Sunteți pe pagina 1din 42

No.

PDD No.

Parameter

EFCO2,Methane

CO2 emission factor for methane

49.55

Tx

Annual operating hours for plant/equipment x

8760

TDLj,y

Average technical transmission and distribution losses for


providing electricity to source j in year y
Gas consumption rate for transportation of 1 cubic meter
of gas by compressor 10GCNAM/25-55

PJ

Input capacity of NQK-7/1-5 compressor

VF,y

NCVRG,F,y

FCi,j,y

ECPJ,j,y

10

10

wC,i,j

11

11

i,y

12

12

FCn,i,t

13

13

EGn,t

14

14

EFCO2,i,t

15

15

NCVi,t

16
17
18
19

16

Nj
ERy
BEy
PEy

Description

Value

0
0.075
75

Volume of total recovered gas measured at point F in


Figure 2, after pre-processing and before the part of the
recovered gas may be used on-site, during the period y
162,315,748
Net calorific value of recovered gas measured at point F
in Figure 2 during the period y
0.00003692
Quantity of fuel type i combusted in process j during the
year y
12,173,681
Quantity of electricity consumed by the project electricity
23652
consumption source j in year y
Weighted average mass fraction of carbon in fuel type i in
year y (tC/mass unit of fuel)
0.6890572249
Weighted average density of fuel type i in year y
(tC/mass unit of fuel)
0.0006771156
Quantity of fossil fuel type i fired in the captive power
plant n in the time period t
44,552,027.02
Quantity of electricity generated in captive power plant n
in the time period t
88,166.00
Average CO2 emission factor of fossil fuel type i used in
the period t
0.0463396765
Average net calorific value of fossil fuel type i used in the
period t
0.03691786
Number of electricity consumption sources operational
36
during the period y
Emission reductions during the period y
276,095
Baseline emissions during the period y
296,921
Project emissions in the period y
20826.26784668

20

CO2 emissions due to consumption of fossil fuels during


PECO2,fossilfuels, y the period y

21
22
23

PECO2, elec, y
d
n

24

EFEL,j,y

25
26

COEFi,y

20826.26784668

CO2 emissions due to the use of electricity during the


period y
Operational days per year
Conversion factor for gas volume
Emission factor for electricity generation for source j in
year y

0.86448

CO2 emission coefficient of fuel type i in year y


Average annual decrease in LP APG production

0.001711
-4.6%

365
0.932

Unit
tCO2/TJ
hours

Reference

Comment

Default value AM0009 ver. 04

n/a

Conservative assumption (full load operating hours)

n/a

kW

According to the tool


Calculated based on data indicated in technical specification
of the compressor
n/a
Indicated on the tag at the compressor onsite and in
technical specification
n/a

Nm

Measured by gas flow meters at the monitoring point F

m3

Measured at the monitoring point F

Estimated for determination of EX ANTE


baseline emissions
Estimated for determination of EX ANTE
baseline emissions

Measured by project participants: ratio of the recovered gas

Value here determined for 2010

Mesured by project participants

Value here determined for 2010

Calculated based on the results of gas chromatography

Determined for the gas samples available

Calculated based on the results of gas chromatography


Measured by gas flow meters installed at the gas-turbine
power plant
Measured by electricity meters installed at the gas-turbine
power plant

Determined for the gas samples available

tCO2/GJ

Calculated

GJ/Nm3

Measured at tthe entry in power plant

n/a
Estimated for determination of EX ANTE
baseline emissions

TJ/Nm3
m3
MWh/yr
tC/t
t/Nm3
Nm3
MWh

tCO2e
tCO2e
tCO2e

Number of compressors NQK-7/1-5 in operation


Calculated according to AM0009 ver.04
Calculated according to AM0009 ver.04
Calculated according to AM0009 ver.04

tCO2e

Calculated according to the Tool to calculate project or


leakage CO2 emissions from fossil fuel combustion, ver. 02

tCO2e
days
Nm3/Sm3

Calculated according to the Tool to calculate baseline,


project and/or leakage emissions from electricity
consumption, Ver. 01
n/a
Calculated: 0/20 C = 273.16/293.16 K

tCO2/MWh

Calculated

tCO2/m3
%

Calculated according to the Tool to calculate project or


leakage CO2 emissions from fossil fuel combustion, ver. 02
Assumption by SOCAR

Average of the last 3 years


Average of the last 3 years

n/a
n/a

n/a
n/a

Table: Estimated emission reductions


Year
2008
2009
2010
2011*
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
Total 2013-2022
Annual average 2013-2022

Estimated baseline
emissions, tCO2
43,347
166,840
296,921
86,373
329,598
314,437
299,973
286,174
273,010
260,452
248,471
237,041
226,137
215,735
205,811
2,567,241
256,724

Estimated project
emissions, tCO2
5,560
21,362
35,946
11,098
43,278
42,214
41,200
40,232
39,309
38,428
37,587
36,786
36,021
35,291
34,595
381,664
38,166

Estimated leakage,
tCO2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

Estimated emission
reductions, tCO2
37,787
145,478
260,975
75,275
286,321
272,223
258,773
245,942
233,701
222,024
210,883
200,255
190,116
180,444
171,216
2,185,577
218,558

Check
314,437
299,973
286,174
273,010
260,452
248,471
237,041
226,137
215,735
205,811

