SUMMARY. The method of the finite element allows us to observe the geometry of the specimen, the mechanical properties of the materials employed and the load conditions and frontier of the pattern. We analyzed the femur of a healthy
27 years old man. Our conclusion is that the femur works predominantly in loads of compression and secondarily in
flexion.
12,14,15,20
13
Reaccin de la cadera
3 Abductores
Reaccin de la cadera
13
20Abductores
Iliopsoas
47
9
Tracto-Iliotibiales
Y
Figura 1. Condiciones de carga para un fmur en la fase de apoyo medio (Taylor y cols. 199619).
A
Figura 2. Diagrama que muestra los cortes tomogrficos realizados al
fmur izquierdo de un voluntario.
REV MEX ORTOP TRAUM 2001; 15(1): 13-20
Modelo tridimensional de un fmur humano por medio del mtodo del elemento finito
Z
Y
3
11
4
2
10
12
9
5
13
16
14
6
15
Figura 5. Construccin del modelo del fmur a partir de las reas definidas a partir de los keypoints. A) Lneas. B) Volmenes. C) Elementos finitos.
REV MEX ORTOP TRAUM 2001; 15(1): 13-20
15
Z
Y
A
Figura 8. Malla de elementos finitos. A) Vista inferior. B) Vista superior
Resultados
El cuadro 1 muestra los desplazamientos Ux, Uy y Uz obtenidos, as como los esfuerzos de von Mises mximo y mnimo,
cuando se aplican los casos de carga 1, 2, 3 y 4 antes descritos.
El eje X se orienta en sentido medial-lateral (de izquierda a derecha en la figura 9, 11, 12 y 13), el eje Y en sentido anteriorposterior y el eje Z es vertical, o sea, de abajo hacia arriba.
Se aprecia que en general, los desplazamientos son menores para 1, que para el resto de los casos. El efecto ms
16
Modelo tridimensional de un fmur humano por medio del mtodo del elemento finito
Caso
1
2
3
4
Desplazamiento (mm)
Ux
Uy
Uz
2.17
2.27
1.21
5.99
4.47
3.21
5.06
5.44
-2.26
-2.28
-2.85
-1.40
249.41
249.56
249.58
249.59
0.21
0.24
0.25
0.27
MX
SEQV (AVG)
DMX = .005638
SMN = 114549
SMX = .120E+09
114549
.135E+08
.268E+08
.401E+08
.535E+08
.668E+08
.802E+08
.935E+08
.107E+09
.120E+09
Z
Y
SEQV (AVG)
DMX = .005638
SMN = 114549
SMX = .120E+09
114549
.135E+08
.268E+08
.401E+08
.535E+08
.668E+08
.802E+08
.935E+08
.107E+09
.120E+09
Figura 9. Esfuerzos de von Mises y desplazamientos para el modelo del fmur. Caso 1.
REV MEX ORTOP TRAUM 2001; 15(1): 13-20
17
SEQV (AVG)
DMX = .005638
SMN = 114549
SMX = .120E+09
114549
.135E+08
.268E+08
.401E+08
.535E+08
.668E+08
.802E+08
.935E+08
.107E+09
.120E+09
MX
Z
Y
SEQV (AVG)
DMX = .003665
SMN = 111912
SMX = .120E+09
111912
.135E+08
.268E+08
.401E+08
.535E+08
.668E+08
.802E+08
.935E+08
.107E+09
.120E+09
Z
Y
Figura 11. Esfuerzos de von Mises y desplazamientos para el modelo del fmur. Caso 2.
