SVEL Group

dry-type transformers

www.svel.ru

History
Start-up of SVEL RsEnergrns plant 1st plant of SVEL Group, specialized in manufacturing of the cast resin dry-type transformers, voltage
classes are 6-10 kV, rated power is from 25 t 2500 kV.
Start-up production of dry-type current limiting reactors, 4000 , voltage
classes are up to 20 kV, inductive resistance is up to 2,0 ohm;

2003

2004

Realization of the first project n design and construction of unitized


transformer substation.
Designed and manufactured dry-type converter transformers
-3200/6 for zones with moderate cold climate outdoor installation
(possibility of exploitation at the ambient temperature up t minus 60);

2005

Obtained patent on dry-type current limiting reactors;


Obtained certificates of compliance of SVEL power equipment to Federal
norms of industrial safety and working conditions for objects of JSC Gazprom and JSC rnsnft.
Obtained certificate of compliance of the quality management system to
IS0 9001:2000;

2007

Start-up of the project n the onstruction of a new plant SVEL Power


Transformers, manufacturing oil-immersed transformers, voltage classes
are from 10 t 220 kV, rated power is from 2 500 t 250 000 kV.
Branch Offices were opened in the following cities: scow, St-Petersburg, Krasnoyarsk, Krasnodar and Kiv.

2008

Start-up of manufacturing of the unitized transformer substations and


factory-assembled switchgears SVEL switchgears.

2009

Start-up of manufacturing of SVEL Instrument transformers;

2010

Branch Offices were opened in Astana, Kazan and Novosibirsk;


Plant of metal structures was integrated into SVEL Group.
Designed and manufactured 250 000/220- the most powerful
oil-immersed transformer manufactured by SVEL Group before 2011.
Branch Office was opened in Khabarovsk

2011

BUSINESS CTIVITY
SVEL Group is a leader among national manufacturers of the electrotechnical equipment. It is a producer of power dry-type and oil-immersed transformers, provider of solutions in electric power
quality improvement and electric network protection.
SVEL Group is also taking advantage of its cutting
edge technologies to be a reliable provider in such
products as switchgears, packaged transformer substations, instrument transformers, circuit breakers and
disconnectors.
SVEL specialists solutions allow to produce the
equipment that assists enterprises in the reduction of
energy consumption up to 45%. Going forward, SVEL
Group will continue to make big steps in other MV, HV
and UHV equipment.
Manufacture of dry-type
transformers and currentlimiting reactors;
Manufacture of power oil
immersed transformers;
Manufacture of
Integrated switchgears,
transformer substations,
complete block
transformer substations;
Manufacture of current
and voltage transformers;
Manufacture
of transmission angle
and pipe towers, special
distribution steel towers;
Design and installation;
Manufacture
of circiut breakers and
disconnectors.

COMPANY PROFILE
Rosenergotrans is a first plant of SVEL Group in Russia, established in 2003. Plant develops and manufactures such products as:
ast resin dry-type transformers rated from 25 t
16 000 kV, voltage classes are up t 35 kV;
Dry-type current limiting reactors, rated up t 8
000 , voltage classes are up t 230 kV with inductive reactance from 0,1 t 2,5 hm.
ast resin dry-type transformers of and
series manufactured by SVEL Group may replace earlier
installed ones without any additional expenditures:
Oil-immersed transformers;
Sovtol transformers;
Dry-type transformers: , , ,
GDNN, GEAFOL, SGB, RESIBLOC, TRIHAL, TTA-RES
and others.
SVEL Group upon individual orders can make drytype transformers with air-barrier insulation rated up
t 12 500 kV, voltage classes are up t 35 kV and
transformers with amorphous metal cores from 25 to
2500 kVA, voltage classes are up to 35kV.
Experience, constant dialogue with customers, suppliers and innovations applied by SVEL Group, allow to
offer a reliable and qualitative product.
All products rrespond to GOST, IEC and EN.

QUALITY POLITICS
Company mission
We transform energy into life, creating unique solutions in the field of
electric power equipment in all the chain: from generation to consumption.
Principles that we follow to realize our company mission:

1. Customer requests and expectations a subject of our research


and embodiment.

Our aim - loyal customers, appreciating mutual relations with us.

