Sunteți pe pagina 1din 2

Evolant Solutions

Data sheet

Armored fiber optic buried cable


with 72 single-mode fibers E9/125 SMF 28e+

Loose buffer tubes, nom. diam.


2,25mm, with 12 fibers, filled
Rip cords
Central member, metal free
Swellable elements
Corrugated steel tape
Outer jacket, PE, nom.
thickness 1,3 mm

Principle drawing

A-DQ(ZN)(SR)2Y 6x12 E9/125 0.36F3.5 + 0.22H18 LG


Design and special properties
Thin and robust cables
Cables for direct burial, in applications with high mechanical loads and in areas with rodents
Corrugated steel tape as protection against rodents and mechanical damage
Dry cable core by swellable elements Single-layer stranded construction, S/Z stranding
The tubes are filled with a paraffin oil based non-hygroscope, non-nutritive fungus, electrically
non-conductive, homogenous gel in order to prevent water penetration and migration.
Outer PE-jacket, UV resistant
Single mode fibers fully compliant to standard ITU G.652 D (reduced OH- peak) showing
low attenuation throughout the 1285 nm to 1625 nm wavelength range
Customer standard for fiber and loose tube coloring
Cable design according to Customer standard

Archive: CCS EMEA AE


Datasheet: 12-07-18 A-DQ(ZN)(SR)2Y 6x12E9 2,25mm LG SAP 563397 e.doc

CCS reserves the right to improve, enhance, and modify the features and
specifications
of
CCSs
products
without
prior
notification.
The
information
in this data sheet has been reproduced in good faith and is accurate, to the
best of CCSs knowledge, at the time of printing. However, CCS makes no
warranty as to, and will not be liably on any basis for, the information
contained within this data sheet.

1/2

Evolant Solutions
Data sheet
Coloring
Fibers:
Tube:

red, blue, white, green, violet, orange, grey, yellow, brown, pink, black, turquoise
red, blue, white, green, violet, orange

Outer jacket:

black

Cable printing:
meter CORNING CABLE SYSTEMS KABEL OPTYCZNY year A-DQ(ZN)(SR)2Y 72J2D (6x12) CO
DRUBI 407 Var. 141

Method:

hot foil printing, white

Characteristics of fibers E9/125 SMF 28e+ - low water peak fiber Optical and mechanical:
Mode-field diameter at 1310 nm
[ m]
Cladding diameter
[ m]
Coating diameter
[ m]
Attenuation at 1310 nm
[dB/km]
Attenuation at 1550 nm
[dB/km]
Attenuation at 1383 nm
[dB/km]
Dispersion in the range 1285 to 1330 nm
[ps/(nm km)]
Dispersion at 1550 nm
[ps/(nm km)]
[nm]
Cable cutoff wavelength ( cc)
PMD Link Design Value
Ps/ km
*) Complies with IEC 60794-3:2001,Section 5.5, Method 1 ( m=20,Q=0,01%)
The fibers are fully in compliance with ITU-T G.652.D and annexes

Technical cable characteristics


Mechanical and environmental:
Crush strength
Impact ( 10 Nm, r= 300 mm )
(Attenuation increase fully reversible)
Temperature range
Laying and
installation
Operation
Transport and storage
Water penetration (0.1 bar / 24 h) acc. to IEC 794-1-F5
Cable type

No. of
fibers

No. of
tubes

A-DQ(ZN)(SR)2Y

9.2 0.4
125.0 0.7
242 5
0.36
0.22
0.36
3.5
18
1260
0.06*

[N/10 cm]
impacts

3000
3 at different places

[C]

-5 to 50
-40 to 70
-40 to 70

[m]

No. of
stranding
elements

Outer
[mm]

11,0

3
Max.Tensile
strength

[kg/km]

Min. bending
radius during
install. [mm]

126

255

2700

Weight

6x12

72

Delivery length
Delivery length up to 6 km

Archive: CCS EMEA AE


Datasheet: 12-07-18 A-DQ(ZN)(SR)2Y 6x12E9 2,25mm LG SAP 563397 e.doc

CCS reserves the right to improve, enhance, and modify the features and
specifications of CCSs products without prior notification. The information
in this data sheet has been reproduced in good faith and is accurate, to the
best of CCSs knowledge, at the time of printing. However, CCS makes no
warranty as to, and will not be liably on any basis for, the information
contained within this data sheet.

2/2