REV MEX ORTOP TRAUM 2001; 15(1): 13-20
SEQV (AVG)
DMX = .003665
SMN = 111912
SMX = .120E+09
111912
.135E+08
.268E+08
.401E+08
.535E+08
.668E+08
.802E+08
.935E+08
.107E+09
.120E+09
18
Modelo tridimensional de un fmur humano por medio del mtodo del elemento finito
SEQV (AVG)
DMX = 006899
SMN = 108716
SMX = .799E+08
108716
.897E+07
.178E+08
.267E+08
.356E+08
.444E+08
.533E+08
.621E+08
.710E+08
.799E+08
Z
Y
SEQV (AVG)
DMX = 006899
SMN = 108716
SMX = .799E+08
108716
.897E+07
.178E+08
.267E+08
.356E+08
.444E+08
.533E+08
.621E+08
.710E+08
.799E+08
Z
A
X
B
X
Figura 13. Esfuerzos de von Mises y desplazamientos para el modelo del fmur. Caso 4
El caso 4 que se muestra en la figura 13, presenta el mayor desplazamiento en la proyeccin AP (Figura 13A), en
tanto que en la proyeccin lateral se observa que el desplazamiento es muy similar al caso 1. El patrn de esfuerzos resultante muestra una distribucin muy distinta a los tres anteriores casos. El mximo esfuerzo se localiza en la porcin ms
distal difisis, en la corteza lateral. De igual forma se aprecia
que los esfuerzos en esta zona son ms elevados que para el
resto de los casos estudiados. Los esfuerzos disminuyen desde su mximo hasta la porcin media de la difisis. En la porcin proximal-lateral de la difisis se aprecia una disminucin de los esfuerzos respecto a la misma zona del caso 3.
Discusin
No hay duda de que el papel de los msculos es esencial
no slo para la locomocin en s, sino adems que protege
al hueso de sufrir dao al producirse cargas fisiolgicas, ya
que su accin reduce el nivel de deformaciones que se presentan cuando ste es sometido a carga.
Los desplazamientos cambiaron apreciablemente si se
comparan los casos A y D. la diferencia en los desplazamientos es mayor 2.76 veces para Ux, 2.69 veces para Uy y
se reduce en un 38% para Uz. En la direccin y, no slo se
REV MEX ORTOP TRAUM 2001; 15(1): 13-20
19
5. Kang YK, Park HC, Youm Y, Lee IK, Ahn MH, Ihn JC. Three dimensional shape reconstruction and finite element analysis of femur
before and after the cementless type of total hip replacement. J Biomed Eng 1993; 15: 497-504.
6. Keyak JH, Rossi SA, Jones KA, Skinner HB. Prediction of femoral
load using automated finite element modeling. J Biomech 1998;
31(1): 125-133.
7. Keyak JH, Fourkas MG, Meagher JM, Skinner HB. Validation of an
automated method of three-dimensional finite element modeling of
bone. J Biomed Eng 1993; 15: 505-509.
8. Lotz JC, Cheal EJ, Hayes WC. Fracture prediction for the proximal
femur using finite element models: Part I - linear analysis. J Biomech
Eng 1991; 113: 353-360.
9. Mann KA, Ayers DC, Damron TA. Effects of stem length on mechanics of the femoral component after cemented revision. J Orthop Res
1997; 15: 62-68.
10. Mann KA, Bartel DL, Ayers DC. Influence of stem geometry on mechanics of cemented femoral hip components with proximal bond.
Transactions of 43rd Annual Meeting Orthopaedic Research Society,
San Francisco, 1997; 840.
11. Mann KA, Bartel DL, Wright TM, Burstein AH. Coulomb frictional
interfaces in modeling cemented total hip replacements. J Biomech
1995; 28(9): 1067-1078.
12. Mann KA, Edidin AA: Feasibility of a shortened femoral stem component: A parametric study. Transactions of 43rd Annual Meeting
Orthopaedic Research Society, San Francisco, 1997; 836.
13. Marom SA, Linden MJ. Computer aided stress analysis of long bones
utilizing computed tomography. J Biomech, 1990; 23(5): 399-404
14. McNamara BP, Cristofolini L, Toni A, Taylor D. Relationship between bone-prosthesis bonding and load transfer in total hip reconstruction. J Biomech 1997; 30(6): 621-630.
