Instrument Cable Size 0.5


to 2.5
Power Cable Size 0.5 mm to 6.3 mm
Instrument Cable Pair 1 to 24 Pair
Instrument Gland Size Normally 16mm (1/2 to
8)
Instrument is Install at 1.5m or 4.5f above
Lug is used because to know the accurate Current
Instrument Cable check by (1) Multimetre (2)
Continuity Tester
Instrument Cable Type (1) Power Cable (2) Control
Cable(3)Signal Cable
M.C.C voltage 440V
Trunk Cable- from Field to Control Room
Power Cable Type (1) LT (Low Tension) 1000 V
(3.5 Core)
(2) HT (High Tension)
11000 V (3 Core)
(3) ST (Super Tension)
33000 V
(4) EST (Extra Super
Tension) 66000 V
mm

mm

Types of Condenser (1)Mica (2)Variable Air


(3)Electrolytic
Types of Megger (1)Up to 500Vfor Instrument
Cable (2)Up to 1000V for Power Cable

Merging of Instrument Cable (1)Armour to Lid


(2)Lid by Lid
Types of Earth (1)Main (2)Ground (3)Plating
(4)Tutor (5)Estator
Types of Fuse (1)Kitkat (2)Kartridge (3)HRC(used
in Instrument area because it is not damage)
Types of Lugs (1)Ring (2)pin (3)U (4)Flat
Types of Circuit (1)Open (2)Close (3)Short
Types of Junction Box (1)Flame Proof (2)Water
Proof (3)Chemical Proof
Types of Gland (1)Single compression(used in
Pannel) (2)Double compression(used in JB &
Instrument) (3)PVC(Poly Vinyl Chloride)
Types of Single compression
Gland(1)PVC(2)Copper
Types of Double compression Gland(1) ET (equal
thread) It has Check Nut & used in JB
(2)NPT(nonpolar thread) It has no Check nut &
used in Instrument
Types of Conduit (1)GI (2)PVC (3)MS (4)SS
Types of Wire in Cable (1)Single Stand (2)Multi
Stand
Types of Cable (1)Armour (2)Non Armour
RTD Cable Colour (1)Black(2)White(3)Red
T/C have two wire
Types of Flexible Cable (1)PVC (2)Metal

Types of Control Cable (1)Thermo (2)Thread


(3)Flexible
Inside Armour Cable (1)Insulation (2)Armer
(3)Insulation (4)Poly Paper (5)Silver Foil (6)Lid
(7)Single or Multi Stand
Inside Non Armour or Flexible Cable (1)Insulation
(2)Poly Paper (3)Silver Foil (4)lid (5)Single or
Multi Stand
Inside Power Cable (1)Insulation (2)Armer
(3)Insulation (3)Single or Multi Stand
Inside Panels (1)Voltmeter (2)Ammeter (3)Relay
(4)Transformer (5)Diode (6)Transistor (7)Thyristor
(8)IC (9) Capacitor (10) Resistor
Thermo Cable (1)It has 1 to 24 Pair (2)It has One
Stand (3)It is used in steam line or hot line
Thread Cable (1)It has three Wire (2)It is used only
in RTD
Flexible Cable (1)It has 1 to 24 Pair (2)It is used in
Instrument
Monkey Player- to tightened Gland
Wire Staper-to remove insulation
DOL starter is used in 5HP motor
Star Delta starter is used in 10HP motor
Auto Transformer starter is use in25 HP motor
Resistence Starter is use in 30 HP motor

VOLTAGE in
1 Phase 110 to 220V
2 Phases 380 to 440V
3 Phases 440 to 1000V
CABLE SIZE
1)1.5 2C
2)1.5 3C
3)1.5 4C
4)2.5 3C
5)2.5 4C
6)4
3C
7)6
3C
8)10 4C
9)16 3C
10)16 3C
11)25 4C
12)35 4C
13)50 4C
14)25*31/2C
15)35*31/2C
16)50*31/2C

1.5
2.5
4

GLAND SIZE
3/8

5/8
5/8

7/8
1
1*1/8
1*1/8
1*1/4
1*1/4
1*3/8
1*1/4
1*1/4
1*3/8

CABLE SIZE(mm2) CURRENT CAPACITY


5A
15A
28A

6
10
16
25
35
50
70
95
120
150
185
220
240
300

40A
50A
66A
86A
100A
120A
140A
175
195A
220A
240A
260A
270A
370A