw terminals
Part no.
Article no.
Fixed mounting
with box terminals
Part no.
Article no.
Price
See price
list
Price
See price
list
A gL
Switch-disconnectors
2 switch
positionsl , 0
63
125
100
125
125
125
160
160
160
250
200
250
250
250
400
630
630
630
Screw terminals as
accessories
PN2-160
266005
PN2-200
266006
PN2-250
266007
PN3-400
266017
PN3-630
266018
S
S
S
S
S
PN1-63
259140
PN1-100
259141
PN1-125
259142
PN1-160
281235
PN2-160-BT
110308
PN2-200-BT
110309
PN2-250-BT
110310
PN3-400-BT
110314
PN3-630-BT
110315
N1-63
259143
N1-100
259144
N1-125
259145
N1-160
281236
N2-160-BT
110311
N2-200-BT
110312
N2-250-BT
110313
N3-400-BT
110316
N3-630-BT
110317
B
B
B
B
B
B
B
B
3 switch positions I, +, 0
Can be remotely operated with shunt release XU/XA, remote operator XR,
Can be equipped with trip-indicating auxiliary contact M22-K..
42
63
125
100
125
125
125
160
160
160
250
200
250
250
250
400
630
630
630
800
1600
1000
1600
1250
1600
1600
1600
Screw terminals as
accessories
N2-160
266008
N2-200
266009
N2-250
266010
N3-400
266019
N3-630
266020
N4-800
266025
N4-1000
266026
N4-1250
266027
N4-1600
266028
S
S
S
S
S
S
S
S
S
Terminals as accessory
B
B
B
B
B
B
B
B
Circuit-breakers, switch-disconnectors
Switch-disconnectors, 3 pole
1.3
1
Plug-in/withdrawable units
Part no.
Article no.
Price
See price
list
Std. pack
1 off
N1-63-SVE
113729
N1-100-SVE
113730
N1-125-SVE
113731
1 off
Notes
B = box terminals
S = screw terminals
For further terminal types see accessories
IEC/EN 60947-3
Main switch characteristics including positive operation to IEC/EN 60204,
VDE 0113
Isolating characteristics to IEC/EN 60947-3, VDE 0660
Contact protection to VDE 0160 part 100
N2-160-SVE
113733
N2-200-SVE
113734
N2-250-SVE
113735
N3-400-AVE
110768
N3-630-AVE
110769
Withdrawable units as
accessories
43
1.3
Circuit-breakers, switch-disconnectors
Switch-disconnectors, 4 pole
PN...-4, N...-4
1
Rated current = Rated
uninterrupted current
In = I u
A
Short-circuit
protection, max. fuse
gL-characteristic
Fixed mounting
with screw terminals
Part no.
Article no.
Fixed mounting
with box terminals
Part no.
Article no.
Price
See price
list
Price
See price
A gL
Switch-disconnectors
2 switch
positionsl, 0
63
125
100
Screw terminals as
accessories
PN1-4-63
265999
125
PN1-4-100
266000
125
125
PN1-4-125
266001
160
160
PN1-4-160
281253
160
250
PN2-4-160-BT
118880
200
250
PN2-4-200-BT
118881
250
250
PN2-4-250-BT
118882
400
630
PN3-4-400-BT
111653
630
630
PN3-4-630-BT
111654
N1-4-63
266002
N1-4-100
266003
N1-4-125
266004
N1-4-160
281254
N2-4-160-BT
118883
N2-4-200-BT
118884
N2-4-250-BT
118885
N3-4-400-BT
111651
N3-4-630-BT
111652
PN2-4-160
266011
PN2-4-200
266012
PN2-4-250
266013
PN3-4-400
266021
PN3-4-630
266022
3 switch positions I, +, 0
Can be remotely operated with shunt release XU/XA, remote operator XR,
Can be equipped with trip-indicating auxiliary contact M22-K..
Screw terminals as
63
125
accessories
100
125
44
125
125
160
160
160
250
200
250
250
250
400
630
630
630
800
1600
1000
1600
1250
1600
1600
1600
N2-4-160
266014
N2-4-200
266015
N2-4-250
266016
N3-4-400
266023
N3-4-630
266024
N4-4-800
266029
N4-4-1000
266030
N4-4-1250
266031
N4-4-1600
266032
S
S
S
S
S
S
S
Terminals as accessory
B
B
B
B
B
B
B
B
Circuit-breakers, switch-disconnectors
Switch-disconnectors, 4 pole
1.3
1
Plug-in units
Part no.
Article no.
Price
See price
list
Std. pack
Notes
Order base
separately
B = box terminals
S = screw terminals
For further terminal types see accessories
1 off
1IEC/EN 60947-3
Main switch characteristics including positive operation to IEC/EN 60204,
VDE 0113
Isolating characteristics to IEC/EN 60947-3, VDE 0660
Contact protection to VDE 0160 part 100
1 off
N2-4-160-SVE
113736
N2-4-200-SVE
113737
N2-4-250-SVE
113738
N3-4-400-AVE
110872
N3-4-630-AVE
110873
Withdrawable units as
accessories
45
1.3
Circuit-breakers, switch-disconnectors
Technical overview for 1000 V
1 NZM...-S1, N...-S1
Circuit-breakers for 1000 V AC,
3 pole
Icu
I cs
Rated short-time
withstand current Icw
(0.1s currentrms)
46
10/0.5
3/0.5
15/0.5
10/0.5
20/0.3
15/0.3
10/0.5
3/0.5
20/0.3
15/0.3
15/0.5
10/0.5
20/0.3
15/0.3
Iu
Iu
Iu
Iu
Iu
Iu
Iu
Iu
Iu
Iu
NZMH2A...-S1
NZMH3AE...-S1
NZMH4AE...-S1
NZMH2VE...-S1
NZMH4VE...-S1
NZMH3ME...-S1
NZMH4-
N2-...-S1DC
N3-...-S1DC
N4-...-S1DC
20
25
32
40
50
63
80
100
125
160
200
250
300
250
400
630
630
800
1000
1250
1600
100
160
250
630
800
1000
1250
1600
220
350
450
550
875
1400
160
200
320
400
500
800
1000
1250
1400
25
kA
Circuit-breakers, switch-disconnectors
Circuit-breakers for 1000 V AC, 3 pole
Switching
capacity
1000 V
50/60 Hz
I cu
kA
Rated current =
Rated
uninterrupted
current
In = I u
A
Setting range
Overload
releases
Ir
A
Fixed mounting
Part no.
Article no.
Short-circuit releases
Non-delayed
Ii = I n x
Price
See price
list
1.3
1
Std. pack
Delayed
I sd = I r x
10
20
15-20
350 A fixed
25
20-25
350 A fixed
32
25-32
350 A fixed
40
32-40
8-10
50
40-50
6-10
63
50-63
6-10
80
63-80
6-10
100
80-100
6-10
125
100-125
6-10
160
125-160
6-10
200
160-200
6-10
250
200-250
6-10
300
240-300
6-10
Electronic releases
R.m.s. value measurement and thermal memory
15
250
125-250
20
Notes
2-11
400
200-400
2-11
630
315-630
2-8
630
315-630
2-12
800
400-800
2-12
1000
500-1000
2-12
1250
630-1250
2-12
1600
800-1600
2-12
NZMH2-A20-S1
290355
NZMH2-A25-S1
290356
NZMH2-A32-S1
290357
NZMH2-A40-S1
290358
NZMH2-A50-S1
290359
NZMH2-A63-S1
290360
NZMH2-A80-S1
290361
NZMH2-A100-S1
290362
NZMH2-A125-S1
290363
NZMH2-A160-S1
290364
NZMH2-A200-S1
290365
NZMH2-A250-S1
290366
NZMH2-A300-S1
107577
1 off
S
S
S
S
S
S
S
S
S
S
S
S
NZMH3-AE250-S1
119361
NZMH3-AE400-S1
119362
NZMH3-AE630-S1
119363
NZMH4-AE630-S1
290370
NZMH4-AE800-S1
290371
NZMH4-AE1000-S1
290372
NZMH4-AE1250-S1
290373
NZMH4-AE1600-S1
290374
1 off
S
S
S
S
S
S
B = box terminals
S = screw terminals
IEC/EN 60947-2
Terminal type:
NZM2: Cover NZM2-XKSA required
NZM3: Cover NZM3-XKSA required
NZM4: Isolated bar connection (screw terminal NZM4-XKS)
47
1.3
Circuit-breakers, switch-disconnectors
Circuit-breakers for 1000 V AC, 3 pole
Fixed mounting
Part no.
Article no.
1
Switching
capacity
1000 V
50/60 Hz
I cu
kA
Rated current =
Rated
uninterrupted
current
In = I u
A
Setting range
Overload
releases
Ir
A
Short-circuit releases
Non-delayed
Ii = I n x
15
20
Notes
48
160
80-160
1920 A fixed
2-10
250
125-250
3000 A fixed
2-10
400
200-400
2-11
2-10
630
315-630
2-8
1.5-7
630
315-630
2-12
2-10
800
400-800
2-12
2-10
1000
500-1000
2-12
2-10
1250
630-1250
2-12
2-10
1600
800-1600
2-12
2-10
220
1 10-220
2-14
350
175-350
2-14
450
225-450
2-12
550
275-550
2-14
875
438-875
2-14
1400
700-1400
2-14
B = box terminals
S = screw terminals
NZMH2-VE100-S1
100777
NZMH2-VE160-S1
100778
NZMH2-VE250-S1
100779
NZMH3-VE400-S1
119367
NZMH3-VE630-S1
119368
NZMH4-VE630-S1
290375
NZMH4-VE800-S1
290376
NZMH4-VE1000-S1
290377
NZMH4-VE1250-S1
290378
NZMH4-VE1600-S1
290379
NZMH3-ME220-S1
119364
NZMH3-ME350-S1
119365
NZMH3-ME450-S1
119366
NZMH4-ME550-S1
290383
NZMH4-ME875-S1
290384
NZMH4-ME1400-S1
290385
Terminal type:
NZM2: Cover NZM2-XKSA required
NZM3: Cover NZM3-XKSA required
NZM4: Isolated bus connection (screw terminal NZM4-XKS)
Std. pack
Delayed
I sd = I r x
20
Price
See price
list
1 off
S
S
S
S
S
S
S
S
S
S
S
S
1 off
1.3
Circuit-breakers, switch-disconnectors
Switch-disconnectors for 1000 V DC, 2 pole
N...DC
Fixed mounting
Switch-disconnectors
for 1000 V DC
Price
See price
list
Rated current =
Rated
uninterrupted
current
In = I u
A
Short-circuit
protection,
max. fuse gRcharacteristic
160
200
200
200
320
500
N3-4-320-S1-DC
127734
400
500
N3-4-400-S1-DC
142267
500
500
N3-4-500-S1-DC
142268
800
1600
N4-4-800-S1-DC
119890
1000
1600
N4-4-1000-S1-DC
119891
1250
1600
N4-4-1250-S1-DC
119886
1400
1400
N4-4-1400-S1-DC
119887
Part no.
Article no.
1
Std. pack
Notes
A gR
1 off
N2-4-160-S1-DC
127732
N2-4-200-S1-DC
127733
Rated
operational
current
In
A
Number of
poles
Terminals as accessory
Switch can not be combined with plug-in/withdrawable
Degree of
protection
Part no.
Article no.
Price
Std. pack
See
price list
Jumper kits
Model contains parts for upper switch side for 4 pole switches,N...-S1-DC that are used as 2 pole switches for DC
The jumpers each connect two current paths in series.Incomer and outgoer at bottom or top, freely selectable.
1250 A: For 65 C ambient air temperature connection at bottom through module plates NZM4-4-XKM2S-1600.
200 at 65 C
4 pole/
Jumper kit with cover
N2-4-S1-DC
IP2X
NZM2-4-XKV2P
131730
160 at 70 C
2 pole
400 at 70 C
N3-320(400)-S1-DC
500 at 50 C
400 at 70 C
N3-400(500)-S1-DC
400 at 70 C
500 at 55 C
500 at 40 C
N3-400(500)-S1-DC
4 pole/
2 pole
IP2X
NZM3-4-XKV2P
131731
4 pole/
2 pole
IP00
NZM3-4-XKVI2P
142269
4 pole/
2 pole
IP1X
NZM3-4-XKV2P-K
142271
1 off
IP2X
N3-500-S1-DC
500 at 65 C
1400 at 40 C
1250 at 65 C
1400 at 65 C
4 pole/
2 pole
IP00
NZM3-4-XKVl2P-K
142270
N4-4-S1-DC
4 pole/
2 pole
IP2X
NZM4-4-XKV2P
119888
N4-4-1400-S1-DC
4 pole/
2 pole
IP00
NZM4-4-XKV2P1400
119905
49
Circuit-breakers, switch-disconnectors
1.3
Switch-disconnectors, ATEX
1 PN...ATEX
Number of
conductors
Rated current =
Rated
uninterrupted
current
In = I u
A
Switch-disconnectors for ATEX type
3 pole
125
2 switch
positions l, 0
Notes
50
Short-circuit
protection,
max. fuse
gL-characteristic
Fixed mounting
Part no.
Article no.
Price
See price
list
Std. pack
A gL
125
PN1-125/HIV/DA-SVD-SW/ATEX22
119386
160
160
PN1-160/HIV/DA-SVD-SW/ATEX22
119387
200
250
PN2-200/HIV/DA-SVD-SW/ATEX22
119388
240
250
PN2-250/HIV/DA-SVD-SW/ATEX22
119389
400
630
PN3-400/HIV/DA-SVD-SW/ATEX22
119410
630
630
PN3-630/HIV/DA-SVD-SW/ATEX22
119411
6 pole
160
160
2PN1-160/HIV/DA-SVD-SW/ATEX22
119418
6 pole
250
250
2PN2-250/HIV/DA-SVD-SW/ATEX22
119419
3 pole
125
125
PN1-125/HIV/DA-SVD-SW/EMV/ATEX22
119412
160
160
PN1-160/HIV/DA-SVD-SW/EMV/ATEX22
119413
200
250
PN2-200/HIV/DA-SVD-SW/EMV/ATEX22
119414
240
250
PN2-250/HIV/DA-SVD-SW/EMV/ATEX22
119415
400
630
PN3-400/HIV/DA-SVD-SW/EMV/ATEX22
119416
630
630
PN3-630/HIV/DA-SVD-SW/EMV/ATEX22
119417
Main switch characteristics including positive operation to IEC/EN 60204, VDE 0113.
Isolating characteristics to IEC/EN 60947-3, VDE 0660.
Protection against electric shock to VDE 0160 part 100.
ATEX = Atmosphres explosibles = explosive atmospheres
Eaton supplies switch-disconnectors PN1, PN2 and PN3 for a current range of up to 630 A as complete device according
to ATEX Directive 94/9 EG (binding as of 06/2003).
The switches are approved for device group II, the application everything, except for mining and for category 3
(normal safety).
Switch-disconnectors in surface mounting enclosure with ATEX approval are used in potentially explosive dust-laden
areas, such as mills, metal grinding works, wood processing operations, cement works, the aluminum industry, the
foodstuffs industry, grain storage and processing plants, agriculture, and in the pharmaceuticals industry.
ATEX switches for EMC are suitable for use with screened cables.
For important general flush mounting and application notes, see the included installation instructions AWA1230-2480,
which you can also download from our homepage www.moeller.net.
1 off
Circuit-breakers, switch-disconnectors
Mechanical interlock for (door-coupling) rotary handles
1.4
1
51
Circuit-breakers, switch-disconnectors
1.4
240 V 60 Hz
480 V 60 Hz
600 V 60 Hz
400/415 V
440 V
sym. rms kA
sym. rms kA
sym. rms kA
kA/p.f
kA/p.t
NZMB2-...-NA
35
252)
0.25
25
0.25
25
NZMN1--NA
85
352)
0.25
50
0.25
35
0.30
20
0.50
10
NZMB2-...-NA
35
25
184)
0.25
25
0.25
25
NZMN2-...-NA
85
35
254)
0.25
50
0.25
35
0.25
25
0.30
20
NZMH2-..: NA
150
100
653)4)
150
0.20
130
0.20
50
0.25
20
0.30
52
A d ju s ta b le
Iu
A
NZM1
20-125
Ir
A
NZM2
20-250
0.8-1 x In
None
Iu
A
NZM1
1.2-100
NZM2
1.6-250
Circuit-breakers, switch-disconnectors
1.5
1
Electronic releases
Overload release
Iu
A
150-250
Iu
A
100-250
Short-circuit releases
Ir
A
0.51x1n
Iu
A
90-220
NZMN2-...E...-NA
85
35
254)
0.25
50
0.25
35
0.25
25
0.30
20
NZMH2-...E...-NA
150
100
504)
0.20
150
0.20
130
0.25
50
0.30
20
Iu
Iu
A
A
250-600 250-600
Ir
A
0.51x1n
Iu
Iu
A
A
220-450 6001200
NZMN3-...E...-NA
85
42
35
0.25
50
0.25
35
0.25
25
0.30
20
NZMH3-...E...-NA
150
100
50
0.20
150
0.20
130
0.25
65
0.25
35
Iu
A
8001200
Ir
A
0.51x1n
I sd
A
210x1n
Ii
A
212x1n
Motor protection
Ii
A
214x1n
NZMN4-...E...-NA
85
42
35
0.25
50
0.25
35
0.25
25
0.30
20
NZMH4-...E...-NA
125
85
50
0.20
85
0.20
85
0.25
65
0.25
50
The approved switches are suitable for world-wide use. The UL and CSA certificates can be found at www.ul.com and www.csa.com
UL certificates: File No.:E 31593(NZM1-4), E 148671 (NIS11-4)
CSA certificates: File No.165628(NZM1-4)
Molded case switch
UL/CSA approved to UL 489, CSA 22.2 No. 5-09
as well as IEC/EN 60947-2 Annex L
With main switch characteristics to IEC/EN 60204, VDE 0113
Isolating characteristics to IEC/EN 60947
Without overcurrent protection
With short-circuit release
Rated uninterrupted current Iu = I n
Switching capacity
according to UL 489, CSA 22.2
SCCR
IEC/EN 60947
Notes
240 V
480 V
600 V
400/415 V
440 V
525 V
690
1)
4)
63
100
125
160
200
250
400
600
800
1000
1200
NS1-...-NA
85
351)
50
35
20
10
NS1-...-NA
150
100
504)
150
130
50
20
NS1-...-NA
150
100
50
150
130
65
35
NS1-...-NA
85
65
42
70
65
40
35
53
Circuit-breakers, switch-disconnectors
1.5
Switching capacity
SCCR 480Y/ SCCR 480 V
277 V 60 Hz
60 Hz
SCCR 600Y/
347 V 60 Hz
SCCR 600 V
60 Hz
I cu
kA
I cu
kA
I cu
kA
I cu
kA
Rated current =
Rated
uninterrupted
current
In = I u
kA
Setting range
Overload
releases
Fixed
Ir
A
Short-circuit
releases
Non-delayed
Ii = I n x
A
Fixed mounting
Part no.
Article no.
Price
See price
list
I
System and cable protection
25
20
20
350 A fixed
25
25
350 A fixed
30
30
350 A fixed
35
35
Approx. 8-10
40
40
Approx. 8-10
45
45
Approx. 6-10
50
50
Approx. 6-10
60
60
Approx. 6-10
70
70
Approx. 6-10
80
80
Approx. 6-10
90
90
Approx. 6-10
100
100
Approx. 6-10
110
110
Approx. 6-10
125
125
Approx. 6-10
15
15
350 A fixed
20
20
350 A fixed
25
25
350 A fixed
30
30
350 A fixed
35
35
Approx. 8-10
40
40
Approx. 8-10
45
45
Approx. 6-10
50
50
Approx. 6-10
60
60
Approx. 6-10
70
70
Approx. 6-10
80
80
Approx. 6-10
90
90
Approx. 6-10
100
100
Approx. 6-10
110
110
Approx. 6-10
125
125
Approx. 6-10
150
150
Approx. 6-10
Screw terminals as
accessories
25
54
25
18
NZMB2-AF15-NA
269142
NZMB2-AF20-NA
269143
NZMB2-AF25-NA
269144
NZMB2-AF30-NA
269145
NZMB2-AF35-NA
269146
NZMB2-AF40-NA
269147
NZMB2-AF45-NA
269148
NZMB2-AF50-NA
269149
NZMB2-AF60-NA
269160
NZMB2-AF70-NA
269161
NZMB2-AF80-NA
269162
NZMB2-AF90-NA
269163
NZMB2-AF100-NA
269164
NZMB2-AF110-NA
269165
NZMB2-AF125-NA
269166
NZMB2-AF150-NA
269167
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Circuit-breakers, switch-disconnectors
Fixed mounting
with box terminals
Part no.
Article no.
NZMB1-AF20-NA
281554
NZMB1-AF25-NA
281555
NZMB1-AF30-NA
281556
NZMB1-AF35-NA
272204
NZMB1-AF40-NA
272205
NZMB1-AF45-NA
272206
NZMB1-AF50-NA
272207
NZMB1-AF60-NA
272208
NZMB1-AF70-NA
272209
NZMB1-AF80-NA
272250
NZMB1-AF90-NA
272251
NZMB1-AF100-NA
272252
NZMB1-AF110-NA
281557
NZMB1-AF125-NA
281558
NZMB2-AF15-BT-NA
107611
NZMB2-AF20-BT-NA
107612
NZMB2-AF25-BT-NA
107613
NZMB2-AF30-BT-NA
107614
NZMB2-AF35-BT-NA
107615
NZMB2-AF40-BT-NA
107616
NZMB2-AF45-BT-NA
107617
NZMB2-AF50-BT-NA
107618
NZMB2-AF60-BT-NA
107619
NZMB2-AF70-BT-NA
107620
NZMB2-AF80-BT-NA
107621
NZMB2-AF90-BT-NA
107622
NZMB2-AF100-BT-NA
107623
NZMB2-AF110-BT-NA
107624
NZMB2-AF125-BT-NA
107625
NZMB2-AF150-BT-NA
107626
Price
See price
list
1.5
Std. pack
Notes
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Current Limiting CB
Max. Voltage Rating
Degree of Protection
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Current Limiting CB
Max. Voltage Rating
Degree of Protection
B
B
B
B
B
B
B
B
B
55
Circuit-breakers, switch-disconnectors
1.5
I cu
kA
I cu
kA
SCCR 600Y/
347 V 60 Hz
SCCR 600 V
60 Hz
I cu
kA
I cu
kA
Rated current =
Rated
uninterrupted
current
In = I u
kA
Setting range
Overload
releases
Fixed
Ir
A
Short-circuit
releases
Non-delayed
Ii = I n x
A
Part no.
Article no.
Price
See price
list
I
System and cable protection
Basic switching
capacity
Normal switching
capacity
35
18
175
175
Approx. 6-10
NZMB2-AF175-NA
269168
NZMB2-AF200-NA
269169
NZMB2-AF225-NA
271089
NZMB2-AF250-NA
271100
Screw terminals as
accessories
200
200
Approx. 6-10
225
225
Approx. 6-10
250
250
Approx. 6-10
20
20
350 A fixed
25
25
350 A fixed
30
30
350 A fixed
35
35
Approx. 8-10
40
40
Approx. 8-10
45
45
Approx. 6-10
50
50
Approx. 6-10
60
60
Approx. 6-10
70
70
Approx. 6-10
80
80
Approx. 6-10
90
90
Approx. 6-10
100
100
Approx. 6-10
110
110
Approx. 6-10
125
125
Approx. 6-10
15
15
350 A fixed
20
20
350 A fixed
25
25
350 A fixed
30
30
350 A fixed
35
35
Approx. 8-10
40
40
Approx. 8-10
45
45
Approx. 6-10
50
50
Approx. 6-10
60
60
Approx. 6-10
70
70
Approx. 6-10
s
s
s
s
s
S
S
S
S
35
56
35
25
NZMN2-AF15-NA
269170
NZMN2-AF20-NA
269171
NZMN2-AF25-NA
269172
NZMN2-AF30-NA
269173
NZMN2-AF35-NA
269174
NZMN2-AF40-NA
269175
NZMN2-AF45-NA
269176
NZMN2-AF50-NA
269177
NZMN2-AF60-NA
269178
NZMN2-AF70-NA
269179
S
S
S
S
S
S
S
S
S
S
Circuit-breakers, switch-disconnectors
Circuit-breakers UL/CSA, IEC,
Fixed mounting
with box terminals
Part no.
Article no.
Price
See price
list
Std. pack
NZMB2-AF175-BT-NA
107627
NZMB2-AF200-BT-NA
107628
NZMB2-AF225-BT-NA
107629
NZMB2-AF250-BT-NA
107630
NZMN1-AF20-NA
281565
NZMN1-AF25-NA
281566
NZMN1-AF30-NA
281567
NZMN1-AF35-NA
274220
NZMN1-AF40-NA
274223
NZMN1-AF45-NA
274230
NZMN1-AF50-NA
274231
NZMN1-AF60-NA
274232
NZMN1-AF70-NA
274233
NZMN1-AF80-NA
274234
NZMN1-AF90-NA
274235
NZMN1-AF100-NA
274236
NZMN1-AF110-NA
281568
NZMN1-AF125-NA
281569
NZMN2-AF15-BT-NA
107631
NZMN2-AF20-BT-NA
107632
NZMN2-AF25-BT-NA
107633
NZMN2-AF30-BT-NA
107634
NZMN2-AF35-BT-NA
107635
NZMN2-AF40-BT-NA
107636
NZMN2-AF45-BT-NA
107637
NZMN2-AF50-BT-NA
107638
NZMN2-AF60-BT-NA
107639
NZMN2-AF70-BT-NA
107640
1 off
B
B
B
1 off
B=box terminals
S=screw terminals
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Current Limiting CB
Max. Voltage Rating
Degree of Protection
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Current Limiting CB
Max. Voltage Rating
Degree of Protection
B
B
B
B
B
1.5
1
Notes
B
B
B
B
B
B
B
B
B
B
B
B
B
B
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Current Limiting CB
Max. Voltage Rating
Degree of Protection
B
B
B
57
Circuit-breakers, switch-disconnectors
1.5
Switching capacity
SCCR 480Y/ SCCR 480 V
277 V 60 Hz
60 Hz
SCCR 600Y/
347 V 60 Hz
SCCR 600 V
60 Hz
I cu
kA
I cu
kA
I cu
kA
I cu
kA
Rated current =
Rated
uninterrupted
current
In = I u
kA
Setting range
Overload
releases
Fixed
Ir
A
Short-circuit
releases
Non-delayed
Ii = I n x
A
Fixed mounting
Part no.
Article no.
Price
See price
list
I
System and cable protection
Fixed overload releases Ir
Basic switching
capacity
High switching
capacity
35
25
100
58
35
25
100
25
18
50
80
80
Approx. 6-10
90
90
Approx. 6-10
100
100
Approx. 6-10
110
110
Approx. 6-10
125
125
Approx. 6-10
150
150
Approx. 6-10
175
175
Approx. 6-10
200
200
Approx. 6-10
225
225
Approx. 6-10
250
250
Approx. 6-10
15
15
350 A fixed
20
20
350 A fixed
25
25
350 A fixed
30
30
350 A fixed
35
35
Approx. 8-10
40
40
Approx. 8-10
45
45
Approx. 6-10
50
50
Approx. 6-10
60
60
Approx. 6-10
70
70
Approx. 6-10
80
80
Approx. 6-10
90
90
Approx. 6-10
100
100
Approx. 6-10
110
110
Approx. 6-10
125
125
Approx. 6-10
150
150
Approx. 6-10
175
175
Approx. 6-10
200
200
Approx. 6-10
225
225
Approx. 6-10
250
250
Approx. 6-10
NZMN2-AF80-NA
269180
NZMN2-AF90-NA
269181
NZMN2-AF100-NA
269182
NZMN2-AF110-NA
269183
NZMN2-AF125-NA
269184
NZMN2-AF150-NA
269185
NZMN2-AF175-NA
269186
NZMN2-AF200-NA
269187
NZMN2-AF225-NA
271101
NZMN2-AF250-NA
271102
NZMH2-AF15-NA
269188
NZMH2-AF20-NA
269189
NZMH2-AF25-NA
269190
NZMH2-AF30-NA
269191
NZMH2-AF35-NA
269192
NZMH2-AF40-NA
269193
NZMH2-AF45-NA
269194
NZMH2-AF50-NA
269195
NZMH2-AF60-NA
269196
NZMH2-AF70-NA
269197
NZMH2-AF80-NA
269198
NZMH2-AF90-NA
269199
NZMH2-AF100-NA
269200
NZMH2-AF110-NA
269201
NZMH2-AF125-NA
269202
NZMH2-AF150-NA
269203
NZMH2-AF175-NA
269204
NZMH2-AF200-NA
269205
NZMH2-AF225-NA
271103
NZMH2-AF250-NA
271104
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Circuit-breakers, switch-disconnectors
Fixed mounting
with box terminals
Part no.
Article no.
1.5
1
Price
See price
list
NZMN2-AF80-BT-NA
107641
NZMN2-AF90-BT-NA
107642
NZMN2-AF100-BT-NA
107643
NZMN2-AF110-BT-NA
107644
NZMN2-AF125-BT-NA
107645
NZMN2-AF150-BT-NA
107646
NZMN2-AF175-BT-NA
107647
NZMN2-AF200-BT-NA
107648
NZMN2-AF225-BT-NA
107649
NZMN2-AF250-BT-NA
107650
NZMH2-AF15-BT-NA
107809
NZMH2-AF20-BT-NA
107810
NZMH2-AF25-BT-NA
107811
NZMH2-AF30-BT-NA
107812
NZMH2-AF35-BT-NA
107813
NZMH2-AF40-BT-NA
107814
NZMH2-AF45-BT-NA
107815
NZMH2-AF50-BT-NA
107816
NZMH2-AF60-BT-NA
107817
NZMH2-AF70-BT-NA
107818
NZMH2-AF80-BT-NA
107819
NZMH2-AF90-BT-NA
107820
NZMH2-AF100-BT-NA
107821
NZMH2-AF110-BT-NA
107822
NZMH2-AF125-BT-NA
107823
NZMH2-AF150-BT-NA
107824
NZMH2-AF175-BT-NA
107825
NZMH2-AF200-BT-NA
107826
NZMH2-AF225-BT-NA
107827
NZMH2-AF250-BT-NA
107828
Std. pack
Notes
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Current Limiting CB
Max. Voltage Rating
Degree of Protection
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Current Limiting CB
Max. Voltage Rating
Degree of Protection
B
B
B
B
B
B
B
B
B
B
B
B
59
Circuit-breakers, switch-disconnectors
1.5
NZM...A...NA
Switching capacity
SCCR 480Y/ SCCR 480 V
277 V 60 Hz
60 Hz
I cu
kA
I cu
kA
SCCR 600Y/
347 V 60 Hz
SCCR 600 V
60 Hz
I cu
kA
I cu
kA
Rated current =
Rated
uninterrupted
current
In = I u
kA
Setting range
Overload
releases
Fixed
Ir
A
Short-circuit
releases
Non-delayed
Ii = I n x
A
Fixed mounting
Part no.
Article no.
Price
See price
list
I
System and cable protection
Fixed overload releases Ir
Basic switching
capacity
Basic switching
capacity
Basic switching
capacity
60
35
25
35
35
25
25
18
20
15-20
350 A fixed
Screw terminals as
accessories
25
20-25
350 A fixed
32
25-32
350 A fixed
40
32-40
8-10
50
40-50
6-10
63
50-63
6-10
80
63-80
6-10
100
80-100
6-10
125
100-125
6-10
20
15-20
350 A fixe
NZMB2-A20-NA
269206
25
20-25
350 A fixe
NZMB2-A25-NA
269207
32
25-32
350 A fixe
NZMB2-A32-NA
269208
40
32-40
8-10
NZMB2-A40-NA
269209
50
40-50
6-10
NZMB2-A50-NA
269210
63
50-63
6-10
NZMB2-A63-NA
269211
80
63-80
6-10
NZMB2-A80-NA
269212
100
80-100
6-10
NZMB2-A100-NA
269213
125
100-125
6-10
NZMB2-A125-NA
269214
160
125-160
6-10
NZMB2-A160-NA
269215
200
160-200
6-10
NZMB2-A200-NA
269216
250
200-250
6-10
NZMB2-A250-NA
271105
20
15-20
350 A fixed
Screw terminals as
accessories
25
20-25
350 A fixed
32
25-32
350 A fixed
40
32-40
8-10
50
40-50
6-10
63
50-63
6-10
Circuit-breakers, switch-disconnectors
Circuit-breakers UL/CSA, IEC, thermomagnetic releases, 3 pole
1.5
1
Fixed mounting
with box terminals
Part no.
Article no.
Price
See price
list
NZMB1-A20-NA
281559
NZMB1-A25-NA
281560
NZMB1-A32-NA
281561
NZMB1-A40-NA
272253
NZMB1-A50-NA
272254
NZMB1-A63-NA
272255
NZMB1-A80-NA
272256
NZMB1-A100-NA
272258
NZMB1-A125-NA
281562
NZMB2-A20-BT-NA
107773
NZMB2-A25-BT-NA
107774
NZMB2-A32-BT-NA
107775
NZMB2-A40-BT-NA
107776
NZMB2-A50-BT-NA
107777
NZMB2-A63-BT-NA
107778
NZMB2-A80-BT-NA
107779
NZMB2-A100-BT-NA
107780
NZMB2-A125-BT-NA
107781
NZMB2-A160-BT-NA
107782
NZMB2-A200-BT-NA
107783
NZMB2-A250-BT-NA
107784
NZMN1-A20-NA
281570
NZMN1-A25-NA
281571
NZMN1-A32-NA
281572
NZMN1-A40-NA
274237
NZMN1-A50-NA
274239
NZMN1-A63-NA
274240
Std. pack
Notes
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Current Limiting CB
Max. Voltage Rating
Degree of Protection
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Current Limiting CB
Max. Voltage Rating
Degree of Protection
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Current Limiting CB
Max. Voltage Rating
Degree of Protection
61
Circuit-breakers, switch-disconnectors
1.5
NZM...A...NA
Switching capacity
SCCR 480Y/ SCCR 480 V
277 V 60 Hz
60 Hz
SCCR 600Y/
347 V 60 Hz
SCCR 600 V
60 Hz
I cu
kA
I cu
kA
I cu
kA
I cu
kA
Rated current =
Rated
uninterrupted
current
In = I u
kA
Setting range
Overload
releases
Fixed
Ir
A
Short-circuit
releases
Non-delayed
Ii = I n x
A
Fixed mounting
Part no.
Article no.
Price
See price
list
I
System and cable protection
Basic switching
capacity
35
High switching
capacity
150
100
62
35
150
100
25
65
50
Screw terminals as
accessories
80
63-80
6-10
100
80-100
6-10
125
100-125
6-10
20
15-20
350 A fixed
NZMN2-A20-NA
269217
25
20-25
350 A fixed
NZMN2-A25-NA
269218
32
25-32
350 A fixed
NZMN2-A32-NA
269219
40
32-40
8-10
NZMN2-A40-NA
269220
50
40-50
6-10
NZMN2-A50-NA
269221
63
50-63
6-10
NZMN2-A63-NA
269222
80
63-80
6-10
NZMN2-A80-NA
269223
100
80-100
6-10
NZMN2-A100-NA
269224
125
100-125
6-10
NZMN2-A125-NA
269225
160
125-160
6-10
NZMN2-A160-NA
269226
200
160-200
6-10
NZMN2-A200-NA
269227
250
200-250
6-10
NZMN2-A250-NA
271106
20
15-20
350 A fixed
NZMH2-A20-NA
269228
25
20-25
350 A fixed
NZMH2-A25-NA
269229
32
25-32
350 A fixed
NZMH2-A32-NA
269230
40
32-40
8-10
NZMH2-A40-NA
269231
50
40-50
6-10
NZMH2-A50-NA
269232
63
50-63
6-10
NZMH2-A63-NA
269233
80
63-80
6-10
NZMH2-A80-NA
269234
100
80-100
6-10
NZMH2-A100-NA
269235
125
100-125
6-10
NZMH2-A125-NA
269236
160
125-160
6-10
NZMH2-A160-NA
269237
200
160-200
6-10
NZMH2-A200-NA
269238
250
200-250
6-10
NZMH2-A250-NA
271107
Circuit-breakers, switch-disconnectors
Mechanical interlock for (door-coupling) rotary handles
1.5
1
Fixed mounting
with box terminals
Part no.
Article no.
