Sunteți pe pagina 1din 9

Name: Christian Moreau Object: IG-04-6212-2.

04 Date: 31 march 09

Design Control
TIS

System
Used on
ALU
W-CDMA

4.

3.

2.

1.

CM

APPD

This is the preliminary issue


of 04-6212-2.01
Issue -2.02 after internal
review
Issue -2.03 internal review
and official naming
Issue-2.04: Add Plinth

31-03-09

DRW

Alcatel-Lucent

04-6212-2.04 Preliminary
of 9 1 of 9
Alcatel-Lucent
04-6212-2.04 PreliminarySheet 1Sheet

Installation Guide AlcatelAlcatel


LucentLucent
9312 Compact
SmartSmart
NodeB
MBI3+
9312 Compact
inin
MBI3+

Alcatel-Lucent PROPRIETARY
This document contains proprietary information of Alcatel-Lucent and is not to be disclosed
or used except in accordance with applicable contracts or agreements
CC
2009
Alcatel-Lucent ANDAllCOPYRIGHT
Rights Reserved
SEE
PROPRIETARY
NOTICE ON COVER PAGE

Warning: In accordance with standard practice, cables must be installed so


that individual modules can be easily replaced without having to remove the cables.

Note: For handling, securing and site preparation requirements refer to:
3BK 17417 3045 RJZZA Document.
This document only covers W-CDMA modules/cables in the installed MBI3+

NodeB in MBI3+

Alcatel-Lucent 9312 Compact Smart

Installation Guide

Date
Issued

DRW
Issue

Name: Christian Moreau Object: IG-04-6212-2.04 Date: 31 march 09

4 screws

3 screws on each side

4 screws

D
TRDU:
3JR21002AA

B
KIT: BRACKET OMK10
3JR08827AA

C
9326 d2U v2
NTYD0608

3JR08814AA

A
TRDU Subrack :

1. Mechanical Installation Without Optional Module

KIT: Plinth 3BK26474AACA

Alcatel-Lucent

04-6212-2.04 Preliminary

Sheet 2 of 9

Alcatel Lucent 9312 Compact Smart in MBI3+

SEE PROPRIETARY AND COPYRIGHT NOTICE ON COVER PAGE

1U

Final location

Note: Perform the installation step in the correct order:


start with A, followed by B, then C, and finally D

Name: Christian Moreau Object: IG-04-6212-2.04 Date: 31 march 09

Bulkhead MBI3+ Antenna

2.RF and Power Cabling

Ref

3BK07921AAAA

5
SOC-CS04ANX/ANT
CSET Indoor

TRCU power

OMK10

Remark

TRDU1 Power in
TRDU2 Power in
TRDU3 Power in

J3 TRDU
J3 TRDU 2/5
J3 TRDU 3/6

TRDU5 Power in
TRDU6 Power in

J3 TRDU 2/5
J3 TRDU 3/6

TRDU4 Power in

J3 TRDU

Torque wrench to 25 Nm

TRDU

TRDU ICO 2

3JR22039AA

TRDU

3JR22039AA

2 RF cables per Kit

One per TRDU

In future User ICO

Only if the second


TRDU ICO is used

Cables connected on
the DC Breaker

TRDU ICO 1

Up to 6

Up to 6

Qty

Alcatel-Lucent

04-6212-2.04 Preliminary

Sheet 3 of 9

Alcatel Lucent 9312 Compact Smart in MBI3+

SEE PROPRIETARY AND COPYRIGHT NOTICE ON COVER PAGE

SR1

DC Breaker MBI3+

3JR22040AA

DC/user ICO

3JR22067AA
TRDU power

GND Cable
DC/TRDU ICO

3BK27904AA

3JR22039AA

Designation
DC/TRDU ICO and
d2U POWER IN

3JR22065AA

3JR22066AA

Name: Christian Moreau Object: IG-04-6212-2.04 Date: 31 march 09

10

3JR22051AA
3JR22031AA
3JR22036AA
1AB382920001

7
8
9
10

1
1

Adaptor xCCM-U IUB/Ext PCM Evo


RUC/TRCU alarm cable

TRDU 3 Data I/O


TRDU 4 Data I/O
TRDU 5 Data I/O
TRDU 6 Data I/O

Optic 3
Optic 4
Optic 5
Optic 6

TRDU 2 Data I/O

Optic 2

Bulkhead MBI3+

TRDU 1 Data I/O

Optic 1

1AB382920001

BULK IND EVO/XCCM IUB

Up to 6

RUC/xCCMu cable

CPRI cable

Qty

Designation

Alcatel-Lucent

04-6212-2.04 Preliminary

Sheet 4 of 9

Alcatel Lucent 9312 Compact Smart in MBI3+

SEE PROPRIETARY AND COPYRIGHT NOTICE ON COVER PAGE

Warning

3JR22028AC

Ref

PCM

3.PCM and Digital Cabling

Alarm ext

Name: Christian Moreau Object: IG-04-6212-2.04 Date: 31 march 09

13

11

3JR22036AA
3JR22038AA

9
11

1
1
1
1
1
1
2

RUC/xCCMu cable
BULK IND EVO/XCCM IUB
Adaptor xCCM-U IUB/Ext PCM Evo
RUC/TRCU alarm cable
TRCU Alarm out/d2U
GND M6
Bulk evo ind/IEAM Alarm