2. Company personnel value 1.



We strive to create necessary conditions for the enjoyment from


work and full realization of each worker potential.

3. We eliminate the reasons of mistakes, not only their consequences.



We admit our mistakes, analyze and eliminate the reasons of their


occurrence.

4. Every step should be efficient.



We make decisions on the base of combination of the theoretical


knowledge, professional experience and objective data.

5. Our suppliers basis of our production quality.




Only companies, corresponding to our requirements concerning


the quality of production, terms of delivery and prices, can become
our suppliers.

6. There is no limit to perfection any work is carried out much better.


Constant improvement of carried out activity by means of training and
perfection of employees the guarantee of our success.
Top management undertakes the obligation to control the quality management system of the company and to improve constantly its effectiveness on the basis of the given principles, and also to control the compliance with legislation of the Russian Federation and other normative acts.

Benefits of SVEL dry-type transformers

Reduced on-load and no-load losses;


Reduced noise level;
Possibility of operation at the temperature range
up t 60;
Qualitative materials and components:
- electrotechnical steel with low specific losses;
- foil for windings is bought from the best manufacturers of Germany and Norway.

Advantages of Svel Group

Skilled staff;
Modern equipment with software and automated
technologies allow to carry out the complete cycle
of manufacture, reducing the human factor;
Flexibility of manufacturing process according to
the customers requirements;
Effective Quality System Management
QS (ISO 9001);
High production standards;
Warehouse of finished products with wide assortment of items;
Favorable geographical position;
High level of maintenance and warranty service.

AST-RESIN DRY-TYPE TRANSFORMERS


SVEL Group offers transformers for different applications:
Power distribution general-purpose transformers;
Service transformers for electric power stations
and other objects;
Converter transformers for direct-current drive in
metallurgical, drill, gas-and-oil producing and others branches of industry;
ransformers for converter installations of the
urban transport (subway, tramway, trolleybus);
ransformers for converters of the excitation system of turbo- and hydrogenerators.
Depending on the customer requirements, transformers can be of the following design versions:
Lft: HV winding inputs are on the left regarding the front (side of the rating plate);
Right: HV winding inputs are on the right regarding the front (side of the rating plate);
Up: inputs of the LV and HV windings are on the transformer upper cover;
Other design versions are up to the customer request.

Structure of the transformer designation:


-

/
Placement category according to GS 15150;
Climatic modification according to GS 15150;
Voltage of the HV winding, kV;
Rated pwer, kV;
Scope f application:
- service transformer;
- converter transformer;
Absence of letter - pwer distribution transformer;
Voltage regulation system:
presence of the OLTC;
Absence of letter - absence of the OLTC;
Type of cooling system:
= AN (Air Norm);
3 = ANAN (Air Norm/Air Norm);
= ANAF (Air Norm/ Air Force);
= Air Force at the enclosed design;
Type of the LV winding:
- split LV winding;
Absence of letter - nonsplit LV winding;
Number of transformer phases:
three phase transformer;
0 single phase transformer.

Classification of the climatic modifications:


zones with moderate climate (up t -40);
zones with moderate cold climate (up t -60);
zones with tropical climate.
Classification of the placement categories at the operation:
1 outdoor installation;
2 - installation under shed or in a room with the outside air inlet;
3 - installation in a closed room with air norm;
4 - installation in a closed room with a non natural regulation of the climatic conditions;
5 - installation in a closed room with high humidity.
Example of the transformer designation:

- 1600/10
Three phase dry-type transformer with air forced cooling of the protected design version, 1600 kV, with the HV
winding voltage of 10 kV, of climatic modification and the placement category is according to GS 15150-69.

hnical prmters of the cast-resin dry-type transformers


ransformer type

ypical power, kVA


Primary voltage *
(rated voltage of HV winding), kV

10-6300*
6

6,3

High voltage regulation (changing type, number of steps


and range of regulation)
Secondary voltage
(rated voltage of LV winding ), kV

Heat-resistance class (according to GS 52719-2007)

0,23

0,4

D/Y -11

Y/Y - 0
F
any

Degree of protection (according to GS 14254-96)

IP00-IP54
63 dB

Seismicity of the installation zone according to MSK-64


scale

up t 9 pints

Guaranteed period of operation

from 3 years

Service life

0,69

50; 60

Climatic modification (according to GS 15150-69)


The sound pressure level

10,5

Off-load tap changer 2 2,5%

Frequency, Hz
Winding connection group

10

not less than 30 years

Note: the main characteristics of transformers of 15-35 kV voltage class and power over 6300 kV are to be approved upon the individual customer request.