Price
See price
list
NZMN1-A80-NA
274241
NZMN1-A100-NA
274242
NZMN1-A125-NA
281573
NZMN2-A20-BT-NA
107785
NZMN2-A25-BT-NA
107786
NZMN2-A32-BT-NA
107787
NZMN2-A40-BT-NA
107788
NZMN2-A50-BT-NA
107789
NZMN2-A63-BT-NA
107790
NZMN2-A80-BT-NA
107791
NZMN2-A100-BT-NA
107792
NZMN2-A125-BT-NA
107793
NZMN2-A160-BT-NA
107794
NZMN2-A200-BT-NA
107795
NZMN2-A250-BT-NA
107796
NZMH2-A20-BT-NA
107797
NZMH2-A25-BT-NA
107798
NZMH2-A32-BT-NA
107799
NZMH2-A40-BT-NA
107800
NZMH2-A50-BT-NA
107801
NZMH2-A63-BT-NA
107802
NZMH2-A80-BT-NA
107803
NZMH2-A100-BT-NA
107804
NZMH2-A125-BT-NA
107805
NZMH2-A160-BT-NA
107806
NZMH2-A200-BT-NA
107807
NZMH2-A250-BT-NA
107808
Std. pack
1 off
B=boxterminals
S=screw terminals
Product Standards
Notes
Product Standards
63
Circuit-breakers, switch-disconnectors
1.5
Fixed mounting
NZM...AF...NA
Rated current =
Setting range
SCCR
600 V
60 Hz
Rated
uninterrupted
current
Overload
releases
I cu
kA
In = I u
A
Ir
A
Switching capacity
SCCR
480Y/
277 V
60 Hz
I cu
kA
SCCR
480 V
60 Hz
I cu
kA
SCCR
600Y/
347 V
60 Hz
I cu
kA
Short-circuit
releases
Nondelayed
Ii = I n x
Part no.
Price
Article no.
See price
list
Std. pack
I
System and cable protection
Normal switching
capacity
250
2-11
NZMN3-AEF250-NA
269275
300
300
2-11
NZMN3-AEF300-NA
269276
350
350
2-11
NZMN3-AEF350-NA
269277
400
400
2-11
NZMN3-AEF400-NA
269278
450
450
2-8
NZMN3-AEF450-NA
269279
500
500
2-8
NZMN3-AEF500-NA
269280
550
550
2-8
NZMN3-AEF550-NA
269281
600
600
2-8
NZMN3-AEF600-NA
269282
600
600
2-12
NZMN4-AEF600-NA
271108
700
700
2-12
NZMN4-AEF700-NA
271109
800
800
2-12
NZMN4-AEF800-NA
271110
900
900
2-12
NZMN4-AEF900-NA
271111
1000
1000
2-12
NZMN4-AEF1000-NA
271112
1200
1200
2-12
250
250
2-11
NZMN4-AEF1200-NA
271113
NZMH3-AEF250-NA
269283
300
300
2-11
NZMH3-AEF300-NA
269284
350
350
2-11
NZMH3-AEF350-NA
269285
400
400
2-11
NZMH3-AEF400-NA
269286
450
450
2-8
NZMH3-AEF450-NA
269287
500
500
2-8
NZMH3-AEF500-NA
269288
550
550
2-8
NZMH3-AEF550-NA
269289
600
600
2-8
NZMH3-AEF600-NA
269290
600
600
2-12
NZMH4-AEF600-NA
271114
700
700
2-12
NZMH4-AEF700-NA
271115
800
800
2-12
NZMH4-AEF800-NA
271116
900
900
2-12
NZMH4-AEF900-NA
271117
1000
1000
2-12
NZMH4-AEF1000-NA
271118
1200
1200
2-12
NZMH4-AEF1200-NA
271119
42
High switching
capacity
100
85
64
42
100
85
35
50
50
35
50
50
1 off
1 off
1.5
Circuit-breakers, switch-disconnectors
Circuit-breakers UL/CSA, IEC, electronic releases, 3 pole
Fixed mounting
Switching capacity
Setting range
SCCR
600 V
60 Hz
Rated current =
Rated
uninterrupted
current
SCCR
480Y/
277 V
60 Hz
SCCR
480 V
60 Hz
SCCR
600Y/
347 V
60 Hz
Overload
releases
I cu
I cu
I cu
I cu
In = I u
Ir
kA
kA
kA
kA
Short-circuit
releases
Nondelayed
Ii = I n x
Part no.
Article no.
Price
See price
list
Std. pack
I
System and cable protection
Normal switching
capacity
125-250
2-11
400
200-400
2-11
600
300-600
2-8
800
400-800
1000
1200
42
100
85
Notes
42
100
85
35
50
50
35
50
50
NZMN3-AE250-NA
269299
NZMN3-AE400-NA
269300
NZMN3-AE600-NA
269301
2-12
NZMN4-AE800-NA
271120
500-1000
2-12
NZMN4-AE1000-NA
271121
600-1200
2-12
NZMN4-AE1200-NA
271122
250
125-250
2-11
NZMH3-AE250-NA
269302
400
200-400
2-11
NZMH3-AE400-NA
269303
600
300-600
2-8
NZMH3-AE600-NA
269304
800
400-800
2-12
1000
500-1000
2-12
1200
600-1200
2-12
NZMH4-AE800-NA
271123
NZMH4-AE1000-NA
271124
NZMH4-AE1200-NA
271125
1 off
1 off
S
S
65
1.5
Circuit-breakers, switch-disconnectors
Circuit-breakers UL/CSA, IEC, electronic releases, 3 pole
NZM...VEF...NA
Fixed mounting
Rated current =
Setting range
SCCR
480Y/
277 V
60 Hz
Switching capacity
SCCR
480 V
60 Hz
SCCR
600Y/
347 V
60 Hz
SCCR
600 V
60 Hz
Rated
uninterrupted
current
Overload
releases
Fixed
Short-circuit releases
Nondelayed
Delayed
I cu
kA
I cu
kA
I cu
kA
I cu
kA
In = I u
A
Ir
A
I i = I n x...
I sd = I r x
Part no.
Article no.
Price
See price
list
Normal switching
capacity
Normal switching
capacity
66
35
42
42
35
42
42
25
35
35
35
35
150
150
1800 A
2-10
NZMN2-VEF150-NA
271126
175
175
2100 A
2-10
200
200
2400 A
2-10
NZMN2-VEF175-NA
271127
NZMN2-VEF200-NA
271128
225
225
2700 A
2-10
NZMN2-VEF225-NA
271129
250
250
3000 A
2-10
NZMN2-VEF250-NA
271130
250
250
2-11
2-10
NZMN3-VEF250-NA
269308
300
300
2-11
2-10
NZMN3-VEF300-NA
269309
350
350
2-11
2-10
NZMN3-VEF350-NA
269310
400
400
2-11
2-10
NZMN3-VEF400-NA
269311
450
450
2-8
1.5-7
NZMN3-VEF450-NA
269312
500
500
2-8
1.5-7
NZMN3-VEF500-NA
269313
550
550
2-8
1.5-7
NZMN3-VEF550-NA
269314
600
600
2-8
1.5-7
NZMN3-VEF600-NA
269315
600
600
2-12
2-10
NZMN4-VEF600-NA
271136
700
700
2-12
2-10
NZMN4-VEF700-NA
271137
800
800
2-12
2-10
NZMN4-VEF800-NA
271138
900
900
2-12
2-10
NZMN4-VEF900-NA
271139
1000
1000
2-12
2-10
NZMN4-VEF1000-NA
271140
1200
1200
2-12
2-10
NZMN4-VEF1200-NA
271141
Circuit-breakers, switch-disconnectors
Circuit-breakers UL/CSA, IEC, electronic releases, 3 pole
1.5
1
Fixed mounting
with box terminals
Part no.
Article no.
Price
See price
list
NZMN2-VEF150-BT-NA
107593
NZMN2-VEF175-BT-NA
107594
NZMN2-VEF200-BT-NA
107595
NZMN2-VEF225-BT-NA
107596
NZMN2-VEF250-BT-NA
107597
Terminals as accessory
Std. pack
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Current Limiting CB
Max. Voltage Rating
Degree of Protection
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Current Limiting CB
Max. Voltage Rating
Degree of Protection
Terminals as accessory
Notes
1 off
67
Circuit-breakers, switch-disconnectors
1.5
Fixed mounting
NZM...VEF...NA
Switching capacity
SCCR
480Y/
277 V
60 Hz
I cu
kA
Rated current =
Setting range
SCCR
600 V
60 Hz
Rated
uninterrupted
current
Overload
releases
Fixed
I cu
SCCR
600Y/
347 V
60 Hz
I cu
I cu
In = I u
Ir
kA
kA
kA
SCCR
480 V
60 Hz
Part no.
Short-circuit releases
Nondelayed
Ii = I n x
Article no.
Price
See price
list
Delayed
I sd = I r x
100
100
85
100
100
85
50
50
50
150
150
175
175
200
200
225
225
250
250
50
250
50
250
1800 A
fixed
2100 A
fixed
2400 A
fixed
2700 A
fixed
3000 A
fixed
2-11
2-10
300
300
2-11
2-10
350
350
2-11
2-10
400
400
2-11
2-10
450
450
2-8
1.5-7
500
500
2-8
1.5-7
550
550
2-8
1.5-7
600
600
2-8
1.5-7
600
600
2-12
2-10
700
700
2-12
2-10
800
800
2-12
2-10
900
900
2-12
2-10
1000
1000
2-12
2-10
1200
1200
2-12
2-10
68
2-10
2-10
2-10
2-10
2-10
NZMH2-VEF150-NA
271131
NZMH2-VEF175-NA
271132
NZMH2-VEF200-NA
271133
NZMH2-VEF225-NA
271134
NZMH2-VEF250-NA
271135
NZMH3-VEF250-NA
269316
NZMH3-VEF300-NA
269317
NZMH3-VEF350-NA
269318
NZMH3-VEF400-NA
269319
NZMH3-VEF450-NA
269320
NZMH3-VEF500-NA
269321
NZMH3-VEF550-NA
269322
NZMH3-VEF600-NA
269323
NZMH4-VEF600-NA
271142
NZMH4-VEF700-NA
271143
NZMH4-VEF800-NA
271144
NZMH4-VEF900-NA
271145
NZMH4-VEF1000-NA
271146
NZMH4-VEF1200-NA
271147
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Circuit-breakers, switch-disconnectors
Circuit-breakers UL/CSA, IEC, electronic releases, 3 pole
Fixed mounting
with box terminals
Part no.
Article no.
NZMH2-VEF150-BT-NA
107598
NZMH2-VEF175-BT-NA
107599
NZMH2-VEF200-BT-NA
107840
NZMH2-VEF225-BT-NA
107841
NZMH2-VEF250-BT-NA
107842
Terminals as accessory
1.5
1
Price
See price
list
Std. pack
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Current Limiting CB
Max. Voltage Rating
Degree of Protection
B
B
B
B
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Current Limiting CB
Max. Voltage Rating
Degree of Protection
Notes
Terminals as accessory
69
Circuit-breakers, switch-disconnectors
1.5
Fixed mounting
Switching capacity
SCCR
480 V
60 Hz
SCCR
600Y/
347 V
60 Hz
SCCR
600 V
60 Hz
Rated current =
Rated
uninterrupted
current
Setting range
SCCR
480Y/
277 V
60 Hz
I cu
I cu
I cu
I cu
In = I u
Ir
kA
kA
kA
kA
Overload
releases
Short-circuit releases
Nondelayed
Ii = I n x
Part no.
Article no.
Price
See price
list
Delayed
I sd = I r x
35
42
42
High switching
capacity
100
100
85
70
35
42
42
100
100
85
25
35
35
50
50
50
100
50-100
160
80-160
250
125-250
35
250
125-250
2-11
2-10
400
200-400
2-11
2-10
600
300-600
2-8
1.5-7
800
400-800
2-12
2-10
1000
500-1000
2-12
2-10
1200
630-1200
2-12
2-10
100
50-100
2-10
160
80-160
250
125-250
1200 A
fixed
1920 A
fixed
3000 A
fixed
250
125-250
2-11
2-10
400
200-400
2-11
2-10
600
300-600
2-8
1.5-7
800
400-800
2-12
2-10
1000
500-1000
2-12
2-10
1200
630-1200
2-12
2-10
35
50
50
1200 A
fixed
1920 A
fixed
3000 A
fixed
2-10
2-10
2-10
2-10
2-10
NZMN2-VE100-NA
271148
NZMN2-VE160-NA
271149
NZMN2-VE250-NA
271150
NZMN3-VE250-NA
269332
NZMN3-VE400-NA
269333
NZMN3-VE600-NA
269334
NZMN4-VE800-NA
271154
NZMN4-VE1000-NA
271155
NZMN4-VE1200-NA
271156
NZMH2-VE100-NA
271151
NZMH2-VE160-NA
271152
NZMH2-VE250-NA
271153
NZMH3-VE250-NA
269335
NZMH3-VE400-NA
269336
NZMH3-VE600-NA
269337
NZMH4-VE800-NA
271157
NZMH4-VE1000-NA
271158
NZMH4-VE1200-NA
271159
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Circuit-breakers, switch-disconnectors
Circuit-breakers UL/CSA, IEC, electronic releases, 3 pole
Fixed mounting
with box terminals
Part no.
Article no.
NZMN2-VE100-BT-NA
107843
NZMN2-VE160-BT-NA
107844
NZMN2-VE250-BT-NA
107845
Price
See price
list
Std. pack
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Current Limiting CB
Max. Voltage Rating
Degree of Protection
B
B
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Current Limiting CB
Max. Voltage Rating
Degree of Protection
Terminals as accessory
Notes
Terminals as accessory
NZMH2-VE100-BT-NA
107846
NZMH2-VE160-BT-NA
107847
NZMH2-VE250-BT-NA
107848
1.5
B
B
B
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Current Limiting CB
Max. Voltage Rating
Degree of Protection
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Current Limiting CB
Max. Voltage Rating
Degree of Protection
71
1.5
Circuit-breakers, switch-disconnectors
Circuit-breakers UL/CSA, IEC magnetic short-circuit releases, 3 pole
NZM...-S...CNA
Rated current =
Rated uninterrupted current
In = I u
Setting range
Short-circuit releases
Non-delayed
Ii = I n x
Fixed mounting
with screw terminals
Part no.
Article no.
Price
See price
list
Short-circuit protection
Basic switching
capacity
72
6- 11
6- 11
6- 11
6- 11
12
7- 12
18
7- 12
26
8- 13
33
8- 14
40
8- 14
50
8- 14
63
8- 14
80
8- 14
100
8- 13
1.6
8- 14
2.4
8- 14
6- 11
6- 11
12
7- 12
18
7- 12
26
8- 13
33
8- 14
40
8- 14
50
8- 14
63
8- 14
80
8- 14
100
8- 14
125
8- 14
160
8- 14
200
8- 13
250
8- 10
NZMB2-S1.6-CNA
269472
NZMB2-S2.4-CNA
269473
NZMB2-S5-CNA
103034
NZMB2-S8-CNA
103035
NZMB2-S12-CNA
103036
NZMB2-S18-CNA
103037
NZMB2-S26-CNA
103038
NZMB2-S33-CNA
103039
NZMB2-S40-CNA
269243
NZMB2-S50-CNA
269244
NZMB2-S63-CNA
269245
NZMB2-S80-CNA
269246
NZMB2-S100-CNA
269247
NZMB2-S125-CNA
269248
NZMB2-S160-CNA
269249
NZMB2-S200-CNA
269250
NZMB2-S250-CNA
102478
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Circuit-breakers, switch-disconnectors
Circuit-breakers UL/CSA, IEC magnetic short-circuit releases, 3 pole
Fixed mounting
with box terminals
Part no.
Article no.
NZMB1-S1.2-CNA
102906
NZMB1-S2-CNA
102907
NZMB1-S3-CNA
102908
NZMB1-S5-CNA
102909
NZMB1-S8-CNA
103020
NZMB1-S12-CNA
103021
NZMB1-S18-CNA
103022
NZMB1-S26-CNA
103023
NZMB1-S33-CNA
103024
NZMB1-S40-CNA
281263
NZMB1-S50-CNA
281264
NZMB1-S63-CNA
281265
NZMB1-S80-CNA
281266
NZMB1-S100-CNA
281267
NZMB2-S1.6-BT-CNA
107651
NZMB2-S2.4-BT-CNA
107652
NZMB2-S5-BT-CNA
107653
NZMB2-S8-BT-CNA
107654
NZMB2-S12-BT-CNA
107655
NZMB2-S18-BT-CNA
107656
NZMB2-S26-BT-CNA
107657
NZMB2-S33-BT-CNA
107658
NZMB2-S40-BT-CNA
107659
NZMB2-S50-BT-CNA
107660
NZMB2-S63-BT-CNA
107661
NZMB2-S80-BT-CNA
107662
NZMB2-S100-BT-CNA
107663
NZMB2-S125-BT-CNA
107664
NZMB2-S160-BT-CNA
107665
NZMB2-S200-BT-CNA
107666
NZMB2-S250-BT-CNA
107667
Std. pack
Price
See price
list
1.5
Notes
1 off
Product Standards
1 off
Product Standards
B
B
B
B
B
B
B
B
B = box terminals
S = screw terminals
For further terminal types see
accessories
Switches correspond with both
UL/CSA and IEC regulations. IEC
switching performance values
shown on type label.
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
73
1.5
Circuit-breakers, switch-disconnectors
Circuit-breakers UL/CSA, IEC magnetic short-circuit releases, 3 pole
Fixed mounting
with screw terminals
Part no.
Article no.
NZM...-S...CNA
Rated current =
Rated uninterrupted current
In = I u
A
Setting range
Short-circuit releases
Non-delayed
Ii = I n x
Price
See price
list
Std. pack
I
Short-circuit protection
74
6- 11
6- 11
6- 11
6- 11
12
7- 12
18
7- 12
26
8- 13
33
8- 14
40
8- 14
50
8- 14
63
8- 14
80
8- 14
100
8- 13
1.6
8- 14
2.4
8- 14
6- 11
6- 11
12
7- 12
18
7- 12
26
8- 13
33
8- 14
40
8- 14
50
8- 14
63
8- 14
80
8- 14
100
8- 14
125
8- 14
160
8- 14
200
8- 13
250
8- 10
1)
2)
NZMN1-S1.2-CNA
103025
NZMN1-S2-CNA
103026
NZMN1-S3-CNA
103027
NZMN1-S5-CNA
103028
NZMN1-S8-CNA
103029
NZMN1-S12-CNA
103030
NZMN1-S18-CNA
103031
NZMN1-S26-CNA
103032
NZMN1-S33-CNA
103033
NZMN1-S40-CNA
281276
NZMN1-S50-CNA
281277
NZMN1-S63-CNA
281278
NZMN1-S80-CNA
281279
NZMN1-S100-CNA
281280
NZMN2-S1.6-CNA
269478
NZMN2-S2.4-CNA
269479
NZMN2-S5-CNA
103040
NZMN2-S8-CNA
103041
NZMN2-S12-CNA
103042
NZMN2-S18-CNA
103043
NZMN2-S26-CNA
103044
NZMN2-S33-CNA
103045
NZMN2-S40-CNA
269255
NZMN2-S50-CNA
269256
NZMN2-S63-CNA
269257
NZMN2-S80-CNA
269258
NZMN2-S100-CNA
269259
NZMN2-S125-CNA
269260
NZMN2-S160-CNA
269261
NZMN2-S200-CNA
269262
NZMN2-S250-CNA
102479
B
B
B
B
B
B
B
B
B
B
B
B
B
B
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
1 off
Circuit-breakers, switch-disconnectors
1.5
Rated current =
Rated uninterrupted current
In = I u
A
Fixed mounting
with screw terminals
Part no.
Article no.
Setting range
Short-circuit releases
Non-delayed
Ii = I n x
Std. pack
Price
See price
list
Short-circuit protection
Motor protection in conjunction with contactor and overload relay
With short-circuit release
Without overload release Ir
High switching
1.6
8- 14
capacity
2.4
8- 14
Notes
6- 11
6- 11
12
7- 12
18
5- 9
26
8- 13
33
8- 14
40
8- 14
50
8- 14
63
8- 14
80
8- 14
100
8- 14
125
8- 14
160
8- 14
200
8- 13
250
8- 10
B = box terminals
S = screw terminals
For further terminal types see accessories
Switches correspond with both UL/CSA and IEC regulations.
IEC switching performance values shown on type label.
2)
NZMH2-S1.6-CNA
269482
NZMH2-S2.4-CNA
269483
NZMH2-S5-CNA
103046
NZMH2-S8-CNA
103047
NZMH2-S12-CNA
103048
NZMH2-S18-CNA
103049
NZMH2-S26-CNA
103050
NZMH2-S33-CNA
103051
NZMH2-S40-CNA
269267
NZMH2-S50-CNA
269268
NZMH2-S63-CNA
269269
NZMH2-S80-CNA
269270
NZMH2-S100-CNA
269271
NZMH2-S125-CNA
269272
NZMH2-S160-CNA
269273
NZMH2-S200-CNA
269274
NZMH2-S250-CNA
102490
Information relevant for export to North America
1 off
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Product Standards
75
Circuit-breakers, switch-disconnectors
1.5
Rated current =
Rated
uninterrupted
current
S e ttin g r a n g e
Overload releases
In = I u
A
Ir
A
Short-circuit
releasess
Non-delayed
M o to r p o w e r
460 V
480 V
HP
Fixed mounting
with screw terminals
Part no.
Article no.
Price
See Price
list
Ii = I n x
Motor protection
100% rated
Adjustable overload releases
For use in motor circuits with contactor.
Additional motor protective characteristics (calibration) to UL508, CSA-C22.2 No. 14-05
35
High switching
capacity
100
35
100
Rated current =
Rated
uninterrupted
current
In = I u
A
90
45-90
2-14
60
140
70-140
2-14
100
200
100-200
2-14
150
90
45-90
2-14
60
140
70-140
2-14
100
200
100-200
2-14
150
Setting
range
Shortcircuit
releases
Nondelayed
Ii = In x
Fixed mounting
with screw terminals
Part no.
Article no.
Price
See price
list
Std. pack
Short-circuit protection
Motor protection in conjunction with
contactor and overload relay
With short-circuit release
Without overload release ,,
Normal
switching
capacity
76
90
2-14
140
2-14
220
2-14
NZMN2-SE90-CNA
271160
NZMN2-SE140-CNA
271161
NZMN2-SE220-CNA
271162
NZMN2-ME90-NA
118964
NZMN2-ME140-NA
118965
NZMN2-ME200-NA
118966
NZMH2-ME90-NA
118967
NZMH2-ME140-NA
118968
NZMH2-ME200-NA
118969
S
S
S
S
S
S
Notes
B=boxterminals
S=screw terminals
Forfurtherterminaltypes
see accessories
S
S
S
1 off
Product Standards
Switches
correspond with
both UL/CSA and
IEC regulations.
IEC switching
performance
values shown on
type label.
Circuit-breakers, switch-disconnectors
Circuit-breakers UL/CSA, IEC, electronic releases, 3 pole
1.5
Fixed mounting
Part no.
Article no.
Price
See Price
list
Std. pack
Notes
B = box terminals
S = screw terminals
For further terminal types see
accessories
NZMN2-ME90-BT-NA
142421
NZMN2-ME140-BT-NA
142422
NZMN2-ME200-BT-NA
142423
NZMH2-ME90-BT-NA
142424
NZMH2-ME140-BT-NA
142425
NZMH2-ME200-BT-NA
142426
1 off
Product Standards
UL CCN
NA Certification
Specially designed for NA
S
S
Suitable for
S
S
1 off
Rated current =
Rated
uninterrupted
current
In = I u
A
Setting
range
Shortcircuit
releases
Nondelayed
Ii = In x
Fixed mounting
with screw terminals
Part no.
Article no.
Price
See price
list
Std. pack
Short-circuit protection
Motor protection in conjunction with
contactor and overload relay
With short-circuit release
Without overload release ,,
Normal
switching
capacity
220
2-14
350
2-14
450
2-12
NZMN3-SE220-CNA
269341
NZMN3-SE350-CNA
269342
NZMN3-SE450-CNA
284465
Notes
B=boxterminals
S=screw terminals
Forfurtherterminaltypes
see accessories
S
S
S
1 off
Product Standards
Switches
correspond with
both UL/CSA and
IEC regulations.
IEC switching
performance
values shown on
type label.
77
Circuit-breakers, switch-disconnectors
1.5
R a te d c u r r e n t = R a te d
Setting range
SCCR 480Y/
277 V 60 Hz
SCCR 480 V
60 Hz
SCCR 600Y/
347 V 60 Hz
SCCR 600 V
60 Hz
uninterrupted current
Overload
releases
I cu
kA
I cu
kA
I cu
kA
I cu
kA
In = I u
A
Ir
A
Neutral
conductor
I r % of phase
conductor
%
Short-circuit
releases
Non-delayed
Ii = I n x
I
System and cable protection
Fixed overload releases Ir
Basic switching
apacity
Normal switching
capacity
High switching
capacity
78
25
35
25
35
125
125
100
Approx. 6 - 10
150
150
100
Approx. 6 - 10
175
175
100
Approx. 6 - 10
200
200
100
Approx. 6 - 10
225
225
100
Approx. 6 - 10
250
250
100
Approx. 6 - 10
125
125
100
Approx. 6 - 10
150
150
100
Approx. 6 - 10
175
175
100
Approx. 6 - 10
200
200
100
Approx. 6 - 10
225
225
100
Approx. 6 - 10
150
150
250
250
100
Approx. 6 - 10
100
100
125
125
100
Approx. 6 - 10
150
150
100
Approx. 6 - 10
175
175
100
Approx. 6 - 10
200
200
100
Approx. 6 - 10
225
225
100
Approx. 6 - 10
250
250
100
Approx. 6 - 10
Circuit-breakers, switch-disconnectors
Circuit-breakers UL/CSA, IEC, thermomagnetic releases , 4 pole
Fixed mounting
with box terminals
Part no.
Article no.
Price
See price
list
Std. pack
1.5
Notes
NZMB2-4-AF125-BT-NA
113011
NZMB2-4-AF150-BT-NA
113012
NZMB2-4-AF175-BT-NA
113013
NZMB2-4-AF200-BT-NA
113014
NZMB2-4-AF225-BT-NA
113015
NZMB2-4-AF250-BT-NA
113016
NZMN2-4-AF125-BT-NA
113005
NZMN2-4-AF150-BT-NA
113006
NZMN2-4-AF175-BT-NA
113007
NZMN2-4-AF200-BT-NA
113008
NZMN2-4-AF225-BT-NA
113009
NZMN2-4-AF250-BT-NA
113010
NZMH2-4-AF125-BT-NA
113017
NZMH2-4-AF150-BT-NA
113018
NZMH2-4-AF175-BT-NA
113019
NZMH2-4-AF200-BT-NA
113020
NZMH2-4-AF225-BT-NA
113021
NZMH2-4-AF250-BT-NA
113022
1 off
B
B
B
B
B
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Current Limiting CB
Max. Voltage Rating
Degree of Protection
B = box terminals
S = screw terminals
For further terminal types see
accessories
Switches correspond with both
UL/CSA and IEC regulations. IEC
switching performance values shown
on type label.
1 off
B
B
B
B
B
1 off
B
B
B
B
B
79
1.5
Circuit-breakers, switch-disconnectors
Molded case switches for North America
NS...NA
1
Rated current = Rated
uninterrupted current
SCCR
600Y/
347 V
60 Hz
SCCR
600 V
60 Hz
Response
value of
short-circuit
releases
I cu
kA
I cu
kA
Ii
A
1250
100
1250
125
1250
50
2500
In = I u
A
S w itc h in g c a p a c ity
SCCR
SCCR
480Y/
480 V
277 V
60 Hz
60 Hz
I cu
I cu
kA
kA
Fixed mounting
with screw terminals
Part no.
Price
Article no.
See price
list
160
35
100
100
200
2500
250
2500
400
100
100
50
50
600
800
80
6600
6600
65
65
42
42
1000
25000
1200
25000
Screw
terminals as
accessories
NS2-160-NA
102684
NS2-200-NA
102685
NS2-250-NA
102686
NS3-400-NA
102687
NS3-600-NA
102688
NS4-800-NA
102689
NS4-1000-NA
102690
NS4-1200-NA
102691
S
S
S
S
Circuit-breakers, switch-disconnectors
Molded case switches for North America
Fixed mounting
with box terminals
Part no.
Article no.
1
Price
See price
list
Std. pack
NS1-63-NA
102681
NS1-100-NA
102682
NS1-125-NA
102683
NS2-160-BT-NA
107578
NS2-200-BT-NA
107579
NS2-250-BT-NA
107610
Terminals as
accessory
1.5
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Max. Voltage Rating
Degree of Protection
B
B
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Max. Voltage Rating
Degree of Protection
B
B
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
Max. Voltage Rating
Degree of Protection
Notes
B = box terminals
S = screw terminals
For further terminal types
see accessories
IEC/EN 60947-2: circuit-breaker without
overcurrent protection (CBI-X) with main switch
characteristics and isolating characteristics to
IEC/EN 60204
81
Circuit-breakers, switch-disconnectors
1.6
Terminals
NZM1
HPL17082EN
1
Max. cable
connection area
Number of
poles
F o r u s e w ith
T e r m in a l c a p a c ity
Cable
Cable lugs
T e r m in a l c a p a c ity
Terminal
capacity
Copper strip
No. of discs
width disc
thickness
mm
Copper bar
width x
thickness
1 x 12 - 2/0
2 x 9 x 0.8
1 x 12 - 2/0
2 x 9 x 0.8
1 x 12 - 2/0
12 x 5
1 x 12 - 2/0
12 x 5
1 x 6 - 3/0
1 x 6 - 3/0
min. 12 x 5
AWG/kcmil
mm
Box terminal
Standard
equipment
10
3 pole
NZM1,
PN1,
Copper cable
1 x 10 - 70
2 x 6 - 25
N(S)1
1)
NZM1-4,
PN1-4,
N1-4
1 x 10 - 70
2 x 6 - 25
mm
12
4 pole
3 pole
Screw terminals
Copper cable
lugs
Aluminium cable
lugs
o 6.5
NZM1,
PN1,
N(S)1
1)
1 x 10 - 70
2 x 6 - 25
1 x 10 - 35
2 x 10 - 35
1)
16
4 pole
NZM1-4,
PN1-4,
N1-4
3 pole
NZM1,
PN1,
N(S)1
Copper
cable
Aluminium
cable
4 pole
PN1-4,
N1-4
NZM1-4,
NZM1,
PN1,
Copper cable
lugs
1 x 10 - 70
2 x 6 - 25
1 x 10 - 35
2 x 10 - 35
1)
Tunnel terminal
14.5
4 pole
3 pole
4 pole
N1
NZM1-4,
PN1-4,
N1-4
1 x 16 - 95
1)
1 x 16 - 95
1)
1 x 10-70
2 x 6-25
1 x 10-35
2 x 10-35
1)
Aluminium cable
lugs
1 x 10-70
2 x 6-25
1 x 10-35
2 x 10-35
1)
Notes
82
1)
max. 16 x 5
min. 12 x 5
max. 16 x 5
Circuit-breakers, switch-disconnectors
Terminals
1.6
HPL17083EN
Part no.
Article no.
when ordered
separately
NZM1-XKC
260015
Price
See price
list
Std. pack
Notes
I n fo r m a ti o n r e l e v a n t fo r e x p o r t to N o r th A m e r i c a
1 set
Product Standards
Product Standards
Product Standards
NZM1-4-XKC
267075
1 set
NZM1-XKS
260019
1 set
NZM1-4-XKS
266725
1 set
NZM1-XKA
266730
1 set
NZM1-4-XKA
266731
NZM1-XKR
266734
1 set
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Suitable for
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Suitable for
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Suitable for
NZM1-4-XKR
266737
83
Circuit-breakers, switch-disconnectors
1.6
Terminals
NZM1
Max. cable connection
area
Number of
poles
Control cable
terminals
Cover
Phase isolators
84
Terminal capacity1)
mm
AWG/kcmil
3 a n d 4 p o le
N Z M 1( - 4) , P N 1( - 4) , N ( S ) 1( - 4)
S c r e w te r m in a ls
1 x 0.75- 2.5
2 x 0.75-1.5
1 x 18-14
2 x 18-16
3 a n d 4 p o le
N Z M 1( - 4) , P N 1( - 4) , N ( S ) 1( - 4)
B o x te r m in a l
1 x 0.75- 2.5
2 x 0.75-1.5
1 x 18-14
2 x 18-16
3 p o le
N Z M 1, P N 1, N 1
4 p o le
N Z M 1- 4, P N 1- 4, N 1- 4
3 p o le
N Z M 1, P N 1, N ( S ) 1
4 p o le
N Z M 1- 4, P N 1- 4, N 1- 4
3 p o le
N Z M 1, P N 1, N 1
N Z M 1- 4, P N 1- 4, N 1- 4
3 p o le
N Z M 1, P N 1, N S 1
4 p o le
N Z M 1- 4, P N 1- 4, N 1- 4
3 p o le
N Z M 1, P N 1, N ( S ) 1
4 p o le
N Z M 1- 4, P N 1- 4, N 1- 4
4 p o le
1.6
Circuit-breakers, switch-disconnectors
Terminals
HPL17085EN
Part no.
Article no.
when ordered
separately
NZM1-XSTS
260150
NZM-XSTK
266739
Price
See price
list
Std. pack
Notes
1 off
Containsfortwoterminallocationslocated attop
or bottom for 3 or 4 pole circuit-breakers.
Included as standard with tunnel terminal.
Degree of protection IP1X
Height orthickness of connections: 2 mm
ProductStandards
1 off
NZM1-XKSFA
100780
NZM1-4-XKSFA
100781
1 off
NZM1-XKSA
260021
1 off
1 off
Containsfortwoterminallocationslocated attop
or bottom for 3 or 4 pole circuit-breakers.
Included as standard with tunnel terminal.
Degree of protection IP1X
Height orthickness of connections: 2 mm
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Suitable for
ProductStandards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Suitable for
NZM1-4-XKSA
266741
1 off
NZM1-XIPK
266744
NZM1-4-XIPK
266745
1 set
NZM1-XIPA
266748
NZM1-4-XIPA
266749
1 set
NZM1-XKP
119862
1 set
NZM1-4-XKP
119863
1 set
1 set
1 set
UL489; CSA-C22.2
No. 5-09; IEC60947,
CE marking
E140305
DIHS
022086
1437-01
UL Listed,
CSA certified
Refer to main component information
UL489; CSA-C22.2
No. 5-09; IEC60947,
CE marking
E140305
DIHS
022086
1437-01
UL Listed,
CSA certified
Refer to main component information
85
Circuit-breakers, switch-disconnectors
1.6
Terminals
NZM2
1
Max. cable
connection area
Number
of poles
Terminal capacity
Cable
Cable lugs
Terminal capacity
Terminal
capacity1)
AWG/kcmil
mm
Box terminal
3 pole
Copper bar
width x
thickness
mm
Copper cable
1 x 10-185
2 x 4-70
1 x 12 - 350
2 x 9 x 0.8
Copper cable
lugs
1 x 10 - 185
2 x 4 - 70
1 x 10 - 50
2 x 10 - 50
1 x 12 - 350
2 x 16 x 0.8
16 x 5
15
Copper strip
No. of discs
width disc
thickness
mm
18
Screw terminals
Standard
equipment
NZM2-4, PN2-4,
N2-4
160 A
NZM2-4, PN2-4,
N2-4
> 160 A
3 pole
Aluminium cable
lugs
o 8.5
4 pole
24
Tunnel terminal
4 pole
NZM2-4, PN2-4,
N2-4
3 pole
4 pole
NZM2-4, PN2-4,
N2-4
Copper cable
Aluminium cable
20.5
Rear terminal
bolts
3 pole
NZM2, PN2, N2
Copper cable
lugs
Aluminium cable
lugs
86
1 x 6 - 350
1 x 10 - 185
2 x 4 - 70
1 x 10 - 50
2 x 10 - 50
NZM2-4, PN2-4,
N2-4
4 pole
Notes
1 x 16 - 185
1 x 16 - 185
Up to 240 mm
can be
connected
depending on
the cable
manufacturer.
1)
2 x 16 x 0.8
6 x 24 x 0.5
16 x 5
20 x 5
Circuit-breakers, switch-disconnectors
Terminals
1.6
HPL17087EN
Price
See price
list
Part no.
Article no.
when ordered
separately
Price
See price
list
Std. pack
Notes
NZM2-160-XKC
262240
1 set
NZM2-250-XKC
262244
1 set
1 set
1 set
Ue525 V AC:
+NZM2-4-160-XKCO
266751
+NZM2-4-160-XKCU
266753
+NZM2-4-250-XKCO
266752
+NZM2-4-250-XKCU
266754
+NZM2-XKRO
266763
+NZM2-XKRU
266764
+NZM2-4-XKRO
266766
+NZM2-4-XKRU
266767
NZM2-4-160-XKC
266755
1 set
NZM2-4-250-XKC
266756
1 set
NZM2-XKS
260030
1 set
NZM2-4-XKS
266750
1 set
NZM2-XKA
271457
1 set
NZM2-4-XKA
271458
1 set
NZM2-XKR
266765
1 set
NZM2-4-XKR
266768
1 set
1 set
1 set
1 set
1 set
87
Circuit-breakers, switch-disconnectors
1.6
Terminals
NZM2
1
Number of
poles
Control cable
terminals
Cover
Phase isolators
Terminal covers,
knockout
Terminal capacity
Connection
Terminal
capacity1)
mm
AWG/kcmil
3 and 4 pole
Screw terminals
1 x 0.75 - 2.5
2 x 0.75 - 1.5
1 x 18 - 14
2 x 18 - 16
3 and 4 pole
Box terminal
1 x 0.75 - 2.5
2 x 0.75 - 1.5
1 x 18 - 14
2 x 18 - 16
3 pole
1 x 10-185
2 x 4-70
1 x 10-50
2 x 10-50
4 pole
Copper cable
lugs
Aluminium cable
lugs
3 pole
4 pole
3 pole
4 pole
3 pole
+NZM2-XKSFAO
108269
+NZM2-XKSFAU
108270
+NZM2-4-XKSFAO
108271
+NZM2-4-XKSFAU
108272
4 pole
4 pole
3 pole
4 pole
88
150 mm2
120 mm2
95 mm2
185 mm2
Price
See price
list
Circuit-breakers, switch-disconnectors
Terminals
Part no.