Determination of baseline emissions


Table 1: Project sites and APG recovery
No

Oil field

Project site

NCV, TJ/Nm3

Start of operations,
month/year

1
2
3
4
5
6
7
8

N. Dashlari
N. Dashlari
N. Dashlari
N. Dashlari
Palchiq P.
Palchiq P.
N. Dashlari
N. Dashlari
TOTAL

2192
1517
741
2346
1005a
1201
1799
810

0.00003692
0.00003692
0.00003692
0.00003692
0.00003692
0.00003692
0.00003692
0.00003692

3rd 2008
3rd 2008
1st 2009
2st 2009
1st 2010
4th 2011
1st 2010
1st 2010

2008
9,617,312
14,078,847
0
0
0
0
0
0
23,696,159

Table 2: Oil and gas production at project sites

No

Oil field

Project site

Total low pressure


APG volume,
Sm3/year at 20C

Total low pressure


APG volume,
Nm3/year at 0C

1
2
3
4
5
6
7
8

N. Dashlari
N. Dashlari
N. Dashlari
N. Dashlari
Palchiq P.
Palchiq P.
N. Dashlari
N. Dashlari
Total

2192
1517
741
2346
1005a
1201
1799
810

20,638,008
30,212,119
21,422,780
34,115,958
13,793,024
36,500,000
18,997,050
39,873,477
215,552,416

19,234,623
28,157,695
19,966,031
31,796,073
12,855,098
34,018,000
17,705,251
37,162,081
200,894,852

2008
17,593
25,754
0
0
0
0
0
0
43,347

2009
35,186
51,508
36,523
43,623
0
0
0
0
166,840

Table 3: Baseline emissions


No
1
2
3
4
5
6
7
8

Project site
2192
1517
741
2346a
1005A
1201
1799
810
TOTAL

Start of
operations,
quarter/year
3rd 2008
3rd 2008
1st 2009
2st 2009
1st 2010
4th 2011
1st 2010
1st 2010

Table B.6.3.1.: Baseline emissions

Period

Volume of
recovered gas, Nm3

Baseline
emissions, tCO2

VF,y

Net
calorific
value,
3
NCV
RG,F,y
TJ/Sm

y
2008

23,696,159

0.000036918

43,347

BEy

2010
33,567
49,139
34,843
55,488
23,516
0
32,388
67,980
296,921

2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
Total
20132022

91,205,404
162,315,748
47,216,806
180,179,332
171,891,082
163,984,093
156,440,824
149,244,546
142,379,297
135,829,850
129,581,676
123,620,919
117,934,357
112,509,377

0.000036918
0.000036918
0.000036918
0.000036918
0.000036918
0.000036918
0.000036918
0.000036918
0.000036918
0.000036918
0.000036918
0.000036918
0.000036918
0.000036918

166,840
296,921
86,373
329,598
314,437
299,973
286,174
273,010
260,452
248,471
237,041
226,137
215,735
205,811

1,403,416,022

2,567,241

Low pressure APG quantity, Nm3/year


2009

2010

2011

2012

2013

2014

19,234,623
28,157,695
19,966,031
23,847,055
0
0
0
0
91,205,404

18,349,831
26,862,441
19,047,594
30,333,454
12,855,098
0
17,705,251
37,162,081
162,315,748

4,376,435
6,406,692
4,542,851
7,234,529
3,065,941
8,504,500
4,222,702
8,863,156
47,216,806

16,700,475
24,447,937
17,335,520
27,606,961
11,699,631
32,453,172
16,113,832
33,821,804
180,179,332

15,932,253
23,323,332
16,538,086
26,337,041
11,161,448
30,960,326
15,372,596
32,266,001
171,891,082

15,199,369
22,250,459
15,777,334
25,125,537
10,648,021
29,536,151
14,665,456
30,781,765
163,984,093

Factor
0.25
0.50
0.75
1

Quarter
4
3
2
1

2015
26,525
38,830
27,534
43,847
18,582
51,545
25,593
53,718
286,174

2016
25,305
37,044
26,267
41,830
17,727
49,173
24,416
51,247
273,010

Baseline emissions, tCO2/y


2011
8,006
11,720
8,310
13,234
5,608
15,557
7,725
16,213
86,373

2012
30,550
44,722
31,712
50,501
21,402
59,366
29,477
61,870
329,598

2013
29,145
42,665
30,253
48,178
20,417
56,635
28,121
59,024
314,437

2014
27,804
40,702
28,861
45,962
19,478
54,030
26,827
56,308
299,973

m3/year
2015

2016

2017

2018

2019

2020

2021

14,500,198
21,226,938
15,051,576
23,969,763
10,158,212
28,177,488
13,990,845
29,365,804
156,440,824

13,833,189
20,250,499
14,359,204
22,867,153
9,690,934
26,881,324
13,347,266
28,014,977
149,244,546

13,196,862
19,318,976
13,698,681
21,815,264
9,245,151
25,644,783
12,733,292
26,726,288
142,379,297

12,589,807
18,430,303
13,068,541
20,811,762
8,819,874
24,465,123
12,147,561
25,496,879
135,829,850

12,010,676
17,582,509
12,467,388
19,854,421
8,414,160
23,339,727
11,588,773
24,324,022
129,581,676

11,458,184
16,773,713
11,893,888
18,941,118
8,027,109
22,266,100
11,055,689
23,205,117
123,620,919

10,931,108
16,002,123
11,346,770
18,069,826
7,657,862
21,241,859
10,547,128
22,137,682
117,934,357

