Sunteți pe pagina 1din 11

Daikin Air Conditioning

Daikin air conditioners for shops,


restaurants and offices.

4-WAY BLOW CEILING


MOUNTED CASSETTE
(600x600mm)

UK Price List Attached

Correct as of 13/04/08

Please check
http://global-cooling.co.uk
For the latest information

For more information about this range of air conditioning systems


http://global-cooling.co.uk/airconditioning/air-conditioning-brands/daikin-air-conditioning/daikin-airconditioning/

If you need any help please call us on 01200 428888


Or use Live Chat

UK Price List Attached


Please check the here for latest specifications and prices.

Global Cooling Air Conditioning UK


www.global-cooling.co.uk
Upbrooks Industrial Estate
Clitheroe, Lancashire
BB7 1PL, UK

UK Air Conditioning Online Shop - http://global-cooling.com/

Air Conditioning Forum - http://air-conditioning-forum.global-cooling.co.uk/


MOV91822_EPLE05-27A

Daikin air conditioners


f o r s h o p s , re s t a u r a n t s a n d o ff i c e s

4-WAY B LO W C E I LI N G M O U NTE D C A S S ET TE (600x600mm)

w w w. d a i k i n e u ro p e . c o m

FFQ-B7

Cyan Magenta Yellow Black


MOV91822_EPLE05-27A

The ceiling mounted 4-way blow cassette is specially designed for use in false ceilings.
The greater part of the unit integrates perfectly with 600x600mm ceiling tiles. Only
the slim decoration panel remains visible. As their name suggests, these units can
discharge air in any of 4 directions.
These cassettes are equipped with a special draught prevention and anti-ceiling
soiling technology.

COMFORT

• You have the choice of 3 auto-swing positions for maximum comfort: standard, draught
prevention or ceiling soiling prevention. Since the flaps can move to a 0° position, you
will experience virtually no draught!

Ceiling void Ceiling void Ceiling void


is 295mm is 295mm is 295mm
0° 0°
25°
35°
60° 60°

Standard setting: Draught prevention: Ceiling soiling prevention:


Auto swing between 0° to 60° Auto swing between 0° and 35° Auto swing between 25° and 60°

• You have the choice of 2 fan speeds to select: high or low. A high fan speed provides
maximum reach while a low fan speed minimizes drafts.

• The indoor unit is extremely quiet in operation. The sound levels are as low as 24.5dB (A),
comparable to rustling leaves.

• Daikin’s special dry programme reduces humidity in the room without variations in
room temperature.

• The indoor unit contains an air filter which removes microscopic particles and dust.

Cyan Magenta Yellow Black


MOV91822_EPLE05-27A

FLEXIBLE INSTALLATION AND EASY TO USE AND MAINTAIN

• The indoor unit can easily be installed into false ceilings (minimum height of 295mm).

• Due to the compact casing, it matches standard architectural modules of 600 x 600mm
- ceiling tile cutting is no longer necessary.

• When the ceiling void is too small, a panel spacer can be used to cover the space
between the ceiling and decoration panel.

• It is possible to shut one or 2 flaps off enabling the unit to be installed in the middle
of the room, in a corner or in a small room.

2-Way blow 3-Way blow 4-Way blow

• Since the switch box is located within the unit, it is easy to access from below for
maintenance without removing ceiling tiles.

• The outdoor unit can be installed on a roof or terrace or placed against an outside wall.

• Special anti-corrosion treatment of the outdoor unit’s heat exchanger fin, gives
greater resistance against acid rain and salt corrosion. Additional resistance is provided
by a rustproof steel sheet on the underside of the unit.

An anti-corrosion heat
exchanger cutaway view

Hydrophilic film
Aluminium
Heat exchanger
Corrosion-resistant
Acrylic resin

• Daikin remote controls give you easy control at your fingertips.

• The wired remote control provides you with a schedule timer, enabling the air
conditioning to be programmed daily or weekly.

• The optional remote ON/OFF enables you to start/stop the air conditioning from a
mobile phone via a telephone remote control (field supply).
The optional forced OFF enables you switch off the unit automatically. E.g. when a
window is opened, the unit switches off.

