Documente Academic
Documente Profesional
Documente Cultură
Smokeless Burner
SUMMI T
ENERGY EQUIPMENT
www.summitenergyequipment.com
SUMMI T
Flare Stack
Smokeless Burner Advantages
ENERGY EQUIPMENT
EPA Requirements
Flare Systems Meet All EPA Requirements
Summit open flare systems are guaranteed to meet EPA
requirements for 40 CFR 60.18 and have destruction
removal efficiency (DRE) of 98%. If higher destruction is
required, an enclosed flare system may be utilized if it is
economically practical.
Our designs are based on experience with flare
installations and flow medium analysis supplied by
customer. Summit is a leader in flare system innovation
and design, having supplied and installed successful,
proven systems nationwide. From our use of modern
structural and control techniques, to our proven
flare tip and seal designs, Summit is committed to
manufacturing the best flares built. We are able to
accomplish this goal in part due to the following:
Summit believes in safety first. Our flare system designs
adhere to the strictest of safety standards.
Flares are of the highest quality.
Flare Pilots are designed for years of reliable, continuous
operation.
Summit Flame Retention Rings promote stable
combustion and prevent lift-off at high exit velocities.
Summit Purge Seals are designed for maximum
efficiency and low operating cost.
Prompt and reliable pilot ignition/monitoring
systems allow for optimum performance of the flare
systems.
Our experience and relentless pursuit to keep our
customers happy are unmatched in the combustion
and flare industries.
SUMMI T
Flare Stack
Smokeless Tip Specifications
ENERGY EQUIPMENT
Tip Specifications
H2S FLARING
2. OTHER CONSIDERATIONS
Tip Velocity is calculated at less than 400 ft/sec
Ideal pressure on standard Summit burners is 30 PSI
except when higher BTU gas is being burned than
what the tip is designed for
Explanation: Heavier gasses (2,300 BTU/ft3 would
use lower pressure than what the tip is for if it is
designed for (1,400 BTU/ft3)
3. BURNER TIP CAPACITY FLOW RATE
0 - 1,000,000 MSCF/d
1,000,000 - 2,000,000 MSCF/d
2,000,000 - 4,000,000 MSCF/d
4,000,000 - 6,000,000 MSCF/d
Guarantee
Summit can guarantee that when the smokeless burners
are operated within their designed parameters, they will
burn smokeless.
Uses
SUMMI T
ENERGY EQUIPMENT
Flare Stack
Specifications
4 x 40
4 x 60
6 x 60
SUMMI T
ENERGY EQUIPMENT
Flare Stack
Pilot Igniter
Summits SP8 Series Spark Ignited Pilots are designed to provide an ignition source for small to medium size flares.
Ignition of the pilot gas is assured by an intermittent spark in the pilot nozzle every two seconds regardless of the
pilot flame temperature.
Control for the SP8 Series Pilots includes a Spark Oscillator Module, thermocouple controller (with alarm contacts
and an analog temperature retransmission signal), battery and battery charger in a Nema 4 fiberglass enclosure.
The standard controls for the SP8 Series Pilots are
designed to operate on 120 VAC and will provide 10
hours of operation during power disruption. Minimum
methane requirement for this pilot is 70scfh@ 5 psi. As
with all of our equipment, custom pilots and controls
are offered to meet field requirements.
Flare Stack
Warranty
SUMMI T
ENERGY EQUIPMENT
Warranty applies to fabrication, defective workmanship or materials, assembly and manufactured components.
Summit Energy Equipment warrants all fabrication and assembly for one (1) year from the date that each flare is
commissioned successfully. Warranty does not cover the removal, re-installation or modification of equipment.
All manufacturers warranties for third party components installed are passed on and these items are not
underwritten by Summit Energy Equipment. Any defective component must be returned to Summit for
replacement under warranty. Shipping costs and labor to replace the items are not covered by warranty.
Summit Energy Equipment guarantees and warrants that the environmental control equipment supplied will
effectively thermally oxidize the waste gas for the process conditions specified herein. Summit Energy Equipment
does not provided any performance guarantee if the operating conditions differ from the client specified design
conditions as detailed in this proposal or if the sizing and design of the equipment has been provided to Summit
by others. Summit Energy Equipment liability hereunder shall be limited to the obligation to repair or replace only
those products proven to have been defective in material or workmanship at the time of delivery. Warranty does not
cover the removal, re-installation or modification of equipment.
Summit Energy Equipment total cumulative liability in any way arising from or pertaining to any product sold
or required to be sold under this contract shall not in any case exceed the purchase price paid by Buyer for such
products. In no event shall Summit Energy Equipment have any liability for commercial loss, lost profits, claims
for labor, or consequential or incidental damages of any type, whether buyers claim be based in contract, tort,
warranty, strict liability, negligence, or otherwise. It is expressly agreed that buyers remedies expressed herein are
buyers sole and exclusive remedies.
The above stated warranty, which is given expressly in lieu of all other warranties, expressed or implied by the
customer, trade usage or law, including warranties of merchantability and fitness for particular purpose, constitutes
the only warranty made by the seller.
Contact
Request a Quote
SUMMI T
ENERGY EQUIPMENT