Documente Academic
Documente Profesional
Documente Cultură
0009-6069
<AE>
T-16-16
COPIER > ADJUST > AE
Level 3 item
Description
Level
AE-TBL
If you have initialized the RAM on the reader controller PCB, enter the
value indicated on the service label.
<ADJ-XY>
T-16-17
COPIER > ADJUST > ADJ-XY
Level 3 item
Description
Level
ADJ-Y
ADJ-S
Use it to adjust the point at which data is collected for shading using
the standard white plate.
adjustment range: 20 to 200 (default: 50)
16-50
Chapter 16
Description
Level
ADJ-Y-DF
STRD_POS
Use it to adjust the CCD read position for DF stream reading mode.
adjustment range: 1 to 200 (default: 100)
<CCD>
T-16-18
COPIER > ADJUST > CCD
Level 3 item
Description
Level
DFTAR-G
Use it to adjust the shading target value for green for DF mode.
adjustment range: 1 to 2047 (default: 1189)
<LASER>
T-16-19
COPIER > ADJUST > LASER
Level 3 item
Description
PVE-OFST
POWER
Level
1
16-51
Chapter 16
<DEVELOP>
T-16-20
COPIER > ADJUST > DEVELOP
Level 3 item
BIAS
HVT-DE
Description
Level
Use it to enter the offset value for the high-voltage D/A output for the DC
D-HV-DE
controller PCB.
developing assembly.
<DENS>
T-16-21
COPIER > ADJUST > DENS
Level 3 item
Description
DENS-ADJ
Level
16-52
Chapter 16
<BLANK>
T-16-22
COPIER > ADJUST > BLANK
Level 3 item
Description
Level
BLANK-T
If you have initialized the RAM on the DC controller PCB or replaced the
PCB, enter the value indicated on the service label.
BLANK-B
<V-CONT>
T-16-23
COPIER > ADJUST > V-CONT
Level 3 item
Description
EPOTOFST
VL-OFST
VD-OFST
DE-OFS-P
Use it to enter the offset value of the back contrast for printer images.
adjustment range: -50 to 50 (default: 0)
VD-OFS-P
DE-OFST
Level
1
16-53
Chapter 16
Description
Level
VL-OFS-P
<HV-PRI>
T-16-24
COPIER > ADJUST > HV-PRI
Level 3 item
Description
Level
PRIMARY
<HV-TR>
T-16-25
COPIER > ADJUST > HV-TR
Level 3 item
TR-N1
Description
Level
Use it to adjust the output level of the 1st side of plain paper for an N/N
environment.
Use it to adjust the output level of the 2nd side for an N/N environment.
adjustment range: 100p to 400 (default: 310)
PRE-TR
HVT-TR
Use it to enter the transfer charging assembly high-voltage offset value for
the high-voltage unit.
16-54
Chapter 16
Description
Level
D-PRE-TR
Use it to enter the transfer charging assembly high-voltage offset value for
the DC controller PCB.
<HV-SP>
T-16-26
COPIER > ADJUST > HV-SP
Level 3 item
Description
SP-N1
Use it to adjust the output level for the 1st side of plain paper for an N/N
environment.
Level
Use it to adjust the output level for the 2nd side of plain paper for an N/
N environment.
16-55
Chapter 16
<FEED-ADJ>
T-16-27
COPIER > ADJUST > FEED-ADJ
Level 3 item
Description
Level
<CST-ADJ>
T-16-28
COPIER > ADJUST > CST-ADJ
Level 3 item
Description
C3-STMTR
Use it to enter the paper width basic value for cassette 3 (STMTR).
adjustment range: 0 to 255
C3-A4R
Use it to enter the paper width basic value for cassette 3 (A4R).
adjustment range: 0 to 255
C4-STMTR
Use it to enter the paper width basic value for cassette 4 (STMTR).
adjustment range: 0 to 255
C4-A4R
Use it to enter the paper width basic value for cassette 4 (A4R).
adjustment range: 0 to 255
MF-A4R
Use it to enter the paper width basic value for the manual feed tray (A4R).
adjustment range: 0 to 255
MF-A6R
Use it to enter the paper width basic value for the manual feed tray (A6R).
adjustment range: 0 to 255
16-56
Level
1
Chapter 16
Description
Level
MF-A4
Use it to enter the paper width basic value for the manual feed tray (A4).
adjustment range: 0 to 255
C3-LVOL
C3-HVOL
C4-LVOL
C4-HVOL
<MISC>
T-16-29
COPIER > ADJUST > MISC
Level 3 item
Description
ATM
Level
installation.
settings range: 0 to 2 (default: 0)
0: 1 to 0.75 atm (up to elevation of 2500 m)