MODEL 8100A
SPECIFICATION
MODEL 8100A FLAMA ARRESTER
Rev
Page : 1/4
Job
1 0 1
Date : 16.04.2009
8100A Series Flame Arresters are typically used on atmospheric tanks which contain
volatile liquids.
INTRODUCTION
As will all AKTEK products, every Model 8100A Series is factory
inspected to meet all critical requirements and special needs. Inventory is
maintainer to ensure rapid delivery.
FLAME ARRESTERS
Model 8100 A Series are designed to inbihit flame propagation in gas piping
systems and to protect low pressure tanks containing flammable liguids.
Arresters protect low flash point liguids from externally caused sources of heat
and ignition.This provides increased fire protection and safety.
SPECIAL FEATURES
Model 8100A Series are built of corrosion resistant materials throughout. Wafer
design construction affords easy accessibilty to the flame bank. Additionally, jack
screws aid in the removal from the shell assembly. All Aktek flame arrester flame
banks utilize spiral wound, crimped ribbon constructed flame elements. These
proven, Factory Mutual approved elements have been reported, by NTIS of the
Dept. of Commerce, to provide the best flame quenching performance
for the least pressure drop. Akteks special recessed flame bank seating
construction uniqueyly provides an extra measure of protection against leakage
and possible flame propagation.
TECHNICAL DATA
Sizes 2 through 60
Available in Carbon steel, Stainless steel aluminum(type
other materials
Water design for quick and easy maintenance.
Unique recessed seating for superios protection
Factory Mutual approval for most sizes and materials
Proven spiral wound, crimped ribbon, flame element
356)
and
Checked
O.A.
Approved
IIHSAN AKGUN
Checked
O.A.
MODEL 8100A
Rev
Page : 2/4
Approved
Job
1 0 1
Date : 16.04.2009
IIHSAN AKGUN
MODEL 8100A
SPECIFICATION
MODEL 8100A FLAMA ARRESTER
Rev
Job
Page : 3/4
1 0 1
Date : 16.04.2009
Dimensions, [mm]
Size Code
02
03
04
06
08
10
12
10
12
Max.
240
300
380
480
590
650
830
Max. Height
345
430
539
648
751
877
1050
Flange In Diameter
102
191
230
Flange Diameter
24
Hole Diameter
20
Number Of Holes
MATERIAL LIST
CONSTRUCTION
ITEM
1
2
3
4
5
6
7
8
9
10
OPTIONAL FEATURE
DESCRIPTION
BODY
BUSH
ARRESTER ELEMENT
BOLT
NUT
CUP NUT
INLET
STUD
WASHER
NUT
ALUMINUM
CARBON STL
316 SS
AL GR 356 T6
Teflon FED
SS
SS
SS
SS
CS
SS
SS
SS
CS WCB
Teflon FED
SS
SS
SS
SS
ALUMINUM
SS
SS
SS
CF-8M(316 SS)
Teflon FED
SS
SS
SS
SS
316 SS
SS
SS
SS
Checked
O.A.
Approved
IIHSAN AKGUN
MODEL 8100A
SPECIFICATION
MODEL 8100A FLAMA ARRESTER
Rev
Page : 4/4
Job
1 0 1
Date : 16.04.2009
Ordering Information
Model Description
8100D Flama arrester
Code
Configuration
1
2
VERTICAL
HORIZONTAL
Code
0B
1B
Model
FLANGED
All Weater Type
Code
2
3
4
6
8
0
1
Size
2
3
4
6
8
10
12
Code
1
2
3
Code
58
0B
(Example)
Noter :
Include Model Number When Ordering.
For special options, consult factory.
Checked
O.A.
Approved
IIHSAN AKGUN