Infrared remote
control (Optional)

Wired remote
control (Optional)

Cyan Magenta Yellow Black


MOV91822_EPLE05-27A

ENERGY EFFICIENT

• Energy label: up to class B

• Inverter technology
Improved energy efficiency:
The use of integrated inverter control ensures maximum energy efficiency by supplying
only the required heating or cooling load where a standard non inverter unit would supply
maximum load in an on/off regime.

Keeps temperature stable

Smaller
Slow start-up temperature
difference

Large temperature
difference

Startup time reduced


Set point by about 1/3
Non inverter es
cycl
air conditioning
nd cold
a
hot
eats
Rep

Inverter air conditioning

Improved comfort:
The rapid start up time provided by the inverter increases comfort by reducing the lead
time in obtaining the required indoor temperature. As soon as the required temperature
is reached, the inverter unit continuously scans the room for small changes and adjusts
the room temperature in seconds, thereby increasing comfort once again.

• The ‘home leave’ operation button prevents large temperature differences by


continuously operating at a minimum (heating mode) or maximum (cooling mode) preset
level while you’re out or sleeping. It also allows the indoor temperature to return quickly
to your favourite comfort level.

ONE PUSH While out of the home PUSH AGAIN

When you go out push When you return, you Push the “Home leave
the “Home leave will be welcomed by operation” button again,
operation” button, and a comfortable and the air conditioner
the air conditioner will air-conditioned room. will adjust capacity to
adjust capacity to reach the set temperature for
the preset temperature normal operation.
for “Home leave
operation”.

APPLICATION OPTIONS

• This model can be used for cooling only or heating.

• It is possible to use the indoor unit in pair (connecting one indoor to one outdoor), twin,
triple, double twin (connecting up to 4 indoors in the same room to a single outdoor)
and multi applications (connecting up to 9 units in several rooms to 1 outdoor unit).

Cyan Magenta Yellow Black


MOV91822_EPLE05-27A

Capacity and power input


COOLING ONLY - INVERTER CONTROLLED/NON INVERTER FFQ25B7V1B FFQ35B7V1B FFQ50B7V1B FFQ60B7V1B FFQ50B7V1B FFQ60B7V1B
(air cooled) RKS25DVMB RKS35DVMB RKS50BVMB9 RKS60BVMB9 RS50BVMB RS60BVMB
Cooling capacity min~nom~max kW 1.3~2.5~3.0 1.4~3.4~3.7 0.90~4.70~5.60 0.90~5.80~6.00 4.70 (nom) 5.80 (nom)
Nominal input min~nom~max kW 0.30~0.83~1.10 0.30~1.30~1.47 0.45~1.80~2.26 0.45~2.07~2.15 1.80 (nom) 2.07 (nom)
EER 3.01 2.62 2.61 2.80 2.61 2.80
Energy label B D D D D D
Annual energy consumption cooling kWh 415 650 900 1,035 900 1,035
HEAT PUMP - INVERTER CONTROLLED FFQ25B7V1B FFQ35B7V1B FFQ50B7V1B FFQ60B7V1B
(air cooled) RXS25DVMB RXS35DVMB RXS50BVMB RXS60BVMB
Cooling capacity min~nom~max kW 1.3~2.5~3.0 1.4~3.4~3.7 0.90~4.70~5.60 0.90~5.80~6.00
Heating capacity min~nom~max kW 1.3~3.2~4.5 1.4~4.5~5.0 0.90~5.50~7.00 0.90~7.00~8.00
Nominal input cooling min~nom~max kW 0.30~0.83~1.10 0.30~1.30~1.47 0.45~1.80~2.26 0.45~2.07~2.15
heating min~nom~max kW 0.29~0.935~1.75 0.29~1.60~1.80 0.45~1.96~2.78 0.45~2.49~2.92
EER 3.01 2.62 2.61 2.80
COP 3.42 2.81 2.81 2.81
Energy label cooling B D D D
heating B D D D
Annual energy consumption cooling kWh 415 650 900 1,035