Article no.
when ordered
separately
Price
See price
list
Std. pack
NZM2-XSTS
260156
1 set
NZM-XSTK
266739
1 set
NZM2-XKSAE
119868
NZM2-4-XKSAE
119870
1 set
NZM2-XKSA
260038
1 off
NZM2-4-XKSA
266770
1 o ff
NZM2-XKP
119864
NZM2-4-XKP
119865
1 set
NZM2-XKSFA
104640
1 set
1 set
1 off
1 off
NZM2-4-XKSFA
104641
NZM2-XIPK
266773
NZM2-4-XIPK
266774
1 set
1 set
NZM2-XIPA
266777
NZM2-4-XIPA
266778
1 set
KS150-NZM7
059777
KS120-NZM7
059776
KS95-NZM7
059775
NZM2-XKS185
260032
3 off
1 set
1.6
1
Notes
CE marking
E140305
DIHS
022086
1437-01
UL Listed, CSA certified
Refer to main component information
CE marking
E140305
DIHS
022086
1437-01
UL Listed, CSA certified
Refer to main component information
89
Circuit-breakers, switch-disconnectors
1.6
Terminals
1 NZM3
HPL17090EN
Max. cable
connection area
Number
of poles
Rated
current1)
In
Terminal capacity
Cable
Cable lugs
Terminal
capacities1)
Terminal ca pa city
AWG/kcmil
mm
Copper strip
No. of discs
width disc
thickness
mm
Copper bar
width x
thickness
min. 6 x 16 x 0.8
max. 10 x 24 x 1.0
or
max. 11 x 21 x 1
10 x 24 x 1.0
+ 5 x 24 x 1.0
or
(2 x) 8 x 24 x 1.0
10 x 32 x 1.0
+ 5 x 32 x 1.0
30 x 10
+ 30 x 5
mm
Box terminal
16
3 pole
NZM3(-4),
PN3(-4),
N(S)3(-4)
max. 500
400 UL/
CSA
Copper cable
Copper cable
1 x 35 - 240
2 x 16 - 120
1 x 2 - 350
630
Copper cable
1 x 35 - 240
2 x 16 - 120
1 x 2 - 350
630
Copper cable
lugs
1 x 16 - 300
2 x 16 - 240
1 x 4 - 350
2 x 350
1 x 10 - 120
2 x 10 - 120
1 x 4 - 350
2 x 350
2 x 300
2 x 500
(2 x) 10 x 50 x 1.0
NZM3XKV70-2:
4 x 35 - 185
NZM3XKV70-2 +
NZM4-XKA:
4 x 50 - 240
NZM3XKV70-2:
2 x 350
NZM3XKV70-2 +
NZM4XKA:
4 x 500
NZM3-XKV70-2 +
NZM4-XKB:
6 x 16 - 0.8
(2 x) 10 x 32 x 1
25
4 pole
3 pole
NZM3,
PN3,
N(S)3
Max. 400
o 10.5
Aluminium cable
lugs
32
4 pole
NZM3-4,
PN3-4,
N(S)3-4
3 pole
NZM3,
PN3,
N(S)3
Copper cable
lugs
(2 x) 10 x 50
Aluminium cable
lugs
4 pole
NZM3-4,
PN3-4,
N3-4
3 pole
NZM3,PN3,
N(S)3
4 pole
NZM3-4,
PN3-4,
N3-4
3 pole
NZM3, PN3,
N(S)3
630
Copper cable
lugs
630
Copper cable
lugs
(2 x) 10 x 50
90
2 x 95-300
2 x 500
(2x) 10 x 32 x 1.0
(2 x) 10 x 40
Circuit-breakers, switch-disconnectors
Terminals
1.6
NZM3
Part no. suffix
Article no. for
ordering with
basic device
+NZM3-XKCO
262246
+NZM3-XKCU
262245
HPL17091EN
Price
See price
list
separately
NZM3-XKC
260042
+NZM3-4-XKCO
266781
+NZM3-4-XKCU
266782
Part no.
Article no.
Price
See price
list
Std. pack
N o te s
1 set
Product Standards
Product Standards
Product Standards
NZM3-4-XKC
266783
1 set
NZM3-XKS
260039
1 set
NZM3-4-XKS
266780
1 set
NZM3-XKV70
100514
1 set
NZM3-4-XKV70
100515
1 set
NZM3-XKV70-2
119860
1 set
NZM3-4-XKV70-2
132673
1 set
NZM3-XKV70KB
112884
1 set
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Suitable for
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Suitable for
UL489; CSA-C22.2
No. 5-09; IEC60947,
CE marking
E31593
DIHS
022086
1437-01
UL Listed,
CSA certified
Refer to main componentinformation
UL489; CSA-C22.2
No. 5-09; IEC60947,
CE marking
E31593
DIHS
022086
1437-01
UL Listed,
CSA certified
Refer to main componentinformation
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
UL489; CSA-C22.2
No. 5-09; IEC60947,
CE marking
E140305
DIHS
022086
1432-01
UL Listed,
CSA certified
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
UL489; CSA-C22.2
No. 5-09; IEC60947,
CE marking
E140305
DIHS
022086
1432-01
UL Listed,
CSA certified
91
Circuit-breakers, switch-disconnectors
1.6
1
Terminals
NZM3
Max. cable
connection area
Number
of poles
Rated
current1)
In
T e r m in a l c a p a c ity
Cable
Cable lugs
T e r m in a l c a p a c ity
Terminal
capacities1)
AWG/kcmil
mm
Copper strip
No. of discs
width disc
thickness
m
Copper bar
width x
thickness
(2 ) 11 x 21 x 1.0
min. 6 x 16 x 0.8
max. 10 x 32 x 1.0
min. 20 x 5
max. 30 10
Max. 500
Copper cable
NZM3, PN3,
N(S)3
NZM3-4,
PN3-4, N3-4
630
NZM3,
PN3, N(S)3
NZM3-4,
PN3-4,
N3-4
Max. 350
Copper
cable
Aluminium
cable
1 x 16 - 185
1 x 6 - 350
3 pole
NZM3,
PN3,
N(S)3
Max. 630
Copper
cable
Aluminium
cable
1 x 50-240
2 x 50-240
1 x 0-500
2 x 0-500
4 pole
NZM3-4,
PN3-4, N3-4
3 pole
NZM3,
PN3,
N3
Max. 630
Copper cable
lugs
1 x 16-240
2 x 16-240
4 pole
NZM3-4,
PN3-4,
N3-4
Max. 500
Aluminium cable
lugs
3 and 4
pole
NZM3,
PN3,
N(S)3
Screw terminals
1 x 0.75-2.5
2 x 0.75-1.5
1 x 18-14
2 x 18-16
3 and 4
pole
NZM3-4,
PN3,
N(S)3-4
Box terminal
1 x 0.75-2.5
2 x 0.75-1.5
1 x 18-14
2 x 18-16
3 pole
4 pole
1 x 120 - 300
Tunnel terminal
3 pole
4 pole
20.5
22.5
1 x 10-120
2 x 10-120
Notes
92
1)
The rated operational current values have been determined according to IEC/EN 60947 (switchgear standard). They
generally relate to the max. defined cross-sections and are intended as a general guide.
The engineering standards which apply in each case must be observed.
Circuit-breakers, switch-disconnectors
Terminals
1.6
NZM3
Part no. suffix
Article no. for
ordering with
basic device
Price
See price
list
Part no.
Article no.
when ordered
separately
NZM3-XK300
100782
Price
See price
list
Std. pack
Notes
1 set
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Suitable for
NZM3-4-XK300
100783
1 set
NZM3-XK22X21
100784
NZM3-4-XK22X21
100785
1 set
NZM3-XKA12)
271459
NZM3-4-XKA12)
271460
1 set
NZM3-XKA2
271461
1 set
NZM3-4-XKA2
271462
1 set
+NZM3-XKRO
266790
+NZM3-XKRU
266791
+NZM3-4-XKRO
266793
+NZM3-4-XKRU
266794
NZM3-XKR
266792
1 set
NZM3-4-XKR
266795
1 set
UL489; CSA-C22.2
No. 5-09; IEC60947,
CE marking
E31593
DIHS
022086
1432-01
UL Listed,
CSA certified
Refer to main componentinformation
1 set
1 set
1 set
1 set
NZM3/4-XSTS
266797
1 set
NZM-XSTK
266739
1 set
93
Circuit-breakers, switch-disconnectors
1.6
1
Terminals
NZM3
Max. cable
connection area
Number
of poles
Part no.
Article no. when
ordered separately
Price
See price
list
Std. pack
3 pole
NZM3-XKSAE
119869
1 set
4 pole
NZM3-4-XKSAE
119871
1 set
3 pole
NZM3-XKSA
260045
1 off
4 pole
NZM3-4-XKSA
266801
1 off
3 pole
NZM3-XKP
100512
1 set
4 pole
NZM3-4-XKP
100513
1 set
3 pole
NZM3-XKSFA
104642
1 off
4 pole
NZM3-4-XKSFA
104643
1 off
3 pole
NZM3, PN3, N3
+ NZM3-XKV70(-2)
NZM3-4, PN3-4, N3-4
+ NZM3-4-XKV70
NZM3-XKSAV
119858
NZM3-4-XKSAV
132675
1 off
NZM3-XIPK
266804
NZM3-4-XIPK
266805
1 set
NZM3-XIPA
266808
NZM3-4-XIPA
266809
1 set
NZM3-XKS185
260040
NZM3-XKS240
260041
3 off
Cover
Phase isolators
4 pole
1 off
3 pole
NZM3, PN3, N3
4 pole
3 pole
4 pole
1 set
1 set
94
3and4
pole
NZM3(-4),
PN3(-4), N(S)3(-4)
3 off
Circuit-breakers, switch-disconnectors
Terminals
1.6
NZM3
Notes
Contains parts for a terminal located at top or bottom for 3 or 4 pole switches.
.
Contact protection where cable lugs are used on screw terminals
When using insulated conductor material, degree of protection IP2X.
Contains parts for a terminal located at top or bottom for 3 or 4 pole switches.
Insulation/protection against direct contact where cable lugs, bars or tunnel terminals are used.
Included in set with tunnel terminals.
When using insulated conductor material to degree of protection IP1X.
Product Standards
Contains parts, including insulating plate for mounting plate, for a terminal located at top or bottom for
3 or 4 pole circuit-breakers.
Included with the connection width extension.
Cannot be combined with the NZM3(-4)-XKA tunnel terminal, NZM3(-4)-XKR connection on rear.
Insulation protection where cable lugs, bars, or flat conductor are used.
Product Standards
Contains parts for a terminal located at top or bottom for 3 or 4 pole switches.
Enhanced contact protection (simplified finger protection).
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Suitable for
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Suitable for
Contains parts for a terminal located at top or bottom for 3 pole circuit-breakers.
Insulation protection/protection against direct contact for connection of cable lugs or bars to connection
width extension.
Can also be used fir connection width extension NZM3-XKV70 with terminals NZM3-XK300, NZM3-XK22x21
or NZM4-XKA.
When using insulated conductor material, degree of protection IP2X.
Contains parts for a terminal located at top or bottom for 3 or 4 pole circuit-breakers.
Enhanced contact protection to IP2X.
Protection when reaching into the cable connection area with the connection of cables in the box terminal.
with 2 conductors max. cross section 70 mm 2.
Cannot be combined with NZM-XSTK control circuit terminal.
Contains parts for a terminal located at top or bottom for 3 or 4 pole switches.
Enhanced contact protection to IP2X.
When fitting to NZM3...-(C)NA or N3...-NA:
with 2 conductors max. cross section 70 mm2.
95
Circuit-breakers, switch-disconnectors
1.6
Terminals
1 NZM4
HPL17096EN
Space requirement
Rated
current 1)
Number
of poles
For use
with
T e r m in a l c a p a c ity
Cable
Cable
lugs
Terminal
capacity
T e r m in a l c a p a c ity
AWG/kcmil
In
A
mm
Copper strip
No. of discs
width disc
thickness
mm
Copper bar
width x
thickness
mm
Screw terminals
2- h o le
20
Threaded stud
standard
equipment
o 10.5
Screws
Max.
1600
3 and 4
pole
NZM4(-4)
N4(-4)
N(S)4
NZM4,
N(S)4
NZM4-4,
N4-4
Copper
cable lugs
1 x 120-185
4 x 50-185
1 x 250-350
4 x 0-350
(2 x)
10 x 50 x 1.0
(2 x) 50 x 10
3 pole
NZM4,
N(S)4
Copper
cable lugs
1 x 120-300
2 x 95-300
1 x 250-600
2 x 000-600
(2 x)
10 x 40 x 1.0
(2 x)
10 x 50 x 1.0
(2 x) 40 x 10
(2 x) 50 x 10
4 pole
NZM4-4,
N4-4
3 pole
NZM4,
N(S)4
2 x 95-185
4 x 35-185
2 x 000-350
4 x 2-350
(2 x)
10 x 50 x 1.0
(2 x) 50 x 10
4 pole
NZM4-4,
N4-4
NZM4,
N(S)4
2 x 95-300
2 x 000-600
(2 x)
10 x 40 x 1.0
(2 x)x 50 x 1.0
10
(2 x) 40 x 10
(2 x) 50 x 10
3 pole
o 10.5
25
4 pole
50
Module plate
1- h o le
2- h o le
2- h o le
Max.
1250
Max.
1400
Max.
1250
3 pole
4 pole
Max.
1600
3 pole
4 pole
96
NZM4-4,
N4-4
NZM4,
N(S)4
NZM4-4,
N4-4
Copper
cable lugs
Circuit-breakers, switch-disconnectors
Terminals
1.6
NZM4
Part no.
Article no. when
ordered separately
Price
See price
list
Std. pack
NZM4-XKS
127736
NZM4-4-XKS
127737
1 set
NZM4-XKM1
266814
1 set
NZM4-4-XKM1
266815
NZM4-XKM2
266820
Notes
1 set
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Suitable for
1 set
1 set
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Suitable for
NZM4-4-XKM2
266821
NZM4-XKM2S-1250
284471
NZM4-4-XKM2S-1250
284472
NZM4-XKM2S-1600
284473
1 set
1 set
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Suitable for
1 set
1 set
Product Standards
1 set
UL489; CSA-C22.2
No. 5-09; IEC60947,
CE marking
E31593
DIHS
22086
1432-01
UL Listed, CSA certified
Refer to main component
information
UL489; CSA-C22.2
No. 5-09; IEC60947,
CE marking
E31593
DIHS
22086
1432-01
UL Listed, CSA certified
Refer to main component
information
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Suitable for
NZM4-4-XKM2S-1600
284474
UL489; CSA-C22.2
No. 5-09; IEC60947,
CE marking
E31593
DIHS
22086
1432-01
UL Listed, CSA certified
Refer to main component
information
UL489; CSA-C22.2
No. 5-09; IEC60947,
CE marking
E31593
DIHS
22086
1432-01
UL Listed, CSA certified
Refer to main component
information
97
Circuit-breakers, switch-disconnectors
1.6
Terminals
1 NZM4
Rated current 1)
In
Number
of poles
F o r u s e w ith
T e r m in a l c a p a c ity
Cable
Terminal
Cable lugs
capacity
AWG/kcmil
mm
T e r m in a l c a p a c ity
Copper strip
No. of discs width
disc thickness
mm
Copper bar
width x
thickness
mm
3 pole
NZM4, N(S)4
4 pole
NZM4-4, N4-4
3 pole
NZM4, N(S)4
Copper
cable
Aluminium
cable
1 x 50-240
4 x 50-240
1 x 0-500
4 x 0-500
4 p o le
N Z M 4- 4, N 4- 4
3 pole
NZM4, N4
min. 6 x 16 x 0.8
max. (2 x) 10 x 32 x 1.0
min. 6 x 16 x 0.8
max. (2 x) 10 x 32 x 1.0
Tunnel terminal
Max. 1100
22.5
Max. 1250
Copper cable
lugs
4 pole
NZM4(-4), N4(-4)
Aluminium
cable lugs
Notes
98
1)
1 x 120-185
2 x 95-185
4 x 35-185
1 x 185
2 x 70-185
4 x 50-185
The rated operationa l current values have been determ ined according to IEC/EN 60947 (switc
relate to the max. defined cross-sections and are intended as a general guide.
The engineering standards which apply in each case must be observed.
(2 x) 10 x 50 x 1.0
(2 x) 50 x 10
Circuit-breakers, switch-disconnectors
Terminals
1.6
NZM4
Part no.
Article no. when
ordered separately
Price
See price
list
Std. pack
N o te s
I n fo r m a ti o n r e l e v a n t fo r e x p o r t to N o r th A m e r i c a
NZM4-XKB
266829
1 set
NZM4-4-XKB
266831
1 set
NZM4-XKA
266836
1 set
NZM4-4-XKA
266837
1 set
NZM4-XKR
266842
NZM4-4-XKR
266843
1 set
1 set
99
1.6
Circuit-breakers, switch-disconnectors
Terminals
1 NZM4
Space requirement
Rated
current1)
Number
of poles
For use
with
T e r m in a l c a p a c ity
Cable
Cable
lugs
Terminal
capacity
T e r m in a l c a p a c ity
AWG/kcmil
In
mm
Copper strip
No. of discs
width disc
thickness
mm
Copper bar
width x
thickness
mm
Max.
1600
3 pole
NZM4,
N(S)4
Max.
1600
4 pole
NZM4-4,
N4-4
1600
3 p o le
N Z M 4,
N(S)4
Copper
cable lugs
4 x 300
6 x 95-240
4 x 600
6 x 000-500
max. (2 x)
10 x 80 x 1.0
max. (2 x)
80 x 10
Copper
cable lugs
4 x 95-300
4 x 500
(2x)
10 x 80 x 1.0
(2 x) 10 x 80
o 10.5
o 10.5
25
50
20
o 10.5
o 10.5
25
50
Notes
100
1)
The rated operational current values have been determined according to IEC/EN 60947 (switchgear standard). They generally
relate to the max. defined cross-sections and are intended as a general guide.
The engineering standards which apply in each case must be observed.
Circuit-breakers, switch-disconnectors
Terminals
1.6
NZM4
Part no.
Article no. when
ordered separately
NZM4-XKV95
281591
1
Price
See price
list
Std. pack
Notes
1 set
Product Standards
NZM4-XKV110
281593
NZM4-4-XKV95
281592
1 set
NZM4-4-XKV120
281594
NZM4-XKV95-2KB
119861
1 set
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Suitable for
101
Circuit-breakers, switch-disconnectors
1.6
Terminals
NZM4
Number of poles
Terminal capacity
Connection
Terminal capacity
mm
AWG/kcmil
1 x 0.75-2.5
2 x 0.75-1.5
1 x 18-14
2 x 18-16
NZM3(-4),
PN3,
N(S)3(-4)
3 pole
NZM4,
N(S)4
NZM4-4,
N4-4
Screw terminals
Cover
4 pole
Cover size
For connection width extension
3 pole
NZM4, N(S)4
+ NZM4-XKV95(KB)
3 pole
NZM4, N(S)4
+ NZM4-XKV
4 pole
NZM4(-4), N(S)4(-4)
+ NZM4-4-XKV
3 pole
NZM4,
N(S)4
NZM4-4,
N4-4
Insulation plate
4 pole
Phase isolators
3 pole
NZM4
N(S)4
4 pole
NZM4-4, N4-4
Cable lug
Not UL/CSA approved
When using cable lugs without NZM3(-4)-XKSA cover, they must be insulated.
3 and 4 pole
NZM41-41, NIS141-4)
185 m m2
240 mm 2
102
Circuit-breakers, switch-disconnectors
Terminals
1.6
NZM4
Part no.
Article no. when
Price
See price
list
Std. pack
Notes
NZM3/4-XSTS
266797
1 off
NZM4-XKSA
266846
1 off
NZM4-4-XKSA
266847
1 off
NZM4-XKSAV
119876
1 off
NZM4-XISP
119866
1 off
NZM4-4-XISP
119867
1 off
NZM4-XKSFA
292193
1 off
NZM4-4-XKSFA
292194
1 off
NZM4-XKP
281595
1 set
NZM4-4-XKP
281596
1 set
NZM3-XKS185
260040
NZM3-XKS240
260041
3 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Suitable for
103
Circuit-breakers, switch-disconnectors
1.6
Terminals
NZM4
Rated current
Std.
pack
Notes
N4-XAS12-1000
285609
1 set
N4-XAS12-1250
285610
1 set
Part no.
Article no. when
ordered separately
Price
See price
list
In
A
Adapter set N(ZM)4/N(ZM)12
Not UL/CSA approved
Max. 1000
N4
3 pole
Max. 1250
104
N4
3 pole
Max. 1600
N4
3 pole
N4-XAS12-1600
285611
1 set
Max. 1000
NZM4
3 pole
NZM4-XAS12-1000
285612
1 set
Max. 1250
NZM4
3 pole
NZM4-XAS12-1250
285613
1 set
Max. 1600
NZM4
3 pole
NZM4-XAS12-1600
285614
1 set
Max. 1250
NZM4, N4
3 pole
NZM4-XAS14-1250
283291
1 set
1600
NZM4, N4
3 pole
NZM4-XAS14-1600
283292
1 set
Circuit-breakers, switch-disconnectors
Plug-in units, withdrawable units
1.6
Number of poles
Part no.
Article no.
Price
See Price
List
Std.
pack
Notes
B = box terminals
S = screw terminals
For further terminal types
see accessories
Plug-in units
For circuit-breakers NZM and switch-disconnectors N
Not UL/CSA approved
Not for U e > 690 V
Plug-in socket
Completion
NZM1
through switches
N1
with plug-in
insert
NZM...-SVE...
NZM2
N2
NZM2-4
N2-4
NZM1, N1
NZM2(-4)
N2(-4)
Number
of poles
NZM1-XSVS
109777
1 off
Inmax. at:
20C: 125 A (NZM1)
70C: 100 A (NZM1)
Mounting position: vertical, 90 right, 90 left
Order control circuit plug unit separately!
3 pole
NZM2-XSVS
266699
NZM2-4-XSVS
266700
1 off
1 off
Inmax. at:
20C: 250 A
40C: 230 A (NZM2-)
250 A (NZM2-E)
Mounting position: vertical, 90 right, 90 left
Order control circuit plug unit separately!
NZM2-XSVHI
266705
1 off
10 terminals
NZM2-XSVR
266706
1 off
4 pole
For auxiliary
contact,
shunt/overvoltage release
For remote
operator
NZM2(-4)
N2(-4)
For use
with
3 pole
Price
See Price
List
Std.
pack
Part no.
Article no. for
separate order
Price
See Price
List
Std.
pack
Notes
1 off
1 off
1 off
Inmax. at:
20 C: 605 A (NZM3), 1600 A (NZM4)
40 C: 550 A (NZM3), 1500 A (NZM4)
Mounting position:
NZM3: vertical, 90 left
NZM4: vertica
1 off
Withdrawable unit
For circuit-breakers NZM and switchdisconnectors N
Not UL/CSA approved
Not for Ue > 690 V
Socket base
For switches with withdrawable carrier.
Also for reserved compartments.
NZM3
3 pole
N3
NZM3-4
4 pole
N3-4
NZM4
3 pole
N4
NZM4-4
4 pole
N4-4
Withdrawable carrier
Suitable for socket base
Only in combination with switch
NZM4
N4
NZM4-4
N4-4
3 pole
4 pole
NZM3-XAVS
266711
NZM3-4-XAVS
266712
NZM4-XAVS
266713
NZM4-4-XAVS
266714
+NZM4-XAVE
266717
+NZM4-4-XAVE
266718
1 off
1 off
3 positions:l
Connected, test, disconnected
Position indication is mechanical
with pointers.
Additional electrical indication with
auxiliary contacts possible.
One N/O or NC contact M22-(C)K01
or M22-(C)K10 each per position.
Alternatively also double contacts
M22-CK...
Complete with control circuit plug
unit.
All auxiliary contact (HIA, HIN, HIV)
and shunt release connections to
the control circuit plug unit are
already present.
Maximum configuration: 3 contacts
HIN, 2 contacts HIA, 2 contacts HIV
Cannot be combined with adapter set
NZM4/NZM14 (NZM4-XSAS14-...) or
N(ZM)4/N(ZM)12.
105
Circuit-breakers, switch-disconnectors
1.6
1
NZM1, M22-...
For use with
Contact configuration:
Contact
sequences
opening according to
IEC/EN 60947-5-1
N/O = normally
NC = normally
closed contact
open contact
Part no.
Article no.
when ordered
separately
Price
See price
list
Std. pack
Auxiliary contacts
Standard auxiliary contacts (HIN)1)
Switches with the main contacts. Used for indicating and interlocking tasks.
Single contact
NZM1(-4), 2(-4), 3(-4), 4(-4)
PN1(-4), 2(-4), 3(-4)
N(S)1(-4), 2(-4), 3(-4), 4(-4)
1.X3
1 N/O
1.X4
1 NC
1.X1
1.X2
Double contact
1 N/O
1 NC
2 NC
2 N/O
Early-make auxiliary contact2)
For interlocking and load shedding circuits, as well as for early make of the undervoltage
release in main switch/emergency switching off applications
With clamp
NZM1(-4)
2 N/O
terminal on left
PN1(-4)
switch side.
N(S)1(-4)
With clamp
terminal on
right switch
side.
2 N/O
With 3 m
connection
cable instead
of screw
connection.
2 N/O
1.X3
1.X1
1.X4
1.X2
1.X1
1.X1
1.X2
1.X2
1.X3
1.X3
1.X4
1.X4
3.13 3.23
M22-K10
216376
M22-K01
216378
20 off
NZM1-XHIV
259426
1 off
3.14 3.24
3.13 3.23
NZM1-XHIVR
292195
3.14 3.24
3.13 3.23
NZM1-XHIVL
259432
3.14 3.24
NZM2(-4), 3(-4)
PN2(-4), 3(-4)
N(S)2(-4), 3(-4)
NZM4(-4)
N(S)4(-4)
2 N/O
2 N/O
3.13 3.23
NZM2/3-XHIV
259430
3.14 3.24
3.13 3.23
NZM4-XHIV
266172
3.14 3.24
1)
1 NC
1.X3
1.X4
1.X1
1.X2
Double contact
1 N/O
1 NC
2 NC
2 N/O
1)
Product Standards
UL File No.
UL CCN
106
1.X3
1.X1
1.X4
1.X2
1.X1
1.X1
1.X2
1.X2
1.X3
1.X3
1.X4
1.X4
M22-K10
216376
20 off
M22-K01
216378
20 off
Circuit-breakers, switch-disconnectors
Auxiliary contacts with screwterminals/spring-cage terminal
NZM1, M22-...
1.6
HPL17107EN
Part no.
Article no.
when ordered
separately
Price
See price
list
M22-CK10
216384
20 off
M22-CK01
216385
Std. pack
Notes
Notes
M22-CK11
107940
M22-CK02
107899
M22-CK20
107898
2)
M22-CK10
216384
20 off
M22-CK01
216385
20 off
M22-CK11
107940
20 off
M22-CK02
107899
20 off
M22-CK20
107898
20 off
Product Standards
UL File No.
UL CCN
(C)K.
NZM4 up to two trip-indicating auxiliary switches M22
Any combinations of the auxiliary contact types are possible.
Not in combination with switch-disconnector PN
Marking on switch: HIA
Labeling in residual-current block: HIAFI.
If the trip-indicating auxiliary contacts are used in the residual-current block,
the NC contacts operates as N/O contacts and the N/O contact operates as an
NC contact.
022086
1437-01
UL Listed, CSA certified
107
1.6
Circuit-breakers, switch-disconnectors
Undervoltage releases
1 NZM1
For use with
Part no.
Article no. for
separate order
Price
See price
list
Std. pack
Notes
Undervoltage releases
Without auxiliary contacts
Non-delayed disconnection of circuit-breaker NZM or switch-disconnector N
when control voltage drops below 35 70% US.
For use with emergency switching off devices in conjunction with emergency
switching off button.
NZM1(-4),
24 V 50/60 Hz
N(S)1(-4)
48 V 50/60 Hz
With clamp
terminal on left
60 V 50/60 Hz
switch side.
110 V-130 V 50/60 Hz
208 V-240 V 50/60 Hz
380 V-440 V 50/60 Hz
480 V-525 V 50/60 Hz
600 V 50/60 Hz
12 V DC
24 V DC
110 V-130 V DC
220 V-250 V DC
With 3 m connection
cable instead of
screw terminal.
NZM1(-4),
N(S)1(-4)
24 V 50/60 Hz
110 V-130 V 50/60 Hz
208 V-240 V 50/60 Hz
380 V-440 V 50/60 Hz
480 V-525 V 50/60 Hz
600 V 50/60 Hz
12 V DC
24 V DC
110 V-130 V DC
220 V-250 V DC
108
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
NZM1-XU24AC
259434
NZM1-XU48AC
259436
NZM1-XU60AC
259438
NZM1-XU110-130AC
259440
NZM1-XU208-240AC
259442
NZM1-XU380-440AC
259444
NZM1-XU480-525AC
259446
NZM1-XU600AC
259448
NZM1-XU12DC
259450
NZM1-XU24DC
259452
NZM1-XU110-130DC
259458
NZM1-XU220-250DC
259460
NZM1-XUL24AC
259462
NZM1-XUL110-130AC
259468
NZM1-XUL208-240AC
259471
NZM1-XUL380-440AC
259473
NZM1-XUL480-525AC
259475
NZM1-XUL600AC
259477
NZM1-XUL12DC
259479
NZM1-XUL24DC
259481
NZM1-XUL110-130DC
259487
NZM1-XUL220-250DC
259489
1 off
When the undervoltage release
is de-energized, accidental
contact with the main contacts
of the switch during attempts to
switch on is reliably prevented.
Undervoltage releases cannot be
installed simultaneously with
early-make auxiliary contact
NZM...-XHIV... or shunt release
NZM...-XA...
1 off
Circuit-breakers, switch-disconnectors
Undervoltage releases
1.6
NZM2/3..., NZM4
For use with
Part no.
Article no. when ordered
separately
Price
See price
list
Std. pack
Notes
1 off
Undervoltage releases
Without auxiliary
contacts
Non-delayed disconnection of circuit-breaker NZM or switchdisconnector N when control voltage drops below 35 70% US .
For use with emergency switching off devices in conjunction with
emergency switching off button
NZM2(-4), N(S)2(-4)
24 V 50/60 Hz
NZM3(-4), N(S)3(-4)
48 V 50/60 Hz
60 V 50/60 Hz
110 V-130 V 50/60 Hz
208 V-240 V 50/60 Hz
380 V-440 V 50/60 Hz
480 V-525 V 50/60 Hz
600 V 50/60 Hz
12 V DC
24 V DC
110 V-130 V DC
220 V-250 V DC
NZM4(-4), N(S)4(-4)
24 V 50/60 Hz
48 V 50/60 Hz
60 V 50/60 Hz
110 V-130 V 50/60 Hz
208 V-240 V 50/60 Hz
380 V-440 V 50/60 Hz
480 V-525 V 50/60 Hz
600 V 50/60 Hz
12 V DC
24 V DC
110 V-130 V DC
220 V-250 V DC
NZM2/3-XU24AC
259491
NZM2/3-XU48AC
259493
NZM2/3-XU60AC
259495
NZM2/3-XU110-130AC
259497
NZM2/3-XU208-240AC
259499
NZM2/3-XU380-440AC
259501
NZM2/3-XU480-525AC
259503
NZM2/3-XU600AC
259505
NZM2/3-XU12DC
259507
NZM2/3-XU24DC
259509
NZM2/3-XU110-130DC
259515
NZM2/3-XU220-250DC
259517
NZM4-XU24AC
266189
NZM4-XU48AC
266190
NZM4-XU60AC
266191
NZM4-XU110-130AC
266192
NZM4-XU208-240AC
266193
NZM4-XU380-440AC
266194
NZM4-XU480-525AC
266195
NZM4-XU600AC
266196
NZM4-XU12DC
266203
NZM4-XU24DC
266204
NZM4-XU110-130DC
266207
NZM4-XU220-250DC
266208
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
1 off
109
1.6
Circuit-breakers, switch-disconnectors
Undervoltage releases
NZM1, NZM2/3
For use
with
Part no.
Article no. for
separate order
Price
See price
list
Std. pack
Notes
Undervoltage releases
D1
3.13
D2
3.14
D1
3.13
D2
3.14
D1
3.13
D2
3.14
With two early-make auxiliary contacts,For interlocking and load-shedding circuits, as well as for early-make of the undervoltage release in main-switch applications.
For use with emergency switching off devices in conjunction with emergency switching off button.
1 off
With clamp
NZM1(-4),
24 V 50/60 Hz
NZM1-XUHIV24AC
When the undervoltage release is
de-energized, accidental contact
terminal on left
N(S)1(-4)
259531
with the main contacts of the
switch side.
48 V 50/60 Hz
NZM1-XUHIV48AC
switch during attempts to switch
259533
on is reliably prevented.
60 V 50/60 Hz
NZM1-XUHIV60AC
Early-make of auxiliary contacts
259535
on switching on and off (manual
operation): approx. 20 ms
110 V-130 V 50/60 Hz
NZM1-XUHIV110-130AC
Undervoltage releases cannot be
259537
installed simultaneously with
208 V-240 V 50/60 Hz
NZM1-XUHIV208-240AC
early-make auxiliary contact
259539
NZM...-XHIV... or shunt release
380 V-440 V 50/60 Hz
NZM1-XUHIV380-440AC
NZM...-XA... .
259541
480 V-525 V 50/60 Hz
NZM1-XUHIV480-525AC
259543
12 V DC
NZM1-XUHIV12DC
259545
24 V DC
NZM1-XUHIV24DC
259547
110 V-130 V DC
NZM1-XUHIV110-130DC
259553
220 V-250 V DC
NZM1-XUHIV220-250DC
259555
1 off
24 V 50/60 Hz
NZM1-XUHIVL24AC
NZM1(-4),
With 3 m
259557
connection
N(S)1(-4)
cable instead of
110 V-130 V 50/60 Hz
NZM1-XUHIVL110-130AC
screw
259563
connection.
208 V-240 V 50/60 Hz
NZM1-XUHIVL208-240AC
259565
380 V-440 V 50/60 Hz
NZM1-XUHIVL380-440AC
259567
480 V-525 V 50/60 Hz
NZM1-XUHIVL480-525AC
259569
12 V DC
NZM1-XUHIVL12DC
259571
24 V DC
NZM1-XUHIVL24DC
259573
110 V-130 V DC
NZM1-XUHIVL110-130DC
259579
220 V-250 V DC
NZM1-XUHIVL220-250DC
259581
1 off
NZM2(-4),
24 V 50/60 Hz
NZM2/3-XUHIV24AC
When the undervoltage release is
de-energized, accidental contact
N(S)2(-4)
259583
NZM3(-4),
with the main contacts of the
48 V 50/60 Hz
NZM2/3-XUHIV48AC
switch during attempts to switch
N(S)3(-4)
259585
on is reliably prevented.
60 V 50/60 Hz
NZM2/3-XUHIV60AC
Early-make of auxiliary contacts
259587
on switching on and off (manual
operation): approx. 20 ms
110 V-130 V 50/60 Hz
NZM2/3-XUHIV110-130AC
Cannot be used in conjunction
259589
with remote operator NZM...-XR....
NZM2/3-XUHIV208-240AC
208 V-240 V 50/60 Hz
Undervoltage releases cannot be
259591
installed simultaneously with
380 V-440 V 50/60 Hz
NZM2/3-XUHIV380-440AC
early-make auxiliary contact
259594
NZM...-XHIV... or shunt release
NZM...-XA....
480 V-525 V 50/60 Hz
NZM2/3-XUHIV480-525AC
12 V DC
24 V DC
110 V-130 V DC
220 V-250 V DC
110
259598
NZM2/3-XUHIV12DC
259600
NZM2/3-XUHIV24DC
259602
NZM2/3-XUHIV110-130DC
259608
NZM2/3-XUHIV220-250DC
259610
Circuit-breakers, switch-disconnectors
Undervoltage releases
1.6
D1
3.13
D2
3.14
D1
3.13
3.23
D2
3.14
3.24
D1
3.13
3.23
D2
3.14
3.24
Rated operating
voltage
Us
V
Part no.
Price
Std. pack Notes
Article no. See
when ordered price list
separately
Undervoltage releases
With two early-make auxiliary contacts
For interlocking and load-shedding circuits, as well as for early-make
of the undervoltage release in main-switch applications.
For use with emergency switching off devices in conjunction with
emergency switching off button.
