Sunteți pe pagina 1din 8

Chapter 16

16.4 ADJUSTAdjustment Mode


16.4.1 COPIER
16.4.1.1 COPIER List

0009-6069

<AE>
T-16-16
COPIER > ADJUST > AE
Level 3 item

Description

Level

AE-TBL

adjustment range: 1 to 9 (default: 5)


- to obtain darker characters, increase the setting.
- to obtain lighter characters, decrease the setting.

If you have initialized the RAM on the reader controller PCB, enter the
value indicated on the service label.

<ADJ-XY>
T-16-17
COPIER > ADJUST > ADJ-XY
Level 3 item

Description

Level

Use it to adjust the image read start position.


- If you have initialized the RAM on the reader controller PCB or replaced the PCB, enter the value indicated on
the service label.
- If you have changed the setting of this item, record the new setting on the service label.
ADJ-X

Use it to adjust the image read start position (X direction).


adjustment range: 1 to 100 (default: 20)

ADJ-Y

Use it to adjust the image read start position (Y direction).


adjustment range: 47 to 131 (default: 90)

ADJ-S

Use it to adjust the point at which data is collected for shading using
the standard white plate.
adjustment range: 20 to 200 (default: 50)

16-50

Chapter 16

COPIER > ADJUST > ADJ-XY


Level 3 item

Description

Level

ADJ-Y-DF

Use it to adjust the main scanning position for feeder mode.


adjustment range: 21 to 106 (default: 53)

STRD_POS

Use it to adjust the CCD read position for DF stream reading mode.
adjustment range: 1 to 200 (default: 100)

<CCD>
T-16-18
COPIER > ADJUST > CCD
Level 3 item

Description

Level

DFTAR-G

Use it to adjust the shading target value for green for DF mode.
adjustment range: 1 to 2047 (default: 1189)

<LASER>
T-16-19
COPIER > ADJUST > LASER
Level 3 item

Description

PVE-OFST

Use it to adjust the laser write start position.


adjustment range: -300 to 300

POWER

Use it to adjust the laser power (for non-potential control).


adjustment range: 0 to 255

Level
1

16-51

Chapter 16

<DEVELOP>
T-16-20
COPIER > ADJUST > DEVELOP
Level 3 item
BIAS

HVT-DE

Description

Level

Use it to adjust the developing bias (for non-potential control).


adjustment range: 0 to 600 (default: 180)
Use it to enter an offset value for the high-voltage unit.
adjustment range: -100 to 100 (default: 0)

Use it to enter the offset value for the high-voltage D/A output for the DC
D-HV-DE

controller PCB.

adjustment range: -50 to 50 (default: 0)


Use it to adjust the toner supply distribution (axial direction) for the
TSPLY-ADJ

developing assembly.

adjustment range: 1 to 5 (default: 3)

<DENS>
T-16-21
COPIER > ADJUST > DENS
Level 3 item

Description

DENS-ADJ

Use it to adjust the density of images (copier/printer).

Level

Use it to correct the F-value table in the event of fading in a high-density


area or fogging in an image.
adjustment range: 1 to 9 (default: 5)
- to decrease fading, increase the value.
- to decrease fogging, decrease the value.
If you have initialized the RAM on the DC controller PCB, enter the value
indicated on the service label.

16-52

Chapter 16

<BLANK>
T-16-22
COPIER > ADJUST > BLANK
Level 3 item

Description

Level

BLANK-T

Use it to enter the image leading edge non-image width.


adjustment range: 1 to 500 (default: 0)

If you have initialized the RAM on the DC controller PCB or replaced the
PCB, enter the value indicated on the service label.
BLANK-B

Use it to enter the image trailing edge non-image width.


adjustment range: 0 to 2362 (default: 0)
If you have initialized the RAM on the DC controller PCB or replaced the

PCB, enter the value indicated on the service label.

<V-CONT>
T-16-23
COPIER > ADJUST > V-CONT
Level 3 item

Description

EPOTOFST

Use it to enter the potential offset value.


adjustment range: 0 to 255 (default: 0)

VL-OFST

Use it to enter the light-area target potential offset adjustment value.


adjustment range: -5 to 5 (default: 0)

VD-OFST

Use it to enter the dark-area target potential offset adjustment value.


adjustment range: -5 to 5 (default: 0)

DE-OFS-P

Use it to enter the offset value of the back contrast for printer images.
adjustment range: -50 to 50 (default: 0)

VD-OFS-P

Use it to enter the target VD offset value for printer images.


adjustment range: -5 to 5 (default: 0)

DE-OFST

Use it to enter the target D offset value for copier images.


adjustment range: -50 to 50 (default: 0)

Level
1

16-53

Chapter 16

COPIER > ADJUST > V-CONT


Level 3 item

Description

Level

VL-OFS-P

Use it to enter the target VL offset value for printer images.