Total
2017
24,141
35,340
25,059
39,906
16,912
46,911
23,293
48,890
260,452

2018
23,030
33,714
23,906
38,071
16,134
44,754
22,221
46,641
248,471

2019
21,971
32,163
22,806
36,319
15,392
42,695
21,199
44,495
237,041

2020
20,960
30,684
21,757
34,649
14,684
40,731
20,224
42,449
226,137

2021
19,996
29,272
20,756
33,055
14,008
38,857
19,294
40,496
215,735

2022
19,076
27,926
19,802
31,534
13,364
37,070
18,406
38,633
205,811

2013-2022

268,502
393,063
278,712
443,852
188,101
521,767
259,071
543,771
2,777,401

2022
10,428,277
15,266,025
10,824,818
17,238,614
7,305,600
20,264,734
10,061,960
21,119,349
112,509,377

TOTAL 2013-2022
130,079,923
190,424,876
135,026,286
215,030,501
91,128,372
252,777,614
125,510,566
263,437,884
1,403,416,022

Determination of project emissions


Table B.6.3.3. Electricity consumption source J
No
Unit
1
2
3
4
5
6
7
8

Project site

Number of NQK units


installed

Input capacity per unit


PJ

Units in
operation

number
5
8
5
9
2
10
6
4
49.00

kW/unit
75
75
75
75
75
75
75
75

number
3
6
3
7
2
9
2
4
36.00

2192
1517
741
2346
1005A
1201
1799
810
TOTAL

Table 2: Electricity consumption for compression of high pressure APG


No
1
2
3
4
5
6
7
8

Start of operations,
qarter/year
3rd 2008
3rd 2008
1st 2009
2st 2009
1st 2010
4th 2011
1st 2010
1st 2010

Project site

2192
1517
741
2346a
1005A
1201
1799
810
Total electricity consumption, MWh/y

2008
986
1,971
0
0
0
0
0
0

2009
1,971
3,942
1,971
3,449
0
0
0
0

2,957

11,333

2008
2,520

2009
9,660

3,040
5,560

11,702
21,362

Input capacity
per unit
kW
450
225
225
300
375

Table 3: Project emissions by sources


No
1
2

Project emissions by sources


CO2 emissions due to electricity consumption
CO2 emissions due to fossil fuels consumption
TOTAL Project Emissions
Source: 20090528 Energieverbrauch_ru.doc

No

Equipment type

Project site

Number of units installed

Electric engine of
compressor

2164
2182
2192
1517
741

number
6
3
3
4
5
21

Unit

TOTAL

Letter signed by
No

Project site

Unit
1

2192

1517

741

2346

5
6

1005A
1201

1799

810
TOTAL

Number of NQK units


installed
number
3
1
1
4
1
2
1
5
6
3
2
10
3
2
1
3
1

Date of commissioning
15.07.2008
18.08.2009
29.11.2009
01.09.2008
15.08.2009
22.12.2009
18.07.2010
16.02.2009
27.04.2009
01.09.2009
06.12.2009
2011
23.03.2010
28.03.2010
28.07.2010
02.10.2009
13.10.2009

Total NQK
installed
5

8
5
9
2
10
6
4
49

Input capacity in total

Consumption of
Operational
electricity per year, Start of operations
hours per year
ECPJ,j,y

Factor
0.25

kW
225
450
225
525
150
675
150
300

hours
8760
8760
8760
8760
8760
8760
8760
8760

MWh/y
1,971.00
3,942.00
1,971.00
4,599.00
1,314.00
5,913.00
1,314.00
2,628.00
23,652.00

Quarter/year
3rd 2008
3rd 2008
1st 2009
2st 2009
1st 2010
4th 2011
1st 2010
1st 2010

2010
1,971
3,942
1,971
4,599
1,314
0
1,314
2,628

2011
493
986
493
1,150
329
1,478
329
657

2012
1971
3942
1971
4599
1314
5,913
1314
2628

2013
1971
3942
1971
4599
1314
5,913
1314
2628

Years
2014
1971
3942
1971
4599
1314
5,913
1314
2628

2015
1971
3942
1971
4599
1314
5,913
1314
2628

17,739

5,913

23,652

23,652

23,652

23,652

2010
15,120

2011
5,040

2012
20,160

2013
20,160

20,826
35,946

6,058
11,098

23,118
43,278

22,055
42,214

Units in operation

Total input
capacity
kW
1800
450
450
1200
1125

number
4
2
2
4
3
15

Operational hours per Consumption of


year
electricity per year
hours
MWh/y
1440
2592
2880
1296
2880
1296
2160
2592
1728
1944
9720

0.50
0.75
1

Project emissions, tCO2/y


2014
2015
20,160
20,160
21,040
41,200

20,072
40,232

Quarter
4
3
2
1

2016
1971
3942
1971
4599
1314
5,913
1314
2628

2017
1971
3942
1971
4599
1314
5,913
1314
2628

2018
1971
3942
1971
4599
1314
5,913
1314
2628

2019
1971
3942
1971
4599
1314
5,913
1314
2628

2020
1971
3942
1971
4599
1314
5,913
1314
2628

2021
1971
3942
1971
4599
1314
5,913
1314
2628

2022
1971
3942
1971
4599
1314
5,913
1314
2628

23,652

23,652

23,652

23,652

23,652

23,652

23,652

2016
20,160

2017
20,160

2018
20,160

2019
20,160

2020
20,160

2021
20,160

2022
20,160

19,149
39,309

18,268
38,428

17,428
37,587

16,626
36,786

15,861
36,021

15,132
35,291

14,436
34,595

2/y

Total
2013-2022
19,710
39,420
19,710
45,990
13,140
59,130
13,140
26,280
236,520
236,520

Total
2013-2022
201,595
180,068
381,664
381,664

Project site
No.