NZM4(-4),
24 V 50/60 Hz
NZM4-XUHIV24AC
N(S)4(-4)
266217
48 V 50/60 Hz
NZM4-XUHIV48AC
266218
60 V 50/60 Hz
NZM4-XUHIV60AC
266219
110 V-130 V 50/60 Hz
NZM4-XUHIV110-130AC
266220
208 V-240 V 50/60 Hz
NZM4-XUHIV208-240AC
266221
380 V-440 V 50/60 Hz
NZM4-XUHIV380-440AC
266222
480 V-525 V 50/60 Hz
NZM4-XUHIV480-525AC
266223
12 V DC
NZM4-XUHIV12DC
266231
24 V DC
NZM4-XUHIV24DC
266232
110 V-130 V DC
NZM4-XUHIV110-130DC
266235
220 V-250 V DC
NZM4-XUHIV220-250DC
266236
With 2 separate early-make auxiliary contacts
With 3 m connection cable instead of screw terminal.
NZM1(-4),
24 V 50/60 Hz
NZM1-XUHIV20L24AC
N(S)1(-4)
259612
110 V-130 V 50/60 Hz
NZM1-XUHIV20L110-130AC
259620
208 V-240 V 50/60 Hz
NZM1-XUHIV20L208-240AC
259622
380 V-440 V 50/60 Hz
NZM1-XUHIV20L380-440AC
259624
24 V DC
NZM1-XUHIV20L24DC
259630
Contacts 3.23 and 3.24 with separate 3 m connection cables.
NZM2(-4),
24 V 50/60 Hz
NZM2/3-XUHIV2024AC
N(S)2(-4)
259640
NZM3(-4),
110 V-130 V 50/60 Hz
NZM2/3-XUHIV20110-130AC
N(S)3(-4)
259648
208 V-240 V 50/60 Hz
NZM2/3-XUHIV20208-240AC
259651
380 V-440 V 50/60 Hz
NZM2/3-XUHIV20380-440AC
259653
24 V DC
NZM2/3-XUHIV2024DC
259659
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
1 off
1 off
1 off
111
1.6
Circuit-breakers, switch-disconnectors
Undervoltage releases
For use
with
D1
3.13
3.23
D2
3.14
3.24
D1
3.13
3.23
D2
3.14
3.24
D1
3.13
3.23
D2
3.14
3.24
D1
3.13
3.23
D2
3.14
3.24
Price
See price
list
Std. pack
Notes
1 off
Undervoltage releases
With 2 separate early-make auxiliary contacts
For use with emergency switching off devices in conjunction with emergency
switching off button.
Coil connections wired to clamp terminals, auxiliary contact connections with
3 m loose connection cables.
NZM1(-4), 24 V 50/60 Hz
NZM1-XUHIV20KL24AC
N(S)1(-4)
284388
110 V-130 V 50/60 Hz
NZM1-XUHIV20KL110-130AC
284389
208 V-240 V 50/60 Hz
NZM1-XUHIV20KL208-240AC
284400
24 V DC
NZM1-XUHIV20KL24DC
284387
Coil connections with 3 m loose connection cables, auxiliary contact connections wired to clamp terminals.
NZM1(-4), 24 V 50/60 Hz
NZM1-XUHIV20LK24AC
N(S)1(-4)
284402
110 V-130 V 50/60 Hz
NZM1-XUHIV20LK110-130AC
284403
208 V-240 V 50/60 Hz
NZM1-XUHIV20LK208-240AC
284404
24 V DC
NZM1-XUHIV20LK24DC
284401
NZM2(-4), 24 V 50/60 Hz
NZM2/3-XUHIV20LK24AC
N(S)2(-4)
285291
NZM3(-4), 110 V-130 V 50/60 Hz
NZM2/3-XUHIV20LK110-130AC
N(S)3(-4)
284407
208 V-240 V 50/60 Hz
NZM2/3-XUHIV20LK208-240AC
284408
24 V DC
NZM2/3-XUHIV20LK24DC
284405
112
Part no.
Article no. when ordered
separately
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
1 off
1 off
1 off
Undervoltage release
cannot be installed simultaneously with early-make
auxiliary contact NZM...XHIV... or shunt release
NZM...-XA...
Circuit-breakers, switch-disconnectors
Undervoltage releases, off-delayed
Part no.
Article no.
when ordered
separately
Price
See price
list
1.6
1
Std. pack
Notes
1 off
1 off
1 off
D1
U
D2
D1
3.13
D2
3.14
D1
3.13
3.23
D2
3.14
3.24
1 off
113
1.6
Circuit-breakers, switch-disconnectors
Shunt releases
Rated cntrol
voltage
Us
V
Part no.
Article no. when ordered
Price
See price
Std. pack
Notes
1 off
Shunt releases
C1
C2
C1
C2
C1
C2
C1
C2
114
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
1 off
1 off
1 off
Circuit-breakers, switch-disconnectors
Shunt releases
1.6
NZM...-XA...
With screw terminal
For use with
Part no.
Article no.
Price
See price
list
Std. pack
Notes
1 off
Shunt releases
Capacitor unit 230 V 50/60 Hz
in conjunction with shunt release
NZM...-XA208-250 AC/DC
Enclosure: degree of protection IP20
Not UL/CSA approved
NZM1(-4),
NZM-XCM
N(S)1(-4)
229413
NZM2(-4),
N(S)2(-4)
NZM3(-4),
N(S)3(-4)
NZM4(-4),
N(S)4(-4)
Part no.
Article no.
With screw terminal
Price
See price
list
Std. pack
Notes
Shunt releases
C1
NZM3-XA-230AC-MNS
274097
1 off
With early-make
auxiliary contact
NZM3-XAHIV-230AC-MNS
274141
1 off
Without auxiliary
contacts
NZM4-XA-230AC-MNS
274138
With early-make
auxiliary contact
NZM4-XAHIV-230AC-MNS
274143
C2
C1
3.13
C2
3.14
L1 (L+)
C1
C2
C1
3.13
C2
3.14
1 off
Q
HIN
-S11
0
1.13
M22-...K10
1.14
C1
-Q1
NZM...-XA...-MNS
C2
N (L-, L2)
NZM...-XAHIV:
Cannot be used in conjunction with remote operator
NZM...-XR....
NZM3: Early make of auxiliary contact
on switching on and off (manual operation):
approx. 20 ms.
NZM4: Early make of auxiliary contact on switching on
(manual operation): approx. 90 ms.
-S11
q
-Q1
115
Circuit-breakers, switch-disconnectors
1.6
Shunt releases
Rated control
voltage
Us
V
Part no.
Article no. when ordered
separately
Price
See price
list
Std. pack
Notes
NZM1-XAHIV12AC/DC
259772
NZM1-XAHIV24AC/DC
259774
NZM1-XAHIV48AC/DC
259776
NZM1-XAHIV60AC/DC
259778
NZM1-XAHIV110-130AC/DC
259780
NZM1-XAHIV208-250AC/DC
259782
NZM1-XAHIV380-440AC/DC
259784
1 off
NZM1-XAHIVL12AC/DC
259790
NZM1-XAHIVL24AC/DC
259792
NZM1-XAHIVL110-130AC/DC
259798
NZM1-XAHIVL208-250AC/DC
259800
NZM1-XAHIVL380-440AC/DC
259802
1 off
NZM2/3-XAHIV12AC/DC
259808
NZM2/3-XAHIV24AC/DC
259810
NZM2/3-XAHIV48AC/DC
259812
NZM2/3-XAHIV60AC/DC
259814
NZM2/3-XAHIV110-130AC/DC
259816
NZM2/3-XAHIV208-250AC/DC
259818
NZM2/3-XAHIV380-440AC/DC
259820
NZM4-XAHIV12AC/DC
266470
NZM4-XAHIV24AC/DC
266471
NZM4-XAHIV48AC/DC
266472
NZM4-XAHIV60AC/DC
266473
1 off
Shunt releases
With early-make auxiliary contact
Not in combination with remote operator.
With clamp
NZM1(-4), N(S)1(-4)
12 V AC/DC
terminal on
left switch
24 V AC/DC
side.
48 V AC/DC
C1
3.13
C2
3.14
60 V AC/DC
110 V-130 V AC/DC
208 V-250 V AC/DC
380 V-440 V AC/DC
With 3 m
connection
cable
instead of
screw
connection
NZM1(-4), N(S)1(-4)
12 V AC/DC
24 V AC/DC
110 V-130 V AC/DC
208 V-250 V AC/DC
C1
3.13
C2
3.14
NZM2(-4), N(S)2(-4)
NZM3(-4), N(S)3(-4)
12 V AC/DC
24 V AC/DC
48 V AC/DC
60 V AC/DC
110 V-130 V AC/DC
C1
3.13
C2
3.14
12 V AC/DC
24 V AC/DC
48 V AC/DC
60 V AC/DC
3.13
C2
3.14
116
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
1 off
NZM4-XAHIV110-130AC/DC
266474
NZM4-XAHIV208-250AC/DC
266475
NZM4-XAHIV380-440AC/DC
266476
UL489; CSA-C22.2 No. 5-09; IEC60947, CE marking
E140305
DIHS
022086
1437-01
UL Listed, CSA certified
Circuit-breakers, switch-disconnectors
Mechanical interlock for (door-coupling) rotary handles
1.6
1
117
Circuit-breakers, switch-disconnectors
1.6
F o r u s e w ith
Part no.
Article no.
when
ordered
separately
Price
See price
list
Std. pack
Notes
Red-yellow
for emergency
witching off
Extension shaft
Notes
118
NZM3(-4), PN3(-4),
N(S)3(-4)
NZM3-XTVD
260170
NZM4(-4), N(S)4(-4)
NZM4-XTVD
266614
NZM1(-4), PN1(-4),
N(S)1(-4)
NZM1-XTVDV
260172
NZM2(-4), PN2(-4),
N(S)2(-4)
NZM2-XTVDV
260174
NZM3(-4), PN3(-4),
N(S)3(-4)
NZM3-XTVDV
260176
NZM4(-4), N(S)4(-4)
NZM4-XTVDV
266616
NZM1(-4), PN1(-4),
N(S)1(-4)
NZM1-XTVDVR
260178
NZM2(-4), PN2(-4),
N(S)2(-4)
NZM2-XTVDVR
260180
NZM3(-4), PN3(-4),
N(S)3(-4)
NZM3-XTVDVR
260182
NZM4(-4), N(S)4(-4)
NZM4-XTVDVR
266618
1 off
Door interlock
Not defeated in the
locked OFF and ON
positions
Can be modified such that
it can be defeated from
the outside using a
screwdriver, when it is in
the unlocked ON position.
Door can be opened in
OFF
NZM-XTVD(V)
External warning plate/
designation label can be
clipped on
1 off
Door interlock
Not defeated in the
locked OFF position.
Can be modified such that
it can be defeated from
the outside using a
screwdriver, when it is in
the unlocked ON position.
Door can be opened in
OFF
NZM-XTVDVR
External warning plate/
designation label can be
clipped on
NZM1(-4), PN1(-4),
Length 290 mm, can be cut to
NZM1/2-XV4
1 off
N(S)1(-4)
required length.
261232
NZM2(-4), PN2(-4),
N(S)2(-4)
NZM3(-4), PN3(-4),
NZM3/4-XV4
N(S)3(-4)
261234
NZM4(-4), N(S)4(-4)
Length 425 mm, can be cut to
600 mm max. mounting depth
NZM1(-4), PN1(-4),
NZM1/2-XV6
required length.
N(S)1(-4)
260191
NZM2(-4), PN2(-4),
N(S)2(-4)
NZM3(-4), PN3(-4),
NZM3/4-XV6
N(S)3(-4)
260193
NZM4(-4), N(S)4(-4)
Circuit-breaker can also be installed in a horizontal position 90 left/right, with the handle still in the same position.
Circuit-breakers, switch-disconnectors
1.6
NZM1-XTVD-60
271504
Std. pack
Notes
1 off
Door interlock
Can not be defeated in
the locked OFF and ON
positions
Can be modified such
that it can be defeated
from the outside using
a screwdriver, when it
is in the unlocked ON
position.
Door can be opened in
OFF
NZM-XTVD(V)-60
For maximum shaft
length 60 mm
Without shaft support
Cannot be combined
with additional handle
NZM...-XDZ
External warning
plate/designation label
can be clipped on.
NZM2-XTVD-60
271505
NZM3-XTVD-60
271506
NZM4-XTVD-60
271507
NZM1-XTVDV-60
271508
NZM2-XTVDV-60
271509
NZM3-XTVDV-60
271510
NZM4-XTVDV-60
271511
NZM1-XTVDVR-60
271512
NZM2-XTVDVR-60
271513
NZM3-XTVDVR-60
271514
NZM4-XTVDVR-60
271515
Extremely narrow
fittings
Part no.
Price
Article no.
See price
when
list
ordered
separately
NZM1-XTVD-0
279392
1
Note
Std. pack
1 off
NZM2-XTVD-0
279393
NZM3-XTVD-0
279394
NZM4-XTVD-0
279395
NZM1-XTVDV-0
279396
NZM2-XTVDV-0
279397
NZM3-XTVDV-0
279398
Door interlock
Can not be defeated in
the locked OFF and ON
positions
Can be modified such
that it can be defeated
from the outside using a
screwdriver, when it is
in the unlocked ON
position.
Door can be opened in
OFF
NZM-XTVD(V)-0
For extremely narrow
fittings
With special short
extension shaft
Cannot be combined
with additional handle
NZM...-XDZ
External warning plate/
designation label can
be clipped on.
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
UL489;
CSA-C22.2
No. 5-09;
IEC60947,
CE marking
E140305
DIHS
022086
UL Listed,
CSA certified
Degree of Protection
IEC: IP66,
UL/CSA
Type 4X, 12
NZM4-XTVDV-0
279399
1 off
Door interlock
Can not be defeated in
the locked OFF position.
Can be modified such
that it can be defeated
from the outside using
a screwdriver, when it
is in the unlocked ON
position.
Door can be opened in
OFF
NZM-XTVDVR-60
For maximum shaft
length 60 mm
Without shaft support
Cannot be combined
with additional handle
NZM...-XDZ
External warning
plate/designation label
can be clipped on.
NZM1-XTVDVR-0
279400
NZM2-XTVDVR-0
279401
NZM3-XTVDVR-0
279402
NZM4-XTVDVR-0
279403
1 off
Door interlock
Can not be defeated in
the locked OFF position.
Can be modified such
that it can be defeated
from the outside using a
screwdriver, when it is
in the unlocked ON
position.
Door can be opened in
OFF
NZM-XTVDVR-0
For extremely narrow
fittings
With special short
extension shaft
Cannot be combined
with additional handle
NZM...-XDZ
External warning plate/
designation label can
be clipped on.
U L /C S A c e r tific a tio n n o t r e q u ir e d
119
Circuit-breakers, switch-disconnectors
1.6
HPL17120EN
Part no.
Article no. when
ordered separately
Price
See
price list
NZM1-XTVD-NA
271445
NZM2-XTVD-NA
271446
NZM3-XTVD-NA
271447
NZM4-XTVD-NA
271448
1 off
Door interlock
Can not be defeated in the locked
OFF position.
Door opening with active rotation
beyond the 0 position.
Cannot be combined with mechanical
interlock
External warning plate/designation
label can be clipped on.
NZM1-XTVDV-NA
100683
NZM2-XTVDV-NA
100684
NZM3-XTVDV-NA
100685
NZM4-XTVDV-NA
100686
1 off
Door interlock
Can not be defeated in the locked
OFF position.
Door opening possible with active
rotation beyond the 0 position. Can be
defeated from the outside using a
screwdriver.
Cannot be combined with mechanical
interlock
External warning plate/designation
label can be clipped on.
NZM1, N(S)1
NZM1-XTVDVR-NA
271449
1 off
NZM2, N(S)2
NZM2-XTVDVR-NA
271450
NZM3, N(S)3
NZM3-XTVDVR-NA
271451
Door interlock
Can not be defeated in the locked
OFF position.
Door opening with active rotation
beyond the 0 position.
Cannot be combined with mechanical
interlock
External warning plate/designation
label can be clipped on.
NZM4, N(S)4
NZM4-XTVDVR-NA
271452
NZM1, N(S)1
NZM2, N(S)2
NZM3, N(S)3
NZM4, N(S)4
Std. pack
Notes
Extension shaft
400 mm max.
mounting depth
Notes
120
Circuit-breakers, switch-disconnectors
Door coupling rotary handles for North America
1.6
HPL17121EN
Price
See
price list
Std. pack
Notes
Part no.
Article no.
NZM1XTVDV-60-NA
100667
1 off
NZM2XTVDV-60-NA
100668
NZM3XTVDV-60-NA
100669
NZM4XTVDV-60-NA
100670
NZM1XTVDVR-60-NA
100671
NZM2XTVDVR-60-NA
100672
NZM3XTVDVR-60-NA
100673
NZM4XTVDVR-60-NA
100674
1 off
Door interlock
Can not be defeated in
the locked OFF position.
Door opening possible
with active rotation
beyond the 0 position.
Can be defeated from
the outside using a
screwdriver.
Cannot be combined
with mechanical
interlock
External warning plate/
designation label can
be clipped on.
NZM-XTVDV-60-NA
For a maximum shaft
length of 60 mm
Without shaft support
Cannot be combined
with additional handle
NZM...-XDZ
External warning plate/
designation label can
be clipped on.
NZM1XTVDV-0-NA
100675
Door interlock
Can not be defeated in
the locked OFF position.
Door opening with
active rotation beyond
the 0 position.
Cannot be combined
with mechanical
interlock
External warning plate/
designation label can
be clipped on.
NZM-XTVDVR-60-NA
For a maximum shaft
length of 60 mm
Without shaft support
Cannot be combined
with additional handle
NZM...-XDZ
External warning plate/
designation label can
be clipped on.
NZM1XTVDVR-0-NA
100679
Price
See
price list
Std. pack
1 off
NZM2XTVDV-0-NA
100676
NZM3XTVDV-0-NA
100677
NZM4XTVDV-0-NA
100678
NZM2XTVDVR-0-NA
100680
NZM3XTVDVR-0-NA
100681
NZM4XTVDVR-0-NA
100682
1 off
Notes
P r o d u c t S ta n d a r d s
Door interlock
Can not be defeated in
the locked OFF position.
Door opening possible
with active rotation
beyond the 0 position.
Can be defeated from
the outside using a
screwdriver.
Cannot be combined
with mechanical
interlock
External warning plate/
designation label can
be clipped on.
NZM-XTVDV-0-NA
For extremely narrow
fittings
With special short
extension shaft
Cannot be combined
with additional handle
NZM...-XDZ
External warning plate/
designation label can
be clipped on.
Door interlock
Can not be defeated in
the locked OFF position.
Door opening with
active rotation beyond
the 0 position.
Cannot be combined
with mechanical
interlock
External warning plate/
designation label can
be clipped on.
NZM-XTVDVR-0-NA
For extremely narrow
fittings
With special short
extension shaft
Cannot be combined
with additional handle
NZM...-XDZ
External warning plate/
designation label can
be clipped on.
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
UL489;
CSA-C22.2
No. 5-09;
IEC60947,
CE marking
E140305
DIHS
022086
1437-01
UL Listed,
CSA certified
Degree of Protection
IEC: IP66, UL/
CSA Type 4X,
12
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
UL489;
CSA-C22.2
No. 5-09;
IEC60947,
CE marking
E140305
DIHS
022086
1437-01
UL Listed,
CSA certified
Degree of Protection
IEC: IP66, UL/
CSA Type 4X,
12
U L /C S A c e r tific a tio n n o t
required
121
Circuit-breakers, switch-disconnectors
1.6
Rotary handles
1 NZM...-XDV
For use with
Part no.
Article no. for
separate
order
NZM1-XDV
260125
NZM2-XDV
260127
NZM3-XDV
260129
NZM4(-4), N(S)4(-4)
NZM4-XDV
266608
NZM1-XDVG
285247
NZM2-XDVG
285248
NZM1-XDVR
260135
NZM2-XDVR
260137
NZM3-XDVR
260140
NZM4(-4), N(S)4(-4)
NZM4-XDVR
266610
NZM1-XDVGR
285249
NZM2-XDVGR
285280
Price
See
price
list
Std. pack
Notes
1 off
NZM1, 2, 3: Can
also be combined
with insulating
surround.
MODAN handle
position detection
by wire release
can be retrofitted
Product Standards
Lockable in
0 position on
handle with upto
3 padlocks.
Lockable in
0 position on
handlewith upto
3 padlocks.
Notes
122
1 off
Can also be
combined with
insulating
surround
1 off
NZM1, 2, 3: Can
also be combined
with insulating
surround.
MODAN handle
position detection
by wire release
can be retrofitted
1 off
Can also be
combined with
insulating
surround
Circuit-breaker can also be installed in a lying position 900 1eright, with the handle still in the same position
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
UL489;
CSA-C22.2
N o. 5-09;
IEC60947,
CE marking
E140305
DIHS
022086
1437-01
UL Listed,
CSA certified
UL489;
CSA-C22.2
N o. 5-09;
IEC60947,
CE marking
E140305
DIHS
022086
1437-01
UL Listed,
CSA certified
Circuit-breakers, switch-disconnectors
Rotary handles with door interlock
1.6
NZM...-XDTV
For use with
Part no.
Article no. for
separate
order
Price
See
price
list
NZM1(-4), PN1(-4),
N(S)1(-4)
NZM1-XDTV
260131
NZM2(-4), PN2(-4),
N(S)2(-4)
NZM2-XDTV
260133
NZM1(-4), PN1(-4),
N(S)1(-4)
NZM1-XDTVR
260142
NZM2(-4), PN2(-4),
N(S)2(-4)
NZM2-XDTVR
260144
NZM1, N(S)1
NZM1-XDTV-NA
271453
NZM2, N(S)2
NZM2-XDTV-NA
271454
NZM1, N(S)1
NZM1-XDTVR-NA
271455
NZM2, N(S)2
NZM2-XDTVR-NA
271456
Std. pack
Notes
1 off
In the ON position,
can be defeatedfrom
the outside using a
1 mm pin
.Can not be defeated
inthe locked OFF and
ON positions
Door can be opened
in OFF
.Can onlybe switched
ON when the door is
closed
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
UL489;
CSA-C22.2
N o. 5-09;
IEC60947,
CE marking
E140305
DIHS
022086
1437-01
UL Listed,
CSA certified
1 off
Notes
1 off
Door interlock
In the ON position,
can be defeatedfrom
the outside using a
1 mm pin
.Can not be defeated
inthe locked OFF and
ON positions
Door opening only
possible with active
rotation beyondthe
0 position.
.Can onlybe switched
ON when the door is
closed
.Cannot be combined
with mechanical
interlock
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
UL489;
CSA-C22.2
N o. 5-09;
IEC60947,
CE marking
E140305
DIHS
022086
1437-01
UL Listed,
CSA certified
Circuit-breaker can also be installed in a lying position 900 leright, with the handle still in the same position
123
Circuit-breakers, switch-disconnectors
1.6
1 NZM...-XHB..., NZM...-XS...
Model
door interlock
Part no.
Article no.for
separate
order
Price
See
price list
Std. pack
For enhanced protection against direct contact on the incomer side, IP2X protection
against contact with a finger can be ordered Page 17/84
Other external warning plates/designation labels can be clipped on.
Degree of protection IP66/UL/CSA type 4X, 12
PN1(-4), N(S)1(-4)
NZM1-XHB
266626
PN2(-4), N(S)2(-4)
NZM2-XHB
266627
PN3(-4), N(S)3(-4)
NZM3-XHB
266628
N(S)4(-4)
NZM4-XHB
271779
PN1(-4), N(S)1(-4)
NZM1-XHBR
266632
PN2(-4), N(S)2(-4)
NZM2-XHBR
266633
PN3(-4), N(S)3(-4)
NZM3-XHBR
266634
N(S)4(-4)
NZM4-XHBR
271842
NZM1(-4)
PN1(-4), N(S)1(-4)
NZM1-XS-L
266641
NZM2(-4)
PN2(-4), N(S)2(-4)
NZM2-XS-L
266642
NZM3(-4)
PN3(-4), N(S)3(-4)
NZM3-XS-L
266643
NZM4(-4)
N(S)4(-4)
NZM4-XS-L
289806
NZM1(-4)
PN1(-4), N(S)1(-4)
NZM1-XS-R
266644
NZM2(-4)
PN2(-4), N(S)2(-4)
NZM2-XS-R
266645
NZM3(-4)
PN3(-4), N(S)3(-4)
NZM4(-4)
N(S)4(-4)
NZM3-XS-R
266646
NZM1(-4)
PN1(-4), N(S)1(-4)
NZM1-XSR-L
266653
NZM2(-4)
PN2(-4), N(S)2(-4)
NZM2-XSR-L
266654
NZM3(-4)
PN3(-4), N(S)3(-4)
NZM3-XSR-L
266655
NZM4(-4)
N(S)4(-4)
NZM4-XSR-L
289808
NZM1(-4)
PN1(-4), N(S)1(-4)
NZM1-XSR-R
266656
NZM2(-4)
PN2(-4), N(S)2(-4)
NZM2-XSR-R
266657
NZM3(-4)
PN3(-4), N(S)3(-4)
NZM3-XSR-R
266658
NZM4(-4)
N(S)4(-4)
NZM4-XSR-R
289809
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Degree of Protection
UL489;
CSA-C22.2
No. 5-09;
IEC60947,
CE marking
E140305
DIHS
022086
1437-01
UL Listed,
CSA certiPied
IEC:IP66,
UL/CSA
Type 4X,12
For
operation on
the left
For
operation on
the right
For
operation on
the left
For
operation on
the right
124
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Degree of Protection
UL489;
CSA-C22.2
No. 5-09;
IEC60947,
CE marking
E140305
DIHS
022086
1437-01
UL Listed,
CSA certiPied
IEC:IP66,
UL/CSA
Type 4X,12
NZM4-XS-R
289807
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Degree of Protection
UL489;
CSA-C22.2
No. 5-09;
IEC60947,
CE marking
E140305
DIHS
022086
1437-01
UL Listed,
CSA certiPied
IEC:IP66,
UL/CSA
Type 4X,12
Circuit-breakers, switch-disconnectors
Mechanical interlock for (door-coupling) rotary handles
1.6
NZM...XS(R)M...
1
Model
Part no.
Article no. when
ordered separately
Price
See
price
list
Std. pack
1 off
Product Standards
Main switch assembly kit for side wall installation with mounting
bracket.
For direct mounting of circuit-breaker and handle in the side wall of the control cabinet
Equipment supplied:
.Door coupling rotary handle
.Mounting bracket
.Special short extension shaft
.External warning plate/designation label in German/English
.Black and yellowflash
For enhanced protection against direct contact on the incomer side,
IP2X protection against contact with a finger can be ordered } Page 17/84
Other external warning plates/designation labels can be clipped on.
Degree of protection IP66/UL/CSAtype 4X, 12
Standard, black/grey
Lockable in 0 position
with adequate
modification also in
I position. Minimum
clearance between
control panel side
walls and circuitbreaker is defined by
mounting bracket.
Extension cannot be
used
For
operation
on the left
NZM1(-4)
PN1(-4), N(S)1(-4)
NZM1-XSM-L
266663
For
operation
on the left
NZM2(-4)
PN2(-4), N(S)2(-4)
NZM2-XSM-L
266664
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
For
operation
on the left
NZM1(-4)
PN1(-4), N(S)1(-4)
NZM1-XSM-R
266665
Degree of Protection
For
operation
on the left
NZM2(-4)
PN2(-4), N(S)2(-4)
NZM2-XSM-R
266666
For
operation
on the left
NZM1(-4)
PN1(-4), N(S)1(-4)
NZM1-XSRM-L
266671
For
operation
on the left
NZM2(-4)
PN2(-4), N(S)2(-4)
NZM2-XSRM-L
266672
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
For
operation
on the left
NZM1(-4)
PN1(-4), N(S)1(-4)
NZM1-XSRM-R
266673
Degree of Protection
For
operation
on the left
NZM2(-4)
PN2(-4), N(S)2(-4)
NZM2-XSRM-R
266674
1 off
Product Standards
UL489;
CSA-C22.2
N o. 5-09;
IEC60947,
CE marking
E140305
DIHS
022086
1437-01
UL Listed,
CSA certified
IEC:IP66,
UL/CSA
Type 4X,12
UL489;
CSA-C22.2
N o. 5-09;
IEC60947,
CE marking
E140305
DIHS
022086
1437-01
UL Listed,
CSA certified
IEC:IP66,
UL/CSA
Type 4X,12
Additional plate
For fitting to the mounting bracket when using neutral conductor or
PE conductor terminals K25. K50. K95 or K150.
Notes
PN1(-4), N(S)1(-4)
NZM2(-4),
N(S)2(-4)
NZM1/2-XZB
266676
1 off
Additional terminal arrangement for side wall operator with mounting bracket
Engineering, Page 17/153
125
1.6
Circuit-breakers, switch-disconnectors
Main switch assembly kit
1 NZM...XS(R)M...
Model
Part no.
Article no. when
ordered separately
Price
See
price
list
Std. pack
126
IEC
NZM1(-4)
PN1(-4), N1(-4)
NZM1-XHB-DA
125956
UL/CSA
NZM1(-4)
PN1(-4), N(S)1(-4)
NZM1-XHB-DA-NA
125958
IEC
NZM2(-4)
PN2(-4), N(S)2(-4)
NZM2-XHB-DA
116895
UL/CSA
NZM2(-4)
PN2(-4), N(S)2(-4)
NZM2-XHB-DA-NA
116897
IEC
NZM3(-4)
PN3(-4), N(S)3(-4)
NZM3-XHB-DA
118988
UL/CSA
NZM3(-4)
PN3(-4), N(S)3(-4)
NZM3-XHB-DA-NA
119000
IEC
NZM4(-4)
PN4(-4), N(S)4(-4)
NZM4-XHB-DA
119002
UL/CSA
NZM4(-4)
PN4(-4), N(S)4(-4)
NZM4-XHB-DA-NA
119004
IEC
NZM1(-4)
PN1(-4), N1(-4)
NZM1-XHB-DAR
125957
UL/CSA
NZM1(-4)
PN1(-4), N(S)1(-4)
NZM1-XHB-DAR-NA
125959
IEC
NZM2(-4)
PN2(-4), N(S)2(-4)
NZM2-XHB-DAR
116896
UL/CSA
NZM2(-4)
PN2(-4), N(S)2(-4)
NZM2-XHB-DAR-NA
116898
IEC
NZM3(-4)
PN3(-4), N(S)3(-4)
NZM3-XHB-DAR
118989
UL/CSA
NZM3(-4)
PN3(-4), N(S)3(-4)
NZM3-XHB-DAR-NA
119001
IEC
NZM4(-4)
PN4(-4), N(S)4(-4)
NZM4-XHB-DAR
119003
UL/CSA
NZM4(-4)
PN4(-4), N(S)4(-4)
119005
NZM4-XHB-DAR-NA
1 off
1 off
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Degree of Protection
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Degree of Protection
UL489;
CSA-C22.2
N o. 5-09;
IEC60947,
CE marking
E140305
DIHS
022086
1437-01
UL Listed,
CSA certified
IEC:IP66,
UL/CSA
Type 4X,12
UL489;
CSA-C22.2
N o. 5-09;
IEC60947,
CE marking
E140305
DIHS
022086
1437-01
UL Listed,
CSA certified
IEC:IP66,
UL/CSA
Type 4X,12
Circuit-breakers, switch-disconnectors
Main switch assembly kit
1.6
1
For use with
Part no.
Article no.
Price
See price
list
Std. pack
Notes
Rear-mounted drives
For direct rear connection ofthe switchtothe side of the control panel or control panel door. Switch actuation on rearthrough side wall or control panel door.
For switch with toggle lever.For enhanced protection against direct contact on the incomer side,
IP2X protection against contact with a finger can be ordered Page 17/84. Degree of protection IP66, UL/CSA type 4X, 12
Standard, blacK/grey
Lockable in
0 position on
handle with up to
3 padlocks.
1 off
NZM1-XRAV
107245
NZM2-XRAV
107247
NZM1-XRAVR
107249
NZM2-XRAVR
107261
1 off
ZFS61/62NZM7
272525
10 off
1 off
German/English
German
N(S)1(-4)
NZM2(-4), PN2(-4),
N(S)2(-4)
NZM3(-4), PN3(-4),
N(S)3(-4)
NZM4(-4), N(S)4(-4)
English
ZFS62-NZM7
065957
French
ZFS63-NZM7
065958
Chinese
Chinese/English
ZFS82-NZM
104910
Chinese
ZFS83-NZM
105945
ZFS*-NZM7
999978
Further languages
Symbol
Blank
Circuit-breaker
symbol
ZFS-LS-NZM
104829
Switchdisconnector
symbol
ZFS-LTS-NZM
104828
Disconnector
symbol
ZFS-TS-NZM
115365
Blank
(for engraving or
printing)
ZFS60-NZM7
065896
10 off
10 off
Lightning symbol
Including terminal marking for main switch
U X L1
Small
V Y L2
Large
ZFS61-NZM7
051089
T1 N PEN
T2
L3 T3 PE
N(S)1(-4)
NZM2(-4), PN2(-4),
N(S)2(-4)
BPF-NZM7
217294
U
V
W
X
Y
Z
L1 T1 N PEN
L2 T2
L3 T3 PE
N(S)3(-4)
NZM4(-4), N(S)4(-4)
BPF-NZM10
231363
Product Standards UL File No.
UL CCN CSA File No.
CSA Class No. NA Certification
Degree of Protection
127
1.6
Circuit-breakers, switch-disconnectors
Side-mounted handle
1 NZM...-XSH...-NA
For use with
Part no.
Article no.
Price
See price
list
Std. pack
Notes
Lockable in 0-position on
handle with up to
3 padlocks, for 1 door of
an American style
control panel(door plus
wide bar beside the
door.
For each handle
1 additional mechanical
unit and 1 Bowden cable
is required.
ProductStandards
Side-mounted handle
For mounting outside the control panel door.
Actuation of a switch with toggle lever using a
Bowden cable and mechanical components
mounted on the front of the switch.
For switch with toggle lever.
Caution! Intended exclusively for use outside the
scope of validity of the IEC/EN 60947 area.
Handle, metal, black/red
Degree of
protection
UL/CSA
Type 12
NZM2-NA,
NS2-NA
NZM3-NA,
NS3-NA
NZM-XSHGVR12-NA
107269
NZM-XSHGVR4X-NA
107268
Degree of
protection
UL/CSA
Type 4X
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
UL489; CSA-C22.2
N o. 5-09
E140305
DIHS
236770
1437-01
Danraa of Prntartinn UL Listed,
CSA certified
IEC: IP66, UL/CSA
Type 12
ProductStandards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
UL489; CSA-C22.2
N o. 5-09
E140305
DIHS
236770
1437-01
Degree of Protection UL Listed,
CSA certified
IEC: IP66, UL/CSA
Type 4X
Mechanical unit
NZM2-NA,
NS2-NA
NZM3-NA,
NS3-NA
NZM2-XSHM-NA
107266
NZM3-XSHM-NA
107267
1 off
NZM2-NA,
NS2-NA
NZM3-NA,
NS3-NA
NZM-XSHBZ36-NA
107263
1 off
Bowden cables
Nominal
length 36"
91.4 cm
Nominal
length 48"
121.9 cm
Nominal
length 60"
152.4 cm
128
NZM-XSHBZ48-NA
107264
NZM-XSHBZ60-NA
107265
ProductStandards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
ProductStandards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
UL489; CSA-C22.2
N o. 5-09
E140305
DIHS
236770
1437-01
UL Listed,
CSA certified
UL489; CSA-C22.2
N o. 5-09
E140306
DIHS
236771
1437-02
UL Listed,
CSA certified
Circuit-breakers, switch-disconnectors
Mechanical interlock for (door-coupling) rotary handles
1.6
Part no.
Article no. when
ordered separately
Additional handle
Enables switching when control panel door is open
NZM1(-4), PN1(-4), N(S)1(-4)
NZM2(-4), PN2(-4), N(S)2(-4)
NZM1/2-XDZ
266621
NZM3/4-XDZ
266622
Price
See price
list
Std. pack
Notes
1 off
1 off
Insulating surround
For toggle levers, rotary handles with rotary drive and
remote operators
Degree of protection IP40
NZM1(-4)
PN1(-4), N(S)1(-4)
NZM1-XBR
260195
NZM2(-4)
PN2(-4), N(S)2(-4)
NZM3(-4)
PN3(-4), N(S)3(-4)
NZM4(-4)
N(S)4(-4)
NZM2-XBR
260197
NZM3-XBR
284645
NZM4-XBR
284646
NZM1-XKAV
260199
NZM2/3-XKAV
260201
1 off
Spacers
Enables fast and attractively priced offsetting of varying
construction sizeswith/without rotary handle or remote
operatortothe samefrontdepth
NZM1(-4), PN1(-4), N(S)1(-4)
NZM2(-4), PN2(-4), N(S)2(-4)
NZM1/2-XAB
260203
NZM3(-4)
PN3(-4), N(S)3(-4)
NZM4(-4)
N(S)4(-4)
NZM3-XAB
260211
Clips
Allows switches to be clipped orrto DIN rails
NZM1(-4)
PN1(-4)
N(S)1(-4)
NZM2(-4)
PN2(-4)
N(S)2(-4)
NZM1-XC35
260213
NZM2-XC75
260215
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
1 off
1 off
129
Circuit-breakers, switch-disconnectors
1.6
Mechanical interlock
1 NZM...XMV(R)(L), NZM-XBZ...
For use with
Part no.
