Sunteți pe pagina 1din 41
Cc) MGMP Me > ELECTRICAL INSTALLATIONS Me.G100.P Me.G200.P MODIFIED GUARANTEED MAXIMUM PRICE PACKAGE ELECTRICAL INSTALLATION GENERAL ‘The Specification for electrical installation shall include the specification clauses of the General Specification Worksection ELE and the Project Specific Specification (PSS) clauses with prefix of “ELE” stated in this Specification. This part of specifications shall be read in conjunction with Appendix V to the Special Conditions of Contract, Special Conditions of Tender and the General Specifications Worksection ELE in respect of Materials, Equipments, System Requirement, Installation, Testing & Commissioning and Maintenance. Refer to PRE.B2.01 1 P. for the total scope of MGMP packages, THE WORKS ELE1.2.010.P SITE OF THE WORKS “The site of the Works is at Eastem Harbour Crossing Site Phase 4, a public housing estate of the Hong Kong Housing Authority in Yau Tong. ELE12.020.P SCOPE OF THE WORKS 20050054 1. The works to be carried out under this MGMP Package shall be referred to as “Mle” stated at PRE.B2.01 1.P and shall include the whole of the materials and abour necessary for the complete electrical installation and the maintenance of the same for twenty four (24) months following the certified completion date of the Works or any Sections) of the Works, for: a. Three 41 storey site specific blocks namely Block P, Q and R constituting the following major features: i) The ground floor, mezzanine and typical floors of Blocks P and Block Q are identically handed except the truncated floors from F35 to the roof at Wing D of Block Q; ii) The typical floors of Block Q and Block R are identical except the truncated floors as mentioned above; iii) ‘The first domestic floor at Wing C of Block P & Q has been omitted to make way for the passage of an elevated walkway, iv) The first domestic floor at Wing'B of Block R has been omitted for a public passage at the ground floor, ¥) — Mezzanines are provided at all wings of Block P & Q Tinking the elevated walkway to create public open spaces and ventilation voids; b, MAC office on GIF at each of the Domestic Block; c. — Aneighboushood elderly centre (NEC) on GIF at wing B of block P and 4. Alift tower Link with bridge; fe. Refise collection Point (Subject to excision); £ Drainage reserve area; and PSS-Me- 1 MoM Me > ELECTRICAL INSTALLATIONS. & Associated external areas and walkways. all as shown on the Base Scheme Design Drawings and detailed in this Specification; 2. The electrical installation shall comprise the Electrical Power Distribution and Associated Systems, Security (SE) System, Lighting Installation, Mechanical Ventilation System, alll other equipment and systems itemised and described hereunder and detailed in this Specification and Base Scheme Design Drawings; and shall included all associated builder's works and necessary liaison/attendance with concemed parties and utility companies in relation to the satisfactory execution of the installation, Design development of lighting installations for folly of double deck walkway, covered walkway, linked bridge to lift tower, drainage reserve area, refuse collection area (subject to excision) and entrance fagade/portico of domestic blocks; design developments for the base scheme design, proposed alternative design or any requested GMP variations raised by the Contractor, the Sub-contractor herself or other GMP. sub-contractors and general co-ordination of design and installation works amongst different GMP sub-contractors. For the O avoidance of doubt, associated builder’s works refer to building works to be executed under this work package required for installing and completing the electrical installations. The associated builder’s works and attendances are outlined generally in sub-clause (4) below. Details of associated builder’s works shall be submitted for approval prior to commencement of work on site. 3. The complete installation shall mean, not only the major items of equipment and apparatus conveyed by this Specification, but all the incidental sundry components necessary for the complete execution of the works and for the proper operation of the installation with their labour charges, whether or not these sundry components are mentioned in detail in the tender documents. 4. Provision and construction of associated builder’s works and attendances, for Electrical Installation (including FTNS/CABDS/CCTVS Installation, Security Alarm/EAS/ Door Phone System Installation) shall include: a. Lamp pole foundations, concrete bases, beddings, footings, enclosure for housing power supply/control gears for street lightings, earth pits, chases, cable ducts, cable support brackets, luminaries fixings/supports/enclosures for controls, holes/openings through C) slab/wali/ocam, cable draw pits, cable trenches excavation, )) backfilling, hoisting beam, plinths, floating slabs in emergency generator Foom and similar associated builder's works required for ‘he installation; b. Cable duets, trench and draw pits in extemal areas for incoming supply cables of CLP Power and signal cables of TBS Operators from site boundary to transformer room and TBE room/duct room; all ducts which are not accessible shall be lubricated with graphite powder, Kept clean and complete with draw wires. Provide sealing ‘at duct ends and fire collar/stoplapproved fire resist ‘material across fire compartments; . Exhaust and ventilation air duct, louvers/gritles, volume control damper, filter, silencer, fire damper, access panel, supports and fixings; 4. Provision of necessary holes, chases, underground PVC or GI. duct, and making good thereafter, €. Touching up of plaster after wiring wor ‘Openings on slabs or walls or window glazing and mounting plate for mounting of roof extractors and/or exhaust fans; ) g. Fixtures/enclosures for mounting of external lighting and associated contral gears; 20050054 PSS-Me-2 MGMP ‘Me> ELECTRICAL INSTALLATIONS h. Painting of exposed metal parts and cables as directed by CM upon completion of the installation and before expiry of maintenance period; i, Liaise with CLP Power (HI) Limited for the installation; and j. Submit to the Contract Manager's Representative in the moming of every working day the daily labour strength report. Such report shall indicate the number of workers and their deployment on site on that day. Construction of transformer room, main switch room and meter rooms on ground floor, doors, rain guards, wall cow\/louvers for exhaust fan, air duct inside transformer rooms, cable trenches inside transformer/main switch rooms; cable tunnels from main switch room to ground floor switch rooms; TBE room/duct room, meter rooms, meter cupboard, doorphone and FTNS cupboard on typical floors ate provided by Main Contractor. SYSTEM/INSTALLATION REQUIREMENTS CONTRACT DOCUMENTATION ELE13.010P ELE13.030.2 20050054 DRAWINGS AND DOCUMENTS L ‘The Contractor’s attention is drawn to the latest revision of the following “Standard Drawing and Document” issued by the Housing Department which shall also be complied with where relevant. a, Standard Lighting Fitting Schedule. The aforesaid “Standard Drawings and Documents” will be available for inspection at the Building Services (New Works) Section, Housing Department during normal office hours upon application to the Contract Manager. . The drawings of electrical installation and the above “Standard Drawings and Documents” shall hereinafter be referred to as the Base Scheme Design Drawings listed in the Drawing Series for Electrical Installations in ‘Appendix B of the Tender Document. DEFINITIONS AND ABBREVIATIONS Jn this Specification the word "shall" is mandatory, the word "will" is informative, the word "should" is advisory and the Word "provide" means supply and fix, or supply and install. In addition the following words shall have meanings herein assigned: 1 2 3 "Authority" ‘means Hong Kong Housing Authority. "Indicated" means indicated elsewhere in the Specification or on the Drawings. "or Equal” or "or Similar" means having similar characteristics and Specification, as regards type of, construction, performance, general appearance and standard of quality of manufacture. "Drawing" ‘means the drawings referred to in the Specification and any modification of such drawings Approved by the Contract Manager and such other drawings as may be, from time to time, furnished or Approved "Standard Drawings" PSS-Me-3

S-ar putea să vă placă și