Sunteți pe pagina 1din 4

BRUNNER WATER BOILERS

Kamin-Kessel 45/101
lifting doors
State: 25.02.2013

made in germany

Dimension sheet | Kamin-Kessel 45/101 lifting doors

VL

supply 1"

RL

return boiler 1"

drain 1/2"

SVL

supply cooling pipe outlet

SRL

return cooling pipe outlet

FTAS

socket for thermometer cooling

TF1

socket 1/2" for thermometer

TF2

socket 1/2" for thermometer

with mounting frame 50 mm

VL

supply 1"

RL

return boiler 1"

drain 1/2"

SVL

supply cooling pipe outlet

SRL

return cooling pipe outlet

FTAS

socket for thermometer cooling

TF1

socket 1/2" for thermometer

TF2

socket 1/2" for thermometer

with mounting frame 70 mm

We suggest for CAD planing Palette CAD. Permanent updated drawings: www.brunner.de
Frames / front versions are marked colored.
Art.-Nr I019490 flue gas adapter for horizontal outlet (E= 250mm / A= 200mm)

Dimension sheet | Kamin-Kessel 45/101 lifting doors

VL

supply 1"

RL

return boiler 1"

drain 1/2"

SVL

supply cooling pipe outlet

SRL

return cooling pipe outlet

FTAS

socket for thermometer cooling

TF1

socket 1/2" for thermometer

TF2

socket 1/2" for thermometer

with door frame

We suggest for CAD planing Palette CAD. Permanent updated drawings: www.brunner.de
Frames / front versions are marked colored.
Art.-Nr I019490 flue gas adapter for horizontal outlet (E= 250mm / A= 200mm)

Planning and installation


Kamin-Kessel 45/101
Tested according to

EN 13229 W

Data for functional demonstration


Rated heat power
Firewood consumption
Combustion performance
Flue gas mass flow
Outlet temperature (before heating surface)
Flue gas temperature after
attached steel smoke hood
adjoining cast iron radiator (GNF10)
accumulation rings (MAS) 1)
adjoining ceramic accumulator 2)
ceramic modular accumulator (KMS system)
water boiler
Necessary supply pressure
Combustion air consumption
Combustion air connection

EN 13229 W

kW
kg/h
kW
g/s
C

19
5,2
23
15

6
24,5
21,5

C
C
C
C
C
C
Pa
m/h
mm

170
12
45
125

200
15
55
125

15 / 40 / 35
45 - 50

15 / 40 / 35
45 - 50

Heat distribution
Insert / heating surface
Glass (single / double)
Boiler

%
%
%

Cross-section of gratings for max. warm air power


Supply air
Warm air

cm
cm

400
400

400
400

Space inside oven chamber


Distance to oven chamber wall
Distance to floor

cm
cm

6
2

6
2

cm
cm
cm
cm

2
0
10
10

2
0
10
10

bar
C
litres
inch

3
100
55
1

3
100
55
1

Heat insulation without / with


Wall
Floor
Ceiling
Brick lining of protected walls

3)

air gratings

Water boiler data


max. operating pressure
max. flow temperature
Water volume
Connections flow / return
Weight
Fireplace + burning chamber

4)

meets requirement limit values for


Germany / Austria / Switzerland / Norway

182 + 154 + 89

kg

1.BlmSchV (Stufe 2) / 15. BVG / LRV / -

1) Throttle flap recommended


2) Approximate value, must be calculated eventually
3) Values with air gratings, stove casing is heat conducting
4) heater = body + mounted exchanger

Ulrich Brunner GmbH


Zellhuber Ring 17 -18
D-84307 Eggenfelden
Phone: +49 / (0)87 21 / 7 71-0
Fax: +49 / (0)87 21 / 7 71-100
info@brunner.de | www.brunner.de
BRUNNER products are offered and sold only by qualified dealers and service centres.
Subject to technical and assortment changes. Errors excepted. (02/13)