Collector platforms (with


compressors)

2192

1517

741A

2346

1005A

1201

1799

810
8 collector platforms

Supplier platforms
2192
679
2223
1620
M-1
1501
1923
201
348
1757
1745
1741
1767
1926
1517
259
258
741
501
1544
2346
1624
915
416a
1304
1005
1063
1183
1100
1077
1126
1127
1157
1201
1145
1146
1799
606
1773
1594
419a
516a
1956
1955
1954
1645
617
810
1887
2112
50 supplier platforms

Project implementation
schedule: completion date
15.07.2008
15.07.2008
15.07.2008
15.07.2008
01.09.2008
01.09.2008
01.09.2008
01.09.2008
01.09.2008
01.09.2008
01.09.2008
01.09.2008
01.09.2008
01.09.2008
01.09.2008
01.09.2008
01.09.2008
Dec-08
Dec-08
Dec-08
Apr-09
Apr-09
Apr-09
2009
2009
2009
4th quarter 2011
4th quarter 2011
4th quarter 2011
4th quarter 2011
4th quarter 2011
4th quarter 2011
4th quarter 2011
4th quarter 2011
4th quarter 2011
4th quarter 2011
2009/2010
2009/2010
2009/2010
2009/2010
2009/2010
2009/2010
2009/2010
2009/2010
2009/2010
2009/2010
2009/2010
2010
2010
2010

Data provided by the Gas Quality Certificate


Conditions
Standard
Temperature and pressure
20C & 101.325 kPa
Density, kg/m3
Net calorific value, kcal/m3
8,205
Net calorific value, MJ/m3
34.35
Wobbe index, kcal/m3
9,977

Working
25.1C & 101.325 kPa
0.815
9,081
38.02
11,041

Normal
0C & 101.325 kPa
0.677
8,818
36.92
10,716

Re-calculation of results: Gas Quality Certificate


Gas component
methane
ethane
propane
isobutane
butane
isopentane
pentane
hexan+higher hydrocarbon
nitrogen
carbon dioxide
hydrogen suphide
oxygen
Total
Conversion factor: Cal to J
Conversion factor: MWh to GJ

Chemical formula
CH4
C2H6
C3H8
iC4H10
nC4H10
iC5H12
nC5H12
C8+ (C6H14)
N2
CO2
H2S
O2
J/Cal
GJ/MWh

Norma
Gas composition,
volume %
87.01
3.55
1.43
0.87
0.00
0.47
0.00
0.16
0.00
6.51
0.0000
0.0000
100.00
4.1868
3.6

NCV of gas component


kcal/Nm3
8,570
15,370
22,260
29,320
29,510
37,410
37,410
41,360
0
0
5,580
0

Re-calculation of results: Gas Quality Certificate No. 83 by SOCAR's Laboratody dated 23.09.2009 (Sample ND-2)
at 0C & 101.325 kPa
Gas component
Chemical formula
NCV, MJ/m3
NCV, kcal/m3
methane
CH4
35.88
8,570
ethane
C2H6
64.36
15,370
propane
C3H8
93.18
22,260
butane
nC4H10
123.57
29,510
isobutane
iC4H10
122.78
29,320
pentane
nC5H12
156.63
37,410
hexan
C6H14
173.17
41,360
heptane
C7H16
200.55
47,900
oktane
C8H18
227.76
54,400
nonane
C9H20
250.23
61,200
benzole
C6H6
155.67
37,180
toluole
C7H8
168.18
40,170
hydrogen
H2
10.79
2,580
carbon monoxide
CO
12.64
3,020
hydrogen suphide
H2S
23.37
5,580
carbon dioxide
CO2
0.00
0
nytrogene
N2
0.00
0
oxygen
O2
0.00
0

helium
Total
Conditions
Wobbe Index, MJ/m3
Density, kg/m3
Net calorific value, kcal/m3
Net calorific value, MJ/m3

He

0.00

Normal
45.35
0.6490
8726.75
36.54

Standard
42.24
0.6482
8122.13
34.00

Cert.Data (Stand.)
42.85
0.6485
10234.05
34.59

Re-calculation of results: Gas Quality Certificate No. 83 by SOCAR's Laboratody dated 23.09.2009 (Sample ND-2a)
at 0C & 101.325 kPa
Gas component
Chemical formula
NCV, MJ/m3
NCV, kcal/m3
methane
CH4
35.88
8,570
ethane
C2H6
64.36
15,370
propane
C3H8
93.18
22,260
butane
nC4H10
123.57
29,510
isobutane
iC4H10
122.78
29,320
pentane
nC5H12
156.63
37,410
hexan
C6H14
173.17
41,360
heptane
C7H16
200.55
47,900
oktane
C8H18
227.76
54,400
nonane
C9H20
250.23
61,200
benzole
C6H6
155.67
37,180
toluole
C7H8
168.18
40,170
hydrogen
H2
10.79
2,580
carbon monoxide
CO
12.64
3,020
hydrogen suphide
H2S
23.37
5,580
carbon dioxide
CO2
0.00
0
nytrogene
N2
0.00
0
oxygen
O2
0.00
0
helium
He
0.00
0
Total
Conditions
Normal
Standard
Cert.Data (Stand.)
Wobbe Index, MJ/m3
46.90
43.67
44.33
Density, kg/m3
0.6129
0.6124
0.6125
Net calorific value, kcal/m3
8769.18
8162.83
10587.53
Net calorific value, MJ/m3
36.71
34.17
34.78

