Maintenance
Overview
The Traditional grease interceptor line is the
cornerstone product of the Pioneering concept.
For more than fifty years, Jay R. Smith Mfg.
Co. has conducted hundreds of tests, in the
laboratory and in the field, in order to offer
the most efficient Grease Interceptors with
improved operational characteristics suitable
for most applications. The Traditional Grease
Interceptor is designed for practical
applications. These interceptors bear the
certification seal of the Plumbing and
Drainage Institute (PDI). Rating, sizing and
special features of these units can be found
in the Smith Yellow Pages Catalog, 8000
Series Interceptors. The Traditional line may
be installed either on-grade, semi-recessed
or fully recessed in the floor. In addition,
the fully recessed installations have the
option of a partially or completely enclosed
cradle to act as a drip pan.
The Traditional Grease Interceptor is recommended for areas where the accumulation
of grease, fat, oil or other similar line-clogging
contaminants should be prevented from
entering the drainage line. The Traditional
Grease Interceptor should always be
considered when designing the plumbing
drainage system in any restaurant, cafeteria,
hotel, school, hospital, institutional or
commercial building as well as food
processing plants, dairies and other industries
having facilities for the preparation and
serving of food in quantity. In these installations, where grease and fats are by-products,
an efficient Smith interceptor should be
installed to prevent this material from
entering the drainage line.
Remove cover.
Inspect Interceptor.
Remove grease (FOG) from top of separation chamber.
Remove any solids from bottom of chamber.
Make certain all passages, including air relief, are clear of obstructions.
Check integrity of baffles and
make sure they are in place.
Lock and Lift Ring
Check cover gasket for any
Non-Skid Cover
Cleanout
damage. Replace if necessary.
Reinstall cover.
Tighten cover hold down
Inlet
Neoprene Gasket
Air Relief
apparatus.
Flow
Control
Separation
Chamber
Outlet
Static
Water Line
Removable
Baffles
Figure 1
Overview
Smith GT Series Semi-Automatic Draw-off
Grease Interceptors offer the same
intercepting efficiency as the Traditional
manually cleaned models, but minimize the
effort involved in the unsanitary and
undesirable job of removing the accumulated
grease manually.
The Semi-Automatic Draw-off
Interceptor eliminates:
Cover removal and
Manually removing accumulated
grease.
Since cleaning a GT interceptor is simple,
fast and efficient, maintenance personnel
will more likely follow the regular cleaning
schedule. This is a distinct advantage over
the Traditional units which are frequently
left unattended. The Semi-Automatic
Draw-off Grease Interceptors are
designed for floor mount installation.
Grease Accumulating
Cone (C)
G-Cleanout
GT Series Semi-Automatic
Draw-Off Grease Interceptor Guide
Specification
Line Shut-off
Valve (A)
OUTLET
INLET
Air Relief
Static Water
Line
Removal
Baffles
Separation Chamber
Draw-Off
Valve (B)
Speciality Interceptors
Our full line of interceptors are
designed for adaptability, conformance
to code, ease of installation, and
maximum performance efficiency.
Some of the speciality interceptors
available from Jay R. Smith Mfg. Co.:
Overview
When a job specification or construction
project requires an interceptor to do more
than just prevent fat, oil, and grease (FOG)
from entering the citys sanitary sewer
system, Jay R. Smith Mfg. Co. offers a variety
of interceptors to meet your specific needs
from the innovative Remediator
Grease Treatment System, as well as a variety
of specialty interceptors.
Speciality Engineering
For a complete line of specialty interceptors,
look to Jay R. Smith Mfg. Co. Our in-house
staff of engineers possess the technical
knowledge to confer with engineers and
contractors to design an interceptor to meet
a special application, product modification,
or installation need. We look forward to the
challenge of designing and manufacturing
special products which solve our customers
needs. No cookie cutter approach here, our
designs are customer specified to get the job
done.
Lift Ring
OUTLET
INLET
Static
Water
Line
Suggested Piping
Arrangement (By Others)
Removable Stainless
Steel Mesh Bucket
4 7 10
4 7 10
.25 .44 .63
15 20 25 35 50
15 20 25 35 50
.95 1.26 1.58 2.20 3.16
8 14 20 30 40 50 70 100
3.6 6.4 9.1 13.6 18.2 22.7 31.8 45.4
Formula
Determine cubic content of
fixture by multiplying
length X Width X depth.
Example
A sink 48 long by 24
wide by 12 deep. Cubic
content 48 X 24 X
12=13,824 cubic inches
Contents in gallons
13,824/231 = 59.8 gallons
Flow rate =
Actual
Drainage Load
Drainage Period
5
4.2
16 X 14 X 8
5.8
20 X 18 X 8
9.4
10
18 X 16 X 8
15.0
15
10
20 X 18 X 8
18.7
20
10
30 X 20 X 8
15.5
20
10
24 X 20 X 12
18.7
20
10
22 X 20 X 8
23.0
25
15
22 X 20 X 12
34.0
36
20
24 X 24 X 12
44.9
50
25
GPM
Equivalent
PDI
Size Grease Interceptor
1-1/4
1-1/2
2
2-1/2
3
4
1
2
3
4
5
6
7.5
15.0
22.0
30.0
37.5
45.0
10
15
25
35
50
50
TABLE 5
Sizing Considerations
Size Symbols
It has been determined through the testing
and rating procedure that eight (8)
different sized grease interceptors are
required for normal domestic, commercial,
and institutional installations. These sizes
are based on certification standard flow
Selection
Table 4 is included as a selection chart for
standard PDI Certified grease interceptors
applicable to various size fixtures commonly
used in domestic, commercial and
institutional installations. The selections
listed are based on the sizing formula
covered in Table 3.
Dishwashers
A separate grease interceptor is recommended for each commercial dishwasher.
The size of the interceptor is determined by
the GPM discharge rate of the dishwasher.
Select proper interceptor of equivalent or
next higher rate from Table 2.
Multiple Fixtures
When multiple fixtures are served by a
single interceptor, calculate the total
capacity of all fixtures, establish the
maximum number of fixtures that may
be drained simultaneously and apply this
factor to the total capacity to determine
the maximum simultaneous capacity.
Then proceed with sizing and selection of
interceptor using sizing formula, Table 3.
TABLE 1: CERTIFICATION STANDARD FLOW RATES AND GREASE RETENTION CAPACITY RATINGS
FOR GREASE INTERCEPTORS
Grease Retention
Capacity Rating
Flow Rate
(GPM)
For Small
Domestic Use
Sizing Procedure
For Large
Domestic,
Commercial, and
Institutional Use
(L/s)
4
7
0.25
0.44
10
15
20
25
35
50
0.63
0.95
1.26
1.58
2.20
3.16
(Pounds)
8
14
20
30
40
50
70
100
(kg)
3.6
6.4
9.1
13.6
18.2
22.7
31.8
45.4
Recommended Maximum
Capacity of Fixtures Connected
Connected to Interceptors
(Gallons)
10.0
17.5
25.0
37.5
50.0
62.5
87.5
125.0