9
9

TH MAIN DVANTAGES OF AST-RESIN DRY-TYPE TRANSFORMERS

A high level of fire safety, therefore, transformer


stations may be placed close to energy sinks, that
significantly reduces losses at transferring the electric power in low voltage power supply networks.
Environmentally friendly. Oil absence in the transformer eliminates the risk of the environment pollution at oil leakage.
Safety operation. Windings are non-inflammable,
so they cant cause the fire.
Easy installation, because it doesnt require any extra measures of fire safety at site.
Minimal running costs, as there is no need in controlling or substituting the dielectric liquid.
Small dimensions give an opportunity to install transformer of bigger power in the existing transformer
chamber while reconstructing the substation.
High dynamic strength at short circuit currents.
Windings are not exposed to humidifying and contamination.
Enhanced reliability. High level of the impulse
strength of dry-type transformers allows not to install the overvoltage limiter.

10

BASIC PARTS OF THE TRANSFORMER DESIGN


The mgnetic core
is made of cold-rolled electrotechnical sheet steel
with a heat-proof coating. Stacking tchnology and
step-lap cutting provide low level of no-load losses.
Cutting of electrotechnical steel is carried out on the
automatic cutting line with the high cut accuracy.
High voltage windings
are made in section-layer form with the series connection of sections. HV winding is made of insulated
wire or foil on high accuracy coil-processing machines.
Vacuum resin filling of windings is carried out during a
completely automated process. Epoxy compound includes a number of components providing a good heat
emission, and also a high thermostability.
Low voltage windings
are made of foil on automatic winding machine
with simultaneous winding of interlaminar and frontal
insulation. Number of cooling ducts in the winding depends on the transformer power. Ducts are provided
with fiberglass profiles of a high heat resistance class.
Windings are covered with insulating enamels and
heat treated.
Transformer housing
provides necessary protection degree of the active part. It is made of steel construction with walls,
a bottom and a roof. The walls and the bottom have
vent holes, providing a normalized cooling level of the
transformer. Wide walls have access panels for access
to adjusting taps. All walls are detachable, that assures
visual inspection and maintenance service on a schedule date.
Transformers can be manufactured of the following
design versions:
Lft: HV winding inputs are on the left regarding
the front;
Right: HV winding inputs are on the right regarding
the front;
Up: inputs of the LV and HV windings are on the
transformer upper cover.
Other design versions are up to the customer request.
Transformers can have any protection class up to
IP54 included, n the clients request.

11

HUSING
The protection class of transformer, provided by its
housing, is indicated as IP code. The IP de consists
of two figures: the first indicates the transformer protection against the external penetration; the second
figure indicates the protection against the water. The
less figures the less requirements to the transformer
protection.
The first figure of code
Figure

Value of the equipment


protection
(against penetration
of solid bjects)

The protection value


for people
(against access
to the active part)

No protection

No protection

Dimter > 50 mm

By back of the hand

Dimter > 12,5 mm

By finger

Dimter > 2,5 mm

By tools

Dimter > 1 mm

By wire

Dustproof

By wire

Dust-tight

By wire

The second figure of code


Figure

Value of the equipment protection against the


external impact as a result of the water penetration

No protection

Vrtical water dropping: water drops dripping vertically


shouldnt have a harmful effect

Water dropping (nminal angle 15): water drops


dripping vertically shouldnt have a harmful effect,
when the housing deviates from the vertical position
to any side for an angle up t 15 included