Article no. for
separate order
NZM1(-4)
PN1(-4), N(S)1(-4)
NZM1-XMV
281581
NZM2(-4)
PN2(-4), N(S)2(-4)
NZM2-XMV
281582
NZM3(-4)
PN3(-4), N(S)3(-4)
NZM3-XMV
281583
NZM4-XMV
281584
Price
See
price list
Std. pack
Notes
NZM4(-4)
N(S)4(-4)
Allows interlocking of 2, 3
or 4 switches, including
different construction sized
switches, with Bowden
cables.
For every switch an interlocking
module NZM...-XMV and a
rotary handle on switch
NZM...-XDV or a door
coupling rotary handle
NZM...-XTVD and Bowden
cables are required.
Possible combinations and
interlock variants,
Engineering
Cannot be combined with
UL/CSA door coupling
rotary handles
NZM...-XTV...-NA,
paralleling mechanisms,
side wall operators, remote
operators or insulating
surrounds. Selection and
combinations of required
Bowden cables
Engineering
Product Standards
1 off
Product StandardsUL489;
CSA-C22.2
UL File No.
N o. 5-09;
UL CCN
IEC60947,
CSA File No.
CE marking
CSA Class No.
E140305
NA Certification
DIHS
022086
1437-01
UL Listed,
CSA
certified
1 off
1 off
1 off
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
UL489;
CSA-C22.2
N o. 5-09;
IEC60947,
CE marking
E140305
DIHS
022086
1437-01
UL Listed,
CSA
certified
Bowden cables
For mechanical interlock for (door coupling) rotary handles
Length:
NZM1(-4), PN1(-4),
225 mm
N(S)1(-4)
NZM2(-4), PN2(-4),
Length:
N(S)2(-4)
600 mm
NZM3(-4), PN3(-4),
Length:
N(S)3(-4)
1000 mm
NZM4(-4), N(S)4(-4)
NZM-XBZ225
281585
NZM-XBZ600
281586
NZM-XBZ1000
281587
NZM2-XMVRL
104548
NZM2/3-XMVRL
104549
NZM3-XMVRL
104550
NZM3/4-XMVRL
104551
NZM4-XMVRL
104552
Circuit-breakers, switch-disconnectors
Mechanical interlock,paralleling mechanism
1.6
PN...XPA. NZM...-XV...
For use with
Part no.
Price
Article no.
See
for separate order price list
Std. pack
Notes
PN1-XPA
283471
PN2-XPA
283472
1 off
PN1, PN2
1 x rotary handle on switch
(-XD) supplied.
1 x door coupling rotary handle
(-XTVD) supplied.
1
Information relevant
forexportto
North America
Paralleling mechanism
Simultaneous actuation of 2 PN switch-disconnectors of the same
type mounted side-by-side.
Not UL/CSA approved
switch-disconnectors of the same
PN1(-4) + PN1(-4)
PN2(-4) + PN2(-4)
PN3(-4) + PN3(-4)
PN3-XPA
283473
PN3
1 x rotary handle on switch
(not lockable) supplied.
1 x door coupling rotary handle
(not lockable) supplied.
Not suitable for use as a main
switch
Extension shaft(-XV4(6)) additionally required for the door coupling rotary handle.
Cannot be combined with mechanical interlock, insulating surrounds, side wall operators or remote operators
Notes
Notes
400 mm
max. builtin depth
NZM1(-4), PN1(-4),
N(S)1(-4)
NZM2(-4), PN2(-4),
N(S)2(-4)
NZM1/2-XV4
261232
600 mm
max. builtin depth
NZM3(-4), PN3(-4),
N(S)3(-4)
NZM4(-4), N(S)4(-4)
NZM3/4-XV4
261234
NZM1(-4), PN1(-4),
N(S)1(-4)
NZM2(-4), PN2(-4),
N(S)2(-4)
NZM1/2-XV6
260191
NZM3(-4), PN3(-4),
N(S)3(-4)
NZM4(-4), N(S)4(-4)
NZM3/4-XV6
260193
1 off
Ul/CSA certification
not required
Length 425 mm
can be cut to required length
Circuit-breaker can also be installed in a lying position 900 left/right, with the handle still in the same position
131
Circuit-breakers, switch-disconnectors
1.6
1 NZM...-XAD...
Number of
poles
Rated operational
current
Ie
A
Adapter with
mm
3 pole
160
90
NZM1,
PN1,
NIS11
250
106
NZM2,
PN2,
NIS12
630
140
NZM3,
PN3,
NIS13
250
140
NZM2-4,
PN2-4,
N 2-4
630
185
N Z-4
NZM3-4
PN3-4,
N 3-4
NZM2,
PN2,
N(S)2
+NZM2-XKR4O
281664
NZM2
PN2,
N(S)2
+NZM2-XKR4U
281665
NZM3,
PN3,
N(S)3
+NZM3-XKR13O
281667
NZM3-4,
PN3-4,
N (S)3-4
+NZM3-XKR13U
115796
NZM2-4,
PN2-4,
N(S)2-4
+NZM2-4-XKR4O
118905
NZM3,
PN3,
N(S)3
+NZM2-4-XKR4U
118906
NZM3-4,
PN3-4,
N(S)3-4
+NZM3-4-XKR13O
118908
NZM2-4,
PN2-4,
N (S)2-4
+NZM3-4-XKR13U
118909
250
Below
Above
3 pole
630
Below
Above
250
Below
Above
630
Below
132
Price
See price
list
Circuit-breakers, switch-disconnectors
Multi-function component adapterss
1.6
NZM-XAD
Part no.
Article no. for separate
order
NZM1-XAD160
104554
1
Price
See price
list
Std. pack
Notes
Information relevantforexportto
North America
1off
Product Standards
NZM2-XAD250
104555
NZM3-XAD630
107206
NZM2-4-XAD250
138388
NZM3-4-XAD630
138389
NZM2-XKR4
281666
NZM3-XKR13
281668
1off
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Conditions of Acceptability
Suitable for
Max. Voltage Rating
Degree of Protection
Product Standards
Part no. and part no. suffix include parts for one switch side
at top or bottom (for NZM3 top only.
Required with component adapter and switch withconnection on rear
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
Specially designed for NA
Suitable for
NZM2-4-XKR4
118907
Current Limiting CB
Max. Voltage Rating
Degree of Protection
UL508A;
CSA-C22.2 No. 14; IEC 60439-1;
CE marking
E300273
NMTR, NMTR7
236217
3211-37
UL Listed, CSA certified
Refer to approbation report
Feeder circuits
600 V AC
Feeder circuits
UL 489; CSA-C22.2
N o.5-09;IEC 60947-2;
CE marking
E31593
DIVA
022086
1432-01
UL Listed, CSA certified
Yes
Feeder circuits, branch
circuits
Yes
480Y/277 V
IEC: IP20; UL/CSA Type:
NZM3-4-XKR13
119020
133
1.6
Circuit-breakers, switch-disconnectors
Remote operators
1 NZM...-XR
For use with
Rated control
voltage
Us
V
Remote operators
For remote switching of circuit-breakers and switch-disconnectc
ON and OFF switching and resetting by means of two-wire or
three-wire control.
Closing delay 110170 ms, opening delay 110170 ms
110-130 V 50/60 Hz
NZM2(-4)
N (S)2(-4)
208-240 V 50/60 Hz
380-440 V 50/60 Hz
24-30 V DC
110-130 V DC
220-250 V DC
Closing delay 60-100 ms, opening delay 300-3000 ms
Can be svnchronized
NZM2(-4)
110-130 V 50/60 Hz
N(S)2(-4)
208-240 V 50/60 Hz
380-440 V 50/60 Hz
24-30 V DC
48-60 V DC
110-130 V DC
220-250 V DC
NZM3(-4)
N(S)3(-4)
110-130 V 50/60 Hz
208-240 V 50/60 Hz
380-440 V 50/60 Hz
24-30 V DC
48-60 V DC
110-130 V DC
220-250 V DC
NZM4(-4)
N(S)4(-4)
110-130 V 50/60 Hz
208-240 V 50/60 Hz
380-440 V 50/60 Hz
24-30 V DC
48-60 V DC
110-130 V DC
220-250 V DC
Part no.
Article no. when
ordered separately
Std. pack
Notes
1off
NZM2-XR110-130AC
259830
NZM2-XR208-240AC
259832
NZM2-XR380-440AC
259834
NZM2-XR24-30DC
259836
NZM2-XR48-60DC
259838
NZM2-XR110-130DC
259840
NZM2-XR220-250DC
259842
NZM3-XR110-130AC
259848
NZM3-XR208-240AC
259850
NZM3-XR380-440AC
259852
NZM3-XR24-30DC
259854
NZM3-XR48-60DC
259856
NZM3-XR110-130DC
259858
NZM3-XR220-250DC
259860
NZM4-XR110-130AC
266684
NZM4-XR208-240AC
266685
NZM4-XR380-440AC
266686
NZM4-XR24-30DC
266691
NZM4-XR48-60DC
266692
NZM4-XR110-130DC
266693
NZM4-XR220-250DC
266694
1off
Notes
Two-andthree-wire control, circuit diagram Engineering, Page 1753
134
Price
See price
list
Circuit-breakers, switch-disconnectors
1.6
Remote operators
Part no.
Article no. when
ordered separately
Price
See price
list
Std. pack
Notes
NZM2-4
N2-4
NZM3-4
N3-4
NZM2-XAVPR
266677
NZM3-XAVPR
266678
1off
NZM2(-4)
N(S)2(-4)
NZM2-XRDPL
137305
1off
NZM2-XR
NZM3-XR
NZM4-XR
RTR-NZM10
034825
1off
Electrical remote switching and manual tripping (push to trip) are still
possible.
1off
Setting range
Overload
releases
Short-circuit
releases
Iu
A
Ir
A
Ii
A
Price
See price
list
Std. pack
B = box terminals
S = screw terminals
I
Circuit-breakers with earth-fault release, 3 pole
For apparatus with power electronics,
such as power inverters and frequency inverters
AC/DC sensitive according to core-balance principle in range of 0100 kHz residual-current frequency
Not UL/CSA approved.
Suitable for use in three-phase systems.
Rated operating voltage: 400 V (50/60 Hy
Rated fault current log0.03 A
Internal power supply U50400 V
Turnkey combination of current-limiting circuit-breaker and residual-current device.
Adjusting buttons can be sealed.
3 pole
125
100-125
750...1250
NZMH2-A125-FIA30
129710
160
125-160
960...1600
NZMH2-A160-FIA30
112627
200
160-200
1200...2000
NZMH2-A200-FIA30
112628
250
200-250
1500...2500
NZMH2-A250-FIA30
112629
125
100-125
750...1250
NZMH2-A125-FIA30-BT
129711
160
125-160
960...1600
NZMH2-A160-FIA30-BT
116304
200
160-200
1200...2000
NZMH2-A200-FIA30-BT
116305
250
200-250
1500...2500
NZMH2-A250-FIA30-BT
116306
1off
135
Circuit-breakers, switch-disconnectors
1.6
1 NZM...XFI...
For use
with
Number of
conductors
Part no.
Article no.
Price
See price
list
Std. pack
Notes
NZM1-XF130R
104603
NZM1-4-XF130R
104606
NZM1-XF1300R
104604
NZM1-4-XF1300R
104607
NZM1-XFIR
104605
NZM1-4-XFIR
104608
1off
NZM1-XF130U
104609
NZM1-4-XF130U
104612
NZM1-XF1300U
104610
NZM1-4-XF1300U
104613
NZM1-XFIU
104611
NZM1-4-XFIU
104614
1off
4 pole
+NZM2-4-XF130
292343
1off
4 pole
+NZM2-4-XFI
292344
Earth-fault release
To IEC/EN 60947-2
Not UL/CSA approved
Suitable for use in three- and single-phase systems
Pulse-current sensitive according to core-balance principle
For 3 and 4 pole NZM1}-4) circuit-breakers and N1}-4)
switch-disconnectors, dependant on mains power U200 ...415 V 50/60 Hz
Mounting on right side up to In=160 A at Icu=50 kA
Rated fault current
In=0.03A
NZM1
N(S)1
3 pole
NZM1-4
N1-4
4 pole
NZM1
N(S)1
3 pole
NZM1-4
N1-4
4 pole
NZM1
N(S)1
3 pole
NZM1-4
N1-4
4 pole
NZM1
N(S)1
3 pole
NZM1-4
N1-4
4 pole
NZM1
N(S)1
3 pole
NZM1-4
N1-4
4 pole
NZM1
N(S)1
3 pole
NZM1-4
N1-4
4 pole
NZM2-4
N2-4
NZM2-4
N2-4
136
NZM2-4
N2-4
NZM2-4
N2-4
4 pole
+NZM2-4-XFIA
292346
4 pole
+NZM2-4-XFIA30
292345
1off
Observeresponsethreshold dependence
on frequency!
See "Frequency response" characteristic
curve.
Adjusting buttons can be sealed.
Circuit-breakers, switch-disconnectors
Earth-fault release, residual-current relay
1.6
NZM4
NS4
NZM4-4
+NZM4-XT
266721
+NZM4-4-XT
266722
Price
See price
list
1 off
1 off
Part no.
Article no.
Description
Price
See price
list
Rated current
Enerav Motor
In
In
A
A
Residual-current relays
Pulsed current sensitive
Rated control voltage: Us=230 V AC (50/60 Hz)
Integrated auxiliary contact (1 C/0)
Ring-type transformer must also be ordered.
Not UL/CSA approved
Rated fault current IN0.03 A
PFR-003
285555
PFR-03
285556
PFR-5
285557
PFR-5-110AC
116963
Internal diameter: 20 mm
50
50
PFR-W-20
285558
Internal diameter: 30 mm
150
100
PFR-W-30
285559
Internal diameter: 35 mm
150
100
PFR-W-35
285600
Internal diameter: 70 mm
400
200
PFR-W-70
285601
600
250
PFR-W-105
285602
1200
630
PFR-W-140
285603
1800
800
PFR-W-210
285604
PFR-W-35
PFR-WMA-35
286001
PFR-W-70
PFR-WMA-70
286002
PFR-W-105
PFR-WMA-105
286003
PFR-W-140
PFR-WMA-140
286004
PFR-W-210
PFR-WMA-210
286005
PFR-WC
286006
1off
1off
Ring-type transformer
Rated operating voltage: 690 V (50/60 Hz)
Not UL/CSA approved
Includes screwfixing
Alternative: fixing clip for DIN
mounting rail
Note on engineering:
The current transformer
diameter must be selected 1.5
times largerthanthe envelope
diameterofthepassedthrough
conductor
Magnetic shielding
Not UL/CSA approved
1off
1off
1 set2 off
Mounting clip
137
Circuit-breakers, switch-disconnectors
1.6
1 Description
Components for energy metering and communication
PROFIBUS-DP
Modbus RTU
CAN
NZM
XDMI612
NZM
NZM
EU5C-SWD
XSWD-704
PC
XMC-DISP
XPC-Soft
XMC-S0
CurveSelect
PKE
Overview
Forthecompactcircuit-breakers NZM
Eaton supplies the following energy
measurement and communication
components:
NZM-XPC-Soft: Diagnostics
software
CurveSelect: Software for viewing
characteristic curves
NZM-XMC-S0: Energy measuring
module
NZM-XMC-MB: Measuring and
communication module
NZM-XSWD-704: Communication
interface for SmartWire-Darwin
with SO input for energy data
NZM-XDM1612: Data management
interface with field bus connection
for PRDFIBUS-DP and bus
diagnostics software
CurveSelect
Thefree characteristic curve program
Moeller CurveSelect allows a settingsspecific representation of the tripping
characteristics of several protective
devices with the same time and
current scales.
This clearly simplifies an assessment
of the interaction of Eaton's circuitbreakers NZM and IZM, motorprotective circuit-breakers PKZ,
overload relays ZB, miniature circuitbreakers, and LV h.c. fuses.
Available for free download from
www.moeller.net:
Products&Solutions>Power
Distribution>Switching and
Protecting Power > CurveSelect:
Characteristics program for shortcircuit- and overload protection.
XPC-Soft
Circuit-breakers NZM with electronic
trip block provide all required
diagnostics data directlytothe USB or
COM interface of a connected PC
through a built-in interface.
On overload or short-circuit, the NZM
instantly switches off the system and,
if a PC is connected, documents the
events complete with date and time.
With the software XPC-Soft, users can
viewthe history and analyze possible
causes. The software can also output
power consumption trend graphs as
MS Excel table
138
XMC-MB
Circuit-breakers, switch-disconnectors
Diagnostics, communication
1.6
1
Description
Part no.
Article no.
Std. pack
Notes
NZM-XPC-KIT
265631
1 off
EASY-USB-CAB
107926
1 off
NZM-XDMI612
260217
1 off
NZM-XDMI-DPV1
270333
1 off
EASY400-POW
212319
1 off
M22-TA
226161
1 off
Price
See price
list
ESC
ALT
OK
Pow er
Telescopic adapter
For DMI module
For equalization of the mounting depth when rear mounted in CI-K... enclosures
and cabinets
W ith 35 mm top-hat rail IEC/EN 60715, adjustable from
75115 mm. Screw and snap fitting.
Product Standards
UL File No.
UL CCN
CSA File No.
CSA Class No.
NA Certification
139
Circuit-breakers, switch-disconnectors
1.6
Diagnostics, communication
1 NZM, easy
Description
Part no.
Article no.
Price
See price list
Std. pack
Notes
FDT-NAVIGATOR
281623
NZM-XPC-DTM
281624
1 off
140
NZM-XSWD-704
135530
1 off
A connection cable to
the circuit-breaker and
auxiliary contacts NZM
is included as standard.
Circuit-breakers, switch-disconnectors
1.6
Diagnostics, communication
NZM...-XMC
Number of
conductors
Part no.
Article no.
Price
See price
list
NZM2<
=300A
NZM2-XMC-S0
129839
1 off
NZM2<
=500A
NZM3-XMC-S0
129960
1 off
NZM2<
=300A
NZM2-4-XMC-S0
129963
1 off
NZM3<
=500A
NZM3-4-XMC-S0
129964
1 off
Description
Std.
pack
Notes
3 pole
4 pole
When mounting,
observe the
minimum
clearancesto circuitbreaker NZM.
The module can
befittei on the input
or output side.
4 pole
NZM2<
=300A
NZM2-XMC-S0
129839
1 off
NZM2<
=500A
NZM3-XMC-S0
129960
1 off
NZM2<
=300A
NZM2-4-XMC-S0
129963
1 off
NZM3<
=500A
NZM3-4-XMC-S0
129964
1 off
NZM...XMC-MB
NZM-XMC-DISP
129967
1 off
NZM-XMC-AC
129968
1 off
MODBUS interface
1 off
Analog outputfor
4-20 mA pointer-type
instruments
+NZM-XMC-MB
135524
+NZM-XMC-1A0
135525
2 relay outputs
(changeover contact)
+NZM-XMC-2D0-R
135526
1 off
4 relay outputs
(changeover contact)
+NZM-XMC-4D0-R
135527
1 off
+NZM-XMC-4DI-4D0
135528
1 off
When mounting,
observe the
minimum
clearancesto circuitbreaker NZM.
The module can
befitted on the input
or output side.
Power supply
Power supply 230 V AC
3/4 pole
1 off
141
Circuit-breakers, switch-disconnectors
1.6
Insulated enclosures
NZM-XCI
1
Degree of
protection
Max. rated
uninterrupted
current
Part no.
Article no. when
ordered separately
Price
See price
list
Std. pack
IP65
63A
PN1, N(S)1
NZM1-XCIK5-TVD
271521
1 of
IP65
63A
NZM1-XCI23-TVD
271522
1 of
IP64
125A
NZM1(-4), PN1(-4),
N(S)1(-4)
NZM1-XCI43-TVD
271523
1 of
IP64
160A
NZM1(-4), PN1(-4),
N(S)1(-4)
NZM1-XCI43/2-TVD
104645
1 of
IP64
200A
NZM2(-4), PN2(-4),
N(S)2(-4)
NZM2-XCI43-TVD
271524
1 of
IP64
250A
NZM2(-4), PN2(-4),
N(S)2(-4)
NZM2-XCI45-TVD
280418
1 of
IP64
400A
NZM3(-4), PN3(-4),
N(S)3(-4)
NZM3-XCI48-TVD
271525
1 of
IP65
63A
PN1, N(S)1
NZM1-XCIK5-TVDVR
271526
1 of
IP65
63A
NZM1-XCI23-TVDVR
271527
1 of
IP64
125A
NZM1(-4), PN1(-4),
N(S)1(-4)
NZM1-XCI43-TVDVR
271528
1 of
IP64
160A
NZM1(-4), PN1(-4),
N(S)1(-4)
NZM1-XCI43/2-TVDVR
104646
1 of
IP64
200A
NZM2(-4), PN2(-4),
N(S)2(-4)
NZM2-XCI43-TVDVR
271529
1 of
IP64
250A
NZM2(-4), PN2(-4),
N(S)2(-4)
NZM2-XCI45-TVDVR
279356
1 of
IP64
400A
NZM3(-4), PN3(-4),
N(S)3(-4)
NZM3-XCI48-TVDVR
271530
1 of
Insulated enclosures
With door coupling rotary handle
Complete includes all necessaryfunctional parts
Not UL/CSA approved
Standard, black/grey
Lockable in 0 position on handle with up to 3
padlocks. Additionally with cover interlock.
142
Part no.
Article no. when
ordered separately
Price
See price
list
Std. pack
K10/1
093827
10 of
63
K25/1
096200
10 of
100
K50/1
098573
10 of
160
Stranded, 1 x (1695)
K95/1N/BR
012336
10 of
250
Stranded, 1 x (351501,2x(1670)
K150/1/BR
014709
10 of
400
K240/1/BR
017082
10 of
630
K2X240/1/BR
019455
10 of
Circuit-breakers, switch-disconnectors
Insulated enclosures
1.6
NZM-XCI
Basic
enclosure
Notes
CI-K5-160-M
K10/1, K25/1
C123-150
K10/1, K25/1
C143-150
Enclosures for separate mounting with top and bottom cable entry, suitable
for installation of
circuit-breakers and switch-disconnectors.
Include fixing straps for wall mounting.
Short-circuit resistance at 415 V 50/60 Hz up to 10 kA.
C143-200
C143-200
C145-200
C148-250
CI-K5-160-M
K10/1, K25/1
C123-150
K10/1, K25/1
C143-150
C143-200
C143-200
C145-200
C148-250
143
Circuit-breakers, switch-disconnectors
1.7
1 NZM,FAZ-B(C),PKZ
Engineering
1
2
Incoming circuitbreaker
Outgoing circuitbreaker
Selectivity 415 V AC
between circuit-breakers enables separate shut-down of faulty system sections.
Selectivity (discrimination) exists between incoming breaker 1 and outgoing breaker 2 if,
only outgoing breaker 2 trips at position 2 during a short-circuit.
System sections 3 and 4 continue to be operational.
Incoming circuit-breaker (S1)
PKZMO...
PKZ2/ZM-...
PKZM4...
Notes
144
Icu[kA]
In[A]
Icu(415V)
In
[A]
[kA]
1
15
2
15
3
15
4
15
6
15
10
15
13
15
16
15
20
15
25
15
32
15
40
15
50
15
63
15
0.16
100
0.25
100
0.4
100
0.63
100
1
100
1.6
100
2.5
100
4
100
6.3
100
10
100
12
50
16
50
20
50
25
50
32
50
0.6
100
1.0
100
1.6
100
2.4
100
4
100
6
100
10
100
16
100
25
30
32
30
40
30
16
100
25
100
32
50
40
50
50
50
58
50
63
50
T:total selectivity
NZM...1-A...
25(36)(50)(100)
63
20-40 50
80
100
125
160
NZM...2-A...
25(36)(50)(150)
20-40 50
63
80
100
125
160
200
250
300
Selectivity threshold Is [kA] for selectivity between S2 and S1, overload and short-circuit release set to
max. value
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
Circuit-breakers, switch-disconnectors
1.7
NZM
T
T
T
T
T
T
10
10
10
10
10
8
7
6
6
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
10
8
4
3
2
2
2
5
5
4
3
2.5
2.5
2
T
T
T
T
T
T
10
10
10
10
10
10
10
10
10
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
5
4
3
3
2.5
6
3.3
3
3
3
2.5
2.5
T
T
T
T
T
T
10
10
10
10
10
10
10
10
10
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
10
5
4
3
3
2
5
5
4
3
2.5
2.5
2
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
6
4
3
3
3
10
6
5
5
5
4
4
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
9
5
4
4
4
13
10
7
7
7
6
6
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
30
10
8
8
30
15
12
12
10
10
10
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
5
4
3
3
2.5
6
3.3
3
3
3
2.5
2.5
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
13
7
5
3.5
3.5
16
10
8
8
8
6.5
6.5
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
20
15
15
45
25
18
18
18
15
15
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
5
4
3
3
2.5
6
3.3
3
3
3
2.5
2.5
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
13
7
5
3.5
3.5
16
10
8
8
8
6.5
6.5
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
20
15
15
45
25
18
18
18
15
15
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
45
25
18
18
18
15
15
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
42
30
30
30
25
25
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
45
45
45
40
40
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
45
25
18
18
18
15
15
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
42
30
30
30
25
25
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
45
45
45
40
40
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
145
Circuit-breakers, switch-disconnectors
1.7
1 NZM
1
2
Incoming circuitbreaker
Outgoing circuitbreaker
Selectivity 415 V AC
between circuit-breakers enables separate shut-down of faulty system sections.
Selectivity (discrimination) exists between incoming breaker 1 and outgoing breaker 2 if,
only outgoing breaker 2 trips at position 2 during a short-circuit.
System sections 3 and 4 continue to be operational.
Incoming circuit-breaker (S1)
NZM...2-A...
NZM...1-M...
NZM...2-M...
NZM...2-VE...
NZM...2-ME...
NZM...3-AE...
NZM3-VE...
NZM...3-ME...
NZM...4-AE...
NZM4-VE
NZM...4-ME..
Notes
146
Icu[kA]
In[A]
In
Icu(415V)
[A]
[kA]
20-40
25-100
50
25-100
63
25-100
80
25-100
100
25-100
125
25-100
160
25-100
20-40
25-150
50
25-150
63
25-150
80
25-150
100
25-150
125
25-150
160
25-150
200
25-150
250
25-150
300
25-150
40
25-150
50
25-150
63
25-150
80
25-150
100
25-150
20-12
25-150
160
25-150
200
25-150
100
25-150
160
50-150
250
50-150
90
50-150
140
50-150
220
50-150
250
50-150
320
50-150
400
50-150
500
50-150
630
50-150
250
50-150
400
50-150
630
50-150
220
50-150
350
50-150
450
50-150
630
50-150
800
50-150
1000
50-85
1250
50-85
1600
50-85
630
50-85
800
50-85
1000
50-85
1250
50-85
1600
50-85
550
50-85
875
50-85
1400
50-85
T:total selectivity
NZM...2-A...
NZM...1-A...
25(36)(50)(100)
25(36)(50)(150)
63
80
100 125 160 20-40 50
63
80
100 125 160 200
20-40 50
Prospective short-circuit current (kA). Set the overload and short-circuit release of the incoming
circuit-breaker to the max. value.
0.8
1.5
0.5
0.8
1.5 1.5
1.5
2
0.7
1.5
0.6
2
0.8
1.5
0.8
1.5 1.5
1.5
0.6
1.5
2
0.8
1.5
1.5 1.5
1.5
1.5
1.5
1.5 1.5
1.5
1.5
1.5
0.5
1.6
0.8
1
0.5
0.6
1
1.2
0.6
0.8
1
1.6
0.8
1
0.6
1
1.2
0.6
0.8
1
1.6
0.8
1
1
1.2
0.8
1
1.6
1
1.2
1.6
1.2
1.6
1.6
0.8
1
1.2
1
1.6
1.2
1
1.6
1.2
1.6
1.2
1.6
1.2
1.6
250
300
3
3
3
3
3
3
3
2
2
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
2
2
2
2
2
2
2
2
2
2
2
2
Circuit-breakers, switch-disconnectors
1.7
NZM
NZM...3-A...
36(50)(150)
250
320 400
500
NZM...3-AE...
50(150)
250 400 630
NZM...3-VE...
50(150)
250 400 630
NZM...4-AE...
NZM...4-VE...
50(150)
50(150)
630 800 1000 1250 1600 630 800 1000 1250 1600
Prospective short-circuit current (kA). Set the overload and short-circuit release of the incoming
circuit-breaker to the max. value.
2
2
2
1
1
1
5
5
5
5
5
5
5
2
2
2
2
2
2
2
2
2
1.2
7.5
7.5
6
6
6
6
6
4
4
4
4
4
4
4
4
4
4
4
4
2
2
2
3
3
3
3
3
3
3
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
6
6
5
5
5
5
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7
7
7
7
7
7
7
7
7
7
7
6
6
6
6
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7.5
7.5
6
6
6
6
6
6
6
6
6
6
6
5
6
6
6
6
6
6
6
6
6
6
6
20
20
15
15
15
15
15
15
15
15
15
15
15
10
10
10
10
15
15
15
15
15
7
7
7
7
7
7
7
7
7
5
5
3.5
3.5
20
20
15
15
15
15
15
15
15
15
15
15
15
10
10
10
10
15
15
15
15
15
10
10
10
10
10
10
10
10
10
7.5
7.5
7.5
4
4
4
4
12.5
12.5
11
11
11
11
11
11
11
11
11
11
11
10
11
11
11
11
11
7
7
7
7
5
5
5
25
25
20
20
20
20
20
20
20
20
20
20
20
15
15
15
15
20
20
20
20
20
10
10
10
8
8
8
10
10
10
10
10
10
10
25
25
20
20
20
20
20
20
20
20
20
20
20
15
15
15
15
20
20
20
20
20
12
12
12
11
11
11
12
12
12
12
12
12
12
12
12
12
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
10
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
15
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
20
20
20
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
20
20
20
20
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
10
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
15
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
20
20
20
20
20
20
20
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
T/80
20
20
20
20
20
20
20
20
20
20
147
1.7
Circuit-breakers, switch-disconnectors
Auxiliary contacts, trip-indicating auxiliary contacts
NZM...1(-4)-...20
NZM...1(-4)-...25 160
NZM...2(-4)-...20 300
NZM...3(-4)-...250 630
NZM...4(-4)-...630 1600
Minimum protected
cross-section mm2 copper
6
10
10
16
95
Backup protection
between incoming circuit-breaker NZM(N)(H) and outgoing circuit-breaker NZMB(N)(H)
Incoming circuit-breaker
Icc
In
Icu(415 V)
NZM...
a
Outgoing circuit-breaker
Icu(415 V) In
NZMB1 25 kA
Up to 160 A
NZMC1 36 kA
Up to 160 A
NZM... NZMN1 50 kA
Up to 160 A
b
NZMH1 100 kA Up to 160 A
NZMB2 25 kA
Up to 300 A
NZMC2 36 kA
Up to 300 A
NZMN2 50 kA
Up to 300 A
NZMH2 150 kA Up to 300 A
NZMC3 36 kA
Up to 500 A
NZMN3 50 kA
Up to 630 A
NZMH3 150 kA Up to 630 A
NZM1
Up to 160 A
25 kA 36 kA
25
25
36
36
36
36
50 kA
NZM2
Up to 250 A
100 kA 25 kA 36 kA
50 kA 150 kA 36 kA
50 kA
150 kA
50
50
50
50
50
50
100
100
100
100
100
100
100
50
50
50
50
50
50
50
50
50
50
50
50
50
50
100
100
100
100
150
150
150
150
150
150
150
25
25
The table shows which current-limiting circuitbreakers NZMN(H) provide reliable protection at
network locations with high short-circuit ratings
in combination with NZMB(C)(N).
36
36
36
36
148
PLSM-B(C)...(/...)
0.5 10
13 32
40 63
25 kA
25 kA
20 kA
100
100
100
100
150
150
150
150
36
36
36
36
FAZ...
PLSM...
NZM3
Up to 500 A Up to 630 A
NZMC(N)(H)1-A...
30 kA
20 kA
15 kA
30 kA
20 kA
15 kA
NZMN(H)2-A...
50 kA
30 kA
20 kA
50 kA
30 kA
20 kA
Circuit-breakers, switch-disconnectors
1.7
Direction of blow-out
NZM1
NZMB(C)2-A... 250
(P)N2(-4)-...
NZMN(H)2...
NZM...2-4..
NZM3
NZM4
Top,
front
X
X
X
X
X
X
X
Bottom,
rear
X
X
X
Minimum clearances
30
60
1)
NZM2
5
5
201)
351)
5
5
30
60
NZM3
15
15
50
NZM4
1001)
d
690V
0
35
60
0
1000 V
35
60
200
1000 V
35
60
0
For pressing the cable lugs a press tool K22, HK60/22 or EK22
from Klauke with the following press inserts is required:
R22/95 for 95 mm2
R22/120 for 120 mm2
R22/150 for 150 mm2
R22/185 for 185 mm2
R22/240 for 240 mm2
Cable lug
KS95-NZM7
KS120-NZM7
KS150-NZM7
NZM2-XKS185
NZM3-XKS185
NZM3-XKS240
NZM2
NZM2
NZM2
NZM2
NZM3NZM4
NZM3NZM4
Nominal cross
section
mm2
95
120
150
185
185
240
Terminal bolt
Dimensions in mm
a
53+2
56+2
61+2
651.5
65
72
M8
M8
M8
M8
M10
M10
b
230.5
230.5
230.5
221
24.5
31
c
180.2
19.50.2
210.2
240.3
24
26
d
101
101
101
9+1
-0.5
11.5
11.5
e
19
19
19
+2.5
19-0.5
18
19
f
8.5
8.5
8.5
8.5+0.05
-0.5
10.5
10.5
g
25
26
30
302
30
35
h
13.5
15
16.5
190.4
19
21
i
4.4
4.4
4.4
7
0.70.8
5.00.8
149
Circuit-breakers, switch-disconnectors
1.7
Engineering
Front cut-outs
Cut-out a
Rocker lever
Cut-outb
Rotary handle, remote operator
a
b
c
d
NZM1
NZM2
NZM3
NZM4
Cut-out
c
mm
68
103
120.5
138
e
mm
68
103
120.5
138
d
mm
68
103
120.5
138
Cut-out
f
mm
68
103
120.5
138
e
mm
68
103
120.5
138
f
mm
68
103
120.5
138
NZM 1, 2, 3
+
L1L2L3
HIN
+
HIN
L1L2L3
HIV
+
HIA
L1L2L3
L1L2L3
HIV
HIV
0 I Switch-on
0 I Switch-off
+ I Trip
HIA
L1L2L3
L1L2L3
HIV
HIV
L1L2L3
+
+
L1L2L3
HIN
150
HIV
L1L2L3
Notes
NZM 1, 2, 3
L1L2L3
L1L2L3
L1L2L3
HIA
Contact closed
Contact opened
If early-make contacts are required in combination with shunt orundervoltage releases, please select the combination type in section
Releases
Circuit-breakers, switch-disconnectors
1.7
NZM, NZM...-XBZ-...
OFF
OFF
ON
ON/TRIP
ON
ON/TRIP
OFF
OFF
OFF
ON
ON
ON
x4P
3/4 pole
3/4 pole
3/4 pole
3/4 pole
NZM-1
X3P
mm
135
135
90
50
ON
ON/TRIP
OFF
ON/TRIP
OFF
OFF
ON/TRIP
ON
ON
ON
ON/TRIP
D
OFF
ON
ON/TRIP
x4P
x3P
x3P
ON
ON
ON/TRIP
ON
ON
ON/TRIP
ON/TRIP
ON
ON/TRIP
ON/TRIP
X4P
mm
85
85
35
15
Right switch
NZM-3
X3P
mm
135
135
85
25
X4P
mm
90
90
40
NZM-4
X3P
mm
125
125
80
15
X3P
mm
80
80
45
NZM-2
X3P
mm
495
495
450
380
X4P
mm
460
460
410
340
NZM-3
X3P
mm
510
510
460
400
X4P
mm
465
465
415
375
NZM-4
X3P
mm
475
475
460
390
X3P
mm
405
405
390
320
NZM-2
X3P
mm
895
895
850
730
X4P
mm
860
860
810
700
NZM-3
X3P
mm
910
910
860
800
X4P
mm
865
865
815
775
NZM-4
X3P
mm
865
865
860
790
X3P
mm
795
795
790
720
X4P
mm
105
105
75
35
NZM-2
X3P
mm
120
120
75
40
NZM-1
X3P
mm
510
510
460
400
X4P
mm
480
480
430
370
NZM-1
X3P
mm
910
910
820
750
X4P
mm
880
880
790
720
151
1.7
NZM...-XMVR(L)
Mechanical interlock XMVR
NZM...-XMVR (mounted side-by-side)
Max. switch spacing
Right switch
NZM3
NZM2
X 4p
X 3p
Left switch
NZM2
3/4 pole
NZM3
3/4 pole
NZM4
3/4 pole
mm
130
NZM4
X 3p
mm
95
X 4p
mm
95
135
mm
50
90
400
NZM4
3/4 pole
x4P
x3P
X 3p = m a x . s w itc h s p a c in g 3 p o le
X 4p = m a x . s w itc h s p a c in g 4 p o le
Y
Switch at bottom
NZM2
3/4 pole
NZM3
3/4 pole
NZM4
3/4 pole
mm
220
NZM4
3/4 pole
Y
mm
225
220
Y
mm
230
230
Circuit-breakers, switch-disconnectors
50
150
150
400
600
1200
1800
2010 CA08103002Z-EN
152
Diameter
Transformer part
no. PFR-W-
d1
50
100
100
200
250
630
800
www.eaton.com
20
30
35
70
105
140
210
Maximum
conductor circumference (mm)
d2
13
20
23
47
70
93
140
d2
d1 f 1.5 x d2
X 4p
mm
385
365
X 3p
mm
155
120
NZM4
X 3p
mm
460
420
X 4p
mm
85
50
X 4p
mm
390
350
Circuit-breakers, switch-disconnectors
Side wall operator, 2/3-wire control remote operator
1.7
NZM-XS(R)M, NZM...XRD
Side wall operator, 2/3-wire control remote operator
Additional terminal arrangement for side wall operator with mounting bracket.
