Sunteți pe pagina 1din 2

www.fiberlogix.

com

Aerial Cable
Cables
Central Strength Member
PBT Loose Tube
Optical Fiber

Thixotropic Jelly
Flooding Jelly

Polyester Binding Yarn

Single Side Water Swellable Tape


Peripheral Strength Member
Identification Tape
HDPE Outer Sheath

FEATURES & APPLICATIONS


Application in LAN, WAN, Cable TV,
rural communication, power networks,
railway networks, mountainous terrain
Ultra high tensile strength

Harnessing

All dielectrical

The Power

Immune to lightning strikes

Of

Light

Superior moisture protection


Ultra light weight / flexible

Easy handling and installations

Harnessing The Power Of Light

w.w.w.fiberlogix.com

Aerial Cable
Characteristics
Construction Parameters and Material Types
Fiber count / number of tubes
Tube jelly type
Filler (if required)
Central element type
Core moisture protection
Core wrap
Peripheral strength member
Longitudinal moisture protection
Jelly under inner sheath
Outer sheath thickness, mm / Material
Approximate cable weight, kg / km
Cable delivery length, km
Optical Fiber Characteristics
Fiber type

6 to 96 / 3 to 8
PBT typeThixotropic jell
MDPE
GRP / FRP
Flooding jell
Yes
Aramid yarn
One side swellable tape
NA
2 / HDPE
139 to 225
2, 4 & 6

Cladding / Coating diameter, [m

125 1 / 2455

Clad non-circularity, %

W1

Mode Field diameter, [m

Core clad concentricity error, [m

AC

SM

8.8 to 9.8
W 0.80

Mode field concentricity error, [m

W1

Chromatic dispersion, ps/(nm . km)

W 3.5 at 1310, W 18 at 1550

Zero dispersion slope, ps/(nm . km)


Zero dispersion wavelength, mm

W 0.095
1300 to1322

Max. att single cabled fiber1310/1550dB/km

W 0.38 / 0.28

Cabled fiber cut-off, nm

W 1260

Average att of cable, dB/km


Mechanical and Environmental Characteristics
Tensile strength, Newton
Crush strength, Newton
Impact, points
Repeated bending, cycles
Torsion, cycles
Water penetration, hours
Minimum bending diameter, mm
Temperature cycling, cycles
O
Operating temperature, C
Ice layer on the cable
Wind load, km / hour
Bird load, Newton / meter
Cable sag, %
Distance between poles, meter
Cable elongation, %
Applicable standards

W 0.36 / 0.25

For 06 to 36 fiber 3200, for 48 to 96 3500


2000
5
100
5
24
Unloaded 10 x OD, Loaded 20 x OD
10
-15 to +75
4 mm, all around the cable
100
9
2
40
0.3
ITU-T G650, G652, G655, IEC-793-1 & 2,
IEC-794-1 & 2, TIA/EIA- 598A, EN 188 000
AC All Dielectric Self supporting Aerial, PBT Polybutylene Terephtalate, MDPE Medium Density
Polyethylene, GRP Glass Reinforced Plastic, WS Water Swellable, HDPE High Density Polyethylene, SM
Single Mode Fiber, OD Outer Diameter, att Attenuation, NA Not Applicable

Harnessing

The Power
Of

Light

Customized designs are available on request

For ordering information please visit www.fiberlogix.com

FiberLogix
Crown House, North Circular Road,
London, NW10 7PN. U.K.

Telephone - +44 (0) 20 8965 7000 Facsimile - +44 (0) 20 8965 7001
Website - www.fiberlogix.com Email - info@fiberlogix.com