Sprinkling: wter, sprayed as splashes in any direction


which is together with the vertical line comprise an
angle up to 60 included, shouldnt have a harmful
effect

mplete sprinkling: wter, sprayed as splashes on


the housing in any direction shouldnt have a harmful
effect

Jet effect: wter, guided to the housing as a jet from


any direction, shouldnt have a harmful effect

Strong jet effect

Short-term immersion

Short-term immersion

net

12

Temperature control device


Temperature control device is designed to control
the temperature mode of dry-type transformers. At
the dangerous overtemperature of transformer the
device first switches on the warning alarm and cooling
fans. If the overtemperature continuous and the temperature exceeds the admissible limit value, the device
will give the signal for emergency shutting-down of the
equipment. The temperature control device has four
channels to measure the temperature and four output
relays. Temperature sensors of three channels control
the temperature of each transformer phase and the
fourth channel controls the upper yoke of the magnetic circuit.
The device carries out the following functions:
At the overtemperature of 145 on any sensor the
relay warning acts and a spot indicator is lit on the
front panel warning.
At the overtemperature of 155 on any sensor the
relay overheating acts and the corresponding spot
indicator is lit.
At the overtemperature of 135 on any sensor the
relay coling acts and the fan is switched-on, when
the temperature decreases up t 110 the fan is
switched-off. To show functioning of the fan, the spot
indicator coling is located on the front panel.
Rlay fault sensor indicates the fault temperature
sensor(s) in any channel in case of breakdown or shortcircuit of sensor and also in case of anomalously fast
temperature rise (20/sc. or faster), that also means
a fault temperature sensor. The corresponding indicator is lit on the device front panel if any temperature
sensor is defected.
Reset button serves to switch off the relay overheating. 5 before the temperature of emergency shutting-down the alarm switches on again. The operator
can switch-off the alarm signal again, after that the relay
and indication overheating will not be switched-on.

Overall and mounting dimensions of the device


Cutout in the panel

13

Indoor installation of the transformer


To provide a good functioning of the transformer at
its indoor installation respect the following conditions:
Distance from the transformer conducting parts t
the wall shall be chosen according to the Operating rules of electrical installations;
Available access for inspection and maintenance of
transformer (including access to the NLTC taps);
The ventilation system of a room shall be of the
required power which provides the extraction of
the transformer heat.
Transformer shall be protected against atmospheric
precipitations, condensate, foreign particles and
objects.

Vntilation
Clculation of the ventilation system includes the
calculation of the air inlet and outlet holes and, if necessary, the power calculation for the forced cooling of
room.

Initial data for the calculation:


sh.c. short-circuit losses of transformer, kWt at
115;
nl no-load losses, kWt
the height difference of the air inlet and outlet
holes, m;
k cfficient, taking into account the protection
class of transformer
Protection class IP00: k=1;
Protection class IP21, IP31: k=0,5.
Surface area of a hole, S, m2 (without surface area
of grids) for the air inlet is calculated according to the
following formula:
sh.c.
sh.c.

nl
nl

Surface area of a hole S1, m2 (without surface area


of grids) for the air inlet is calculated according to the
following formula:
sh.c.

nl

Dimensions of holes, clculated according to the


formulas, will be correct at the average air temperature 20 and height above the
sh.c.seanllevel up to 1000 m.
sh.c.
nl
If its impossible t provide
a required surface area of holes for the ventilation, its necessary to foresee the forced ventilation of the room.
Capacity of the ventilation system, m3/min:
sh.c.

nl

14

Cmpleteness

STANDARD CMPLETENESS:
Together with the transformer the scope of supply
includes:
temperature control device;
4 temperature sensors;
4 pivotal rolls;
the transformer passport, its installation, operation
and maintenance manuals;
the original pckage;
a set of quick-break fuses.
ADDITIONAL CMPLETENESS:
a protective housing;
a set of forced ventilation fans with automatic
devices;
a set of vibration dampers;
a set of current transformers;

15

TESTS

Carried out according to IEC 60076-11 and GS


52719-2007 control, type and special tests confirm
that dry-type transformers correspond to all specified
requirements.
The manufacturing plant can carry out a number
of type and special tests upon additional request. This
opportunity allows to confirm the declared technical
characteristics of the manufactured transformers.
SVEL dry-type transformers correspond to electromagnetic emission norms:
SnPiN 2.1.2.265-10 (sanitary - epidemiological require-

ments to the living conditions in residential buildings and


premises), SnPiN 2.2.2.1191-03 (Electromagnetic fields
in production conditions); nd also noise and vibration
norms: SN 2.2.4/2.1.8562-96 (noise at the workplaces, in
residential and public buildings and residential areas), SN
2.2.4/2.1.8.566-96 (Industrial vibration, and vibration in
residential and public buildings).