Notes:
1) Energy label : scale from A (most efficient) to G (less efficient).
2) Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions)

MULTI - COOLING ONLY Max. n° Max. cooling Max. PI cooling


of indoor units capacities (kW) (kW)
4MKS58D 4 6.60 2.47
4MKS75D 4 9.27 3.71
4MKS90D 4 9.86 3.52
MULTI - HEAT PUMP Max. n° Max. cooling Max. PI cooling Max. heating Max. PI heating
of indoor units capacities (kW) (kW) capacities (kW) (kW)
2MXS52D* 2 6.50 2.69 7.34 2.42
3MXS52D* 3 6.50 2.69 7.34 2.42
4MXS68D* 4 8.68 3.69 10.64 3.41
4MXS80D* 4 9.49 3.34 11.00 3.52
SUPER MULTI PLUS - HEAT PUMP Max. n° Max. cooling Max. PI cooling Max. heating Max. PI heating
of indoor units capacities (kW) (kW) capacities (kW) (kW)
RMXS112D* 7 11.20 3.57 12.50 4.01
RMXS140D* 8 14.00 5.23 16.00 5.31
RMXS160D* 9 15.50 5.55 17.50 5.56
Notes:
- For more detailed information about specifications, capacities, power input, energy labelling and annual energy consumption, please refer to our Multi Model Catalogue/Super Multi Plus Catalogue or check
with your local dealer.
* At least 2 indoor units should be connected to a Multi outdoor unit.

TWIN/TRIPLE/DOUBLE TWIN APPLICATION FFQ35B7V1B FFQ50B7V1B FFQ60B7V1B


RR/RQ71 2
RR/RQ100 3 2
RR/RQ125 3 2
RZQ71 2
RZQ100 3 2
RZQ125 4 3 2
RZQ140 4 3
RZQ200 4 3
RZQ250 4

Cyan Magenta Yellow Black


MOV91822_EPLE05-27A

Specifications indoor units


COOLING ONLY/HEAT PUMP FFQ25B7V1B FFQ35B7V1B FFQ50B7V1B FFQ60B7V1B
Dimensions HxWxD unit mm 286x575x575
decoration panel mm 55x700x700
Weight unit kg 17.5
decoration panel kg 2.7
Colour decoration panel White (RAL9010)
Air flow rate H/L m3/min 9/6.5 10/6.5 12/8 15/10
Fan speed 2 steps
Sound pressure level H/L dB(A) 29.5/24.5 32/25 36/27 41/32
Sound power level H dB(A) 46.5 49 53 58
Piping connections liquid mm ø6.4
gas mm ø9.5 ø12.7
drain (VP25) ID mm ø20
OD mm ø26
Heat insulation Both liquid and gas pipes

Indoor unit: FFQ-B

FFQ25,35,50,60B7V1B

Cyan Magenta Yellow Black


MOV91822_EPLE05-27A

Specifications outdoor units


COOLING ONLY RKS25DVMB RKS35DVMB RKS50BVMB9 RKS60BVMB9 RS50BVMB RS60BVMB
Dimensions HxWxD mm 550x765x285 735x825x300 735x825x300
Weight kg 30 32 49 53 49 53
Casing colour Ivory white Ivory white
Sound pressure level H/L dB(A) 46/43 47/44 47/- 49/- 47/- 49/-
Sound power level H dB(A) 61 62 63 64 63 64
Compressor hermetically sealed swing type Swing compressor
Refrigerant type R-410A R-410A
Refrigerant charge kg/m 0.02 (for piping length exceeding 10m) 0.02 (piping length>10m)
Maximum piping length m 20 30 30
Maximum level difference m 15 20 20
Operation range from ~ to °CDB -10~46 -10(-15*)~46 +10~46
HEAT PUMP RXS25DVMB RXS35DVMB RXS50BVMB RXS60BVMB
Dimensions HxWxD mm 550x765x285 735x825x300
Weight kg 30 32 49 53
Casing colour Ivory white
Sound pressure level cooling H/L dB(A) 46/43 47/44 47/- 49/-
heating H/L dB(A) 47/44 48/45 48/- 49/-
Sound power level cooling H dB(A) 61 62 63 64
heating H dB(A) 62 63 64 64
Compressor hermetically sealed swing type
Refrigerant type R-410A
Refrigerant charge kg/m 0.02 (for piping length exceeding 10m)
Maximum piping length m 20 30
Maximum level difference m 15 20
Operation range cooling from ~ to °CDB -10~46
heating from ~ to °CWB -15~20
* Possibility to extend the operation range down to -15°C by turning ON the switch on the outdoor unit PCB. In this case, the unit will stop operation at -20°C or lower and will recover when temperature rises again.
- Information is not available.