15. Namba RS, Keyak JH, Kim AS, Vu LP, Skinner HB. Cementless implant composition and femoral stress. A finite element analysis. Clin
Orthop 1998; 347: 261-267.
16. Prendergast PJ. Finite element models in tissue mechanics and orthopaedic implant design. Clin Biomech 1997; 12(6): 343-366.
17. Rohlmann A, Mssner U, Bergmann G, Klbel R. Finite-elementanalysis and experimental investigation in a femur with hip endoprosthesis. J Biomech 1983; 16: 727-742.
18. Rohlmann A, Bergmann G, Kelbel R. The relevance of stress computation in the femur with and without endoprostheses. En: Gallagher RH, Simon BR, Johnson PC y Gross JF. Finite Elements in Biomechanics. John Wiley & Sons, 1982: 361-377
19. Taylor ME, Tanner KE, Freeman MAR, Yettram AL. Stress and strain distribution within the intact femur; compression of bending? Med
Eng & Physics 1996; 18(2): 122-131.
20. Van Rietbergen B, Mller R, Ulrich D, Regsegger P, Huiskes R.
Quantitative assessment of tissue loading in proximal femur, using a
full scale microstructural FE-model. Transaction of 43rd Annual
Meeting Orthopaedic Research Society, 1997; 62.
21. Yao MS, Wang CJ, Yettram AL. The role of the cortical bone around
the head of the femur under various load cases. Transaction of the
11th Conference of the European Society of Biomechanics, Toulouse
France, 1998; 74.
Conclusiones
Reproducir la geometra de un fmur es todo un reto
para los analistas de esfuerzos. Resulta de mucho valor tener acceso a un tomgrafo computarizado. A travs de las
imgenes capturadas por este equipo es posible reconstruir
con precisin la intrincada geometra del fmur.
Los modelos tridimensionales de elementos finitos suelen ser muy demandantes en lo que respecta a capacidad de
cmputo. En general se considera que el empleo de una estacin de trabajo se justifica plenamente para nuestro caso,
en particular dado que el modelo desarrollado es relativamente complejo. Una computadora personal sera muy lenta con un problema de este tipo, y posiblemente no tenga la
capacidad necesaria para resolverlo.
Los casos 1 (que incluyen los msculos M, Z y P, adems de la reaccin de la cadera, R) y 2 (M y R) provocan
que el fmur trabaje predominantemente en compresin, en
tanto los casos 3 (M, P, R) y 4 (slo R) predicen comportamientos atpicos del fmur, en especial el Caso 4, el cual
causan que el hueso trabaje predominantemente a flexin.
El presente estudio es fundamental para conocer el comportamiento del fmur en tres dimensiones, cuando a ste se
le somete a cargas fisiolgicas.
Bibliografa
1. Brekelmans WAM, Poort HW, Slooff TJ. A new method to analyze
the mechanical behaviour of skeletal parts. Acta Orthop Scand 1972;
43: 301-317.
2. Cody DD, Hou FJ, Fyhrie DP. Automated FEMs from QCT data estimate proximal femur stiffness changes over time in-vivo. Transactions of 43rd Annual Meeting Orthopaedic Research Society, San
Francisco, 1997: 856.
3. Huiskes R, Chao EYS. A survey of finite element analysis in orthopaedic biomechanics: The first decade. J Biomech 1983; 6(2): 385-409.
4. Huiskes R, Verdonschot N, Nivbrant B. Migration, stem shape, and
surface finish in cemented total hip arthroplasty. Clin Orthop 1998;
355: 103-112.
RESUMEN. El mtodo del elemento finito nos permite observar la geometra del espcimen, las propiedades mecnicas de los materiales empleados y las condiciones de carga y frontera del modelo. Analizamos el fmur de un individuo
masculino sano, de 27 aos. Nuestra conclusin es que el fmur trabaja predominantemente en cargas de compresin y
secundariamente en flexin.
Palabras clave: modelo, fmur, elemento finito, mtodo, anlisis, computacin.
20