GOST 22667-82
Combustible natural
gases. Calculation method for determination of calorific value, specific gravity (index) and Wobbe index
Table Source: ANNEX of the GOST, Tables 1-2
Gas component

Chemical formula

at 0C & 101.325 kPa


NCV, MJ/m3

NCV, kcal/m3

methane

CH4

35.88

8,570

ethane

C2H6

64.36

15,370

propane
butane
isobutane
pentane

C3H8
nC4H10
iC4H10
nC5H12

93.18
123.57
122.78
156.63

22,260
29,510
29,320
37,410

hexan

C6H14

173.17

41,360

heptane

C7H16

200.55

47,900

oktane
nonane
benzole
toluole
hydrogen

C8H18
C9H20
C6H6
C7H8
H2

227.76
250.23
155.67
168.18
10.79

54,400
61,200
37,180
40,170
2,580

carbon monoxide

CO

12.64

3,020

hydrogen suphide

H2S

23.37

5,580

carbon dioxide

CO2

0.00

nytrogene
oxygen
helium

N2
O2
He

0.00
0.00
0.00

0
0
0

St.Petersburg Methodology - Methodology of calculation of emissions of hazardous substances into the atmosphere due to the flaring of
Petersburg Scientific Research Institute (SPI) for the Air Protection of the Ministry of Natural Resources of the Russian Federation. This methodology
Environmental Protection and Hydrometeorology (# 199 of 08.04.1998) and adopted from 01.01.1998 as the appropriate basis for reporting hazardo

Guidelines for calculation of net calorific values of APG

Parameter
Net Calorific Value of APG
Content of the component i in APG
Gas component
Net Calorific Value of APG compone

Unit
kCal/m3
%
n/a
kCal/m3

Net calorific value of gas components

Indication
QH
Vi
i
QHi

Normal conditions

NCV of gas component


MJ/Nm3
35.88
64.36
93.18
122.78
123.57
156.63
156.63
173.17
0.00
0.00
23.37
0.00

2009 (Sample ND-2)


1.325 kPa
Density
0.5548
1.0480
1.5540
2.0900
2.0810
2.6710
2.9760
3.4600
3.9450
4.4100
2.9670
3.1800
0.0695
0.9671
1.1880
1.5290
0.9670
1.1050

NCV
kcal/Nm3
7,457
546
318
255
0
176
0
66
0
0
0
0
8,818

MJ/Nm3
31.22
2.28
1.33
1.07
0.00
0.74
0.00
0.28
0.00
0.00
0.00
0.00
36.92

at 20C & 101.325 kPa


NCV, MJ/m3
NCV, kcal/m3
33.41
7,980
59.85
14,300
86.53
20,670
114.27
27,290
113.81
27,180
144.02
34,400
161.36
38,540
186.87
44,630
212.22
50,690
238.76
57,030
145.05
34,640
156.71
37,430
10.05
2,400
11.78
2,810
21.75
5,200
0.00
0
0.00
0
0.00
0

Standard conditions
Density of
component
kg/Nm3
0.5548
1.0480
1.5540
2.0810
2.0900
2.6710
2.6710
2.9760
0.9670
1.5290
1.1880
1.1050

Density
0.5546
1.0460
1.5490
2.0710
2.0680
2.6370
2.9760
3.4600
3.9450
4.4100
2.9670
3.1800
0.6950
0.9671
1.1880
1.5228
0.9670
1.1050

Gas Density

NCV of gas component

kg/Nm3
0.483
0.037
0.022
0.018
0.000
0.013
0.000
0.005
0.000
0.100
0.000
0.000
0.677

kcal/Sm3
7,980
14,300
20,670
27,180
27,290
34,400
34,400
38,540
0
0
5,200
0

Gas composition,
volume %
89.81
2.79
1.09
0.40
0.31
0.40
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
5.11
0.10
0.00

Qi
MJ/Nm3
32.22
1.80
1.02
0.49
0.38
0.63
0
0
0
0
0
0
0
0
0
0
0
0

0.1380

2009 (Sample ND-2a)


1.325 kPa
Density
0.5548
1.0480
1.5540
2.0900
2.0810
2.6710
2.9760
3.4600
3.9450
4.4100
2.9670
3.1800
0.0695
0.9671
1.1880
1.5290
0.9670
1.1050
0.1380

0.00

NCV, MJ/m3
33.41
59.85
86.53
114.27
113.81
144.02
161.36
186.87
212.22
238.76
145.05
156.71
10.05
11.78
21.75
0.00
0.00
0.00
0.00

at 20C & 101.325 kPa


NCV, kcal/m3
7,980
14,300
20,670
27,290
27,180
34,400
38,540
44,630
50,690
57,030
34,640
37,430
2,400
2,810
5,200
0
0
0
0

0.1380

Density
0.5546
1.0460
1.5490
2.0710
2.0680
2.6370
2.9760
3.4600
3.9450
4.4100
2.9670
3.1800
0.6950
0.9671
1.1880
1.5228
0.9670
1.1050
0.1380

0.00
100.01

0
36.54

Gas composition,
volume %
91.85
3.12
1.29
0.00
0.00
0.35
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
1.48
1.92
0.00
0.00
100.01

