Prctica #5: Medicin de

Temperatura.
Luis Bazurto Mosquera, Par: 107
Laboratorio de Instrumentacin Bsica, Facultad de
Ingeniera en Mecnica (FIMCP), ESPOL, Guayaquil,
Ecuador.
ABSTRACT: The practice performed in the
laboratory of thermofluids aimed, know the
temperature of a substance by different types of
measuring instruments as a type k thermocouple,
thermistor, bimetal thermometer, thermopile type T
and a glass thermometer which had to give as results
for each measure a similar measure in order to
perform the calibration curve relative to the
standard instrument to practice k type
thermocouple was chosen. The few which gave
similar results because to make the measurement of
the substance in this case was water, the temperature
is not completely homogeneous due to the bottom
portion had higher temperature than other parts of
the surface.
RESUMEN: La prctica realizada en el laboratorio de
termofluidos tuvo como objetivo, conocer la
temperatura de una sustancia por medio de diferentes
tipos de instrumentos de medicin como una
termocupla tipo k, termistor, termmetro bimetlico,
termopila tipo T y un termmetro de vidrio la cual tena
que dar como resultados para cada medida una
medicin parecida, para as realizar la curva de
calibracin respecto al instrumento patrn que esta
prctica se eligi la termocupla tipo k. La cuales dieron
resultados pocos parecidos debido a que al realizar la
nueva medicin de la sustancia que en este caso fue
agua, la temperatura no es totalmente homognea
debido en que la parte del fondo tenia mayor
temperatura que otras partes de la superficie.
Palabras claves- termocupla tipo k, termistor,
termmetro bimetlico, termopila tipo T.
I.
INTRODUCCIN
TERMOCUPLA TIPO K
Las termocuplas es un sensor para la medicin
de temperatura que ms se usa industrialmente, est
constituida de dos alambres de diferentes material
unidos en un extremo que al aplicar temperatura se
genera un voltaje muy pequeo el cual aumenta con la
temperatura. La termocupla tipo K usa alambres NiCr y
NiAl. [1]

TERMISTOR
Los termistores son sensores de temperatura resistivos
donde el resistor cambia de acuerdo a las variaciones de
temperatura, existen lo termistores cuya resistencia
aumentan mientras aumenta la temperatura y los que
cuya resistencia disminuye mientras aumenta la
temperatura. [2]

TERMOMETRO BIMETALICO
Los termmetros bimetlicos estn constituidos
por un tubo de acero inoxidable en cuyo interior est
colocada una espiral helicoidal bimetlica. Dicha espiral
est soldada por un extremo a la parte inferior del tubo
y por otra a una varilla de transmisin, a su vez
conectada a una aguja indicadora.
Las variaciones de temperatura causan en el
bimetal una deformacin que, mediante la rotacin de la
varilla, se transmite a la aguja indicadora situada en la
esfera. [3]

TERMOPILA TIPO T
Son termocuplas conectadas en serie, de tal forma que
los voltajes se suman, con la cual teniendo suficientes
termocuplas y buen gradiente de temperatura es posible
obtener algunos voltios. [4]

II.

MATERIALES Y METODO

MATERIALES
Termmetro digital con termocupla tipo K
Termopila con junta tipo T

Termmetro bimetlico
Termmetro de vidrio
Termistor, Cole-Palmer, rango de -50C a 125C
Olla
Hornilla elctrica
Agua
PROCEDIMIENTO EXPERIMENTAL
1. Calentamos el agua del recipiente hasta alcanzar una
temperatura lo suficientemente alta.
2. Procedemos entonces a introducir los diferentes
instrumentos que vamos a utilizar y leemos las
temperaturas indicadas en los mismos.
3. Bajamos poco a poco la temperatura del agua del
recipiente agregndole agua fra y agitamos un poco
para homogenizarla y tomamos rpidamente las
lecturas para cada disminucin de temperatura.

GRAFICO 2. CURVA DE CALIBRACION 2.

III. RESULTADOS
Termmetro
vidrio (C)

TABLA I. DATOS RECOLECTADOS


Termmetro
Patrn
Termistor
bimetlico
Termocupla
(C)
(F)
tipo K (C)

Termopila
tipo T
(mV)

88

190

85,6

86,8

4,5

87

185

84,4

84,6

3,7

84

180

80,3

80

3,6

81

180

78,8

78,8

3,6

77

170

76

74

3,3

74

170

72,6

72,5

2,9

73

160

69

70,5

3,3

70

160

66,8

68,1

3,2

67

155

63,3

64,6

2,9

TABLA II. CONVERSION DE DATOS PARA GRAFICAS.


Termme
Termme
tro
tro vidrio
bimetlic
(C)
o (C)

GRAFICO 3. CURVA DE CALIBRACION 3.

Termist
or (C)

Termocu
pla tipo
K (C)

Termopila
tipo T (C)

87,77

85,6

86,8

85

87

85

84,4

84,6

70

84

82,22

80,3

80

69

81

82,22

78,8

78,8

68

77

76,66

76

74

63

74

76,66

72,6

72,5

66

73

71,11

69

70,5

63

70

71,11

66,8

68,1

60

67

68,33

63,3

64,6

66

88

GRAFICO 4. CURVA DE CALIBRACION 4


GRAFICO 1. CURVA DE CALIBRACION 1.

existen cierto margen de error debido a su uso y


deterioro.

V.
IV.

BIBLIOGRAFIA

DISCUSIN Y CONCLUSIONES

Realizada las mediciones y hechas las curvas de


calibracin se puede observar que en algunas medidas
no coinciden con mucha exactitud esto se debe a que el
agua no tena una temperatura homognea en todo su
volumen adems de que tambin ciertos instrumentos a
tener ya mucho tiempo de uso estos no estn totalmente
calibrados por lo que se pierde temperatura.

[1]

[2]

[3]

[4]

Como en el caso de la termopila al ser tener varias


puntas estas no estaban totalmente sumergidas por lo
que cuando se ponan en contacto con el aire o ms
mnimo afectaba a la medicin. Por lo tanto se concluye
que tambin al usar los instrumentos de medicin

A. C. &. Instrumentacion, Arian, [En lnea]. Available:


http://www.arian.cl/downloads/nt-002.pdf. [ltimo acceso: 11
Enero 2014].
medirtemperatura.com, medirtemperatura.com, [En lnea].
Available: http://medirtemperatura.com/termistor.php. [ltimo
acceso: 11 Enero 2015].
T. S. d. C.V., Termokew S.A. de C.V., [En lnea]. Available:
http://www.termokew.mx/termometros.php. [ltimo acceso: 11
Enero 2015].
R.
Garcia,
Sidweb,
[En
lnea].
Available:
https://www.sidweb.espol.edu.ec/courses/23592/wiki/8_1__me
dici%C3%B3n_de_temperatura. [ltimo acceso: 11 Enero
2015].

S-ar putea să vă placă și