NZM1-XS(R)M-..., NZM2-XS(R)M-...
Additional terminals K25, K50, K95, K150
Actuation:
3 p o le
For operation on the right
1
4 p o le
For operation on the right
MII
MI
M o u n tin g a r e a s
V a r ia tio n o p tio n s
Maximum number of additional
terminals
MI
K25
K50
K95
K150
MI
V1
2x
V2
2x
MI
MII
V3
1x
MII
V1
1x
V4
1x
MII
V2
1x
Example : In mounting area MI, variation option 1 allows the K25 additional terminal to be mounted twice.
T h r e e - w i r e c o n tr o l
T e r m i n a l 70/71:
NZM-XR: Contact loading according to technical data
NZM2-XRD: Full current flows though the contact during make and break!
RMQ series contact elements can be used fo
r the remote operators.NZM2(3.4)-XR(D)...
L1
(L1+)
70
H1
71 72
75
74
N
(L1, L2)
T w o - w i r e c o n tr o l
L1
(L1+)
T e r m i n a l 75:
NZM-XR: Operational readiness signal when cover closed and not locked.
NZM2-XRD: Operational readiness signal when sliding switch set to Auto.
Sliding switch with three positions: Manual/Auto/Locked for reliable differentiation of
operating positions.
AC-15: 400 V; 2 A
DC-13: 220 V; 0.2 A
0 I
H1
70
71 72
75
74
N
(L1, L2)
H1
HIA
70
71 72
75
74
N
(L1, L2)
Switching cycle:
N Z M 2- X R D
170 ms
OFF
ON
N Z M 2- X R
F 170 ms
r
ON
OFF
OFF
ON
60 ms
OFF
ON
t> 3 s
r
ON
60 ms
OFF
OFF
ON
NZM3-XR
80 ms
OFF
ON
t> 3 s
r
ON
80 ms
OFF
OFF
ON
NZM4-XR
100 ms
OFF
ON
t> 3 s
r
ON
OFF
100 ms
OFF
ON
153
Circuit-breakers, switch-disconnectors
1.7
NZM1, NZM2
NZM1(-4)-A...
2000
1000
800
(10 min) 600
400
2000
1000
800
(10 min) 600
400
200
100
80
(1 min) 60
40
Tolerance t r [s]
200
100
80
(1 min) 60
40
20
20
10
8
6
4
10
8
6
4
2
Setting range
1
0.8
0.6
0.4
Ii = 6
0.2
10 x I n
0.02
0.02
0.01
0.008
0.006
0.004
0.01
0.008
0.006
0.004
0.002
0.002
2
5 6 7 8 9 10
15
Ii = 8
0.2
0.1
0.08
0.06
0.04
Setting range
1
0.8
0.6
0.4
0.1
0.08
0.06
0.04
0.001
NZM1-M...
Tolerance tr [s]
2.5 h 8000
6000
4000
20
30
0.001
40 50 60 70 80 100
5 6 7 8 9 10
14x I n
15
20
30
40 50 60 70 80 100
x Ir
x Ir
2.5 h 8000
6000
4000
NZM2(-4)-A...
Tripping time [s]
2000
2.5 h 8000
6000
4000
2000
1000
800
(10 min) 600
400
1000
800
(10 min) 600
400
200
100
80
(1 min) 60
40
Tolerance t r [s]
200
100
80
(1 min) 60
40
20
10
8
6
4
20
10
8
6
4
2
2
Setting range
1
0.8
0.6
0.4
Ii = 6
0.2
10 x I n
0.02
0.02
0.01
0.008
0.006
0.004
0.01
0.008
0.006
0.004
0.002
0.002
2
5 6 7 8 9 10
15
Ii = 8
0.2
0.1
0.08
0.06
0.04
Setting range
1
0.8
0.6
0.4
0.1
0.08
0.06
0.04
0.001
NZM2-M...
Tolerance tr [s]
20
30
40 50 60 70 80 100
0.001
5 6 7 8 9 10
14x In
15
20
30
40 50 60 70 80 100
x Ir
Notes
154
With the free CurveSelect software you can quickly and easily create detailed representations of individual settings:
www.moeller.net, Products & Solutions>Power Distribution>Switching and Protecting Power Distribution>CurveSelect: Characteristics program.
NZM1-4 December 2011 www.eaton.com.cn/electrical
x Ir
Circuit-breakers, switch-disconnectors
1.7
NZM2, NZM3
2000
2.5 h 8000
6000
4000
2.5 h 8000
6000
4000
2000
1000
800
(10 min) 600
400
1000
800
(10 min) 600
400
200
200
100
80
(1 min) 60
40
(1 min)
10
8
6
4
tr [s]
20
17
14
10
8
6
4
20
tsd [ms]
1000
750
500
5 6 7 8 9 10
0.02
x Ir
0.01
0.008
0.006
0.004
0.002
0.002
3
5 6 7 8 9 10
5 6
10 12 14 x I r
5 6 7 8 9 10
0.02
Ii = 12 x I n
0.01
0.008
0.006
0.004
0.001
Ii =
0.1
0.08
0.06
0.04
20
4
0.2
100
60
3
10
8
6
4
tr [s]
20
17
14
10
8
6
4
1
0.8
0.6
0.4
300
200
0.2
Isd = 2
100
80
60
40
20
1
0.8
0.6
0.4
0.1
0.08
0.06
0.04
NZM2-ME...
Characteristics for I r = 1,0 x I n
15
20
30
0.001
40 50 60 70 80 100
15
20
30
40 50 60 70 80 100
x Ir
x Ir
(10 min)
NZM3(-4)-A...
Characteristics for I r = 1,0 x I n
2000
1000
800
600
400
NZM3(-4)-AE...
2000
1000
800
(10 min) 600
400
200
200
Tolerance tr [s]
(1 min)
2.5 h 8000
6000
4000
2 .5 h 8000
6000
4000
100
80
60
40
100
80
(1 min) 60
40
20
20
10
8
6
4
10
8
6
4
2
Setting range
1
0.8
0.6
0.4
Ii = 6
0.2
1
0.8
0.6
0.4
10 x I n
0.2
0.1
0.08
0.06
0.04
0.1
0.08
0.06
0.04
0.02
Ii =
2 2.5 3 3.5 4
5 6 7 8
Ii =
5 6 7 8 9 10
x In
630 A
6 7 8 9 11 x I n
250 A, 400 A
0.02
0.01
0.008
0.006
0.004
0.01
0.008
0.006
0.004
0.002
0.002
0.001
5 6 7 8 9 10
15
20
30
40 50 60 70 80 100
x Ir
Notes
0.001
15
20
30
40 50 60 70 80 100
x Ir
With the free CurveSelect software you can quickly and easily create detailed representations of individual settings:
www.moeller.net, Products & Solutions>Power Distribution>Switching and Protecting Power Distribution>CurveSelect: Characteristics program
NZM1-4 December 2011 www.eaton.com.cn/electrical
155
Circuit-breakers, switch-disconnectors
1.7
1 NZM3, NZM4
Systems, cable, selectivity and generator protection with NZM3
NZM3(-4)-VE...
Characteristics for I r = 1,0 x I n
2000
2.5 h 8000
6000
4000
2.5 h 8000
6000
4000
2000
1000
800
(10 min) 600
400
1000
800
(10 min) 600
400
200
200
100
80
(1 min) 60
40
(1 min)
10
8
6
4
tr [s]
20
17
14
10
8
6
4
20
Isd = 1.5
2.5 3 3.5 4
tsd [ms]
1000
750
500
300
200
x Ir
100
60
6 7
0.1
0.08
0.06
0.04
5 6 7 8 9 10 x I r
Isd =
0.01
0.008
0.006
0.004
Ii =
2 2.5 3 3.5 4
5 6 7 8
Ii =
5 6 7 8 9 11 x I n
5 6 7 8 9 10
0.002
10
8
6
4
tr [s]
20
17
14
10
8
6
4
1
0.8
0.6
0.4
=
I2t = constant
00
[m
Isd = 1.5
2 2.5 3 3.5 4
5 6 7
Isd =
5 6 7 8 910 x I r
x Ir
250 A, 400 A
0.02
630 A
0.01
0.008
0.006
0.004
Ii =
2 2.5 3 3.5 4
5 6 7 8
250 A, 400 A
0.002
Ii =
5 6 7 8 9 11 x I n
5 6 7 8 9 10
x In
0.001
1
s]
t sd
0.1
0.08
0.06
0.04
20
10
....
....
0.2
630 A
0.02
0.001
20
2
100
80
60
40
20
1
0.8
0.6
0.4
0.2
NZM3(-4)-VE...
Characteristics for I r = 1,0 x I n
15
20
30
40 50 60 70 80 100
630 A
250 A, 400 A
630 A
x In
250 A, 400 A
15
20
30
40 50 60 70 80 100
x Ir
2.5 h 8000
6000
4000
NZM3-ME...
Characteristics for I r = 1,0 x I n
2000
1000
800
(10 min) 600
400
200
100
80
(1 min) 60
40
10
8
6
4
tr [s]
20
17
14
10
8
6
4
20
1
0.8
0.6
0.4
0.2
Ii =
0.1
0.08
0.06
0.04
5 6
8 10 12 14 x I r
5 6 7 8 9 10
0.02
0.01
0.008
0.006
0.004
0.002
0.001
Notes
156
15
20
30
40 50 60 70 80 100
xI
r
With the free CurveSelect software you can quickly and easily create
detailed representations of individual settings:
www.moeller.net, Products & Solutions>Power Distribution>Switching and Protecting Power Distribution>CurveSelect: Characteristics program
x Ir
Circuit-breakers, switch-disconnectors
Construction size 4: tripping characteristics
1.7
NZM4
2000
2.5 h 8000
6000
4000
2.5 h 8000
6000
4000
2000
1000
800
(10 min) 600
400
1000
800
(10 min) 600
400
200
200
100
80
(1 min) 60
40
(1 min)
NZM4(-4)-VE(F)...
Characteristics for I r = 1,0 x I n
100
80
60
40
20
20
10
8
6
4
10
8
6
4
tr [s]
20
17
14
10
8
6
4
1
0.8
0.6
0.4
1
0.8
0.6
0.4
0.2
0.2
Ii =
0.1
0.08
0.06
0.04
5 6 7 8 10 12x I n
0.1
0.08
0.06
0.04
0.02
0.02
0.01
0.008
0.006
0.004
0.01
0.008
0.006
0.004
0.002
0.002
0.001
tsd [ms]
1000
750
500
without I 2t = constant function
300
200
100
60
20
0
5 6 7 8 9 10
15
20
30
0.001
40 50 60 70 80 100
Isd = 2
5 6 7 8 9 10
5 6 7 8
5 6 7 8 9 10
Ii =
x Ir
10 12 x I n
15
20
30
40 50 60 70 80 100
x Ir
x Ir
2000
2.5 h 8000
6000
4000
2.5 h 8000
6000
4000
2000
1000
800
(10 min) 600
400
1000
800
(10 min) 600
400
200
200
100
80
(1 min) 60
40
100
80
(1 min) 60
40
10
8
6
4
tr [s]
20
17
14
10
8
6
4
20
1
0.8
0.6
0.4
]=
I2t = constant
100
20
0.01
0.008
0.006
0.004
Ii =
0.1
0.08
0.06
0.04
Isd = 2
5 6 7 8 9 10
5 6 7 8
Ii =
0.2
ts
0.02
2
1
0.8
0.6
0.4
[ms
d
0.1
0.08
0.06
0.04
10
8
6
4
tr [s]
20
17
14
10
8
6
4
20
...
....
.....
0.2
x Ir
8 10 12 14 x I r
5 6
5 6 7 8 9 10
0.02
10 12 x I n
0.01
0.008
0.006
0.004
0.002
0.002
0.001
NZM4-ME...
Characteristics for I r = 1,0 x I n
5 6 7 8 9 10
15
20
30
40 50 60 70 80 100
x Ir
0.001
15
20
30
40 50 60 70 80 100
x Ir
157
Circuit-breakers, switch-disconnectors
1.7
1 NZM1
Let-through current D
200
NZMB1-A(AF)...-NA
D
[kA]
60
40
40
20
20
Ic
415 V+440 V
10
8
2x
Ic
2x
2x
60
40
60
NZMC1-A20...160
100
80
100
80
100
80
200
D
[kA]
NZMB1(-4)-A(M,S)1,2...160
Ic
200
D
[kA]
20
415 V
440 V
240 V
10
8
10
8
480 V
525 V
690 V
200
3 4 5 6 8 10 15 20 30 40 5 0 60 80 100 150
I cc rms [kA]
NZMN1(-4)-A(M,S)1,2...160
D
[kA]
200
3 4 5 6 8 10 15 20 25 35 50 60 85 1 0 0 1 5 0
I cc rms [kA]
NZMN1-A(AF)...-NA
D
[kA]
100
80
60
60
60
40
40
40
Ic
525 V
690 V
3 4 5 6 8 10 15 20 30 40 5 0 60 80 100 150
I cc rms [kA]
NZMH1(-4)-A20...160
2x
Ic
Ic
2x
20
415 V
10
8
100
80
20
200
100
80
D
[kA]
2x
20
240 V
415 V
10
8
525 V
690 V
4
3
10
8
480 V
158
3 4 5 6 8 10 15 20 30 40 5 0 60 80 100 150
I cc rms [kA]
3 4 5 6 8 10 15 20 25 35 50 60 85 1 0 0 1 5 0
I cc rms [kA]
3 4 5 6 8 10 15 20 30 40 50 60 80 1 0 0 1 5 0
I cc rms [kA]
Circuit-breakers, switch-disconnectors
1.7
NZM2
Let-through current D
D
[kA]
200
NZMB2-A(AF)...-NA
D
[kA]
200
100
80
100
80
60
60
60
40
40
Ic
100
80
NZMC2-A160...300
NZMB2(-4)-A(M,S)1,6...300
Ic
200
2x
2x
D
[kA]
440 V
NZMB2-A160...300
20
2x
Ic
40
20
10
8
20
240 V
10
8
6
415 V+440 V
NZMB2(-4-A)-M20...250
NZMB2...
4
3
480 V
10
8
600 V
440 V
525 V
690 V
200
3 4 5 6 8 10 15 20 30 40 5 0 60 80 100 150
I cc rms [kA]
NZMN2(-4)-A(M,S,VE,ME,SE)1,6...300
D
[kA]
200
3 4 5 6 8 10 15 18 20 25 35 50 60 80 1 0 0 1 5 0
I cc rms [kA]
NZMN2-A(AF)...-NA
D
[kA]
100
80
100
80
60
60
60
40
40
40
3 4 5 6 8 10 15 20 30 40 5 0 60 80 100 150
I cc rms [kA]
NZMN2-VE(VEF)...-NA
10
8
2x
20
415 V
525 V
690 V
Ic
Ic
Ic
2x
20
200
100
80
D
[kA]
2x
20
240 V
10
8
480 V
10
8
600 V
240 V
480 V
600 V
200
3 4 5 6 8 10 15 20 30 40 50 60 80 1 0 0 1 5 0
I cc rms [kA]
NZMH2(-4)-A(M,VE,ME)15...300
D
[kA]
100
80
200
3 4 5 6 8 10 15 20 25 35 50 60 85 1 0 0 1 5 0
I cc rms [kA]
NZMH2-A(AF)...-NA
D
[kA]
100
80
60
40
3 4 5 6 8 10
18 25 30 35 50 60 85 1 0 0 1 5 0
I cc rms [kA]
NZMH2-VE(VEF)...-NA
2x
415 V
525 V
20
690 V
20
240 V
10
8
Ic
Ic
Ic
60
40
10
8
100
80
40
20
200
60
2x
D
[kA]
2x
480 V
10
8
600 V
240 V
480 V
600 V
3
2
3 4 5 6 8 10 15 20 30 40 50 60 80 1 0 0 1 5 0
I cc rms [kA]
3 4 5 6 8 10 15 20 30 40 50 60 80 1 0 0 1 5 0
I cc rms [kA]
3 4 5 6 8 10 15 20 30 40 50 60 80 1 0 0 1 5 0
I cc rms [kA]
159
Circuit-breakers, switch-disconnectors
1.7
NZM3
Let-through current D
200
D
NZMN3(-4)-A...
[kA]
NZMC3(-4)-A...
100
80
100
80
2 x I cc
40
20
690 V
690 V
10
8
6
1
1
200
3 4 5 6 8 10 15 20 30 40 50 60 80 100 150
3 4 5 6 8 10 15 20 30 40 50 60 80 100 150
I cc rms [kA]
NZMN3(-4)-AE(VE,ME)220...630
I cc rms [kA]
D
[kA]
200
D
[kA]
NZMN3-VE...-NA
60
60
60
40
40
3 4 5 6 8 10 15 20 30 40 50 60 80 100 150
I cc rms [kA]
NZMH3(-4)-AE(VE,ME)220...630
525 V
Ic
690 V
690 V
Ic
Ic
2x
100
80
100
80
20
200
100
80
40
415 V
525 V
525 V
415 V
2 x I cc
40
10
8
10
8
D
[kA]
60
415 V
525 V
NZMH3(-4)-A...
2 x I cc
40
20
20
200
100
80
60
60
D
[kA]
20
240 V
2x
200
2x
D
[kA]
20
415 V
600 V
525 V
415 V
480 V
10
8
10
8
10
8
4
3
D
[kA]
200
3 4 5 6 8 10 15 20 30 40 50 60 80 1 0 0 1 5 0
I cc rms [kA]
3 4 5 6 8 10 15 20
NZMH3-VE...-NA
100
80
60
Ic
40
2x
20
240 V
480 V
600 V
10
8
6
4
160
3 4 5 6 8 10 15 20 30 40 50 60 80 1 0 0 1 5 0
I cc rms [kA]
35 42 60 85 1 0 0 1 5 0
I cc rms [kA]
3 4 5 6 8 10 15 20 30 40 50 60 80 1 0 0 1 5 0
I cc rms [kA]
Circuit-breakers, switch-disconnectors
1.7
NZM1
7
i2dt 108
NZMB1(-4)-A(M,S)
1,2...160
[A 2 s]
10 7
8 NZMC1-A20...160
s] 6
i2dt
NZMB1-A(AF)...-NA
[A 2
10 6
10 6
8
6
8
6
10 6
8
6
440 V
c 2
Ic
[A 2 s]
10 4
i2dt
4
415 V
525 V
440 V
415 V
4
690 V
240 V
10 5
8
6
10 5
8
6
10 4
10 4
3 4 5 6 8 10 15 20 30 40 50 60 80 1 0 0 1 5 0
I cc rms [kA]
i2dt
[A 2 s]
2
10 6
8
6
415 V
525 V
690 V
10 4
3 4 5 6 8 10 15 20 25 35 50 60 85 1 0 0 1 5 0
I cc rms [kA]
10 7
8 NZMN1-A(AF)...-NA
6
i2dt
[A 2 s]
10 6
8
6
10 6
8
6
415 V
240 V
3 4 5 6 8 10 15 20 30 40 50 60 80 1 0 0 1 5 0
I cc rms [kA]
10 7
8 NZMH1(-4)-A20...160
6
c 2
10 7
8 NZMN1(-4)-A(M,S)
6 1,2...160
Ic
i2dt
10 4
[A 2 s]
10 5
8
6
480 V
525 V
690 V
480 V
10 5
8
6
10 5
8
6
10 5
8
6
10 4
10 4
1
1 half-cycle
3 4 5 6 8 10 15 20 30 40 50 60 80 1 0 0 1 5 0
I cc rms [kA]
10 4
3 4 5 6 8 10 15 20
35 50 60 85 1 0 0 1 5 0
I cc rms [kA]
3 4 5 6 8 10 15 20 30 40 50 60 80 1 0 0 1 5 0
I cc rms [kA]
1 half-cycle
161
Circuit-breakers, switch-disconnectors
1.7
1 NZM2
Let-through energy I2t
7
10 7
i2dt 8
[A2 s] 6
NZMB2(-4)-A(M,S)
1,6...300
10 6
8
6
106
8
6
106
8
6
4
240 V
10 5
8
6
600 V
105
8
6
4
2
104
10 4
3 4 5 6 8 10 15 20 30 40 50 60 80 1 0 0 1 5 0
415 V
525 V
690 V
105
10 6
8
6
106
8
6
106
8
6
Ic
i2dt 108
[A2 s] 6
10 4
240 V
600 V
104
10 4
1
3 4 5 6 8 10 15
25 35 50 60 85 1 0 0 1 5 0
10 6
8
6
106
8
6
106
8
6
Ic
10 4
Ic
10 4
c 2
4
240 V
2
105
8
6
600 V
480 V
105
8
6
104
1
3 4 5 6 8 10 15 18 25 35 40 50 60 85 1 0 0 1 5 0
240 V
480 V
10 4
480 V
600 V
i2dt 107
8
[A2 s] 6 NZMH2-VE(VEF)...-NA
10 5
8
6
690 V
240 V
525 V
105
8
6
415 V
i2dt 107
8
[A2 s] 6 NZMH2-A(AF)...-NA
i2dt 10 7
8
[A2 s] 6 NZMN2-VE(VEF)...-NA
NZMH2(-4)-A(M,VE,ME)
15...300
480 V
8
6
104
10 5
8
6
i2dt 108
NZMN2-A(AF)...-NA
[A2 s] 6
NZMN2(-4)-A(M,S,VE,ME,SE)
1,6...300
3 4 5 6 8 10 15 18 25 35 50 60 80 1 0 0 1 5 0
10 4
i2dt 108
[A2 s] 6
690 V
440 V
480 V
525 V
10 5
8
6
415 V+440 V
NZMB2(-4-A)M20...300
NZMB2...
NZMC2-A160...300
Ic
Ic
440 V
NZMB2-A160...300
10 4
c 2
600 V
104
1
1 half-cycle
162
i2dt 108
[A2 s] 6
NZMB2-A(AF)...-NA
10 4
i2dt 108
[A2 s] 6
1
1 half-cycle
Circuit-breakers, switch-disconnectors
1.7
NZM3
10 7
8 NZMN3(-4)-AE(VE,ME)
220...630
6
i2dt
[A2 s]
10 7
8
6
10 7
I 2t
8 NZMC3(-4)-A...
[A2 s] 6
NZMH3(-4)-AE(VE,ME)
220...630
a
690 V
10 6
8
6
525 V
415 V
690 V
10 6
8
6
525 V
10 6
8
6
525 V
415 V
415 V
2
10 5
8
6
10 5
8
6
10 5
8
6
10 4
10 4
10 7
I2t
8 NZMN3(-4)-A...
[A2 s]
6
3 4 5 6 8 10 15 20 30 40 50 60 80 1 0 0 1 5 0
10 7
I2t
8 NZMH3(-4)-A...
[A2 s] 6
4
2
10 6
8
6
525 V
415 V
10 6
8
6
525 V
415 V
10 6
8
6
480 V
10 5
8
6
3 4 5 6 8 10 15 20 30 40 50 60 80 100 150
10 4
1
240 V
10 5
8
6
10 4
NZMN3-VE...-NA
690 V
10 5
8
6
3 4 5 6 8 10 15 20 30 40 50 60 80 100 150
690 V
i2dt 10
8
[A2 s] 6
10 4
c 2
3 4 5 6 8 10 15 20 30 40 50 60 80 1 0 0 1 5 0
Ic
10 4
600 V
2
10 4
3 4 5 6 8 10 15 20 30 40 50 60 80 100 150
3 4 5 6 8 10 15 20
35 42 50 60 85 1 0 0 1 5 0
7
i2dt 10
8 NZMH3-VE...-NA
[A2 s] 6
4
2
10 4
Ic
c 2
10 6
8
6
4
240 V
480 V
600 V
10 5
8
6
4
2
10 4
1
3 4 5 6 810
15 20 30 40 50 60 80 1 0 0 1 5 0
163
Circuit-breakers, switch-disconnectors
1.7
1
NZM2...XFIA
Frequency response
+NZM2-4-XFIA30
30 mA
+NZM2-4-XFIA
100 mA
In 10000
In
[mA]
[mA]
10000
1000
1000
100
100
10
10
100
1000
10000
10
100000
10
100
1000
10000
f [Hz]
+NZM2-4-XFIA
300 mA
1000 mA
In 10000
In 100000
[mA]
[mA]
1000
10000
100
1000
10
10
100
1000
10000
100000
f [Hz]
164
100000
f [Hz]
100
10
100
1000
10000
100000
f [Hz]
Circuit-breakers, switch-disconnectors
1.8
NZM, PN, N, NS
Technical data
General
Standards
Contact protection
Climatic proofing
1
IEC/EN 60947 and VDE 0660
Finger and back-of-hand proofto DIN EN 50274/VDE 0660 Part 514
Damp heat, constant,to IEC 60068-2-78
Damp heat, cyclic,to IEC 60068-2-30
Ambient temperature
Storage
Operation
Mechanical shock resistance QEC/EN 60068-2-27)
Safe isolation according to EN 61140
Between auxiliary contacts and
main contacts
Between the auxiliary contacts
Built-in position
0
0
C
C
9
-25...+70
-25...+70
20 (half-sinusoidal shock 20 ms)
VAC
500
VAC
300
Vertical and 900 in all directions
90
90
90
90
Direction of incoming supply
Degree of protection
Device
Enclosure
Any
In the area of the HMI devices: IP20 (basic degree of protection)
With insulating surround: IP40
With door coupling rotary handle: IP66
Tunnel terminal: IP10
Phase isolator and cable terminal: IP00
Rated uninterrupted current
max. 160 A
max. 300 A
NZMB1 NZMC1 NZMN1 NZMB2 NZMC2 NZMN2
NZMH1
NZMH2
Terminal type
Circuit-breaker
Rated impulse withstand voltage Uimp
Main contacts
Auxiliary contacts
Rated operating voltage
Overvoltage category/degree of pollution
Rated insulation voltage
For use in IT electrical power networks
Notes
6000
6000
6000
8000
8000
6000
6000
6000
6000
6000
Ue
440
690
690
440
690
500
III/3
III/3
III/3
III/3
III/3
Ui
690
690
690
690
690
V
440
690
690
440
690
V
1) Details apply for 3 pole system protection circuit-breaker with
thermomagnetic release NZMN(H)1(2)(3)-A... up to 500 A.
For rated operating voltage switching on 3 contacts the following applies
DC correction factor for instantaneous release
response value NZM1: 1.25, NZM2: 1.35, NZM3: 1.45
Setting for Ii at DCsetting Ii AC/correction factor DC
V
V
V AC
V DC1)
8000
6000
690
750
III/3
1000
690
max. 630 A
NZMC3 NZMN3
NZMH3
max. 1600 A
NZMN4 NZMH4
8000
6000
690
750
III/3
1000
690
8000
6000
690
III/3
1000
525
8000
6000
690
III/3
1000
690
8000
6000
690
III/3
1000
6902)
2)
2)>800 A525
165
1.8
1
Circuit-breakers, switch-disconnectors
NZMH1
63
53
53
Switching capacity
Rated short-circuit making capacity
240 V
400/415 V
440 V
525 V
690 V
Icm
Icm
Icm
Icm
Icm
kA
kA
kA
kA
kA
240 V 50/60 Hz
400/415 V 50/60 Hz
440 V 50/60 H
525 V 50/60 Hz
690 V 50/60 Hz
500 V DC3)
750 V DC3)
240 V 50/60 Hz
400/415 V 50/60 Hz
440 V 50/60 Hz
525 V 50/60 Hz
690 V 50/60 Hz
Icu
Icu
Icu
Icu
Icu
Icu
Icu
Ics
Ics
Ics
Ics
Ics
A gG/gL
30
kA
25
kA
kA
25
kA
kA
kA
kA
kA
30
kA
25
kA
18.5
kA
kA
NZM.1-...20...100: 20C
NZM.1-...125,160: 315
121
76
63
24
14
187
105
74
40
17
220
220
74
40
17
55
36
30
12
8
55
36
22.5
6
4
85
50
35
20
10
15
85
50
35
10
7.5
100
100
70
20
10
30
100
50
35
10
7.5
Icw
t1s
kA
125
125
Ie
750 V DC
A
3)
Ie
500 V DC
DC-3
A
125
125
Ie
750 V DC
A
Operations
Lifespan, mechanical
20000
20000
20000
20000
of which max. 50%trip by shunt/undervoltage release
Lifespan, electrical
AC-1
Operations
7500
7500
10000
10000
400/415 V 50/60 Hz
Operations
5000
7500
7500
690 V 50/60 Hz
AC-3
Operations
7500
7500
400/415 V 50/60 Hz
Operations
5000
5000
690 V 50/60 Hz
Operations
10000
10000
DC-13)
500 V DC
Operations
750 V DC
Operations
5000
5000
DC-33)
500 V DC
Operations
750 V DC
Max. operating frequency
Ops/h
120
120
120
120
Heat dissipation per pole at Iuc
16.7
16.7
16.7
16.7
W
Total opening delay on short-circuit
< 10
< 10
< 10
< 10
mS
Technical data that diverge from products for the IEC market
Switching capacity of NA switch (UL489, CSA 22.2 No. 5-09)
Short-circuit current rating (SCCR)
240 V 60 Hz
35
85
kA
351)
251)
480 V 60 Hz
kA
600 V 60 Hz
kA
Notes
1) Switching capacity of NA switches with NZM...1-...(C)NA: 480 Y/277 V
2) For rated operational current AC-3 with NZM4: 400 V: max. 650 kW; 690 V: max. 600 kW
3) DC data apply only for NZM...A... with thermomagnetic release
4) For switching capacity NZM2...NA: 600 V/347 V
5) For thermal losses per pole the specification refers to the maximum rated operational current of the construction size
6) Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit-breaker
7)For higher switching capacity please inquire
166
Circuit-breakers, switch-disconnectors
Mechanical interlock for (door-coupling) rotary handles
1.8
24
53
9
40
NZMH2
330
330
286
105
40
30
25
25
30
25
18.5
355
55
36
30
12
8
55
36
22.5
6
4
355
85
50
35
25
20
30
30
85
50
35
25
5
355
150
150
130
50
20
60
60
150
150
130
37.5
5
355
55
36
30
12
8
55
36
22.5
9
4
NZMC3...500: 630
85
50
35
25
20
30
30
85
50
35
13
5
NZMH3-...250,
400: 400
NZMH3...500: 630
NZMH3...630: 630
150
150
130
65
35
70
70
150
150
130
33
9
NZMH3-...250,
400: 400
NZMH3...500: 630
NZMH3...630: 630
50
125
50
85
35
857)
25
65
20
50
37
63
37
43
26
43
19
49
15
37
NZMN4-6301250: 2 x 630
NZMN4-1600: 2 x 800
1.9
1.9
A
1.9
1.9
A
3.3
3.3
A
3.3
3.3
A
3.3
3.3
A
19.2
19.2
B
19.2
19.2
B
300
250
300
250
20000
300
250
300
250
20000
300
250
300
250
250
250
250
250
20000
300
250
300
250
250
250
250
250
20000
500
500
450
450
15000
630
630
450
450
500
500
500
500
15000
630
630
450
450
500
500
500
500
15000
1600
1600
16002)
16002)
10000
1600
1600
16002)
16002)
10000
7500
120
19
< 10
7500
7500
5000
120
19
< 10
10000
7500
6500
5000
7500
7500
3000
3000
120
19
< 10
10000
7500
6500
5000
7500
7500
3000
3000
120
19
< 10
5000
3000
2000
2000
60
31
< 10
5000
3000
2000
2000
5000
5000
2000
2000
60
31
< 10
5000
3000
2000
2000
5000
5000
2000
2000
60
31
< 10
3000
2000
2000
1000
60
97
< 25415 V; < 35 > 415 V
3000
2000
2000
1000
60
97
< 25415 V; < 35 > 415 V
35
25
184)
85
35
254)
150
100
504)
85
42
35
150
100
50
85
42
35
125
85
50
NZMH3
330
330
286
143
74
167
1.8
1
Circuit-breakers, switch-disconnectors
Circuit-breakers, switch-disconnectors for 1000 V AC/DC
NZMH...S1, N...-4...S1-DC
Circuit-breakers for 7000 V AC
Rated operating voltage
Rated uninterrupted current
Rated operational current
AC-1
Rated short-circuit making capacity
1000 V 50/60 Hz
Rated short-circuit breaking capacity Icn
Iucaccording to IEC/EN 60947
Operating sequence O-t-CO
Ics according to IEC/EN 60947
Operating sequence O-t-CO-t-CO
Utility category
Maximum operating frequency
Durability
Mechanical(of which max. 50% trip by shunt/
undervoltage release)
Electrical, AC-1 1000 V
Rated insulation voltage
For use in IT electrical power networks
Ue
Iu
Ue
Iu
Ie
Icw
Iq
Notes
168
V AC
A
NZMH2...S1
max. 300 A
1000
NZMH3...S1
max. 630 A
1000
NZMH4...S1
max.1600 A
1000
300/50 C
630/50 C
1600/50 C
300
630
1600
Icm
kA
17
17
40
Icu
kA
10
15
20
Ics
kA
10
15
Ops/h
A
120
A
60
A/B
60
Operations
20000
15000
10000
Operations
V AC
kA
kA
A9R
Ops/h
3000
1000
N2-4...S1-DC
max. 200 A
1000
200/65 C
200 (DC 22-B)
3
15
200
120
1000
1000
N3-4...S1-DC
max. 500 A
1000
500/65 C
500 (DC 22-B)
6
15
500
60
500
1000
N4-4...S1-DC
max. 1400 A
1000
1400/65 C
1400 (DC 21-B)
25
60
Operations
20000
15000
10000
Operations
V DC
V DC
Ui
Ui
V DC
A
NZM...S1 and N...S1DC can not be combined with withdrawable units and/or connection on rear.
Can not be combined with early-make auxiliary contacts NZM~.XHIV or boxterminal NZM2-4-XKC at U;>1000 V DC
Terminal type N...S1-DC:
for 2 pole switches series connection of two poles each is required. See jumper kit NZM...-4-XKV2P
Circuit-breakers, switch-disconnectors
1.8
Switch-disconnectors
PN..., N...
Switch-disconnectors
Rated impulse withstand voltage Uimp
Main contacts
Auxiliary contacts
Rated operating voltage AC
(40-60 Hz)
Max. rated uninterrupted current
IEC/EN 60947-3
Overvoltage category/degree of pollution
Rated insulation voltage
For use in IT electrical power networks
Switching capacity
Rated short-circuit making capacity
Rated short-time withstand current
t0.3 s
t1s
Rated conditional short-circuit current Iq
With back-upfuse
PN2/N2
max. 250 A
PN3/N3
max. 630 A
N4
max. 1600 A
Ue
V
V
V AC
6000
6000
690
8000
6000
690
8000
6000
690
8000
6000
690
Iu
Ui
V AC
V
160
III/3
690
690
250
III/3
690
690
630
III/3
1000
690
1600
III/3
1000
525
Icm
kA
2.8
5.5
25
53
Icw
Icw
kA
kA
2
2
3.51)
3.51)
12
12
25
25
A gG/gL
PN1(N1)-63125: 125
PN1(N1)-160: 160
PN2(N2)-160250: 250
PN3(N3)-400630: 630
N4-6301600: 2 x 800
kA
kA
A gG/gL
100
80
PN1(N1)-63125: 125
PN1(N1)-160: 160
100
80
PN2(N2)-160250: 250
100
80
PN3(N3)-400630: 630
100
80
N4-6301600: 2 x 800
kA
kA
100
10
100
80
100
80
100
80
A
A
160
160
20000
120
250
250
20000
120
630
630
15000
60
1600
1600
10000
60
10000
7500
100004)
75004)
5000
3000
3000
2000
400/415 V
690 V
With downstream fuse
400/415 V
690 V
Rated making and breaking capacity
Rated operational current
AC-22/23A
415 V
690 V
Lifespan, mechanical
Maximum operating frequency
Lifespan, electrical according to
IEC/EN 60947-4-1 Annex B
AC-1
400/415 V
690 V
AC-3
400/415 V
690 V
Heat dissipation per pole at I}z}
Notes
PN1/N1
max. 160 A
Ie
Ie
Operations
Ops/h
Operations
Operations
3000
2000
7500
75005)
2000
1000
5000
50003)5)
12.7
16
40
97
W
1)The rated short-time withstand currentfor PN2/N2 in conjunction with residual-current release NZM2-4-XFL..
Icw1.5 kA
2) For thermal losses per pole the specification refers to the maximum rated operational current of the construction
size.