16

SERVICE

PCKAGE

Installation supervision (technical manual and


engineering supervision);
After-sales service of the installed transformers
and reactors;
Recommendations on installation;
Service and warranty maintenance, including
warranty repair .

WRRNTY

SVEL Group provides the full quality warranty on


the manufactured equipment:
3 years warranty on dry-type transformers from the
commissioning date;
Service life 30 years.

STORAGE
Before placing the transformer for storage it is necessary to inspect the unharmed package and transformer itself and also to check the completeness of
the supply and to restore the damaged package.
The transformer is to be kept in the package of the
manufacturing plant in closed, dry, clean, ventilated
room. The storage conditions are according to GOST
15150-69.
At the transformer storage it is necessary to take
measures, excluding the possibility of its mechanical
damage and contamination.

All equipment supplied by SVEL Group undergoes


the presale preparation. Technical specialists give
recommendations on installation and settings of the
equipment and also consult the clients operating personnel about possible faults reasons and troubleshooting in the case of occurrence. Transformers are sent to
the customer packed in wooden boxes. he packing
type is chosen depending on the protection requirements against climatic factors , way of transportation
and design features of the transformer.
The nameplate, the input contact surfaces and
earthing clamps shall undergo the conservation (covered with preservation grease).
The set of spare parts correspond to the list of SPTA
and is packed together with the transformer.
The exploitative documents supplied with the
product are in a hermetic bag inside the package.
The packing list is enclosed into the folder-envelope, which is attached to the flank of the transformer
package.

17

RNSPORTION
Transformers are delivered to the Customer by railroad or by
motor transport. It is admitted to transport the transformers by air,
by river boat or sea craft.
Usually transformers are delivered to the Customer being completely assembled or partly dismantled depending on the mass and
overall dimensions.
Right after arrival to the point of destination before the transformer unloading together with the representative of the forwarder it is necessary to inspect the package to be sure in absence of the
mechanical damage.
In case of revealing of any mechanical damage of the transformer it is necessary to draw up a statement of the inspection results
and to address to the manufacturing plant.

Lading-unloading works
Unloading of the transformer shall be carried out with facilities
which loading capacity corresponds to the transformer mass. The
arrangement of strapping is indicated on the transformer package.
To move the transformer without its package its necessary to
use all the lifting lugs at the same time. The arrangement of strapping is indicated on the dimensional drawing.
Transformers despite their solid design can not withstand strong
impacts or jerking via the lifting lugs. When unloading it is recommended to use the appropriate rope, according to the attached
drawing, where level B shall be higher than level A

Transformers are equipped with ground wheels pivotal in two


directions. For dragging, you can use the special lifting lugs which
are near the wheels. If the transformer is not equipped with a pallet, lifting to the electric car can be carried out only in the longitudinal direction.

18

Operation capabilities at the overloads


Life cycle of dry-type transformers is several
decades, but the exact lifetime is rather hard to be
defined as it depends on the operation conditions.

Service life depends n overloads, which the drytype transformer undergoes during its service life. As
a rule the overloads produce heating of windings, that
has negative thermal effect on the insulation and leads
to its thermal wear.
Transformer can work with the presence of some
overloads which dont influence its service life. Its
possible when normal load is less than rated load.
Admissible loads (2) are limited by time (tp) acording
to the previous functional indicator (cefficient of the
previous load, 1) and depend n the average environmental indicator 0.

Transformer is designed taking into account its


operation under the rated power and at the normal
ambient temperature according to IEC 60726:
ximum temperature 40
Daily average temperature 30
Average annual temperature 20
If not specified otherwise, initial temperature is
considered to be the average annual temperature of
20.
Transformer, designed for operation at the average
annual temperature of 20, can be also used at higher
or lower temperatures, with increasing or decreasing
of power according to the following parameters:
Average annual
temperature:

Pwer
(% to nom)

-10C

116 %

0C

110 %

10C

104 %

20C

100 %

25C

97 %

30C

94 %

35C

90 %

ambient temperature;
initial load;
nominal

nominal

load duration, tp, h;

load current;

the maximum time specified load current K2, h.