Cyan Magenta Yellow Black


MOV91822_EPLE05-27A

Accessories: control systems


INDOOR UNITS FFQ25B FFQ35B FFQ50B FFQ60B
Wired remote control BRC1D528
Infrared remote control cooling only BRC7EA531W7
heat pump BRC7EA530W7
Centralised remote control DCS302CA51
Unified ON/OFF control DCS301BA51
Schedule timer DST301BA51
Adapter for wiring (1) KRP1BA57
Adapter for external ON/OFF and monitoring (1) KRP4AA53
Adapter for wiring (hour meter) (2) EKRP1B2A
Remote sensor KRCS01-1A
Installation box for adapter PCB KRP1BA101
Interface adapter for Sky Air DTA112BA51
Remote ON/OFF, forced OFF EKROROA
(1) Installation box for adapter PCB (KRP1B101) is necessary.
(2) Possibility to connect an hour meter (field supply). This part should not be installed inside the equipment.

Accessories
INDOOR UNITS FFQ25B FFQ35B FFQ50B FFQ60B
Decoration panel BYFQ60BAW1
long-life filter KAFQ441BA60
Fresh air intake kit direct installation type KDDQ44XA60
Sealing member of air discharge outlet KDBHQ44BA60
Panel spacer KDBQ44BA60

Accessories
OUTDOOR UNITS RKS/RXS25D RKS/RXS35D RS/RKS/RXS50B RS/RKS/RXS60B
Air direction adjustment grille KRW937A4 KPW945AA4
Central drain plug KKP937AA4 - -
Notes:
1) V1 = 1~,230V,50Hz; VM = 1~, 220-240V/220-230V, 50Hz/60Hz; V3 = 1~, 230V, 50Hz
2) Nominal cooling capacities are based on: indoor temperature 27°CDB/19°CWB • outdoor temperature 35°CDB • refrigerant piping length 7.5m • level difference 0m.
3) Nominal heating capacities are based on: indoor temperature 20°CDB • outdoor temperature 7°CDB/6°CWB • refrigerant piping length 7.5m • level difference 0m.
4) Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
5) Units should be selected on nominal capacity. Max. capacity is limited to peak periods.
6) The sound pressure level is measured at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment.
7) The sound power level is an absolute value indicating the "power" which a sound source generates.

Daikin’s unique position as a manufacturer Daikin Europe N.V. is approved by LRQA for its “The present leaflet is drawn up by way of information only and
of air conditioning equipment, compressors Quality Management System in accordance with does not constitute an offer binding upon Daikin Europe N.V..
and refrigerants has led to its close the ISO9001 standard. Daikin Europe N.V. has compiled the content of this leaflet to
involvement in environmental issues. For ISO9001 pertains to quality assurance regarding the best of its knowledge. No express or implied warranty is
several years Daikin has had the intention to design, development, manufacturing as well as to given for the completeness, accuracy, reliability or fitness for
become a leader in the provision of services related to the product. particular purpose of its content and the products and services
environmental friendly products. This presented therein. Specifications are subject to change without
challenge demands the eco design and prior notice. Daikin Europe N.V. explicitly rejects any liability for
development of a wide range of products any direct or indirect damage, in the broadest sense, arising
and an energy management system; which from or related to the use and/or interpretation of this leaflet.
involves energy conservation and reduction ISO14001 assures an effective environmental All content is copyrighted by Daikin Europe N.V..”
of waste. management system in order to help protect human
health and the environment from the potential
impact of our activities, products and services and
to assist in maintaining and improving the quality
of the environment.
Daikin products are distributed by:

Daikin units comply with the European regulations


EPLE05-27A / CD / 09/05 / La Movida

that guarantee the safety of the product.