3) For the electrical life at AC-3 for PN2/N2 the following applies: 690 V: max. 160 kW
4) For 4 pole switch-disconnectors the following applies: 400/415 V 7500 switching operations; 690 V 5000 switching
operations
5) For 4 pole switch-disconnectors the following applies: 400/415 V 6000 switching operations; 690 V 4000 switching
operations
Operations
Operations
169
1.8
1
Circuit-breakers, switch-disconnectors
Molded Case Switch
NS...-...NA
NS1-...-NA
max. 125A
NS2-..: NA
max. 250A
NS3-...-NA
max. 600A
NS4-..: NA
max.1200A
V
V
VAC
6000
6000
690
8000
6000
690
8000
6000
690
8000
6000
690
ln
A
A
Uimp
125
125
III/3
690
250
250
III/3
1000
600
600
III/3
1000
1200
1200
III/3
1000
KA
KA
KA
85
35
150
100
50
150
100
50
85
65
42
KA
KA
KA
KA
KA
KA
KA
KA
KA
KA
KA
KA
KA
KA
KA
187
105
74
53
17
85
50
35
20
10
85
50
35
10
7.5
20000
330
330
286
105
53
150
150
130
50
20
150
150
130
37.5
5
20000
330
330
286
143
74
150
150
130
85
35
150
150
130
33
9
15000
187
154
143
84
74
85
70
65
40
35
43
35
33
20
18
10000
120
10000
7500
7500
5000
8.7
< 10
120
10000
7500
6500
5000
19
< 10
60
5000
3000
2000
2000
40
< 10
60
3000
2000
2000
1000
97
Uimp
Ue
240 V 60 Hz
480 V 60 Hz
600 V 60 Hz
Switching capacity divergent from products for North America.
Rated short-circuit making capacity
240 V 50/60 Hz
Icu to
IEC/EN 60947
test cycle
O-t-CO
IcsSaccording
to
IEC/EN 60947
test cycle
O-t-CO-t-CO
Lifespan, mechanical
(of which max. 50%trip by shunt/undervoltage release)
Maximum operating frequency
Lifespan, electrical
AC-1
AC-3
400/415 V 50/60 Hz
440 V 50/60 Hz
525 V 50/60 Hz
690 V 50/60 Hz
240 V 50/60 Hz
400/415 V 50/60 Hz
440 V 50/60 Hz
525 V 50/60 Hz
690 V 50/60 Hz
400/415 V 50/60 Hz
240 V 50/60 Hz
440 V 50/60 Hz
525 V 50/60 Hz
690 V 50/60 Hz
400/415 V 50/60
690 V 50/60 Hz
400/415 V 50/60
690V 50/60 Hz
170
lcm
lcm
lcm
lcm
lcm
lcu
lcu
lcu
lcu
lcu
lcs
lcs
lcs
lcs
lcs
Operations
ops./h
Operations
Operations
Operations
Operations
w
ms
1)Figures apply to the maximum rated operational current of the construction size
Circuit-breakers, switch-disconnectors
1.8
Circuit-breaker
(V)
240
480
Threshold current
Maximum
rms sym
Peak
(kA)
(kA)
8.125
7.4
8.125
9.22
NZM N1A.../AF...NA
125 A
240
480
8.125
8.125
NZMB2A.../AF...NA
250 A
NZMN2A.../AF...NA
250 A
NZMN2VE(F)-NA
250 A
NZMH2A.../AF...NA
125 A
NZMH2A... /AF...NA
250 A
NZMH2VE.../VEF...NA
250 A
NZMN3VE...NA
250 A
NZMH3VE...NA
600 A
240
480
600
240
480
600
240
480
600
240
480
600
240
480
600
240
480
600
39
25
20
240
480
600
16.25
15
10
16.25
16.25
15
16.25
16.25
15
8.125
8.125
8.125
16.25
16.25
16.25
16.25
16.25
16.25
24.5
27
25
39
39
30
Volts AC
60Hz
Part no.
Weight
kg
Circuit-breakers
NZM...1-...
NZM...1-4...
NZM...2-...
NZM...2-4...
NZM...3-...
NZM...3-4...
NZM...4-...
NZM...4-4...
Plug-in adapter elements
+NZM2-XSV
+NZM2-4-XSV
Withdrawable units
+NZM3-XAV
+NZM3-4-XAV
+NZM4-XAV
+NZM4-4-XAV
1.046
1.325
2.345
3.5
6.34
8.4
21
27
I 2dt
(kA 2s)
0.18
0.38
Intermediate current
Maximum
rms sym
Peak
(kA)
(kA)
22
13.53
18
15.16
7.4
9.22
0.18
0.38
50
22
13.00
14
12
13
13.5
14.5
12
14.5
14.5
9
9
10
13
13.5
13
11.5
14.5
14.5
1
1.8
1.8
45
35
31
0.4
0.6
0.5
0.4
0.6
0.7
0.45
0.5
0.6
0.3
0.35
0.4
0.4
0.5
0.6
0.4
0.5
0.5
4.5
2.5
2.4
22
22
14
50
22
22
50
22
22
100
55
42
100
65
30
100
65
30
100
65
42
Part no.
Switch-disconnectors
PN1-..N1-...
PN1-4-..., N1-4-...
PN2-..., N2-...
PN2-4-..., N2-4-...
PN3-...,N3-...
PN3-4-..., N3-4...
N4-...
N4-4-
I 2dt
(kA 2s)
0.33
0.67
I 2dt
(kA 2s)
0.35
0.78
18.53
18.55
0.38
0.97
85
35
19.16
20.58
0.36
1.02
14.5
13.5
14.5
17
14.5
16.5
18
18
17
19
23
22.5
20.5
24
20
18.5
24
20
35
39
37
0.6
0.45
0.75
0.45
0.6
0.8
0.4
0.65
0.75
0.35
0.7
0.7
0.4
0.9
0.7
0.3
0.6
0.6
85
42
35
2
3
3
35
25
18
85
35
25
85
35
25
200
150
55
150
100
50
150
100
50
33.5
35
34
150
100
50
15.5
16.5
15.5
19.5
20
17
19.5
20
18
21.5
29
26
20
27
25
21
27
25
1.1
1.8
2.6
40
47
42
0.4
0.6
0.75
0.45
0.65
0.75
0.4
0.6
0.65
0.35
0.85
0.8
0.4
0.8
0.9
0.4
0.7
0.8
240
480
600
2.5
3
2.8
Weight
kg
0.926
1.325
2.15
2.65
5.7
7.1
17
22
4.7
5 .9
21
27
52
65
171
1.8
1
Circuit-breakers, switch-disconnectors
Temperature dependency, derating
NZM...A(F), NZM...M(S)
Device part no
Release type
Device part no
Notes
172
Release type
Response time of the overload release at temperatures deviating from the reference
temperatures
Temperature compensation coefficient
30 0C
40 0C
50 0C
60 0C
65 0C
70 0C
20 0C
TM
TM
TM
TM with SVE
TM
TM
TM with SVE
TM with SVE
TM
TM with XAV
0.88
0.88
0.88
0.90
0.90
1
Response time of the overload release at temperatures deviating from the reference
temperatures
Temperature compensation coefficient
30 0C
40 0C
50 0C
60 0C
65 0C
70 0C
20 0C
1
1
1
1
1
1
1
1
1
1
0.86
0.83
1
1
1
0.95
0.9
0.85
1
1
1
1
1
1
1
0.92
0.87
0.81
1
1
1
1
1
1
1
1
1
1
0.9
0.85
1
1
1
1
1
1
1
0.97
0.92
0.87
0.81
1
1
1
0.94
0.88
0.85
1
1
0.94
0.88
0.82
0.79
Motor protection (reference temperature 20 C)
TM
1
1
1
1
1
1
TM
1
1
1
1
0.86
0.83
TM with SVE
1
0.92
0.87
0.81
TM
1
1
1
1
1
1
TM with SVE
1
1
1
1
1
1
1
1
1
0.94
0.88
0.85
TM with/without XAV
1
1
1
0.94
0.88
0.85
TM
1
1
1
1
1
1
TM with/without XAV
1
1
1
1
1
0.97
In determining the maximum permissible current loads at different ambient temperatures, the derating coefficients
listed inthetable must be considered.
Example:
An NZM2-A250 should be operated at an ambient airtemperature of 65 0C.
How high is the permissible rated operational current le?
At 65 0C the derating coefficient is 0.85, i.e.le250Ax0.85212.5 A.
At an ambient temperature of 650C the NZM2-A250 can therefore be operated at up to le212.5 A.
0.79
0.79
0.88
0.79
0.94
0.94
0.94
0.94
0.82
0.76
1
0.8
0.8
1
1
0.8
1
0.82
0.76
1
0.8
1
1
0.82
0.82
1
0.94
Circuit-breakers, switch-disconnectors
Derating
1.8
Release type
E
E
E with XAV
E with XAV
E
E
E with XAV
E with XAV
1
1
1
0.96
1
1
1
1
1
1
1
0.92
1
1
1
0.98
1
1
1
0.87
1
1
1
0.93
1
1
1
0.83
1
1
1
0.89
1
0.9
1
0.78
1
0.87
1
0.85
1
0.85
1
0.75
1
0.85
1
0.83
1
0.8
1
0.73
1
0.82
1
0.8
E
E
E with XAVE
E with XAV
E
E
E with XAV
E with XAV
E
E
E with XAV
E with XAV
1
1
1
1
1
1
1
0.96
1
1
1
1
1
1
1
1
1
1
1
0.92
1
1
1
0.98
1
1
1
1
1
1
1
0.87
1
1
1
0.93
1
1
1
0.94
1
1
1
0.83
1
1
1
0.89
1
0.9
1
0.88
1
0.9
1
0.78
1
0.87
1
0.85
1
0.85
1
0.84
1
0.85
1
0.75
1
0.85
1
0.83
1
0.8
1
0.81
1
0.8
1
0.73
1
0.82
1
0.8
E
E
E with XAV
E with XAV
E
E
E with XAV
E with XAV
E
E
E with XAV
E with XAV
1
1
1
1
1
1
1
0.96
1
1
1
1
1
1
1
1
1
1
1
0.92
1
1
1
0.98
1
1
1
1
1
1
1
0.87
1
1
1
0.93
1
1
1
0.94
1
1
1
0.83
1
1
1
0.89
1
0.9
1
0.88
1
1
1
0.78
1
1
1
0.85
1
0.85
1
0.84
1
1
1
0.75
1
1
1
0.83
1
0.8
1
0.81
1
1
1
0.73
1
1
1
0.8
1
1
1
1
1
1
1
1
1
1
0.96
1
1
1
1
1
1
1
1
1
1
0.97
1
1
1
0.92
1
1
1
0.98
1
1
1
1
1
1
0.92
1
1
1
0.87
1
1
1
0.93
1
1
0.95
1
1
1
0.87
1
0.94
1
0.83
1
1
1
0.89
1
0.86
0.9
1
0.9
1
0.81
1
0.89
1
0.78
1
0.87
1
0.85
1
0.83
0.85
1
0.85
1
1
1
0.86
1
0.75
1
0.85
1
0.83
1
0.8
0.8
1
0.8
1
1
1
0.84
1
0.73
1
0.82
1
0.8
with XAD
1
0.84
0.96
0.82
0.92
0.8
0.88
In determining the maximum permissible current loads at different ambient temperatures,
the derating coefficients listed in the table must be considered.
Example:
An NZM2-A250 should be operated at an ambient air temperature of 65 0C.
How high is the permissible rated operational current le?
At 65 0C the derating coefficient is 0.85, this means le250Ax0.85212.5 A.
The NZM2-A250 may be operated at an ambient temperature of 65 0C with a maximum
le212.5 A.
173
Circuit-breakers, switch-disconnectors
1.8
1.6
2.4
12
15
18
20
9.8
8180
25
8.8
4680
26
30
32
9.3
3030
33
35
40
10.7
2220
13.5
2810
45
50
13.2
1760
14.1
1880
60
63
14.2
1190
14.9
1250
70
80
16.3
850
20.8
1085
90
100
21.9
730
23.9
795
110
125
26.7
570
150
160
36.1
470
175
200
225
250
300
400
500
NZM2/3/4 with electronic release
Fixed mounted
NZM2-...
Ln[A]
200
250
Ln[A]
450
630
Ln[A]
1250
1400
1400
174
P
[W]
5.5
9.8
8.8
8.2
8.2
10.7
10.7
13.2
12.9
12.5
16.3
17.7
21.9
20.7
26.7
B
[ohms]
8180
8180
4680
3030
2220
2220
1760
1760
1190
850
850
730
730
570
570
P
[W]
52
B
[ohms]
275
N2/3/4, PN2/3
Fixed mounted
N2-...
PN2-...
B
P
[ohms]
[W]
48
256
NZM3-...
P
[W]
119
B
[ohms]
100
NZM3-...
P
[W]
107
NZM4-...
P
[W]
52
B
[ohms]
275
NZM4-...
P
[W]
284
P
[W]
1.8
0.8
1.8
0.7
1.8
0.7
1.6
2.0
3.4
2.7
4.2
6.7
10.8
16.9
B
[ohms]
413000
66000
66000
9180
9180
1670
1670
1050
1050
562
562
562
562
562
N2-4-..: S1-DC
IN+L1+L2+L31
P
[W]
44
B
[ohms]
275
B
[ohms]
90
NZM3-...
P
[W]
122
B
[ohms]
150
B
[ohms]
37
NZM4-...
P
[W]
231
290
B
[ohms]
37
37
P
[W]
6.7
16.9
26.3
B
[ohms]
562
562
562
P
[W]
11.4
17.8
29.2
B
[ohms]
380
380
380
380
Ln[A]
250
NZM2-...
P
[W]
19
B
[ohms]
100
Circuit-breakers, switch-disconnectors
Active power loss
1.8
5.1
4250
8
4250
9.6
3140
13.4
2800
17
2270
20.2
1700
20.5
1070
25.7
855
27.6
589
38.4
500
48
400
58.1
310
83.7
310
Notes:
P
[W]
5.1
8
9.6
13.4
17
20.2
20.5
25.7
27.6
38.4
48
B
[ohms]
4250
4250
3140
2800
2270
1700
1070
855
589
500
400
P
[W]
2.9
5.1
5.9
8.5
10.3
13.4
13.8
17
18.4
15.7
20.5
20.8
25.7
21.4
27.6
33.6
36.8
48
47.1
58.1
83.7
B
[ohms]
4250
4250
3140
3140
2800
2800
2270
2270
1700
1070
1070
855
855
589
589
500
400
400
310
310
310
P
[W]
5.8
7.8
0.3
0.9
0.5
1.2
1.6
2.5
1.5
2.4
3.8
6.1
9.5
14.9
24.3
38
59.4
85.6
The values stated in the table apply for 3 and 4 pole fixed
mounted devices with an equal load distribution.
On 4 pole devices the current in the neutral conductor is equal to zero
The total resistive load is the measured value for a 3 pole or a 4 pole
switch(independent of I} and the type of release.
B
[ohms]
750000
450000
4600
4600
1200
1200
780
780
317
317
317
317
317
317
317
317
317
317
P
[W]
24.3
38
59.4
B
[ohms]
317
317
317
P
[W]
19.7
30.7
48
B
[ohms]
256
256
256
P
[W]
68
79
72
93
Thetotal resistive load for a switch orwithdrawable plug results from
the resistive value for fixed mounting+resistive value
for plug-in orwithdrawable.
The heat dissipation can be calculated with the
formula: P3xRxl2
B
[ohms]
364
256
151
124
175
Circuit-breakers, switch-disconnectors
1.8
1
Terminal capacities
2-hole
mm2
Notes
176
In1)
A
In1)
A
Boxterminal
Screwterminals
Tunnel terminals
Rearterminal bolts
Screwterminal
Boxterminal
Tunnel terminals
Rearterminal bolts
Screwterminal
Boxterminal
Tunnel terminals
Rearterminal bolts
300
2x16
1 x (35-240 ,2x(25-120)
1 x (25-185)2)
1 x (50-240)
2 x (50-240)
500
1 x16,2x16
1 x (25-240) ,2x (25-240)
2x300
630 ,2x185
1-hole
Double-hole
1 x (10-16) ,2x(4-16)
1 x (25-185)3) ,2x(25-70)
1x16
1 x (25-185)
4-hole
mm2
mm2
mm2
mm2
mm2
mm2
mm2
mm2
1 x (10-16) ,2x(6-16)
1 x (25-70)3) ,2x25
160
1 x (10-16) ,2x(4-16)
1 x (25-185) ,2x(25-70)
300
mm2
mm2
mm2
mm2
1 x 16
1 x (25-95)
160
1 x 16
1 x (25-185)
250
mm2
1 x (10-16) ,2x(10-16)
1 x (25-35) ,2x(25-35)
160
1 x (10-16) ,2x(10-16)
1 x (25-50) ,2x(25-50)
250
2x9x0.8
9x9x0.8
160
2x9x0.8
10x16x0.8
2x8x15.5x0.8
300
mm
mm
mm
mm
mm
300
mm2
2x16x0.8
10x24x0.8
min.
max
min.
max
1-hole
Double-hole
4-hole
min.
max.
mm2
mm2
mm2
mm2
mm2
Module plate
1-hole
Screwterminals and connection on rear
Copper strip, perforated
Copper strip, perforated
NZM2, PN2, N2
NS2 300 A
1 x (10-16) ,2x(6-16)
1 x (25-70)3) ,2x(6-25)
1x16
1 x (25-95)
Module plate
2-hole
Connection width extension
Singleflat cableterminal
In1)
A
mm2
mm2
mm2
mm2
NZM1, PN1, N1
NS1 160A
min.
max.
min.
max.
160
160
M6
M8
mm
160
12x5
16x5
mm
16x5
24x8
mm
1-hole
min.
Module plate
max.
mm
mm
2-hole
Module plate
mm
min.
max.
mm
1)The rated currents In have been determined according to IEC/EN 60947
(switchgear standard) and generally relate to the max. defined cross-sections.They are given for general reference here.
The engineering standards which apply in each case must be observed
2)To 240 mm2 can be connected depending on the make of cable.
3)To95 mm2 can be connected depending on the make of cable.
min.
max.
300
300
350
630
2x185
630 ,2x185
1 x 16
1 x (25-185)3)
1 x (50-240) ,2x (50-240)
350
1 x16 ,2x(10-16)
1 x (25-120) ,2x(25-120)
400
6x16x0.8
10x24x1.0
+5x24x1.0
(2x)8x24x1.0
630
6x16x0.8
10x32x1.0
+5x32x1.0
(2x)10x50x1.0
630
M10
20x5
30 x 10, +30 x 5
2x(10x50)
630
630
630
10x40
Circuit-breakers, switch-disconnectors
1.8
Terminal capacities
NS, NZM-NA
NZM4, N4, NS4
7 600 A
Screwterminal
Tunnel terminals
Rearterminal bolts
Strip terminal
Ln1)
A
4 x (50-240)
NZM...1...NA,
NS1...NA
Box terminal
Screwterminals
Tunnel terminals
Rearterminalbolts
NZM...2...NA,
NS2...NA
Screwterminal
Boxterminal
Tunnel terminals
Rearterminal bolts
NZM...3...NA,
NS3...NA
Screw terminal
Box terminal
Tunnel terminals
Rearterminalbolts
NZM...4...NA,
NS4...NA
Screw terminal
Tunnel terminals
Rearterminalbolts
Strip terminal
1400
AWG
AWG/kcmil
AWG
AWG/kcmil
AWG/kcmil
AWG/kcmil
1 x (126)
1x(4-2/0)
1x6
1x(4-3/0)
1 x (126)
1x(4-350)
1x6
1x(4-350)
1 x (2500)
1x6
1x(4-350)
1x(0-500) ,2x(0-500)
4x(0-500)
AWG
1 x (126)
1 x (120185)
4x(50185)
1 x (120300)
2 x (95300)
2 x (95185)
4 x (35185)
4 x 300
6x1952401
1250
AWG/kcmil
1 x (126)
2x(96)
1x(42/0)
1x(42/0)
1000
kcmil
AWG/kcmil
AWG/kcmil
AWG/kcmil
AWG/kcmil
1x(4350)
2x350
2x 500
1 x (250350)
4x(0350)
1 x (250600)
2 x (3/0600)
2 x (3/0350)
4x(2350)
4 x 600
6 x (3/0500)
4 x (50-240)
1400
AWG
AWG/kcmil
AWG/kcmil
AWG/kcmil
1 x (185240)
2 x (70185)
4 x 50
2 x 240
6x170240)
Please inquire
Please inquire
Please inquire
AWG
AWG/kcmil
kcmil
AWG/kcmil
AWG
AWG/kcmil
mm
mm
2x9x0.8
9x9x0.8
2x9x0.8
10x16x0.8
6x16x0.8
(2x)10x32x1.0
(2x110x50x1.0
1100
mm
mm
mm
6x16x0.8
10 x 24 x 1.0
+5x24x1.0
(2x)8x24x1.0
6x16x0.8
(2x) 10x32x 1.0
(2x110x50x1.0
(2x)10x50x1.0
(2x110x50x1.0
1600
mm
mm
mm
2x16x0.8
10x16x0.8
(2x110x80x1.0
1600
2x(10x50x1.0)
1600
M10
25x5
2x150x10),2 x (80x 10)
25x5
2x150x10)
2x150x10)
60 x 10
2 x (80 x 10)
1400
1600
4 x 240
1250
(2x)10x40x1.0
1250
2 x (40 x 10)
1600
1600
2 x (50 x 10)
mm
mm
mm
mm
mm
mm
mm
M6
12x5
16x5
M8
16x5
20x5
6x16x0.8
10x32x1.0
+5x32x1.0
(2x)10x50x1.0
(2x)10x50x1.0
(2x)10x50x1.0
M10
20 x 5
30 x 10, +30 x 5
2x110x50)
M10
25x5
2 x (50 x 10)
25x5
2 x (50 x 10)
2 x (50 x 10)
60 x 10
2 x (80 x 10)
(2x)10x80x 1.0
177
Circuit-breakers, switch-disconnectors
1.8
Temperature dependency
1 N...S1-DC
Jumper kits
Basic devices
Reduction of the rated operational current (derating) under particular ambient conditions
Contact
Mounting Temperature compensation coefficient
protection position 20 0C
20 0C
20 0C
20 0C
20 0C
20 0C
20 0C
20 0C
Switch-disconnectors
N2-4-160-S1DC
+NZM2-4-XKV2P
IP2X
v
h
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
N2-4-200-S1DC
+NZM2-4-XKV2P
IP2X
v
h
1
1
1
1
1
1
1
1
1
1
1
1
1
0.95
0.95
0.92
N3-4-320(400)-S1DC
+NZM3-4-XKV2P
IP2X
v
h
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
N 3-4-500-S 1DC
+NZM3-4-XKVI2P
IP00
v
h
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
N2-4-160-S1DC
+NZM3-4-XKVI2P-K
IP00
v
h
1
1
1
1
1
1
1
1
1
1
1
1
1
0.97
0.97
0.95
+NZM3-4-XKVI2P
IP00
v
h
1
1
1
1
1
1
1
0.97
0.97
0.95
0.95
0.92
0.92
0.89
0.89
0.87
+NZM3-4-XKV2P-K
IP1X
v
h
1
1
1
1
1
1
1
1
1
0.97
0.98
0.94
0.95
0.91
0.92
0.89
+NZM3-4-XKV2P-K
IP2X
v
h
1
1
1
1
1
0.98
0.95
0.93
0.92
0.9
0.89
0.87
0.86
0.84
0.83
0.81
N4-4-800110001-S1-DC
+NZM4-4-XKV2P
IP2X
v
h
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
N 4-4-1250-S 1DC
+NZM4-4-XKV2P
IP2X
v
h
1
1
1
1
1
1
1
1
1
1
1
1
1
0.97
0.97
0.95
N 4-4-1400-S 1DC
+NZM4-4-XKV2P
IP2X
v
h
1
1
1
1
1
0.97
0.94
0.91
0.92
0.9
+NZM3-4-XKV2P-1400 IP00
v
h
1
1
1
1
1
1
1
1
11)
11)
11)
11)
11)
11)
0.97
0.97
Notes
178
Mounting position:
vvertical, hhorizontal
Incomer and outgoer at bottom or top, freely selectable
1)
Incomer at from bottom only.
Circuit-breakers, switch-disconnectors
Auxiliary contacts, equipping, time differences
1.8
M22-K, XHI(V)
Auxiliary contacts
Rated operating voltage
AC voltage
DC voltage
Conventional thermal current
Rated operational current
AC-15
115 V
230 V
400 V
500 V
DC-13
24 V
42 V
60 V
110 V
220 V
Short-circuit protection
Max.fuse
Max. miniature circuit-breaker
Early make times compared to main contacts
on make and break(switching times on manual
operation.
At AC=50/60 Hz
M22-K...
M22-CK...
XHIV
Ua
Ua
LthLe
V AC
V DC
A
500
220
4
230
220
4
500
220
4
Le
Le
Le
Le
Le
Le
Le
Le
Le
A
A
A
A
A
A
A
A
A
4
4
2
1
3
1.1
1.2
0.8
0.3
4
4
3
1
0.8
0.5
0.2
4
4
2
1
3
1.5
0.8
0.5
0.2
A gG/gL
A
ms
10
PKZMO-10/FAZ-B6
10
FAZ-B6/B 1
10
FAZ-B6
mm2
1 x (0.752.5)
2 x (0.752.5)
1x(1814)
2x(1814)
1 x (0.51.5)
2 x (0.51.5)
1x(2018)
2x(2018)
1 x (0.752.5)
2 x (0.752.5)
1x(1814)
2x(1814)
Terminal capacities
Solid or flexible conductor with ferrule
AWG
A
Le
UL/CSA
Rated operational current
10A...600 V AC
1A250 V DC
A600/P300
via 300 V AC
same polarity
Time differences ON-OFF
a
b
c
NZM1, N/S}1
NZM2, N/S}2
NZM3, N/S}3
NZM4, N/S}4
PN1
PN2
PN3
-XHIV2S)
or-XA
or-XU
1
1
1
1
1
1
1
HIA
HIN
1
1
1
2
1
2
3
3
1
2
3
2.5 A240 V AC
1A250 V DC
C300/R300
Main contact
NZM1
K01
2.5
NZM2
202)
3.5
6.5
NZM3
202)
NZM4
902)
11
Notes
K01
K01
2.5
2.5
4.5
202)
4.5
NZM1
202)
3.5
Please
inquire
Please
inquire
01)2)
12
15
Motor drive
HIV
HIN
K10
Not
permissible
Not
permissible
Not
permissible
Motor drive
HIV
Not
permissible
Not
permissible
Not
permissible
HIN
K10
K01
6.5
Please
inquire
Please
inquire
179
1.8
NZM...-XU, NZM...-XA...
Undervoltage releases
Rated control voltage
AC voltage at 50/60 Hz
Us
DC voltage
Us
Operating range
Drop-out voltage
Pick-up voltage
Power consumption
AC voltage
AC pick-up rating
AC consumption when closed
DC voltage
DC pick-up rating
DC consumption when closed
Max. opening delay(response time until the main circuits
open)
Minimum signal duration
Terminal capacities
Solid or flexible conductor with ferrule
NZM112/31-XU...
NZM4-XU...
V AC
V DC
24...600
12...250
24...600
12...250
x Us
x Us
0.350.7
0.851.1
0.350.7
0.851.1
VA
VA
1.5
1.5
3.6
3.6
W
W
0.8
0.8
2.5
2.5
1X(0.75-2.5)
2X(0.75-2.5)
1X(0.75-2.5)
2X(0.75-2.5)
ms
mm2
A WG 1X(18-14)
2X(18-14)
1X(18-14)
2X(18-14)
UVU-NZM
Ue
Ue
le
tsd
Us
Us
V AC
V DC
mA
VA
ms
s
s
24, 220550
24
<500
50
704000
To 16
To 8
mm2
1 x (0.52.5)
2 x 10.51.5)
Ue
le
le
V AC
mA
A
mm2
AW
G
1 x (0.52.5)
1 x (2014)
2x12016)
NZM112/31-XA...
NZM4-XA
NZM2/3-XA...-MNS
NZM4-XA...-MNS
V AC
V DC
Hz
12...440
12...440
0400
12...440
12...440
0400
230
50/60
230
50/60
x Us
x Us
0.7...1.1
0.7...1.1
0.7...1.1
0.7...1.1
0.1...1.1
0.1...1.1
VA/W 2.5
VA/W 2.5
A
ms
2.5
2.5
22
0.5
20
1
22
ms
ms
1000ms
1000ms
1015
1015
1015
1015
1 x (0.752.5)
2 x (0.752.5)
1x(18-14)
2x(18-14)
1 x (0.752.5)
2 x (0.752.5)
1x(18-14)
2x(18-14)
1 x (0.752.5)
2 x (0.752.5)
1x(18-14)
2x(18-14)
1 x (0.752.5)
2 x (0.752.5)
1x(18-14)
2x(18-14)
mm2
AWG
180
NZM-XCM
Capacitor unit for shunt release
Circuit-breakers, switch-disconnectors
Circuit-breakers, switch-disconnectors
1.8
1
Remote operators
Rated control voltage
AC voltage
DC voltage
Operating range
AC voltage
DC voltage
Rated operational power
AC voltage
DC voltage
Us
Us
110 V...130VAC
208 V...240 V AC
380 V...440 V AC
24 V...30 V D C
110 V...130VDC
220 V...250 V DC
NZM2-XRD...
NZM2-XR...
NZM3-XR...
NZM4-XR...
100...440
24...250
100...440
24...250
100...440
24...250
100...440
24...250
0.85...1.1
0.85...1.1
0.85...1.1
0.85...1.1
0.85...1.1
0.85...1.1
0.85...1.1
0.85...1.1
VA
VA
VA
W
W
W
ms
ms
550
550
650
450
450
450
110-170
110-170
350
350
350
250(max. 17A 30 ms)
250
250
60
3000
350
350
350
250
250
250
80
1000
350
350
350
250
250
250
100
3000
ms
ms
Opa/h
30
500
20000
120
30
150
20000
120
30
250
15000
60
30
500
10000
20
mm2
AWG
0.752.5
1814
0.752.5
1814
0.752.5
1814
0.752.5
1814
V AC
V DC
Operations
PFR-003
Electrical
Standards
Sensitivity
Rated control voltage
Motor rating
Rated fault currents
Deceleration time
Relay contacts
Rated operating voltage of the relay contacts
Rated operational current of the relay contacts
Fault current early warning
Mechanical
Standard front dimension
Device height
Built-in width
Mounting
Terminals top and bottom
Terminal protection
Terminal capacities
Sealing facility for setting buttons
Us
Pe
Ln
tv
V AC
W
A
s
VAC/DC
A
Hz
mm
mm
mm
mm2
PFR-03
45
45
85
85
36
36
Quick attachment fortop-hat rail DIN 46277, EN 50022
Boxterminals
Finger and back-of-hand proof BGV A2, VDE 106 Part 100
2 x 0.752.5 solid, 2 x 0.751.5 flexible/with sleeve
PFR-5
3
0.03,0.1,0.3,0.5,3,5
0.02,0.1,0.3,0.5,3,5
1 built-in changeover contact
250/100
6
0.525%50%ln
150%75%ln
275%100%ln
45
85
36
Yes
181
Circuit-breakers, switch-disconnectors
1.8
1
Earth-fault releases
NZM...-XFI...
NZM11-41-XFI30R
NZM11-41-XFI300R
NZM11-41-XFIR
Electrical
Standards
Sensitivity
Min. operating voltage
For detecting type A/AC fault
currents
For detecting type B fault currents
+NZM2-4-XFI30
+NZM2-4-XFI
+NZM2-4-XFIA30
+NZM2-4-XFIA
NZMH2..: XFIA30
80 V (dependent on
mains power)
80 V (dependent on
mains power)
80 V (dependent on
mains power)
80 V (dependent on
mains power)
IEC/EN 60947-2
Pulse-current sensitive, type A
Ue
f
V AC
Hz
ln
ln
A
A
lm
182
NZM11-41-XFI30U
NZM11-41-XFI300U
NZM11-41-XFIU
0.03
0.3
0.03-0.1-0.3-0.5-1-3
0.03
0.3
0.03-0.1-0.3-0.5-1-3
0.03
0.03-0.1-0.3-0.5-1-3
50/60 Hz
50/60 Hz
50/60 Hz
Lcu
Lcu
Lcu
0.3 x ln
0.3 x ln
20(ha1f-sinusoidal shock20 ms)
20000
20000
Operations
mm
mm2
mm2
45
45
On right side
Bottom
Vertical and 900 in all directions
NZM1 from above
NZM1 from above
IP20 inthe operating component area
-5...+40
-5...+40
Same as NZM1 standardterminal
Same as NZM1 standardterminal
Yes, setting buttons
0.03
0.3-1
0.03
With AC voltage:
0100 kHz
With pulsed DC
voltage: 50 Hz
Lcu
20000
20000
NZMH2: 20000
96
Bottom
96
Bottom
Any
Bottom
-25...+70
-25...+70
Circuit-breakers, switch-disconnectors
Data Management Interface (DMI module)
1.8
NZM-XU, NZM-XA
1
DMI
General
Dimensions (W x H x D)
Modular spacing(space units)
Weight
Mounting
Ambient climatic conditions
Operating ambienttemperature
Built-in position
Condensation
LCD display (clearly legible)
Storage/transport
Relative humidity, non-condensing (IEC/EN 60068-2-30)
Air pressure(in operation)
Corrosion resistance
IEC/EN 60068-2-42
IEC/EN 60068-2-43
Ambient mechanical conditions
Pollution degree
Degree of protection IEC/EN 60529
Vibrations (IEC/EN 60068-2-6)
Constant amplitude 0.15 mm
Constant acceleration, 2 g
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11
Drop IEC/EN 60068-2-3
Free fall, packaged (IEC/EN 60068-2-32)
Power supply
Rated operating voltage
Permissible range
Residual ripple
Input current at 24 V DC
Voltage dips (IEC/EN 61131-2)
Power loss at 24 V DC
mm
kg
C
C
%
hPa
0 to +55
Horizontal/vertical
Prevent condensation by means of suitable measures
0 to +55
-40 to +70
5 ...95
795...1080
cm3/m3
10
cm3/m3
O
O
4 days
SO2
4 days
HZS
107.5 x 90 x 53
6 SU (space units) wide
0.3
Top-hat rail IEC/EN 60715, 35 mm
2
IP20
Drop
height
Ue
Hz
Hz
Shocks
mm
10...57
57...150
18
50
V DC
V DC
%
mA
ms
W
24
20.4...28.8
5
210
10
5
183
Circuit-breakers, switch-disconnectors
1.8
1
Fieldbus interface
EASY22..., NZM-XDMI
EASY221-CO
General
Standards
Dimensions (VV x H x D)
mm
Weight
Mounting
kg
EASY222-DN
NZM-XDMI-DPV1
Terminal capacity
Solid
Flexible with ferrule
Standard screwdriver
Max. tightening torque
mm2
mm2
mm
Nm
C
%
hPa
4070
595
7951080
cm3/m3
cm3/m3
10
1
10
1
10
1
2
IP20
2
IP20
2
IP20
Hz
Hz
Shocks
1057
57150
18
1057
57150
18
1057
57150
18
mm
m
50
1
horizontal x
vertical
50
1
horizontal x
vertical
50
1
horizontal x
vertical
kV
kV
V/m
8
6
10
EN 55011 ClassB
EN 55022 ClassB
8
6
10
8
6
10
EN 55011 ClassA
EN 55022 ClassA
kV
kV
kV
2
2
2
2
0.5 (supply cables, symmetrical)
2
2
10
10
Condensation
Storage
Relative humidity, non-condensing (IEC/EN 60068-2-30)
Air pressure (in operation)
Corrosion resistance
IEC/EN 60068-2-42
IEC/EN 60068-2-43
Ambient mechanical conditions
Pollution degree
Degree of protection (IEC/EN 60529)
Vibrations (IEC/EN 60068-2-6)
Constant amplitude 0.15 mm
Constant acceleration, 2 g
Mechanical shock resistance (IEC/EN 60068-2-27)
semi-sinusoidal 15 g/11ms
Drop (IEC/EN 60 068-2-31)
Free fall, packaged (IEC/EN 60068-2-32)
Mounting position
4 day SO2
4 day SO2
Drop height
184
3.5 x 0.8
0.6
10
3.5 x 0.8
0.6
Circuit-breakers, switch-disconnectors
1.8
Fieldbus interface
EASY..., NZM-...
