Product

OPERATION MANUAL

M o d e l - LT R O N - B T
Microprocessor-based Flow Totaliser

IMPORTANT NOTE: IN ALL SECTIONS, WHEN MULTIPLE KEY


FUNCTIONS ARE REQUIRED, THE FIRST KEY IS TO BE
PRESSED FIRST, AND KEEEPING IT PRESSED, THE SECOND
KEY HAS TO BE THEN PRESSED, TO GO INTO THE
PARTICULAR MODE. E.G. when S + key press instruction is
given, press S key first, and keeping it pressed, press the key with
another finger to get into setpoint change mode.
LTRON-BT WIRING DIAGRAM (UNUSED OPTIONS WILL BE IN
BLANK CUTOUTS)
Notes
1. NC-P1-NO denote Normally Closed/Phase (Pole)/Normally open
conditions of the relays. These can be configured in failsafe mode
(NO contacts can be programmed and made to be energized as per
High or Low limit requirement see Section II Operation).
2. Terminals shall be provided as per order for no. of relays and
optional feature (Retransmission and Communication port)

CONTENTS
1) Introduction
2) Unpacking & Installation
1.
3) Specifications
4) Programming
5) Connection Diagram
FEATURES
NEW from cost effective LTRON SERIES FAMILY
Microprocessor based
Site Programmable-Program it, Fit it, Forget it!
Compact Size- 96 x 96 x 100 mm
Main inputs (linear/sqrt 0/4-20mA,0/1-5VDC,0-10VDC)
Up to 4 on-off relay outputs with C/O contacts
4-key tuctile key board for programming
24 VDC output to Power Transmitters
Isolated RS-485 serial port Option
Isolated 4-20 mA Re- Transmission output option

BATCH START MODE


To start the totalisation of the flow values press M + keys together.
Enter correct password (Password Facility if specified), press S key
to enter in to the batch start mode with lower display showing Str
bACH and upper display displaying the starting batch 0001.Press M
key to start the totalization of the flow value.
CALIBRATION PARAMETERS
Calibration parameters for 0-5,1-5,0-10V DC and 0/4-20 mA/sqrt are
stored independently.
QUICK CALIBRATION MODE (Quick-Cal)
The LTRON-BT can be quickly calibrated for its input by adopting the
following procedure. First configure the instrument for required input
(e.g., mA). Enter into Input ZERO side calibration Mode (see section
IV), and press S + together. The input automatically gets
calibrated to the user configured Range Lo. Similarly repeat the
same procedure for input SPAN side calibration.Fine calibration may
be further required.

1. INTRODUCTION
LTRON-BT FLOW TOTALISER are part of Lectroteks LTRON-series
MICROPROCESSOR-based Process Measurement and Control
products. The instruments are innovative in terms of compact size
(1/4 DIN & 1/8 DIN versions) and cost-effective, yet full-featured in
terms of ease of use, programmability, optional communication port
and re-transmission signal output. It has full keyboard based
operation for programming inputs, ranges, decimal point, linear or
square root input selection and calibration.
The LTRON-BT accepts 0/4-20 mA (linear/square-root), 0/1-5VDC,
0-10VDC inputs and is useful for all general purpose measurement.
The instruments compact and highly functional fascia consists of a
16 digit, 7-segment LED display and 4-key tuctile keyboard for
programming/parameter selection purposes. RS-232 or Rs-485 ports
are optional for communication with DAS/SCADA systems. An
isolated 4-20 mA re-transmission signal is also optional, and can be
used for recording purposes or remote signal transmission to
DAS/PLC/DCS systems.
The enclosure is a 96x96x100 mm (WHD) sized engineering plastic
enclosure suitable for mounting in panel cutout of 92 x 92 mm DIN
size, via 2 clamps. The instrument has an IP-40 front facia and IP40
rear.
2. UNPACKING & INSTALLATION
Unpack the instrument and check for presence of this Operation
Manual, pair of clamps and physical damage if any. Report to the
dealer for any shortages or warranty service/replacement.
Install the instrument on the panel in a cutout as per the instrument
1.) Connect 0/4-20mA/sqrt between terminal 1 and 3 (with 1 as
+ve & 3 as - ve)
2.) Connect 0-5,1-5,0-10V DC between terminal 5 and 4 (with 5
as +ve & 4 as ve) (optional)
3.) Earth must be provided.

LECTROTEK SYSTEMS PVT. LTD.


33 Parvati Industrial Estate, Pune411009, India
Tel. +91-20-24220313/24220383
Fax: 4223932 ,Email:
sales@lectrotek.com
Visit www.lectrotek.com

WARRANTY
LECTROTEK SYSTEMS
D IMonths
G I TALafter
I N Pdispatch
UTS O
ER
ATI O after
N commissioning, whichever
18
orP12
Months
33, PARVATI
INDUSTRIAL
ESTATE,
digital
inputs
(D1 & D3) are
provided
to start
and stop
isTwo
earlier,
against
manufacturing
defects,
ex-works
/ dealer.
PUNE 411009
(INDIA)
the
batch.
These
inputs
are
configured
so
as
to
accept the
Refer to company for detailed warranty terms.
LECTROTEK .Your
Process
Control
Instrument Systems Expert SINCE 1970
VOICE
91
20 24220383
event
on falling
edges
and:low
levels.
input
of pulse
No
implied
warranty
applicable
other
thanDigital
company
standard
warranty
Page 1 of 3
FAX
: 91 20 24223932

width more than 100 mSec on pin D1 will stop the batch flow.
SALES@LECTROTEK.COM
Batch will start if EMAIL
and only :if there
is event on pin D3.
URL

WWW.LECTROTEK.COM

www.lectrotek.com