Bulkhead MBI3+

Qty

Designation

Alcatel-Lucent

04-6212-2.04 Preliminary

Sheet 5 of 9

Alcatel Lucent 9312 Compact Smart in MBI3+

SEE PROPRIETARY AND COPYRIGHT NOTICE ON COVER PAGE

12

3JR22053AA

3JR22031AA

13

3JR22051AA

3BK27904BA

3JR22028AC

12

Ref

PCM

4.Solution with Optional IEAM Module

Alarm ext

13

Bulkhead MBI3+

PCM

Name: Christian Moreau Object: IG-04-6212-2.04 Date: 31 march 09

14

15

5.Solution with Optional IEAM+ LPPCM Module

Alarm ext

11

3JR22028AC
3JR22051AA
3JR22036AA
3JR22038AA
3BK27904BA
3JR22053AA
3JR22030AA
NTA595QF

6
7
9
11
12
13
14
15

12

PCM/ALARM MOD CO

LPPCM OUT/XCCM IUB

Bulk evo ind/IEAM Alarm

GND M6

TRCU Alarm out/d2U

RUC/TRCU alarm cable

BULK IND EVO/XCCM IUB

RUC/xCCMu cable

Designation

Qty

Alcatel-Lucent

04-6212-2.04 Preliminary

Sheet 6 of 9

Alcatel Lucent 9312 Compact Smart in MBI3+

SEE PROPRIETARY AND COPYRIGHT NOTICE ON COVER PAGE

Ref

Name: Christian Moreau Object: IG-04-6212-2.04 Date: 31 march 09

3BK25995HA

3BK08963HA

19

20

3BK05360CAAA or
3BK05360DAAA

3JR22054AB

18

22

NTBY60SF

17

3BK08964HA

3JR22052AA

16

21

Ref

16

Torque wrench to 25 Nm

22

22

21

RF cable
TRDU to antenna

GND Cable1X25mm

0Vblack cable 1x25mm DC

-48V blue cable 1x25mm DC

External alarm 16m

Inst PCM 120 ohms Ind2

Bulkhead Ind EVO PCM ext

Designation

17

Up to
12

Qty

6.Cabinet External Cabling Solution PCM 120 Ohms

18

DDF

GND Site

Customer
DC Box -48V

Alcatel-Lucent

04-6212-2.04 Preliminary

Sheet 7 of 9

Alcatel Lucent 9312 Compact Smart in MBI3+

SEE PROPRIETARY AND COPYRIGHT NOTICE ON COVER PAGE

* For #19, #20 use kit 3BK25913AC (lug, cable ties, screw etc)

19

20

Alarm

Tx/Rx

Name: Christian Moreau Object: IG-04-6212-2.04 Date: 31 march 09

3BK25995HA

3BK08963HA

19

20

3BK05360CAAA or
3BK05360DAAA

3JR22054AB

18

22

TBD

17

3BK08964HA

TBD

16

21

Ref

8 PCM Impedance
Adapter Box

Torque wrench to 25 Nm

22

22

21

RF cable
TRDU to antenna

GND Cable1X25mm

0Vblack cable 1x25mm DC

-48V blue cable 1x25mm DC

External alarm 16m

Ext PCM 75 ohms 16m

Bulkhead Ind EVO PCM box

Designation

17

Up to
12

Qty

16

18

DDF

Alarm

Tx/Rx

GND Site

Customer
DC Box -48V

Alcatel-Lucent

04-6212-2.04 Preliminary

Sheet 8 of 9

Alcatel Lucent 9312 Compact Smart in MBI3+

SEE PROPRIETARY AND COPYRIGHT NOTICE ON COVER PAGE

* For #19, #20 use kit 3BK25913AC (lug, cable ties, screw etc)

19

20

7.Cabinet External Cabling Solution 8 PCM Impedance Adapter Box

Name: Christian Moreau Object: IG-04-6212-2.04 Date: 31 march 09

Red

Blue

Red

Blue

Red

Blue

Red

Blue

Red

Blue

Red

Blue

Red

Blue

Red

Blue

Red

Blue

Red

Blue

Red

Blue

Red

Blue

Red

Blue

Red

Blue

Red

10

11

12

13

14

15

16

17

18

21

22

23

24

25

26

27

28

31

32

33

34

35

36

12

16

15

11

10

14

13

Pair

TX3-

TX3+

TX6-

TX6+

TX8-

TX8+

RX8-

RX8+

RX6-

RX6+

RX3-

RX3+

TX2-

TX2+

TX5-

TX5+

RX5-

RX5+

RX2-

RX2+

TX1-

TX1+

TX4-

TX4+

TX7-

TX7+

RX7-

RX7+

RX4-

RX4+

RX1-

RX1+

Signal

The following pins: 19, 20, 29, 30 and 37 are not connected

Red

Blue

Blue

Conductor Color

PCM Cable: NTBY60SF

Pin

8.Pin-Out

15

14

13

12

11

10

Alarm 8

Alarm 7R/Alarm 8R

Alarm 7

Alarm 6R

Alarm 6

Alarm 5R

Alarm 5

Alarm 4R

Alarm 4

Alarm 3R

Alarm 3

Alarm 2R

Alarm 2

Alarm 1R

Alarm 1

NAME OF SIGNAL

Red/Green

Orange/Red
Green/Red

Red/Orange

Blue/Red

Red/Blue

Grey/White

White/Grey

Brown/White

White/Brown

Green/White

White/Green

Orange/White

White/Orange

Blue/White

White/Blue

COLOURS

Alcatel-Lucent

04-6212-2.04 Preliminary

Sheet 9 of 9

Alcatel Lucent 9312 Compact Smart in MBI3+

SEE PROPRIETARY AND COPYRIGHT NOTICE ON COVER PAGE

Note: If the color pairs are not as specified, the supplier must provide an
amendment to the above table, giving the actual cable colors used. This
information must be supplied on a notice delivered with each cable

Twisted
pairs

Twisted
pairs

Twisted
pairs

Twisted
pairs

Twisted
pairs

Twisted
pairs

Twisted
pairs

Twisted
pairs

PINS

Alarm Cable: 3JR22054AB

S-ar putea să vă placă și