Insulation resistance
Clearances and creepage
distances
Insulation resistance
Power supply
Rated operating voltage
Permissible range
Ripple
At 24 V D C
Voltage dips (IEC/EN 61131-2)
Heat dissipation at 24 V DC
Polarity reversal protection
Power supply
LED indicators
Power supply
LED display
Network
Terminal type
Potential isolation
Function
Interface
Bus protocol
Baud rates
Bus terminating resistors
Bus addresses
Services
Cyclical
Acyclical
EASY221-CO
EASY222-DN
NZM-XDMI-DPV1
Ue
V
V DC
%
mA
ms
24-15/+20%)
20.4-28.8
<5
typ. 200
10
24-15/+20%)
20.4-28.8
<5
typ. 200
10
24-15/+20%)
20.4-28.8
<5
typ. 200
10
4.8
4.8
4.8
Yes
Yes
Yes
RJ45
StatusOn/Dff,tripped[detailed)
load early warnings, phase
currents I}/h/13[A], remote
operator acutation, display/
operation NZM-XDM1612
inputs/outputs, motor starter
functions
Display/match protection
protection settings, event list,
identification, hours of
operation, switching
operations, time
185
SmartWire-Darwin
1.8
1 NZM-XSWD
NZM-XSWD-704
General
Standards
Dimensions (W x H x D)
Weight
Mounting
Built-in position
Ambient mechanical conditions
Degree of protection (IEC/EN 60529)
VibrationsllEC/EN 61131-2:2008)
Constant amplitude 3.5 mm
Constant acceleration, 1 g
Mechanical shock resistance (IEC/EN 60068-2-27)
semi-sinusoidal 15 g/11 ms
Drop (IEC/EN 60068-2-31)
Free fall, packaged (IEC/EN 60068-2-32)
Electromagnetic compatibility (EMC)
Overvoltage category
Pollution degree
Electrostatic discharge (IEC/EN 61131-2:2008)
Air discharge (Level 3)
Contact discharge (Level 2)
Electromagnetic fields (IEC/EN 61131-2:2008)
80 -1000 M Hz
1.4-2 GHz
2-2.7 GHz
Radio interference suppression (SmartWire-Darwin)
Burst (IEC/EN 61131-2:2008, Level 3)
Supply cables
Signal cables
SmartWire-Darwin cables
Surge (IEC/EN 61131-2:2008, Level 1)
Radiated RFIIIEC/EN 61131-2:2008,Level3)
Ambient climatic conditions
Operating ambient temperature (IEC 60068-2)
Condensation
Storage
Relative humidity, non-condensing (IEC/EN 60068-2-30)
SmartWire-Darwin status
Station type
Baud rate setting
SmartWire-Darwin status
Connection
186
mm
kg
IEC/EN 61131-2
EN 50178
35 x 90 x 101
0.1
Top-hat rail IEC/EN 60715, 35 mm
Vertical
IP20
Drop height
Hz
Hz
Shocks
5 8.4
8.4 150
9
mm
m
50
0.3
II
2
kV
kV
8
4
V/m
V/m
V/m
10
3
1
EN 55011 Class A
kV
kV
2
1
1
10
kV
V
O
C
%
LED
mm2
mm2
Ue
1)Minimum length 8 mm
V
%
25 +55
Prevent with suitable measures
4070
5 95
SmartWire-Darwin station (slave)
Automatic
Green
8-pin connector
Connection plug: External device plug
SWD4-8SF2-5
See separate table
Push-In
0.2-1.5 (AWG 24-16)
0.25-1.5
SmartWire-Darwin
SWD input/output modules
1.8
NZM-XSWD
NZM-XSWD-704
Digital inputs
Number
Input current
Voltage level to IEC/EN 61131-2
Limit value type 1
Input delay
Status display inputs
Digital semiconductor outputs
Number
Output current
Short-circuittripping current
Lamp load
Overload proof
Switching capacity
Relay outputs
Number
Contact type
Operations
Utilization category AC-1, 250 V, 6 A
Utilization category AC-15, 250 V, 3 A
Utilization category DC-13, 24 V, 1 A
Safe disconnection
Minimum load current
Response/reset time
Bounce duration
Short-circuit protection
Status display outputs
Potential isolation
Inputs for SmartWire-Darwin
Semiconductor outputs to SmartWire-Darwin
Semiconductor outputs to inputs
Relays to SmartWire-Darwin
Relays to inputs
Relays to relays
RLL
mA
2
Typically 4 at 24 V DC
LED
A
A
W
2
0.2 at 24 V DC
V AC
mA
mS
mS
LED
Yes
Yes
187
Circuit-breakers, switch-disconnectors
1.8
1
NZM-...XMC
General
Dimensions
mm
Weight
Material characteristic
Environmental conditions
Operating temperature
Storage temperature
Humidity (non-condensed)
Maximum operating altitude
IP protection class
Supply
Voltage
Maximum current
Conductors
Voltage measurement
Rated operating voltage
Maximum surge voltage at8/ms
Maximum voltage
Surge impedance (impedance)
Frequency
Accuracy
Overvoltage category according to EN61010
Current measurement
Rated operational current
Maximum current
Maximum currentimpulse 1s
Frequency
Category EN61010
Power measurement
Maximum power (per phase)
Accuracy
Accuracy, active power
Accuracy, reactive energy
Pulse output
Outputtype
VCE max
VCE sat
Ic max
Ic recommended
Isolation
Max. switching frequency
Pulse width
Pulse rate power
Digital output
Type
Maximum voltage
Maximum current
Isolation
Digital input
Maximum voltage
VIHmax
MODBUS output-RS485
Data rate
Stop bits
Parity
Isolation
Outputdisplay
DC supply voltage
Maximum current
188
NZM2-XMC-S0
209 91 132 (3 pole)
251 91 132 (4 pole)
850 (3 pole)
975 (4 pole)
UL94-V0
NZM3-XMC-S0
209 91 132 (3 pole)
251 91 132 (4 pole)
850 (3 pole)
975 (4 pole)
UL94-V0
NZM2/3-XMC-MB
209 91 132 (3 pole)
251 91 132 (4 pole)
850 (3 pole)
975 (4 pole)
UL94-V0
C
C
%
m
-15-+65
-40-+80
5-95
2000
IP 20
-15-+65
-40-+80
5-95
2000
IP 20
-15-+65
-40-+80
5-95
2000
IP 20
V DC
mA
18 36
200
Phoenix Contact GMVSTBR
2.5-2-ST-7.62
18 36
200
Phoenix Contact GMVSTBR
2.5-2-ST-7.62
18 36
200
Phoenix Contact GMVSTBR
2.5-2-ST-7.62
V AC
kV
V AC
kohms
Hz
690
8
800
1
45-65
0.4 % measured value
+0.05 % FS
CAT IV (600 V)
690
8
800
1
45-65
0.4 % measured value
+0.05 % FS
CAT IV (600 V)
690
8
800
1
45-65
0.4 % measured value
+0.05 % FS
CAT IV (600 V)
A AC
A AC
kA
Hz
300
350
30
45-200
CAT IV-600 V
500
740
30
45-200
CAT IV-600 V
kwh
Class 1 (IEC62053-21)
Class 1 (IEC62053-21)
280
0.95 % measurement
+ 0.05 % FS
Class 1 (IEC62053-21)
Class 2 (IEC62053-23)
V
V
mA
mA
kV
H2
ms
Pulses/kN
NPN-isolated transistor
80
0.4
50
10
3
2
120
15
NPN-isolated transistor
80
0.4
50
10
3
2
120
7.5
V
mA
kV
350
120
2.5
V
V
50
3
bit/s
kV
VDC
mA
5
180
0
0
NPN-isolated transistor
80
0.4
50
10
3
4
20
Circuit-breakers, switch-disconnectors
1.9
Circuit-breakers
Switch-disconnectors
3 pole
NZMB1
a
30
NZMC1
NZMN1
NZMH1
PN1
N1
NS1
68
f 60
21
57
R 1
04
45
145
126
112
64
41.5
16
9.5
10.2
NZM...1-...-(C)NA
90
63
162
M4 x 50/10
SW4
30
44.6
90
Circuit-breakers
Switch-disconnectors
4 pole
NZMB1-4
a
60
NZMC1-4
NZMN1-4
NZMH1-4
PN1-4
N1-4
89
68
63
45
145
126
112
R1
04
64
41.5
16
9.5
f 60
21
30
SW4
M4 x 50
44.6
120
Covers
NZM 11-41-XKSA
Screw terminals
NZM 11-41-XKS
IP2Xprotectionagainst
contact with a finger
for cover
21
Switch-disconnectors
ATEX22-type
3 pole
PN 1../ATEX22
4
IP2X
SW 4
681.5
629.5
~ 743
16
158
34
80
288.5
64
296
26
M6 x 14
NZM1(-4)-XIPA
322.5
90 a
120 b
340.5
3 pole
4 pole
190
234.5
59
189
Circuit-breakers, switch-disconnectors
1.9
20
3 pole
4 pole
M6 x 14
64
SW 4
32
48
SW 5
30
30
30
30 15
90 a
120b
126
M6 x 14
102
10
10
50
M4
30
30
18
15
o 6.6
90
128
SW 4
64
63
o 22
o 22
2 5
126
M6 x 20
128
63
120
15
M4
120 b
3 pole
4 pole
190
64
91
108
90 a
90 a
120 b
76
13
46
89
Circuit-breakers, switch-disconnectors
1.9
NZM1-XDV..., NZM1-XTVD...
Rotary mechanism
Rotary handle on circuit-breaker
NZM1-XDV
NLM-XDVR
NZM1-XDTV
36
F 43
54
45
80.3
35
35
80
80
45
90
d=48
b<
= 34
120
Up to 3 padlocks
73.5
27.5
8
71
85
40
23
o 8
ZFS...-NZM7
R4
71
85
35
2 5
d=48
b<
= 34
Up to 3 padlocks
191
Circuit-breakers, switch-disconnectors
1.9
NZM1-XTVD...
73.5
27.5
o 45
55
36
NZM1/2-XV4(NZM1/2-XV6)
NZM1-XTVDIVIIRI-601-NA)
23g 0.5
NZM1-XTVDIVIIRI-0(NA)
41 75
16 60
NZM1/2-XV...
167 210
23g 0.5
a
128 167
Special tip
Minimum distance of door coupling rotary handle from door pivot point
NZM...1-... f 130
192
23g 0.5
Circuit-breakers, switch-disconnectors
1.9
NZM1-XS, NZM1...HIV
51.5
41
129
12
2-5
73.5
95-310
90
90
Main switch assembly kit for side wall installation with mounting bracket
NZM1-XSIRIM-L
12
2-5
95-310
73.5
129
15
NZM1-XSIRIM-R
145
145
NZM1/2-XZB
NZM1/2-XZB
131.4
2-5
12
73.5
12
176
57.2
57.2
178.5
131.4
2-5
176
73.5
178.5
163
163
195.5
195.5
Undervoltage releases
Shunt releases (for power circuit breaker)
Early-make auxiliary contacts
Spacers
NZM1/2-XAB
38.6
23.2
39.3
20
39.3
20
NZM1-XA(HIV)
NZM1-XU(HIV)(20)
NZM1-XHIV
NZM1-XA(HIV)(L)
NZM1-XU(V)(HIV)(L)(20)
NZM1-XHIV(L)
NZM1-XHIVR
Clip plate
NZM1-XC35
9.5
103
35
157
126
145
17.5
30
1.5
90
8.4
193
Circuit-breakers, switch-disconnectors
1.9
1 NZM...-X...
9.5
Insulating surround
NZM1-XBR
Mounting aperture
1.5 5
53
82
64
ZFS...-NZM7
132
11.5
23
117
19
148.5
9.5
Insulating surround
NZM1-XBRS64
13
ZFS...-NZM7
87
104
23
78
61
10
17.5
Mounting aperture
32
9.5
1.5 5
14.4
9
53
11
40
o 4
132
11.5
19
Rear-mounted drives
NZM1-XRAV(R)
NZM1-4-XRAVIR)
46.3
145
32
117 a
115
148 b
NZM1-XRAV(R)
NZM1-4-XRAV(R)
F 80
d=48
b<
= 34
Up to 3 padlocks
194
Circuit-breakers, switch-disconnectors
1.9
NZM1-XMV, NZM1-XTV...
Mechanical interlock
NZM1-XMV+NZM1-XDVIR)
31
45
22.5
27
51
80.3
29.2
7
5
45
40
90
143
120
40
NZM1-XMV+NZM1-XTVDIVIIR)
NZM1/2-XV4 (NZM1/2-XV6)
Part no.
NZM1/2-XV4
NZM1/2-XV6
x
245 400
400 600
NZM1-XMV+NZM1-XTVD(V)(R)-60
NZM1-XMV+NZM1-XTVD(V)(R)-60
NZM1/2-XV...
163 202
202 245
Special tip
195
Circuit-breakers, switch-disconnectors
1.9
31
45
22.5
R6
4
80.3
27
NZM1/2-XV4(NZM1/2-XV6)
7
5
5/20
40
45
143
40
95/110 (125/140)
90
120
NZM1-XC123-T
250
280
Insulated enclosures
NZM1-XCIKS-T
160
200
187.5
175
231
495
375
495
375
60
60
NZM1-XCI43-T
248.5
60
80
60
80
175
250
225
250
298.5
248.5
117
Plug-in units
NZM1-XSVS with
NZM.1~SVE
N1--SVE
62.3
48.5
30
21
SW4
200
Component adapter
NZM1-XAD160
90
d=48
b<
= 34
Up to 2 padlocks
145
30
90
100
NZM1-XSVS
NZM1-...SVE
202.3
190
64
196
171
126
Circuit-breakers, switch-disconnectors
1.9
NZM1...-XFI..., PFR-...
1
5
45
67
85
Residual-current relays
PFR-003
PFR-03
PFR-5
44
36
68
73
Ring-type transformer
PFR-W-20...30
PFR-W-35...210
F
32
32
G
60
70
H
24
30
I
46
59
J
21
30
PFR-W-35
PFR-W-70
PFR-W-105
PFR-W-140
PFR-W-210
A
100
130
170
220
299
B
79
110
146
196
284
C
26
32
38
48.5
69
D
48.5
66
94
123
161
E
35
70
105
140
210
Part no.
PFR-W-20
PFR-W-30
33
6.5
46
F
C
32.7
51.7
Magnetic shielding
PFR-WMA
A1
Part no.
PFR-WMA-35
PFR-WMA-70
PFR-WMA-105
PFR-WMA-140
PFR-WMA-210
Mounting clip
PFR-WC
F
35
52
72
97
141
A2
A
91
105
153
153
153
B
28
62
98
133
203
C
40
75
110
145
215
A1
35
35
35
35
35
A2
28
35
60
60
60
6.0
12.5
80.1
68
45
42.5
220
220
145
145
Earth-fault release
NZM 11-41-XFL..R
135
105
80.1
68
NZM1(-4)-XFI...U
45
42.5
145
145
23.1
120
90.15
197
Circuit-breakers, switch-disconnectors
1.9
35
149
NZM...2-...(C)NA
f 35
103
5
19.5
11
25
R 12
80
184
145
135
24.5
M8 x 22
95
100
72.5
64
f 35
217
SW5
35
b
M4 x 85/20
f 5 NZM...2-...-(C)NA(>
NS2-...-NA
105
78.7
480 V)
149
103
f 35
70
19.5
25
95
R 12
4
80
184
135
145
24.5
M8 x 22
72.5
100
SW5
f 35
35
a
b
140
f 5
78.7
f 5
288.5
340.5
198
~743
681.5
629.5
Switch-disconnectors
ATEX22-type
3 pole
PN2.../ATEX22
322.5
a
f 5
16
190
276
M4 x 85/20
Circuit-breakers, switch-disconnectors
Construction size 2: accessories
1.9
Tunnel terminal
NZM21-41-XKA
30
25
19
65
25
F 22.1
55
SW 5
M8 x 22
80
111
80
20
M10
37
SW 8
SW 5
105
140
105 a
140 b
3 pole
4 pole
Covers
NZM21-41-XKSA
Cable lug
NZM2-XKS185
IP2X protection against contact with a finger for cover
NZM21-41-XI PA
NZM2-(4)-XKSAE
73.3
NZM2-XKS185
SW 5
M8 x 22
81
63.5
175
337
310.7
80
M8 x 22
64
103.3
105 a
87
140 b
105 a
138.4
140 b
Jumper kit
NZM2-4-XKVP
105
88
100
93
3 pole
4 pole
105 a
88
140 b
35
35
140
35
3 pole
4 pole
199
Circuit-breakers, switch-disconnectors
1.9
35
35
35
72
80
80
22.5
145
48
18
10
160
100
10
105
35
8.6
M4
140
17.5
70
35
35
22.5
160
145
72
80
o 20
M8 x 30
M4
18
35
NZM2-XDV
NZM2-XDVR
NZM2-XDTV
NZM2-XDTV2
R4
59
F 67
100
95
75
35
52
35
88
104
140
200
88
Rotary mechanism
Rotary handle on circuit-breaker
d=48
b<
= 34
Up to 3 padlocks
Circuit-breakers, switch-disconnectors
Construction size 2: accessories
1.9
NZM2-XTV..., NZM1/2-XV4(6)
73.5
d=48
b<
= 34
Up to 3 padlocks
71
85
40
23
ZFS...-NZM7
R4
6
71
85
25
35
73
27
8
45
17
55
NZM1/2-XV4(NZM1/2-XV6)
36
23g 0.5
F 3
245 600
201
Circuit-breakers, switch-disconnectors
1.9
1 NZM2-XTVD..., NZM2-XS...
Door coupling rotary handle with extension shaft
NZM2-XTVDIVIIRI-601-NAI
NZM2-XTVDIVIIRI-0(NAI
41 75
16 60
NZM...2-... f 130
NZM1/2-XV...
23g 0.5
205 249
172 205
23g 0.5
Special tip
Main switch assembly kit for side wall installation
NZM2-XSIRI-L
2-5
73.5
0.5
95-310
170.5
105
NZM2-XS(R)-R
51.5
41
0.5
105
202
15
2-5
95-310
73.5
170.5
Circuit-breakers, switch-disconnectors
Construction size 2: accessories
1.9
NZM2-XS..., NZM2...-XRAV...
Main switch assembly kit for side wall installation with mounting bracket.
NZM2-XSIRIM-L
185
NZM1/2-XZB
172.1
2-5
73.5
0.5
216
47.2
218.5
168
200.5
185
NZM2-XSIRIM-R
NZM1/2-XZB
0.5
172.1
2-5
47.2
216
73.5
168
218.5
200.5
184
Rear-mounted drives
NZM21-41-XRAVIR)
133 a
145
168 b
NZM2-XRAV(R)
NZM2-4-XRAV(R)
203
Circuit-breakers, switch-disconnectors
1.9
Spacers
NZM1/2-XAB
Clip plate
NZM2-XC75
17.5
130
169
NZM1/2-XAB
35
105
120.5
17
Insulating surround
ZFS...-NZM7
NZM2-XBR
9.5
Mounting aperture
1.5 5
103
64
132
127
142
158.5
23
10
17.5
9.5
NZM2/3-XBRS
13
64
ZFS...-NZM7
Mounting aperture
154
138
23
78
95
10
17.5
Mounting aperture
32
9.5
10.4
1.5 5
9
o 4
103
63
NZM2-XDTV(R)
142
10
17.5
204
1.9
Circuit-breakers, switch-disconnectors
Construction size 2: accessories
NZM2...-XKAV, NZM2...-XSH
Toggle lever locking device
NZM2/3-XKAV
a
50
1.3
d=48
b f 34
Up to 3 padlocks
92.5
F 88
Part no.
NZM2, PN2, N2
NZM3, PN3, N3
a
52.5
70
F 600
80
25
184
30
54
R1
80
Side-mounted handle
NZM2...-XS H
R75
19.5
d=48
b f 34
145
174.4
Up to 3 padlocks
35
Drilling template
205
Circuit-breakers, switch-disconnectors
1.9
95
50
75
73
36
50
47.5
9.6
50
52.5
41
105
180
140
46
NZM2-XMV+NZM2-XTVDIVIIR)
NZM1/2-XV4 (NZM1/2-XV6)
NZM2-XMV+NZM2-XTVDIVIIRI-60
NZM2-XMV+NZM2-XTIVIDIVIIRI-0
a
NZM1/2-XV...
240 284
207 240
Special tip
206
Circuit-breakers, switch-disconnectors
Construction size 2: accessories
1.9
PN2-XPA, NZM2-XR...
Paralleling mechanism
PN2-XPA
11
50
17
45
50
R8
NZM1/2-XV4(NZM1/2-XV6)
5/20
9.9
50
6.5
52.5
42
105/125 (140/160)
180
46
105
140
Up to 3 padlocks
Remote operator folded
322.8
235.5
35
135
d=48
b<
= 34
21.5
7.2
NZM2-XAVPR
Remote operators
NZM2-XR
105
F 13.7
250
105
52.5
105
140
NZM2-XRD
225
11.9
125
10
14
21.5
7.2
35
NZM2-XAVPR
78
95
F 10.6
105
35
250
105
52.5
52.5
59.9
59.5
105
140
207
Circuit-breakers, switch-disconnectors
1.9
660
250
187.5
500
17
495
375
17
80
60
Insulated enclosures
NZM2-XC143-T
60
80
225
250
298.5
Component adapter
NZM2-XAD250
190
60
375
225
298.5
20
190
145
20
145
35
63
35
35
106
35
190.5
15.7
Plug-in units
NZM2-...-SVE
N2-...SVE
NZM21-41-XSVS
92.3
87.5
148.3
67.1
25
57.5
M8 x 22
NZM2(-4)-XSVE
SW5
M4 x 93
M4 x 85
35
105
140
78.7
208
241
396
237
184
109.7
NZM2(-4)-XSVS
205
Circuit-breakers, switch-disconnectors
Construction size 2: accessories
1.9
Earth-fault release
NZMH2...-XFIA30
105
291
35
22
291
29.5
29.5
252
22
22
265
29.5
22
265
252
35
110.75
52.5
22
87.7
103
29.5
70
35
108
140
149
6
22
70
103
35
108
149
140
NZM-XDMI
EASY2
NZM-XDMDPV1
EASY2
75
7.5
16.25
M4
110
90
102
45
M4
4.5
47.5
56.5
107.5
7.5
58
35.5
100
115
60
M4 X 16
50
78
M5 X 16
85
209
1.9
NZM...3-...-4(C)NA
a
120.5
11
f 60
45
20.5
31
5
M10 x 30
135
R 205
123.5
95
275
234
216
28 29.5
Circuit-breakers
Switch-disconnectors b
3 pole
NZMC3
PN3
N3
NS3
117
315.5
f 60
SW5
45
b
166
90
2 0 .5
120.5
31
135
M10 x 30
28 29.5
Circuit-breakers
Switch-disconnectors b
4 pole
NZMC3-4
NZMN3-4
NZMH3-4
PN3-4
N 3-4
M5 x 75
69.7
f 5
140
f 60
f 5
117
95
R 205
123.4
275
234
216
f 60
SW5
45
a
f 5
f 5
185
69.7
288.5
288.5
~1146
1023.5
53
288.5
53
340.5
Switch-disconnectors
ATEX22-type
3 pole
PN3.../ATEX22
16
Circuit-breakers, switch-disconnectors
320.5
230
340.5
210
316
M5 x 75
Circuit-breakers, switch-disconnectors
Construction size 3: accessories
1.9
54
25
75
26.5
31
Tunnel terminal
NZM31-41-XKAi (2)
32
27
F 18.7
80
SW 8
M10 x 30
124
124
172
25
SW 8
35 25
SW 8
M12
SW 5
140
185
140
185
Cover
NZM31-41-XKSA
Cable lug
NZM3-XKS185
IP2X protection against contact with a finger
NZM31-41-XI PA
NZM3-XKS185/240
NZM3(-4)-XKSAE
M10 x 30
124
79.7
SW 8
96
68
253
410.8
459
M10 x 30
130
140
185
73.5
140 a
103
175
185 b
3 pole
4 pole
211
1.9
NZM3...XK...
Connection width extension
NZM31-41-XKV70
Terminals
NZM31-41-XK22X21
NZM31-41-XK300
70
70
45
26.5
37
33
70
43
70
24
6
70
20 50 18
13
50
401
433
295
616
401
433
295
123.5
5.75
28
11.5
M10 x 30
6.4
NZM3(-4)-XK22X21
NZM3(-4)-XK300
200
45 45
45 45 45
140
188
258
255
325
36.5
21
149
598.2
148
49
185
24
140 a
60.5
161.6
200
185 b
230
170.4
44
23
M12
45
25
70 70
35
185
34
116
255
3 pole
4 pole
90
31
140
119.3
210
134.3
45
45
45
45
30
SW 8
22
11 57
140
11
35
M5
90
M5
22
185
45
28
M10X35
212
124
247
234
247
112
11
117
124
234
117
123.5
30
10
Circuit-breakers, switch-disconnectors
Circuit-breakers, switch-disconnectors
Construction size 3: accessories
1.9
325
Jumper kit
NZM31-41-XKV2P
110
155
66.25
200
445.5
106
390
45
45
191.55
31
M10 x 40
M5 x 25
45
185
185
3.5
599
161.6
200
616
Phase isolators
NZM3-4-XKP
100
45
Mounting aperture
90
9.5
210
1.5 5
255
Spacers
NZM3-XAB
a
138
ZFS...-NZM7
64
132
110
17.5
177
NZM3-XAB
10
162
193.5
23
17.5
213
1.9
NZM3-XDV..., NZM3-XTVD...
Rotary drive
Rotary handle on circuit-breaker
<= 82.6
105
NZM3-XDV
NZM3-XDVR
95
124
R8
35
140
109
185
71
40
23
ZFS...-NZM7
85
R87
71
85
25
35
Circuit-breakers, switch-disconnectors
d=48
b <
= 34
214
Up to 3 padlocks
Circuit-breakers, switch-disconnectors
Construction size 3: accessories
1.9
NZM3-XTVD
25
X
27
8
60
32.5
59
NZM3/4-XV4(6)
36
23g 0.5
29
Part no
NZM3/4-XV4
NZM3/4-XV6
270 400
400 600
NZM3-XTVDVIRI-60(NA)
NZM3-XTVDVIRI-0(NA)
18 60
42 77.5
NZM3/4-XV...
235 277
199.5 235
23g 0.5
23g 0.5
Special tip
Minimum distance of door coupling rotary handle from door pivot point
NZM...3-...<
=180
215
1.9
Circuit-breakers, switch-disconnectors
Construction size 3: accessories
1 NZM3-XS..., NZM3
105
25
86 433
195
95
25
105
NZM3-XS(R)-R
39.1
86 433
24.1
195
25
25
95
Side-mounted handle
NZM3... XSH
<= 600
275
22.5
32
R1
80
80
216
5
R7
Circuit-breakers, switch-disconnectors
Construction size 3: accessories
1.9
Mechanical interlock
NZM3-XMV+NZM3-XDV(R)
50
47.5
95
50
73.2
105
34.5
96.5
20
5
99
40
140
196
185
69
NZM3-XMV+NZM3-XTVDIVIIR)
NZM3/4-XV4(NZM3/4-XV6)
NZM3-XMV+NZM3-XTVDIVIIRI-60
NZM3-XMV+NZM3-XTVDIVIIRI-0
a
NZM3/4-XV...
235 270
270 312
Special tip
217
1.9
Circuit-breakers, switch-disconnectors
Construction size 3: accessories
50
50
30
47.5
95
R 137
30
105
Paralleling mechanism
PN3-XPA
20
5
99
(40)
40
180/225
196
69
140
185
PN3-XPA
NZM3/4-XV4(NZM3/4-XV6)
Insulated enclosures
NZM3-XC148-TD
750
910
32.5
229
270
80
Component adapter
NZM3-XAD550
375
45
29
190
375
218
45
140
60
275
370
38
63
Circuit-breakers, switch-disconnectors
Construction size 3: accessories
1.9
NZM3-X2..., NZM3...XSVS
358
260.5
d=48
b f 34
143.5
60.5
Remote operators
NZM3-XR
Up to 3 padlocks
Remote operator folded
5.5
NZM3-XAVPR
28
17
10
291.5
95
140
<= 13
140
70
140
185
309 d
299 e
271 f
5
171
313.5
341.6
130
170.8
130
151.8
200
25
175.8
25
91
225.5
SW 8
45
31
96
M10X30
400
200 a
520
227 a
250 b
3 pole
4 pole
272 b
d=48
b f 34
Disconnected
Test
Connected
Up to 3 padlocks
219
1.9
Circuit-breakers, switch-disconnectors
Construction size 4: basic devices
207
204
138
70
33
b
15
M5 x 110
15
10.5
b
70
<= 15
25
100
<= 15
45
210
Blow-out area, minimum clearance to other parts 100mm up to 690 V; 200 mm up to 1000 V
Minimum clearance to adjacent parts15mm
4 pole
NZMN4-4
NZMH4-4
N4-4
140
207
138
33
21
M5 x 110
15
10.5
b
45
70
100
25
<= 15
<= 15
280
220
100
117
87.5
401
313
15
180
171.5
119
108
44
<= 100
100
117
87.5
21
401
180
313
171.5
119
108
44
100
1.9
Circuit-breakers, switch-disconnectors
Construction size 4: accessories
NZM4...-XK
Covers
NZM41-41-XKSA
Tunnel terminal
NZM4-4-XKA
60
128
<= 100
53
32
<= 100
108.5
25
4 x SW8
73.5
M10 x 60
171.5
531
30.5
2 x SW16
210
280 b
210
280 b
3 pole
4 pole
Clearance from conductive parts100 mm up to 690 V; 200 mm up to 1000 V
Screw terminals
Module plate
1-hole
NZM41-41-XK M 1
2-hole
NZM41-41-XKM2
Part no.
NZM4(-4)-XKM1
NZM4(-4)-XKM2
NZM4(-4)-XKB
40
43
43
NZM4-XKM2
11
NZM4(-4)-XKB
SW5
b
NZM4(-4)-XKB
a
SW16
b
47
40
47
3 pole
4 pole
Clearance from conductive parts
100 mm up to 690 V;
200 mm up to 1000 V
50
25
a
36
32
M10 x 50
171.5
NZM4-XKM1
210 a
280 b
221
Circuit-breakers, switch-disconnectors
1.9
NZM4...-XKM, XKV
Module plate
2 hole, vertical
NZM41-41-XKM2S
33
13
70
70
70
o 13
16
16
70
70
32
32
M 10X50
50
518
486
518
486
171.5
SW16
50
210
280
Part no.
NZM4(-4)-XKM2S-1250
NZM4(-4)-XKM2S-1600
X
12
20
95
107.5
77 18
50
107.5
77
48
30.5
NZM4-XKV95
15
NZM4-XKV110
11
11
171.5
15
M10 x 50
15
573
800
543
320
781
573
SW16
543
NZM4-XISP
30
210
267
30
28.5
210
113.5
41
292
360
222
Circuit-breakers, switch-disconnectors
Construction size 4: accessories
1.9
NZM4...-XKV
NZM4-4-XKV95
95
18
50
30
NZM4-4-XKV120
47.5 47.5
18
77
95
18
80
50
122
42
122
42
48
15
NZM4-4-XKV120
M1
15
15
NZM4-4-XKV95
122
42
NZM4-4-XISP
NZM4-4-XKP
11
800
625
595
320
573
781
543
171.5
11
NZM4-4-XISP
18
30
30
280
41
83
Cover, large
NZM4-XKSAV
48
95
86
30
15
M12
210
276
360
33
116
230
190
38
781
800
573
SW16
401
171.5
M10x50
541
44
95
140
210
33
120
290
223
1.9
Circuit-breakers, switch-disconnectors
Construction size 4: accessories
1 NZM4(-4)-XKP, NZM4(-4)-XKR
NZM4-4-XKV95
NZM4-4-XKV120
SW16
NZM4-4-XISP
NZM4-4-XKP
278
M10
172
139
180
9.5
88
411
30
15
210
M5
206
16
280 b
3-5
208
104
70
140
87.5
Cover, large
NZM4-XKSAV
205.5
M5
35
70
280
125.5
108.5
NZM4-4-XKV2P
171.5
522
466
M10 x 60
SW 16
SW 16
56
190
32
o 13
70
70
50
3.5
114
70
140
224
280
70
16
NZM4-4-XKM2S-1600
33
20
411
180
25
45
72
o 11
Circuit-breakers, switch-disconnectors
Construction size 4: accessories
1.9
NZM4-XAS..., NZM12
Jumper kit
NZM4-4-XKV2P-1400
240
80.5
NZM4-4-XKV2P-1400
201
M10 x 65
SW 16
613
M10 x 55
SW 16
56
32
13
70
16
NZM4-4-XKM2S-1600
70
70
33
50
20
31
45
280
11
118
98.5
108
98.5
50
218
570
(38)
118
540
530
108
78.5
500
78.5
32
32
14
14
43
50
20
66
50
60
100
343
218
95.5
536.5
98
4.5
180
19 64.5 93.5
d
70
79
79
210
276
225
1.9
Dimensions
Construction size 4: NZM12 replacement
1 NZM12, NZM4-XAS...
Replacement of NZM12-1000(1250) with NZM4 with module plate,
fixed mounting on mounting plate
NZM4-XAS12-1000(1250)
184
79
39.5
93.5
79
39.5
96.5
22
15
599
578.5
536.5
141.5
141.5
22
68.5
68.5 55
14
184
50
10 (NZM12-1250)
8 (NZM12-1000)
25
79
10 (NZM12-1000)
98.5
98.5
15 (NZM12-1250)
248
6
276
59
248
15
215.8
276
59
215.8
96.5
50
15
60
93.5
22
48.5
14
10 (NZM12-1250)
50
23
55.5
128
578.5
536.5
55.5
192.5
599
98
192.5
22
48.5
34
128
8 (NZM12-1000)
60
95.5
39.5
57
79 79
10 (NZM12-1000)
39.5
15 (NZM12-1250)
57
79
79
210
59
186.5
243.7
264.1
226
210
15
59
186.5
243.7
264.1
Dimensions
Construction size 4: N12 replacement
1.9
N4-XAS-12
79
184
79
39.5
93.5
96.5
22
141.5
411
374
476
68.5 55
14
15
22
68.5
319
141.5
184
50
10 (N12-1250)
8 (N12-1000)
79
39.5
25
79
8.5
98.5
98.5
248
15
248
59
276
74
276
215.8
215.8
93.5
22
48.5
48.5
23
86
50
29.5
13.5
515
475
438
192.5
192.5
22
45
86
14
34
15
60
8 (N12-1000)
60
96.5
50
10 (N12-1250)
50
8.5
39.5
57
79
59
79
210
39.5
57
186.5
243.7
264.1
79 79
210
15
74
186.5
243.7
264.1
227
1.9
NZM4-XDV..., NZM4-XTVD...
Rotary handle on circuit-breaker
NZM4-XDV(R)
57
204
69
221.5
33
117
73.5
<= 89.5
60.5
58.5
R 137
162
210
280
d=48
b f 34
Up to 3 padlocks
Door coupling rotary handles
NZM4-XTVD(V)(R)...
70
18
85
R1
37
a
Up to 3 padlocks
b
d=48
b f 34
228
71
71
40
23
o 8
ZFS...-NZM7
85
Circuit-breakers, switch-disconnectors
Circuit-breakers, switch-disconnectors
Construction size 4: accessories
1.9
25
5
27
8
60
21
59
36
23g 0.5
NZM3/4-XV4(NZM3/4-XV6)
57
NZM4-XTVDIVIIRI-601-NA)
NZM4-XTVDIVIIRI-0I-NA)
42 77.5
18 60
NZM3/4-XV...
270 312
234.5 270
23g 0.5
23g 0.5
Special tip
Minimum distance of door coupling rotary handle from door pivot point
NZM...4-... <=180
86 433
34.1
24.1
100
221.5
25
229
1.9
Circuit-breakers, switch-disconnectors
Construction size 4: accessories
9.5
1.5 5
NZM4-XBR
Mounting aperture
ZFS...-NZM7
125
64
154
246
231
23
262.5
10
17.5
NZM4-XBRS
9.5
13
Mounting aperture
64
ZFS...-NZM7
179
163
23
123
136
10
17.5
Mechanical interlock
NZM4-XMV + NZM4-XDV(R)
47.5
50
95
20
5
40
162
210
280
230
230
69
73.2
50
221.5
34.5
Circuit-breakers, switch-disconnectors
Construction size 4: accessories
1.9
NZM4-XMV + NZM4-XTVD(V)(R)-0
Mechanical interlock
NZM4-XMV+NZM4-XTVDIVIIR)
1
NZM4-XMV+NZM4-XTVDIVIIRI-60
NZM3/4-XV4(NZM3/4-XV6)
NZM3/4-XV...
305 347
NZM4-XMV+NZM4-XTVDIVIIRI-0
270 305
Special tip
231
Circuit-breakers, switch-disconnectors
1.9
NZM4...-XAV
Remote operators
NZM4-XR
435.2
313.4
d=48
bf
34
175.4
Up to 3 padlocks
Remote operator folded
12.5
F 13.4
84.4
b
189.5
189.5
208
208
210
210
280
Withdrawable unit
+NZM4-4-XAV
341e
d=48
bf
34
3 pole
4 pole
Disconnected
Test
Connected
353.5 d
313f
Up to 3 padlocks
243
274.5
217
25 25
M6x12
451
300
509
30
R1
70
131
275
297
560
350
367
232
33
680
454.4
189
117
55.6
45.5
306.4
19.4
204
25 25
Circuit-breakers, switch-disconnectors
Mechanical interlock for (door-coupling) rotary handles
1.9
NZM...XMC, NZM-XSWD
132
108
43.75
R 10.5
56.5
5.5
140
91
42
191
209
NZM2 (3)(-4)...XMC-SO(MB)
27.5
132
108
43.75
R 10.5
56.5
5.5
182
91
42
232
250
90
35
4.5
97
233
Eaton Corporation
Asia Pacific Headquarter
No.3, Lane 280, Linhong Road,
Changning District,
Shanghai 200335
Tel: 86-21-52000099
Fax: 86-21-52000200
2011 Eaton Corporation
All Rights Reserved
Printed in China