19

The main characteristics of transformer


On-load losses, Wt
Pwer, kV

115C

No-load losses,
Wt

75C

25

530

550

470

490

180

40

730

760

650

680

220

63

1160

1200

1020

1060

275

100

1400

1450

1230

1280

390

160

2410

2500

2130

2210

550

250

3080

3200

2720

2830

700

400

4330

4500

3830

3980

1000

630

7200

7700

6380

6800

1150

1000

9700

10200

8590

9000

1550

1250

11000

11700

9750

10350

2300

1600

13100

13900

11600

12300

2500

2000

15400

16300

13600

14400

2850

2500

19500

20900

17200

18500

3200

3200

24800

26300

21950

23300

5200

4000

26000

27500

24350

24350

5900

Notes:
1) for transformers of the power over 4000 kV th main characteristics are to be agreed upon additionally;
2) th main characteristics of transformers of voltage classes 15-35 kV are to be agreed upon the clients individual request.

20

The main characteristics of series transformers


1
2

1
23

Dimensions, mm

Pwer,
kV

Z1 x Z2

Mass not
more, kg

25

880

520

805

290

520

740

75

205

155

220

420 420

380

40

940

520

835

305

535

770

75

210

155

225

420 420

440

63

950

520

925

310

625

845

75

205

155

225

420 420

500

100

1050

620

1025

350

705

1020

75

215

160

255

520 520

690

160

1060

620

1145

365

755

1070

75

225

170

285

720 520

790

250

1135

620

1215

385

815

1120

75

240

185

270

720 520

930

400

1280

770

1350

435

925

1245

75

255

200

295

840 670

1500

630

1450

770

1445

490

970

1345

75

275

220

345

840 670

1950

1000

1570

970

1640

530

1125 1530

75

300

240

385

1070 820

2700

1250

1660

970

1760

565

1240 1640

75

295

235

380

1070 820

3180

1600

1730 1100 1855

580

1305 1730

75

310

250

390

1070 820

3790

2000

1825 1270 2025

620

1455 1895

90

320

260

410

1070 1070

4470

2500

2000 1270 2160

650

1600 2010

90

350

285

400

1070 1070

5270

3200

2285 1500 2450

770

1780 2300

90

395

300

480

1300 1300

7950

For transformers of the power over 3200 kV the overall dimensions are to be agreed upon additionally.

21

Overall installation dimensions of series transformers with


the side lcation of inputs (left and right design version)
example of left design version

Z1 x Z2

Dimensions, mm
Mass
not
more, kg
L
B
H
Z1 x Z2
100
1560
820
1340
520 520
780
160
1720
880
1385
720 520
930
250
1720
880
1410
720 520
1100
400
1905
980
1650
840 670
1730
630
1995
980
1900
840 670
2200
1000
2145
1055
1985
1070 820
2890
1250
2390
1080
2100
1070 820
3365
1600
2465
1180
2115
1070 820
3830
2000
2665
1270
2350
1070 1070
4600
2500
2825
1270
2655
1070 1070
5700
3200
3255
1580
2890
1300 1300
8780
For transformers of the power over 3200 kV the overall dimensions are to be agreed upon additionally.

Pwer, kV

22

Overall installation dimensions of series transformers with


location of the HV and LV windings inputs on the upper cover

Z1 x Z2

Dimensions, mm
Mass
not more, kg
L
B
H
Z1 x Z2
160
1420
880
1565
720 520
930
250
1420
880
1565
720 520
1100
400
1520
980
1795
840 670
1700
630
1630
980
2015
840 670
2080
1000
1780
1050
2160
1070 820
2860
1250
2040
1180
2245
1070 820
3440
1600
2040
1180
2245
1070 820
3650
2000
2250
1270
2470
1070 1070
4660
2500
2400
1270
2770
1070 1070
5780
3200
2870
1580
3010
1300 1300
8850
For transformers of the power over 3200 V the overall dimensions are to be agreed upon additionally.