Qi
MJ/Nm3
32.96
2.01
1.20
0.00
0.00
0.55
0
0
0
0
0
0
0
0
0
0
0
0
0
36.71

Combustible natural
obbe index

1.325 kPa

Formula for calculation of

at 20C & 101.325 kPa


Density

NCV, MJ/m3

NCV, kcal/m3

Density

0.5548

33.41

7,980

0.5546

1.0480

59.85

14,300

1.0460

1.5540
2.0900
2.0810
2.6710

86.53
114.27
113.81
144.02

20,670
27,290
27,180
34,400

1.5490
2.0710
2.0680
2.6370

2.9760

161.36

38,540

2.9760

Formula for calculation of

3.4600

186.87

44,630

3.4600

3.9450
4.4100
2.9670
3.1800
0.0695

212.22
238.76
145.05
156.71
10.05

50,690
57,030
34,640
37,430
2,400

3.9450
4.4100
2.9670
3.1800
0.6950

0.9671

11.78

2,810

0.9671

1.1880

21.75

5,200

1.1880

1.5290

0.00

1.5228

0.9670
1.1050
0.1380

0.00
0.00
0.00

0
0
0

0.9670
1.1050
0.1380

Formula for calculation of

nces into the atmosphere due to the flaring of the associated petroleum gas at flaring stacks developed by the Saint
ces of the Russian Federation. This methodology has been approved and endorsed by the Decree of the State Committee for
98 as the appropriate basis for reporting hazardous emissions from flaring of APG.

Net calorific value of gas components


Component
CH4
C2H6
C3H8
iC4H10
nC4H10
iC5H12
nC5H12
C8+ (C6H14)
nC7H16
H2S

QHi, kCal/m3
8,555
15,226
21,795
28,338
28,338
34,890
34,890
44,700
51,300
5,585

Standard conditions
NCV of gas component

NCV

MJ/Sm3
33.41
59.85
86.53
113.81
114.27
144.02
144.02
161.36
0.00
0.00
21.75
0.00

kcal/Sm3
6,943
508
296
236
0
162
0
62
0
0
0
0
8,206

MJ/Sm3
29.07
2.12
1.24
0.99
0.00
0.68
0.00
0.26
0.00
0.00
0.00
0.00
34.36

Qi
kcal/Nm3
7696.72
428.82
242.63
118.04
90.89
149.64
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

di
kg/Nm3
0.4983
0.0292
0.0169
0.0084
0.0065
0.0107
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0781
0.0010
0.0000

Qi
MJ/Sm3
30.01
1.67
0.94
0.46
0.35
0.58
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

Qi
kcal/Sm3
7166.84
398.97
225.30
109.16
84.26
137.60
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

di
kg/Sm3
0.4981
0.0292
0.0169
0.0083
0.0064
0.0105
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0778
0.0010
0.0000

0.00
8726.75

0.0000
0.6490

0.00
34.00

0.00
8122.13

0.0000
0.6482

Qi
kcal/Nm3
7871.55
479.54
287.15
0.00
0.00
130.94
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
8769.18

di
kg/Nm3
0.5096
0.0327
0.0200
0.0000
0.0000
0.0093
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0226
0.0186
0.0000
0.0000
0.6129

Qi
MJ/Sm3
30.69
1.87
1.12
0.00
0.00
0.50
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
34.17

Qi
kcal/Sm3
7329.63
446.16
266.64
0.00
0.00
120.40
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
8162.83

di
kg/Sm3
0.5094
0.0326
0.0200
0.0000
0.0000
0.0092
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0225
0.0186
0.0000
0.0000
0.6124

mula for calculation of NCV

Q
Qi
i
Ci

Net Calorific Value of gas (kcal/m3 or MJ/m3)


Net Calorific Value (NCV) of gas component (kcal/m3 or MJ/m3)
Gas component
Share of gas component (%)

mula for calculation of Wobbe Index

Wobbe Index (kcal/m3 or MJ/m3)

Q
d

Net Calorific Value of gas (kcal/m3 or MJ/m3)


Density of gas (relative)

mula for calculation of Gas Density

d
i
Ci
di

Density of gas (relative)


Gas component
Share of gas component (%)
Relative density of gas component

Methodological tool
Tool to calculate baseline, project and/or leakage emissions from electricity consumption, Ver. 01
Scenario B: Electricity consumption from off-grid fossil fuel fired power plant
Parameter
PEEC,y

Description
Project emissions from electricity consumption in
year y

ECPJ,j,y

Quantity of electricity consumed by the project


electricity consumption source j in year y

TDLj,y

Average technical transmission and distribution


losses for providing electricity to source j in year y

Value

Unit

2,519.94 tCO2/yr

2,956.50 MWh/yr
0

FCn,i,y

Emission factor for electricity generation for source


j in year y
Quantity of fossil fuel type i fired in the captive
power plant n in the time period y

NCVi,y

Average net calorific value of fossil fuel type i used


in the period y

EFCO2,i,y

Average CO2 emission factor of fossil fuel type i


used in the period y

0.0463396765 tCO2/GJ

EGn,y

Quantity of electricity generated in captive power


plant n in the time period y

89,422.00 MWh

EFEL,j,y

0.8523 tCO2/MWh
44,552,027.02 Nm3
0.036917861 GJ/Nm3

Calculation of project emissions due to consumption of electricity


Years
2008
CO2 Emissions from electricity consumption (PE EC,j,y). tCO2/y
2,520
Quantity of electricity consumed in year y, MWh/y
2,957

2009
9,660
11,333

Methodological tool
Tool to calculate project or leakage CO2 emissions from fossil fuel combustion
(Version 02)
Parameter