adjustment range: -50 to 50 (default: 0)

<HV-PRI>
T-16-24
COPIER > ADJUST > HV-PRI
Level 3 item

Description

Level

PRIMARY

Use it to enter the current setting of the primary charging assembly.


settings range: 0 to 1400 (default: 771)

<HV-TR>
T-16-25
COPIER > ADJUST > HV-TR
Level 3 item
TR-N1

Description

Level

Use it to adjust the output level of the 1st side of plain paper for an N/N
environment.

adjustment range: 100 to 400 (default: 380)


TR-N2

Use it to adjust the output level of the 2nd side for an N/N environment.
adjustment range: 100p to 400 (default: 310)

PRE-TR

Use it to adjust the current level of the pre-transfer charging assembly.


adjustment range: -300 to 0 (default: 220)

HVT-TR

Use it to enter the transfer charging assembly high-voltage offset value for
the high-voltage unit.

adjustment range: -100 to 100 (default: 0)


H-PRE-TR

Use it to enter the pre-transfer charging assembly high-voltage offset value


for the high-voltage unit.
adjustment range: -100 to 100 (default: 0)

16-54

Chapter 16

COPIER > ADJUST > HV-TR


Level 3 item

Description

Level

D-PRE-TR

Use it to enter the pre-transfer charging assembly high-voltage offset value


for the DC controller PCB.

adjustment range: -50 to 50 (default: 0)


D-HV-TR

Use it to enter the transfer charging assembly high-voltage offset value for
the DC controller PCB.

adjustment range: -50 to 50 (default: 0)

<HV-SP>
T-16-26
COPIER > ADJUST > HV-SP
Level 3 item

Description

SP-N1

Use it to adjust the output level for the 1st side of plain paper for an N/N
environment.

Level

adjustment range: -500 to 100 (default: -190)


SP-N2

Use it to adjust the output level for the 2nd side of plain paper for an N/
N environment.

adjustment range: -500 to 100 (default: -170)


HVT-SP

Use it to enter the separation charging assembly high-voltage offset level


for the high-voltage unit.

adjustment range: -100 to 100


D-HV-SP

Use it to enter the separation charging assembly high-voltage offset value


for the DC controller PCB.

adjustment range: -50 to 50

16-55

Chapter 16

<FEED-ADJ>
T-16-27
COPIER > ADJUST > FEED-ADJ
Level 3 item

Description

Level

Use it to adjust the leading edge registration.


REGIST

adjustment range: -50 to 50

Use it to adjust the horizontal registration for duplex mode.


ADJ-REFE

adjustment range: -50 to 50

Use it to adjust the registration for manual pickup.


RG-MF

adjustment range: -50 to 50

<CST-ADJ>
T-16-28
COPIER > ADJUST > CST-ADJ
Level 3 item

Description

C3-STMTR

Use it to enter the paper width basic value for cassette 3 (STMTR).
adjustment range: 0 to 255

C3-A4R

Use it to enter the paper width basic value for cassette 3 (A4R).
adjustment range: 0 to 255

C4-STMTR

Use it to enter the paper width basic value for cassette 4 (STMTR).
adjustment range: 0 to 255

C4-A4R

Use it to enter the paper width basic value for cassette 4 (A4R).
adjustment range: 0 to 255

MF-A4R

Use it to enter the paper width basic value for the manual feed tray (A4R).
adjustment range: 0 to 255

MF-A6R

Use it to enter the paper width basic value for the manual feed tray (A6R).
adjustment range: 0 to 255

16-56

Level
1

Chapter 16

COPIER > ADJUST > CST-ADJ


Level 3 item

Description

Level

MF-A4

Use it to enter the paper width basic value for the manual feed tray (A4).
adjustment range: 0 to 255

C3-LVOL

Use it to enter the capacity of the cassette 3 (50 sheets).


adjustment range: 0 to 255

C3-HVOL

Use it to enter the capacity of the cassette 3 (275 sheets).


adjustment range: 0 to 255

C4-LVOL

Use it to enter the capacity of the cassette 4 (50 sheets).


adjustment range: 0 to 255

C4-HVOL

Use it to adjust the capacity of the cassette 4 (275 sheets).


adjustment range: 0 to 255

<MISC>
T-16-29
COPIER > ADJUST > MISC
Level 3 item

Description

ATM

Use it to make settings related to the atmospheric pressure of the site of

Level

installation.
settings range: 0 to 2 (default: 0)
0: 1 to 0.75 atm (up to elevation of 2500 m)

1: 0.75 to 0.70 atm (elevation between 2500 and 300 m)


2: 0.70 to 0.65 atm (elevation between 300 and 3500 m)

16-57