Sunteți pe pagina 1din 5

LowViscosity Housing- Coalescer

LVH-C

Description
The LowViscosity- Housing Coalescer
LVH-C is mainly used for the dewatering
of diesel. It is especially suitable for
applications with large amounts of water
that need to be removed in just a single
pass.
The Optimicron-Coalescer- and
separator elements ensure that a high
volume of water will be separated within
just a single pass.
Available in various sizes, the housings
can be optimally integrated into new or
existing systems.
The filters are designed according to the
AD2000 German rules and regulations for
pressure vessels or according to ASME.

Technical specifications
General data

Material housing
Max. operating pressure
INLET connector
OUTLET connector

Stainless steel or Carbon steel


10 bar
DN 50 300
DN 50 300

Operating temperature
Ambient temperature
Material of sealings

50 C maximum
50 C
FKM (FPM, Viton)

Filter elements

Filter elements used

Optimicron Diesel

Applications

Diesel dewatering of large flow rates.

The advantages to you

Excellent filtration performance in a


single pass
Low pressure loss due to innovative
element technology
Easy to service thanks to intelligent
element design
Easy to adapt to filter housings for
the removal of fine particles in diesel.

E 76590 LVH-CD en 2014-06-16.doc

D 7.659.0

1/5

Model code

Scope of delivery
LVH C D 4 40 E V B V F D32 /-ZA

Type
LVH = LowViscosity Housing

LVH-CD (without filter elements)


Installation and Maintenance
Instructions
Filter elements must be ordered
separately and installed before initial
operation on site.

Function
C = Coalescence
Operating fluid
D = Diesel

Accessories

Filter Size
4 = 4 Coalescing elements + 3 Seperation elements
6 = 6 Coalescing elements + 4 Seperation elements
9 = 9 Coalescing elements + 6 Seperation elements

Designation
Automatic Drain Kit,
consist. of:
- Level indicator
- Electric control
- Drain valve

Part no.:

Filter element length


40 = 40

Coalescing element 40"

xxxxxxxx

Designation
N42ON-DCZ-CA60F
*) on request

Housing material
E = Stainless steel
N = Carbon steel

Part no.:
3910257

Separation element 30"

Version
V = vertical

Designation
N32ON-DSZ-SA80F
*) on request

Pressure range
B = 10 bar

Part no.:
3910259

Hydraulic diagram

Hydraulic connection
L = DIN DN 50
T = DIN DN 100
V = DIN DN 150
W = DIN DN 200
Y = DIN DN 300

802
809

Material of sealings
F = FKM (FPM, Viton)

803

100

Clogging indicator
C12 = Differential pressure indicator, electrical
D17 = Differential pressure indicator, visual/electrical (230V)
D18 = Differential pressure indicator, visual/electrical (24V)
D32 = Differential pressure indicator, visual/electrical (PVL2GW.0/-V-113)
D33 = Differential pressure indicator, visual/electrical (PVL2GW.0/-111-16)
Z = without Clogging Indicator

600

808
804

Supplementary details
ZA = Certification (ASME certification)

801
Filter calculation
Filter Size

Maximum
flow rate

Number of
coalescing
elements

Number of
seperations
elements

LVH-CD-4 40
LVH-CD-6 40
LVH-CD-9 40

800 l/min
1200 l/min
1800 l/min

4 pcs.
6 pcs.
9 pcs.

3 pcs.
4 pcs.
6 pcs.

Weight
when
empty
(kg)
500
580
780

Housing
volume
(Liter)
470
670
1225

Item
100
600
801
802
803
804
808
809

E 76590 LVH-CD en 2014-06-16.doc

D 7.659.0

Designation
Filter housing
Clogging indicator (Option)
Inlet (IN)
Outlet (OUT)
Drain, clean side (DRAIN)
Drain, contaminated side
(DRAIN)
Measurement point (IN)
Measurement point (OUT)
2/5

Dimensions LVH-CD-4 40

All dimensions in mm.


Item
9
100
600
801
802
803
804
805
806
808
809
810
811
812
815

Designation
Type label
Filter housing
clogging indicator (optional)
Inlet (IN)
Outlet (OUT)
Drain, clean side (DRAIN)
Drain, contaminated side (DRAIN)
Cover lifting device
Eyelets for transportation / Lifting eyes
Measurement point (IN)
Measurement point (OUT)
Air bleed
Outlet Water
Drain Housing
Maintenance space for changing the filter elements

E 76590 LVH-CD en 2014-06-16.doc

D 7.659.0

3/5

Dimensions LVH-CD-6 40

All dimensions in mm.


Item
9
100
600
801
802
803
804
805
806
808
809
810
811
812
815

Designation
Type label
Filter housing
clogging indicator (optional)
Inlet (IN)
Outlet (OUT)
Drain, clean side (DRAIN)
Drain, contaminated side (DRAIN)
Cover lifting device
Eyelets for transportation / Lifting eyes
Measurement point (IN)
Measurement point (OUT)
Air bleed
Outlet Water
Drain Housing
Maintenance space for changing the filter elements

E 76590 LVH-CD en 2014-06-16.doc

D 7.659.0

4/5

Dimensions LVH-CD-9 40

All dimensions in mm.


Item
9
100
600
801
802
803
804
805
806
808
809
810
811
812
815

Designation
Type label
Filter housing
clogging indicator (optional)
Inlet (IN)
Outlet (OUT)
Drain, clean side (DRAIN)
Drain, contaminated side (DRAIN)
Cover lifting device
Eyelets for transportation / Lifting eyes
Measurement point (IN)
Measurement point (OUT)
Air bleed
Outlet Water
Drain Housing
Maintenance space for changing the filter elements

Note:
The information in this brochure relates to
the operating conditions and applications
described.
In the event of deviating applications
and/or operating conditions, please
contact the respective HYDAC department
concerned.
Subject to technical modifications.
HYDAC FILTER SYSTEMS GMBH
Industriestrae
66280 Sulzbach / Saar
Germany
Telephone:+49 (0)6897 / 509-01
Fax:
+49 (0)6897 / 509-9046
Internet: www.hydac.com
E-mail:
fltersystems@hydac.com

E 76590 LVH-CD en 2014-06-16.doc