Description

Value

PEFC,j,y

Are the CO2 emissions from fossil fuel combustion


in process j during the year y

FCi,j,y

Is the quantity of fuel type i combusted in process j


during the year y

COEFi,y

CO2 emission coefficient of fuel type i in year y

wC,i,j

Weighted average mass fraction of carbon in fuel


type i in year y

0.689 tC/t

p i,y

Weighted average density of fuel type i in year y

0.000677 t/Nm3

Calculation of project emissions from fossil fuel combustion


Years

Unit

3,040.39 tCO2/yr

1,777,211.94 Nm3
0.00171 tCO2/Nm3

2008

2009

CO2 Emissions from fossil fuel combustion (PEfc,j,y). tCO2/y


CO2 emission coefficient of fuel type i in year y, tCO2/m3
Quantity of associated gas combusted (FCi,j,y), 1000m3

Gas component

Gas composition

3,040
0.001711

11,702
0.001711

1,777.21

6,840.41

Chemical formula Molecular weight

Volume %

methane
ethane
propane
isobutane
butane
isopentane
pentane
hexan+higher hydrocarb
nitrogen
carbon dioxide
hydrogen suphide
oxygen
Total

87.01
3.55
1.43
0.87
0.00
0.47
0.00
0.16
0.00
6.51
0.00
0.00
100.00

CH4
C2H6
C3H8
iC4H10
nC4H10
iC5H12
nC5H12
C8+ (C6H14)
N2
CO2
H2S
O2

16
30
44
58
58
72
72
86
28
44
34
32

Table B.6.3.2. CO2 emissions due to fossil fuel consumption 2010-2012


Period

Quantity of associated gas combusted,


1000Nm3

CO2 emission
coefficient of
fuel type i in
year y,
tCO2/Nm3

CO2
Emissions
from fossil
fuel
combustion,
tCO2/y

y
2008
2009
2010
2011*
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022

FCi,j,y
1,777.21
6,840.41
12,173.68
3,541.26
13,513.45
12,891.83
12,298.81
11,733.06
11,193.34
10,678.45
10,187.24
9,718.63
9,271.57
8,845.08
8,438.20

COEFi,y
0.00171
0.00171
0.00171
0.00171
0.00171
0.00171
0.00171
0.00171
0.00171
0.00171
0.00171
0.00171
0.00171
0.00171
0.00171

PEfc,j,y
3,040
11,702
20,826
6,058
23,118
22,055
21,040
20,072
19,149
18,268
17,428
16,626
15,861
15,132
14,436

Total 2013-2022

105,256.20

180,068

consumption, Ver. 01
Formulae for Option B1:
Comment/Source
Calculated

PEEC,y = ECPJ,j,y * EF EL,j,y * (1+ TDL)

Determined by project
participants (here for year
2008)

EFEL, y = ( FCn,i,t * NCVi,t * EF CO2,i,t ) / EG n,t


EFCO2,i,t = COEF i,y / NCV i,t

According to the Tool


Calculated

Data on power plant consumption and production by Azneft

Gas flow meters

2005

2006

Measured and calculated by


project participants

Electricity generated
annually, MWh

0.00

83,292.00

Calculated by project
participants

Heat generated annually,


Gcal

0.00

10,000.00

0.00

44,752,000.00

0.00

41,698,923.18

2013
20,160
23,652

2014
20,160
23,652

Fuel gas consumed


annually, Sm3
Fuel gas consumed
annually, Nm3

Electricity meters

2010
15,120
17,739

2011
5,040
5,913

2012
20,160
23,652

3rd quarter of 2011 taken as the start of crediting period

Comment/Source

Formulae used for calculations:

Calculated

PEFC,y = FCi,j,y * COEF i,y

Calculated based on
technical specification of
compressors 10GCNAM/2555 for year 2008

COEFi,y = wC,i,y * i,y * 44/12

Calculated according to the


tool

Cross-Check: COEFi,y = NCVi,y * EF CO2,i,y

Measured in the laboratory


Measured in the laboratory

2010

2011

2012

2013

2014

20,826
0.001711
12,173.68

6,058
0.001711

23,118
0.001711

22,055
0.001711

21,040
0.001711

3,541.26

13,513.45

12,891.83

12,298.81

3rd quarter of 2011 taken as the start of crediting period

wC,i,j

i,y

FCi,j,y

Carbon content of component

Density of gas
component

Volume of component

Mass of component

Carbon content of gas

tC/t
0.750
0.800
0.818
0.828
0.828
0.833
0.833
0.837
0.000
0.273
0.000
0.000
0.689

kg/Nm3
0.555
1.048
1.554
2.081
2.090
2.671
2.671
2.976
0.967
1.529
1.188
1.105
0.677

1000*Nm3
1546.35
63.09
25.41
15.46
0.00
8.35
0.00
2.84
0.00
115.70
0.00
0.00
1777.21

tonnes
857.92
66.12
39.49
32.18
0.00
22.31
0.00
8.46
0.00
176.90
0.00
0.00
1203.38

kgC/Nm3
0.362
0.030
0.018
0.015
0.000
0.010
0.000
0.004
0.000
0.027
0.000
0.000
0.467