Pwer, kV

23

Overall installation dimensions of series transformers


rated 25-250 KV (dsign version: LV and V windings inputs - down)

Dimensions, mm
Mass
not more, kg
L
B
H
Z1 x Z2
25
1120
830
1020
420 420
410
40
1120
830
1020
420 420
490
63
1120
830
1020
420 420
580
100
1260
820
1340
520 520
780
160
1420
880
1390
720 520
910
250
1420
880
1410
720 520
1100
For transformers of the power over 250 V the overall dimensions are to be agreed upon additionally.

Pwer, kV

24

NOTE:

25

Questionnaire
Cmpany: _______________________________________________
_______________________________________________________
l:____________________________________________________
Fax:____________________________________________________
E-mail:__________________________________________________

p/b 242, Pervoi Pjatiletki sq.,


Yekaterinburg 620012, Russia
l: +7 (343) 253-50-21
Fx: +7 (343) 253-50-12
E-mail: sale@svel.ru
www.svel.ru

CAST RESIN DRY-TYPE CONVERTER RANSFORMER


chnical data of transformer (type):
Purpose:
Rated pwer:
25

40

63 100 160 250 400 630 1000 1250 1600 2000 2500 3200 4000 6300 10000

MV winding (kV):

HV winding (kV0:

6
10
35

Winding connecon group: Short-circuit voltage,%:

0,4
0,69

/-11
/-0

4
6
8

Off-load tap changer,%: The installaon height


above the sea level, m:
22,5
<1000

Cmposion
of the highest harmonics:

Recfied vltag Ud, B:

Overcurrent class according to GOST 16772:

Recfied current ld, A:

Climac modifiicaon and placement category:


1
moderate climate
2
moderate cold climate
3
tropical climate

Protecon class IP:


IP00
IP21
IP33

Front side
(Rang plate side)

Version of inputs:
l
MV, HV windings - up
without busbars (for IP00)

right
right mirrr

Front side
(Rang plate side)

Addional requirements to the operaon condion and completness:

Number:
Delivery date:

The questionnaire is to be sent by fax: +7 (343) 253-50-12

26

Questionnaire
Cmpany: _______________________________________________
_______________________________________________________
l:____________________________________________________
Fax:____________________________________________________
E-mail:__________________________________________________

p/b 242, Pervoi Pjatiletki sq.,


Yekaterinburg 620012, Russia
l: +7 (343) 253-50-21
Fx: +7 (343) 253-50-12
E-mail: sale@svel.ru
www.svel.ru

CAST RESIN DRY-TYPE POWER RANSFORMER


chnical data of transformer (type):
Rated pwer (kV):
25

40

63 100 160 250 400 630 1000 1250 1600 2000 2500 3200 4000 6300 10000

HV winding (kV):

LV winding (kV):

6
10
35

0,4
0,69

Short-circuit voltage, %:

Off-load tap changer, %:

4
6
8

22,5

Climac modifiicaon and placement category:


1
moderate climate
2
moderate cold climate
3
tropical climate

Winding connecon group:


/n-11
/n-0

The installaon height (above the sea level), m:


<1000

Protecon class IP:


IP00
IP21
IP33

Front side
(Rang plate side)

Version of inputs:
l
MV, HV windings - up
without busbars (for IP00)

Front side
(Rang plate side)

Addional requirements to the operaon condion and completness:

Number:
Delivery date:

The questionnaire is to be sent by fax: +7 (343) 253-50-12

27

High energy efficiency

Higher cost effectiveness

Environmental care

Wrranty srvice

Increased service life

Team of professionals

Headquarters
61, Chernyakhovsky st., Yekaterinburg 620010, Russia
l.: +7 (343) 253-50-13
Fx: +7 (343) 253-50-18
www.svel.ru
sale@svel.ru

Branch Offices
scow
office 114, sector 2, building , 11a Derbenevskaya quay,
scow 115114, Russia
l./fx: +7 (495) 913-89-00, 913-89-11
msk@svel.ru
iv
705, 11, Ruskovoy st., iv 02660, Ukraine
l.: +38 (044) 581-57-50
kiev@svel.ru
stn
office 804, 33 D.nv st., Esil district,
Astana 010000, Kazakhstan
l.: +7 (7172) 73-81-24, 73-81-25.
Fx: +7 (7172) 73-81-26
kz@svel.ru

Remark:
In connection with a constant improvement we retain the
right to make changes and technical corrections of the given
document without previous notice
For detailed information please contact our experts.