Daikin Europe NV participates in the Eurovent


Zandvoordestraat 300 Certification Programme for Air Conditioners (AC),
Liquid Chilling Packages (LCP) and Fan Coil Units
B-8400 Oostende, Belgium (FC); the certified data of certified models are listed
in the Eurovent Directory. Multi units are Eurovent
www.daikineurope.com certified for combinations up to 2 indoor units.

Cyan Magenta Yellow Black


Global Cooling Air Conditioning UK Prices*
Daikin 600mm x 600mm Cassette Type Air Conditioning – COOLING ONLY TYPES
UK UK UK
Features Nom cooling Nom heating - - Inter wires - - Max pipe - - - - Price
Cool Cool Heat
T/C S/C Run Max min kg
Daikin Inverter Models Cooling Only Types Min~norm~max Min~norm~max kw Fuse connecting Liquid Suction separation kg out Exc Vat
kw kw amps level amb in
Buy it
FFQ25B+RKS25F 1.3~2.4~3.0 n/a 2.5 1.9 n/a 3.8 15 3+e 1/4" 3/8" 25 15 -10 12 37 £957.68
online
Buy it
FFQ35B+RKS35F 1.4~3.4~3.8 n/a 3.4 2.3 n/a 5.5 15 3+e 1/4" 3/8" 25 15 -10 12 37 £1087.63
online
Buy it
FFQ50B+RKS50F 1.7~4.7~5.6 n/a 5.0 3.5 n/a 7.3 20 3+e 1/4" 1/2" 30 20 -10 12 49 £1272.18
online
Buy it
FFQ60B+RKS60F 1.7~5.8~6.0 n/a 5.8 4.2 n/a 9.3 20 3+e 1/4" 1/2" 30 20 -10 12 53 £1368.27
online

*Please check the following page for latest specifications and prices for this range of air conditioning systems.
http://global-cooling.co.uk/airconditioning/air-conditioning-brands/daikin-air-conditioning/daikin-airconditioning/

Please see the next page for heat pump type prices.
Global Cooling Air Conditioning UK Prices*
Daikin 600mm x 600mm Cassette Type Air Conditioning – HEAT PUMP TYPES
UK UK UK
Features Nom cooling Nom heating - - Inter wires - - Max pipe - - - - Price
Cool Cool Heat
T/C S/C Run Max min kg
Daikin Inverter Models Heat Pump Types Min~norm~max Min~norm~max kw Fuse connecting Liquid Suction Separation kg out Exc Vat
kw kw amps level amb in
Buy it
FFQ25B+RXS25F 1.3~2.5~3.0 1.3~3.2~4.5 2.5 1.9 2.5 3.8 15 3+e 1/4" 3/8" 25 15 -10 12 37 £1016.65
online
Buy it
FFQ35B+RXS35F 1.4~3.4~3.7 1.4~4.0~5.0 3.4 2.3 3.0 5.5 15 3+e 1/4" 3/8" 25 15 -10 12 37 £1153.15
online
Buy it
FFQ50B+RXS50G 1.7~4.7~5.6 1.7~5.5~7.0 4.7 3.5 4.0 7.3 20 3+e 1/4" 1/2" 30 20 -10 12 49 £1367.18
online
Buy it
FFQ60B+RXS60F 1.7~5.8~6.0 1.7~7.0~8.0 5.8 4.2 5.1 9.3 20 3+e 1/4" 1/2" 30 20 -10 12 53 £1463.28
online

                                                    

*Please check the following page for latest specifications and prices for this range of air conditioning systems.
http://global-cooling.co.uk/airconditioning/air-conditioning-brands/daikin-air-conditioning/daikin-airconditioning/

If you need any help please call us on 01200 428888 or use Live Chat

S-ar putea să vă placă și