Table B.6.3.4. CO2 emissions due to electricity consumption 2010-2012


Period

Quantity of electricity
consumed by the
project, MWh/y

CO2 emission
factor for
electricity
generation,
tCO2/MWh

CO2 emissions from


electricity
consumption,
tCO2/y

y
2008
2009
2010
2011*
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022

ECPJ,j,y
2,956.50
11,333.25
17,739.00
5,913.00
23,652.00
23,652.00
23,652.00
23,652.00
23,652.00
23,652.00
23,652.00
23,652.00
23,652.00
23,652.00
23,652.00

EFEL,j,y
0.85234
0.85234
0.85234
0.85234
0.85234
0.85234
0.85234
0.85234
0.85234
0.85234
0.85234
0.85234
0.85234
0.85234
0.85234

PEEC,j,y
2,520
9,660
15,120
5,040
20,160
20,160
20,160
20,160
20,160
20,160
20,160
20,160
20,160
20,160
20,160

Total 2013-2022

236,520.00

201,595

,t

2007

2008

Average

83,600.00

89,422.00

85,438.00

10,000.00

10,000.00

10,000.00

43,665,000.00

47,814,000.00

45,410,333.33

40,686,080.64

44,552,027.02

42,312,343.61

2015
20,160
23,652

2016
20,160
23,652

2017
20,160
23,652

2018
20,160
23,652

2019
20,160
23,652

2020
20,160
23,652

2018

2019

2020

0.00171

2015

2016

2017

20,072
0.001711

19,149
0.001711

18,268
0.001711

17,428
0.001711

16,626
0.001711

15,861
0.001711

11,733.06

11,193.34

10,678.45

10,187.24

9,718.63

9,271.57

Cross-Check
Carbon content Carbon content Carbon content
of gas
of gas
of gas
kgC/kg
0.653
0.028
0.012
0.007
0.000
0.004
0.000
0.001
0.000
0.018
0.000
0.000
0.723

kgCO2/Nm3
1.328
0.109
0.067
0.055
0.000
0.038
0.000
0.015
0.000
0.100
0.000
0.000
1.711

tCO2/Nm3
0.00133
0.00011
0.00007
0.00005
0.00000
0.00004
0.00000
0.00001
0.00000
0.00010
0.00000
0.00000
0.00171

Table B.6.3.5. Project Emissions over 2010-2012


Period

CO2 Emissions from


fossil fuel combustion,
tCO2/y

CO2 emissions from


electricity consumption,
tCO2/y

y
2008
2009
2010
2011*
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022

PEfc,j,y
3,040
11,702
20,826
6,058
23,118
22,055
21,040
20,072
19,149
18,268
17,428
16,626
15,861
15,132
14,436

PEEC,j,y
2,520
9,660
15,120
5,040
20,160
20,160
20,160
20,160
20,160
20,160
20,160
20,160
20,160
20,160
20,160

Total 2013-2022

180,068

201,595

2021
20,160
23,652

2022
20,160
23,652

2021

2022

total 2013-2022
201,595

Total 2013-2022

15,132
0.001711

14,436
0.001711

8,845.08

8,438.20

Project emissions

PEy
5,560
21,362
35,946
11,098
43,278
42,214
41,200
40,232
39,309
38,428
37,587
36,786
36,021
35,291
34,595
381,664

180,068
0.001711
105,256.20

PDD No.
1
2
3
4
5
6
7
8
9

Formulae

BEy = VF,y * NCVRG,F,y * EFCO2, Methane


PEy = PE FC,y + PE EC, y
PE FC,y = FC i,y * COEF i,y
PEEC,y = EC PJ,y * EF EL,y * (1+TDLy)
ER y = BE y - PE y
COEF i,y = w C,i,y * i,y * 44/12
FC i,y = V F,y * k
EF EL,y = (FCn,i,t * NCV i,t * EFCO2,i,t) / EGn,t
EFCO2,i,t = COEF i,y / NCV i,t

Determines parameter
Baseline emissions during the period y
Project emissions in the period y
CO2 emissions due to consumption of fossil fuels
CO2 emissions due to consumption of electricity
Emission reductions during the period y
CO2 emission coefficient of fuel type i in year y
Quantity of associated gas combusted in compression process during
the year y
Emission factor for electricity generation in year y
CO2 emission factor of fossil fuel type i used in the period t

Gas volume conversion factors for different conditions


Gas
temperature
and pressure

Temperature conversion factors

0 & 760 torr

15 &
760 torr

20 & 760
torr

15 & 1 bar

1.055

1.073

1.069

0C

15 &
760 torr
20 & 760
torr (standard
conditions)

0.948

1.017

1.013

15C

0.932

0.983

0.996

20C

15 & 1 bar

0.936

0.987

1.004

0 & 760 torr


(normal
conditions)

Pressure Units
technical
atmosphere
atmosphere
torr (torr)
(atm)
(at)
1 N/m2
105
1.0197105
9.8692106
7.5006103
1 Pa
100,000
1.0197
0.98692
750.06
106 dyn/cm2
1 bar
98,066.50
0.98067
1 kgf/cm2
0.96784
735.56
1 at
101,325
1.01325
1.0332
1 atm
760
1 atm
133.322
1.3332103
1.3332103
1.3595103
1.3158103
1 torr
6,894.76
68.948103
68.948103
70.307103
68.046103
1 psi
Example reading: 1 Pa = 1 N/m2 = 10^5 bar = 10.19710^6 at = 9.869210^6 atm, etc.
pascal (Pa)

bar (bar)

pound-force
per square
inch (psi)
145.04106
14.5037744
14.223
14.696
19.337103
1 lbf/in2

mperature conversion factors


K

273.16

288.16
293.16

S-ar putea să vă placă și